Skip to main content

Forwarding and Control Element Separation (ForCES) Framework
draft-ietf-forces-framework-13

The information below is for an old version of the document that is already published as an RFC.
Document Type
This is an older version of an Internet-Draft that was ultimately published as RFC 3746.
Authors Lily Yang , Todd A. Anderson , Ram Gopal , Ram Dantu
Last updated 2018-05-01 (Latest revision 2004-01-15)
RFC stream Internet Engineering Task Force (IETF)
Intended RFC status Informational
Formats
Additional resources Mailing list discussion
Stream WG state WG Document
Document shepherd (None)
IESG IESG state Became RFC 3746 (Informational)
Action Holders
(None)
Consensus boilerplate Unknown
Telechat date (None)
Responsible AD Alex D. Zinin
Send notices to <dro@zurich.ibm.com>, <David.Putzolu@intel.com>
draft-ietf-forces-framework-13
Internet Draft                                              L. Yang 
    Expiration: July 2004                                   Intel Corp. 
    File: draft-ietf-forces-framework-13.txt                   R. Dantu 
    Working Group: ForCES                          Univ. of North Texas 
                                                            T. Anderson 
                                                            Intel Corp. 
                                                               R. Gopal 
                                                                  Nokia 
     
                                                         January 2004 
  
        Forwarding and Control Element Separation (ForCES) Framework 
     
     
     
                    draft-ietf-forces-framework-13.txt 
     
     
     
     
 Status of this Memo 
     
    This document is an Internet-Draft and is in full conformance with 
    all provisions of Section 10 of RFC2026.  Internet-Drafts are 
    working documents of the Internet Engineering Task Force (IETF), 
    its areas, and its working groups.  Note that other groups may also 
    distribute working documents as Internet-Drafts. 
     
    Internet-Drafts are draft documents valid for a maximum of six 
    months and may be updated, replaced, or obsoleted by other 
    documents at any time.  It is inappropriate to use Internet-Drafts 
    as reference material or to cite them other than as ``work in 
    progress.'' 
     
    The list of current Internet-Drafts can be accessed at 
    http://www.ietf.org/ietf/1id-abstracts.txt. 
     
    The list of Internet-Draft Shadow Directories can be accessed at  
    http://www.ietf.org/shadow.html. 
     
 Copyright Notice  
     
    Copyright (C) The Internet Society (2003).  All Rights Reserved. 
     
 Abstract 
  
    This document defines the architectural framework for the ForCES 
    (Forwarding and Control Element Separation) network elements, and 
    identifies the associated entities and the interactions among them. 
     
 Table of Contents 
  
  

 Internet Draft         ForCES Framework                 January 2004 
  
  
     
    1. Definitions...................................................3 
       1.1. Conventions used in this document........................3 
       1.2. Terminologies............................................3 
    2. Introduction to Forwarding and Control Element Separation 
    (ForCES).........................................................5 
    3. Architecture..................................................9 
       3.1. Control Elements and Fr Reference Point.................10 
       3.2. Forwarding Elements and Fi reference point..............11 
       3.3. CE Managers.............................................15 
       3.4. FE Managers.............................................15 
    4. Operational Phases...........................................15 
       4.1. Pre-association Phase...................................15 
          4.1.1. Fl Reference Point.................................15 
          4.1.2. Ff Reference Point.................................16 
          4.1.3. Fc Reference Point.................................17 
       4.2. Post-association Phase and Fp reference point...........17 
          4.2.1. Proximity and Interconnect between CEs and FEs.....18 
          4.2.2. Association Establishment..........................18 
          4.2.3. Steady-state Communication.........................20 
          4.2.4. Data Packets across Fp reference point.............20 
          4.2.5. Proxy FE...........................................22 
       4.3. Association Re-establishment............................22 
          4.3.1. CE graceful restart................................22 
          4.3.2. FE restart.........................................24 
    5. Applicability to RFC1812.....................................25 
       5.1. General Router Requirements.............................25 
       5.2. Link Layer..............................................26 
       5.3. Internet Layer Protocols................................27 
       5.4. Internet Layer Forwarding...............................28 
       5.5. Transport Layer.........................................29 
       5.6. Application Layer -- Routing Protocols..................29 
       5.7. Application Layer -- Network Management Protocol........29 
    6. Summary......................................................30 
    7. Acknowledgements.............................................30 
    8. Security Considerations......................................30 
       8.1. Analysis of Potential Threats Introduced by ForCES......31 
          8.1.1. "Join" or "Remove" Message Flooding on CEs.........31 
          8.1.2. Impersonation Attack...............................32 
          8.1.3. Replay Attack......................................32 
          8.1.4. Attack during Fail Over............................32 
          8.1.5. Data Integrity.....................................32 
          8.1.6. Data Confidentiality...............................33 
          8.1.7. Sharing security parameters........................33 
          8.1.8. Denial of Service Attack via External Interface....33 
       8.2. Security Recommendations for ForCES.....................34 
          8.2.1. Using TLS with ForCES..............................34 
  
  
 Yang, et al.      Expires July    2004                   [Page 2]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
          8.2.2. Using IPsec with ForCES............................35 
    9. Normative References.........................................37 
    10. Informative References......................................37 
    11. Authors' Addresses..........................................38 
    12. Intellectual Property Right.................................39 
    13. Full Copyright Statement....................................39 
     
     
 1. Definitions 
   
 1.1. Conventions used in this document  
         
    The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", 
    "SHOULD", "SHOULD NOT", "RECOMMENDED",  "MAY", and "OPTIONAL" in 
    this document are to be interpreted as described in RFC 2119. 
  
 1.2. Terminologies 
     
    A set of terminology associated with the ForCES requirements is 
    defined in [3] and we only include the definitions that are most 
    relevant to this document here.  
     
    Addressable Entity (AE) - An entity that is directly addressable 
    given some interconnect technology.  For example, on IP networks, 
    it is a device to which we can communicate using an IP address; on 
    a switch fabric, it is a device to which we can communicate using a 
    switch fabric port number.  
     
    Physical Forwarding Element (PFE) - An AE that includes hardware 
    used to provide per-packet processing and handling.  This hardware 
    may consist of (but is not limited to) network processors, ASICs 
    (Application-Specific Integrated Circuits), or general purpose 
    processors, installed on line cards, daughter boards, mezzanine 
    cards, or in stand-alone boxes. 
         
    PFE Partition - A logical partition of a PFE consisting of some 
    subset of each of the resources (e.g., ports, memory, forwarding 
    table entries) available on the PFE.  This concept is analogous to 
    that of the resources assigned to a virtual switching element as 
    described in [8].  
         
    Physical Control Element (PCE) - An AE that includes hardware used 
    to provide control functionality.  This hardware typically includes 
    a general purpose processor.  
         
    PCE Partition - A logical partition of a PCE consisting of some 
    subset of each of the resources available on the PCE.  
  
  
 Yang, et al.      Expires July    2004                   [Page 3]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
         
    Forwarding Element (FE) - A logical entity that implements the 
    ForCES Protocol.  FEs use the underlying hardware to provide per-
    packet processing and handling as directed by a CE via the ForCES 
    Protocol.  FEs may happen to be a single blade (or PFE), a 
    partition of a PFE or multiple PFEs. 
     
    Control Element (CE) - A logical entity that implements the ForCES 
    Protocol and uses it to instruct one or more FEs how to process 
    packets.  CEs handle functionality such as the execution of control 
    and signaling protocols.  CEs may consist of PCE partitions or 
    whole PCEs. 
         
    ForCES Network Element (NE) - An entity composed of one or more CEs 
    and one or more FEs.  To entities outside an NE, the NE represents 
    a single point of management.  Similarly, an NE usually hides its 
    internal organization from external entities.  
         
    Pre-association Phase - The period of time during which an FE 
    Manager (see below) and a CE Manager (see below) are determining 
    whether an FE and a CE should be part of the same network element.  
    It is possible for some elements of the NE to be in pre-association 
    phase while other elements are in the post-association phase. 
     
    Post-association Phase - The period of time during which an FE does 
    know which CE is to control it and vice versa, including the time 
    during which the CE and FE are establishing communication with one 
    another.  
         
    ForCES Protocol - While there may be multiple protocols used within 
    the overall ForCES architecture, the term "ForCES Protocol" refers 
    only to the ForCES post-association phase protocol (see below).  
         
    ForCES Post-Association Phase Protocol - The protocol used for 
    post-association phase communication between CEs and FEs.  This 
    protocol does not apply to CE-to-CE communication, FE-to-FE 
    communication, nor to communication between FE and CE managers.  
    The ForCES Protocol is a master-slave protocol in which FEs are 
    slaves and CEs are masters.   This protocol includes both the 
    management of the communication channel (e.g., connection 
    establishment, heartbeats) and the control messages themselves.  
    This protocol could be a single protocol or could consist of 
    multiple protocols working together, and may be unicast based or 
    multicast based. A separate protocol document will specify this 
    information. 
         
  
  
 Yang, et al.      Expires July    2004                   [Page 4]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    FE Manager - A logical entity that operates in the pre-association 
    phase and is responsible for determining to which CE(s) an FE 
    should communicate.  This process is called CE discovery and may 
    involve the FE manager learning the capabilities of available CEs.  
    An FE manager may use anything from a static configuration to a 
    pre-association phase protocol (see below) to determine which CE(s) 
    to use; however, this is currently out of scope.  Being a logical 
    entity, an FE manager might be physically combined with any of the 
    other logical entities mentioned in this section.  
         
    CE Manager - A logical entity that operates in the pre-association  
    phase and is responsible for determining to which FE(s) a CE should 
    communicate.  This process is called FE discovery and may involve 
    the CE manager learning the capabilities of available FEs.  A CE 
    manager may use anything from a static configuration to a pre-
    association phase protocol (see below) to determine which FE to 
    use, however this is currently out of scope.   Being a logical 
    entity, a CE manager might be physically combined with any of the 
    other logical entities mentioned in this section.  
         
    Pre-association Phase Protocol - A protocol between FE managers and 
    CE managers that is used to determine which CEs or FEs to use.  A 
    pre-association phase protocol may include a CE and/or FE 
    capability discovery mechanism.  Note that this capability 
    discovery process is wholly separate from (and does not replace) 
    that used within the ForCES Protocol.  However, the two capability 
    discovery mechanisms may utilize the same FE model.   
         
    FE Model - A model that describes the logical processing functions 
    of an FE.  
         
