EVPN Virtual Ethernet Segment
draft-ietf-bess-evpn-virtual-eth-segment-19
The information below is for an old version of the document that is already published as an RFC.
| Document | Type |
This is an older version of an Internet-Draft that was ultimately published as RFC 9784.
|
|
|---|---|---|---|
| Authors | Ali Sajassi , Patrice Brissette , Rick Schell , John Drake , Jorge Rabadan | ||
| Last updated | 2025-06-27 (Latest revision 2024-12-09) | ||
| Replaces | draft-sajassi-bess-evpn-virtual-eth-segment | ||
| RFC stream | Internet Engineering Task Force (IETF) | ||
| Intended RFC status | Proposed Standard | ||
| Formats | |||
| Reviews |
INTDIR Telechat review
(of
-13)
by Brian Haberman
Ready w/issues
|
||
| Additional resources | Mailing list discussion | ||
| Stream | WG state | Submitted to IESG for Publication | |
| Document shepherd | Luc André Burdet | ||
| Shepherd write-up | Show Last changed 2024-12-03 | ||
| IESG | IESG state | Became RFC 9784 (Proposed Standard) | |
| Action Holders |
(None)
|
||
| Consensus boilerplate | Yes | ||
| Telechat date | (None) | ||
| Responsible AD | Gunter Van de Velde | ||
| Send notices to | Luc André Burdet <lburdet@cisco.com>, Matthew Bocci <matthew.bocci@nokia.com> | ||
| IANA | IANA review state | IANA OK - No Actions Needed | |
| IANA action state | No IANA Actions |
draft-ietf-bess-evpn-virtual-eth-segment-19
BESS WorkGroup A. Sajassi
Internet-Draft P. Brissette
Intended status: Standards Track Cisco Systems
Expires: 12 June 2025 R. Schell
Verizon
J. Drake
Juniper
J. Rabadan
Nokia
9 December 2024
EVPN Virtual Ethernet Segment
draft-ietf-bess-evpn-virtual-eth-segment-19
Abstract
Ethernet VPN (EVPN) and Provider Backbone EVPN (PBB-EVPN) introduce a
comprehensive suite of solutions for delivering Ethernet services
over MPLS/IP networks. These solutions offer advanced multi-homing
capabilities. Specifically, they support Single-Active and All-
Active redundancy modes for an Ethernet Segment (ES), which is
defined as a collection of physical links connecting a multi-homed
device or network to a set of Provider Edge (PE) devices. This
document extends the concept of an Ethernet Segment by allowing an ES
to be associated with a set of Ethernet Virtual Circuits (EVCs, such
as VLANs) or other entities, including MPLS Label Switched Paths
(LSPs) or Pseudowires (PWs). This extended concept is referred to as
virtual Ethernet Segments (vES). This draft list the requirements
and specifies the necessary extensions to support vES in both EVPN
and PBB-EVPN.
Status of This Memo
This Internet-Draft is submitted in full conformance with the
provisions of BCP 78 and BCP 79.
Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF). Note that other groups may also distribute
working documents as Internet-Drafts. The list of current Internet-
Drafts is at https://datatracker.ietf.org/drafts/current/.
Internet-Drafts are draft documents valid for a maximum of six months
and may be updated, replaced, or obsoleted by other documents at any
time. It is inappropriate to use Internet-Drafts as reference
material or to cite them other than as "work in progress."
This Internet-Draft will expire on 12 June 2025.
Sajassi, et al. Expires 12 June 2025 [Page 1]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
Copyright Notice
Copyright (c) 2024 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents (https://trustee.ietf.org/
license-info) in effect on the date of publication of this document.
Please review these documents carefully, as they describe your rights
and restrictions with respect to this document. Code Components
extracted from this document must include Revised BSD License text as
described in Section 4.e of the Trust Legal Provisions and are
provided without warranty as described in the Revised BSD License.
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1. Requirements Language . . . . . . . . . . . . . . . . . . 3
1.2. vESes in Access Ethernet Networks . . . . . . . . . . . . 3
1.3. vESes in Access MPLS Networks . . . . . . . . . . . . . . 5
2. Terminology . . . . . . . . . . . . . . . . . . . . . . . . . 6
3. Requirements . . . . . . . . . . . . . . . . . . . . . . . . 7
3.1. Single-Homed and Multi-Homed vES . . . . . . . . . . . . 8
3.2. Local Switching . . . . . . . . . . . . . . . . . . . . . 8
3.3. EVC Service Types . . . . . . . . . . . . . . . . . . . . 8
3.4. Designated Forwarder (DF) Election . . . . . . . . . . . 9
3.5. EVC Monitoring . . . . . . . . . . . . . . . . . . . . . 9
3.6. Failure and Recovery . . . . . . . . . . . . . . . . . . 10
3.7. Fast Convergence . . . . . . . . . . . . . . . . . . . . 10
4. Solution Overview . . . . . . . . . . . . . . . . . . . . . . 11
4.1. EVPN DF Election for vES . . . . . . . . . . . . . . . . 11
4.2. Grouping and Route Coloring for vES . . . . . . . . . . . 13
4.2.1. EVPN Route Coloring for vES . . . . . . . . . . . . . 13
4.2.2. PBB-EVPN Route Coloring for vES . . . . . . . . . . . 14
5. Failure Handling and Recovery . . . . . . . . . . . . . . . . 14
5.1. EVC Failure Handling for Single-Active vES in EVPN . . . 16
5.2. EVC Failure Handling for Single-Active vES in PBB-EVPN . 16
5.3. Port Failure Handling for Single-Active vESes in EVPN . . 17
5.4. Port Failure Handling for Single-Active vESes in
PBB-EVPN . . . . . . . . . . . . . . . . . . . . . . . . 18
5.5. Fast Convergence in (PBB-)EVPN . . . . . . . . . . . . . 19
6. Acknowledgements . . . . . . . . . . . . . . . . . . . . . . 21
7. Security Considerations . . . . . . . . . . . . . . . . . . . 21
8. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 21
9. References . . . . . . . . . . . . . . . . . . . . . . . . . 21
9.1. Normative References . . . . . . . . . . . . . . . . . . 21
9.2. Informative References . . . . . . . . . . . . . . . . . 22
Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . . 23
Sajassi, et al. Expires 12 June 2025 [Page 2]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
1. Introduction
Ethernet VPN (EVPN, [RFC7432]) and Provider Backbone EVPN (PBB-EVPN,
[RFC7623])) introduce a comprehensive suite of solutions for
delivering Ethernet services over MPLS/IP networks. These solutions
offer advanced multi-homing capabilities. Specifically, they support
Single-Active and All-Active redundancy modes for an Ethernet Segment
(ES). As defined in [RFC7432], an Ethernet Segment (ES) represents a
collection of Ethernet links that connect a customer site to one or
more PEs devices.
