Network Working Group                                          Y. Zhuang
Internet-Draft                                                   Z. Wang
Intended status: Informational                                    Huawei
Expires: December 30, 2015                                       D. King
                                                    Lancaster University
                                                                   Q. Wu
                                                                  Huawei
                                                               T. Taylor
                                                    PT Taylor Consulting
                                                           June 28, 2015

   Applicability of Generic YANG Data Model for layer Independent OAM
                               Management
           draft-zhuang-lime-yang-oam-model-applicability-00

Abstract

   A generic YANG data model for Operations, Administration, and
   Maintenance (OAM) has been defined in [GENYANGOAM], with the
   intention that technology-specific extensions will be developed to
   complete the implementation of the model.  In this document, we
   describe the applicability of the generic YANG OAM data model to
   specific OAM technologies.  To be concrete, we also demonstrate the
   usability and extensibility of the generic YANG OAM model with OAM
   protocols such as IP Ping, traceroute, and LSP Ping.

Status of This Memo

   This Internet-Draft is submitted in full conformance with the
   provisions of BCP 78 and BCP 79.

   Internet-Drafts are working documents of the Internet Engineering
   Task Force (IETF).  Note that other groups may also distribute
   working documents as Internet-Drafts.  The list of current Internet-
   Drafts is at http://datatracker.ietf.org/drafts/current/.

   Internet-Drafts are draft documents valid for a maximum of six months
   and may be updated, replaced, or obsoleted by other documents at any
   time.  It is inappropriate to use Internet-Drafts as reference
   material or to cite them other than as "work in progress."

   This Internet-Draft will expire on December 30, 2015.

Zhuang, et al.          Expires December 30, 2015               [Page 1]
Internet-Draft      Applicability of LIME Base Model           June 2015

Copyright Notice

   Copyright (c) 2015 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (http://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.  Code Components extracted from this document must
   include Simplified BSD License text as described in Section 4.e of
   the Trust Legal Provisions and are provided without warranty as
   described in the Simplified BSD License.

Table of Contents

   1.  Introduction  . . . . . . . . . . . . . . . . . . . . . . . .   3
   2.  Conventions Used In This Document . . . . . . . . . . . . . .   3
     2.1.  Terminology . . . . . . . . . . . . . . . . . . . . . . .   4
   3.  Basic Structure of Generic YANG Model for OAM . . . . . . . .   4
   4.  Guidelines For Extending the LIME Base Data Model . . . . . .   6
     4.1.  Importing the Base Model Into the Technology-Specific OAM
           Model . . . . . . . . . . . . . . . . . . . . . . . . . .   7
     4.2.  Using "augment" to Insert Additional Data Into the Base
           Model . . . . . . . . . . . . . . . . . . . . . . . . . .   7
     4.3.  Using "identity" and "identityref" to Identify New
           Technology Types  . . . . . . . . . . . . . . . . . . . .   8
     4.4.  Using the Choice and Case Nodes . . . . . . . . . . . . .  10
     4.5.  Define New RPCs and Notifications . . . . . . . . . . . .  11
   5.  Applicability of LIME Model to Various Technologies . . . . .  12
     5.1.  IP OAM  . . . . . . . . . . . . . . . . . . . . . . . . .  12
       5.1.1.  Technology Type Extension . . . . . . . . . . . . . .  12
       5.1.2.  MEP Configuration Extension . . . . . . . . . . . . .  12
       5.1.3.  Connectivity-Context Extension  . . . . . . . . . . .  13
       5.1.4.  RPC Extension . . . . . . . . . . . . . . . . . . . .  13
       5.1.5.  ECMP extension  . . . . . . . . . . . . . . . . . . .  13
     5.2.  IPPM (IP Performance Measurement) . . . . . . . . . . . .  13
       5.2.1.  MEP Configuration Extension . . . . . . . . . . . . .  14
       5.2.2.  RPC Extension . . . . . . . . . . . . . . . . . . . .  14
     5.3.  Ethernet OAM  . . . . . . . . . . . . . . . . . . . . . .  14
       5.3.1.  Technology Type Extension . . . . . . . . . . . . . .  14
       5.3.2.  MEP Configuration Extension . . . . . . . . . . . . .  15
       5.3.3.  Connectivity-Context Extension  . . . . . . . . . . .  15
       5.3.4.  RPC Extension . . . . . . . . . . . . . . . . . . . .  15
       5.3.5.  ECMP Extension  . . . . . . . . . . . . . . . . . . .  15
       5.3.6.  Relation with Service OAM FM Modules  . . . . . . . .  16
     5.4.  TRILL OAM . . . . . . . . . . . . . . . . . . . . . . . .  16

Zhuang, et al.          Expires December 30, 2015               [Page 2]
Internet-Draft      Applicability of LIME Base Model           June 2015

       5.4.1.  Technology Type Extension . . . . . . . . . . . . . .  16
       5.4.2.  MEP Configuration Extension . . . . . . . . . . . . .  16
       5.4.3.  Connectivity-Context Extension  . . . . . . . . . . .  16
       5.4.4.  RPC Extension . . . . . . . . . . . . . . . . . . . .  17
       5.4.5.  ECMP Extension  . . . . . . . . . . . . . . . . . . .  18
       5.4.6.  Performance Management (PM) Extension . . . . . . . .  19
       5.4.7.  Usage example . . . . . . . . . . . . . . . . . . . .  19
     5.5.  NVO3 OAM  . . . . . . . . . . . . . . . . . . . . . . . .  23
       5.5.1.  Technology Type Extension . . . . . . . . . . . . . .  23
       5.5.2.  Sub Technology Type Extension . . . . . . . . . . . .  23
       5.5.3.  MEP Configuration Extension . . . . . . . . . . . . .  24
       5.5.4.  Connectivity-Context Extension  . . . . . . . . . . .  24
       5.5.5.  RPC Extension . . . . . . . . . . . . . . . . . . . .  25
       5.5.6.  ECMP Extension  . . . . . . . . . . . . . . . . . . .  25
     5.6.  MPLS OAM  . . . . . . . . . . . . . . . . . . . . . . . .  25
       5.6.1.  Technology Type Extension . . . . . . . . . . . . . .  25
       5.6.2.  MEP Configuration Extension . . . . . . . . . . . . .  25
       5.6.3.  Connectivity-Context Extension  . . . . . . . . . . .  26
       5.6.4.  ECMP Extension  . . . . . . . . . . . . . . . . . . .  26
       5.6.5.  Usage Example . . . . . . . . . . . . . . . . . . . .  26
   6.  Open Issues . . . . . . . . . . . . . . . . . . . . . . . . .  27
   7.  Security Considerations . . . . . . . . . . . . . . . . . . .  28
   8.  IANA Considerations . . . . . . . . . . . . . . . . . . . . .  28
   9.  References  . . . . . . . . . . . . . . . . . . . . . . . . .  28
     9.1.  Normative References  . . . . . . . . . . . . . . . . . .  28
     9.2.  Informative References  . . . . . . . . . . . . . . . . .  28
   Authors' Addresses  . . . . . . . . . . . . . . . . . . . . . . .  29