    ForCES Protocol Element - An FE or CE.  
     
    Intra-FE topology - Representation of how a single FE is realized 
    by combining possibly multiple logical functional blocks along 
    multiple data path. This is defined by the FE model.  
  
    FE Topology - Representation of how the multiple FEs in a single NE 
    are interconnected.  Sometimes it is called inter-FE topology, to 
    be distinguished from intra-FE topology used by the FE model. 
     
    Inter-FE topology - see FE Topology. 
     
 2. Introduction to Forwarding and Control Element Separation (ForCES)  
  
    An IP network element (NE) appears to external entities as a 
    monolithic piece of network equipment, e.g., a router, NAT, 
    firewall, or load balancer.  Internally, however, an IP network 
  
  
 Yang, et al.      Expires July    2004                   [Page 5]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    element (NE) (such as a router) is composed of numerous logically 
    separated entities that cooperate to provide a given functionality 
    (such as routing).  Two types of network element components exist: 
    control element (CE) in control plane and forwarding element (FE) 
    in forwarding plane (or data plane).  Forwarding elements typically 
    are ASIC, network-processor, or general-purpose processor-based 
    devices that handle data path operations for each packet.  Control 
    elements are typically based on general-purpose processors that 
    provide control functionality like routing and signaling protocols. 
     
    ForCES aims to define a framework and associated protocol(s) to 
    standardize information exchange between the control and forwarding 
    plane.  Having standard mechanisms allows CEs and FEs to become 
    physically separated standard components.  This physical separation 
    accrues several benefits to the ForCES architecture.  Separate 
    components would allow component vendors to specialize in one 
    component without having to become experts in all components. 
    Standard protocol also allows the CEs and FEs from different 
    component vendors to interoperate with each other and hence it 
    becomes possible for system vendors to integrate together the CEs 
    and FEs from different component suppliers.  This interoperability 
    translates into more design choices and flexibility for the system 
    vendors.  Overall, ForCES will enable rapid innovation in both the 
    control and forwarding planes while maintaining interoperability.  
    Scalability is also easily provided by this architecture in that 
    additional forwarding or control capacity can be added to existing 
    network elements without the need for forklift upgrades. 
     
         -------------------------       ------------------------- 
         |  Control Blade A      |       |  Control Blade B      | 
         |       (CE)            |       |          (CE)         | 
         -------------------------       ------------------------- 
                 ^   |                           ^    | 
                 |   |                           |    | 
                 |   V                           |    V 
         --------------------------------------------------------- 
         |               Switch Fabric Backplane                 | 
         --------------------------------------------------------- 
                ^  |            ^  |                   ^  |         
                |  |            |  |     . . .         |  |         
                |  V            |  V                   |  V         
            ------------    ------------           ------------     
            |Router    |    |Router    |           |Router    | 
            |Blade #1  |    |Blade #2  |           |Blade #N  | 
            |   (FE)   |    |   (FE)   |           |   (FE)   | 
            ------------    ------------           ------------     
                ^  |            ^  |                   ^  |         
  
  
 Yang, et al.      Expires July    2004                   [Page 6]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
                |  |            |  |     . . .         |  |         
                |  V            |  V                   |  V         
          
         Figure 1. A router configuration example with separate blades. 
  
    One example of such physical separation is at the blade level. 
    Figure 1 shows such an example configuration of a router, with two 
    control blades and multiple forwarding blades, all interconnected 
    into a switch fabric backplane.  In such a chassis configuration, 
    the control blades are the CEs while the router blades are FEs, and 
    the switch fabric backplane provides the physical interconnect for 
    all the blades.  Control blade A may be the primary CE while 
    control blade B may be the backup CE providing redundancy.  It is 
    also possible to have a redundant switch fabric for high 
    availability support.  Routers today with this kind of 
    configuration use proprietary interfaces for messaging between CEs 
    and FEs.  The goal of ForCES is to replace such proprietary 
    interfaces with a standard protocol.  With a standard protocol like 
    ForCES implemented on all blades, it becomes possible for control 
    blades from vendor X and forwarding blades from vendor Y to work 
    seamlessly together in one chassis.  
  
  
         -------         ------- 
         | CE1 |         | CE2 | 
         -------         ------- 
            ^               ^ 
            |               | 
            V               V 
     ============================================ Ethernet 
         ^       ^       . . .   ^ 
         |       |               | 
         V       V               V 
      -------  -------         -------- 
      | FE#1|  | FE#2|         | FE#n | 
      -------  -------         -------- 
        ^  |     ^  |            ^  |         
        |  |     |  |            |  |         
        |  V     |  V            |  V         
          
         Figure 2. A router configuration example with separate boxes. 
     
    Another level of physical separation between the CEs and FEs can be 
    at the box level.  In such configuration, all the CEs and FEs are 
    physically separated boxes, interconnected with some kind of high 
    speed LAN connection (like Gigabit Ethernet).  These separated CEs 
    and FEs are only one hop away from each other within a local area 
  
  
 Yang, et al.      Expires July    2004                   [Page 7]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    network.  The CEs and FEs communicate to each other by running 
    ForCES, and the collection of these CEs and FEs together become one 
    routing unit to the external world. Figure 2 shows such an example. 
     
    In both examples shown here, the same physical interconnect is used 
    for both CE-to-FE and FE-to-FE communication.  However, that does 
    not have to be the case.  One reason to use different interconnects 
    is that CE-to-FE interconnect does not have to be as fast as the 
    FE-to-FE interconnect, so the more expensive fast connections can 
    be saved for FE-to-FE.  The separate interconnects may also provide 
    reliability and redundancy benefits for the NE. 
  
    Some examples of control functions that can be implemented in the 
    CE include routing protocols like RIP, OSPF and BGP, control and 
    signaling protocols like RSVP (Resource Reservation Protocol), LDP 
    (Label Distribution Protocol) for MPLS, etc.  Examples of 
    forwarding functions in the FE include LPM (longest prefix match) 
    forwarder, classifiers, traffic shaper, meter, NAT (Network Address 
    Translators), etc.  Figure 3 provides example functions in both CE 
    and FE.  Any given NE may contain one or many of these CE and FE 
    functions in it.  The diagram also shows that ForCES Protocol is 
    used to transport both the control messages for ForCES itself and 
    the data packets that are originated/destined from/to the control 
    functions in CE (e.g., routing packets).  Section 4.2.4 provides 
    more detail on this.  
     
         ------------------------------------------------- 
         |       |       |       |       |       |       | 
         |OSPF   |RIP    |BGP    |RSVP   |LDP    |. . .  | 
         |       |       |       |       |       |       | 
         ------------------------------------------------- 
         |               ForCES Interface                | 
         ------------------------------------------------- 
                                 ^   ^                    
                         ForCES  |   |data        
                         control |   |packets     
                         messages|   |(e.g., routing packets) 
                                 v   v 
         ------------------------------------------------- 
         |               ForCES Interface                | 
         ------------------------------------------------- 
         |       |       |       |       |       |       | 
         |LPM Fwd|Meter  |Shaper |NAT    |Classi-|. . .  | 
         |       |       |       |       |fier   |       | 
         ------------------------------------------------- 
         |               FE resources                    | 
         ------------------------------------------------- 
  
  
 Yang, et al.      Expires July    2004                   [Page 8]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
     
                 Figure 3. Examples of CE and FE functions 
     
     
    A set of requirements for control and forwarding separation is 
    identified in [3].  This document describes a ForCES architecture 
    that satisfies the architectural requirements of that document and 
    defines a framework for ForCES network elements and the associated 
    entities to facilitate protocol definition.  Whenever necessary, 
    this document uses many examples to illustrate the issues and/or 
    possible solutions in ForCES.  These examples are intended to be 
    just examples, and should not be taken as the only or definite ways 
    of doing certain things.  It is expected that separate document 
    will be produced by the ForCES working group to specify the ForCES 
    Protocol. 
     
 3. Architecture 
  
    This section defines the ForCES architectural framework and the 
    associated logical components.  This ForCES framework defines 
    components of ForCES NEs including several ancillary components.  
    These components may be connected in different kinds of topologies 
    for flexible packet processing.  
     
                            --------------------------------------- 
                            | ForCES Network Element              | 
     --------------   Fc    | --------------      --------------  | 
     | CE Manager |---------+-|     CE 1   |------|    CE 2    |  | 
     --------------         | |            |  Fr  |            |  | 
           |                | --------------      --------------  | 
           | Fl             |         |  |    Fp       /          | 
           |                |       Fp|  |----------| /           | 
           |                |         |             |/            | 
           |                |         |             |             | 
           |                |         |     Fp     /|----|        | 
           |                |         |  /--------/      |        | 
     --------------     Ff  | --------------      --------------  | 
     | FE Manager |---------+-|     FE 1   |  Fi  |     FE 2   |  | 
     --------------         | |            |------|            |  | 
                            | --------------      --------------  |
                            |   |  |  |  |          |  |  |  |    | 
                            ----+--+--+--+----------+--+--+--+----- 
                                |  |  |  |          |  |  |  | 
                                |  |  |  |          |  |  |  | 
                                  Fi/f                   Fi/f 
     
         Fp: CE-FE interface  
  
  
 Yang, et al.      Expires July    2004                   [Page 9]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
         Fi: FE-FE interface 
         Fr: CE-CE interface 
         Fc: Interface between the CE Manager and a CE 
         Ff: Interface between the FE Manager and an FE 
         Fl: Interface between the CE Manager and the FE Manager 
         Fi/f: FE external interface  
     
                 Figure 4. ForCES Architectural Diagram 
     
    The diagram in Figure 4 shows the logical components of the ForCES 
    architecture and their relationships.  There are two kinds of 
    components inside a ForCES network element: control element (CE) 
    and forwarding element (FE).  The framework allows multiple 
    instances of CE and FE inside one NE.  Each FE contains one or more 
    physical media interfaces for receiving and transmitting packets 
    from/to the external world.  The aggregation of these FE interfaces 
    becomes the NE's external interfaces.  In addition to the external 
    interfaces, there must also exist some kind of interconnect within 
    the NE so that the CE and FE can communicate with each other, and 
    one FE can forward packets to another FE.  The diagram also shows 
    two entities outside of the ForCES NE: CE Manager and FE Manager.  
    These two ancillary entities provide configuration to the 
    corresponding CE or FE in the pre-association phase (see Section 
    4.1).   
     