This document extends the concept of an Ethernet Segment by allowing
an ES to be associated with a set of Ethernet Virtual Circuits (EVCs,
such as VLANs) or other entities, including MPLS Label Switched Paths
(LSPs) or Pseudowires (PWs). This extended concept is referred to as
virtual Ethernet Segments (vES). This draft lists the requirements
and specifies the necessary extensions to support vES in both EVPN
and PBB-EVPN. The scope of this document includes PBB-EVPN
[RFC7623], EVPN over MPLS [RFC7432], and EVPN over IP [RFC8365].
However, it excludes EVPN over SRv6 [RFC9252].
1.1. Requirements Language
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
"OPTIONAL" in this document are to be interpreted as described in BCP
14 [RFC2119] [RFC8174] when, and only when, they appear in all
capitals, as shown here.
1.2. vESes in Access Ethernet Networks
Some Service Providers (SPs) seek to extend the concept of physical
Ethernet links in an ES to encompass Ethernet Virtual Circuits
(EVCs), wherein multiple EVCs (such as VLANs) can be aggregated onto
a single physical External Network-to-Network Interface (ENNI). An
ES composed of a set of EVCs rather than physical links is referred
to as a vES. Figure 1 illustrates two PE devices (PE1 and PE2), each
with an ENNI aggregating several EVCs. Some of these EVCs on a given
ENNI can be associated with vESes. For instance, the multi-homed vES
depicted in Figure 1 consists of EVC4 on ENNI1 and EVC5 on ENNI2.
Sajassi, et al. Expires 12 June 2025 [Page 3]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
3rd Party
+-----+ EAP
| CE11|EVC1 +---------+
+-----+ \ | | +---+
Cust. A \-0=========0--ENNI1| |
+-----+ | | ENNI1| | +-------+ +---+
| CE12|EVC2--0=========0--ENNI1|PE1|---| | | |
+-----+ | | ENNI1| | |SP |---|PE3|-
| ==0--ENNI1| | |IP/MPLS| | | \ +---+
+-----+ | / | +---+ |Core | +---+ \-| |
| CE22|EVC3--0==== / | |Network| |CE4|
+-----+ | X | | | +---+ | |
Cust. B | / \ | +---+ | | | | /-| |
+-----+ -0=== ===0--ENNI2| | | |---|PE4|-/ +---+
| CE3 |EVC4/ | | ENNI2|PE2|---| | | |
| |EVC5--0=========0--ENNI2| | +-------+ +---+
+-----+ | | +---+
Cust. C +---------+ /\
/\ ||
|| ENNI
EVCs Interface
<--------802.1Q----------> <---- EVPN Network -----> <-802.1Q->
Figure 1: Dual-homed Device/Network (both SA/AA) and SH on same ENNI
ENNIs are commonly used to reach remote customer sites via
independent Ethernet access networks or third- party Ethernet Access
Providers (EAP). ENNIs can aggregate traffic from many vESes (e.g.,
hundreds to thousands), where each vES is represented by its
associated EVC on that ENNI. As a result, ENNIs and their associated
EVCs are a key element of SP external boundaries that are carefully
designed and closely monitored. As a reminder, the ENNI is the
demarcation between the SP (IP/MPLS Core Network) and the third-party
Ethernet Access Provider.
To meet customers' Service Level Agreements (SLA), SPs build
redundancy via multiple EVPN PEs and across multiple ENNIs (as shown
in Figure 1) where a given vES can be multi-homed to two or more EVPN
PE devices (on two or more ENNIs) via their associated EVCs. Just
like physical ESs in [RFC7432] and [RFC7623] solutions, these vESes
can be single-homed or multi-homed ESs and when multi-homed, then can
operate in either Single-Active or All-Active redundancy modes. In a
typical SP external-boundary scenario (e.g., with an EAP), an ENNI
can be associated with several thousands of single-homed vESes,
several hundreds of Single- Active vESes and it may also be
Sajassi, et al. Expires 12 June 2025 [Page 4]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
associated with tens or hundreds of All-Active vESes. The specific
figures (hundreds, thousands, etc.) used throughout this document
reflect the relative quantities of various elements as understood at
the time of writing.
1.3. vESes in Access MPLS Networks
Other Service Providers (SPs) want to extend the concept of the
physical links in an ES to individual Pseudowires (PWs) or to MPLS
Label Switched Paths (LSPs) in Access MPLS networks - i.e., a vES
consisting of a set of PWs or a set of LSPs. Figure 2 illustrates
this concept.
MPLS Aggregation
Network
+-----+ +-----------------+
| CE11|EVC1 | |
+-----+ \ +AG1-+ PW1 +-+---+
Cust. A -0----|===========| |
+-----+ | ---+===========| | +-------+ +---+
| CE12|EVC2-0/ | PW2 /\ | PE1 +---+ | | |
+-----+ ++---+ /=||=| | | +---+PE3+-
| //=||=| | |IP/MPLS| | | \ +---+
| // \/ +-+---+ |Core | +---+ \-+ |
+-----+EVC3 | PW3// LSP1 | |Network| |CE4|
| CE13| \+AG2-+==// | | | +---+ | |
+-----+ 0 |==/PW4 /\ +-+---+ | | | | /-+ |
0 |==PW5===||=| | | +---+PE4+-/ +---+
+-----+ /++---+==PW6===||=| PE2 +---+ | | |
| CE14|EVC4 | \/ | | +-------+ +---+
+-----+ | LSP2+-+---+
Cust. C +-----------------+
/\
||
EVCs
<--802.1Q--> <-----MPLS Agg----> <--- EVPN Network ---> <-802.1Q->
Figure 2: Dual-Homed and Single-homed Network
on MPLS Aggregation networks
In certain scenarios, Service Providers utilize MPLS Aggregation
Networks that are managed by separate administrative entities or
third-party organizations to gain access to their own IP/MPLS core
network infrastructure. This situation is depicted in Figure 2.
