EVPN VPWS Flexible Cross-Connect Service
draft-ietf-bess-evpn-vpws-fxc-09

Document Type Active Internet-Draft (bess WG)
Authors Ali Sajassi , Patrice Brissette , Jim Uttaro , John Drake , Sami Boutros , Jorge Rabadan
Last updated 2024-10-04 (Latest revision 2024-09-19)
Replaces draft-sajassi-bess-evpn-vpws-fxc
RFC stream Internet Engineering Task Force (IETF)
Intended RFC status Proposed Standard
Formats
Reviews
Additional resources Mailing list discussion
Stream WG state Submitted to IESG for Publication
Document shepherd Stephane Litkowski
Shepherd write-up Show Last changed 2022-06-16
IESG IESG state Waiting for AD Go-Ahead
Action Holder
Consensus boilerplate Yes
Telechat date (None)
Responsible AD Gunter Van de Velde
Send notices to slitkows.ietf@gmail.com
IANA IANA review state IANA OK - Actions Needed
draft-ietf-bess-evpn-vpws-fxc-09
BESS Working Group                                       A. Sajassi, Ed.
Internet-Draft                                              P. Brissette
Intended status: Standards Track                           Cisco Systems
Expires: 23 March 2025                                         J. Uttaro
                                                                    AT&T
                                                                J. Drake
                                                        Juniper Networks
                                                              S. Boutros
                                                                   Ciena
                                                              J. Rabadan
                                                                   Nokia
                                                       19 September 2024

                EVPN VPWS Flexible Cross-Connect Service
                    draft-ietf-bess-evpn-vpws-fxc-09

Abstract

   This document describes a new EVPN VPWS service type specifically for
   multiplexing multiple attachment circuits across different Ethernet
   Segments and physical interfaces into a single EVPN VPWS service
   tunnel and still providing Single-Active and All-Active multi-homing.
   This new service is referred to as flexible cross-connect service.
   After a description of the rationale for this new service type, the
   solution to deliver such service is detailed.

Requirements Language

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
   "OPTIONAL" in this document are to be interpreted as described in BCP
   14 [RFC2119] [RFC8174] when, and only when, they appear in all
   capitals, as shown here.

Status of This Memo

   This Internet-Draft is submitted in full conformance with the
   provisions of BCP 78 and BCP 79.

   Internet-Drafts are working documents of the Internet Engineering
   Task Force (IETF).  Note that other groups may also distribute
   working documents as Internet-Drafts.  The list of current Internet-
   Drafts is at https://datatracker.ietf.org/drafts/current/.

Sajassi, et al.           Expires 23 March 2025                 [Page 1]
Internet-Draft      EVPN VPWS Flexible Cross-Connect      September 2024

   Internet-Drafts are draft documents valid for a maximum of six months
   and may be updated, replaced, or obsoleted by other documents at any
   time.  It is inappropriate to use Internet-Drafts as reference
   material or to cite them other than as "work in progress."

   This Internet-Draft will expire on 23 March 2025.

Copyright Notice

   Copyright (c) 2024 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents (https://trustee.ietf.org/
   license-info) in effect on the date of publication of this document.
   Please review these documents carefully, as they describe your rights
   and restrictions with respect to this document.  Code Components
   extracted from this document must include Revised BSD License text as
   described in Section 4.e of the Trust Legal Provisions and are
   provided without warranty as described in the Revised BSD License.

Table of Contents

   1.  Introduction  . . . . . . . . . . . . . . . . . . . . . . . .   3
     1.1.  Terminology . . . . . . . . . . . . . . . . . . . . . . .   3
   2.  Requirements  . . . . . . . . . . . . . . . . . . . . . . . .   5
   3.  Solution  . . . . . . . . . . . . . . . . . . . . . . . . . .   6
     3.1.  VPWS Service Identifiers  . . . . . . . . . . . . . . . .   7
     3.2.  Default Flexible Xconnect . . . . . . . . . . . . . . . .   8
       3.2.1.  Multi-homing  . . . . . . . . . . . . . . . . . . . .   9
     3.3.  VLAN-Signaled Flexible Xconnect . . . . . . . . . . . . .   9
       3.3.1.  Local Switching . . . . . . . . . . . . . . . . . . .  10
     3.4.  Service Instantiation . . . . . . . . . . . . . . . . . .  11
   4.  BGP Extensions  . . . . . . . . . . . . . . . . . . . . . . .  11
   5.  Failure Scenarios . . . . . . . . . . . . . . . . . . . . . .  12
     5.1.  EVPN VPWS Service Failure . . . . . . . . . . . . . . . .  14
     5.2.  Attachment Circuit Failure  . . . . . . . . . . . . . . .  14
     5.3.  PE Port Failure . . . . . . . . . . . . . . . . . . . . .  15
     5.4.  PE Node Failure . . . . . . . . . . . . . . . . . . . . .  15
   6.  Security Considerations . . . . . . . . . . . . . . . . . . .  15
   7.  IANA Considerations . . . . . . . . . . . . . . . . . . . . .  16
   8.  References  . . . . . . . . . . . . . . . . . . . . . . . . .  16
     8.1.  Normative References  . . . . . . . . . . . . . . . . . .  16
     8.2.  Informative References  . . . . . . . . . . . . . . . . .  16
   Appendix A.  Contributors . . . . . . . . . . . . . . . . . . . .  17
   Authors' Addresses  . . . . . . . . . . . . . . . . . . . . . . .  17

