QUIC Usage Guidance in the Internet of Things (IoT)
draft-gomez-iotops-quic-iot-00
This document is an Internet-Draft (I-D).
Anyone may submit an I-D to the IETF.
This I-D is not endorsed by the IETF and has no formal standing in the
IETF standards process.
| Document | Type | Active Internet-Draft (individual) | |
|---|---|---|---|
| Authors | Carles Gomez , Nika Soltani-Tehrani , Jon Crowcroft | ||
| Last updated | 2026-08-14 | ||
| RFC stream | (None) | ||
| Intended RFC status | (None) | ||
| Formats | |||
| Stream | Stream state | (No stream defined) | |
| Consensus boilerplate | Unknown | ||
| RFC Editor Note | (None) | ||
| IESG | IESG state | I-D Exists | |
| Telechat date | (None) | ||
| Responsible AD | (None) | ||
| Send notices to | (None) |
draft-gomez-iotops-quic-iot-00
IOTOPS Working Group C. Gomez
Internet-Draft N. Soltani-Tehrani
Intended status: Informational UPC
Expires: 15 February 2027 J. Crowcroft
University of Cambridge
August 2026
QUIC Usage Guidance in the Internet of Things (IoT)
draft-gomez-iotops-quic-iot-00
Abstract
This document provides guidance on how to use QUIC in Constrained-
Node Networks (CNNs), which are a characteristic of the Internet of
Things (IoT).
Status of This Memo
This Internet-Draft is submitted in full conformance with the
provisions of BCP 78 and BCP 79.
Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF). Note that other groups may also distribute
working documents as Internet-Drafts. The list of current Internet-
Drafts is at https://datatracker.ietf.org/drafts/current/.
Internet-Drafts are draft documents valid for a maximum of six months
and may be updated, replaced, or obsoleted by other documents at any
time. It is inappropriate to use Internet-Drafts as reference
material or to cite them other than as "work in progress."
This Internet-Draft will expire on 2 February 2027.
Copyright Notice
Copyright (c) 2026 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents (https://trustee.ietf.org/
license-info) in effect on the date of publication of this document.
Please review these documents carefully, as they describe your rights
and restrictions with respect to this document. Code Components
extracted from this document must include Revised BSD License text as
described in Section 4.e of the Trust Legal Provisions and are
provided without warranty as described in the Revised BSD License.
Gomez, et al. Expires 15 February 2027 [Page 1]
Internet-Draft QUIC in IoT August 2026
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . 2
2. Terminology . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.1. Requirements language . . . . . . . . . . . . . . . . . . 3
3. Constrained-Node Network characteristics . . . . . . . . . . 3
4. QUIC guidance for CNNs . . . . . . . . . . . . . . . . . . . 3
4.1. Connections . . . . . . . . . . . . . . . . . . . . . . . 4
4.1.1. Client and server role . . . . . . . . . . . . . . . 4
4.1.2. Connection duration . . . . . . . . . . . . . . . . . 4
4.2. Initial and minimum congestion window . . . . . . . . . . 4
4.3. Reliable versus unreliable datagrams . . . . . . . . . . 5
4.4. Header overhead . . . . . . . . . . . . . . . . . . . . . 5
4.5. ACK frequency . . . . . . . . . . . . . . . . . . . . . . 6
4.6. Initial RTT and related parameters . . . . . . . . . . . 6
5. Security Considerations . . . . . . . . . . . . . . . . . . . 7
6. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 7
7. References . . . . . . . . . . . . . . . . . . . . . . . . . 7
7.1. Normative References . . . . . . . . . . . . . . . . . . 7
7.2. Informative References . . . . . . . . . . . . . . . . . 8
Acknowledgments . . . . . . . . . . . . . . . . . . . . . . . . . 8
Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . . 9
1. Introduction
QUIC is a modern transport-layer protocol intended to provide end-to-
end reliability and security [RFC9000][RFC9001][RFC9002]. It was
designed to overcome several issues of prior protocol stacks, such as
Transmission Control Protocol (TCP)/Transport Layer Security (TLS)
[RFC9293][RFC9846].
QUIC was not specifically designed for Constrained-Node Networks
(CNNs), which are typical in Internet of Things (IoT) environments
[I-D.ietf-iotops-7228bis]. However, its increasing adoption on the
Internet suggests that QUIC may become a protocol to consider also
for CNNs. Reasons include compatibility with existing QUIC-based
infrastructure, availability of a wide panoply of implementations and
tools, and a significant community, among others.
Leveraging optional and configurable functionality in QUIC, this
document aims to provide guidance on how QUIC can be tailored for
improved operation over CNNs.
