bpm                                                         L. Contreras
Internet-Draft                                                  A. Bazan
Intended status: Informational                                Telefonica
Expires: 6 May 2027                                      2 November 2026

      Calibration of Measured Time Values between Network Elements
                   draft-contreras-bpm-calibration-00

Abstract

   Network devices are incorporating capabilities for time stamping
   certain packets so that such time stamps can reference the time at
   which a packet passes through a given device (at ingress or egress).
   Those stamps or marks are relevant to calculating the measured delay
   and can be used for traffic engineering purposes.

   To ensure consistency and accuracy across different network element
   implementations, a benchmarking procedure is necessary to calibrate
   the timestamps.  Such a procedure can permit the identification and
   correction of any deviations or biases in the time stamps produced by
   diverse devices.  This document proposes a methodology for
   Calibrating the measurements from different network element
   implementations in a common measurement scenario.

Status of This Memo

   This Internet-Draft is submitted in full conformance with the
   provisions of BCP 78 and BCP 79.

   Internet-Drafts are working documents of the Internet Engineering
   Task Force (IETF).  Note that other groups may also distribute
   working documents as Internet-Drafts.  The list of current Internet-
   Drafts is at https://datatracker.ietf.org/drafts/current/.

   Internet-Drafts are draft documents valid for a maximum of six months
   and may be updated, replaced, or obsoleted by other documents at any
   time.  It is inappropriate to use Internet-Drafts as reference
   material or to cite them other than as "work in progress."

   This Internet-Draft will expire on 6 May 2027.

Copyright Notice

   Copyright (c) 2026 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

Contreras & Bazan          Expires 6 May 2027                   [Page 1]
Internet-Draft        Time measurement calibration         November 2026

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents (https://trustee.ietf.org/
   license-info) in effect on the date of publication of this document.
   Please review these documents carefully, as they describe your rights
   and restrictions with respect to this document.  Code Components
   extracted from this document must include Revised BSD License text as
   described in Section 4.e of the Trust Legal Provisions and are
   provided without warranty as described in the Revised BSD License.

Table of Contents

   1.  Introduction  . . . . . . . . . . . . . . . . . . . . . . . .   2
   2.  Baseline measurement scenario . . . . . . . . . . . . . . . .   4
   3.  Network Element Calibration Tests . . . . . . . . . . . . . .   4
     3.1.  Single network element test . . . . . . . . . . . . . . .   5
     3.2.  Paired network elements test  . . . . . . . . . . . . . .   6
     3.3.  Measurement conditions  . . . . . . . . . . . . . . . . .   6
     3.4.  Resolution of the calibration process . . . . . . . . . .   7
     3.5.  Repeatability and Stability Assessment  . . . . . . . . .   8
     3.6.  Calibration Under Operational Load Conditions . . . . . .   8
   4.  Further discussions . . . . . . . . . . . . . . . . . . . . .   9
     4.1.  Consideration of hybrid methods (e.g., IOAM) as measurement
           mechanisms for calibration assessment . . . . . . . . . .   9
     4.2.  Usage of instrumentation instead of physical fiber spools
           for determining the baseline value  . . . . . . . . . . .   9
     4.3.  Cross-Method Validation . . . . . . . . . . . . . . . . .  10
   5.  References  . . . . . . . . . . . . . . . . . . . . . . . . .  10
     5.1.  Normative References  . . . . . . . . . . . . . . . . . .  10
     5.2.  Informative References  . . . . . . . . . . . . . . . . .  11
   Appendix A.  Measurement data normalization . . . . . . . . . . .  12
   Appendix B.  Calibration Considerations for Link Aggregation Groups
           (LAGs)  . . . . . . . . . . . . . . . . . . . . . . . . .  13
   Acknowledgements  . . . . . . . . . . . . . . . . . . . . . . . .  13
   Authors' Addresses  . . . . . . . . . . . . . . . . . . . . . . .  13

1.  Introduction

   Latency is becoming one of the major drivers for network traffic
   engineering and planning due to the introduction of novel services
   sensitive to both latency and its variability.