    For convenience, the logical interactions between these components 
    are labeled by reference points Fp, Fc, Ff, Fr, Fl, and Fi, as 
    shown in Figure 4.  The FE external interfaces are labeled as Fi/f. 
    More detail is provided in Section 3 and 4 for each of these 
    reference points.  All these reference points are important in 
    understanding the ForCES architecture, however, the ForCES Protocol 
    is only defined over one reference point -- Fp.  
     
    The interface between two ForCES NEs is identical to the interface 
    between two conventional routers and these two NEs exchange the 
    protocol packets through the external interfaces at Fi/f.  ForCES 
    NEs connect to existing routers transparently. 
  
 3.1. Control Elements and Fr Reference Point 
     
    It is not necessary to define any protocols across the Fr reference 
    point to enable control and forwarding separation for simple 
    configurations like single CE and multiple FEs.  However, this 
    architecture permits multiple CEs to be present in a network 
    element.  In cases where an implementation uses multiple CEs, the 
    invariant that the CEs and FEs together appear as a single NE must 
    be maintained. 
  
  
 Yang, et al.      Expires July    2004                   [Page 10]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
     
    Multiple CEs may be used for redundancy, load sharing, distributed 
    control, or other purposes.  Redundancy is the case where one or 
    more CEs are prepared to take over should an active CE fail.  Load 
    sharing is the case where two or more CEs are concurrently active 
    and any request that can be serviced by one of the CEs can also be 
    serviced by any of the other CEs.  For both redundancy and load 
    sharing, the CEs involved are equivalently capable.  The only 
    difference between these two cases is in terms of how many active 
    CEs there are.  Distributed control is the case where two or more 
    CEs are concurrently active but certain requests can only be 
    serviced by certain CEs. 
  
    When multiple CEs are employed in a ForCES NE, their internal 
    organization is considered an implementation issue that is beyond 
    the scope of ForCES.  CEs are wholly responsible for coordinating 
    amongst themselves via the Fr reference point to provide 
    consistency and synchronization.  However, ForCES does not define 
    the implementation or protocols used between CEs, nor does it 
    define how to distribute functionality among CEs.  Nevertheless, 
    ForCES will support mechanisms for CE redundancy or fail over, and 
    it is expected that vendors will provide redundancy or fail over 
    solutions within this framework. 
  
  
 3.2. Forwarding Elements and Fi reference point 
     
    An FE is a logical entity that implements the ForCES Protocol and 
    uses the underlying hardware to provide per-packet processing and 
    handling as directed by a CE.  It is possible to partition one 
    physical FE into multiple logical FEs.  It is also possible for one 
    FE to use multiple physical FEs.  The mapping between physical 
    FE(s) and the logical FE(s) is beyond the scope of ForCES.  For 
    example, a logical partition of a physical FE can be created by 
    assigning some portion of each of the resources (e.g., ports, 
    memory, forwarding table entries) available on the ForCES physical 
    FE to each of the logical FEs.  Such concept of FE virtualization 
    is analogous to a virtual switching element as described in [8].  
    If FE virtualization occurs only in the pre-association phase, it 
    has no impact on ForCES. However, if FE virtualization results in 
    resource change taken from an existing FE (already participating in 
    ForCES post-association phase), the ForCES Protocol needs to be 
    able to inform the CE of such change via asynchronous messages (see 
    [3], Section 5, requirement #6). 
     
    FEs perform all packet processing functions as directed by CEs.  
  
  
 Yang, et al.      Expires July    2004                   [Page 11]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    FEs have no initiative of their own.  Instead, FEs are slaves and 
    only do as they are told.  FEs may communicate with one or more CEs 
    concurrently across reference point Fp.  FEs have no notion of CE 
    redundancy, load sharing, or distributed control.  Instead, FEs 
    accept commands from any CE authorized to control them, and it is 
    up to the CEs to coordinate among themselves to achieve redundancy, 
    load sharing or distributed control.  The idea is to keep FEs as 
    simple and dumb as possible so that FEs can focus their resource on 
    the packet processing functions.  Unless otherwise configured or 
    determined by a ForCEs Protocol exchange, each FE will process 
    authorized incoming commands directed at it as it receives them on 
    a first come first serve basis.   
     
    For example, in Figure 5, FE1 and FE2 can be configured to accept 
    commands from both the primary CE (CE1) and the backup CE (CE2).  
    Upon detection of CE1 failure, perhaps across the Fr or Fp 
    reference point, CE2 is configured to take over activities of CE1.  
    This is beyond the scope of ForCES and is not discussed further. 
     
    Distributed control can be achieved in a similar fashion, without 
    much intelligence on the part of FEs.  For example, FEs can be 
    configured to detect RSVP and BGP protocol packets, and forward 
    RSVP packets to one CE and BGP packets to another CE.  Hence, FEs 
    may need to do packet filtering for forwarding packets to specific 
    CEs. 
     
                 -------   Fr  ------- 
                 | CE1 | ------| CE2 | 
                 -------       ------- 
                   |   \      /   | 
                   |    \    /    | 
                   |     \  /     | 
                   |      \/Fp    | 
                   |      /\      | 
                   |     /  \     | 
                   |    /    \    | 
                 -------  Fi   ------- 
                 | FE1 |<----->| FE2 | 
                 -------       ------- 
  
                    Figure 5. CE redundancy example. 
     
    This architecture permits multiple FEs to be present in an NE. [3] 
    dictates that the ForCES Protocol must be able to scale to at least 
    hundreds of FEs (see [3] Section 5, requirement #11).  Each of 
    these FEs may potentially have a different set of packet processing 
    functions, with different media interfaces.  FEs are responsible 
  
  
 Yang, et al.      Expires July    2004                   [Page 12]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    for basic maintenance of layer-2 connectivity with other FEs and 
    with external entities.  Many layer-2 media include sophisticated 
    control protocols.  The FORCES Protocol (over the Fp reference 
    point) will be able to carry messages for such protocols so that, 
    in keeping with the dumb FE model, the CE can provide appropriate 
    intelligence and control over these media. 
     
    When multiple FEs are present, ForCES requires that packets must be 
    able to arrive at the NE by one FE and leave the NE via a different 
    FE (See [3], Section 5, Requirement #3).  Packets that enter the NE 
    via one FE and leave the NE via a different FE are transferred 
    between FEs across the Fi reference point.  Fi reference point 
    could be used by FEs to discovery their (inter-FE) topology, 
    perhaps during pre-association phase.  The Fi reference point is a 
    separate protocol from the Fp reference point and is not currently 
    defined by the ForCES architecture. 
     
    FEs could be connected in different kinds of topologies and packet 
    processing may spread across several FEs in the topology.  Hence, 
    logical packet flow may be different from physical FE topology. 
    Figure 6 provides some topology examples.  When it is necessary to 
    forward packets between FEs, the CE needs to understand the FE 
    topology.  The FE topology may be queried from the FEs by the CEs 
    via ForCES Protocol, but the FEs are not required to provide that 
    information to the CEs. So, the FE topology information may also be 
    gathered by other means outside of the ForCES Protocol (like inter-
    FE topology discovery protocol).  
                  
                         -----------------               
                         |      CE       |         
                         -----------------         
                          ^      ^      ^ 
                         /       |       \ 
                        /        v        \ 
                       /      -------      \ 
                      /    +->| FE3 |<-+    \ 
                     /     |  |     |  |     \ 
                    v      |  -------  |      v 
                  -------  |           |  ------- 
                  | FE1 |<-+           +->| FE2 | 
                  |     |<--------------->|     | 
                  -------                 ------- 
                     ^  |                   ^  | 
                     |  |                   |  | 
                     |  v                   |  v 
     
                 (a) Full mesh among FE1, FE2 and FE3. 
  
  
 Yang, et al.      Expires July    2004                   [Page 13]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
  
     
                         -----------             
                         |   CE    |       
                         -----------         
                        ^ ^       ^ ^ 
                       /  |       |  \ 
                /------   |       |   ------\ 
                v         v       v          v 
            -------   -------   -------   ------- 
            | FE1 |<->| FE2 |<->| FE3 |<->| FE4 | 
            -------   -------   -------   ------- 
              ^  |     ^  |       ^  |     ^  | 
              |  |     |  |       |  |     |  | 
              |  v     |  v       |  v     |  v 
     
                 (b) Multiple FEs in a daisy chain 
  
  
  
                            ^ | 
                            | v 
                         -----------             
                         |   FE1   |<-----------------------|      
                         -----------                        | 
                           ^    ^                           | 
                          /      \                          |  
                   | ^   /        \   ^ |                   V 
                   v |  v          v  | v                ---------- 
                 ---------        ---------              |        | 
                 | FE2   |        |  FE3  |<------------>|   CE   | 
                 ---------        ---------              |        | 
                     ^  ^          ^                     ---------- 
                     |   \        /                        ^  ^ 
                     |    \      /                         |  | 
                     |    v     v                          |  | 
                     |   -----------                       |  | 
                     |   |   FE4   |<----------------------|  |    
                     |   -----------                          | 
                     |      |  ^                              | 
                     |      v  |                              | 
                     |                                        | 
                     |----------------------------------------| 
     
                 (c) Multiple FEs connected by a ring 
     
                 Figure 6. Some examples of FE topology. 
  
  
 Yang, et al.      Expires July    2004                   [Page 14]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
     
 3.3.CE Managers 
     
    CE managers are responsible for determining which FEs a CE should 
    control.  It is legitimate for CE managers to be hard-coded with 
    the knowledge of with which FEs its CEs should communicate with.  A 
    CE manager may also be physically embedded into a CE and be 
    implemented as a simple keypad or other direct configuration 
    mechanism on the CE.  Finally, CE managers may be physically and 
    logically separate entities that configure the CE with FE 
    information via such mechanisms as COPS-PR [6] or SNMP [4]. 
     
 3.4. FE Managers 
     
    FE managers are responsible for determining with which CE any 
    particular FE should initially communicate.  Like CE managers, no 
    restrictions are placed on how an FE manager decides with which CE 
    its FEs should communicate, nor are restrictions placed on how FE 
    managers are implemented.  Each FE should have one and only one FE 
    manager, while different FEs may have the same or different FE 
    manager(s).  Each manager can choose to exist and operate 
    independently of other manager. 
  
 4. Operational Phases 
     
    Both FEs and CEs require some configuration in place before they 
    can start information exchange and function as a coherent network 
    element.  Two operational phases are identified in this framework: 
    pre-association and post-association.  
     