2. Terminology
Gomez, et al. Expires 15 February 2027 [Page 2]
Internet-Draft QUIC in IoT August 2026
2.1. Requirements language
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
"OPTIONAL" in this document are to be interpreted as described in
BCP14 [RFC2119], [RFC8174], when, and only when, they appear in all
capitals, as shown here.
The reader is assumed to be familiar with the terms and concepts
defined in [RFC9000][RFC9001][RFC9002][I-D.ietf-iotops-7228bis].
3. Constrained-Node Network characteristics
CNNs are defined in [I-D.ietf-iotops-7228bis] as networks "whose
characteristics are influenced by being composed of a significant
portion of constrained nodes". The latter exhibit significant
limitations on processing, memory, and energy resources
[I-D.ietf-iotops-7228bis]. The first two dimensions pose constraints
on the complexity and memory footprint of the protocols that
constrained nodes can support. Energy availability constraints
requires using techniques to save energy, such as radio duty-cycling
in wireless devices [RFC8352], and the minimization of the number of
messages transmitted/received, as well as their size.
[I-D.ietf-iotops-7228bis] lists typical network constraints in CNNs,
including low achievable bitrate/throughput, high packet loss and
high variability of packet loss, highly asymmetric link
characteristics, severe penalties for using larger packets, limits on
reachability over time, high latency (e.g., due to sleep intervals
intended to save energy), etc. CNNs may use wireless or wired
technologies (e.g., Power Line Communication), and the transmission
rates are in many cases low (e.g., below 1 Mbit/s), even challenging
responsiveness in scenarios where a human expects an action to occur
after the transmission of a frame.
Many constrained nodes communicate end to end with capable nodes
[I-D.ietf-iotops-7228bis] (e.g., located in the cloud or at the
edge). However, end-to-end communication between constrained nodes
is also possible.
4. QUIC guidance for CNNs
This section provides guidance on how to use or configure QUIC for
CNNs. Advice is provided in the following areas: connections,
initial and minimum congestion window, reliable versus unreliable
datagrams, header overhead, ACK frequency, and initial RTT and
related parameters.
Gomez, et al. Expires 15 February 2027 [Page 3]
Internet-Draft QUIC in IoT August 2026
4.1. Connections
4.1.1. Client and server role
In QUIC, connection establishment is initiated by a client. In order
to better accommodate possible energy-saving techniques (e.g., radio
duty-cycling) of a constrained device, the latter is recommended to
act as client in a QUIC connection. This approach makes it easier
for the constrained device to initiate connection establishment when
it is ready to do so.
4.1.2. Connection duration
In order to minimize protocol overhead, a connection between a client
and a server should last for as long as possible. In fact, many CNN
use cases involve sensors that periodically send measurement reports
over years of battery lifetime. It is possible to disable the idle
timeout (max_idle_timeout) when both endpoints omit this parameter or
indicate a value of 0.
However, most practical environments involve middleboxes (e.g.,
firewalls) that may block a UDP flow after 30 seconds of inactivity
[RFC9000]. In such cases, two approaches can be followed at the QUIC
level to avoid connectivity issues between the client and the server:
i) sending a packet containing a PING frame from the client before 30
seconds have passed since the last transmitted or received QUIC
packet, and ii) opening a new connection between the same client and
server when the client has new data to send and more than 30 seconds
have passed since the last transmitted or received QUIC packet.
Another approach is using application-layer heartbeat messages.
Periodic application-layer heartbeats can prevent early record
deletion in middleboxes. If the UDP binding timeout for a middlebox
to be traversed by a given connection is known, middlebox filter
state deletion will be avoided if the heartbeat period is lower than
the middlebox UDP binding timeout. One specific advantage of
heartbeat messages is that they also allow liveness checks at the
application level.
4.2. Initial and minimum congestion window
In QUIC, the recommended value for the initial congestion window is
"ten times the maximum datagram size (max_datagram_size), while
limiting the window to the larger of 14,720 bytes or twice the
maximum datagram size". On the other hand, the recommended value for
the minimum congestion window is equal to 2 * max_datagram_size.
Some constrained devices may only be able to support smaller window
sizes. For such devices, the initial and minimum congestion window
Gomez, et al. Expires 15 February 2027 [Page 4]
Internet-Draft QUIC in IoT August 2026
need to be set accordingly, even if they result in smaller values
than the default ones recommended.
4.3. Reliable versus unreliable datagrams
In IoT scenarios, reliability requirements vary depending on the
considered application. Some data packets require reliable delivery,
whereas others do not. QUIC provides reliable data delivery by
default, using Acknowledgments (ACKs) and retransmission of lost
data. However, in order to reduce protocol overhead, it is possible
to carry less critical data atop DATAGRAM frames [RFC9221]. Such
frames elicit ACKs, but are not retransmitted upon loss detection.