   Network devices incorporate capabilities for time-stamping certain
   packets so that such time stamps can reference the time at which a
   packet passes through a given device (at ingress or egress).  Those
   stamps or marks are relevant to calculating the measured delay and
   can be used for traffic engineering purposes.  That is the case of
   the Flex Algo algorithms [RFC9502] [RFC9351] aiming to represent low
   latency topologies being based on the time reference measured among

Contreras & Bazan          Expires 6 May 2027                   [Page 2]
Internet-Draft        Time measurement calibration         November 2026

   devices.  Furthermore, services sensitive to latency, such as the
   deterministic ones [RFC8557] or those following the network slicing
   paradigm [RFC9543], require from accurate information in order to
   place flows in the network.

   The measurements here considered are those performed between neighbor
   nodes in a network, so that an end-to-end delay metric can be
   composed by aggregating partial measurements.  To ensure consistency
   and accuracy across different network element implementations, a
   benchmarking procedure is necessary to calibrate the timestamps.
   This allows correction of observed measurements and improves the
   reliability of latency-based traffic engineering decisions.

   Different protocols are implemented nowadays on network devices to
   perform such measurements, such as TWAMP-light [RFC5357] [RFC8545] or
   STAMP [RFC8972].  It is then important to ensure that the time stamp
   produced by the network device is accurate so that the traffic
   engineering decisions based on such measurements are correct.
   Differences in timestamp generation architecture may introduce
   systematic offsets and bias that affect measurement accuracy.
   Differences on accuracy of the measurements among devices can be due
   to different causes, such as different solutions for time stamping
   (e.g., hardware-based vs software-based), different module involved
   in the time stamping process (e.g., central processor vs line card),
   different type of component taking care of the timestamping (e.g.,
   Network Processor, ASIC, hardware accelerator, etc), etc.

   The traffic engineering decisions will be typically implemented by
   centralized controllers, which can process the measurements and
   decide on the specific traffic engineering path.  This can be the
   case of the Path Computing Element (PCE) [RFC5440].  It is important
   to note that any deviations or bias on the time stamps of the packets
   can lead to inaccurate calculations or decisions.

   An example is the following: Network Device A can introduce some
   delay (e.g., due to less powerful processing capabilities) in the
   timestamp versus Network Device B.  In a dual-plane backbone, with
   similar characteristics in terms of physical path length, where one
   of the planes is built with network devices of type A while the other
   one is built with network devices of type B, the difference between
   the time stamps in A and B can lead to all the traffic being
   delivered by one of the planes.  This is the case, for instance, in a
   dual-connect architecture enabling MPLS and SRv6 coexistence with
   Flex-Algo, operating over protected IP Backbone paths with identical
   physical path lengths.  In this scenario hardware heterogeneity can
   introduce measurement asymmetries.  Discrepancies in the timestamp
   processing capabilities implemented in the two types of network
   devices may occur.  If a low-latency Flex-Algo topology is deployed

Contreras & Bazan          Expires 6 May 2027                   [Page 3]
Internet-Draft        Time measurement calibration         November 2026

   and used for traffic engineering, this measurement offset can
   artificially skew the metric calculation, causing the path
   computation to steer the traffic exclusively over certain paths,
   thereby impacting the expected policy load distribution or path
   protection.

   The purpose of this document is to present a benchmarking procedure
   to calibrate the time stamps of different network device
   implementations so that the observed measured can be corrected if
   needed during the processing of the measured time-stamped data.

2.  Baseline measurement scenario

   In order to create a reference or baseline to later on compare the
   measurements obtained from distinct network elements, a reference
   scenario is defined.  This reference scenario will serve to calibrate
   the time stamps of the different network devices.