Sajassi, et al. Expires 12 June 2025 [Page 5]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
In such scenarios, a vES is defined as a set of individual PWs when
aggregation is not feasible. If aggregation is possible, the vES can
be associated with a group of PWs that share the same unidirectional
LSP pair, where the LSP pair consists of the ingress and egress LSPs
between the same endpoints.
In the example of Figure 2, EVC3 is connected to a VPWS instance in
AG2 that is connected to PE1 and PE2 via PW3 and PW5 respectively.
EVC4 is connected to another VPWS instance on AG2 that is connected
to PE1 and PE2 via PW4 and PW6, respectively. Since the PWs for the
two VPWS instances can be aggregated into the same LSP pair going to
and coming from the MPLS network, a common vES can be defined for the
four mentioned PWs. In Figure 2, LSP1 and LSP2 represent the two LSP
pairs between PE1 and AG2, and between PE2 and AG2, respectively.
The vES consists of these two LSP pairs (LSP1 and LSP2) and each LSP
pair has two PWs. This vES will be shared by two separate EVPN
instances (e.g., EVI-1 and EVI-2) in the EVPN network. PW3 and PW4
are associated with EVI-1 and EVI-2 respectively on PE1, and PW5 and
PW6 are associated with EVI-1 and EVI-2 respectively on PE2.
In some cases, the aggregation of PWs that share the same LSP pair
may not be possible. For instance, if PW3 were terminated into a
third PE, e.g. PE3, instead of PE1, the vES would need to be defined
on a per individual PW on each PE.
For MPLS/IP access networks where a vES represents a set of LSP pairs
or a set of PWs, this document extends the Single-Active multi-homing
procedures defined in [RFC7432] and [RFC7623] to accommodate vES.
The extension of vES to support All-Active multi-homing in MPLS/IP
access networks is beyond the scope of this document.
This draft defines the concept of a vES and specifies the additional
extensions necessary to support a vES in accordance with [RFC7432]
and [RFC7623]. Section 3 enumerates the set of requirements for a
vES. Section 4 details the extensions for a vES applicable to EVPN
solutions, including those specified in [RFC7432] and [RFC7209].
These extensions are designed to meet the requirements listed in
Section 3. Section 4 also provides an overview of the solution,
while Section 5 addresses failure handling, recovery, scalability,
and fast convergence of [RFC7432] and [RFC7623] for vESes.
2. Terminology
AC: Attachment Circuit
B-MAC: Backbone MAC Address
CE: Customer Edge Device
Sajassi, et al. Expires 12 June 2025 [Page 6]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
C-MAC: Customer/Client MAC Address
DF: Designated Forwarder
ENNI: External Network-Network Interface
ES: Ethernet Segment
ESI: Ethernet Segment Identifier
Ethernet A-D: Ethernet Auto-Discovery Route
EVC: Ethernet Virtual Circuit, [MEF63]
EVI: EVPN Instance
EVPN: Ethernet VPN
I-SID: Service Instance Identifier (24 bits and global within a
PBB network see [RFC7080])
PBB: Provider Backbone Bridge
PBB-EVPN: Provider Backbone Bridge EVPN
PE: Provider Edge Device
VPWS: Virtual Pseudowire Service
Single-Active Redundancy Mode (SA): When only a single PE, among a
group of PEs attached to an Ethernet Segment, is allowed to
forward traffic to/from that Ethernet Segment, then the
Ethernet Segment is defined to be operating in Single-
Active redundancy mode.
All-Active Redundancy Mode (AA): When all PEs attached to an
Ethernet segment, are allowed to forward traffic to/from
that Ethernet Segment, then the Ethernet Segment is defined
to be operating in All-Active redundancy mode.
3. Requirements
This section describes the requirements specific to virtual Ethernet
Segment (vES) for (PBB-)EVPN solutions. These requirements are in
addition to the ones described in [RFC8214], [RFC7432], and
[RFC7623].
Sajassi, et al. Expires 12 June 2025 [Page 7]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
3.1. Single-Homed and Multi-Homed vES
A PE device MUST support the following types of virtual Ethernet
Segments (vES):
(R1a) The PE MUST handle single-homed vESes on a single physical
port, such as a single ENNI.
(R1b) The PE MUST support a combination of single-homed vESes and
Single-Active multi-homed vESes simultaneously on a single physical
port, such as a single ENNI. Throughout this document, Single-Active
multi-homed vESes will be referred to as Single-Active vESes.
(R1c) The PE MAY support All-Active multi-homed vESes on a single
physical port. Throughout this document, All-Active multi-homed
vESes will be referred to as All-Active vESes.
(R1d) The PE MAY support a combination of All-Active vESes along with
other types of vESes on a single physical port.
(R1e) A Multi-Homed vES, whether Single-Active or All-Active, can
span across two or more ENNIs on any two or more PEs.
3.2. Local Switching
Many vESes of different types can be aggregated on a single physical
port on a PE device and some of these vESes can belong to the same
service instance (e.g., EVI). This translates into the need for
supporting local switching among the vESes for the same service
instance on the same physical port (e.g., ENNI) of the PE.
(R3a) A PE device that supports the vES function MUST support local
switching among different vESes associated with the same service
instance on a single physical port. For instance, in Figure 1, PE1
must support local switching between CE11 and CE12, which are mapped
to two single-homed vESes on ENNI1. In the case of Single-Active
vESes, the local switching is performed among active EVCs associated
with the same service instance on the same ENNI.
3.3. EVC Service Types
A physical port, such as an ENNI of a PE device, can aggregate
numerous EVCs, each associated with a vES. An EVC may carry one or
more VLANs. Typically, an EVC carries a single VLAN and is therefore
associated with a single broadcast domain. However, there are no
restrictions preventing an EVC from carrying multiple VLANs.
Sajassi, et al. Expires 12 June 2025 [Page 8]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
(R4a) An EVC can be associated with a single broadcast domain, such
as in a VLAN-based service or a VLAN bundle service.
(R4b) An EVC MAY be associated with several broadcast domains, such
as in a VLAN-aware bundle service.
Similarly, a PE can aggregate multiple LSPs and PWs. In the case of
individual PWs per vES, typically, a PW is associated with a single
broadcast domain, although there are no restrictions preventing a PW
from carrying multiple VLANs if the PW is configured in Raw mode.