1.  Introduction

   The YANG [RFC6020] over NETCONF [RFC6241] data model for Layer
   independent OAM Management defined in [GENYANGOAM] provides
   consistent configuration, reporting and representation of OAM
   mechanisms at any layer for any technology.

   This draft describes the applicability of the generic YANG OAM model
   to various transport technologies and demonstrates that the YANG
   model(s) in the LIME WG are usable and extensible for those
   technologies.  The demonstration uses IP, Ethernet, NVO3, TRILL, and
   MPLS as specific examples.

2.  Conventions Used In This Document

   This document contains no normative language.

Zhuang, et al.          Expires December 30, 2015               [Page 3]
Internet-Draft      Applicability of LIME Base Model           June 2015

2.1.  Terminology

   MP Maintenance Point [IEEE802.1Q].

   MEP  Maintenance association End Point [RFC7174] [IEEE802.1Q]
      [RFC6371].

   MIP  Maintenance domain Intermediate Point [RFC7174] [IEEE802.1Q]
      [RFC6371].

   MA Maintenance Association [IEEE802.1Q] [RFC7174].

   MD Maintenance Domain [IEEE802.1Q].

   OAM  Operations, Administration, and Maintenance [RFC6291].

   TRILL  Transparent Interconnection of Lots of Links [RFC6325].

3.  Basic Structure of Generic YANG Model for OAM

   As the basis of this document, the generic YANG model for OAM
   specified as the LIME base model is shown in Figure 1.

Zhuang, et al.          Expires December 30, 2015               [Page 4]
Internet-Draft      Applicability of LIME Base Model           June 2015

   module: ietf-gen-oam
         +--rw domains
            +--rw domain* [technology MD-name-string]
               +--rw technology        identityref
               +--rw MD-name-string    MD-name-string
               ...
               +--rw MAs
                  +--rw MA* [MA-name-string]
                     +--rw MA-name-string       MA-name-string
                     ...
                     +--rw MEP* [mep-name]
                     |  +--rw mep-name             MEP-name
                     |  ...
                     |  +--rw session* [session-cookie]
                     |  ...
                     +--rw MIP* [interface]
                     |  +--rw interface    if:interface-ref
                     +--rw related-oam-layer* [offset]
                        ...
      rpcs:
         +---x continuity-check
         |     ...
         +---x continuity-verification     {connectivity-verification}?
         |     ...
         +---x path-discovery
            ...
      notifications:
         +---n defect-condition-notification
            ...

            Figure 1: Structure of the Generic LIME Base Model

   The generic YANG OAM model comprises three definitions for
   configuration and operational state data:

   o  configuration model definition;

   o  Remote procedure call (RPC) definition;

   o  and notification definition.

   The configuration model definition provides hierarchical structure to
   describe fault domain (i.e., maintainence domain), test point (i.e.,
   maintainence point), technology type, layering, and session context
   for trouble-shooting.  This basic configuration model enables users
   to select corresponding layers and nodes serving as anchor points to
   define their specific technology OAM YANG models.

Zhuang, et al.          Expires December 30, 2015               [Page 5]
Internet-Draft      Applicability of LIME Base Model           June 2015

   The RPC definition provides uniform APIs for common OAM functions
   such as continuity check, connectivity verification, path discovery,
   performance measurement and their equivalents.  These APIs are used
   by the network management system (NMS) to control and manipulate OAM
   tools and functionalities on network elements for measuring and
   monitoring the data plane (e.g., LSP Ping, IP performance measurement
   protocol).  These OAM tools can be activated on a continual basis or
   manually to detect a specific anomaly.

   The notification definition also provides a uniform API to report
   defects, faults, and network failures at different layers.  This API
   is used by network elements to report to the network management
   system (NMS).  The content of each notification includes the fault
   domain and the test point(s) that detected the fault and generated
   the error message.  This API must be activated on a continual basis.

4.  Guidelines For Extending the LIME Base Data Model

   As described in Section 3, the LIME base model provides a
   hierarchical structure for configuration, notification and RPCs.
   Each of these three aspects should be extended with technology-
   specific features and parameters relating to each technology of
   interest.

   YANG allows a module to insert additional nodes into data models,
   including both the current module (and its submodules) or an external
   module.  This is useful to let specific technologies add specific
   parameters into the LIME base model.

   Here we summarize five steps to extend the LIME base model for
   specific technologies:

   1.  Import the base model in the technology specific OAM model to
       reuse the structure defined in the base model.

   2.  Use "augment" to insert additional data into the base model
       (e.g., in the MEP) to specify extensions for the specific
       technology.

   3.  Use the "identity" and "identityref" constructs (instead of
       "enum") to identify new technology types.

   4.  Use "choice" and "case" nodes instead of "typedef".

   5.  Use "feature" to define optional functionality within the data
       model.

Zhuang, et al.          Expires December 30, 2015               [Page 6]
Internet-Draft      Applicability of LIME Base Model           June 2015

   6.  Define new RPCs and notifications in the technology specific OAM
       data model.

4.1.  Importing the Base Model Into the Technology-Specific OAM Model

   YANG allows a module to reference external modules to reuse data
   already defined in those modules.  Therefore a technology-specific
   model can import data from the LIME base model.

   The import statements are used to make definitions available inside
   other modules [RFC6020].  Users who want to develop a technology-
   specific OAM model should import the ietf-gen-oam YANG model with the
   following statements:

   module ietf-xxx-oam {
           namespace "urn:foo:params:xml:ns:yang:ietf-xxx-oam";
           prefix xxxoam;

           import ietf-gen-oam {
             prefix goam;
           }
           ......