   The reference scenario assume an instrumentation device generating
   and receiving TWAMP-light or STAMP packets.  Those packets are
   delivered on a fiber spool of a given known length, L.  Typical
   lengths for testing purposes are in the order of 20 - 100 kms.  It
   can be assumed a delay of 5 us/km on that fiber spool [ITU-T-G.114].
   The measurement setup is as follows:

                               +------------+
                               |            |
                  +------------|  tester    |<-------------+
                  |            |            |              |
                  |            +------------+              |
                  |                                        |
                  |                                        |
                  |        Fiber spool of length L         |
                  +----------------------------------------+

                  Figure 1: Baseline measurement scenario

   The tester will generate the baseline measurement for the time spent
   on delivering packets through the link represented by the fiber
   spool.  Such a reference value can be defined as T_baseline and will
   serve for comparison of the measurements performed by the distinct
   implementations of network elements for calibration purposes.

3.  Network Element Calibration Tests

   As in the baseline scenario described previously, equivalent
   calibration procedures can be performed using actual network
   elements.  The following test scenarios are considered.

Contreras & Bazan          Expires 6 May 2027                   [Page 4]
Internet-Draft        Time measurement calibration         November 2026

   *  Single network element test, performing the test with just one
      single network element, similar to the baseline scenario.  This
      kind of test can be useful for characterizing the behavior of one
      specific network device implementation, including both its
      hardware and software components.

   *  Paired network element test, performing the test between two
      network elements.  This can be useful for determining interworking
      scenarios, considering either network elements from the same
      vendor but with different characteristics (e.g., network device
      model, hardware or software characteristics, etc), or network
      elements from different vendors.

3.1.  Single network element test

   The scenario is similar to the baseline scenario, as follows.

                               +------------+
                               |  Network   |
                  +------------|  Element   |<-------------+
                  |            |     A      |              |
                  |            +------------+              |
                  |                                        |
                  |                                        |
                  |        Fiber spool of length L         |
                  +----------------------------------------+

                   Figure 2: Single network element test

   As before, the network element generates measurement packets through
   the link represented by the fiber spool.  The obtained value can be
   referred as T_ne.

   The calibration exercise results from the comparison between
   T_baseline and T_ne.  Thts is, the difference between T_ne and
   T_baseline provides an indication of the measurement accuracy and
   potential timestamping bias associated with the network element under
   test.

   The characteristics of both ports and line cards used to terminate
   the fiber spool may influence the observed measurements.  Different
   hardware implementations can introduce additional latency or
   timestamping variations.  Therefore, calibration tests should
   document the specific interface and line card used during the
   measurement process.

Contreras & Bazan          Expires 6 May 2027                   [Page 5]
Internet-Draft        Time measurement calibration         November 2026

3.2.  Paired network elements test

   This scenario considers the measurement to be performed between a
   pair of network elements, as follows.

               +------------+                         +------------+
               |  Network   | Fiber spool of length L |  Network   |
               |  Element   |<----------------------->|  Element   |
               |     A      |                         |     B      |
               +------------+                         +------------+

                   Figure 3: Paired network elements test

   The network elements may belong to the same or different vendor.  The
   purpose of this test is to calibrate in interoperability scenarios
   where the the devices involved represent different implementations of
   the same network device functionality, including the protocols used
   for time stamping.

   In this case, one of the network elements generates measurement
   packets over the link represented by the fiber spool of known length
   (and previously measured in the reference scenario).  The value
   obtained from the measurement packets from Network Element A to
   Network Element B can be referred as T_ne_ab.  Similarly, it is
   possible to obtain T_ne_ba on the other direction.

   The calibration procedure consists of comparing the measured values
   against the baseline reference value T_baseline.

   Assuming that both T_ne_ab and T_ne_ba produce the same result, the
   calibration exercise results from the comparison between T_baseline
   and T_ne_ab (or T_ne_ba).  Whatever observed deviation will provide
   an indication of the combined effect of the measurement accuracy and
   timestamping characteristics of the network elements participating in
   the test.

