Network Working Group J. Quittek, Ed.
Internet-Draft R. Winter
Intended status: Informational T. Dietz
Expires: January 4, 2013 NEC Europe Ltd.
B. Claise
M. Chandramouli
Cisco Systems, Inc.
July 3, 2012
Requirements for Energy Management
draft-ietf-eman-requirements-07
Abstract
This document defines requirements for standards specifications for
energy management. The requirements defined in this document concern
monitoring functions as well as control functions. In detail, the
focus of the requirements is on the following features:
identification of powered entities, monitoring of their Power State,
power inlets, power outlets, actual power, power properties, received
energy, provided energy, and contained batteries. Further
requirements are included to enable control of powered entities'
power supply and Power State. This document does not specify the
features that must be implemented by compliant implementations but
rather features that must be supported by standards for energy
management.
Status of this Memo
This Internet-Draft is submitted in full conformance with the
provisions of BCP 78 and BCP 79.
Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF). Note that other groups may also distribute
working documents as Internet-Drafts. The list of current Internet-
Drafts is at http://datatracker.ietf.org/drafts/current/.
Internet-Drafts are draft documents valid for a maximum of six months
and may be updated, replaced, or obsoleted by other documents at any
time. It is inappropriate to use Internet-Drafts as reference
material or to cite them other than as "work in progress."
This Internet-Draft will expire on January 4, 2013.
Copyright Notice
Copyright (c) 2012 IETF Trust and the persons identified as the
Quittek, et al. Expires January 4, 2013 [Page 1]
Internet-Draft Requirements for Energy Management July 2012
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
the Trust Legal Provisions and are provided without warranty as
described in the Simplified BSD License.
Quittek, et al. Expires January 4, 2013 [Page 2]
Internet-Draft Requirements for Energy Management July 2012
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1. Conventional requirements for energy management . . . . . 6
1.2. Specific requirements for energy management . . . . . . . 6
2. Terminology . . . . . . . . . . . . . . . . . . . . . . . . . 7
3. General Considerations Related to Energy Management . . . . . 8
3.1. Power states . . . . . . . . . . . . . . . . . . . . . . . 8
3.2. Saving energy versus maintaining service level
agreements . . . . . . . . . . . . . . . . . . . . . . . . 9
3.3. Local versus network-wide energy management . . . . . . . 9
3.4. Energy monitoring versus energy saving . . . . . . . . . . 10
3.5. Overview of energy management requirements . . . . . . . . 10
4. Identification of Powered Entities . . . . . . . . . . . . . . 10
5. Information on Powered Entities . . . . . . . . . . . . . . . 11
5.1. General information on Powered Entities . . . . . . . . . 12
5.2. Power Interfaces . . . . . . . . . . . . . . . . . . . . . 13
5.3. Power . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.4. Power State . . . . . . . . . . . . . . . . . . . . . . . 16
5.5. Energy . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.6. Battery State . . . . . . . . . . . . . . . . . . . . . . 19
5.7. Time series of measured values . . . . . . . . . . . . . . 20
6. Control of Powered Entities . . . . . . . . . . . . . . . . . 21
7. Reporting on other Powered Entities . . . . . . . . . . . . . 22
8. Controlling Other Powered Entities . . . . . . . . . . . . . . 23
8.1. Controlling Power States of other Powered Entities . . . . 23
8.2. Controlling power supply . . . . . . . . . . . . . . . . . 24
9. Security Considerations . . . . . . . . . . . . . . . . . . . 24
10. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 25
11. Acknowledgements . . . . . . . . . . . . . . . . . . . . . . . 25
12. Informative References . . . . . . . . . . . . . . . . . . . . 25
Appendix A. Existing Standards . . . . . . . . . . . . . . . . . 27
A.1. Existing IETF Standards . . . . . . . . . . . . . . . . . 28
A.1.1. ENTITY MIB . . . . . . . . . . . . . . . . . . . . . . 28
A.1.2. ENTITY STATE MIB . . . . . . . . . . . . . . . . . . . 28
A.1.3. ENTITY SENSOR MIB . . . . . . . . . . . . . . . . . . 29
Quittek, et al. Expires January 4, 2013 [Page 3]
Internet-Draft Requirements for Energy Management July 2012
A.1.4. UPS MIB . . . . . . . . . . . . . . . . . . . . . . . 29
A.1.5. POWER ETHERNET MIB . . . . . . . . . . . . . . . . . . 30
A.1.6. LLDP MED MIB . . . . . . . . . . . . . . . . . . . . . 30
A.2. Existing standards of other bodies . . . . . . . . . . . . 30
A.2.1. DMTF . . . . . . . . . . . . . . . . . . . . . . . . . 30
A.2.2. OVDA . . . . . . . . . . . . . . . . . . . . . . . . . 31
A.2.3. IEEE-ISTO Printer WG . . . . . . . . . . . . . . . . . 31
Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . . . 31
Quittek, et al. Expires January 4, 2013 [Page 4]
Internet-Draft Requirements for Energy Management July 2012
1. Introduction
With rising energy cost and with an increasing awareness of the
ecological impact of running IT equipment, energy management
functions and interfaces are becoming an additional basic requirement
for network management systems and devices connected to a network.
This document defines requirements for standards specifications for
energy management, both monitoring functions and control functions.
In detail, the requirements listed are focused on the following
features: identification of Powered Entities , monitoring of their
Power State, power inlets, power outlets, actual power, power
properties, received energy, provided energy, and contained
batteries. Further included is control of Powered Entities ' power
supply and Power State.
The main subject of energy management are devices and their
components that receive and provide electric energy. Devices may
have an IP address, such as hosts, routers, and middleboxes, or they
are connected indirectly to the Internet via a proxy with an IP
address providing a management interface for the device. An example
are devices in a building infrastructure using non-IP protocols and a
gateway to the Internet.
These requirements concern the standards specification process and
not the implementation of specified standards. All requirements in
this document must be reflected by standards specifications to be
developed. However, which of the features specified by these
standards will be mandatory, recommended, or optional for compliant
implementations is to be defined by standards track document(s) and
not in this document.
Section 3 elaborates a set of general needs for energy management.
Requirements for an energy management standard are specified in
Sections 4 to 8.