4.4. Header overhead
Some of the fields in QUIC packet and frame formats, such as
Connection ID and packet number fields, are of variable size. In
some circumstances, it is possible to exploit this feature to reduce
packet header overhead, considering the associated trade-offs.
Connection ID fields have a size between 0 and 20 bytes. Reducing
the size of a Connection ID degrades communication privacy and may
decrease the efficiency of load balancing operations. If these
concerns do not apply or can be tolerated to some extent for a
particular IoT scenario, the latter may benefit from using shorter-
sized Connection ID fields. As described in RFC 9000, "a zero-length
connection ID can be used when a connection ID is not needed to route
to the correct endpoint". However, a zero-sized Connection ID may
only be safely used in very controlled environments.
Packet numbers have a size between 1 and 4 bytes. Reducing the
packet number size increases the probability of ambiguity in
identifying packets. However, if the rate of packets to be sent over
a connection is expected to be low (e.g., a sensor that transmits a
reading every minute) or ACKs are received at a sufficient rate, a
shorter packet number size can be safely used.
Many IoT use cases (e.g., a device periodically sending sensor
readings) do not require more than a single stream per connection.
This provides an intrinsic limitation to packet header overhead.
Another approach to reduce packet overhead in QUIC is using header
compression. For example, Static Context Header Compression (SCHC)
[RFC8724] has been proposed for QUIC
[I-D.sirohi-schc-quic-compression].
Gomez, et al. Expires 15 February 2027 [Page 5]
Internet-Draft QUIC in IoT August 2026
4.5. ACK frequency
A typical IoT use case is a sensor that periodically transmits a
single data packet containing a sensor reading. Even if the minimum
recommended congestion window is 2 packets, the sender in such use
case will typically only keep one packet in flight at most. In such
case, if an application-layer response is not elicited, the receiver
will delay sending the corresponding ACK by max_ack_delay, which has
the default value of 25 ms. This mechanism is an attempt to reduce
the number of ACKs or packets transmitted by the receiver, but in
this specific case, the ACK will just be unnecessarily delayed,
potentially consuming more energy on the sensor, without decreasing
the actual number of ACKs sent.
One way to request an ACK to be sent immediately is by including an
IMMEDIATE_ACK frame in the packet carrying the STREAM frame with the
user data, which increases the packet size by one byte. In this
case, immediate ACK transmission applies only to the next ACK to be
sent. It is also possible to request ACKs to be sent immediately by
sending a packet containing an ACK_FREQUENCY frame with the Requested
Max Ack Delay field set to zero microseconds. This is a request that
should produce a steady-state ACK transmission behavior (of ACKs
being sent immediately). Note that, in this case, the minimum value
for min_ack_delay supported by the receiver needs to be zero.
For less constrained IoT devices, in scenarios allowing a large
congestion window size, it may be useful to request a lower ACK rate
than default in order to reduce the number of ACKs transmitted by the
receiver. This can be done by sending an ACK_FREQUENCY frame with an
appropriate value for Ack-Eliciting Threshold.
4.6. Initial RTT and related parameters
QUIC defines an initial value for the RTT estimate. According to RFC
9002, "when no previous RTT is available, the initial RTT should be
set to 333 milliseconds". This value, denoted as kInitialRtt, serves
as the starting point for the RTT estimator. One consequence is that
the initial value of the Probe TimeOut (PTO) is 1 second. In turn,
this value affects other parameters, as max_idle_timeout needs to be
at least 3 times the PTO, and the persistent congestion duration is
recommended to be 3 times the PTO.
However, in many IoT scenarios, the RTT is much greater than 1
second. This may be due to various reasons, which could be combined
in some cases: i) bit rates may be low, sometimes below 1 kbit/s; ii)
links may be duty-cycled, leading to long intervals (from seconds to
days) where a constrained device may be in sleep state (i.e., radio
off); iii) some constrained devices use connectivity provided by
Gomez, et al. Expires 15 February 2027 [Page 6]
Internet-Draft QUIC in IoT August 2026
sparse satellite constellations supporting store and forward
operation, introducing delays up to the order of hours; iv) some
technologies (e.g., some Low Power Wide Area Network (LPWAN)
technologies) require uplink transmission from a constrained device
to enable downlink transmission.
RFC 9002 allows a kInitialRtt setting different from 333 ms.
Therefore, in IoT scenarios, such parameter needs to be configured
based on the expected RTT of the intended scenario, often requiring a
greater value than the default one.
5. Security Considerations
TO-DO
6. IANA Considerations
This document has no IANA considerations.
