Calibration of Measured Time Values between Network Elements
draft-contreras-bpm-calibration-00
This document is an Internet-Draft (I-D).
Anyone may submit an I-D to the IETF.
This I-D is not endorsed by the IETF and has no formal standing in the
IETF standards process.
| Document | Type | Active Internet-Draft (individual) | |
|---|---|---|---|
| Authors | Luis M. Contreras , Adilson Bazan Fernandes | ||
| Last updated | 2026-11-02 | ||
| Replaces | draft-contreras-bmp-calibration | ||
| RFC stream | (None) | ||
| Intended RFC status | (None) | ||
| Formats | |||
| Stream | Stream state | (No stream defined) | |
| Consensus boilerplate | Unknown | ||
| RFC Editor Note | (None) | ||
| IESG | IESG state | I-D Exists | |
| Telechat date | (None) | ||
| Responsible AD | (None) | ||
| Send notices to | (None) |
draft-contreras-bpm-calibration-00
bpm L. Contreras
Internet-Draft A. Bazan
Intended status: Informational Telefonica
Expires: 6 May 2027 2 November 2026
Calibration of Measured Time Values between Network Elements
draft-contreras-bpm-calibration-00
Abstract
Network devices are incorporating capabilities for time stamping
certain packets so that such time stamps can reference the time at
which a packet passes through a given device (at ingress or egress).
Those stamps or marks are relevant to calculating the measured delay
and can be used for traffic engineering purposes.
To ensure consistency and accuracy across different network element
implementations, a benchmarking procedure is necessary to calibrate
the timestamps. Such a procedure can permit the identification and
correction of any deviations or biases in the time stamps produced by
diverse devices. This document proposes a methodology for
Calibrating the measurements from different network element
implementations in a common measurement scenario.
Status of This Memo
This Internet-Draft is submitted in full conformance with the
provisions of BCP 78 and BCP 79.
Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF). Note that other groups may also distribute
working documents as Internet-Drafts. The list of current Internet-
Drafts is at https://datatracker.ietf.org/drafts/current/.
Internet-Drafts are draft documents valid for a maximum of six months
and may be updated, replaced, or obsoleted by other documents at any
time. It is inappropriate to use Internet-Drafts as reference
material or to cite them other than as "work in progress."
This Internet-Draft will expire on 6 May 2027.
Copyright Notice
Copyright (c) 2026 IETF Trust and the persons identified as the
document authors. All rights reserved.
Contreras & Bazan Expires 6 May 2027 [Page 1]
Internet-Draft Time measurement calibration November 2026
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents (https://trustee.ietf.org/
license-info) in effect on the date of publication of this document.
Please review these documents carefully, as they describe your rights
and restrictions with respect to this document. Code Components
extracted from this document must include Revised BSD License text as
described in Section 4.e of the Trust Legal Provisions and are
provided without warranty as described in the Revised BSD License.
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . 2
2. Baseline measurement scenario . . . . . . . . . . . . . . . . 4
3. Network Element Calibration Tests . . . . . . . . . . . . . . 4
3.1. Single network element test . . . . . . . . . . . . . . . 5
3.2. Paired network elements test . . . . . . . . . . . . . . 6
3.3. Measurement conditions . . . . . . . . . . . . . . . . . 6
3.4. Resolution of the calibration process . . . . . . . . . . 7
3.5. Repeatability and Stability Assessment . . . . . . . . . 8
3.6. Calibration Under Operational Load Conditions . . . . . . 8
4. Further discussions . . . . . . . . . . . . . . . . . . . . . 9
4.1. Consideration of hybrid methods (e.g., IOAM) as measurement
mechanisms for calibration assessment . . . . . . . . . . 9
4.2. Usage of instrumentation instead of physical fiber spools
for determining the baseline value . . . . . . . . . . . 9
4.3. Cross-Method Validation . . . . . . . . . . . . . . . . . 10
5. References . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.1. Normative References . . . . . . . . . . . . . . . . . . 10
5.2. Informative References . . . . . . . . . . . . . . . . . 11
Appendix A. Measurement data normalization . . . . . . . . . . . 12
Appendix B. Calibration Considerations for Link Aggregation Groups
(LAGs) . . . . . . . . . . . . . . . . . . . . . . . . . 13
Acknowledgements . . . . . . . . . . . . . . . . . . . . . . . . 13
Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . . 13
1. Introduction
Latency is becoming one of the major drivers for network traffic
engineering and planning due to the introduction of novel services
sensitive to both latency and its variability.