Sections 4 to 6 contain conventional requirements specifying
information on Powered Entities and control functions.
Sections 7 and 8 contain requirements specific to energy management.
Due to the nature of power supply, some monitoring and control
functions are not conducted by interacting with the Powered Entity of
interest, but with other entities, for example, entities upstream in
a power distribution tree.
Quittek, et al. Expires January 4, 2013 [Page 5]
Internet-Draft Requirements for Energy Management July 2012
1.1. Conventional requirements for energy management
The specification of requirements for an energy management standard
starts with Section 4 addressing the identification of Powered
Entities and the granularity of reporting of energy-related
information. A standard must support unique identification of
powered entities, reporting per entire powered device, and reporting
energy-related information on individual components of a device or
subtended devices.
Section 5 specifies requirements related to monitoring of Powered
Entities . This includes general (type, context) information and
specific information on Power States, power inlets, power outlets,
power, energy, and batteries. Control Power State and power supply
of Powered Entities is covered by requirements specified in
Section 6.
1.2. Specific requirements for energy management
While the conventional requirements summarized above seem to be all
that would be needed for energy management, there are significant
differences between energy management and most well known network
management functions. The most significant difference is the need
for some devices to report on other entities. There are three major
reasons for this.
o For monitoring a particular Powered Entity it is not always
sufficient to communicate with the Powered Entity only. When the
Powered Entity has no instrumentation for determining power, it
might still be possible to obtain power values for the entity by
communication with other entities in its power distribution tree.
A simple example is retrieving power values from a power meter at
the power line into the Powered Entity. Common examples are a
Power Distribution Unit (PDU) and a Power over Ethernet (PoE)
switch. Both supply power to other entities at sockets or ports,
respectively, and are often instrumented to measure power per
socket or port.
o Similar considerations apply to controlling power supply of a
Powered Entity which often needs direct or indirect communications
with another entity upstream in the power distribution tree.
Again, a PDU and a PoE switch are common examples, if they have
the capability to switch on or off power at their sockets or
ports, respectively.
o Energy management often extends beyond entities with IP network
interfaces, to non-IP building systems accessed via a gateway.
Requirements in this document do not cover details of these
networks, but specify means for opening IP network management
towards them.
Quittek, et al. Expires January 4, 2013 [Page 6]
Internet-Draft Requirements for Energy Management July 2012
These specific issues of energy management and a set of further ones
are covered by requirements specified in Sections 7 and 8.
The requirements in these sections need a new energy management
framework that deals with the specific nature of energy management.
The actual standards documents, such as MIB module specifications,
address conformance by specifying which feature must, should, or may
be implemented by compliant implementations.
2. Terminology
Energy
That which does work or is capable of doing work. As used by
electric utilities, it is generally a reference to electrical
energy and is measured in kilo-watt hours (kWh) [IEEE-100].
Power
The time rate at which energy is emitted, transferred, or
received; usually expressed in watts (or in joules per second)
[IEEE-100].
Energy management
Energy Management is a set of functions for measuring, modeling,
planning, and optimizing networks to ensure that the network
elements and attached devices use energy efficiently and is
appropriate for the nature of the application and the cost
constraints of the organization [ITU-M.3400].
Energy management system
An Energy Management System is a combination of hardware and
software used to administer a network with the primary purpose
being energy management [Fed-Std-1037C].
Energy monitoring
Energy monitoring is a part of energy management that deals with
collecting or reading information from network elements and
attached devices and their components to aid in energy management.
Quittek, et al. Expires January 4, 2013 [Page 7]
Internet-Draft Requirements for Energy Management July 2012
Energy control
Energy control is a part of energy management that deals with
directing influence over network elements and attached devices and
their components.
Powered Entity
A Powered Entity is either a device or one of a device's
components that is subject to energy monitoring or control or
both.
Power Interface
A Power Interface is an interface at which a device is connected
to a power transmission medium at which it can receive power,
provice power, or both.
Power inlet
A power inlet is a Power Interface at which a device can receive
power fro other devices.
Power outlet
A power outlet is a Power Interface at which a device can provide
power to other devices.
Power State
A Power State is a condition or mode of a device that broadly
characterizes its capabilities, power consumption, and
responsiveness to input [IEEE-1621].
3. General Considerations Related to Energy Management
The basic objective of energy management is operating sets of devices
with minimal energy, while maintaining a certain level of service.
Use cases for energy management can be found in
[I-D.ietf-eman-applicability-statement].
3.1. Power states
Powered Entities can be set to an operational state that results in
the lowest power level that still meets the service level performance
objectives. In principle, there are four basic types of Power States
for a Powered Entity or for a whole system:
Quittek, et al. Expires January 4, 2013 [Page 8]
Internet-Draft Requirements for Energy Management July 2012
o full Power State
o reduced Power States (e.g. lower clock rate for processor, lower
data rate on a link, etc.)
o sleep state (not functional, but immediately available)
o off state (may require significant time to become operational)
In specific devices, the number of Power States and their properties
varies considerably. Simple powered entities may just have only the
extreme states, full power and off state. Many devices have three
basic Power States: on, off, and sleep. However, more finely grained
Power States can be implemented with many levels of each Power State.
3.2. Saving energy versus maintaining service level agreements
While the general objective of energy management is quite clear, the
way to attain that goal is often difficult. In many cases there is
no way of reducing power without the consequence of a potential
performance, service, or capacity degradation. Then a trade-off
needs to be dealt with between service level objectives and energy
minimization. In other cases a reduction of power can easily be
achieved while still maintaining sufficient service level
performance, for example, by switching Powered Entities to lower
Power States when higher performance is not needed.
3.3. Local versus network-wide energy management
Many energy saving functions are executed locally by a Powered
Entity; it monitors its usage and dynamically adapts its power
according to the required performance. It may, for example, switch
to a sleep state when it is not in use or out of scheduled business
hours. An energy management system may observe an entity's power
state and configure its power saving policies.
Energy savings can also be achieved with policies implemented by a
network management system that controls Power States of managed
entities. Information about the power received and provided by
Powered Entities in different Power States may be required to set
policies. Often this information is acquired best through
monitoring.