Sajassi, et al.           Expires 23 March 2025                 [Page 2]
Internet-Draft      EVPN VPWS Flexible Cross-Connect      September 2024

1.  Introduction

   [RFC8214] describes a solution to deliver P2P services using BGP
   constructs defined in [RFC7432].  It delivers this P2P service
   between a pair of Attachment Circuits (ACs), where an AC can
   designate on a PE, a port, a VLAN on a port, or a group of VLANs on a
   port.  It also leverages multi-homing and fast convergence
   capabilities of [RFC7432] in delivering these VPWS services.
   Multi-homing capabilities include the support of single-active and
   all-active redundancy mode and fast convergence is provided using
   "mass withdrawal" message in control-plane and fast protection
   switching using prefix independent convergence in data-plane upon
   node or link failure [I-D.ietf-rtgwg-bgp-pic].  Furthermore, the use
   of EVPN BGP constructs eliminates the need for multi-segment PW
   auto-discovery and signaling if the VPWS service need to span across
   multiple ASes [RFC5659].

   Some service providers have very large number of ACs (in millions)
   that need to be back hauled across their MPLS/IP network.  These ACs
   may or may not require tag manipulation (e.g., VLAN translation).
   These service providers want to multiplex a large number of ACs
   across several physical interfaces spread across one or more PEs
   (e.g., several Ethernet Segments) onto a single VPWS service tunnel
   in order to a) reduce number of EVPN service labels associated with
   EVPN-VPWS service tunnels and thus the associated OAM monitoring, and
   b) reduce EVPN BGP signaling (e.g., not to signal each AC as it is
   the case in [RFC8214]).

   These service provider want the above functionality without
   scarifying any of the capabilities of [RFC8214] including single-
   active and all-active multi-homing, and fast convergence.

   This document presents a solution based on extensions to [RFC8214] to
   meet the above requirements.

1.1.  Terminology

   AC:    Attachment Circuit

   CE:    Customer Edge device e.g., host or router or switch

   EPL:   Ethernet Private Line

   ES:    Ethernet Segment

   ESI:   Ethernet Segment Identififer

   EVI:   EVPN Instance Identifier

Sajassi, et al.           Expires 23 March 2025                 [Page 3]
Internet-Draft      EVPN VPWS Flexible Cross-Connect      September 2024

   EVPL:  Ethernet Virtual Private Line

   EVPN:  Ethernet Virtual Private Network

   Ethernet A-D:  Ethernet Auto-Discovery (A-D) per EVI and Ethernet A-D
      per ESI routes, as defined in [RFC7432] and [RFC8214].

   FXC:   Flexible Cross Connect

   L2:   Layer 2

   MAC:   Media Access Control

   MPLS:  Multi Protocol Label Switching

   MTU:   Maximum Transmit Unit

   OAM:   Operations, Administration and Maintenance

   PE:   Provider Edge device

   PW:   Pseudowire

   RT:   Route Target

   VCCV:  Virtual circuit connection verification

   VID:   Vlan ID

   VPWS:  Virtual private wire service

   VRF:   Virtual Route Forwarding

   VPWS Service Tunnel:  It is represented by a pair of EVPN service
      labels associated with a pair of endpoints.  Each label is
      downstream assigned and advertised by the disposition PE through
      an Ethernet Auto-Discovery (A-D) per EVI route.  The downstream
      label identifies the endpoint on the disposition PE.  A VPWS
      service tunnel can be associated with many VPWS service
      identifiers where each identifier is a normalized VID.

   Single-Active Redundancy Mode:  When a device or a network is
      multi-homed to two or more PEs and when only a single PE in such
      redundancy group can forward traffic to/from the multi-homed
      device or network for a given VLAN, then such multi-homing or
      redundancy is referred to as "Single-Active".

   All-Active Redundancy Mode:  When a device is multi-homed to two or

Sajassi, et al.           Expires 23 March 2025                 [Page 4]
Internet-Draft      EVPN VPWS Flexible Cross-Connect      September 2024

      more PEs and when all PEs in such redundancy group can forward
      traffic to/from the multi-homed device for a given VLAN, then such
      multi-homing or redundancy is referred to as "All-Active".