4.2.  Using "augment" to Insert Additional Data Into the Base Model

   As described in [RFC6020], the "augment" statement defines the
   location in the data model hierarchy where new nodes are inserted.
   By using the "augment" statement, the hierarchy of the LIME base
   model can be extended with new data nodes that express technology-
   pecific parameters to meet the requirements of the respective
   technologies.

   The technology-specific model developer must take care to select the
   right layers and nodes in the LIME base model as anchor points to
   insert these additional data.  For example, assume a technology-
   specific OAM YANG model A.  An "a" node needs to be inserted within
   the MA (Maintenance Association):

Zhuang, et al.          Expires December 30, 2015               [Page 7]
Internet-Draft      Applicability of LIME Base Model           June 2015

   augment /goam:domains/goam:domain/goam:MAs/goam:MA:
             +--a?   foo

   Corresponding YANG encoding:

   augment "/goam:domains/goam:domain/goam:MAs/goam:MA"{
            leaf a{
             type foo
              description
              "foo";
    }
   }

4.3.  Using "identity" and "identityref" to Identify New Technology
      Types

   [GENYANGOAM] uses the "identity" statement to define a new globally
   unique, abstract, and untyped "technology-types" base identity.  As
   described below, each technology-specific module specifies a
   corresponding concrete identity using this base: ipv4, ipv6, vpls,
   nvo3, TRILL, mpls, etc.  [GENYANGOAM] itself defines the ipv4 and
   ipv6 identities.

   [GENYANGOAM] also defines a "command-sub-type" abstract identity for
   different RPC commands, e.g., to distinguish the types of IP ping
   [RFC792], LSP ping [RFC4379], TRILL OAM [TRILLOAMYANG].  Use of this
   identity is optional for most cases.

   The corresponding statements are shown as below.

Zhuang, et al.          Expires December 30, 2015               [Page 8]
Internet-Draft      Applicability of LIME Base Model           June 2015

     identity technology-types {
       description
         "this is the base identity of technology types such as
          vpls, nvo3, TRILL, ipv4, ipv6, mpls, etc";
     }

     identity ipv4 {
       base technology-types;
       description
         "technology of ipv4";
     }

     identity ipv6 {
       base technology-types;
       description
         "technology of ipv6";
     }

     identity command-sub-type {
       description
         "defines different rpc command subtypes, e.g rfc792 IP
          ping, rfc4379 LSP ping, TRILLOAMYANG trill OAM, this is
          optional for most cases";
     }

     identity icmp-rfc792 {
       base command-sub-type;
       description
         "Defines the command subtypes for ICMP ping";
       reference "RFC 792";
     }

   With the base identity of technology types and command-sub-type,
   ietf-gen-oam YANG model users who want to develop a specific OAM
   technology model can define their own technology-types and/or
   command-sub-type identity.

   For example, if we want to define a specific OAM technology YANG
   model A, we could define a corresponding technology-types by using
   following statements:

          identity A {
             base goam:technology-types;
             description
               "Technology A";
           }

Zhuang, et al.          Expires December 30, 2015               [Page 9]
Internet-Draft      Applicability of LIME Base Model           June 2015

   With this definition of a technology type A, the technology "leaf"
   under the domains list can reference this new type.

4.4.  Using the Choice and Case Nodes

   YANG allows the data model to segregate incompatible nodes into
   distinct choices using the "choice" and "case" statements.  The
   "choice" statement contains a set of "case" statements that define
   sets of schema nodes that cannot appear together.  Each "case" may
   contain multiple nodes, but each node may appear in only one "case"
   under a "choice".  Note that when an element from one case is
   created, all elements from all other cases are implicitly deleted
   [RFC6020].

   In order to support flexible augment, ietf-gen-oam defined a set of
   choice and case nodes to serve as anchor points for specific OAM
   technologies.  Note that the default values of these nodes -- MD-
   name, MA-name, connectivity-context, flow-entropy, et cetera -- are
   empty.

   For example:

               +--rw MAs
                  +--rw MA* [MA-name-string]
                     ...
                     +--rw (connectivity-context)?
                     |  +--:(context-null)
                     |     +--rw context-null?        Empty

   Corresponding YANG encoding:

       choice connectivity-context {
         default "context-null";
         case context-null {
           description
             "this is a place holder when no context is needed";
           leaf context-null {
             type empty;
             description
               "there is no context defined";
           }
         }
         description
           "connectivity context";
       }

Zhuang, et al.          Expires December 30, 2015              [Page 10]
Internet-Draft      Applicability of LIME Base Model           June 2015

   ietf-gen-oam YANG model users who want to define a specific OAM
   technology model can augment the corresponding choice node by
   defining a new case to carry technology specific extensions.

   For example, for a specific OAM technology YANG model A, an "a" node
   is needed to indicate the connectivity context for this specific OAM
   technology.  To achieve this, it is only necessary to augment the
   connectivity-context choice node in the ietf-gen-OAM YANG model by
   defining a "connectivity-context-A" case as:

   augment /goam:domains/goam:domain/goam:MAs/goam:MA
   /goam:connectivity-context:
         +--:(connectivity-context-A)
            +--a?   foo

   Corresponding YANG encoding:

   augment "/goam:domains/goam:domain/goam:MAs/goam:MA"
   +"/goam:connectivity-context" {
      case connectivity-context-A {
       leaf a{
        type foo;}
       }
      }

4.5.  Define New RPCs and Notifications

   The LIME base model presents three basic RPCs: continuity check,
   connectivity verification and path discovery.  Technology-specific
   OAM models can either extend the existing RPCs and notifications
   defined in the LIME base model or define new RPCs and notifications
   if generic RPCs and notifications cannot be reused to meet their
   requirements.

   For example, a Multicast Tree Verification (MTV) [TRILLOAMYANG] RPC
   command is defined in the TRILL OAM model to verify connectivity as
   well as data-plane and control-plane integrity of TRILL multicast
   forwarding as follows:

Zhuang, et al.          Expires December 30, 2015              [Page 11]
Internet-Draft      Applicability of LIME Base Model           June 2015

      rpcs:
         +---x mtv
            +--ro input
            |  +--ro technology             identityref
            |  +--ro MD-name-string         MD-name-string
            |  +--ro MA-name-string?        MA-name-string
            |  ...
            +--ro output
               +--ro response* [mep-address mep-id]
                  +--ro hop-count?                  uint8
                  +--ro mep-id                      tril-rb-nickname
                  +--ro mep-address                 tril-rb-nickname
                  ...