Network devices incorporate capabilities for time-stamping certain
packets so that such time stamps can reference the time at which a
packet passes through a given device (at ingress or egress). Those
stamps or marks are relevant to calculating the measured delay and
can be used for traffic engineering purposes. That is the case of
the Flex Algo algorithms [RFC9502] [RFC9351] aiming to represent low
latency topologies being based on the time reference measured among
Contreras & Bazan Expires 6 May 2027 [Page 2]
Internet-Draft Time measurement calibration November 2026
devices. Furthermore, services sensitive to latency, such as the
deterministic ones [RFC8557] or those following the network slicing
paradigm [RFC9543], require from accurate information in order to
place flows in the network.
The measurements here considered are those performed between neighbor
nodes in a network, so that an end-to-end delay metric can be
composed by aggregating partial measurements. To ensure consistency
and accuracy across different network element implementations, a
benchmarking procedure is necessary to calibrate the timestamps.
This allows correction of observed measurements and improves the
reliability of latency-based traffic engineering decisions.
Different protocols are implemented nowadays on network devices to
perform such measurements, such as TWAMP-light [RFC5357] [RFC8545] or
STAMP [RFC8972]. It is then important to ensure that the time stamp
produced by the network device is accurate so that the traffic
engineering decisions based on such measurements are correct.
Differences in timestamp generation architecture may introduce
systematic offsets and bias that affect measurement accuracy.
Differences on accuracy of the measurements among devices can be due
to different causes, such as different solutions for time stamping
(e.g., hardware-based vs software-based), different module involved
in the time stamping process (e.g., central processor vs line card),
different type of component taking care of the timestamping (e.g.,
Network Processor, ASIC, hardware accelerator, etc), etc.
The traffic engineering decisions will be typically implemented by
centralized controllers, which can process the measurements and
decide on the specific traffic engineering path. This can be the
case of the Path Computing Element (PCE) [RFC5440]. It is important
to note that any deviations or bias on the time stamps of the packets
can lead to inaccurate calculations or decisions.
An example is the following: Network Device A can introduce some
delay (e.g., due to less powerful processing capabilities) in the
timestamp versus Network Device B. In a dual-plane backbone, with
similar characteristics in terms of physical path length, where one
of the planes is built with network devices of type A while the other
one is built with network devices of type B, the difference between
the time stamps in A and B can lead to all the traffic being
delivered by one of the planes. This is the case, for instance, in a
dual-connect architecture enabling MPLS and SRv6 coexistence with
Flex-Algo, operating over protected IP Backbone paths with identical
physical path lengths. In this scenario hardware heterogeneity can
introduce measurement asymmetries. Discrepancies in the timestamp
processing capabilities implemented in the two types of network
devices may occur. If a low-latency Flex-Algo topology is deployed
Contreras & Bazan Expires 6 May 2027 [Page 3]
Internet-Draft Time measurement calibration November 2026
and used for traffic engineering, this measurement offset can
artificially skew the metric calculation, causing the path
computation to steer the traffic exclusively over certain paths,
thereby impacting the expected policy load distribution or path
protection.
The purpose of this document is to present a benchmarking procedure
to calibrate the time stamps of different network device
implementations so that the observed measured can be corrected if
needed during the processing of the measured time-stamped data.
2. Baseline measurement scenario
In order to create a reference or baseline to later on compare the
measurements obtained from distinct network elements, a reference
scenario is defined. This reference scenario will serve to calibrate
the time stamps of the different network devices.
The reference scenario assume an instrumentation device generating
and receiving TWAMP-light or STAMP packets. Those packets are
delivered on a fiber spool of a given known length, L. Typical
lengths for testing purposes are in the order of 20 - 100 kms. It
can be assumed a delay of 5 us/km on that fiber spool [ITU-T-G.114].
The measurement setup is as follows:
+------------+
| |
+------------| tester |<-------------+
| | | |
| +------------+ |
| |
| |
| Fiber spool of length L |
+----------------------------------------+
Figure 1: Baseline measurement scenario
The tester will generate the baseline measurement for the time spent
on delivering packets through the link represented by the fiber
spool. Such a reference value can be defined as T_baseline and will
serve for comparison of the measurements performed by the distinct
implementations of network elements for calibration purposes.