 4.1.Pre-association Phase 
  
    Pre-association phase is the period of time during which an FE 
    Manager and a CE Manager are determining whether an FE and a CE 
    should be part of the same network element.  The protocols used 
    during this phase may include all or some of the message exchange 
    over Fl, Ff and Fc reference points.  However, all these may be 
    optional and none of this is within the scope of ForCES Protocol. 
     
 4.1.1. Fl Reference Point 
  
    CE managers and FE managers may communicate across the Fl reference 
    point in the pre-association phase in order to determine whether an 
    individual CE and FE, or a set of CEs and FEs should be associated. 
    Communication across the Fl reference point is optional in this 
    architecture.  No requirements are placed on this reference point. 
  
  
  
 Yang, et al.      Expires July    2004                   [Page 15]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    CE managers and FE managers may be operated by different entities.  
    The operator of the CE manager may not want to divulge, except to 
    specified FE managers, any characteristics of the CEs it manages.   
    Similarly, the operator of the FE manager may not want to divulge 
    FE characteristics, except to authorized entities.  As such, CE 
    managers and FE managers may need to authenticate one another.   
    Subsequent communication between CE managers and FE managers may 
    require other security functions such as privacy, non-repudiation, 
    freshness, and integrity. 
     
         FE Manager      FE               CE Manager     CE 
          |              |                 |             | 
          |              |                 |             | 
          |(security exchange)             |             | 
         1|<------------------------------>|             | 
          |              |                 |             | 
          |(a list of CEs and their attributes)          | 
         2|<-------------------------------|             | 
          |              |                 |             | 
          |(a list of FEs and their attributes)          | 
         3|------------------------------->|             | 
          |              |                 |             | 
          |              |                 |             | 
          |<----------------Fl------------>|             | 
     
      Figure 7. An example of message exchange over Fl reference point 
     
    Once the necessary security functions have been performed, the CE 
    and FE managers communicate to determine which CEs and FEs should 
    communicate with each other.  At the very minimum, the CE and FE 
    managers need to learn of the existence of available FEs and CEs 
    respectively.  This discovery process may entail one or both 
    managers learning the capabilities of the discovered ForCES 
    protocol elements.  Figure 7 shows an example of possible message 
    exchange between CE manager and FE manager over Fl reference point. 
     
 4.1.2. Ff Reference Point 
     
    The Ff reference point is used to inform forwarding elements of the 
    association decisions made by the FE manager in pre-association 
    phase.  Only authorized entities may instruct an FE with respect to 
    which CE should control it.  Therefore, privacy, integrity, 
    freshness, and authentication are necessary between the FE manager 
    and FEs when the FE manager is remote to the FE.  Once the 
    appropriate security has been established, the FE manager instructs 
    the FEs across this reference point to join a new NE or to 
  
  
 Yang, et al.      Expires July    2004                   [Page 16]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    disconnect from an existing NE. The FE Manager could also assign 
    unique FE identifiers to the FEs using this reference point.  The 
    FE identifiers are useful in post association phase to express FE 
    topology.  Figure 8 shows example of message exchange over Ff 
    reference point. 
  
         FE Manager      FE               CE Manager     CE 
          |              |                |             | 
          |              |                |             | 
          |(security exchange)            |(security exchange) 
         1|<------------>|authentication 1|<----------->|authentication
          |              |                |             | 
          |(FE ID, attributes)            |(CE ID, attributes) 
         2|<-------------|request        2|<----------->|request 
          |              |                |             | 
         3|------------->|response       3|------------>|response 
          |(corresponding CE ID)          |(corresponding FE ID) 
          |              |                |             | 
          |              |                |             | 
          |<-----Ff----->|                |<-----Fc---->| 
     
                     Figure 8. Examples of message exchange 
                        over Ff and Fc reference points. 
                                         
    Note that the FE manager function may be co-located with the FE 
    (such as by manual keypad entry of the CE IP address), in which 
    case this reference point is reduced to a built-in function. 
                                         
     
 4.1.3. Fc Reference Point 
     
    The Fc reference point is used to inform control elements of the 
    association decisions made by CE managers in pre-association phase. 
    When the CE manager is remote, only authorized entities may 
    instruct a CE to control certain FEs.  Privacy, integrity, 
    freshness and authentication are also required across this 
    reference point in such a configuration.  Once appropriate security 
    has been established, the CE manager instructs CEs as to which FEs 
    they should control and how they should control them.  Figure 8 
    shows example of message exchange over Fc reference point. 
  
    As with the FE manager and FEs, configurations are possible where 
    the CE manager and CE are co-located and no protocol is used for 
    this function. 
     
 4.2. Post-association Phase and Fp reference point 
     
  
  
 Yang, et al.      Expires July    2004                   [Page 17]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    Post-association phase is the period of time during which an FE and 
    CE have been configured with information necessary to contact each 
    other and includes both association establishment and steady-state 
    communication.  The communication between CE and FE is performed 
    across the Fp ("p" meaning protocol) reference point. ForCES 
    Protocol is exclusively used for all communication across the Fp 
    reference point.  
     
 4.2.1. Proximity and Interconnect between CEs and FEs 
     
    The ForCES Working Group has made a conscious decision that the 
    first version of ForCES will be focused on "very close" CE/FE 
    localities in IP networks.  Very Close localities consist of 
    control and forwarding elements that either are components in the 
    same physical box, or are separated at most by one local network 
    hop ([7]).  CEs and FEs can be connected by a variety of 
    interconnect technologies, including Ethernet connections, 
    backplanes, ATM (cell) fabrics, etc.  ForCES should be able to 
    support each of these interconnects (see [3] Section 5, requirement 
    #1).  When the CEs and FEs are separated beyond a single L3 routing 
    hop, the ForCES Protocol will make use of an existing RFC2914 
    compliant L4 protocol with adequate reliability, security and 
    congestion control (e.g. TCP, SCTP) for transport purposes. 
     
 4.2.2. Association Establishment 
     
     
                 FE                      CE 
                 |                       | 
                 |(Security exchange.)   | 
                1|<--------------------->| 
                 |                       | 
                 |(Let me join the NE please.)    
                2|---------------------->| 
                 |                       | 
                 |(What kind of FE are you? -- capability query) 
                3|<----------------------| 
                 |                       | 
                 |(Here is my FE functions/state: use model to 
    describe) 
                4|---------------------->| 
                 |                       | 
                 |(Initial config for FE -- optional) 
                5|<----------------------| 
                 |                       | 
                 |(I am ready to go. Shall I?)     
                6|---------------------->| 
  
  
 Yang, et al.      Expires July    2004                   [Page 18]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
                 |                       | 
                 |(Go ahead!)            | 
                7|<----------------------| 
                 |                       | 
                  
          Figure 9. Example of message exchange between CE and FE 
                    over Fp to establish NE association 
     
    As an example, figure 9 shows some of the message exchange that may 
    happen before the association between the CE and FE is fully 
    established.  Either the CE or FE can initiate the connection.  
     
    Security handshake is necessary to authenticate the two 
    communication endpoints to each other before any further message 
    exchange can happen.  The security handshake should include mutual 
    authentication and authorization between the CE and FE, but the 
    exact details depend on the security solution chosen by ForCES 
    Protocol.  Authorization can be as simple as checking against the 
    list of authorized end points provided by the FE or CE manager 
    during the pre-association phase.  Both authentication and 
    authorization must be successful before the association can be 
    established.  If either authentication or authorization fails, the 
    end point must not be allowed to join the NE.  After the successful 
    security handshake, message authentication and confidentiality are 
    still necessary for the on-going information exchange between the 
    CE and FE, unless some form of physical security exists.  Whenever 
    a packet fails authentication, it must be dropped and a 
    notification may be sent to alert the sender of the potential 
    attack.  Section 8 provides more details on the security 
    considerations for ForCES.   
     
    After the successful security handshake, the FE needs to inform the 
    CE of its own capability and optionally its topology in relation to 
    other FEs. The capability of the FE is represented by the FE model, 
    described in a separate document.  The model would allow an FE to 
    describe what kind of packet processing functions it contains, in 
    what order the processing happens, what kinds of configurable 
    parameters it allows, what statistics it collects and what events 
    it might throw, etc.  Once such information is available to the CE, 
    the CE may choose to send some initial or default configuration to 
    the FE so that the FE can start receiving and processing packets 
    correctly.  Such initialization may not be necessary if the FE 
    already obtains the information from its own bootstrap process.  
    Once the necessary initial information is exchanged, the process of 
  
  
 Yang, et al.      Expires July    2004                   [Page 19]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    association is completed.  Packet processing and forwarding at the 
    FE cannot begin until association is established.  After the 
    association is established, the CE and FE enter steady-state 
    communication. 
     
     
 4.2.3. Steady-state Communication 
  
    Once an association is established between the CE and FE, the 
    ForCES Protocol is used by the CE and FE over Fp reference point to 
    exchange information to facilitate packet processing.  
     
                 FE                      CE 
                 |                       | 
                 |(Add these new routes.)| 
                1|<----------------------| 
                 |                       | 
                 |(Successful.)          | 
                2|---------------------->| 
                 |                       | 
                 |                       | 
                 |(Query some stats.)    | 
                1|<----------------------| 
                 |                       | 
                 |(Reply with stats collected.)           
                2|---------------------->| 
                 |                       | 
                 |                       | 
                 |(My port is down, with port #.)                     
                1|---------------------->| 
                 |                       | 
                 |(Here is a new forwarding table)                
                2|<----------------------|     
                 |                       | 
         Figure 10. Examples of message exchange between CE and FE 
                 over Fp during steady-state communication 
     
    Based on the information acquired through CEs' control processing, 
    CEs will frequently need to manipulate the packet-forwarding 
    behaviors of their FE(s) by sending instructions to FEs.  For 
    example, Figure 10 shows message exchange examples in which the CE 
    sends new routes to the FE so that the FE can add them to its 
    forwarding table.  The CE may query the FE for statistics collected 
    by the FE and the FE may notify the CE of important events such as 
    port failure. 
     
 4.2.4. Data Packets across Fp reference point 
  
  
 Yang, et al.      Expires July    2004                   [Page 20]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
     
         ---------------------           ---------------------- 
         |                   |           |                    | 
         |    +--------+     |           |     +--------+     | 
         |    |CE(BGP) |     |           |     |CE(BGP) |     | 
         |    +--------+     |           |     +--------+     | 
         |        |          |           |          ^         | 
         |        |Fp        |           |          |Fp       | 
         |        v          |           |          |         | 
         |    +--------+     |           |     +--------+     | 
         |    |  FE    |     |           |     |   FE   |     | 
         |    +--------+     |           |     +--------+     | 
         |        |          |           |          ^         | 
         | Router |          |           | Router   |         | 
         | A      |          |           | B        |         | 
         ---------+-----------           -----------+---------- 
                  v                                 ^ 
                  |                                 | 
                  |                                 | 
                  ------------------->---------------     
     
        Figure 11. Example to show data packet flow between two NEs. 
     