5.  Applicability of LIME Model to Various Technologies

   As mentioned above, the ietf-gen-oam model describes the abstract
   common core configuration, statistics, RPCs, and notifications for
   layer independent OAM management.

   Following guidelines stated in Section 4, ietf-gen-oam YANG model
   users can augment this base model by defining and adding new data
   nodes with technology specific functions and parameters into proper
   anchor points of the ietf-gen-oam model, so as to develop a
   technology-specific OAM model.

   With these guidelines in hand, this section further demonstrates the
   usability of the ietf-gen-oam YANG model to various OAM technologies.
   Note that, in this section, we only present several snippets of
   technology-specific data model extensions for illustrative purposes.
   The complete model extensions should be worked on in respective
   protocol working groups.

5.1.  IP OAM

5.1.1.  Technology Type Extension

   The technology types ipv4 and ipv6 have already been defined in the
   LIME base model.  Therefore no technology type extension is required
   in the IP OAM model.

5.1.2.  MEP Configuration Extension

   MEP configuration in the LIME base model already supports configuring
   the interface on which the MEP is located with an IP address.  There
   is no additional MEP configuration extension needed for IP OAM.

Zhuang, et al.          Expires December 30, 2015              [Page 12]
Internet-Draft      Applicability of LIME Base Model           June 2015

   However, IP Ping, traceroute and session monitoring do not use the
   MEPID in their message headers.  Therefore it is important to have
   method to derive the MEPID in an automatic manner with no user
   intervention.

5.1.3.  Connectivity-Context Extension

   In IP OAM, the connectivity-context is a 12 bit VLAN ID.  The LIME
   base model defines a placeholder for connectivity-context.  This
   allows other technologies to easily augment it to include technology
   specific extensions.  The snippet below depicts an example of
   augmenting context-id to include VLAN ID.

   augment /goam:domains/goam:domain/goam:MAs/goam:MA
   /goam:MEP/goam:connectivity-context:
      +--:(context-id-vlan)
         +--rw context-id-vlan?   vlan
   augment /goam:domains/goam:domain/goam:MAs/goam:MA/goam:MEP
   /goam:session/goam:connectivity-context:
      +--:(context-id-vlan)
         +--rw context-id-vlan?   vlan

5.1.4.  RPC Extension

   Technology type in the RPC definition has already been defined in the
   LIME OAM base model.  Therefore no technology type extension is
   required in the RPC definition.  For IP OAM, IP Ping and IP
   Traceroute RPCs need to be supported.  For the IP OAM model, the
   continuity-check RPC with IPv4 or IPv6 as technology type can be
   mapped to the IP Ping RPC, while the path-discovery RPC with IPv4 or
   IPv6 as technology type can be mapped to IP Traceroute.

5.1.5.  ECMP extension

   The flow-entropy parameter in the LIME OAM configuration model is an
   optional parameter.  Since standard IP OAM protocols, e.g., IP Ping
   and Traceroute, don't support ECMP path selection, the flow-entropy
   parameter does not need to be supported in the IP OAM model.

5.2.  IPPM (IP Performance Measurement)

   Editor Note: IP performance measurement (PM) and IP Ping and
   Traceroute are discussed separately based on the [RFC7276]
   classification of OAM technologies.  Although IPPM and IP OAM are
   both applied to the IP network, based on Table 4 of [RFC7276], IP OAM
   does not support performance measurement.  It is necessary to use
   OWAMP and TWAMP, defined in IPPM, for that purpose.

Zhuang, et al.          Expires December 30, 2015              [Page 13]
Internet-Draft      Applicability of LIME Base Model           June 2015

5.2.1.  MEP Configuration Extension

   To support IP performance measurement, MEP configuration in the LIME
   base model needs to be extended with:

   o  loss-stats-group: grouping object for loss measurement session
      statistics.

   o  measurement-timing-group: grouping object used for proactive and
      on-demand scheduling of PM measurement sessions.

   o  delay-measurement-configuration-group: grouping configuration
      object for the delay measurement function.

   o  delay-measurement-stats-group: grouping object for elay
      measurement session statistics.

5.2.2.  RPC Extension

   To support IP performance measurement, four RPCs need to be defined
   in the IPPM model:

   o  create-loss-measurement RPC: allows scheduling of one-way or two-
      way on-demand or proactive performance monitoring loss measurement
      sessions.

   o  abort-loss-measurement RPC: allows aborting of currently running
      or scheduled loss measurement session.

   o  create-delay-measurement RPC: allows scheduling of one-way or two-
      way on-demand or proactive performance monitoring delay
      measurement sessions.

   o  abort-delay-measurement RPC: allows aborting of currently running
      or scheduled delay measurement sessions.

5.3.  Ethernet OAM

5.3.1.  Technology Type Extension

   No Ethernet technology type is defined in the LIME base model.
   Therefore a technology type extension for Ethernet technology is
   required in the Ethernet OAM model as follows:

Zhuang, et al.          Expires December 30, 2015              [Page 14]
Internet-Draft      Applicability of LIME Base Model           June 2015

   identity ethernet {
       base technology-types;
       description
         "ethernet technology";
     }

5.3.2.  MEP Configuration Extension

   MEP configuration definition in the LIME base model already supports
   configuring the interface on which MEP is located with MAC address.
   No additional MEP configuration extension is required.

5.3.3.  Connectivity-Context Extension

   In Ethernet OAM, the connectivity-context is a 12 bit VLAN ID.  The
   LIME base model defines a placeholder for context-id.  This allows
   other technologies to easily augment that to include technology
   specific extensions.  The snippet below depicts an example of
   augmenting context-id to include VLAN ID.

   augment /goam:domains/goam:domain/goam:MAs
   /goam:MA/goam:MEP/goam:connectivity-context:
      +--:(context-id-vlan)
         +--rw context-id-vlan?   vlan
   augment /goam:domains/goam:domain/goam:MAs/goam:MA/goam:MEP
   /goam:session/goam:connectivity-context:
      +--:(context-id-vlan)
         +--rw context-id-vlan?   vlan

5.3.4.  RPC Extension

   Technology type in the RPC definition reuses the ethernet identity
   defined earlier.  For Ethernet OAM, Connectivity check, Loopback and
   linktrace RPCs need to be supported.  The connectivity-check RPC in
   the LIME base model with Ethernet as the technology type can be used
   to represent Ethernet connectivity check.  The base model
   connectivity-verification RPC with Ethernet as the technology type
   can be mapped to Ethernet loopback.  The base model path-discovery
   RPC with Ethernet as the technology type can be mapped to Ethernet
   linktrace.