3. Network Element Calibration Tests
As in the baseline scenario described previously, equivalent
calibration procedures can be performed using actual network
elements. The following test scenarios are considered.
Contreras & Bazan Expires 6 May 2027 [Page 4]
Internet-Draft Time measurement calibration November 2026
* Single network element test, performing the test with just one
single network element, similar to the baseline scenario. This
kind of test can be useful for characterizing the behavior of one
specific network device implementation, including both its
hardware and software components.
* Paired network element test, performing the test between two
network elements. This can be useful for determining interworking
scenarios, considering either network elements from the same
vendor but with different characteristics (e.g., network device
model, hardware or software characteristics, etc), or network
elements from different vendors.
3.1. Single network element test
The scenario is similar to the baseline scenario, as follows.
+------------+
| Network |
+------------| Element |<-------------+
| | A | |
| +------------+ |
| |
| |
| Fiber spool of length L |
+----------------------------------------+
Figure 2: Single network element test
As before, the network element generates measurement packets through
the link represented by the fiber spool. The obtained value can be
referred as T_ne.
The calibration exercise results from the comparison between
T_baseline and T_ne. Thts is, the difference between T_ne and
T_baseline provides an indication of the measurement accuracy and
potential timestamping bias associated with the network element under
test.
The characteristics of both ports and line cards used to terminate
the fiber spool may influence the observed measurements. Different
hardware implementations can introduce additional latency or
timestamping variations. Therefore, calibration tests should
document the specific interface and line card used during the
measurement process.
Contreras & Bazan Expires 6 May 2027 [Page 5]
Internet-Draft Time measurement calibration November 2026
3.2. Paired network elements test
This scenario considers the measurement to be performed between a
pair of network elements, as follows.
+------------+ +------------+
| Network | Fiber spool of length L | Network |
| Element |<----------------------->| Element |
| A | | B |
+------------+ +------------+
Figure 3: Paired network elements test
The network elements may belong to the same or different vendor. The
purpose of this test is to calibrate in interoperability scenarios
where the the devices involved represent different implementations of
the same network device functionality, including the protocols used
for time stamping.
In this case, one of the network elements generates measurement
packets over the link represented by the fiber spool of known length
(and previously measured in the reference scenario). The value
obtained from the measurement packets from Network Element A to
Network Element B can be referred as T_ne_ab. Similarly, it is
possible to obtain T_ne_ba on the other direction.
The calibration procedure consists of comparing the measured values
against the baseline reference value T_baseline.
Assuming that both T_ne_ab and T_ne_ba produce the same result, the
calibration exercise results from the comparison between T_baseline
and T_ne_ab (or T_ne_ba). Whatever observed deviation will provide
an indication of the combined effect of the measurement accuracy and
timestamping characteristics of the network elements participating in
the test.
On the other hand, differences observed between T_ne_ab and T_ne_ba
may indicate asymmetric forwarding behavior, differences in timestamp
generation mechanisms, synchronization inaccuracies, or
implementation-specific characteristics affecting the measurement
process.
3.3. Measurement conditions
The measurements defined in this document should specify the
following information:
Contreras & Bazan Expires 6 May 2027 [Page 6]
Internet-Draft Time measurement calibration November 2026
* Network device model, including a description of the hardware and
software version used during the test.
* Length of the fiber spool used as calibration reference for the
measurement.
* Description of the ports and line card where the fiber spool is
connected, since different line cards could produce measurements
with different accuracy levels.
* Protocol used in the measurement (e.g., TWAMP-light, STAMP, ...).
* Clock source (e.g., GNSS, PTP, SyncE, NTP, holdover, etc).
* Duration of the test for statistical consistency (e.g., period for
average, min, max calculations)
* Network tester or instrumentation used for generating the baseline
values.
In addition, if available, the exact timestamp insertion point is of
interest since this information is relevant for interpreting
differences observed implementations and hardware architectures. For
instance, insertion points such as Network Processing Unit (NPU),
forwarding ASIC, line card CPU, route processor, etc.
(Note: to consider scalability aspects on the collected measurements
that could impact the calibration exercise. For instance, if
multiple sessions are running in parallel from one node to several
neighbor nodes, with one session per neighbor).
3.4. Resolution of the calibration process
The calibration process of the time-stamps observed during the
benchmarking methodology needs to take into account the time units of
relevance for the purpose of the usage of such measurements.