    Control plane protocol packets (such as RIP, OSPF messages) 
    addressed to any of NE's interfaces are typically redirected by the 
    receiving FE to its CE, and CE may originate packets and have its 
    FE deliver them to other NEs.  Therefore, ForCES Protocol over Fp 
    not only transports the ForCES Protocol messages between CEs and 
    FEs, but also encapsulates the data packets from control plane 
    protocols.  Moreover, one FE may be controlled by multiple CEs for 
    distributed control.  In this configuration, the control protocols 
    supported by the FORCES NEs may spread across multiple CEs.  For 
    example, one CE may support routing protocols like OSPF and BGP, 
    while a signaling and admission control protocol like RSVP is 
    supported in another CE.  FEs are configured to recognize and 
    filter these protocol packets and forward them to the corresponding 
    CE.  
  
    Figure 11 shows one example of how the BGP packets originated by 
    router A are passed to router B.  In this example, the ForCES 
    Protocol is used to transport the packets from the CE to the FE 
    inside router A, and then from the FE to the CE inside router B.  
    In light of the fact that the ForCES Protocol is responsible for 
    transporting both the control messages and the data packets between 
    the CE and FE over Fp reference point, it is possible to use either 
    a single protocol or multiple protocols to achieve this. 
     
  
  
 Yang, et al.      Expires July    2004                   [Page 21]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
 4.2.5. Proxy FE 
     
    In the case where a physical FE cannot implement (e.g., due to the 
    lack of a general purpose CPU) the ForCES Protocol directly, a 
    proxy FE can be used to terminate the Fp reference point instead of 
    the physical FE.  This allows the CE communicate to the physical FE 
    via the proxy by using ForCES, while the proxy manipulates the 
    physical FE using some intermediary form of communication (e.g., a 
    non-ForCES protocol or DMA).  In such an implementation, the 
    combination of the proxy and the physical FE becomes one logical FE 
    entity.  It is also possible that one proxy act on behalf of 
    multiple physical FEs. 
     
    One needs to be aware of the security implication introduced by the 
    proxy FE.  Since the physical FE is not capable of implementing 
    ForCES itself, the security mechanism of ForCES can only secure the 
    communication channel between the CE and the proxy FE, but not all 
    the way to the physical FE.  It is recommended that other security 
    mechanisms (including physical security property) be employed to 
    ensure the security between the CE and the physical FE.  
     
 4.3. Association Re-establishment 
     
    FEs and CEs may join and leave NEs dynamically (see [3] Section 5, 
    requirements #12).  When an FE or CE leaves the NE, the association 
    with the NE is broken.  If the leaving party rejoins an NE later, 
    to re-establish the association, it may need to re-enter the pre-
    association phase.  Loss of association can also happen 
    unexpectedly due to loss of connection between the CE and the FE.  
    Therefore, the framework allows the bi-directional transition 
    between these two phases, but the ForCES Protocol is only 
    applicable for the post-association phase.  However, the protocol 
    should provide mechanisms to support association re-establishment. 
    This includes the ability for CEs and FEs to determine when there 
    is a loss of association between them, ability to restore 
    association and efficient state (re)synchronization mechanisms (see 
    [3] Section 5, requirement #7). Note that security association and 
    state must be also re-established to guarantee the same level of 
    security (including both authentication and authorization) exists 
    before and after the association re-establishment. 
     
    When an FE leaves or joins an existing NE that is already in 
    operation, the CE needs to be aware of the impact on FE topology 
    and deals with the change accordingly. 
     
 4.3.1. CE graceful restart 
  
  
  
 Yang, et al.      Expires July    2004                   [Page 22]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    The failure and restart of the CE in a router can potentially cause 
    much stress and disruption on the control plane throughout a 
    network.  Because when a CE has to restart for any reason, the 
    router loses routing adjacencies or sessions with its routing 
    neighbors.  Neighbors who detect the lost adjacency normally re-
    compute new routes and then send routing updates to their own 
    neighbors to communicate the lost adjacency.  Their neighbors do 
    the same thing to propagate throughout the network.  In the 
    meantime, the restarting router cannot receive traffic from other 
    routers because the neighbors have stopped using the router's 
    previously advertised routes. When the restarting router restores 
    adjacencies, neighbors must once again re-compute new routes and 
    send out additional routing updates. The restarting router is 
    unable to forward packets until it has re-established routing 
    adjacencies with neighbors, received route updates through these 
    adjacencies, and computed new routes.  Until convergence takes 
    place throughout the network, packets may be lost in transient 
    black holes or forwarding loops.   
  
    A high availability mechanism known as the "graceful restart" has 
    been used by the IP routing protocols (OSPF [10], BGP [11]) and 
    MPLS label distribution protocol (LDP [9]) to help minimize the 
    negative effects on routing throughout an entire network caused by 
    a restarting router.  Route flap on neighboring routers is avoided, 
    and a restarting router can continue to forward packets that would 
    otherwise be dropped.   
     
    While the details differ from protocol to protocol, the general 
    idea behind the graceful restart mechanism remains the same.  With 
    the graceful restart, a restarting router can inform its neighbors 
    when it restarts.  The neighbors may detect the lost adjacency but 
    do not recompute new routes or send routing updates to their 
    neighbors.  The neighbors also hold on to the routes received from 
    the restarting router before restart and assume they are still 
    valid for a limited time.  By doing so, the restarting router's FEs 
    can also continue to receive and forward traffic from other 
    neighbors for a limited time by using the routes they already have. 
    The restarting router then re-establishes routing adjacencies, 
    downloads updated routes from all its neighbors, recomputes new 
    routes and uses them to replace the older routes it was using. It 
    then sends these updated routes to its neighbors and signals the 
    completion of the graceful restart process. 
     
    Non-stop forwarding is a requirement for graceful restart.  It is 
    necessary so a router can continue to forward packets while it is 
    downloading routing information and recomputing new routes.  This 
    ensures that packets will not be dropped.  As one can see, one of 
  
  
 Yang, et al.      Expires July    2004                   [Page 23]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    the benefits afforded by the separation of CE and FE is exactly the 
    ability of non-stop forwarding in the face of the CE failure and 
    restart.  The support of dynamic changes to CE/FE association in 
    ForCES also makes it compatible with high availability mechanisms 
    such as graceful restart. 
     
    ForCES should be able to support CE graceful restart easily.  When 
    the association is established the first time, the CE must inform 
    the FEs what to do in the case of CE failure.  If graceful restart 
    is not supported, the FEs may be told to stop packet processing all 
    together if its CE fails.  If graceful restart is supported, the 
    FEs should be told to cache and hold on to its FE state including 
    the forwarding tables across the restarts.  A timer must be 
    included so that the timeout causes such cached state to expire 
    eventually.  Those timers should be settable by the CE.  
  
 4.3.2. FE restart 
  
    In the same example in Figure 5, assuming CE1 is the working CE for 
    the moment, what would happen if one of the FEs, say FE1, leaves 
    the NE temporarily?  FE1 may voluntarily decide to leave the 
    association.  Alternatively, FE1 may stop functioning simply due to 
    unexpected failure.  In the former case, CE1 receives a "leave-
    association request" from FE1.  In the latter, CE1 detects the 
    failure of FE1 by some other means.  In both cases, CE1 must inform 
    the routing protocols of such an event, most likely prompting a 
    reachability and SPF (Shortest Path First) recalculation and 
    associated downloading of new FIBs from CE1 to the other remaining 
    FEs (only FE2 in this example).  Such recalculation and FIB update 
    will also be propagated from CE1 to the NE's neighbors that are 
    affected by the connectivity of FE1.   
     
    When FE1 decides to rejoin again, or when it restarts again from 
    the failure, FE1 needs to re-discover its master (CE).  This can be 
    achieved by several means.  It may re-enter the pre-association 
    phase and get that information from its FE manager.  It may 
    retrieve the previous CE information from its cache, if it can 
    validate the information freshness.  Once it discovers its CE, it 
    starts message exchange with the CE to re-establish the association 
    just as outlined in Figure 9, with the possible exception that it 
    might be able to bypass the transport of the complete initial 
    configuration.  Suppose that FE1 still has its routing table and 
    other state information from the last association. Instead of 
    sending all the information again from scratch, it may be able to 
    use more efficient mechanism to re-sync up the state with its CE if 
    such mechanism is supported by the ForCES Protocol.  For example, 
    CRC-32 of the state might give a quick indication of whether or not 
  
  
 Yang, et al.      Expires July    2004                   [Page 24]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    the state is in-sync with its CE.  By comparing its state with the 
    CE first, it sends an information update only if it is needed.  
    ForCES Protocol may choose to implement similar optimization 
    mechanisms, but it may also choose not to, as this is not a 
    requirement. 
     
     
 5. Applicability to RFC1812  
  
    [3] Section 5, requirement #9 dictates "Any proposed ForCES 
    architecture must explain how that architecture supports all of the 
    router functions as defined in RFC1812."  RFC1812 discusses many 
    important requirements for IPv4 routers from the link layer to the 
    application layer.  This section addresses the relevant 
    requirements in RFC1812 for implementing IPv4 routers based on 
    ForCES architecture and explains how ForCES satisfies these 
    requirements by providing guidelines on how to separate the 
    functionalities required into forwarding plane and control plane.   
     
    In general, the forwarding plane carries out the bulk of the per-
    packet processing that is required at line speed, while the control 
    plane carries most of the computationally complex operations that 
    are typical of the control and signaling protocols.  However, it is 
    impossible to draw a rigid line to divide the processing into CEs 
    and FEs cleanly.  Nor should the ForCES architecture limit the 
    innovative approaches in control and forwarding plane separation.  
    As more and more processing power is available in the FEs, some of 
    the control functions that traditionally are performed by CEs may 
    now be moved to FEs for better performance and scalability.  Such 
    offloaded functions may include part of ICMP or TCP processing, or 
    part of routing protocols.  Once off-loaded onto the forwarding 
    plane, such CE functions, even though logically belonging to the 
    control plane, now become part of the FE functions.  Just like the 
    other logical functions performed by FEs, such off-loaded functions 
    must be expressed as part of the FE model so that the CEs can 
    decide how to best take advantage of these off-loaded functions 
    when present on the FEs. 
     