(R4c) A PW can be associated with a single broadcast domain, such as
in a VLAN-based service or a VLAN bundle service.
(R4d) An PW MAY be associated with several broadcast domains, such as
in a VLAN-aware bundle service.
3.4. Designated Forwarder (DF) Election
Section 8.5 of [RFC7432] specifies the default procedure for DF
election in EVPN, which is also applied in [RFC7623] and [RFC8214].
[RFC8584] elaborates on additional procedures for DF election in
EVPN. These DF election procedures are performed at the granularity
of (ESI, Ethernet Tag). In the context of a vES, the same EVPN
default procedure for DF election is applicable, but at the
granularity of (vESI, Ethernet Tag). In this context, the Ethernet
Tag is represented by an I-SID in PBB-EVPN and by a VLAN ID (VID) in
EVPN. As described in [RFC7432], this default procedure for DF
election at the granularity of (vESI, Ethernet Tag) is also known as
"service carving." The goal of service carving is to evenly
distribute the DFs for different vESes among various PEs, thereby
ensuring an even distribution of traffic across the PEs. The
following requirements are applicable to the DF election of vESes for
(PBB-)EVPN.
(R5a) A PE that supports vES function, MUST support a vES with m EVCs
among n ENNIs belonging to p PEs in any arbitrary order; where n >= p
>= m >=2. For example, if there is a vES with 2 EVCs and there are 5
ENNIs on 5 PEs (PE1 through PE5), then vES can be dual homed to PE2
and PE4 and the DF election must be performed between PE2 and PE4.
(Rbc) Each vES MUST be identified by its own virtual ESI (vESI).
3.5. EVC Monitoring
To detect the failure of an individual EVC and subsequently perform
DF election for its associated vES as a result of this failure, each
EVC should be monitored independently.
Sajassi, et al. Expires 12 June 2025 [Page 9]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
(R6a) Each EVC SHOULD be independently monitored for its operational
health.
(R6b) A failure in a single EVC, among many aggregated on a single
physical port or ENNI, MUST trigger a DF election for its associated
vES.
3.6. Failure and Recovery
(R7a) Failure and failure recovery of an EVC for a Single-homed vES
SHALL NOT impact any other EVCs within its service instance or any
other service instances. In other words, for PBB-EVPN, it SHALL NOT
trigger any MAC flushing both within its own I-SID as well as other
I-SIDs.
(R7b) In case of All-Active vES, failure and failure recovery of an
EVC for that vES SHALL NOT impact any other EVCs within its service
instance or any other service instances. In other words, for PBB-
EVPN, it SHALL NOT trigger any MAC flushing both within its own I-SID
as well as other I-SIDs.
(R7c) Failure and failure recovery of an EVC for a Single-Active vES
SHALL impact only its own service instance. In other words, for PBB-
EVPN, MAC flushing SHALL be limited to the associated I-SID only and
SHALL NOT impact any other I-SIDs.
(R7d) Failure and failure recovery of an EVC for a Single-Active vES
MUST only impact C-MACs associated with multi-homed device/network
for that service instance. In other words, MAC flushing MUST be
limited to single service instance (I-SID in the case of PBB-EVPN)
and only C-MACs for Single-Active multi-homed device/network.
3.7. Fast Convergence
Since many EVCs (and their associated vESes) are aggregated via a
single physical port (e.g., ENNI), then the failure of that physical
port impacts many vESes and triggers equally many ES route
withdrawals. Formulating, sending, receiving, and processing such
large number of BGP messages can introduce delay in DF election and
convergence time. As such, it is highly desirable to have a
mass-withdraw mechanism similar to the one in [RFC7432] for
withdrawing many Ethernet A-D per ES routes.
(R8a) There SHOULD be a mechanism equivalent to EVPN mass-withdraw
such that upon an ENNI failure, only a single BGP message is needed
to indicate to the remote PEs to trigger DF election for all impacted
vES associated with that ENNI.
Sajassi, et al. Expires 12 June 2025 [Page 10]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
4. Solution Overview
The solutions described in [RFC7432] and [RFC7623] are leveraged
as-is with the modification that the ESI assignment is performed for
an EVC or a group of EVCs or LSPs/PWs instead of a link or a group of
physical links. In other words, the ESI is associated with a virtual
ES (vES), hereby referred to as vESI.
In the EVPN solution, the overall procedures remain consistent, with
the primary difference being the handling of physical port failures
that can affect multiple vESes. Sections 5.1 and 5.3 describe the
procedures for managing physical port or link failures in the context
of EVPN. In a typical multi-homed setup, MAC addresses learned
behind a vES are advertised using the ESI associated with the vES,
referred to as the vESI. EVPN aliasing and mass-withdraw operations
are conducted with respect to the vES identifier. Specifically, the
Ethernet Auto-Discovery (A-D) routes for these operations are
advertised using the vESI instead of the ESI.
For PBB-EVPN solution, the main change is with respect to the B-MAC
address assignment which is performed similar to what is described in
section 7.2.1.1 of [RFC7623] with the following refinements:
* One shared B-MAC address SHOULD be used per PE for the
single-homed vESes. In other words, a single B-MAC is shared for
all single-homed vESes on that PE.
* One shared B-MAC address SHOULD be used per PE per physical port
(e.g., ENNI) for the Single-Active vESes. In other words, a
single B-MAC is shared for all Single-Active vESes that share the
same ENNI.
* One shared B-MAC address MAY be used for all Single-Active vESes
on that PE.
* One B-MAC address SHOULD be used per set of EVCs representing an
All-Active vES. In other words, a single B-MAC address is used
per vES for All-Active scenarios.
* A single B-MAC address MAY also be used per vES per PE for Single-
Active scenarios.
4.1. EVPN DF Election for vES
The procedure for service carving for vESes is almost the same as the
ones outlined in section 8.5 of [RFC7432] and [RFC8584] except for
the fact that ES is replaced with vES.
Sajassi, et al. Expires 12 June 2025 [Page 11]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
For the sake of clarity and completeness, the default DF election
procedure of [RFC7432] is repeated below with the necessary changes:
1. When a PE discovers the vESI or is configured with the vESI
associated with its attached vES, it advertises an Ethernet
Segment route with the associated ES-Import extended community
attribute.