The timestamp format used in TWAMP, TWAMP Light, and STAMP protocols
is based on the NTP format, as defined in [RFC8877]. These protocols
employ a 64-bit timestamp, where:
* The first 32 bits represent the number of seconds since the NTP
epoch (January 1, 1900)
* The remaining 32 bits represent fractional seconds.
This structure provides a theoretical resolution of approximately 233
picoseconds.
Contreras & Bazan Expires 6 May 2027 [Page 7]
Internet-Draft Time measurement calibration November 2026
For instance, with this in mind, if the purpose is the generation of
FlexAlgo topologies based on delay, it should be taken into account
that the delay field advertised when using IS-IS [RFC8570] or OSPF
[RFC7471] is expressed in microseconds. Thus, differences below a
microsecond are not relevant. OSPF or IS-IS with traffic engineering
extensions encode the "delay" value in microseconds using 24-bit
fields. This naturally results in lower precision compared to the
timestamp format used in active measurement protocols.
When calibrating measurements for use in network operations or
control plane mechanisms, it is crucial to consider the specific use
case of the timestamp to ensure appropriate granularity and accuracy.
For example, in the case of constructing low-latency FlexAlgo
topologies, it is necessary to align the measurement resolution to
microseconds, as this is the resolution that the IGP protocol can
propagate towards the control plane generating the low-latency
topology. To achieve this, the measured delay collected by means of
TWAMP, TWAMP Light, and STAMP protocols SHOULD be adjusted using a
ceiling function, i.e., rounding up to the nearest integer value in
microseconds.
Other use cases, however, may require different resolution levels,
rounding techniques, or adjustments depending on operational goals.
3.5. Repeatability and Stability Assessment
Repeatability is relevant in order to provide a more complete
characterization of the calibration process. Accuracy obtained from
a single execution does not guarantee the temporal consistency of the
measurementa. The calibration process MUST include repeatability
tests intended to evaluate the stability of the measurement results
over time. This is related to the number of independent measurement
runs and the number of samples per measurement run.
3.6. Calibration Under Operational Load Conditions
Results obtained under idle or low-load conditions may not accurately
represent the behavior of a network element operating in production
environments. Factors such as increased CPU utilization, buffer
occupancy, forwarding pipeline congestion, and telemetry processing
overhead can affect timestamp generation and measurement accuracy.
Therefore, the calibration process SHOULD be repeated under different
levels of operational load in order to evaluate the stability and
accuracy of the measurement system under realistic operating
conditions.
The following load levels are RECOMMENDED:
Contreras & Bazan Expires 6 May 2027 [Page 8]
Internet-Draft Time measurement calibration November 2026
+------------+----------------------+
| Condition | Resource Utilization |
+------------+----------------------+
| Idle | 0% |
| Low | 25% |
| Medium | 50% |
| High | 75% |
| Saturation | 95% |
+------------+----------------------+
The characteristics of the background traffic used to generate the
load on the link SHOULD be documented as part of the calibration
report.
4. Further discussions
This is a placeholder for capturing topics that will be considered
for next versions of the document.
4.1. Consideration of hybrid methods (e.g., IOAM) as measurement
mechanisms for calibration assessment
On-path hybrid methods, such as In situ Operations, Administration,
and Maintenance (IOAM) [RFC9197] [RFC9326] allow the obtention of
telemetry information that can be used for measuring delays in
network links. The IOAM data can be embedded in different
encapsulations.
While these methods coud be used for collecting the metric of
interest, in the context of calibrating hop-by-hop measurements, it
would impose practical limitations. For instance, the need of
generating individual flows per hop for the solely purpose of
measuring the link delay. Furthermore, it would require the
specification of the measurement conditions in terms of the flows
used for embedding the telemetry data.
4.2. Usage of instrumentation instead of physical fiber spools for
determining the baseline value
Instrumentation equipment can introduce impairments in a link in a
controlled manner, either as a deterministic or statistical manner.
For the purpose of the calibration pursued in this document, the
usage of instrumentation equipment can be considered instead of
physical fiber spools by configuring deterministic delay values.
While this can be a proper approach, it presents some practical
shortcomings. For instance, the need of supporting all the variety
of interface bit rates of interest in the platforms to be calibrated.
Contreras & Bazan Expires 6 May 2027 [Page 9]
Internet-Draft Time measurement calibration November 2026
4.3. Cross-Method Validation
Multiple measurement solutions may coexist within the same
operational environment. Differences in measurement collection,
processing methodologies, timestamp generation mechanisms per
solution, and data aggregation techniques may result in systematic
deviations between different measurement methods.