Both methods, network-wide and local energy management, have
advantages and disadvantages and often it is desirable to combine
them. Central management is often favorable for setting Power States
of a large number of entities at the same time, for example, at the
beginning and end of business hours in a building. Local management
is often preferable for power saving measures based on local
observations, such as high or low load of an entity.
Quittek, et al. Expires January 4, 2013 [Page 9]
Internet-Draft Requirements for Energy Management July 2012
3.4. Energy monitoring versus energy saving
Monitoring energy, power, and Power States alone does not reduce the
energy needed to run a Powered Entity. In fact, it may even increase
it slightly due to monitoring instrumentation that needs energy.
Reporting measured quantities over the network may also increase
energy use, though the acquired information may be an essential input
to control loops that save energy.
Monitoring energy and Power States can also be required for other
purposes including:
o investigating energy saving potential
o evaluating the effectiveness of energy saving policies and
measures
o deriving, implementing, and testing power management strategies
o accounting for the total power received and provided by a Powered
Entity, a network, or a service
o predicting a Powered Entity's reliability based on power usage
o choosing time of next maintenance cycle for a powered entity
3.5. Overview of energy management requirements
The following basic management functions are required:
o monitoring Power States
o monitoring power (energy conversion rate)
o monitoring (accumulated) received and provided energy
o monitoring power properties
o setting Power States
Power control is complementary to other energy savings measures such
as low power electronics, energy saving protocols, energy-efficient
device design (for example, low-power modes for components), and
energy-efficient network architectures. Measurement of received and
provided energy can provide useful data for developing these
technologies.
4. Identification of Powered Entities
Powered Entities must be uniquely identified. This includes entities
that are components of managed devices as well as entire devices.
For Powered Entities that report on or control other Powered Entities
it is important to identify the Powered Entities they report on or
control, see Section 7 or Section 8, respectively.
An entity may be an entire device or a component of it. Examples of
components of interest are a hard drive, a battery, or a line card.
Quittek, et al. Expires January 4, 2013 [Page 10]
Internet-Draft Requirements for Energy Management July 2012
It may be required to be able to control individual components to
save energy. For example, server blades can be switched off when the
overall load is low or line cards at switches may be powered down at
night.
Identifiers for devices and components are already defined in
standard MIB modules, such as the LLDP MIB module [IEEE-802.1AB] and
the LLDP-MED MIB module [ANSI-TIA-1057] for devices and the Entity
MIB module [RFC4133] and the Power Ethernet MIB [RFC3621] for
components of devices. Energy management needs means to link energy-
related information to such identifiers.
Instrumentation for measuring received and provided energy of a
device is typically more expensive than instrumentation for
retrieving its Power State. Many devices may provide Power State
information for all individual components separately, while reporting
the received and provided energy only for the entire device.
4.1. Identifying Powered Entities
The standard must provide means for uniquely identifying Powered
Entities . Uniqueness must be preserved such that collisions of
identities are avoided at potential receivers of monitored
information.
4.2. Persistence of identifiers
The standard must provide means for indicating whether identifiers of
Powered Entities are persistent across a re-start of the Powered
Entity.
4.3. Using entity identifiers of other MIB modules
The standard must provide means for re-using entity identifiers from
other standards including at least the following:
o the entPhysicalIndex in the Entity MIB module [RFC4133]
o the LldpPortNumber in the LLDP MIB module [IEEE-802.1AB] and in
the LLDP-MED MIB module [ANSI-TIA-1057]
o the pethPsePortIndex and the pethPsePortGroupIndex in the Power
Ethernet MIB [RFC3621]
Generic means for re-using other entity identifiers must be provided.
5. Information on Powered Entities
This section describes information on Powered Entities for which the
standard must provide means for retrieving and reporting.
Quittek, et al. Expires January 4, 2013 [Page 11]
Internet-Draft Requirements for Energy Management July 2012
Required information can be structured into seven groups.
Section 5.1 specifies requirements for general information on Powered
Entities , such as type of powered entity or context information.
Requirements for information on power inlets and power outlets of
Powered Entities are specified in Section 5.2. Monitoring of power
and energy is covered by Sections 5.3 and 5.5, respectively.
Section 5.4 covers requirements related to entities' Power States.
Section 5.6 specifies requirements for monitoring batteries.
Finally, the reporting of time series of values is covered by
Section 5.7.
5.1. General information on Powered Entities
For energy management it may be required to understand the role and
context of a Powered Entity. An energy management system may
aggregate values of received and provided energy according to a
defined grouping of entities. When controlling and setting Power
States it may be helpful to understand the grouping of the entity and
role of a Powered Entity in a network, for example, it may be
important to exclude some vital network devices from being switched
to lower power or even from being switched off.
5.1.1. Type of Powered Entity
The standard must provide means to configure, retrieve and report a
textual name or a description of a powered entity.
5.1.2. Context of Powered Entities
The standard must provide means for retrieving and reporting context
information on Powered Entities , for example, tags associated with a
Powered Entity that indicate the Powered Entity's role.
5.1.3. Significance of Powered Entities
The standard must provide means for retrieving and reporting the
significance of Powered Entities within its context, for example, how
important the Powered Entity is.
5.1.4. Power priority
The standard must provide means for retrieving and reporting power
priorities of Powered Entities . Power priorities indicate an order
in which Power States of Powered Entities are changed, for example,
to lower Power States for saving power.
Quittek, et al. Expires January 4, 2013 [Page 12]
Internet-Draft Requirements for Energy Management July 2012
5.1.5. Grouping of Powered Entities
The standard must provide means for grouping powered entities. This
can be achieved in multiple ways, for example, by providing means to
tag Powered Entities , to assign them to domains, or to assign device
types to them.
5.2. Power Interfaces
A Power Interface is either an inlet or an outlet. Some Power
Interfaces can change over time from being an inlet to being an
outlet and vice versa. However most power interfaces never change.
Powered Entities have power inlets at which they are supplied with
electric power. Most Powered Entities have a single power inlet,
while some have multiple inlets. Different power inlets on a device
are often connected to separate power distribution trees. For energy
monitoring, it is useful to retrieve information on the number of
inlets of a Powered Entity, the availability of power at inlets and
which of them are actually in use.
Powered Entities can have one or more power outlets for supplying
other Powered Entities with electric power.