   On the other hand, differences observed between T_ne_ab and T_ne_ba
   may indicate asymmetric forwarding behavior, differences in timestamp
   generation mechanisms, synchronization inaccuracies, or
   implementation-specific characteristics affecting the measurement
   process.

3.3.  Measurement conditions

   The measurements defined in this document should specify the
   following information:

Contreras & Bazan          Expires 6 May 2027                   [Page 6]
Internet-Draft        Time measurement calibration         November 2026

   *  Network device model, including a description of the hardware and
      software version used during the test.

   *  Length of the fiber spool used as calibration reference for the
      measurement.

   *  Description of the ports and line card where the fiber spool is
      connected, since different line cards could produce measurements
      with different accuracy levels.

   *  Protocol used in the measurement (e.g., TWAMP-light, STAMP, ...).

   *  Clock source (e.g., GNSS, PTP, SyncE, NTP, holdover, etc).

   *  Duration of the test for statistical consistency (e.g., period for
      average, min, max calculations)

   *  Network tester or instrumentation used for generating the baseline
      values.

   In addition, if available, the exact timestamp insertion point is of
   interest since this information is relevant for interpreting
   differences observed implementations and hardware architectures.  For
   instance, insertion points such as Network Processing Unit (NPU),
   forwarding ASIC, line card CPU, route processor, etc.

   (Note: to consider scalability aspects on the collected measurements
   that could impact the calibration exercise.  For instance, if
   multiple sessions are running in parallel from one node to several
   neighbor nodes, with one session per neighbor).

3.4.  Resolution of the calibration process

   The calibration process of the time-stamps observed during the
   benchmarking methodology needs to take into account the time units of
   relevance for the purpose of the usage of such measurements.

   The timestamp format used in TWAMP, TWAMP Light, and STAMP protocols
   is based on the NTP format, as defined in [RFC8877].  These protocols
   employ a 64-bit timestamp, where:

   *  The first 32 bits represent the number of seconds since the NTP
      epoch (January 1, 1900)

   *  The remaining 32 bits represent fractional seconds.

   This structure provides a theoretical resolution of approximately 233
   picoseconds.

Contreras & Bazan          Expires 6 May 2027                   [Page 7]
Internet-Draft        Time measurement calibration         November 2026

   For instance, with this in mind, if the purpose is the generation of
   FlexAlgo topologies based on delay, it should be taken into account
   that the delay field advertised when using IS-IS [RFC8570] or OSPF
   [RFC7471] is expressed in microseconds.  Thus, differences below a
   microsecond are not relevant.  OSPF or IS-IS with traffic engineering
   extensions encode the "delay" value in microseconds using 24-bit
   fields.  This naturally results in lower precision compared to the
   timestamp format used in active measurement protocols.

   When calibrating measurements for use in network operations or
   control plane mechanisms, it is crucial to consider the specific use
   case of the timestamp to ensure appropriate granularity and accuracy.
   For example, in the case of constructing low-latency FlexAlgo
   topologies, it is necessary to align the measurement resolution to
   microseconds, as this is the resolution that the IGP protocol can
   propagate towards the control plane generating the low-latency
   topology.  To achieve this, the measured delay collected by means of
   TWAMP, TWAMP Light, and STAMP protocols SHOULD be adjusted using a
   ceiling function, i.e., rounding up to the nearest integer value in
   microseconds.

   Other use cases, however, may require different resolution levels,
   rounding techniques, or adjustments depending on operational goals.

3.5.  Repeatability and Stability Assessment

   Repeatability is relevant in order to provide a more complete
   characterization of the calibration process.  Accuracy obtained from
   a single execution does not guarantee the temporal consistency of the
   measurementa.  The calibration process MUST include repeatability
   tests intended to evaluate the stability of the measurement results
   over time.  This is related to the number of independent measurement
   runs and the number of samples per measurement run.