The objective of this analysis is to determine the level of
convergence between different measurement methodologies and to
identify potential systematic deviations among implementations of the
different measurement solutions.
5. References
5.1. Normative References
[RFC5357] Hedayat, K., Krzanowski, R., Morton, A., Yum, K., and J.
Babiarz, "A Two-Way Active Measurement Protocol (TWAMP)",
RFC 5357, DOI 10.17487/RFC5357, October 2008,
<https://www.rfc-editor.org/info/rfc5357>.
[RFC5440] Vasseur, JP., Ed. and JL. Le Roux, Ed., "Path Computation
Element (PCE) Communication Protocol (PCEP)", RFC 5440,
DOI 10.17487/RFC5440, March 2009,
<https://www.rfc-editor.org/info/rfc5440>.
[RFC7471] Giacalone, S., Ward, D., Drake, J., Atlas, A., and S.
Previdi, "OSPF Traffic Engineering (TE) Metric
Extensions", RFC 7471, DOI 10.17487/RFC7471, March 2015,
<https://www.rfc-editor.org/info/rfc7471>.
[RFC8545] Morton, A., Ed. and G. Mirsky, Ed., "Well-Known Port
Assignments for the One-Way Active Measurement Protocol
(OWAMP) and the Two-Way Active Measurement Protocol
(TWAMP)", RFC 8545, DOI 10.17487/RFC8545, March 2019,
<https://www.rfc-editor.org/info/rfc8545>.
[RFC8570] Ginsberg, L., Ed., Previdi, S., Ed., Giacalone, S., Ward,
D., Drake, J., and Q. Wu, "IS-IS Traffic Engineering (TE)
Metric Extensions", RFC 8570, DOI 10.17487/RFC8570, March
2019, <https://www.rfc-editor.org/info/rfc8570>.
[RFC8972] Mirsky, G., Min, X., Nydell, H., Foote, R., Masputra, A.,
and E. Ruffini, "Simple Two-Way Active Measurement
Protocol Optional Extensions", RFC 8972,
DOI 10.17487/RFC8972, January 2021,
<https://www.rfc-editor.org/info/rfc8972>.
Contreras & Bazan Expires 6 May 2027 [Page 10]
Internet-Draft Time measurement calibration November 2026
[RFC9197] Brockners, F., Ed., Bhandari, S., Ed., and T. Mizrahi,
Ed., "Data Fields for In Situ Operations, Administration,
and Maintenance (IOAM)", RFC 9197, DOI 10.17487/RFC9197,
May 2022, <https://www.rfc-editor.org/info/rfc9197>.
[RFC9326] Song, H., Gafni, B., Brockners, F., Bhandari, S., and T.
Mizrahi, "In Situ Operations, Administration, and
Maintenance (IOAM) Direct Exporting", RFC 9326,
DOI 10.17487/RFC9326, November 2022,
<https://www.rfc-editor.org/info/rfc9326>.
[RFC9351] Talaulikar, K., Ed., Psenak, P., Zandi, S., and G. Dawra,
"Border Gateway Protocol - Link State (BGP-LS) Extensions
for Flexible Algorithm Advertisement", RFC 9351,
DOI 10.17487/RFC9351, February 2023,
<https://www.rfc-editor.org/info/rfc9351>.
[RFC9502] Britto, W., Hegde, S., Kaneriya, P., Shetty, R., Bonica,
R., and P. Psenak, "IGP Flexible Algorithm in IP
Networks", RFC 9502, DOI 10.17487/RFC9502, November 2023,
<https://www.rfc-editor.org/info/rfc9502>.
[RFC9534] Li, Z., Zhou, T., Guo, J., Mirsky, G., and R. Gandhi,
"Simple Two-Way Active Measurement Protocol Extensions for
Performance Measurement on a Link Aggregation Group",
RFC 9534, DOI 10.17487/RFC9534, January 2024,
<https://www.rfc-editor.org/info/rfc9534>.
5.2. Informative References
[ITU-T-G.114]
"One-way transmission time", May 2003.
[RFC8557] Finn, N. and P. Thubert, "Deterministic Networking Problem
Statement", RFC 8557, DOI 10.17487/RFC8557, May 2019,
<https://www.rfc-editor.org/info/rfc8557>.