2. The PE then starts a timer (default value = 3 seconds) to allow
the reception of Ethernet Segment routes from other PE nodes
connected to the same vES. This timer value MUST be same across
all PEs connected to the same vES.
3. When the timer expires, each PE builds an ordered list of the IP
addresses of all the PE nodes connected to the vES (including
itself), in increasing numeric value. Each IP address in this
list is extracted from the "Originator Router's IP address" field
of the advertised Ethernet Segment route. Every PE is then given
an ordinal indicating its position in the ordered list, starting
with 0 as the ordinal for the PE with the numerically lowest IP
address. The ordinals are used to determine which PE node will
be the DF for a given EVPN instance on the vES using the
following rule: Assuming a redundancy group of N PE nodes, the PE
with ordinal i is the DF for an EVPN instance with an associated
Ethernet Tag value of V when (V mod N) = i. It should be noted
that using "Originator Router's IP address" field in the Ethernet
Segment route to get the PE IP address needed for the ordered
list, allows for a CE to be multi-homed across different ASes if
such need ever arises.
4. The PE that is elected as a DF for a given EVPN instance will
unblock traffic for that EVPN instance. Note that the DF PE
unblocks all traffic in both ingress and egress directions for
Single-Active vES and unblocks multi-destination in egress
direction for All-Active Multi-homed vES. All non-DF PEs block
all traffic in both ingress and egress directions for Single-
Active vES and block multi-destination traffic in the egress
direction for All-Active vES.
In case of an EVC failure, the affected PE withdraws its
corresponding Ethernet Segment route if there are no more EVCs
associated to the vES in the PE. This will re-trigger the DF
Election procedure on all the PEs in the Redundancy Group. For PE
node failure, or upon PE commissioning or decommissioning, the PEs
re-trigger the DF Election procedure across all affected vESes. In
case of a Single-Active, when a service moves from one PE in the
Redundancy Group to another PE because of DF re-election, the PE,
which ends up being the elected DF for the service, MUST trigger a
Sajassi, et al. Expires 12 June 2025 [Page 12]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
MAC address flush notification towards the associated vES if the
multi-homing device is a bridge or the multi-homing network is an
Ethernet bridged network.
For LSP-based and PW-based vES, the non-DF PE SHOULD signal PW-status
'standby' to the Aggregation PE (e.g., AG1 and AG2 in Figure 2), and
a new DF PE MAY send an LDP MAC withdraw message as a MAC address
flush notification. It should be noted that the PW-status is
signaled for the scenarios where there is a one-to-one mapping
between EVI (EVPN instance) and the PW.
4.2. Grouping and Route Coloring for vES
Physical ports (e.g. ENNI) which aggregate many EVCs are 'colored'
to enable the grouping schemes described below.
By default, the MAC address of the corresponding port (e.g. ENNI) is
used to represent the 'color' of the port, and the EVPN Router's MAC
Extended Community defined in [RFC9135] is used to signal this color.
The difference between coloring mechanism for EVPN and PBB-EVPN is
that for EVPN, the extended community is advertised with the Ethernet
A-D per ES route whereas for PBB-EVPN, the extended community is
advertised with the B-MAC route.
The subsequent sections detailing Grouping of Ethernet Auto-Discovery
(A-D) per ES and Grouping of B-MAC addresses will be essential for
addressing port failure handling, as discussed in Sections
Section 5.3, Section 5.4, and Section 5.5.
4.2.1. EVPN Route Coloring for vES
When a PE discovers the vESI or is configured with the vESI
associated with its attached vES, an Ethernet-Segment route and
Ethernet A-D per ES route are generated using the vESI identifier.
These Ethernet-Segment and Ethernet A-D per ES routes specific to
each vES are colored with an attribute representing their association
to a physical port (e.g. ENNI).
The corresponding port 'color' is encoded in the EVPN Router's MAC
Extended Community defined in [RFC9135] and advertised along with the
Ethernet Segment and Ethernet A-D per ES routes for this vES. The
color (which is the MAC address of the port) MUST be unique.
The PE also constructs a special Grouping Ethernet A-D per ES route
which represents all the vES associated with the port (e.g. ENNI).
The corresponding port 'color' is encoded in the ESI field. For this
Sajassi, et al. Expires 12 June 2025 [Page 13]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
encoding, Type 3 ESI (Section 5 of [RFC7432]) is used with the MAC
field set to the color (MAC address) of the port and the 3-octet
local discriminator field set to 0xFFFFFF.
The ESI label extended community (Section 7.5 of [RFC7432]) is not
relevant to Grouping Ethernet A-D per ES route. The label value is
not used for encapsulating BUM (Broadcast, Unknown-unicast,
Multicast) packets for any split-horizon function. The ESI label
extended community MUST NOT be added to Grouping Ethernet A-D per ES
route and MUST be ignored on receiving PE.
The Grouping Ethernet Auto-Discovery (A-D) per ES route is advertised
with a list of Route Targets corresponding to the affected service
instances. If the number of associated Route Targets exceeds the
capacity of a single route, multiple Grouping Ethernet A-D per ES
routes are advertised accordingly as specified in Section 8.2 of
[RFC7432].
4.2.2. PBB-EVPN Route Coloring for vES
In PBB-EVPN, particularly when there are a large number of service
instances (i.e., I-SIDs) associated with each EVC, the PE device MAY
assign a color attribute to each vES B-MAC route, indicating their
association with a physical port (e.g., an ENNI).
The corresponding port 'color' is encoded in the EVPN Router's MAC
Extended Community defined in [RFC9135] and advertised along with the
B-MAC for this vES in PBB-EVPN.
The PE MAY then also construct a special Grouping B-MAC route which
represents all the vES associated with the port (e.g. ENNI). The
corresponding port 'color' is encoded directly into this special
Grouping B-MAC route.
5. Failure Handling and Recovery
There are several failure scenarios to consider such as:
A: CE uplink port failure
B: Ethernet Access Network failure
C: PE access-facing port or link failure
D: PE node failure
E: PE isolation from IP/MPLS network
Sajassi, et al. Expires 12 June 2025 [Page 14]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
The solutions specified in [RFC7432], [RFC7623], and [RFC8214]
provide protection against failures as described in these respective
references. In the context of these solutions, the presence of vESes
introduces an additional failure scenario beyond those already
considered, specifically the failure of individual EVCs. Addressing
vES failure scenarios necessitates the independent monitoring of EVCs
or PWs. Upon detection of failure or service restoration,
appropriate DF election and failure recovery mechanisms must be
executed.