3.6.  Calibration Under Operational Load Conditions

   Results obtained under idle or low-load conditions may not accurately
   represent the behavior of a network element operating in production
   environments.  Factors such as increased CPU utilization, buffer
   occupancy, forwarding pipeline congestion, and telemetry processing
   overhead can affect timestamp generation and measurement accuracy.

   Therefore, the calibration process SHOULD be repeated under different
   levels of operational load in order to evaluate the stability and
   accuracy of the measurement system under realistic operating
   conditions.

   The following load levels are RECOMMENDED:

Contreras & Bazan          Expires 6 May 2027                   [Page 8]
Internet-Draft        Time measurement calibration         November 2026

           +------------+----------------------+
           | Condition  | Resource Utilization |
           +------------+----------------------+
           | Idle       | 0%                   |
           | Low        | 25%                  |
           | Medium     | 50%                  |
           | High       | 75%                  |
           | Saturation | 95%                  |
           +------------+----------------------+

   The characteristics of the background traffic used to generate the
   load on the link SHOULD be documented as part of the calibration
   report.

4.  Further discussions

   This is a placeholder for capturing topics that will be considered
   for next versions of the document.

4.1.  Consideration of hybrid methods (e.g., IOAM) as measurement
      mechanisms for calibration assessment

   On-path hybrid methods, such as In situ Operations, Administration,
   and Maintenance (IOAM) [RFC9197] [RFC9326] allow the obtention of
   telemetry information that can be used for measuring delays in
   network links.  The IOAM data can be embedded in different
   encapsulations.

   While these methods coud be used for collecting the metric of
   interest, in the context of calibrating hop-by-hop measurements, it
   would impose practical limitations.  For instance, the need of
   generating individual flows per hop for the solely purpose of
   measuring the link delay.  Furthermore, it would require the
   specification of the measurement conditions in terms of the flows
   used for embedding the telemetry data.

4.2.  Usage of instrumentation instead of physical fiber spools for
      determining the baseline value

   Instrumentation equipment can introduce impairments in a link in a
   controlled manner, either as a deterministic or statistical manner.
   For the purpose of the calibration pursued in this document, the
   usage of instrumentation equipment can be considered instead of
   physical fiber spools by configuring deterministic delay values.

   While this can be a proper approach, it presents some practical
   shortcomings.  For instance, the need of supporting all the variety
   of interface bit rates of interest in the platforms to be calibrated.

Contreras & Bazan          Expires 6 May 2027                   [Page 9]
Internet-Draft        Time measurement calibration         November 2026

4.3.  Cross-Method Validation

   Multiple measurement solutions may coexist within the same
   operational environment.  Differences in measurement collection,
   processing methodologies, timestamp generation mechanisms per
   solution, and data aggregation techniques may result in systematic
   deviations between different measurement methods.

   The objective of this analysis is to determine the level of
   convergence between different measurement methodologies and to
   identify potential systematic deviations among implementations of the
   different measurement solutions.

5.  References

5.1.  Normative References

   [RFC5357]  Hedayat, K., Krzanowski, R., Morton, A., Yum, K., and J.
              Babiarz, "A Two-Way Active Measurement Protocol (TWAMP)",
              RFC 5357, DOI 10.17487/RFC5357, October 2008,
              <https://www.rfc-editor.org/info/rfc5357>.

   [RFC5440]  Vasseur, JP., Ed. and JL. Le Roux, Ed., "Path Computation
              Element (PCE) Communication Protocol (PCEP)", RFC 5440,
              DOI 10.17487/RFC5440, March 2009,
              <https://www.rfc-editor.org/info/rfc5440>.

   [RFC7471]  Giacalone, S., Ward, D., Drake, J., Atlas, A., and S.
              Previdi, "OSPF Traffic Engineering (TE) Metric
              Extensions", RFC 7471, DOI 10.17487/RFC7471, March 2015,
              <https://www.rfc-editor.org/info/rfc7471>.