2.  Requirements

   Two of the main motivations for service providers seeking a new
   solution are: 1) to reduce number of VPWS service tunnels by
   multiplexing large number of ACs across different physical interfaces
   instead of having one VPWS service tunnel per AC, and 2) to reduce
   the signaling of ACs as much as possible.  Besides these two
   requirements, they also want multi-homing and fast convergence
   capabilities of [RFC8214].

   In [RFC8214], a PE signals an AC indirectly by first associating that
   AC to a VPWS service tunnel (e.g., a VPWS service instance) and then
   signaling the VPWS service tunnel via a Ethernet A-D per EVI route
   with Ethernet Tag field set to a 24-bit VPWS service instance
   identifier (which is unique within the EVI) and ESI field set to a
   10-octet identifier of the Ethernet Segment corresponding to that AC.

   Therefore, a PE device that receives such EVPN routes, can associate
   the VPWS service tunnel to the remote Ethernet Segment using the ESI
   field, and when the remote ES fails and the PE receives the "mass
   withdrawal" message associated with the failed ES per [RFC7432], it
   can quickly update its BGP list of available remote entries to
   invalidate all VPWS service tunnels sharing the ESI field and achieve
   fast convergence for multi-homing scenarios.  Even if fast
   convergence were not needed, there would still be a need for
   signaling each AC failure (via its corresponding VPWS service tunnel)
   associated with the failed ES, so that the BGP path list for each of
   them gets updated accordingly and the packets are sent to backup PE
   (in case of single- active multi-homing) or to other PEs in the
   redundancy group (in case of all-active multi-homing).  In absence of
   updating the BGP path list, the traffic for that VPWS service tunnel
   will be black-holed.

   When a single VPWS service tunnel carries multiple ACs across various
   Ethernet Segments (physical interfaces) without signaling the ACs via
   EVPN BGP to remote PE devices, those remote PE devices lack the
   information to associate the received Ethernet Segment with these ACs
   or with their local ACs.  They also lack the association between the
   VPWS service tunnel (e.g., EVPN service label) and the far-end ACs.
   This means that while the remote PEs can associate their local ACs
   with the VPWS service tunnel, they cannot make similar associations
   for the far-end ACs.
   Consequently, in case of a connectivity failure to the ES, the remote
   PEs are unable to redirect traffic via another multi-homing PE to

Sajassi, et al.           Expires 23 March 2025                 [Page 5]
Internet-Draft      EVPN VPWS Flexible Cross-Connect      September 2024

   that ES.  In other words, even if an ES failure is signaled via EVPN
   to the remote PE devices, they cannot effectively respond because
   they do not know the relationship between the remote ES, the remote
   ACs, and the VPWS service tunnel.

   To address this issue when multiplexing a large number of ACs onto a
   single VPWS service tunnel, two mechanisms have been developed: one
   to support VPWS services between two single-homed endpoints, and
   another to support VPWS services where one of the endpoints is multi-
   homed.

   For single-homed endpoints, it is acceptable not to signal each AC in
   BGP because, in the event of a connection failure to the ES, there is
   no alternative path to that endpoint.  However, the implication of
   not signaling an AC failure is that the traffic destined for the
   failed AC is sent over the MPLS/IP core and then discarded at the
   destination PE, thereby potentially wasting network resources.
   This waste of network resources during a connection failure may be
   transient, as it can be detected and prevented at the application
   layer in certain cases.  Section 3.2 outlines a solution for such
   single-homing VPWS services.

   For VPWS services where one of the endpoints is multi-homed, there
   are two options:

   1) to signal each AC via BGP, allowing the path list to be updated
   upon a failure affecting those ACs.  This solution is described in
   Section 3.3 and is referred to as the VLAN-signaled flexible cross-
   connect service.

   2) to bundle several ACs on an ES together per destination endpoint
   (e.g., ES, MAC-VRF, etc.) and associate such a bundle with a single
   VPWS service tunnel.  This approach is similar to the VLAN-bundle
   service interface described in [RFC8214].  This solution is described
   in Section 3.2.1.

3.  Solution

   This section outlines a solution for providing a new VPWS service
   between two PE devices where a large number of ACs (such as VLANs)
   that span across multiple Ethernet Segments (physical interfaces) on
   each PE are multiplexed onto a single P2P EVPN service tunnel.  Since
   the multiplexing involves several physical interfaces, there can be
   overlapping VLAN IDs across these interfaces.  In such cases, the
   VLAN IDs (VIDs) must be translated into unique VIDs to prevent
   collisions.  Furthermore, if the number of VLANs being multiplexed
   onto a single VPWS service tunnel exceeds 4095, then a single tag to
   double tag translation must be performed.  This translation of VIDs

Sajassi, et al.           Expires 23 March 2025                 [Page 6]
Internet-Draft      EVPN VPWS Flexible Cross-Connect      September 2024

   into unique VIDs (either single or double) is referred to as "VID
   normalization".