[RFC7023] is used for monitoring EVCs and upon failure detection of a
given EVC, DF election procedure per Section 4.1 is executed. For
PBB-EVPN, some extensions are needed to handle the failure and
recovery procedures of [RFC7623] to meet the above requirements.
These extensions are described in the next section.
[RFC4377] and [RFC6310] are used for monitoring the status of LSPs
and/or PWs associated to vES.
B D
|| ||
\/ \/
+-----+
+-----+ | | +---+
| CE1 |EVC2--0=====0--ENNI1| | +-------+
+-----+ | =0--ENNI1|PE1|---| | +---+ +---+
Cust. A | / | | | |IP/MPLS|--|PE3|--|CE4|
+-----+ | / | +---+ |Network| | | +---+
| |EVC2--0== | | | +---+
| CE2 | | | +---+ | |
| |EVC3--0=====0--ENNI2|PE2|---| |
+-----+ | | | | +-------+
+-----+ +---+
/\ /\ /\
|| || ||
A C E
Figure 4: Failure Scenarios A,B,C,D and E
Sajassi, et al. Expires 12 June 2025 [Page 15]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
5.1. EVC Failure Handling for Single-Active vES in EVPN
In [RFC7432], when a DF PE connected to a Single-Active multi-homed
Ethernet Segment loses connectivity to the segment, due to link or
port failure, it signals to the remote PEs to invalidate all MAC
addresses associated with that Ethernet Segment. This is done by
means of a mass-withdraw message, by withdrawing the Ethernet A-D per
ES route. It should be noted that for dual-homing use cases where
there is only a single backup path, MAC invalidating can be avoided
by the remote PEs as they can update their next hop associated with
the affected MAC entries to the backup path per procedure described
in section 8.2 of [RFC7432].
In case of an EVC failure which impacts a single vES, this same EVPN
procedure is used. In this case, the mass-withdraw is conveyed by
withdrawing the Ethernet A-D per vES route carrying the vESI
representing the failed EVC. The remote PEs upon receiving this
message perform the same procedures outlined in section 8.2 of
[RFC7432].
5.2. EVC Failure Handling for Single-Active vES in PBB-EVPN
In [RFC7432] when a PE connected to a Single-Active Ethernet Segment
loses connectivity to the segment, due to link or port failure, it
signals the remote PE to flush all C-MAC addresses associated with
that Ethernet Segment. This is done by updating the advertised a
B-MAC route's MAC Mobility Extended community.
In case of an EVC failure that impacts a single vES, if the above
PBB-EVPN procedure is used, it results in excessive C-MAC flushing
because a single physical port can support large number of EVCs (and
their associated vESes) and thus updating the advertised B-MAC
corresponding to the physical port, with MAC mobility Extended
community, will result in flushing C-MAC addresses not just for the
impacted EVC but for all other EVCs on that port.
To reduce the scope of C-MAC flushing to only the impacted service
instances (the service instance(s) impacted by the EVC failure), the
PBB-EVPN C-MAC flushing needs to be adapted on a per service instance
basis (i.e., per I-SID). [RFC9541] introduces B-MAC/I-SID route
where existing PBB-EVPN B-MAC route is modified to carry an I-SID in
the "Ethernet Tag ID" field instead of NULL value. This field
indicates to the receiving PE, to flush all C-MAC addresses
associated with that I-SID for that B-MAC. This C-MAC flushing
mechanism per I-SID SHOULD be used in case of EVC failure impacting a
vES. Since typically an EVC maps to a single broadcast domain and
thus, a single service instance, the affected PE only needs to
advertise a single B-MAC/I-SID route. However, if the failed EVC
Sajassi, et al. Expires 12 June 2025 [Page 16]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
carries multiple VLANs each with its own broadcast domain, then the
affected PE needs to advertise multiple B-MAC/I-SID routes - one for
each VLAN (broadcast domain) - i.e., one for each I-SID. Each B-MAC/
I-SID route basically instructs the remote PEs to perform flushing
for C-MACs corresponding to the advertised B-MAC only for the
advertised I-SID.
The C-MAC flushing based on B-MAC/I-SID route works fine when there
are only a few VLANs (e.g., I-SIDs) per EVC. However if the number
of I-SIDs associated with a failed EVC is large, then it is
RECOMMENDED to assign a B-MAC per vES and upon EVC failure, the
affected PE simply withdraws this B-MAC message to other PEs.
5.3. Port Failure Handling for Single-Active vESes in EVPN
When many EVCs are aggregated via a single physical port on a PE,
where each EVC corresponds to a vES, then the port failure impacts
all the associated EVCs and their corresponding vESes. If the number
of EVCs corresponding to the Single-Active vESes for that physical
port is in thousands, then thousands of service instances are
impacted. Therefore, the propagation of failure in BGP needs to
address all these impacted service instances. In order to achieve
this, the following extensions are added to the baseline EVPN
mechanism:
1. The PE MAY color each Ethernet A-D per ES route for a given vES,
as described in Section 4.2.1. PE SHOULD use the physical port
MAC by default. The receiving PEs take note of this color and
create a list of vESes for this color.
2. The PE MAY advertises a special Grouping Ethernet A-D per ES
route for that color, which represents all the vES associated
with the port.
3. Upon a port failure (e.g., ENNI failure), the PE MAY send a
mass-withdraw message by withdrawing the Grouping Ethernet A-D
per ES route.
4. When this message is received, the remote PE MAY detect the
special vES mass-withdraw message by identifying the Grouping
Ethernet A-D per ES route. The remote PEs MAY then access the
list created in (1) of the vESes for the specified color, and
initiate locally MAC address invalidating procedures for each of
the vESes in the list.
Sajassi, et al. Expires 12 June 2025 [Page 17]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
In scenarios where a logical ENNI is used the above procedure equally
applies. The logical ENNI is represented by a Grouping Ethernet A-D
per ES where the Type 3 ESI and the 6 bytes used in the ENNI's ESI
MAC address field is used as a color for vESes as described above and
in Section 4.2.1.
5.4. Port Failure Handling for Single-Active vESes in PBB-EVPN
When many EVCs are aggregated via a single physical port on a PE,
where each EVC corresponds to a vES, then the port failure impacts
all the associated EVCs and their corresponding vESes. If the number
of EVCs corresponding to the Single-Active vESes for that physical
port is in thousands, then thousands of service instances (I-SIDs)
are impacted. In such failure scenarios, the following two MAC
flushing mechanisms per [RFC7623] can be performed.