   [RFC8545]  Morton, A., Ed. and G. Mirsky, Ed., "Well-Known Port
              Assignments for the One-Way Active Measurement Protocol
              (OWAMP) and the Two-Way Active Measurement Protocol
              (TWAMP)", RFC 8545, DOI 10.17487/RFC8545, March 2019,
              <https://www.rfc-editor.org/info/rfc8545>.

   [RFC8570]  Ginsberg, L., Ed., Previdi, S., Ed., Giacalone, S., Ward,
              D., Drake, J., and Q. Wu, "IS-IS Traffic Engineering (TE)
              Metric Extensions", RFC 8570, DOI 10.17487/RFC8570, March
              2019, <https://www.rfc-editor.org/info/rfc8570>.

   [RFC8972]  Mirsky, G., Min, X., Nydell, H., Foote, R., Masputra, A.,
              and E. Ruffini, "Simple Two-Way Active Measurement
              Protocol Optional Extensions", RFC 8972,
              DOI 10.17487/RFC8972, January 2021,
              <https://www.rfc-editor.org/info/rfc8972>.

Contreras & Bazan          Expires 6 May 2027                  [Page 10]
Internet-Draft        Time measurement calibration         November 2026

   [RFC9197]  Brockners, F., Ed., Bhandari, S., Ed., and T. Mizrahi,
              Ed., "Data Fields for In Situ Operations, Administration,
              and Maintenance (IOAM)", RFC 9197, DOI 10.17487/RFC9197,
              May 2022, <https://www.rfc-editor.org/info/rfc9197>.

   [RFC9326]  Song, H., Gafni, B., Brockners, F., Bhandari, S., and T.
              Mizrahi, "In Situ Operations, Administration, and
              Maintenance (IOAM) Direct Exporting", RFC 9326,
              DOI 10.17487/RFC9326, November 2022,
              <https://www.rfc-editor.org/info/rfc9326>.

   [RFC9351]  Talaulikar, K., Ed., Psenak, P., Zandi, S., and G. Dawra,
              "Border Gateway Protocol - Link State (BGP-LS) Extensions
              for Flexible Algorithm Advertisement", RFC 9351,
              DOI 10.17487/RFC9351, February 2023,
              <https://www.rfc-editor.org/info/rfc9351>.

   [RFC9502]  Britto, W., Hegde, S., Kaneriya, P., Shetty, R., Bonica,
              R., and P. Psenak, "IGP Flexible Algorithm in IP
              Networks", RFC 9502, DOI 10.17487/RFC9502, November 2023,
              <https://www.rfc-editor.org/info/rfc9502>.

   [RFC9534]  Li, Z., Zhou, T., Guo, J., Mirsky, G., and R. Gandhi,
              "Simple Two-Way Active Measurement Protocol Extensions for
              Performance Measurement on a Link Aggregation Group",
              RFC 9534, DOI 10.17487/RFC9534, January 2024,
              <https://www.rfc-editor.org/info/rfc9534>.

5.2.  Informative References

   [ITU-T-G.114]
              "One-way transmission time", May 2003.

   [RFC8557]  Finn, N. and P. Thubert, "Deterministic Networking Problem
              Statement", RFC 8557, DOI 10.17487/RFC8557, May 2019,
              <https://www.rfc-editor.org/info/rfc8557>.

   [RFC8877]  Mizrahi, T., Fabini, J., and A. Morton, "Guidelines for
              Defining Packet Timestamps", RFC 8877,
              DOI 10.17487/RFC8877, September 2020,
              <https://www.rfc-editor.org/info/rfc8877>.

   [RFC9543]  Farrel, A., Ed., Drake, J., Ed., Rokui, R., Homma, S.,
              Makhijani, K., Contreras, L., and J. Tantsura, "A
              Framework for Network Slices in Networks Built from IETF
              Technologies", RFC 9543, DOI 10.17487/RFC9543, March 2024,
              <https://www.rfc-editor.org/info/rfc9543>.