   When a single normalized VID is used, the lower 12 bits of the
   Ethernet tag field in EVPN routes MUST be set to that VID.  When a
   double normalized VID is used, the lower 12 bits of the Ethernet tag
   field MUST be set to the inner VID, while the higher 12 bits are set
   to the outer VID.  As stated in [RFC8214], 12-bit and 24-bit VPWS
   service instance identifiers representing normalized VIDs MUST be
   right-aligned.

   Since there is only a single EVPN VPWS service tunnel associated with
   many normalized VIDs (either single or double) across multiple
   physical interfaces, an MPLS lookup at the disposition PE is no
   longer sufficient to forward the packet to the correct egress
   endpoint or interface.  Therefore, in addition to an EVPN label
   lookup corresponding to the VPWS service tunnel, a VID lookup (either
   single or double) is also required.  At the disposition PE, the EVPN
   label lookup identifies a VID-VRF, and the lookup of the normalized
   VID(s) within that table identifies the appropriate egress endpoint
   or interface.  The tag manipulation (translation from normalized
   VID(s) to the local VID) SHOULD be performed either as part of the
   VID table lookup or at the egress interface itself.

   Since the VID lookup (single or double) needs to be performed at the
   disposition PE, VID normalization MUST be completed prior to MPLS
   encapsulation on the ingress PE.  This requires that both the
   imposition and disposition PE devices be capable of VLAN tag
   manipulation, such as rewriting (single or double), addition, or
   deletion (single or double) at their endpoints (e.g., their ESs, MAC-
   VRFs, IP-VRFs, etc.).  Operators should be informed of potential
   trade-offs from a performance standpoint, compared to typical PW
   processing.

3.1.  VPWS Service Identifiers

   In [RFC8214], a unique value identifying the service is signaled in
   the context of each PE's EVI.  The 32-bit Ethernet Tag ID field MUST
   be set to this VPWS service instance identifier value.  Translation
   at an ASBR is needed if re-advertising to another AS affects
   uniqueness.

   For FXC, this same Ethernet Tag ID field value is an identifier which
   may represent:

   *  VLAN-Bundle : a unique value for a group of VLANs ;

Sajassi, et al.           Expires 23 March 2025                 [Page 7]
Internet-Draft      EVPN VPWS Flexible Cross-Connect      September 2024

   *  VLAN-Aware Bundle : a unique value for individual VLANs, and is
      considered same as the normalised VID.

   Both the VPWS service instance identifier and normalised VID are
   carried in the Ethernet Tag ID field of the Ethernet A-D per EVI
   route.  For FXC, in the case of a 12-bit ID the VPWS service instance
   identifier is the same as the single-tag normalised VID and will be
   the same on both VPWS service endpoints.  Similarly in the case of a
   24-bit ID, the VPWS service instance identifier is the same as the
   double-tag normalised VID.

3.2.  Default Flexible Xconnect

   In this mode of operation, many ACs across several Ethernet Segments
   are multiplexed into a single EVPN VPWS service tunnel represented by
   a single VPWS service ID.  This is the default mode of operation for
   FXC and the participating PEs do not need to signal the VLANs
   (normalized VIDs) in EVPN BGP.

   Regarding the data-plane aspects of this solution, both imposition
   and disposition Provider Edge (PE) devices MUST be aware of the VLANs
   as the imposition PE performs VID normalization and the disposition
   PE carries out VID lookup and translation.  There SHOULD ideally be a
   single point-to-point (P2P) EVPN VPWS service tunnel between a pair
   of PEs for a specific set of Attachment Circuits (ACs).

   As previously mentioned, because the EVPN VPWS service tunnel is
   employed to multiplex ACs across various Ethernet Segments (ESs) or
   physical interfaces, the EVPN label alone is not sufficient for
   accurate forwarding of the received packets over the MPLS/IP network
   to egress interfaces.  Therefore, normalized VID lookup is REQUIRED
   in the disposition direction to forward packets to their proper
   egress end-points; the EVPN label lookup identifies a VID-VRF, and a
   subsequent normalized VID lookup in that table identifies the egress
   interface.

   In this solution, for each PE, the single-homing ACs represented by
   their normalized VIDs are associated with a single VPWS service
   instance within a specific EVI.  The generated EVPN route is an
   Ethernet A-D per EVI route with and ESI of 0, and Ethernet Tag field
   set to the VPWS service instance ID, and the MPLS label field set to
   a dynamically generated EVPN service label representing the EVPN VPWS
   service tunnel.  This route is sent with a Route Target (RT) that
   represents the EVI, which can be auto-generated from the EVI
   according to Section 5.1.2.1 of [RFC8365].  Additionally, this route
   is sent with the EVPN Layer-2 Extended Community defined in
   Section 3.1 of [RFC8214] with two new flags (outlined in Section 4)
   that indicate: 1) this VPWS service tunnel is for the default

Sajassi, et al.           Expires 23 March 2025                 [Page 8]
Internet-Draft      EVPN VPWS Flexible Cross-Connect      September 2024

   Flexible Cross-Connect, and 2) the normalized VID type (single versus
   double).  The receiving PE uses these new flags for a consistency
   check and MAY generate an alarm if it detects inconsistencies, but it
   will not disrupt the VPWS service.