For identifying and potentially controlling the source of power
received at an inlet, it may be required to identify the power outlet
of another Powered Entity at which the received power is provided.
Analogously, for each outlet it is of interest to identify the power
inlets that receive the power provided at a certain outlet. Such
information is also required for constructing the wiring topology of
electrical power distribution to Powered Entities .
Static properties of each Power Interface are required information
for energy management. Static properties include the kind of
electric current (AC or DC), the nominal voltage, the nominal AC
frequency, and the number of AC phases.
5.2.1. Lists of Power Interfaces
The standard must provide means for monitoring the list of Power
Interfaces.
5.2.2. Corresponding power outlet
The standard must provide means for identifying the power outlet that
provides the power received at a power inlet.
Quittek, et al. Expires January 4, 2013 [Page 13]
Internet-Draft Requirements for Energy Management July 2012
5.2.3. Corresponding power inlets
The standard must provide means for identifying the list of power
inlets that receive the power provided at a power outlet.
5.2.4. Availability of power
The standard must provide means for monitoring the availability of
power at each Power Interface. This indicates whether at a Power
Interfaces power supply is switched on or off.
5.2.5. Use of power
The standard must provide means for monitoring for each Power
Interfaces if it is in actual use. For inlets this means that the
Powered Entity actually receives power at the inlet. For outlets
this means that power is actually provided from it to one or more
powered entities.
5.2.6. Type of current
The standard must provide means for reporting the type of current (AC
or DC) for each Power Interface as well as for an entire Powered
Entity.
5.2.7. Nominal voltage
The standard must provide means for reporting the nominal voltage for
each Power Interface.
5.2.8. Nominal AC frequency
The standard must provide means for reporting the nominal AC
frequency for each Power Interface.
5.2.9. Number of AC phases
The standard must provide means for reporting the number of AC phases
for each Power Interface.
5.3. Power
Power is measured as an instantaneous value or as the average over a
time interval.
Obtaining highly accurate values for power and energy may be costly
if it requires dedicated metering hardware. Powered Entities without
the ability to measure their power and received and provided energy
Quittek, et al. Expires January 4, 2013 [Page 14]
Internet-Draft Requirements for Energy Management July 2012
with high accuracy may just report estimated values, for example
based on load monitoring, Power State, or even just the entity type.
Depending on how power and energy values are obtained, the confidence
in the reported value and its accuracy will vary. Powered Entities
reporting such values should qualify the confidence in the reported
values and quantify the accuracy of measurements. For reporting
accuracy, the accuracy classes specified in IEC 62053-21
[IEC.62053-21] and IEC 62053-22 [IEC.62053-22] should be considered.
Further properties of the supplied power are also of interest. For
AC power supply, power attributes beyond the real power to be
reported include the apparent power, the reactive power, and the
phase angle of the current or the power factor. For both AC and DC
power the power characteristics are also subject of monitoring.
Power parameters include the actual voltage, the actual frequency,
the Total Harmonic Distortion (THD) of voltage and current, the
impedance of an AC phase or of the DC supply. Power monitoring
should be in line with existing standards, such as [IEC.61850-7-4].
For some network management tasks it is desirable to receive
notifications from Powered Entities when their power value exceeds or
falls below given thresholds.
5.3.1. Real power
The standard must provide means for reporting the real power for each
Power Interface as well as for an entire Powered Entity. Reporting
power includes reporting the direction of power flow.
5.3.2. Power measurement interval
The standard must provide means for reporting the corresponding time
or time interval for which a power value is reported. The power
value can be measured at the corresponding time or averaged over the
corresponding time interval.
5.3.3. Power measurement method
The standard must provide means to indicate the method how these
values have been obtained. Based on how the measurement was
conducted, it is possible to associate a certain degree of confidence
with the reported power value. For example, there are methods of
measurement such as direct power measurement, or by estimation based
on performance values, or hard coding average power values for a
Powered Entity.
Quittek, et al. Expires January 4, 2013 [Page 15]
Internet-Draft Requirements for Energy Management July 2012
5.3.4. Accuracy of power and energy values
The standard must provide means for reporting the accuracy of
reported power and energy values.
5.3.5. Actual voltage and current
The standard must provide means for reporting the actual voltage and
actual current for each power interface as well as for an entire
Powered Entity. In case of AC power supply, means must be provided
for reporting the actual voltage and actual current per phase.
5.3.6. High/low power notifications
The standard must provide means for creating notifications if power
values of a Powered Entity rise above or fall below given thresholds.
5.3.7. Complex power
The standard must provide means for reporting the complex power for
each Power Interface and for each phase at a Power Interface.
Besides the real power, at least two out of the following three
quantities need to be reported: apparent power, reactive power, phase
angle. The phase angle can be substituted by the power factor.
5.3.8. Actual AC frequency
The standard must provide means for reporting the actual AC frequency
for each Power Interface.
5.3.9. Total harmonic distortion
The standard must provide means for reporting the Total Harmonic
Distortion (THD) of voltage and current for each Power Interface. In
case of AC power supply, means must be provided for reporting the THD
per phase.
5.3.10. Power supply impedance
The standard must provide means for reporting the impedance of power
supply for each Power Interface. In case of AC power supply, means
must be provided for reporting the impedance per phase.
5.4. Power State
Many Powered Entities have a limited number of discrete Power States.
There is a need to report the actual Power State of a Powered Entity,
Quittek, et al. Expires January 4, 2013 [Page 16]
Internet-Draft Requirements for Energy Management July 2012
and means for retrieving the list of all supported Power States.
Different standards bodies have already defined sets of Power States
for some Powered Entities , and others are creating new Power State
sets. In this context, it is desirable that the standard support
many of these power state standards. In order to support multiple
management systems possibly using different Power State sets, while
simultaneously interfacing with a particular Powered Entity, the
energy management standard must provide means for supporting multiple
Power State sets used simultaneously at a powered entity.
Power States have parameters that describe its properties. It is
required to have standardized means for reporting some key
properties, such as average power and maximum power of a Powered
Entity in a certain state.
There also is a need to report statistics on Power States including
the time spent and the received and provided energy in a Power State.
5.4.1. Actual Power State
The standard must provide means for reporting the actual Power State
of a Powered Entity.
5.4.2. List of supported Power States
The standard must provide means for retrieving the list of all
potential Power States of a Powered Entity.