[RFC8877] Mizrahi, T., Fabini, J., and A. Morton, "Guidelines for
Defining Packet Timestamps", RFC 8877,
DOI 10.17487/RFC8877, September 2020,
<https://www.rfc-editor.org/info/rfc8877>.
[RFC9543] Farrel, A., Ed., Drake, J., Ed., Rokui, R., Homma, S.,
Makhijani, K., Contreras, L., and J. Tantsura, "A
Framework for Network Slices in Networks Built from IETF
Technologies", RFC 9543, DOI 10.17487/RFC9543, March 2024,
<https://www.rfc-editor.org/info/rfc9543>.
Contreras & Bazan Expires 6 May 2027 [Page 11]
Internet-Draft Time measurement calibration November 2026
Appendix A. Measurement data normalization
As part of the comparison of the measurements produced by different
implementations, a data normalization process could be required. The
goal is to ensure that functionally equivalent metrics can be
compared consistently in multivendor scenarios. The reason for it is
that network elements from different vendors can use distinct metric
names, units of measurement, temporal granularities, timestamp
formats, and statistical methodologies to represent equivalent
performance indicators.
Such normalization process can imply the mapping of equivalent
metrics, the conversion of reported units, the temporal granularity
considered, the aligment of the statistical window used and the
normalization of the timestamp format.
The objective of metric normalization is to ensure that equivalent
measurements collected from heterogeneous implementations are
interpreted and processed in a consistent manner.
An example of metric normalization is shown below:
+----------+------------------+----------------+
| Vendor | Native Metric | Normalized KPI |
+----------+------------------+----------------+
| Nokia | round-trip-delay | RTT |
| Cisco | network-delay | RTT |
| HPE | rtt-average | RTT |
| Huawei | delay-average | RTT |
+----------+------------------+----------------+
Once calibrated, normalized measurement data may be subsequently
exported to observability platforms, analytics systems, Software-
Defined Networking (SDN) controllers, automation frameworks, and data
lake environments.
This procedure can lead to accurate comparisons, consistent
performance assessments, and correct Traffic Engineering decisions in
multivendor operational environments.
Contreras & Bazan Expires 6 May 2027 [Page 12]
Internet-Draft Time measurement calibration November 2026
Appendix B. Calibration Considerations for Link Aggregation Groups
(LAGs)
Link Aggregation Groups (LAGs) are widely deployed in operational
networks to increase available bandwidth and provide resiliency
through the use of multiple physical links presented as a single
logical interface. Although LAG member links are treated by the
control plane as a single logical resource, individual member links
may exhibit different performance characteristics, including
variations in delay, packet loss, delay variation, and utilization.
Performance differences among member links of the same LAG may occur
due to different reasons, like different physical link lengths,
intermittent failures affecting individual member links, etc. As
consequence of that, measurements performed exclusively on the
aggregated LAG may hide degradations affecting individual member
links. [RFC9534] defines extensions to the Simple Two-Way Active
Measurement Protocol (STAMP) that enable performance measurements on
individual LAG member links through the use of micro sessions. These
extensions allow measurement sessions to be associated with specific
physical member links, enabling independent assessment of the
performance of each member within the aggregation group.
When the network element under test utilizes LAGs, the calibration
process SHOULD evaluate each member link individually. The purpose
of this is to identify performance differences among individual
member links that may not be observable when measurements are
performed exclusively on the aggregated logical interface.
Measurement results SHOULD be reported individually for each member
link prior to the calculation or presentation of aggregated LAG
statistics. The calibration report SHOULD identify the member link
associated with each measurement and document any observed
differences among members.
Acknowledgements
The author would like to thank Miguel Cros (Telefonica) for the
discusions on the topic. Moreover the author would like also thank
Giuseppe Fioccola, Tal Mizrahi, Carsten Rossenhoevel for the valuable
comments received during the BMWG meetings.
This work has been partially funded by the European Commission
through the Horizon Europe SNS JU PREDICT-6G project (GA 101095890).
Authors' Addresses
Contreras & Bazan Expires 6 May 2027 [Page 13]
Internet-Draft Time measurement calibration November 2026
Luis M. Contreras
Telefonica
Ronda de la Comunicacion, s/n
28050 Madrid
Spain
Email: luismiguel.contrerasmurillo@telefonica.com
Adilson Bazan
Telefonica
Sao Paulo-
Brazil
Email: adilson.fernandes@telefonica.com
Contreras & Bazan Expires 6 May 2027 [Page 14]