   It should be noted that in this mode of operation, a single
   Ethernet A-D per EVI route is transmitted upon the configuration of
   the first Attachment Circuit (AC) with the normalized VID.  As
   additional ACs are configured and associated with this EVPN VPWS
   service tunnel, the PE does not advertise any additional EVPN BGP
   routes and only associates locally these ACs with the pre-established
   VPWS service tunnel.

3.2.1.  Multi-homing

   The default FXC mode can also be used for multi-homing.  In this
   mode, a group of normalized VIDs representing ACs on a single
   Ethernet Segment, all destined to a single endpoint, are multiplexed
   into a single EVPN VPWS service tunnel which is identified by a
   unique VPWS service ID.  When employing the default FXC mode for
   multi-homing, rather than using a single EVPN VPWS service tunnel
   there may be multiple service tunnels per pair of PEs.  Specifically,
   there is one tunnel for each group of VIDs per pair of PEs, and there
   can be many such groups between a pair of PEs, resulting in numerous
   EVPN service tunnels.

3.3.  VLAN-Signaled Flexible Xconnect

   In this mode of operation, similar to the default FXC mode described
   in Section 3.2, many normalized VIDs representing ACs across several
   Ethernet Segments/interfaces are multiplexed into a single EVPN VPWS
   service tunnel.  However, this single tunnel is represented by
   multiple VPWS service IDs (one per normalized VID) and these
   normalized VIDs are signaled using EVPN BGP.

   In this solution, on each Provider Edge (PE), the multi-homing ACs
   represented by their normalized VIDs are configured with a single
   EVI.  There is no need to configure a separate VPWS service instance
   ID in here, as it corresponds to the normalized VID.  For each
   normalized VID on each Ethernet Segment, the PE generates an Ethernet
   A-D per EVI route where the ESI field represents the ES ID, the
   Ethernet Tag field is set to the normalized VID, and the MPLS label
   field is set to a dynamically generated EVPN label representing the
   P2P EVPN service tunnel.  This label is the same for all ACs
   multiplexed into a single EVPN VPWS service tunnel.  This route is
   sent with a Route Target (RT) representing the EVI.  As before, this
   RT can be auto-generated from the EVI per section Section 5.1.2.1 of
   [RFC8365].  Additionally, this route includes the EVPN Layer-2

Sajassi, et al.           Expires 23 March 2025                 [Page 9]
Internet-Draft      EVPN VPWS Flexible Cross-Connect      September 2024

   Extended Community defined in Section 3.1 of [RFC8214] with two new
   flags (outlined in Section 4) that indicate: 1) this VPWS service
   tunnel is for VLAN-signaled Flexible Cross-Connect, and 2) the
   normalized VID type (single versus double).  The receiving PE uses
   these new flags for a consistency check and may generate an alarm if
   it detects inconsistency, but it will not disrupt the VPWS service.

   It should be noted that in this mode of operation, the PE sends a
   single Ethernet A-D per EVI route for each AC that is configured.
   Each normalized VID that is configured per ES results in generation
   of an Ethernet A-D per EVI.

   This mode of operation enabled automatic cross-checking of normalized
   VIDs used for Ethernet Virtual Private Line (EVPL) services because
   these VIDs are signaled in EVPN BGP.  For instance, if the same
   normalized VID is configured on three PE devices (instead of two) for
   the same EVI, then when a PE receives the second remote Ethernet A-D
   per EVI route, it generates an error message unless the two Ethernet
   A-D per EVI routes include the same ESI.  Such cross-checking is not
   feasible in the default FXC mode because the normalized VIDs are not
   signaled.

3.3.1.  Local Switching

   When cross-connection occurs between two ACs belonging to two multi-
   homed Ethernet Segments on the same set of multi-homing PEs, the
   forwarding between the two ACs must be performed locally during
   normal operation (e.g., in absence of a local link failure).  This
   means that traffic between the two ACs MUST be locally switched
   within the PE.

   In terms of control plane processing, this means that when the
   receiving PE processes an Ethernet A-D per EVI route whose ESI is a
   local ESI, the PE does not modify its forwarding state based on the
   received route.  This approach ensures that local switching takes
   precedence over forwarding via the MPLS/IP network.  This method of
   prioritizing locally switched traffic aligns with the baseline EVPN
   principles described in [RFC7432], where locally switched preference
   is specified for MAC/IP routes.