5.4.3. Multiple Power State sets
The standard must provide means for supporting multiple Power State
sets simultaneously at a Powered Entity.
5.4.4. List of supported Power State sets
The standard must provide means for retrieving the list of all Power
State sets supported by a Powered Entity.
5.4.5. List of supported Power States within a set
The standard must provide means for retrieving the list of all
potential Power States of a Powered Entity for each supported Power
State set.
Quittek, et al. Expires January 4, 2013 [Page 17]
Internet-Draft Requirements for Energy Management July 2012
5.4.6. Maximum and average power per Power State
The standard must provide means for retrieving the maximum power and
the average power for each supported Power State. These values may
be static.
5.4.7. Power State statistics
The standard must provide means for monitoring statistics per Power
State including the total time spent in a Power State, the number of
times each state was entered and the last time each state was
entered. More Power State statistics are addressed by requirement
5.5.3.
5.4.8. Power State changes
The standard must provide means for generating a notification when
the actual Power State of a powered entity changes.
5.5. Energy
Monitoring of electrical energy received or provided by a Powered
Entity is a core function of energy management. Since energy is an
accumulated quantity, it is always reported for a certain interval of
time. This can be, for example, the time from the last restart of
the powered entity to the reporting time, the time from another past
event to the reporting time, the last given amount of time before the
reporting time, or a certain interval specified by two time stamps in
the past.
It is useful for Powered Entities to record their received and
provided energy per Power State and report these quantities.
5.5.1. Energy
The standard must provide means for reporting measured values of
energy and the direction of the energy flow received or provided by a
Powered Entity. The standard must also provide the means to report
the energy passing through each Power Interface.
5.5.2. Time intervals
The standard must provide means for reporting the time interval for
which an energy value is reported.
Quittek, et al. Expires January 4, 2013 [Page 18]
Internet-Draft Requirements for Energy Management July 2012
5.5.3. Energy per Power State
The standard must provide means for reporting the received and
provided energy for each individual power state. This extends the
requirement 5.4.7 on Power State statistics.
5.6. Battery State
Many Powered Entities contain batteries that supply them with power
when disconnected from electrical power distribution grids. The
status of these batteries is typically controlled by automatic
functions that act locally on the Powered Entity and manually by
users of the powered entity. There is a need to monitor the battery
status of these entities by network management systems.
Devices containing batteries can be modeled in two ways. The entire
device can be modeled as a single Powered Entity on which energy-
related information is reported or the battery can be modeled as an
individual Powered Entity for which energy-related information is
monitored individually according to requirements in Sections 5.1 to
5.5.
Further information on batteries is of interest for energy
management, such as the current charge of the battery, the number of
completed charging cycles, the charging state of the battery, and
further static and dynamic battery properties. It is desirable to
receive notifications if the charge of a battery becomes very low or
if a battery needs to be replaced.
5.6.1. Battery charge
The standard must provide means for reporting the current charge of a
battery.
5.6.2. Battery charging state
The standard must provide means for reporting the charging state
(charging, discharging, etc.) of a battery.
5.6.3. Battery charging cycles
The standard must provide means for reporting the number of completed
charging cycles of a battery.
5.6.4. Actual battery capacity
The standard must provide means for reporting the actual capacity of
a battery.
Quittek, et al. Expires January 4, 2013 [Page 19]
Internet-Draft Requirements for Energy Management July 2012
5.6.5. Static battery properties
The standard must provide means for reporting static properties of a
battery, including the nominal capacity, the number of cells, the
nominal voltage, and the battery technology.
5.6.6. Low battery charge notification
The standard must provide means for generating a notification when
the charge of a battery decreases below a given threshold.
5.6.7. Battery replacement notification
The standard must provide means for generating a notification when
the number of charging cycles of battery exceeds a given threshold.
5.6.8. Multiple batteries
The standard must provide means for meeting requirements 5.6.1 to
5.6.7 for each individual battery contained in a single Powered
Entity.
5.7. Time series of measured values
For some network management tasks, it is required to obtain time
series of measured values from Powered Entities , such as power,
energy, battery charge, etc.
In general time series measurements could be obtained in many
different ways. It should be avoided that such time series can only
be obtained through regular polling by the energy management system.
Means should be provided to either push such values from the location
where they are available to the management system or to have them
stored locally for a sufficiently long period of time such that a
management system can retrieve full time series.
The following issues are to be considered when designing time series
measurement and reporting functions:
1. Which quantities should be reported?
2. Which time interval type should be used (total, delta, sliding
window)?
3. Which measurement method should be used (sampled, continuous)?
4. Which reporting model should be used (push or pull)?
The most discussed and probably most needed quantity is energy. But
a need for others, such as power and battery charge can be identified
as well.
Quittek, et al. Expires January 4, 2013 [Page 20]
Internet-Draft Requirements for Energy Management July 2012
There are three time interval types under discussion for accumulated
quantities such as energy. They can be reported as total values,
accumulated between the last restart of the measurement and a certain
timestamp. Alternatively, energy can be reported as delta values
between two consecutive timestamps. Another alternative is reporting
values for sliding windows as specified in [IEC.61850-7-4].
For non-accumulative quantities, such as power, different measurement
methods are considered. Such quantities can be reported using values
sampled at certain time stamps or alternatively by mean values for
these quantities averaged between two (consecutive) time stamps or
over a sliding window.
Finally, time series can be reported using different reporting
models, particularly push-based or pull-based. Push-based reporting
can, for example, be realized by reporting power or energy values
using the IPFIX protocol [RFC5101],[RFC5102]. SNMP [RFC3411] is an
example for a protocol that can be used for realizing pull-based
reporting of time series.
For reporting time series of measured values the following
requirements have been identified. Further decisions concerning
issues discussed above need to be made when developing concrete
energy management standards.
5.7.1. Time series of energy values
The standard must provide means for reporting time series of energy
values.
5.7.2. Time series storage capacity
The management standard should provide means for reporting the number
of values of a time series that can be stored for later reporting.
6. Control of Powered Entities
Many Powered Entities control their Power State locally. Other
Powered Entities need interfaces for an energy management system to
control their Power State.