Contreras & Bazan          Expires 6 May 2027                  [Page 11]
Internet-Draft        Time measurement calibration         November 2026

Appendix A.  Measurement data normalization

   As part of the comparison of the measurements produced by different
   implementations, a data normalization process could be required.  The
   goal is to ensure that functionally equivalent metrics can be
   compared consistently in multivendor scenarios.  The reason for it is
   that network elements from different vendors can use distinct metric
   names, units of measurement, temporal granularities, timestamp
   formats, and statistical methodologies to represent equivalent
   performance indicators.

   Such normalization process can imply the mapping of equivalent
   metrics, the conversion of reported units, the temporal granularity
   considered, the aligment of the statistical window used and the
   normalization of the timestamp format.

   The objective of metric normalization is to ensure that equivalent
   measurements collected from heterogeneous implementations are
   interpreted and processed in a consistent manner.

   An example of metric normalization is shown below:

           +----------+------------------+----------------+
           | Vendor   | Native Metric    | Normalized KPI |
           +----------+------------------+----------------+
           | Nokia    | round-trip-delay | RTT            |
           | Cisco    | network-delay    | RTT            |
           | HPE      | rtt-average      | RTT            |
           | Huawei   | delay-average    | RTT            |
           +----------+------------------+----------------+

   Once calibrated, normalized measurement data may be subsequently
   exported to observability platforms, analytics systems, Software-
   Defined Networking (SDN) controllers, automation frameworks, and data
   lake environments.

   This procedure can lead to accurate comparisons, consistent
   performance assessments, and correct Traffic Engineering decisions in
   multivendor operational environments.

Contreras & Bazan          Expires 6 May 2027                  [Page 12]
Internet-Draft        Time measurement calibration         November 2026

Appendix B.  Calibration Considerations for Link Aggregation Groups
             (LAGs)

   Link Aggregation Groups (LAGs) are widely deployed in operational
   networks to increase available bandwidth and provide resiliency
   through the use of multiple physical links presented as a single
   logical interface.    Although LAG member links are treated by the
   control plane as a single logical resource, individual member links
   may exhibit different performance characteristics, including
   variations in delay, packet loss, delay variation, and utilization.
   Performance differences among member links of the same LAG may occur
   due to different reasons, like different physical link lengths,
   intermittent failures affecting individual member links, etc.    As
   consequence of that, measurements performed exclusively on the
   aggregated LAG may hide degradations affecting individual member
   links.    [RFC9534] defines extensions to the Simple Two-Way Active
   Measurement Protocol (STAMP) that enable performance measurements on
   individual LAG member links through the use of micro sessions.  These
   extensions allow measurement sessions to be associated with specific
   physical member links, enabling independent assessment of the
   performance of each member within the aggregation group.

   When the network element under test utilizes LAGs, the calibration
   process SHOULD evaluate each member link individually.  The purpose
   of this is to identify performance differences among individual
   member links that may not be observable when measurements are
   performed exclusively on the aggregated logical interface.

   Measurement results SHOULD be reported individually for each member
   link prior to the calculation or presentation of aggregated LAG
   statistics.  The calibration report SHOULD identify the member link
   associated with each measurement and document any observed
   differences among members.

Acknowledgements

   The author would like to thank Miguel Cros (Telefonica) for the
   discusions on the topic.  Moreover the author would like also thank
   Giuseppe Fioccola, Tal Mizrahi, Carsten Rossenhoevel for the valuable
   comments received during the BMWG meetings.

   This work has been partially funded by the European Commission
   through the Horizon Europe SNS JU PREDICT-6G project (GA 101095890).

Authors' Addresses

Contreras & Bazan          Expires 6 May 2027                  [Page 13]
Internet-Draft        Time measurement calibration         November 2026

   Luis M. Contreras
   Telefonica
   Ronda de la Comunicacion, s/n
   28050 Madrid
   Spain
   Email: luismiguel.contrerasmurillo@telefonica.com

   Adilson Bazan
   Telefonica
   Sao Paulo-
   Brazil
   Email: adilson.fernandes@telefonica.com