 5.1. General Router Requirements 
  
    Routers have at least two or more logical interfaces.  When CEs and 
    FEs are separated by ForCES within a single NE, some additional 
    interfaces are needed for intra-NE communications.  Figure 12 shows 
    an example to illustrate that.  This NE contains one CE and two 
    FEs.  Each FE has four interfaces; two of them are used for 
    receiving and transmitting packets to the external world, while the 
    other two are for intra-NE connections.  CE has two logical 
  
  
 Yang, et al.      Expires July    2004                   [Page 25]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    interfaces #9 and #10, connected to interfaces #3 and #6 from FE1 
    and FE2, respectively.  Interface #4 and #5 are connected for FE1-
    FE2 communication.  Therefore, this router NE provides four 
    external interfaces (#1, 2, 7 and 8).  
  
                 --------------------------------- 
                 |               router NE       | 
                 |   -----------   -----------   | 
                 |   |   FE1   |   |   FE2   |   | 
                 |   -----------   -----------   | 
                 |   1| 2| 3| 4|   5| 6| 7| 8|   | 
                 |    |  |  |  |    |  |  |  |   | 
                 |    |  |  |  +----+  |  |  |   | 
                 |    |  |  |          |  |  |   | 
                 |    |  | 9|        10|  |  |   | 
                 |    |  | -------------- |  |   | 
                 |    |  | |    CE      | |  |   | 
                 |    |  | -------------- |  |   | 
                 |    |  |                |  |   | 
                 -----+--+----------------+--+---- 
                      |  |                |  |  
                      |  |                |  |  
     
                 Figure 12. A router NE example with four interfaces. 
  
    IPv4 routers must implement IP to support its packet forwarding 
    function, which is driven by its FIB (Forwarding Information Base). 
    This Internet layer forwarding (see RFC1812 [1] Section 5) 
    functionality naturally belongs to FEs in the ForCES architecture.  
     
    A router may implement transport layer protocols (like TCP and UDP) 
    that are required to support application layer protocols (see 
    RFC1812 [1] Section 6).  One important class of application 
    protocols is routing protocols (see RFC1812 [1] Section 7).  In 
    ForCES architecture, routing protocols are naturally implemented by 
    CEs.  Routing protocols require routers communicate with each 
    other.  This communication between CEs in different routers is 
    supported in ForCES by FEs' ability to redirect data packets 
    addressed to routers (i.e., NEs) and CEs' ability to originate 
    packets and have them delivered by their FEs.  This communication 
    occurs across Fp reference point inside each router and between 
    neighboring routers' external interfaces, as illustrated in Figure 
    11.  
     
 5.2.Link Layer 
     
  
  
 Yang, et al.      Expires July    2004                   [Page 26]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    Since FEs own all the external interfaces for the router, FEs need 
    to conform to the link layer requirements in RFC1812.  Arguably, 
    ARP support may be implemented in either CEs or FEs.  As we will 
    see later, a number of behaviors that RFC1812 mandates fall into 
    this category -- they may be performed by the FE and may be 
    performed by the CE.  A general guideline is needed to ensure 
    interoperability between separated control and forwarding planes.  
    The guideline we offer here is that CEs MUST be capable of these 
    kind of operations while FEs MAY choose to implement them.  FE 
    model should indicate its capabilities in this regard so that CEs 
    can decide where these functions are implemented. 
     
    Interface parameters, including MTU, IP address, etc., must be 
    configurable by CEs via ForCES.  CEs must be able to determine 
    whether a physical interface in an FE is available to send packets 
    or not.  FEs must also inform CEs the status change of the 
    interfaces (like link up/down) via ForCES. 
     
 5.3.Internet Layer Protocols 
     
    Both FEs and CEs must implement IP protocol and all mandatory 
    extensions as RFC1812 specified.  CEs should implement IP options 
    like source route and record route while FEs may choose to 
    implement those as well.  The timestamp option should be 
    implemented by FEs to insert the timestamp most accurately.  The FE 
    must interpret the IP options that it understands and preserve the 
    rest unchanged for use by CEs.  Both FEs and CEs might choose to 
    silently discard packets without sending ICMP errors, but such 
    events should be logged and counted.  FEs may report statistics for 
    such events to CEs via ForCES.  
  
    When multiple FEs are involved to process packets, the appearance 
    of single NE must be strictly maintained.  For example, Time-To-
    Live (TTL) must be decremented only once within a single NE.  For 
    example, it can be always decremented by the last FE with egress 
    function.  
     
    FEs must receive and process normally any packets with a broadcast 
    destination address or a multicast destination address that the 
    router has asked to receive.  When IP multicast is supported in 
    routers, IGMP is implemented in CEs.  CEs are also required of ICMP 
    support, while it is optional for FEs to support ICMP.  Such an 
    option can be communicated to CEs as part of the FE model.  
    Therefore, FEs can always rely upon CEs to send out ICMP error 
    messages, but FEs also have the option to generate ICMP error 
    messages themselves.  
     
  
  
 Yang, et al.      Expires July    2004                   [Page 27]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
 5.4.Internet Layer Forwarding 
     
    IP forwarding is implemented by FEs.  When the routing table is 
    updated at CEs, ForCES is used to send the new route entries from 
    CEs to FEs.  Each FE has its own forwarding table and uses this 
    table to direct packets to the next hop interface.  
     
    Upon receiving IP packets, the FE verifies the IP header and 
    processes most of the IP options.  Some options cannot be processed 
    until the routing decision has been made.  The routing decision is 
    made after examining the destination IP address.  If the 
    destination address belongs to the router itself, the packets are 
    filtered and either processed locally or forwarded to CE, depending 
    upon the instructions set-up by CE.  Otherwise, the FE determines 
    the next hop IP address by looking up in its forwarding table.  The 
    FE also determines the network interface it uses to send the 
    packets.  Sometimes an FE may need to forward the packets to 
    another FE before packets can be forwarded out to the next hop.  
    Right before packets are forwarded out to the next hop, the FE 
    decrements TTL by 1 and processes any IP options that cannot be 
    processed before.  The FE performs any IP fragmentation if 
    necessary, determines link layer address (e.g., by ARP), and 
    encapsulates the IP datagram (or each of the fragments thereof) in 
    an appropriate link layer frame and queues it for output on the 
    interface selected. 
     
    Other options mentioned in RFC1812 for IP forwarding may also be 
    implemented at FEs, for example, packet filtering. 
     
    FEs typically forward packets destined locally to CEs.  FEs may 
    also forward exceptional packets (packets that FEs do not know how 
    to handle) to CEs.  CEs are required to handle packets forwarded by 
    FEs for whatever different reasons.  It might be necessary for 
    ForCES to attach some meta-data with the packets to indicate the 
    reasons of forwarding from FEs to CEs.  Upon receiving packets with 
    meta-data from FEs, CEs can decide to either process the packets 
    themselves, or pass the packets to the upper layer protocols 
    including routing and management protocols.  If CEs are to process 
    the packets by themselves, CEs may choose to discard the packets, 
    or modify and re-send the packets.  CEs may also originate new 
    packets and deliver them to FEs for further forwarding.  
     
    Any state change during router operation must also be handled 
    correctly according to RFC1812.  For example, when an FE ceases 
    forwarding, the entire NE may continue forwarding packets, but it 
    needs to stop advertising routes that are affected by the failed 
    FE.  
  
  
 Yang, et al.      Expires July    2004                   [Page 28]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
      
 5.5. Transport Layer  
     
    Transport layer is typically implemented at CEs to support higher 
    layer application protocols like routing protocols.  In practice, 
    this means that most CEs implement both the Transmission Control 
    Protocol (TCP) and the User Datagram Protocol (UDP). 
     
    Both CEs and FEs need to implement ForCES Protocol.  If some layer-
    4 transport is used to support ForCES, then both CEs and FEs need 
    to implement the L4 transport and ForCES Protocols.   
  
 5.6. Application Layer -- Routing Protocols 
     
    Interior and exterior routing protocols are implemented on CEs.  
    The routing packets originated by CEs are forwarded to FEs for 
    delivery.  The results of such protocols (like forwarding table 
    updates) are communicated to FEs via ForCES. 
     
    For performance or scalability reasons, portions of the control 
    plane functions that need faster response may be moved from the CEs 
    and off-loaded onto the FEs.  For example in OSPF, the Hello 
    protocol packets are generated and processed periodically.  When 
    done at CEs, the inbound Hello packets have to traverse from the 
    external interfaces at the FEs to the CEs via the internal CE-FE 
    channel.  Similarly, the outbound Hello packets have to go from the 
    CEs to the FEs and to the external interfaces.  Frequent Hello 
    updates place heavy processing overhead on the CEs and can 
    overwhelm the CE-FE channel as well.  Since typically there are far 
    more FEs than CEs in a router, the off-loaded Hello packets are 
    processed in a much more distributed and scalable fashion.  By 
    expressing such off-loaded functions in the FE model, we can ensure 
    interoperability. However, the exact description of the off-loaded 
    functionality corresponding to the off-loaded functions expressed 
    in the FE model are not part of the model itself and will need to 
    be worked out as a separate specification. 
  
 5.7. Application Layer -- Network Management Protocol 
     
    RFC1812 also dictates "Routers MUST be manageable by SNMP."  In 
    general, for post-association phase, most external management tasks 
    (including SNMP) should be done through interaction with the CE in 
    order to support the appearance of a single functional device.  
    Therefore, it is recommended that SNMP agent be implemented by CEs 
    and the SNMP messages received by FEs be redirected to their CEs.  
    AgentX framework defined in RFC2741 ([5]) may be applied here such 
    that CEs act in the role of master agent to process SNMP protocol 
  
  
 Yang, et al.      Expires July    2004                   [Page 29]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    messages while FEs act in the role of subagent to provide access to 
    the MIB objects residing on FEs.  AgentX protocol messages between 
    the master agent (CE) and the subagent (FE) are encapsulated and 
    transported via ForCES, just like data packets from any other 
    application layer protocols.  
  