5.3.5.  ECMP Extension

   The flow-entropy parameter in the LIME OAM configuration model is an
   optional parameter.  Standard Ethernet OAM protocols, i.e.,
   connectivity check, loopback and linktrace do not support ECMP path
   selection, so the flow-entropy parameter does not need to be
   supported in the Ethernet OAM model.

Zhuang, et al.          Expires December 30, 2015              [Page 15]
Internet-Draft      Applicability of LIME Base Model           June 2015

5.3.6.  Relation with Service OAM FM Modules

   Note that Service OAM Fault Management YANG Modules defined in [MEF-
   38] are one example of an Ethernet OAM model, but were developed
   before the LIME base model was proposed.  As a result, the Service
   OAM Fault Management YANG Modules defined in [MEF-38] are not
   compliant with LIME base model nor do they extend from LIME base
   model.

5.4.  TRILL OAM

5.4.1.  Technology Type Extension

   No TRILL technology type has been defined in the LIME base model.
   Therefore a technology type extension is required in the TRILL OAM
   model.  The technology type "trill" is defined as an identity that
   augments the base "technology-types" defined in the LIME base model:

   identity trill{
    base goam:technology-types;
    description
     "trill type";
   }

5.4.2.  MEP Configuration Extension

   The MEP configuration definition in the LIME base model already
   supports configuring the interface of MEP with either MAC address or
   IP address.  In addition, the MEP address can be represented using a
   2 octet RBridge Nickname in TRILL OAM . Hence, the TRILL OAM model
   augments the MEP configuration in base model to add a nickname case
   into the MEP address choice node as follows:

   augment /goam:domains/goam:domain/goam:MAs
   /goam:MA/ goam:MEP/goam:mep-address:
         +--:( mep-address-trill)
         |  +--rw mep-address-trill?  tril-rb-nickname

5.4.3.  Connectivity-Context Extension

   In TRILL OAM, connectivity-context is either a 12 bit VLAN ID or a 24
   bit Fine Grain Label.  The LIME base model defines a placeholder for
   context-id.  This allows other technologies to easily augment that to
   include technology specific extensions.  The snippet below depicts an
   example of augmenting connectivity-context to include either VLAN ID
   or Fine Grain Label.

Zhuang, et al.          Expires December 30, 2015              [Page 16]
Internet-Draft      Applicability of LIME Base Model           June 2015

   augment /goam:domains/goam:domain/goam:MAs
   /goam:MA /goam:connectivity-context:
         +--:(connectivity-context-vlan)
         |  +--rw connectivity-context-vlan?   vlan
         +--:(connectivity-context-fgl)
            +--rw connectivity-context-fgl?    fgl

   augment /goam:domains/goam:domain/goam:MAs/goam:MA/goam:MEP
   /goam:session/goam:connectivity-context:
         +--:(connectivity-context-vlan)
         |  +--rw connectivity-context-vlan?   vlan
         +--:(connectivity-context-fgl)
            +--rw connectivity-context-fgl?    fgl

5.4.4.  RPC Extension

   In the TRILL OAM YANG model, the continuity-check and path-discovery
   RPC commands are extended with TRILL specific requirements.  The
   snippet below illustrates the TRILL OAM RPC extension.

Zhuang, et al.          Expires December 30, 2015              [Page 17]
Internet-Draft      Applicability of LIME Base Model           June 2015

   augment /goam:continuity-check/goam:input:
         +--ro (out-of-band)?
         |  +--:(ipv4-address)
         |  |  +--ro ipv4-address?      inet:ipv4-address
         |  +--:(ipv6-address)
         |  |  +--ro ipv6-address?      inet:ipv6-address
         |  +--:(trill-nickname)
         |     +--ro trill-nickname?    tril-rb-nickname
         +--ro diagnostic-vlan?   boolean
   augment /goam:continuity-check/goam:input/goam:flow-entropy:
         +--:(flow-entropy-trill)
            +--ro flow-entropy-trill?   flow-entropy-trill
   augment /goam:continuity-check/goam:output:
         +--ro upstream-rbridge?   tril-rb-nickname
         +--ro next-hop-rbridge*   tril-rb-nickname
   augment /goam:path-discovery/goam:input:
         +--ro (out-of-band)?
         |  +--:(ipv4-address)
         |  |  +--ro ipv4-address?      inet:ipv4-address
         |  +--:(ipv6-address)
         |  |  +--ro ipv6-address?      inet:ipv6-address
         |  +--:(trill-nickname)
         |     +--ro trill-nickname?    tril-rb-nickname
         +--ro diagnostic-vlan?   boolean
   augment /goam:path-discovery/goam:input/goam:flow-entropy:
         +--:(flow-entropy-trill)
            +--ro flow-entropy-trill?   flow-entropy-trill
   augment /goam:path-discovery/goam:output/goam:response:
         +--ro upstream-rbridge?   tril-rb-nickname
         +--ro next-hop-rbridge*   tril-rb-nickname

5.4.5.  ECMP Extension

   The flow-entropy parameter in the LIME base model is an optional
   parameter.  Since TRILL supports ECMP path selection, flow-entropy in
   TRILL is defined as a 96 octet field.  The snippet below illustrates
   its extension.

   augment /goam:domains/goam:domain/goam:MAs/goam:MA/goam:MEP
   /goam:flow-entropy:
         +--:(flow-entropy-trill)
            +--rw flow-entropy-trill?   flow-entropy-trill
   augment /goam:domains/goam:domain/goam:MAs/goam:MA/goam:MEP
   /goam:session/goam:flow-entropy:
         +--:(flow-entropy-trill)
            +--rw flow-entropy-trill?   flow-entropy-trill

Zhuang, et al.          Expires December 30, 2015              [Page 18]
Internet-Draft      Applicability of LIME Base Model           June 2015

5.4.6.  Performance Management (PM) Extension

5.4.6.1.  MEP Configuration Extension

   To support performance measurement for TRILL, MEP configuration in
   the LIME base model needs to be extended with:

   o  loss-stats-group: grouping statistics object for TRILL Loss
      measurement sessions;

   o  measurement-timing-group: grouping object used for proactive and
      on-demand scheduling of PM measurement sessions;

   o  delay-measurement-configuration-group: grouping configuration
      object for TRILL delay measurement function;

   o  delay-measurement-stats-group: grouping statistics object for
      TRILL delay measurement sessions.