Power supply is typically not self-managed by powered entities. And
controlling power supply is typically not conducted as interaction
between energy management system and the Powered Entity itself. It
is rather an interaction between the management system and an entity
providing power at its power outlets. Similar to Power State
control, power supply control may be policy driven. Note that
Quittek, et al. Expires January 4, 2013 [Page 21]
Internet-Draft Requirements for Energy Management July 2012
shutting down the power supply abruptly may have severe consequences
for the Powered Entity.
6.1. Controlling Power States
The standard must provide means for setting Power States of Powered
Entities .
6.2. Controlling power supply
The standard must provide means for switching power supply off or
turning power supply on at power outlets providing power to one or
more Powered Entity.
7. Reporting on other Powered Entities
As discussed in Section 5, not all energy-related information may be
available at the concerned Powered Entity. Such information may be
provided by other Powered Entities . This section covers reporting
of information only. See Section 8 for requirements on controlling
other Powered Entities .
There are cases where a power supply unit switches power for several
Powered Entities by turning power on or off at a single power outlet
or where a power meter measures the accumulated power of several
Powered Entities at a single power line. Consequently, it should be
possible to report that a monitored value does not relate to just a
single Powered Entity, but is an accumulated value for a set of
Powered Entities . All of these Powered Entities belonging to that
set need to be identified.
If a Powered Entity has information about where energy-related
information on itself can be retrieved, then it would be useful to
communicate this information. This applies even if the information
only provides accumulated quantities for several Powered Entities .
7.1. Reports on other Powered Entities
The standard must provide means for a Powered Entity to report
information on another Powered Entity.
7.2. Identity of other Powered Entities on which is reported
For entities that report on one or more other entities, the standard
must provide means for reporting the identity of other Powered
Entities on which information is reported.
Quittek, et al. Expires January 4, 2013 [Page 22]
Internet-Draft Requirements for Energy Management July 2012
7.3. Reporting quantities accumulated over multiple Powered Entities
The standard must provide means for reporting the list of all Powered
Entities from which contributions are included in an accumulated
value.
7.4. List of all Powered Entities on which is reported
For entities that report on one or more other entities, the standard
must provide means for reporting the complete list of all those
Powered Entities on which energy-related information can be reported.
7.5. Content of reports on other Powered Entities
For entities that report on one or more other entities, the standard
must provide means for indicating which energy-related information
can be reported for which of those Powered Entities .
7.6. Indicating source of remote information
For an entity that has one or more other entities reporting on its
behalf, the standard must provide means for the entity to indicate
which information is available at which other entity.
8. Controlling Other Powered Entities
This section specifies requirements for controlling Power States and
power supply of Powered Entities by communicating with other Powered
Entities that have means for controlling Power State or power supply
of others.
8.1. Controlling Power States of other Powered Entities
Some Powered Entities have control over Power States of other Powered
Entities . For example a gateway to a building system may have means
to control the Power State of powered entities in the building that
do not have an IP interface. For this scenario and other similar
cases means are needed to make this control accessible to the energy
management system.
In addition to this, it is required that a Powered Entity that has
its state controlled by other Powered Entities has means to report
the list of these other Powered Entities .
Quittek, et al. Expires January 4, 2013 [Page 23]
Internet-Draft Requirements for Energy Management July 2012
8.1.1. Control of Power States of other Powered Entities
The standard must provide means for an energy management system to
send Power State control commands to a Powered Entity that concern
the Power States of other Powered Entities than the one the command
was sent to.
8.1.2. Identity of other Power State controlled entities
The standard must provide means for reporting the identities of the
Powered Entities for which the reporting Powered Entity has means to
control their Power States.
8.1.3. List of all Power State controlled entities
The standard must provide means for a Powered Entity to report the
list of all Powered Entities for which it can control the Power
State.
8.1.4. List of all Power State controllers
The standard must provide means for a Powered Entity that receives
commands controlling its Power State from other Powered Entities to
report the list of all those entities.
8.2. Controlling power supply
Some Powered Entities may have control of the power supply of other
Powered Entities , for example, because the other Powered Entity is
supplied via a power outlet of the Powered Entity. For this and
similar cases means are needed to make this control accessible to the
energy management system. This need is already addressed by
requirement 6.2.
In addition, it is required that a Powered Entity that has its supply
controlled by other Powered Entities has means to report the list of
these other Powered Entities . This need is already addressed by
requirements 5.2.2 and 5.2.3.
9. Security Considerations
Controlling Power State and power supply of powered entities are
highly sensitive actions since they can significantly affect the
operation of directly and indirectly affected devices. Therefore all
control actions addressed in 6 and 8 must be sufficiently protected
through authentication, authorization, and integrity protection
mechanisms.
Quittek, et al. Expires January 4, 2013 [Page 24]
Internet-Draft Requirements for Energy Management July 2012
Monitoring energy-related quantities of a Powered Entity addressed in
Sections 5 - 8 can be used to derive more information than just the
received and provided energy, so monitored data requires privacy
protection. Monitored data may be used as input to control,
accounting, and other actions, so integrity of transmitted
information and authentication of the origin may be needed.
9.1. Secure energy management
The standard must provide privacy, integrity, and authentication
mechanisms for all actions addressed in Sections 5 - 8. The security
mechanisms must address all threats listed in Section 1.4 of
[RFC3411].
10. IANA Considerations
This document has no actions for IANA.
11. Acknowledgements
The authors would like to thank Ralf Wolter for his first essay on
this draft. Many thanks to William Mielke, John Parello, Bruce
Nordman, JinHyeock Choi, Georgios Karagiannis, and Michael Suchoff
for helpful comments on the draft.
12. Informative References
[RFC1628] Case, J., "UPS Management Information Base", RFC 1628,
May 1994.
[RFC3411] Harrington, D., Presuhn, R., and B. Wijnen, "An
Architecture for Describing Simple Network Management
Protocol (SNMP) Management Frameworks", STD 62, RFC 3411,
December 2002.
[RFC3433] Bierman, A., Romascanu, D., and K. Norseth, "Entity Sensor
Management Information Base", RFC 3433, December 2002.
[RFC3621] Berger, A. and D. Romascanu, "Power Ethernet MIB",
RFC 3621, December 2003.