 6. Summary 
     
    This document defines an architectural framework for ForCES.  It 
    identifies the relevant components for a ForCES network element, 
    including (one or more) FEs, (one or more) CEs, one optional FE 
    manager, and one optional CE manager.  It also identifies the 
    interaction among these components and discusses all the major 
    reference points.  It is important to point out that, among all the 
    reference points, only the Fp interface between CEs and FEs is 
    within the scope of ForCES.  ForCES alone may not be enough to 
    support all desirable NE configurations.  However, we believe that 
    ForCES over Fp interface is the most important element in realizing 
    physical separation and interoperability of CEs and FEs, and hence 
    the first interface that ought to be standardized.  Simple and 
    useful configurations can still be implemented with only CE-FE 
    interface being standardized, e.g., single CE with full-meshed FEs. 
     
 7. Acknowledgements 
     
    Joel M. Halpern gave us many insightful comments and suggestions 
    and pointed out several major issues.  T. Sridhar suggested that 
    the AgentX protocol could be used with SNMP to manage the ForCES 
    network elements.  Susan Hares pointed out the issue of graceful 
    restart with ForCES.  Russ Housley, Avri Doria, Jamal Hadi Salim 
    and many others in the ForCES mailing list also provided valuable 
    feedback. 
     
 8. Security Considerations 
     
    The NE administrator has the freedom to determine the exact 
    security configuration that is needed for the specific deployment. 
    For example, ForCES may be deployed between CEs and FEs connected 
    to each other inside a box over a backplane.  In such scenario, 
    physical security of the box ensures that most of the attacks such 
    as man-in-the-middle, snooping, and impersonation are not possible, 
    and hence ForCES architecture may rely on the physical security of 
    the box to defend against these attacks and protocol mechanisms may 
    be turned off.  However, it is also shown that denial of service 
    attack via external interface as described below in Section 8.1.8 
    is still a potential threat even for such "all-in-one-box" 
    deployment scenario and hence the rate limiting mechanism is still 
  
  
 Yang, et al.      Expires July    2004                   [Page 30]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    necessary.  This is just one example to show that it is important 
    to assess the security needs of the ForCES-enabled network elements 
    under different deployment scenarios.  It should be possible for 
    the administrator to configure the level of security needed for the 
    ForCES Protocol. 
     
    In general, the physical separation of two entities usually results 
    in a potentially insecure link between the two entities and hence 
    much stricter security measurements are required.  For example, we 
    pointed out in Section 4.1 that authentication becomes necessary 
    between CE manager and FE manager, between CE and CE manager, 
    between FE and FE manager in some configurations.  The physical 
    separation of CE and FE also imposes serious security requirement 
    for ForCES Protocol over Fp interface.  This section first attempts 
    to describe the security threats that may be introduced by the 
    physical separation of the FEs and the CEs, and then it provides 
    recommendation and guidelines for secure operation and management 
    of ForCES Protocol over Fp interface based on existing standard 
    security solutions. 
     
 8.1. Analysis of Potential Threats Introduced by ForCES 
     
    This section provides the threat analysis for ForCES, with a focus 
    on Fp interface.  Each threat is described in details with the 
    effects on the ForCES Protocol entities or/and the NE as a whole, 
    and the required functionalities that need to be in place to defend 
    the threat.  
  
 8.1.1. "Join" or "Remove" Message Flooding on CEs 
     
    Threats:  A malicious node could send a stream of false "join NE" 
    or "remove from NE" requests on behalf of non-existent or 
    unauthorized FE to legitimate CEs at a very rapid rate and thereby 
    create unnecessary state in the CEs. 
     
    Effects: If by maintaining state for non-existent or unauthorized 
    FEs, a CE may become unavailable for other processing and hence 
    suffer from denial of service (DoS) attack similar to the TCP SYN 
    DoS.  If multiple CEs are used, the unnecessary state information 
    may also be conveyed to multiple CEs via Fr interface (e.g., from 
    the active CE to the stand-by CE) and hence subject multiple CEs to 
    DoS attack.  
        
    Requirement:  A CE that receives a "join" or "remove" request 
    should not create any state information until it has authenticated 
    the FE endpoint. 
     
  
  
 Yang, et al.      Expires July    2004                   [Page 31]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
     
 8.1.2. Impersonation Attack  
     
    Threats: A malicious node can impersonate a CE or FE and send out 
    false messages. 
     
    Effects: The whole NE could be compromised. 
  
    Requirement:  The CE or FE must authenticate the message as having 
    come from an FE or CE on the list of the authorized ForCES elements 
    (provided by the CE or FE Manager in the pre-association phase) 
    before accepting and processing it.   
     
     
 8.1.3. Replay Attack 
     
    Threat: A malicious node could replay the entire message previously 
    sent by an FE or CE entity to get around authentication.  
     
    Effect: The NE could be compromised. 
     
    Requirement:  Replay protection mechanism needs to be part of the 
    security solution to defend against this attack. 
      
 8.1.4. Attack during Fail Over 
      
    Threat: A malicious node may exploit the CE fail-over mechanism to 
    take over the control of NE. For example, suppose two CEs, say CE-A 
    and CE-B, are controlling several FEs. CE-A is active and CE-B is 
    stand-by.  When CE-A fails, CE-B is taking over the active CE 
    position.  The FEs already had a trusted relationship with CE-A, 
    but the FEs may not have the same trusted relationship established 
    with CE-B prior to the fail-over.  A malicious node can take over 
    as CE-B if such trusted relationship has not been established prior 
    or during the fail-over.  
     
    Effect: The NE may be compromised after such insecure fail-over. 
     
    Requirement:  The level of trust relationship between the stand-by 
    CE and the FEs must be as strong as the one between the active CE 
    and the FEs.  The security association between the FEs and the 
    stand-by CE may be established prior to fail-over.  If not already 
    in place, such security association must be re-established before 
    the stand-by CE takes over. 
      
 8.1.5.  Data Integrity  
     
  
  
 Yang, et al.      Expires July    2004                   [Page 32]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    Threats: A malicious node may inject false messages to legitimate 
    CE or FE.     
     
    Effect: An FE or CE receives the fabricated packet and performs 
    incorrect or catastrophic operation. 
     
    Requirement: Protocol messages require integrity protection. 
     
 8.1.6.  Data Confidentiality 
     
    Threat: When FE and CE are physically separated, a malicious node 
    may eavesdrop the messages in transit.  Some of the messages are 
    critical to the functioning of the whole network, while others may 
    contain confidential business data.  Leaking of such information 
    may result in compromise even beyond the immediate CE or FE.  
      
    Effect: Sensitive information might be exposed between CE and FE. 
     
    Requirement: Data confidentiality between FE and CE must be 
    available for sensitive information. 
  
 8.1.7. Sharing security parameters 
     
    Threat: Consider a scenario where several FEs communicating to the 
    same CE share the same authentication keys for the Fp interface.  
    If any FE or the CE is compromised, all other entities are 
    compromised. 
     
    Effect: The whole NE is compromised. 
      
    Recommendation: To avoid this side effect, it's better to configure 
    different security parameters for each FE-CE communication over Fp 
    interface. 
     
 8.1.8. Denial of Service Attack via External Interface 
     
    Threat: When an FE receives a packet that is destined for its CE, 
    the FE forwards the packet over the Fp interface.  Malicious node 
    can generate huge message storm like routing protocol packets etc. 
    through the external Fi/f interface so that the FE has to process 
    and forward all packets to CE through Fp interface. 
     
    Effect: CE encounters resource exhaustion and bandwidth starvation 
    on Fp interface due to an overwhelming number of packets from FEs. 
     
    Requirement: Some sort of rate limiting mechanism MUST to be in 
    place at both the FE and CE.  Rate Limiter SHOULD be configured at 
  
  
 Yang, et al.      Expires July    2004                   [Page 33]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    the FE for each message type that are being received through Fi/F 
    interface. 
          
 8.2. Security Recommendations for ForCES 
  
    The requirements document [3] suggested that ForCES Protocol should 
    support reliability over Fp interface, but no particular transport 
    protocol is yet specified for ForCES.  This framework document does 
    not intend to specify the particular transport either, and so we 
    only provide recommendations and guidelines based on the existing 
    standard security protocols [18] that can work with the common 
    transport candidates suitable for ForCES. 
      
    We review two existing security protocol solutions, namely IPsec 
    (IP Security) [14] or TLS (Transport Layer Security) [13].  TLS 
    works with reliable transports such as TCP or SCTP for unicast, 
    while IPsec can be used with any transport (UDP, TCP, SCTP) and 
    supports both unicast and multicast.  Both TLS and IPsec can be 
    used potentially to satisfy all of the security requirements for 
    ForCES Protocol.  In addition, other approaches may be used as well 
    but are not documented here, including using L2 security mechanisms 
    for a given L2 interconnect technology, as long as the requirements 
    can be satisfied.  
                                                
    When ForCES is deployed between CEs and FEs inside a box or a 
    physically secured room, authentication, confidentiality and 
    integrity may be provided by the physical security of the box and 
    so the security mechanisms may be turned off, depending on the 
    networking topology and its administration policy.  However, it is 
    important to realize that even if the NE is in a single-box, the 
    DoS attacks as described in Section 8.1.8 can still be launched 
    through Fi/f interfaces.  Therefore, it is important to have the 
    corresponding counter-measurement in place even for single-box 
    deployment. 
  
 8.2.1. Using TLS with ForCES 
     
    TLS [13] can be used if a reliable unicast transport such as TCP or 
    SCTP is used for ForCES over the Fp interface.  The TLS handshake 
    protocol is used during association establishment or re-
    establishment phase to negotiate a TLS session between the CE and 
    FE.  Once the session is in place, the TLS record protocol is used 
    to secure ForCES communication messages between the CE and FE. 
     
    A basic outline of how TLS can be used with ForCES is described 
    below.  Steps 1) till 7) complete the security handshake as 
    illustrated in Figure 9 while step 8) is for all the further 
  
  
 Yang, et al.      Expires July    2004                   [Page 34]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    communication between the CE and FE, including the rest of messages 
    after the security handshake shown in Figure 9 and the steady-state 
    communication shown in Figure 10. 
     
         1) During Pre-association phase all FEs are configured with 
         the CEs (including both the active CE and the standby CE).  
         2) The FE establishes a TLS connection with the CE (master) 
         and negotiates a cipher suite. 
         3) The FE (slave) gets the CE certificate, validates the 
         signature, checks the expiration date, checks if the 
         certificate has been revoked. 
         4) The CE (master) gets the FE certificate and performs the 
         same validation as the FE in step 3).  
         5) If any of the check fails in step 3) or step 4), endpoint 
         must generate an error message and abort. 
         6) After successful mutual authentication, a TLS session is 
         established between CE and FE. 
         7) The FE sends a "join NE" message to the CE.   
         8) The FE and CE use TLS session for further communication. 
     