5.4.6.2.  RPC Extension

   To support performance measurement for TRILL, four new RPCs need to
   be defined in the TRILL OAM PM model:

   o  create-loss-measurement RPC: allows scheduling of one-way or two-
      way on-demand or proactive performance monitoring loss measurement
      sessions.

   o  abort-loss-measurement RPC: allows aborting of currently running
      or scheduled loss measurement sessions.

   o  create-delay-measurement RPC: allows scheduling of one-way or two-
      way on-demand or proactive performance monitoring delay
      measurement sessions.

   o  abort-delay-measurement RPC: allows aborting of currently running
      or scheduled delay measurement sessions.

5.4.7.  Usage example

   This part gives a simple example of implementing the TRILL OAM model
   onto network devices.

   The scenario is shown in Figure 2, in which there are two companies:
   A and B.  Both have departments in City 1 and City 2.  Meanwhile,
   different departments within the same company should be able to
   communicate with each other.  However, the communication services of
   these two companies should be segregated from each other.

Zhuang, et al.          Expires December 30, 2015              [Page 19]
Internet-Draft      Applicability of LIME Base Model           June 2015

   To meet the requirements above, two Ethernet Lease line, E-Line-1 and
   E-Line-2, are set between NE1 and NE3: to isolate the communication
   traffic between two companies.  VLAN 100 associates port 3-EFF8-1 of
   NE1 facing with company A while VLAN 200 associates port 3-EF8-2 of
   NE1 facing with company B.  For network maintenance, NE1, NE2 and NE3
   are within a same maintenance domain: MD1.  Two maintenance
   associations MA1 and MA2 are configured and stand for E-Line-1 and
   E-Line-2 under MD1.  The MAC addresses of NE1, NE2, NE3 are 00-1E-4C-
   84-22-F1, 00-1E-4C-84-22-F2, 00-1E-4C- 84-22-F3 respectively.

                   +------+       +-----+       +------+
                   |      |       |     |       |      |
                   |  NE1 +-------| NE2 |-------+  NE3 |
                   |      |       |     |       |      |
           +-------+--+---+       +-----+       +---+--+---------+
   3-EFF8-1|          |3-EFF8-2                     |            |
           |          |                             |            |
         +-+-+     +--++                          +-+-+        +-+-+
         |   |     |   |                          |   |        |   |
         +---+     +---+                          +---+        +---+
          A          B                              A            B
              CITY1                                      CITY2

                       Figure 2: TRILL OAM scenario

5.4.7.1.  Ethernet OAM Extension

   To fulfill the Ethernet OAM configuration, the lIME base model should
   be extended by augmenting the connectivity-context and inserting a
   port node in the MEP list.  The snippet below illustrates the
   Ethernet OAM model extension.

   augment /goam:domains/goam:domain/goam:MAs
   /goam:MA/goam:MEP /goam:mep-address:
         +--:( mep-address-trill)
         |  +--rw mep-address-trill?  tril-rb-nickname
   augment /goam:domains/goam:domain/goam:MAs/goam:MA
   /goam:connectivity-context:
         +--:(connectivity-context-vlan)
         |  +--rw connectivity-context-vlan?   vlan
         +--:(connectivity-context-fgl)
            +--rw connectivity-context-fgl?    fgl

   augment /goam:domains/goam:domain/goam:MAs/goam:MA/goam:MEP
   /goam:session/goam:connectivity-context:
         +--:(connectivity-context-vlan)
         |  +--rw connectivity-context-vlan?   vlan
         +--:(connectivity-context-fgl)

Zhuang, et al.          Expires December 30, 2015              [Page 20]
Internet-Draft      Applicability of LIME Base Model           June 2015

            +--rw connectivity-context-fgl?    fgl
   augment /goam:domains/goam:domain/goam:MAs/goam:MA
   /goam:MEP/goam:flow-entropy:
         +--:(flow-entropy-trill)
            +--rw flow-entropy-trill?   flow-entropy-trill
   augment /goam:domains/goam:domain/goam:MAs/goam:MA/goam:MEP
   /goam:session/goam:flow-entropy:
         +--:(flow-entropy-trill)
            +--rw flow-entropy-trill?   flow-entropy-trill
   augment /goam:continuity-check/goam:input:
         +--ro (out-of-band)?
         |  +--:(ipv4-address)
         |  |  +--ro ipv4-address?      inet:ipv4-address
         |  +--:(ipv6-address)
         |  |  +--ro ipv6-address?      inet:ipv6-address
         |  +--:(trill-nickname)
         |     +--ro trill-nickname?    tril-rb-nickname
         +--ro diagnostic-vlan?   boolean
   augment /goam:continuity-check/goam:input/goam:flow-entropy:
         +--:(flow-entropy-trill)
            +--ro flow-entropy-trill?   flow-entropy-trill
   augment /goam:continuity-check/goam:output:
         +--ro upstream-rbridge?   tril-rb-nickname
         +--ro next-hop-rbridge*   tril-rb-nickname
   augment /goam:path-discovery/goam:input:
         +--ro (out-of-band)?
         |  +--:(ipv4-address)
         |  |  +--ro ipv4-address?      inet:ipv4-address
         |  +--:(ipv6-address)
         |  |  +--ro ipv6-address?      inet:ipv6-address
         |  +--:(trill-nickname)
         |     +--ro trill-nickname?    tril-rb-nickname
         +--ro diagnostic-vlan?   boolean
   augment /goam:path-discovery/goam:input/goam:flow-entropy:
         +--:(flow-entropy-trill)
            +--ro flow-entropy-trill?   flow-entropy-trill
   augment /goam:path-discovery/goam:output/goam:response:
         +--ro upstream-rbridge?   tril-rb-nickname
         +--ro next-hop-rbridge*   tril-rb-nickname

5.4.7.2.  Corresponding XML Instance Example

   This section gives an example of the corresponding XML instance for
   devices to implement the example Ethernet OAM data models in
   Section 5.4.7.1.

