Abstract

   This document defines a YANG module for alarm management.  It
   includes functions for alarm list management, alarm shelving and
   notifications to inform management systems.  There are also RPCs to
   manage the operator state of an alarm and administrative alarm
   procedures.  The module carefully maps to relevant alarm standards.

Status of This Memo

   This Internet-Draft is submitted in full conformance with the
   provisions of BCP 78 and BCP 79.

   Internet-Drafts are working documents of the Internet Engineering
   Task Force (IETF).  Note that other groups may also distribute
   working documents as Internet-Drafts.  The list of current Internet-
   Drafts is at http://datatracker.ietf.org/drafts/current/.

   Internet-Drafts are draft documents valid for a maximum of six months
   and may be updated, replaced, or obsoleted by other documents at any
   time.  It is inappropriate to use Internet-Drafts as reference
   material or to cite them other than as "work in progress."

   This Internet-Draft will expire on November 9, 2017.

Copyright Notice

   Copyright (c) 2017 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (http://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.  Code Components extracted from this document must
   include Simplified BSD License text as described in Section 4.e of

Vallin & Bjorklund      Expires November 9, 2017                [Page 1]
Internet-Draft              YANG Alarm Module                   May 2017

   the Trust Legal Provisions and are provided without warranty as
   described in the Simplified BSD License.

Table of Contents

   1.  Requirements notation . . . . . . . . . . . . . . . . . . . .   3
   2.  Introduction  . . . . . . . . . . . . . . . . . . . . . . . .   3
     2.1.  Terminology . . . . . . . . . . . . . . . . . . . . . . .   3
   3.  Objectives  . . . . . . . . . . . . . . . . . . . . . . . . .   4
   4.  Background and Usability Requirements . . . . . . . . . . . .   5
   5.  Alarm Concepts  . . . . . . . . . . . . . . . . . . . . . . .   8
     5.1.  What is an Alarm? . . . . . . . . . . . . . . . . . . . .   9
     5.2.  What is an Alarm Type?  . . . . . . . . . . . . . . . . .   9
     5.3.  How are Resources Identified? . . . . . . . . . . . . . .  12
     5.4.  How are Alarm Instances Identified? . . . . . . . . . . .  12
     5.5.  What is the Life-Cycle of an Alarm? . . . . . . . . . . .  13
       5.5.1.  Resource Alarm Life-Cycle . . . . . . . . . . . . . .  13
       5.5.2.  Operator Alarm Life-cycle . . . . . . . . . . . . . .  14
       5.5.3.  Administrative Alarm Life-Cycle . . . . . . . . . . .  14
     5.6.  Root Cause and Impacted Resources . . . . . . . . . . . .  15
     5.7.  Alarm Shelving  . . . . . . . . . . . . . . . . . . . . .  15
   6.  Alarm Data Model  . . . . . . . . . . . . . . . . . . . . . .  15
     6.1.  Alarm Control . . . . . . . . . . . . . . . . . . . . . .  17
       6.1.1.  Alarm Shelving  . . . . . . . . . . . . . . . . . . .  18
     6.2.  Alarm Inventory . . . . . . . . . . . . . . . . . . . . .  18
     6.3.  Alarm Summary . . . . . . . . . . . . . . . . . . . . . .  19
     6.4.  The Alarm List  . . . . . . . . . . . . . . . . . . . . .  19
     6.5.  The Shelved Alarms List . . . . . . . . . . . . . . . . .  21
     6.6.  RPCs  . . . . . . . . . . . . . . . . . . . . . . . . . .  21
     6.7.  Notifications . . . . . . . . . . . . . . . . . . . . . .  21
   7.  Alarm YANG Module . . . . . . . . . . . . . . . . . . . . . .  21
   8.  X.733 Alarm Mapping Data Model  . . . . . . . . . . . . . . .  46
   9.  X.733 Alarm Mapping YANG Module . . . . . . . . . . . . . . .  46
   10. Security Considerations . . . . . . . . . . . . . . . . . . .  52
   11. Acknowledgements  . . . . . . . . . . . . . . . . . . . . . .  52
   12. References  . . . . . . . . . . . . . . . . . . . . . . . . .  53
     12.1.  Normative References . . . . . . . . . . . . . . . . . .  53
     12.2.  Informative References . . . . . . . . . . . . . . . . .  53
   Appendix A.  Enterprise-specific Alarm-Types Example  . . . . . .  54
Show full document text