[RFC3805] Bergman, R., Lewis, H., and I. McDonald, "Printer MIB v2",
RFC 3805, June 2004.
[RFC4133] Bierman, A. and K. McCloghrie, "Entity MIB (Version 3)",
Quittek, et al. Expires January 4, 2013 [Page 25]
Internet-Draft Requirements for Energy Management July 2012
RFC 4133, August 2005.
[RFC4268] Chisholm, S. and D. Perkins, "Entity State MIB", RFC 4268,
November 2005.
[RFC5101] Claise, B., "Specification of the IP Flow Information
Export (IPFIX) Protocol for the Exchange of IP Traffic
Flow Information", RFC 5101, January 2008.
[RFC5102] Quittek, J., Bryant, S., Claise, B., Aitken, P., and J.
Meyer, "Information Model for IP Flow Information Export",
RFC 5102, January 2008.
[I-D.ietf-eman-applicability-statement]
Silver, L., Chandramouli, M., and B. Nordman, "Energy
Management (EMAN) Applicability Statement",
draft-ietf-eman-applicability-statement-01 (work in
progress), June 2012.
[ACPI.R30b]
Hewlett-Packard Corporation, Intel Corporation, Microsoft
Corporation, Phoenix Corporation, and Toshiba Corporation,
"Advanced Configuration and Power Interface
Specification, Revision 3.0b", October 2006.
[ANSI-TIA-1057]
Telecommunications Industry Association, "ANSI-TIA-1057-
2006 - TIA Standard - Telecommunications - IP Telephony
Infrastructure - Link Layer Discovery Protocol for Media
Endpoint Devices", April 2006.
[DMTF.DSP1027]
Dasari (ed.), R., Davis (ed.), J., and J. Hilland (ed.),
"Power State Management Profile", September 2008.
[Fed-Std-1037C]
United States National Communications System Technology &
Standards Division, "Federal Standard 1037C -
Telecommunications: Glossary of Telcommunication Terms",
August 1996.
[IEEE-ISTO]
Printer Working Group, "PWG 5106.4 - PWG Power Management
Model for Imaging Systems 1.0", February 2011.
[IEEE-100]
IEEE, "Authoritative Dictionary of IEEE Standards Terms,
IEEE 100, Seventh Edition", December 2000.
Quittek, et al. Expires January 4, 2013 [Page 26]
Internet-Draft Requirements for Energy Management July 2012
[IEC.62053-21]
International Electrotechnical Commission, "Electricity
metering equipment (a.c.) - Particular requirements - Part
22: Static meters for active energy (classes 1 and 2)",
2003.
[IEC.62053-22]
International Electrotechnical Commission, "Electricity
metering equipment (a.c.) - Particular requirements - Part
22: Static meters for active energy (classes 0,2 S and
0,5 S)", 2003.
[IEC.61850-7-4]
International Electrotechnical Commission, "Communication
networks and systems for power utility automation - Part
7-4: Basic communication structure - Compatible logical
node classes and data object classes", 2010.
[IEEE-1621]
Institute of Electrical and Electronics Engineers, "IEEE
P1621-2004 -Draft Standard for User Interface Elements
in Power Control of Electronic Devices Employed in Office
Consumer Environments", June 2005.
[IEEE-802.1AB]
IEEE Computer Society, "IEEE Std 802.1AB-2009 - IEEE
Standard for Local and metropolitan area networks -
Station and Media Access Control Discovery", September
2009.
[ITU-M.3400]
International Telcommunication Union, "ITU-T
Recommendation M.3400 - Series M: TMN and Network
Maintenance: International Transmission Systems,
Telephone Circuits, Telegraphy, Facsimile and Leased
Circuits - Telecommunications Management Network - TMN
management functions", February 2000.
Appendix A. Existing Standards
This section analyzes existing standards for energy and Power State
monitoring. It shows that there are already several standards that
cover only some part of the requirements listed above, but even all
together they do not cover all of the requirements for energy
management.
Quittek, et al. Expires January 4, 2013 [Page 27]
Internet-Draft Requirements for Energy Management July 2012
A.1. Existing IETF Standards
There are already RFCs available that address a subset of the
requirements.
A.1.1. ENTITY MIB
The ENTITY-MIB module defined in [RFC4133] was designed to model
physical and logical entities of a managed system. A physical entity
is an identifiable physical component. A logical entity can use one
or more physical entities. From an energy monitoring perspective of
a managed system, the ENTITY-MIB modeling framework can be reused and
whenever RFC 4133 [RFC4133] has been implemented. The
entPhysicalIndex from entPhysicalTable can be used to identify an
entity/component. However, there are use cases of energy monitoring,
where the application of the ENTITY-MIB does not seem readily
apparent and some of those entities could be beyond the original
scope and intent of the ENTITY-MIB.
Consider the case of remote devices attached to the network, and the
network device could collect the energy measurement and report on
behalf of such attached devices. Some of the remote devices such as
PoE phones attached to a switch port have been considered in the
Power-over-Ethernet MIB module [RFC3621]. However, there are many
other devices such as a computer, which draw power from a wall outlet
or building HVAC devices which seem to be beyond the original scope
of the ENTITY-MIB.
Yet another example, is smart-PDUs, which can report the energy
provided to the device attached to the power outlet of the PDU. In
some cases, the device can be attached to multiple to power outlets.
Thus, the energy measured at multiple outlets need to be aggregated
to determine the energy provided to a single device. From mapping
perspective, between the PDU outlets and the device this is a many-
to-one mapping. It is not clear if such a many-to-one mapping is
feasible within the ENTITY-MIB framework.
A.1.2. ENTITY STATE MIB
RFC 4268 [RFC4268] defines the ENTITY STATE MIB module.
Implementations of this module provide information on entities
including the standby status (hotStandby, coldStandby,
providingService), the operational status (disabled, enabled,
testing), the alarm status (underRepair, critical, major, minor,
warning), and the usage status (idle, active, busy). This
information is already useful as input for policy decisions and for
other network management tasks. However, the number of states would
cover only a small subset of the requirements for Power State
Quittek, et al. Expires January 4, 2013 [Page 28]
Internet-Draft Requirements for Energy Management July 2012
monitoring and it does not provide means for energy monitoring. For
associating the information conveyed by the ENTITY STATE MIB to
specific components of a device, the ENTITY STATE MIB module makes
use of the means provided by the ENTITY MIB module [RFC4133].