      <domains>
       <domains>

Zhuang, et al.          Expires December 30, 2015              [Page 21]
Internet-Draft      Applicability of LIME Base Model           June 2015

        <technology> ethernet </techonlogy>
        <MD-name-string> MD1 </MD-name-string>
        <MAs>
         <MA>
          <MA-name-string>MA1</MA-name-string>
          <connectivity-context>
           <connectivity-context-vlan>
            100
           </connectivity-context-vlan>
          </connectivity-context>
          <MEP>
           <mep-name>NE1</mep-name>
           <mp-address>
            <mac-address>
             00-1E-4C-84-22-F1
            </mac-address>
           </mp-address>
          </MEP>
          <MEP>

           <mep-name>NE3</mep-name>
           <port>3-EFF8-1</port>
           <mp-address>
            <mac-address>
             00-1E-4C-84-22-F3
            </mac-address>
           </mp-address>
          </MEP>
          <MIP>NE2</MIP>
         </MA>
         <MA>
          <MA-name-string>MA2</MA-name-string>
          <connectivity-context>
           <connectivity-context-vlan>
            200
           </connectivity-context-vlan>
          </connectivity-context>
          <MEP>
           <mep-name>NE1</mep-name>
           <port>3-EFF8-2</port>
           <mp-address>
            <mac-address>
             00-1E-4C-84-22-F1
            </mac-address>
           </mp-address>
          </MEP>
          <MEP>
           <mep-name>NE3</mep-name>

Zhuang, et al.          Expires December 30, 2015              [Page 22]
Internet-Draft      Applicability of LIME Base Model           June 2015

           <port>3-EFF8-2</port>
           <mp-address>
            <mac-address>
             00-1E-4C-84-22-F3
            </mac-address>
           </mp-address>
          </MEP>
          <MIP>NE2</MIP>
         </MA>
        </MAs>
       </domains>
      </domains>

5.5.  NVO3 OAM

5.5.1.  Technology Type Extension

   No NVO3 technology type has been defined in the LIME base model.
   Therefore technology type extension is required in the NVO3 OAM
   model.  The technology type "nvo3" is defined as an identity that
   augments the base "technology-types" defined in the LIME base model:

      identity nvo3{
       base goam:technology-types;
       description
        "nvo3 type";
      }

5.5.2.  Sub Technology Type Extension

   In NVO3, since different overlay encapsulation types such as VxLAN,
   NVGRE can be employed, the "technology-sub-type" data node is defined
   and added into the LIME base model to further identify the overlay
   types within the NVO3 model.  Based on it, we also define a
   technology sub-type for VxLAN encapsulation.  NVGRE and GENEVE, sub-
   types can be defined in the same way.

Zhuang, et al.          Expires December 30, 2015              [Page 23]
Internet-Draft      Applicability of LIME Base Model           June 2015

   identity technology-sub-type {
             description
               "certain implementations such as nvo3 can have different
                encapsulation types such as vxlan, nvgre and so on.
                Instead of defining separate models for each
                encapsulation, we define a technology sub-type to
                further identify different encapsulations. Technology
                sub-type is associated at the MA level";
           }

        identity technology-sub-type-vxlan {
          base technology-sub-type;
          description
            "technology sub-type is vxlan";
        }
   augment "/goam:domains/goam:domain/goam:MAs/goam:MA" {
          leaf technology-sub-type {
            type identityref {
              base technology-sub-type;
            }
          }
        }

5.5.3.  MEP Configuration Extension

   In NVO3, the MEP address is either an IPv4 or IPV6 address.  In the
   LIME base model, MEP address is defined as an IP address and the same
   definition can be used for NVO3 with no further modification.

5.5.4.  Connectivity-Context Extension

   In NVO3 context-id is a 24 bit virtual network identifier (VNI).  The
   LIME base model defines a placeholder for context-id.  This allows
   other technologies to easily augment that to include technology
   specific extensions.  The snippet below depicts an example of
   augmenting context-id to include VNI.

   augment "/goam:domains/goam:domain/goam:MAs/goam:MA
   /goam:connectivity-context"
            {
               case connctivity-context-nvo3 {
                 leaf vni {
                   type vni;
                 }
               }
            }

Zhuang, et al.          Expires December 30, 2015              [Page 24]
Internet-Draft      Applicability of LIME Base Model           June 2015

5.5.5.  RPC Extension

   In the NVO3 OAM YANG model, the End-Station-Locator RPC command is
   defined.  This command locates an end-station within the NVO3
   deployment.  [PTT -- what other tools are applicable??? Presumably
   one can use ICMP Ping, LSP Ping for CV, and the PM extensions, per
   RFC 7276 Table 4.]

5.5.6.  ECMP Extension

   In NVO3, flow-entropy depends on the technology sub-type, e.g.,
   VxLAN.  Technology sub-type is used to extend the base model to
   specific usage.  The snippet below illustrates the extension for
   VxLAN.

   augment "/goam:domains/goam:domain/goam:MAs/goam:MA
   /goam:flow-entropy" {
          case flow-entropy-vxlan {
            leaf flags-vxlan {
              type flags-vxlan;
            }
            leaf flow-entropy-vxlan {
              type flow-entropy-vxlan;
            }
          }
        }

5.6.  MPLS OAM

5.6.1.  Technology Type Extension

   No MPLS technology type has been defined in the LIME base model,
   hence it is required in the MPLS OAM model.  The technology type
   "mpls" is defined as an identity that augments the base "technology-
   types" defined in the LIME base model:

      identity mpls{
       base goam:technology-types;
       description
        "mpls type";
      }

5.6.2.  MEP Configuration Extension

   In MPLS, the MEP address is either an IPv4 or IPV6 address .  MEP-ID
   is either a 2 octet unsigned integer value or a variable length label
   value.  In the LIME base model, MEP-ID is defined as a variable

Zhuang, et al.          Expires December 30, 2015              [Page 25]
Internet-Draft      Applicability of LIME Base Model           June 2015

   length label value and the same definition can be used for MPLS with
   no further modification.