    Note that there are different ways for the CE and FE to validate a 
    received certificate.  One way is to configure the FE Manager or CE 
    Manager or other central component as CA, so that the CE or FE can 
    query this pre-configured CA to validate that the certificate has 
    not been revoked.  Another way is to have the CE and the FE 
    configured directly a list of valid certificates in the pre-
    association phase.  
     
    In the case of fail-over, it is the responsibility of the active CE 
    and the standby CE to synchronize ForCES states including the TLS 
    states to minimize the state reestablishment during fail-over.  
    Care must be taken to ensure that the standby CE is also 
    authenticated in the same way as the active CE, either before or 
    during the fail-over. 
  
 8.2.2. Using IPsec with ForCES 
     
    IPsec [14] can be used with any transport protocol, such as UDP, 
    SCTP and TCP over Fp interface for ForCES.  When using IPsec, we 
    recommend using ESP in transport mode for ForCES because message 
    confidentiality is required for ForCES.  
     
    IPsec can be used with both manual and automated SA and 
    cryptographic key management.  But IPsec's replay protection 
    mechanisms are not available if manual key management is used.  
    Hence, automatic key management is recommended if replay protection 
    is deemed important.  Otherwise, manual key management might be 
  
  
 Yang, et al.      Expires July    2004                   [Page 35]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    sufficient for some deployment scenarios, esp. when the number of 
    CEs and FEs is relatively small.  It is recommended that the keys 
    be changed periodically even for manual key management. 
     
    IPsec can support both unicast and multicast transport. At the time 
    this document was published, MSEC working group is actively working 
    on standardizing protocols to provide multicast security [17]. 
    Multicast-based solutions relying on IPsec should specify how to 
    meet the security requirements in [3].  
     
    Unlike TLS, IPsec provides security services between the CE and FE 
    at IP level, and so the security handshake as illustrated in Figure 
    9 amounts to a "no-op" when manual key management is used.  The 
    following outline the steps taken for ForCES in such a case. 
     
         1) During Pre-association phase all FEs are configured with 
         the CEs (including active CE and standby CE) and SA parameters 
         manually. 
         2) The FE sends a "join NE" message to the CE.  This message 
         and all others that follow are afforded security service 
         according to the manually configured IPsec SA parameters, but 
         replay protection is not available.  
     
    It is up to the administrator to decide whether to share the same 
    key across multiple FE-CE communication, but it is recommended that 
    different keys be used.  Similarly, it is recommended that 
    different keys be used for inbound and outbound traffic. 
  
    If automatic key management is needed, IKE [15] can be used for 
    that purpose. Other automatic key distribution techniques such as 
    Kerberos may be used as well.   The key exchange process 
    constitutes the security handshake as illustrated in Figure 9.  The 
    following shows the steps involved in using IKE with IPsec for 
    ForCES.  Steps 1) to 6) constitute the security handshake in Figure 
    9. 
     
         1) During Pre-association phase all FEs are configured with 
         the CEs (including active CE and standby CE), IPsec policy 
         etc. 
         2) The FE kicks off IKE process and tries to establish an 
         IPsec SA with the CE (master).  The FE (Slave) gets the CE 
         certificate as part of the IKE negotiation.  The FE validates 
         signature, checks the expiration date, checks if the 
         certificate has been revoked. 
         3) The CE (master) gets the FE certificate and performs the 
         same check as the FE in step 2). 
  
  
 Yang, et al.      Expires July    2004                   [Page 36]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
         4) If any of the check fails in step 2) or step 3), the 
         endpoint must generate an error message and abort. 
         5) After successful mutual authentication, IPsec session is 
         established between the CE and FE. 
         6) The FE sends a "join NE" message to CE.  No SADB entry is 
         created in FE yet. 
         7) The FE and CE use the IPsec session for further 
         communication. 
      
    FE Manager or CE Manager or other central component can be used as 
    CA for validating CE and FE certificates during the IKE process.   
    Alternatively, during the pre-association phase, the CE and FE can 
    be configured directly with the required information such as 
    certificates or passwords etc depending upon the type of 
    authentication that administrator wants to configure.  
          
    In the case of fail-over, it is the responsibility of active CE and 
    standby CE to synchronize ForCES states and IPsec states to 
    minimize the state reestablishment during fail-over.  
    Alternatively, the FE needs to establish different IPsec SA during 
    the startup operation itself with each CE.  This will minimize the 
    periodic state transfer across IPsec layer though Fr (CE-CE) 
    Interface.  
     
 9. Normative References 
  
    [1] Baker, F., "Requirements for IP Version 4 Routers", RFC 1812, 
    June 1995. 
     
    [2] Floyd, S., "Congestion Control Principles", RFC 2914, September 
    2000. 
     
    [3] Khosravi, H. and Anderson, T., "Requirements for Separation of 
    IP Control and Forwarding", RFC 3654, November 2003. 
     
 10. Informative References 
     
    [4] Case, J., et al., "Introduction and Applicability Statements 
    for Internet Standard Management Framework", RFC 3410, December 
    2002. 
     
    [5] Daniele, M. et al., "Agent Extensibility (AgentX) Protocol 
    Version 1", RFC 2741, January 2000. 
     
    [6] Chan, K. et al., "COPS Usage for Policy Provisioning (COPS-
    PR)", RFC 3084, March 2001. 
     
  
  
 Yang, et al.      Expires July    2004                   [Page 37]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    [7] Crouch, A. et al., "ForCES Applicability Statement", work in 
    progress, June 2003, <draft-ietf-forces-applicability-02.txt>. 
     
    [8] Anderson, T. and J. Buerkle, "Requirements for the Dynamic 
    Partitioning of Switching Elements", RFC 3532, May 2003. 
     
    [9] Leelanivas, M. et al., "Graceful Restart Mechanism for Label 
    Distribution Protocol", RFC 3478, February 2003. 
     
    [10] Moy, J. et al., "Graceful OSPF Restart", RFC 3623, November 
    2003. 
     
    [11] Sangli, S. et al., "Graceful Restart Mechanism for BGP", work 
    in progress, September 2003, < draft-ietf-idr-restart-08.txt>. 
     
    [12] Shand, M. and L. Ginsberg, "Restart Signaling for IS-IS", work 
    in progress, July 2003, <draft-ietf-isis-restart-04.txt>. 
     
    [13] Dierks, T. and C. Allen, "The TLS Protocol, version 1.0", RFC 
    2246, January 1999. 
     
    [14] Kent, S. and R. Atkinson, "Security Architecture for the 
    Internet Protocol", RFC 2401, November 1998. 
     
    [15] Harkins, D. and D. Carrel, "The Internet Key Exchange (IKE) ", 
    RFC 2409, November 1998. 
     
    [16] Bellovin, S., "Guidelines for Mandating the Use of Ipsec", 
    work in progress, October 2003, <draft-bellovin-useipsec-02.txt>. 
     
    [17] Hardjono, T. and Weis, B. "The Multicast Security 
    Architecture", work in progress, November 2003, <draft-ietf-msec-
    arch-04.txt>. 
     
    [18] S. Bellovin, J. Schiller, and C. Kaufman, "Security Mechanisms 
    for the Internet", RFC 3631, December, 2003. 
     
 11. Authors' Addresses 
  
    L. Lily Yang 
    Intel Corp., MS JF3-206, 
    2111 NE 25th Avenue 
    Hillsboro, OR 97124, USA 
    Phone: +1 503 264 8813 
    Email: lily.l.yang@intel.com 
     
    Ram Dantu 
  
  
 Yang, et al.      Expires July    2004                   [Page 38]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    Department of Computer Science, 
    University of North Texas, 
    Denton, TX 76203, USA 
    Phone: +1 940 565 2822 
    Email: rdantu@unt.edu 
  
    Todd A. Anderson 
    Intel Corp. 
    2111 NE 25th Avenue 
    Hillsboro, OR 97124, USA 
    Phone: +1 503 712 1760 
    Email: todd.a.anderson@intel.com 
     
    Ram Gopal 
    Nokia Research Center 
    5, Wayside Road, 
    Burlington, MA 01803, USA 
    Phone: +1 781 993 3685 
    Email: ram.gopal@nokia.com 
  
 12. Intellectual Property Right 
     
    The IETF takes no position regarding the validity or scope of any 
    intellectual property or other rights that might be claimed to 
    pertain to the implementation or use of the technology described in 
    this document or the extent to which any license under such rights 
    might or might not be available; neither does it represent that it 
    has made any effort to identify any such rights.  Information on 
    the IETF's procedures with respect to rights in standards-track and 
    standards-related documentation can be found in RFC 2026.  Copies 
    of claims of rights made available for publication and any 
    assurances of licenses to be made available, or the result of an 
    attempt made to obtain a general license or permission for the use 
    of such proprietary rights by implementors or users of this 
    specification can be obtained from the IETF Secretariat. 
     
    The IETF invites any interested party to bring to its attention any 
    copyrights, patents or patent applications, or other proprietary 
    rights which may cover technology that may be required to practice 
    this standard.  Please address the information to the IETF 
    Executive Director. 
     
 13. Full Copyright Statement 
        
    Copyright (C) The Internet Society (2003). All Rights Reserved. 
     
  
  
 Yang, et al.      Expires July    2004                   [Page 39]  

 Internet Draft         ForCES Framework                 January 2004 
  
  
    This document and translations of it may be copied and furnished to 
    others, and derivative works that comment on or otherwise explain 
    it or assist in its implementation may be prepared, copied, 
    published and distributed, in whole or in part, without restriction 
    of any kind, provided that the above copyright notice and this 
    paragraph are included on all such copies and derivative works.  
    However, this document itself may not be modified in any way, such 
    as by removing the copyright notice or references to the Internet 
    Society or other Internet organizations, except as needed for the 
    purpose of developing Internet standards in which case the 
    procedures for copyrights defined in the Internet Standards process 
    must be followed, or as required to translate it into languages 
    other than English. 
     
    The limited permissions granted above are perpetual and will not be 
    revoked by the Internet Society or its successors or assigns. 
    This document and the information contained herein is provided on 
    an "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET 
    ENGINEERING TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR 
    IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF 
    THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED 
    WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE." 
     
  
  
 Yang, et al.      Expires July    2004                   [Page 40]