Sajassi, et al.           Expires 23 March 2025                [Page 10]
Internet-Draft      EVPN VPWS Flexible Cross-Connect      September 2024

   In such scenarios, the Ethernet A-D per EVI route should be
   advertised with the MPLS label either associated with the destination
   Attachment Circuit or with the destination Ethernet Segment in order
   to avoid any ambiguity in forwarding.  In other words, the MPLS label
   cannot represent the same VID-VRF outlined in Section 3.3, as the
   same normalized VID can be reachable via two Ethernet Segments.  In
   the case of using an MPLS label per destination AC, this approach can
   also be applied to VLAN-based VPWS or VLAN-bundle VPWS services as
   per [RFC8214].

3.4.  Service Instantiation

   The V field defined in Section 4 is OPTIONAL.  However, if
   transmitted, its value may indicate an error condition that could
   lead to operational issues.  In such cases, merely notifying the
   operator of an error is insufficient; the VPWS service tunnel must
   not be established.

   If both endpoints of a VPWS tunnel are signaling a matching
   Normalised VID in the control plane, but one is operating in single-
   tag mode and the other in double-tag mode, the signaling of the V-bit
   facilitates the detection and prevention of this tunnel's
   instantiation.

   If single VID normalization is signaled in the Ethernet Tag ID field
   (12 bits) yet dataplane is operating based on double tags, the VID
   normalization applies only to outer tag.  Conversely, if double VID
   normalization is signaled in the Ethernet Tag ID field (24 bits), VID
   normalization applies to both the inner and outer tags.

4.  BGP Extensions

   This draft uses the EVPN Layer-2 attribute extended community as
   defined in [RFC8214] with two additional flags incorporated into this
   Extended Community (EC) as detailed below.  This EC is sent with
   Ethernet A-D per EVI route per Section 3, and SHOULD be sent for both
   Single-Active and All-Active redundancy modes.

Sajassi, et al.           Expires 23 March 2025                [Page 11]
Internet-Draft      EVPN VPWS Flexible Cross-Connect      September 2024

       +-------------------------------------------+
       | Type (0x06) / Sub-type (0x04) (2 octets)  |
       +-------------------------------------------+
       | Control Flags (2 octets)                  |
       +-------------------------------------------+
       | L2 MTU (2 octets)                         |
       +-------------------------------------------+
       | Reserved (2 octets)                       |
       +-------------------------------------------+

                            1 1 1 1 1 1
        0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5
       +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
       | MBZ           | V | M |-|C|P|B|    (MBZ = MUST Be Zero)
       +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   The following bits in the Control Flags are defined; the remaining
   bits MUST be set to zero when sending and MUST be ignored when
   receiving this community.

       Name     Meaning
       ---------------------------------------------------------------
       B,P,C    per definition in [RFC8214]

       -        reserved for Flow-label

       M        00 mode of operation as defined in [RFC8214]
                01 VLAN-Signaled FXC
                10 Default FXC

       V        00 operating per [RFC8214]
                01 single-VID normalization
                10 double-VID normalization

   The M and V fields are OPTIONAL.  The M field is ignored at reception
   for forwarding purposes and is used for error notifications.

5.  Failure Scenarios

   Two examples will be used as an example to analyze the failure
   scenarios.

   The first scenario is a default Flexible Xconnect with Multi-Homing
   solution and it is depicted in Figure 1.  In this case, VID
   Normalization is performed and a single Ethernet A-D per EVI route is

Sajassi, et al.           Expires 23 March 2025                [Page 12]
Internet-Draft      EVPN VPWS Flexible Cross-Connect      September 2024

   sent for the bundle of ACs on an ES.  That is, PE1 will advertise two
   Ethernet A-D per EVI routes: the first one will identify the ACs on
   port p1's ES and the second one will identify the AC2 in port p2's
   ES.  Similarly, PE2 will advertise two Ethernet A-D per EVI routes.

                    N.VID 1,2,3 +---------------------+
                            PE1 |                     |
                        +---------+     IP/MPLS       |
      +-----+ VID1   p1 | +-----+ | sv.T1             +
      | CE1 |-------------| FXC |======+            PE3         +-----+
      |     |        /\ | |     | |    \     +----------+    +--| CE3 |
      +-----+\      +||---|     | sv.T2 \    |          |  1/   |     |
          VID3\    / ||---|     |=====+  \   | +-----+  |  /    +-----+
               \  // \/ | +-----+ |    \  +====| FXC |----+
                \ /  p2 +---------+     +======|     |  |   2   +-----+
                /\                           | |     |----------| CE4 |
               / /\    +---------+       +=====|     |  |       |     |
              / /  \p3 | +-----+ sv.T3  / +====|     |  |       +-----+
       VIDs1,2 /    +----| FXC |=======+ /   | |     |---+
      +-----+ /   /\   | |     | |      /    | +-----+  |\3    +-----+
      | CE2 |-----||---| |     | sv.T4 /     |          | \    | CE5 |
      |     |-----||---| |     |======+      +----------+  +---|     |
      +--VIDs3,4  \/   | +-----+ |                  |          +-----+
                  p4   +---------+                  |
                            PE2 |                   |
                    N.VID 1,2,3 +-------------------+