5.6.3.  Connectivity-Context Extension

   In MPLS context-id is a 24 bit MPLS label.  The LIME base model
   defines a placeholder for context-id.  This allows other technologies
   to easily augment that to include technology specific extensions.
   The snippet below depicts an example of augmenting context-id to
   include per VRF MPLS labels in IP VPN or per CE-PE MPLS labels in IP
   VPN.

   augment "/goam:domains/goam:domain/goam:MAs/goam:MA
   /goam:connectivity-context"
            {
              case connectivity-context-mpls {
                 leaf vrf-label {
                   type vrf-label;
                 }
               }
            }

5.6.4.  ECMP Extension

   Since MPLS supports ECMP path selection, the flow-entropy should be
   defined in MPLS OAM model.  Technology type is used to extend the
   YANG model to specific usage.

   augment "/goam:domains/goam:domain/goam:MAs/goam:MA
   /goam:flow-entropy" {
          case flow-entropy-mpls {
            leaf flags-mpls {
              type flags-mpls;
            }
            leaf flow-entropy-mpls{
              type flow-entropy-mpls;
            }
          }
        }

5.6.5.  Usage Example

   In the MPLS tunnel scenario (see Figure 3): tunnel_1 is a static LSP
   tunnel passing through NE1-NE2-NE4.  It is used to perform LSP PING.
   tunnel_3 is another static LSP tunnel passing through NE4-NE2-NE1,
   used to bring back the LSP PING result.  tunnel_2 is a third static
   LSP tunnel passing through NE1-NE3-NE4, used to perform LSP

Zhuang, et al.          Expires December 30, 2015              [Page 26]
Internet-Draft      Applicability of LIME Base Model           June 2015

   Traceroute. tunnel_4 is a fourth static LSP tunnel passing through
   NE4-NE3-NE1, used to bring back the LSP Traceroute result.

                                 +-------+
                                 |       |
                +--------------->+  NE2  +----------------+
                | ...............|       |<.............. |
                | .              +-------+              . |
                | .                                     . |
                | v                                     . v
            +---+---+                                 +---+---+
            |       |                                 |       |
            |  NE1  |                                 |  NE4  |
            |       |                                 |       |
            +---+---+                                 +---+--^+
             .  ^                                         |  .
             .  |                                         |  .
             .  |                +-------+                |  .
             .  |                |       |                |  .
             .  +----------------+  NE3  +<---------------+  .
             ....................|       |....................
                                 +-------+

        ----- forward direction LSP tunnel
        ......backward direction LSP tunnel

                        Figure 3: MPLS OAM scenario

5.6.5.1.  MPLS OAM Model Extension

   TBD.

5.6.5.2.  Corresponding XML Instance Example

   TBD.

6.  Open Issues

      Not all usage examples of technology-specific OAM model are
      specified.

      How technology specific OAM model is used to provide consistent
      configuration, reporting is not specified.

      How LIME based model is used to provide consistent configuration
      and reporting is not specified.

Zhuang, et al.          Expires December 30, 2015              [Page 27]
Internet-Draft      Applicability of LIME Base Model           June 2015

7.  Security Considerations

   TBD.

8.  IANA Considerations

   This document registers the following namespace URI in the IETF XML
   registry.

   URI:TBD

9.  References

9.1.  Normative References

   [GENYANGOAM]
              Senevirathne , T., Finn, N., Kumar, D., Salam, S., Wu, Q.,
              and Z. Wang, "Generic YANG Data Model for Operations,
              Administration, and Maintenance (OAM)", ID
              https://datatracker.ietf.org/doc/draft-tissa-lime-yang-
              oam-model/, June 2015.

   [IEEE802.1Q]
              "Media Access Control (MAC) Bridges and Virtual Bridged
              Local Area Networks", IEEE Std 802.1Q-2011, August 2011.

   [RFC6020]  Bjorklund, M., "YANG - A Data Modeling Language for the
              Network Configuration Protocol (NETCONF)", RFC 6020,
              October 2010.

   [RFC6241]  Enns, R., Bjorklund, M., Schoenwaelder, J., and A.
              Bierman, "Network Configuration Protocol (NETCONF)", June
              2011.

9.2.  Informative References

   [RFC4379]  Kompella, K. and G. Swallow, "Detecting Multi-Protocol
              Label Switched (MPLS) Data Plane Failures", RFC 4379,
              February 2006.

   [RFC6291]  Andersson, L., van Helvoort, H., Bonica, R., Romascanu,
              D., and S. Mansfield, "Guidelines for the Use of the "OAM"
              Acronym in the IETF", BCP 161, RFC 6291, June 2011.

   [RFC6325]  Perlman, R., Eastlake, D., Dutt, D., Gai, S., and A.
              Ghanwani, "Routing Bridges (RBridges): Base Protocol
              Specification", RFC 6325, July 2011.

Zhuang, et al.          Expires December 30, 2015              [Page 28]
Internet-Draft      Applicability of LIME Base Model           June 2015

   [RFC6371]  Busi, I. and D. Allan, "Operations, Administration, and
              Maintenance Framework for MPLS-Based Transport Networks",
              RFC 6371, September 2011.

   [RFC7174]  Salam, S., Senevirathne, T., Aldrin, S., and D. Eastlake,
              "Transparent Interconnection of Lots of Links (TRILL)
              Operations, Administration, and Maintenance (OAM)
              Framework", RFC 7174, May 2014.

   [RFC7276]  Mizrahi, T., Sprecher, N., Bellagamba, E., and Y.
              Weingarten, "An Overview of Operations, Administration,
              and Maintenance (OAM) Tools", RFC 7276, June 2014.

   [RFC792]   Postel, J., "Internet Control Message Protocol", RFC 792,
              September 1981.

   [TRILLOAMYANG]
              Kumar, D., Senevirathne, T., Finn, N., Salam, S., Xia, L.,
              and W. Hao, "YANG Data Model for TRILL Operations,
              Administration, and Maintenance (OAM) (Work in progress)",
              May 2015.

Authors' Addresses

   Yan Zhuang
   Huawei Technologies,Co.,Ltd
   101 Software Avenue, Yuhua District
   Nanjing  210012
   China

   Email: zhuangyan.zhuang@huawei.com

   Zitao Wang
   Huawei Technologies,Co.,Ltd
   101 Software Avenue, Yuhua District
   Nanjing  210012
   China

   Email: wangzitao@huawei.com

   Daniel King
   Lancaster University
   UK

   Email: daniel@olddog.co.uk

Zhuang, et al.          Expires December 30, 2015              [Page 29]
Internet-Draft      Applicability of LIME Base Model           June 2015

   Qin Wu
   Huawei
   101 Software Avenue, Yuhua District
   Nanjing, Jiangsu  210012
   China

   Email: bill.wu@huawei.com

   Tom Taylor
   PT Taylor Consulting
   Ottawa
   Canada

   Email: tom.taylor.stds@gmail.com

Zhuang, et al.          Expires December 30, 2015              [Page 30]