7. References
7.1. Normative References
[I-D.ietf-iotops-7228bis]
Bormann, C., Ersue, M., Keränen, A., and C. Gomez,
"Terminology for Constrained-Node Networks", Work in
Progress, Internet-Draft, draft-ietf-iotops-7228bis-10, 6
July 2026, <https://datatracker.ietf.org/doc/html/draft-
ietf-iotops-7228bis-10>.
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119,
DOI 10.17487/RFC2119, March 1997,
<https://www.rfc-editor.org/info/rfc2119>.
[RFC8174] Leiba, B., "Ambiguity of Uppercase vs Lowercase in RFC
2119 Key Words", BCP 14, RFC 8174, DOI 10.17487/RFC8174,
May 2017, <https://www.rfc-editor.org/info/rfc8174>.
[RFC9000] Iyengar, J., Ed. and M. Thomson, Ed., "QUIC: A UDP-Based
Multiplexed and Secure Transport", RFC 9000,
DOI 10.17487/RFC9000, May 2021,
<https://www.rfc-editor.org/info/rfc9000>.
[RFC9001] Thomson, M., Ed. and S. Turner, Ed., "Using TLS to Secure
QUIC", RFC 9001, DOI 10.17487/RFC9001, May 2021,
<https://www.rfc-editor.org/info/rfc9001>.
Gomez, et al. Expires 15 February 2027 [Page 7]
Internet-Draft QUIC in IoT August 2026
[RFC9002] Iyengar, J., Ed. and I. Swett, Ed., "QUIC Loss Detection
and Congestion Control", RFC 9002, DOI 10.17487/RFC9002,
May 2021, <https://www.rfc-editor.org/info/rfc9002>.
[RFC9221] Pauly, T., Kinnear, E., and D. Schinazi, "An Unreliable
Datagram Extension to QUIC", RFC 9221,
DOI 10.17487/RFC9221, March 2022,
<https://www.rfc-editor.org/info/rfc9221>.
7.2. Informative References
[I-D.sirohi-schc-quic-compression]
Sirohi, S. and L. Toutain, "QUIC compression using SCHC",
Work in Progress, Internet-Draft, draft-sirohi-schc-quic-
compression-00, 12 May 2025,
<https://datatracker.ietf.org/doc/html/draft-sirohi-schc-
quic-compression-00>.
[RFC8352] Gomez, C., Kovatsch, M., Tian, H., and Z. Cao, Ed.,
"Energy-Efficient Features of Internet of Things
Protocols", RFC 8352, DOI 10.17487/RFC8352, April 2018,
<https://www.rfc-editor.org/info/rfc8352>.
[RFC8724] Minaburo, A., Toutain, L., Gomez, C., Barthel, D., and JC.
Zuniga, "SCHC: Generic Framework for Static Context Header
Compression and Fragmentation", RFC 8724,
DOI 10.17487/RFC8724, April 2020,
<https://www.rfc-editor.org/info/rfc8724>.
[RFC9293] Eddy, W., Ed., "Transmission Control Protocol (TCP)",
STD 7, RFC 9293, DOI 10.17487/RFC9293, August 2022,
<https://www.rfc-editor.org/info/rfc9293>.
[RFC9846] Rescorla, E., "The Transport Layer Security (TLS) Protocol
Version 1.3", RFC 9846, DOI 10.17487/RFC9846, July 2026,
<https://www.rfc-editor.org/info/rfc9846>.
Acknowledgments
Carles Gomez has been supported in part by the Spanish Goverment's
Ministerio de Ciencia, Innovacion y Universidades
MCIU/AEI/10.13039/501100011033/FEDER/UE through project PID2023-
146378NB-I00, and through the Estancias de Movilidad en Centros
Extranjeros de Ensenanza Superior e Investigacion PRX24/00397 grant.
The authors would like to thank (in alphabetical order) TO-DO for
useful considerations, reviews and comments.
Gomez, et al. Expires 15 February 2027 [Page 8]
Internet-Draft QUIC in IoT August 2026
Authors' Addresses
Carles Gomez
UPC
C/Esteve Terradas, 7
08860 Castelldefels
Spain
Email: carles.gomez@upc.edu
Nika Soltani-Tehrani
UPC
C/Esteve Terradas, 7
08860 Castelldefels
Spain
Email: nika.soltani.tehrani@estudiantat.upc.edu
Jon Crowcroft
University of Cambridge
JJ Thomson Avenue
Cambridge
CB3 0FD
United Kingdom
Email: jon.crowcroft@cl.cam.ac.uk
Gomez, et al. Expires 15 February 2027 [Page 9]