                    Figure 1: Default Flexible Xconnect

   The second scenario, depicted in Figure 2, illustrates the
   VLAN-signaled FXC mode with Multi-Homing.  In this example:

   *  CE1 is connected to PE1 and PE2 via (port,VID)=(p1,1) and (p3,3),
      respectively.  CE1's VIDs are normalized to value 1 on both PEs,
      and CE1 is cross-connected to CE3's VID 1 at the remote end.

   *  CE2 is connected to PE1 and PE2 via ports p2 and p4 respectively:

      -  The combinations (p2,1) and (p4,3) identify the ACs used to
         cross-connect CE2 to CE4's VID 2, and are normalized to
         value 2.

      -  The combinations (p2,2) and (p4,4) identify the ACs used to
         cross-connect CE2 to CE5's VID 3, and are normalized to
         value 3.

Sajassi, et al.           Expires 23 March 2025                [Page 13]
Internet-Draft      EVPN VPWS Flexible Cross-Connect      September 2024

   In this scenario, PE1 and PE2 advertise an Ethernet A-D per EVI route
   for each normalized VID (values 1, 2 and 3).  However, only two VPWS
   Service Tunnels are required: VPWS Service Tunnel 1 (sv.T1) between
   PE1's FXC service and PE3's FXC, and VPWS Service Tunnel 2 (sv.T2)
   between PE2's FXC and PE3's FXC.

                    N.VID 1,2,3 +---------------------+
                            PE1 |                     |
                        +---------+     IP/MPLS       |
       +-----+ VID1  p1 | +-----+ |                   +
       | CE1 |------------| FXC | |     sv.T1       PE3          +-----+
       |     |       /\ | |     |=======+     +----------+    +--| CE3 |
       +-----+\     +||---|     | |     \     |          |  1/   |     |
           VID3\   / ||---|     | |      \    | +-----+  |  /    +-----+
                \ / /\/ | +-----+ |       +=====| FXC |----+
                 \ / p2 +---------+           | |     |  |   2   +-----+
                 /\                           | |     |----------| CE4 |
                / /\    +---------+      +======|     |  |       |     |
               / /  \p3 | +-----+ |     /     | |     |  |       +-----+
        VIDs1,2 /    +----| FXC |      /      | |     |---+
       +-----+ /   /\   | |     |======+      | +-----+  |\3    +-----+
       | CE2 |-----||-----|     | |     sv.T2 |          | \    | CE5 |
       |     |-----||-----|     | |           +----------+  +---|     |
       +-----+     \/   | +-----+ |                 |           +-----+
          VIDs3,4  p4   +---------+                 |
                             PE2 |                  |
                     N.VID 1,2,3 +------------------+

                 Figure 2: VLAN-Signaled Flexible Xconnect

5.1.  EVPN VPWS Service Failure

   The failure detection of an EVPN VPWS service can be performed via
   OAM mechanisms such as VCCV-BFD and upon such failure detection, the
   switch over procedure to the backup S-PE is the same as the one
   described above.

5.2.  Attachment Circuit Failure

   In the event of an AC failure, the VLAN-Signaled and default FXC
   modes exhibit distinct behaviors:

Sajassi, et al.           Expires 23 March 2025                [Page 14]
Internet-Draft      EVPN VPWS Flexible Cross-Connect      September 2024

   *  Default FXC (Figure 1): in the default mode, a VLAN or AC failure
      is not signaled.  Consequently, in case of an AC failure such as
      VID1 on CE2, there is nothing to prevent PE3 from directing
      traffic from CE4 to PE1, leading to a potential black hole.
      Application layer Operations, Administration, and Maintenance
      (OAM) may be utilized if per-VLAN fault propagation is necessary
      in this scenario.

   *  VLAN-Signaled FXC (Figure 2): in the case of a VLAN or AC failure
      such as VID1 on CE2, triggers the withdrawal of the Ethernet A-D
      per EVI route for the corresponding Normalized VID, specifically
      Ethernet-Tag 2.  Upon receiving the route withdrawal, PE3 will
      remove PE1 from its outgoing path list for traffic originating
      from CE4.

5.3.  PE Port Failure

   In the event of a PE port failure, the failure will be signaled, and
   the other PE will assume forwarding in both scenarios:

   *  Default FXC (Figure 1): In the case of a port failure, such as p2,
      the route for Service Tunnel 2 (sv.T2) will be withdrawn.  Upon
      receiving the fault notification, PE3 will remove PE1 from its
      path list for traffic originating from CE4 and CE5.