1. If the MAC address of the physical port is used for PBB
encapsulation as B-MAC SA, then upon the port failure, the PE
MUST use the EVPN MAC route withdrawal message to signal the
flush.
2. If the PE shared MAC address is used for PBB encapsulation as
B-MAC SA, then upon the port failure, the PE MUST re-advertise
this MAC route with the MAC Mobility Extended Community to signal
the flush.
The first method is recommended because it reduces the scope of
flushing the most.
As noted above, the advertisement of the extended community along
with B-MAC route for coloring purposes is optional and only
recommended when there are many vESes per physical port and each vES
is associated with very large number of service instances (i.e.,
large number of I-SIDs).
If there are large number of service instances (i.e., I-SIDs)
associated with each EVC, and if there is a B-MAC assigned per vES as
recommended in the above section, then to handle port failure
efficiently, the following extensions are added to the baseline PBB-
EVPN mechanism:
1. Each vES MAY be colored with a MAC address representing the
physical port like the coloring mechanism for EVPN. In other
words, each B-MAC representing a vES is advertised with the
'color' of the physical port per Section 4.2.2. The receiving
PEs take note of this color being advertised along with the B-MAC
route and for each such color, create a list of vESes associated
with this color.
Sajassi, et al. Expires 12 June 2025 [Page 18]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
2. The PE MAY advertise a special Grouping B-MAC route for that
color (consisting by default of port MAC address), which
represents all the vES associated with the port.
3. Upon a port failure (e.g., ENNI failure), the PE MAY send a
mass-withdraw message by withdrawing the Grouping B-MAC route.
4. When this message is received, the remote PE MAY detect the
special vES mass-withdraw message by identifying the Grouping
B-MAC route. The remote PEs MAY then access the list created in
(1) for the specified color, and flush all C-MACs associated with
the failed physical port.
5.5. Fast Convergence in (PBB-)EVPN
As described above, when many EVCs are aggregated via a physical port
on a PE, and where each EVC corresponds to a vES, then the port
failure impacts all the associated EVCs and their corresponding
vESes. Two actions must be taken as the result of such port failure:
* For EVPN initiate mass-withdraw procedure for all vESes associated
with the failed port to invalidate MACs and for PBB-EVPN flush all
C-MACs associated with the failed port across all vESes and the
impacted I-SIDs
* DF election for all impacted vESes associated with the failed port
Section 5.3 already describes how to perform mass-withdraw for all
affected vESes and invalidating MACs using a single BGP withdrawal of
the Grouping Ethernet A-D per ES route. Section 5.4 describes how to
only flush C-MAC address associated with the failed physical port
(e.g., optimum C-MAC flushing) as well as, optionally, the withdrawal
of a Grouping B-MAC route.
This section describes how to perform DF election in the most optimal
way - e.g., to trigger DF election for all impacted vESes (which can
be very large) among the participating PEs via a single BGP message
as opposed to sending large number of BGP messages (one per vES).
This section assumes that the MAC flushing mechanism described in
Section 5.4 is used and route coloring is used.
Sajassi, et al. Expires 12 June 2025 [Page 19]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
+-----+
+----+ | | +---+
| CE1|AC1--0=====0--ENNI1| | +-------+
| |AC2--0 | |PE1|--| |
+----+ |\ ==0--ENNI2| | | |
| \/ | +---+ | |
| /\ | |IP/MPLS|
+----+ |/ \ | +---+ |Network| +---+ +---+
| CE2|AC4--0 =0--ENNI3| | | |---|PE4|--|CE4|
| |AC4--0=====0--ENNI3|PE2|--| | +---+ +---+
+----+ | ====0--ENNI3| | | |
|/ | +---+ | |
0 | | |
+----+ /| | +---+ | |
| CE3|AC5- | | |PE3|--| |
| |AC6--0=====0--ENNI4| | +-------+
+----+ | | +---+
+-----+
Figure 5: Fast Convergence Upon ENNI Failure
As discussed in Section 4.2, it is highly desirable to have a mass
withdraw mechanism similar to the one in [RFC7432] . Although such an
optimization is desirable, it is OPTIONAL. If the optimization is
implemented, the following describes the procedure:
1. When a vES is configured, the PE advertises the Ethernet Segment
route for this vES with a color that corresponds to the
associated physical port.
2. All receiving PEs within the redundancy group record this color
and compile a list of vESes associated with it.
3. Additionally, the PE advertises a Grouping Ethernet A-D per ES
for EVPN, and a Grouping B-MAC for PBB-EVPN, which corresponds to
the color and vES grouping.
4. In the event of a port failure, such as an ENNI failure, the PE
withdraws the previously advertised Grouping Ethernet A-D per ES
or Grouping B-MAC associated with the failed port. The PE should
prioritize sending these Grouping route withdrawal messages over
the withdrawal of individual vES routes affected by the failure.
For instance, as depicted in Figure 5, when the physical port
associated with ENNI3 fails on PE2, it withdraws the previously
advertised Grouping Ethernet A-D per ES route. Upon receiving
Sajassi, et al. Expires 12 June 2025 [Page 20]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
this withdrawal message, other multi-homing PEs (such as PE1 and
PE3) recognize that the vESes associated with CE1 and CE3 are
impacted, based on the associated color, and thus initiate the DF
election procedure for these vESes. Furthermore, remote PEs
(such as PE4), upon receiving this withdrawal message, initiate
the failover procedure for the vESes associated with CE1 and CE3,
and switch to the other PE for each vES redundancy group.
5. On reception of Grouping Ethernet A-D per ES or Grouping B-MAC
route withdrawal, other PEs in the redundancy group initiate DF
election procedures across all their affected vESes.
6. The PE with the physical port failure (ENNI failure), sends vES
route withdrawal for every impacted vES. The other PEs upon
receiving these messages, clear up their BGP tables. It should
be noted the vES route withdrawal messages are not used for
executing DF election procedures by the receiving PEs when
Grouping Ethernet A-D per ES or Grouping B-MAC withdrawal has
been previously received.
6. Acknowledgements
The authors would like to thank Mei Zhang, Jose Liste, and
Luc Andre Burdet for their reviews of this document and feedback.