Particularly, it uses the entPhysicalIndex for identifying entities.
The standby status provided by the ENTITY STATE MIB module is related
to Power States required for energy management, but the number of
states is too restricted for meeting all energy management
requirements. For energy management several more Power States are
required, such as different sleep and operational states as defined
by the Advanced Configuration and Power Interface (ACPI) [ACPI.R30b]
or the DMTF Power State Management Profile [DMTF.DSP1027].
A.1.3. ENTITY SENSOR MIB
RFC 3433 [RFC3433] defines the ENTITY SENSOR MIB module.
Implementations of this module offer a generic way to provide data
collected by a sensor. A sensor could be an energy meter delivering
measured values in Watt. This could be used for reporting current
power of an entity and its components. Furthermore, the ENTITY
SENSOR MIB can be used to retrieve the accuracy of the used power
meter.
Similar to the ENTITY STATE MIB module, the ENTITY SENSOR MIB module
makes use of the means provided by the ENTITY MIB module [RFC4133]
for relating provided information to components of a device.
However, there is no unit available for reporting energy quantities,
such as, for example, watt seconds or kilowatt hours, and the ENTITY
SENSOR MIB module does not support reporting accuracy of measurements
according to the IEC / ANSI accuracy classes, which are commonly in
use for electric power and energy measurements. The ENTITY SENSOR
MIB modules only provides a coarse-grained method for indicating
accuracy by stating the number of correct digits of fixed point
values.
A.1.4. UPS MIB
RFC 1628 [RFC1628] defines the UPS MIB module. Implementations of
this module provide information on the current real power of entities
attached to an uninterruptible power supply (UPS) device. This
application would require identifying which entity is attached to
which port of the UPS device.
UPS MIB provides information on the state of the UPS network. The
MIB module contains several variables that are used to identify the
UPS entity (name, model,..), the Battery State, to characterize the
Quittek, et al. Expires January 4, 2013 [Page 29]
Internet-Draft Requirements for Energy Management July 2012
input load to the UPS, to characterize the output from the UPS, to
indicate the various alarm events. The measurements of power in UPS
MIB are in Volts, Amperes and Watts. The units of power measurement
are RMS volts, RMS Amperes and are not based on Entity-Sensor MIB
[RFC3433].
A.1.5. POWER ETHERNET MIB
Similar to the UPS MIB, implementations of the POWER ETHERNET MIB
module defined in RFC3621 [RFC3621] provide information on the
current power of the entities that receive Power over Ethernet (PoE).
This information can be retrieved at the power sourcing equipment.
Analogous to the UPS MIB, it is required to identify which entities
are attached to which port of the power sourcing equipment.
The POWER ETHERNET MIB does not report power and energy on a per port
basis, but can report aggregated values for groups of ports. It does
not use objects of the ENTITY MIB module for identifying entities,
although this module existed already when the POWER ETHERNET MIB
modules was standardized.
A.1.6. LLDP MED MIB
The Link Layer Discovery Protocol (LLDP) defined in IEEE 802.1ab is a
data link layer protocol used by network devices for advertising of
their identities, capabilities, and interconnections on a LAN
network. The Media Endpoint Discovery (MED) (ANSI-TIA-1057) is an
enhancement of LLDP known as LLDP-MED. The LLDP-MED enhancements
specifically address voice applications. LLDP-MED covers 6 basic
areas: capabilities discovery, LAN speed and duplex discovery,
network policy discovery, location identification discovery,
inventory discovery, and power discovery.
A.2. Existing standards of other bodies
A.2.1. DMTF
The DMTF has defined a Power State management profile [DMTF.DSP1027]
that is targeted at computer systems. It is based on the DMTF's
Common Information Model (CIM) and it is rather an entity profile
than an actual energy monitoring standard.
The Power State management profile is used to describe and to manage
the Power State of computer systems. This includes e.g. means to
change the Power State of an entity (e.g. to shutdown the entity)
which is an aspect of but not sufficient for active energy
management.
Quittek, et al. Expires January 4, 2013 [Page 30]
Internet-Draft Requirements for Energy Management July 2012
A.2.2. OVDA
ODVA is an association consisting of members from industrial
automation companies. ODVA supports standardization of network
technologies based on the Common Industrial Protocol (CIP). Within
ODVA, there is a special interest group focused on energy and
standardization and inter-operability of energy aware entities.
A.2.3. IEEE-ISTO Printer WG
The charter of the IEEE-ISTO Printer Working Group is for open
standards that define printer related protocols, that printer
manufacturers and related software vendors shall benefit from the
interoperability provided by conformance to these standards. One
particular aspect the Printer WG is focused on is power monitoring
and management of network printers and imaging systems PWG Power
Management Model for Imaging Systems [IEEE-ISTO]. Clearly, these
devices are within the scope of energy management since these devices
receive power and are attached to the network. In addition, there is
ample scope of power management since printers and imaging systems
are not used that often. IEEE-ISTO Printer working group has defined
MIB modules for monitoring power and Power State series that can be
useful for power management of printers. The energy management
framework should also take into account the standards defined in the
Printer working group. In terms of other standards, IETF Printer MIB
RFC3805 [RFC3805] has been standardized, however, this MIB module
does not address power management of printers.
Authors' Addresses
Juergen Quittek (editor)
NEC Europe Ltd.
NEC Laboratories Europe
Network Research Division
Kurfuersten-Anlage 36
Heidelberg 69115
DE
Phone: +49 6221 4342-115
Email: quittek@neclab.eu
Quittek, et al. Expires January 4, 2013 [Page 31]
Internet-Draft Requirements for Energy Management July 2012
Rolf Winter
NEC Europe Ltd.
NEC Laboratories Europe
Network Research Division
Kurfuersten-Anlage 36
Heidelberg 69115
DE
Phone: +49 6221 4342-121
Email: Rolf.Winter@neclab.eu
Thomas Dietz
NEC Europe Ltd.
NEC Laboratories Europe
Network Research Division
Kurfuersten-Anlage 36
Heidelberg 69115
DE
Phone: +49 6221 4342-128
Email: Thomas.Dietz@neclab.eu