   *  VLAN-Signaled FXC (Figure 2): A port failure, such as p2, triggers
      the withdrawal of the Ethernet A-D per EVI routes for Normalized
      VIDs 2 and 3, along with the withdrawal of the Ethernet A-D per ES
      route for p2's ES.  Upon receiving the fault notification, PE3
      will remove PE1 from its path list for the traffic originating
      from CE4 and CE5.

5.4.  PE Node Failure

   In the case of PE node failure, the operation is similar to the steps
   described above, albeit that EVPN route withdrawals are performed by
   the Route Reflector instead of the PE.

6.  Security Considerations

   Since this document describes a muxing capability which leverages
   EVPN-VPWS signaling, no additional functionality beyond the muxing
   service is added and thus no additional security considerations are
   needed beyond what is already specified in [RFC8214].

Sajassi, et al.           Expires 23 March 2025                [Page 15]
Internet-Draft      EVPN VPWS Flexible Cross-Connect      September 2024

7.  IANA Considerations

   This document requests allocation of bits 8-11 in the "EVPN Layer 2
   Attributes Control Flags" registry with names M and V:

      M     Signaling mode of operation (2 bits)
      V     VLAN-ID normalization (2 bits)

8.  References

8.1.  Normative References

   [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
              Requirement Levels", BCP 14, RFC 2119,
              DOI 10.17487/RFC2119, March 1997,
              <https://www.rfc-editor.org/info/rfc2119>.

   [RFC7432]  Sajassi, A., Ed., Aggarwal, R., Bitar, N., Isaac, A.,
              Uttaro, J., Drake, J., and W. Henderickx, "BGP MPLS-Based
              Ethernet VPN", RFC 7432, DOI 10.17487/RFC7432, February
              2015, <https://www.rfc-editor.org/info/rfc7432>.

   [RFC8174]  Leiba, B., "Ambiguity of Uppercase vs Lowercase in RFC
              2119 Key Words", BCP 14, RFC 8174, DOI 10.17487/RFC8174,
              May 2017, <https://www.rfc-editor.org/info/rfc8174>.

   [RFC8214]  Boutros, S., Sajassi, A., Salam, S., Drake, J., and J.
              Rabadan, "Virtual Private Wire Service Support in Ethernet
              VPN", RFC 8214, DOI 10.17487/RFC8214, August 2017,
              <https://www.rfc-editor.org/info/rfc8214>.

8.2.  Informative References

   [I-D.ietf-rtgwg-bgp-pic]
              Bashandy, A., Filsfils, C., and P. Mohapatra, "BGP Prefix
              Independent Convergence", Work in Progress, Internet-
              Draft, draft-ietf-rtgwg-bgp-pic-21, 7 July 2024,
              <https://datatracker.ietf.org/doc/html/draft-ietf-rtgwg-
              bgp-pic-21>.

   [RFC5659]  Bocci, M. and S. Bryant, "An Architecture for Multi-
              Segment Pseudowire Emulation Edge-to-Edge", RFC 5659,
              DOI 10.17487/RFC5659, October 2009,
              <https://www.rfc-editor.org/info/rfc5659>.

Sajassi, et al.           Expires 23 March 2025                [Page 16]
Internet-Draft      EVPN VPWS Flexible Cross-Connect      September 2024

   [RFC8365]  Sajassi, A., Ed., Drake, J., Ed., Bitar, N., Shekhar, R.,
              Uttaro, J., and W. Henderickx, "A Network Virtualization
              Overlay Solution Using Ethernet VPN (EVPN)", RFC 8365,
              DOI 10.17487/RFC8365, March 2018,
              <https://www.rfc-editor.org/info/rfc8365>.

Appendix A.  Contributors

   In addition to the authors listed on the front page, the following
   co-authors have also contributed substantially to this document:

   Wen Lin
   Juniper Networks

   EMail: wlin@juniper.net

   Luc Andre Burdet
   Cisco

   EMail: lburdet@cisco.com

Authors' Addresses

   Ali Sajassi (editor)
   Cisco Systems
   Email: sajassi@cisco.com

   Patrice Brissette
   Cisco Systems
   Email: pbrisset@cisco.com

   James Uttaro
   AT&T
   Email: uttaro@att.com

   John Drake
   Juniper Networks
   Email: jdrake@juniper.net

   Sami Boutros
   Ciena
   Email: sboutros@ciena.com

Sajassi, et al.           Expires 23 March 2025                [Page 17]
Internet-Draft      EVPN VPWS Flexible Cross-Connect      September 2024

   Jorge Rabadan
   Nokia
   Email: jorge.rabadan@nokia.com

Sajassi, et al.           Expires 23 March 2025                [Page 18]