7. Security Considerations
All the security considerations in [RFC7432] and [RFC7623] apply
directly to this document because this document leverages the control
and data plane procedures described in those documents.
This document does not introduce any new security considerations
beyond that of [RFC7432] and [RFC7623] because advertisements and
processing of Ethernet Segment route for vES in this document follows
that of physical ES in those RFCs.
8. IANA Considerations
This document requests no actions from IANA.
9. References
9.1. Normative References
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119,
DOI 10.17487/RFC2119, March 1997,
<https://www.rfc-editor.org/info/rfc2119>.
Sajassi, et al. Expires 12 June 2025 [Page 21]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
[RFC7432] Sajassi, A., Ed., Aggarwal, R., Bitar, N., Isaac, A.,
Uttaro, J., Drake, J., and W. Henderickx, "BGP MPLS-Based
Ethernet VPN", RFC 7432, DOI 10.17487/RFC7432, February
2015, <https://www.rfc-editor.org/info/rfc7432>.
[RFC7623] Sajassi, A., Ed., Salam, S., Bitar, N., Isaac, A., and W.
Henderickx, "Provider Backbone Bridging Combined with
Ethernet VPN (PBB-EVPN)", RFC 7623, DOI 10.17487/RFC7623,
September 2015, <https://www.rfc-editor.org/info/rfc7623>.
[RFC8174] Leiba, B., "Ambiguity of Uppercase vs Lowercase in RFC
2119 Key Words", BCP 14, RFC 8174, DOI 10.17487/RFC8174,
May 2017, <https://www.rfc-editor.org/info/rfc8174>.
[RFC8214] Boutros, S., Sajassi, A., Salam, S., Drake, J., and J.
Rabadan, "Virtual Private Wire Service Support in Ethernet
VPN", RFC 8214, DOI 10.17487/RFC8214, August 2017,
<https://www.rfc-editor.org/info/rfc8214>.
[RFC8365] Sajassi, A., Ed., Drake, J., Ed., Bitar, N., Shekhar, R.,
Uttaro, J., and W. Henderickx, "A Network Virtualization
Overlay Solution Using Ethernet VPN (EVPN)", RFC 8365,
DOI 10.17487/RFC8365, March 2018,
<https://www.rfc-editor.org/info/rfc8365>.
[RFC9135] Sajassi, A., Salam, S., Thoria, S., Drake, J., and J.
Rabadan, "Integrated Routing and Bridging in Ethernet VPN
(EVPN)", RFC 9135, DOI 10.17487/RFC9135, October 2021,
<https://www.rfc-editor.org/info/rfc9135>.
[RFC9541] Rabadan, J., Ed., Sathappan, S., Nagaraj, K., Miyake, M.,
and T. Matsuda, "Flush Mechanism for Customer MAC
Addresses Based on Service Instance Identifier (I-SID) in
Provider Backbone Bridging EVPN (PBB-EVPN)", RFC 9541,
DOI 10.17487/RFC9541, March 2024,
<https://www.rfc-editor.org/info/rfc9541>.
9.2. Informative References
[MEF63] Metro Ethernet Forum, MEF., "[MEF6.3]: Subscriber Ethernet
Services Definitions", 2019.
[RFC4377] Nadeau, T., Morrow, M., Swallow, G., Allan, D., and S.
Matsushima, "Operations and Management (OAM) Requirements
for Multi-Protocol Label Switched (MPLS) Networks",
RFC 4377, DOI 10.17487/RFC4377, February 2006,
<https://www.rfc-editor.org/info/rfc4377>.
Sajassi, et al. Expires 12 June 2025 [Page 22]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
[RFC6310] Aissaoui, M., Busschbach, P., Martini, L., Morrow, M.,
Nadeau, T., and Y. Stein, "Pseudowire (PW) Operations,
Administration, and Maintenance (OAM) Message Mapping",
RFC 6310, DOI 10.17487/RFC6310, July 2011,
<https://www.rfc-editor.org/info/rfc6310>.
[RFC7023] Mohan, D., Ed., Bitar, N., Ed., Sajassi, A., Ed., DeLord,
S., Niger, P., and R. Qiu, "MPLS and Ethernet Operations,
Administration, and Maintenance (OAM) Interworking",
RFC 7023, DOI 10.17487/RFC7023, October 2013,
<https://www.rfc-editor.org/info/rfc7023>.
[RFC7080] Sajassi, A., Salam, S., Bitar, N., and F. Balus, "Virtual
Private LAN Service (VPLS) Interoperability with Provider
Backbone Bridges", RFC 7080, DOI 10.17487/RFC7080,
December 2013, <https://www.rfc-editor.org/info/rfc7080>.
[RFC7209] Sajassi, A., Aggarwal, R., Uttaro, J., Bitar, N.,
Henderickx, W., and A. Isaac, "Requirements for Ethernet
VPN (EVPN)", RFC 7209, DOI 10.17487/RFC7209, May 2014,
<https://www.rfc-editor.org/info/rfc7209>.
[RFC8584] Rabadan, J., Ed., Mohanty, S., Ed., Sajassi, A., Drake,
J., Nagaraj, K., and S. Sathappan, "Framework for Ethernet
VPN Designated Forwarder Election Extensibility",
RFC 8584, DOI 10.17487/RFC8584, April 2019,
<https://www.rfc-editor.org/info/rfc8584>.
[RFC9252] Dawra, G., Ed., Talaulikar, K., Ed., Raszuk, R., Decraene,
B., Zhuang, S., and J. Rabadan, "BGP Overlay Services
Based on Segment Routing over IPv6 (SRv6)", RFC 9252,
DOI 10.17487/RFC9252, July 2022,
<https://www.rfc-editor.org/info/rfc9252>.
Authors' Addresses
Ali Sajassi
Cisco Systems
Email: sajassi@cisco.com
Patrice Brissette
Cisco Systems
Email: pbrisset@cisco.com
Rick Schell
Verizon
Sajassi, et al. Expires 12 June 2025 [Page 23]
Internet-Draft EVPN Virtual Ethernet Segment December 2024
Email: richard.schell@verizon.com
John E Drake
Juniper
Email: jdrake@juniper.net
Jorge Rabadan
Nokia
Email: jorge.rabadan@nokia.com
Sajassi, et al. Expires 12 June 2025 [Page 24]