Internet Draft        802.3 Repeater MIB      14 February 1996






                          Definitions of Managed Objects
                         for IEEE 802.3 Repeater Devices


                                 14 February 1996


                     <draft-ietf-hubmib-repeater-dev-01.txt>



                                  Dan Romascanu
                           Madge Networks (Israel) Ltd.
                                  dan@lannet.com


                                 Kathryn de Graaf
                                 3Com Corporation
                              kdegraaf@isd.3com.com




          Status of this Memo

          This document is an Internet-Draft.  Internet-Drafts are
          working documents of the Internet Engineering Task Force
          (IETF), its areas, and its working groups.  Note that other
          groups may also distribute working documents as Internet-
          Drafts.

          Internet-Drafts are draft documents valid for a maximum of six
          months and may be updated, replaced, or obsoleted by other
          documents at any time.  It is inappropriate to use Internet-
          Drafts as reference material or to cite them other than as a
          "work in progress".

          To learn the current status of any Internet-Draft, please
          check the "1id-abstracts.txt" listing contained in the
          Internet-Drafts Shadow Directories on ds.internic.net (US East
          Coast), nic.nordu.net (Europe), ftp.isi.edu (US West Coast),





          Expires August 1996                                   [Page 1]


          Internet Draft        802.3 Repeater MIB      14 February 1996


          or munnari.oz.au (Pacific Rim).



          Abstract

          This memo defines an experimental portion of the Management
          Information Base (MIB) for use with network management
          protocols in the Internet community.  In particular, it
          defines objects for managing IEEE 802.3 10 and 100 Mb/second
          baseband repeaters based on IEEE Std 802.3 Section 30, "10 &
          100 Mb/s Management," October 26, 1995.

          This memo does not specify a standard for the Internet
          community.


          1.  The SNMPv2 Network Management Framework

          The SNMPv2 Network Management Framework consists of several
          major components.  They include:

          o    RFC 1902 which defines the SMI, the mechanisms used for
               describing and naming objects for the purpose of
               management.

          o    STD 17, RFC 1213 defines MIB-II, the core set of managed
               objects for the Internet suite of protocols.

          o    RFC 1905 which defines the protocol used for network
               access to managed objects.

          The Framework permits new objects to be defined for the
          purpose of experimentation and evaluation.


          1.1.  Object Definitions

          Managed objects are accessed via a virtual information store,
          termed the Management Information Base or MIB.  Objects in the
          MIB are defined using the subset of Abstract Syntax Notation
          One (ASN.1) defined in the SMI.  In particular, each object
          type is named by an OBJECT IDENTIFIER, an administratively
          assigned name.  The object type together with an object
          instance serves to uniquely identify a specific instantiation





          Expires August 1996                                   [Page 2]


          Internet Draft        802.3 Repeater MIB      14 February 1996


          of the object.  For human convenience, we often use a textual
          string, termed the descriptor, to refer to the object type.
















































          Expires August 1996                                   [Page 3]


          Internet Draft        802.3 Repeater MIB      14 February 1996


          2.  Overview

          Instances of the object types defined in this memo represent
          attributes of an IEEE 802.3 (Ethernet-like) repeater, as
          defined by Section 9, "Repeater Unit for 10 Mb/s Baseband
          Networks" in the IEEE 802.3/ISO 8802-3 CSMA/CD standard [1],
          and Section 27, "Repeater for 100 Mb/s Baseband Networks" in
          the IEEE Standard 802.3u-1995 [2].

          These Repeater MIB objects may be used to manage non-standard
          repeater-like devices, but defining objects to describe
          implementation-specific properties of non-standard repeater-
          like devices is outside the scope of this memo.

          The definitions presented here are based on Section 30.4,
          "Layer Management for 10 and 100 Mb/s Baseband Repeaters" and
          Annex 30A, "GDMO Specificataions for 802.3 managed objects" of
          [3].

          Implementors of these MIB objects should note that [3]
          explicitly describes when, where, and how various repeater
          attributes are measured.  The IEEE document also describes the
          effects of repeater actions that may be invoked by
          manipulating instances of the MIB objects defined here.

          The counters in this document are defined to be the same as
          those counters in [3], with the intention that the same
          instrumentation can be used to implement both the IEEE and
          IETF management standards.

          2.1.  Structure of the MIB

          Objects in this MIB are arranged into MIB groups.  Each MIB
          group is organized as a set of related objects.

          2.1.1.  The Basic Group Definitions

          This group contains the objects which are applicable to all
          repeaters.  It contains status, parameter and control objects
          for each repeater within the managed system, for the port
          groups within the system, and for the individual ports









          Expires August 1996                                   [Page 4]


          Internet Draft        802.3 Repeater MIB      14 February 1996


          themselves.

          2.1.2.  The Monitor Group Definitions

          This group contains monitoring statistics for each repeater
          within the system and for individual ports.

          2.1.3.  The Address Tracking Group Definitions

          This group contains objects for tracking the MAC addresses of
          the DTEs attached to the ports within the system.

          2.1.4.  The Top N Group Definitions

          This group contains objects for tracking the ports with the
          most activity within the system or within particular
          repeaters.

          2.2.  Relationship to Other MIBs

          2.2.1.  Relationship to RFC 1516

          This MIB is intended as a superset of that defined by RFC
          1516, which will go to historic status.  This MIB includes all
          of the objects contained in that MIB, plus some additional
          ones, mainly for support for multiple repeaters and for
          100BASE-T management.  Certain objects have been deprecated;
          in particular, those scalar objects used for managing a single
          repeater are now of minimal use since they are duplicated in
          the rptrInfoTable and rptrMonitorTable definitions.

          2.2.2.  Relationship to MIB-II

          It is assumed that a repeater implementing this MIB will also
          implement (at least) the 'system' group defined in MIB-II [5].

          2.2.2.1.  Relationship to the 'system' group

          In MIB-II, the 'system' group is defined as being mandatory
          for all systems such that each managed entity contains one
          instance of each object in the 'system' group.  Thus, those
          objects apply to the entity even if the entity's sole









          Expires August 1996                                   [Page 5]


          Internet Draft        802.3 Repeater MIB      14 February 1996


          functionality is management of repeaters.

          2.2.2.2.  Relationship to the 'interfaces' group

          In MIB-II, the 'interfaces' group is defined as being
          mandatory for all systems and contains information on an
          entity's interfaces, where each interface is thought of as
          being attached to a 'subnetwork'.  (Note that this term is not
          to be confused with 'subnet' which refers to an addressing
          partitioning scheme used in the Internet suite of protocols.)

          This Repeater MIB uses the notion of ports on a repeater.  The
          concept of a MIB-II interface has NO specific relationship to
          a repeater's port.  Therefore, the 'interfaces' group applies
          only to the one (or more) network interfaces on which the
          entity managing the repeater sends and receives management
          protocol operations, and does not apply to the repeater's
          ports.

          This is consistent with the physical-layer nature of a
          repeater.  A repeater is a bitwise store-and-forward device.
          It recognizes activity and bits, but does not process incoming
          data based on any packet-related information (such as checksum
          or addresses).  A repeater has no MAC address, no MAC
          implementation, and does not pass packets up to higher-level
          protocol entities for processing.

          (When a network management entity is observing a repeater, it
          may appear as though the repeater is passing packets to a
          higher-level protocol entity.  However, this is only a means
          of implementing management, and this passing of management
          information is not part of the repeater functionality.)


















          Expires August 1996                                   [Page 6]


          Internet Draft        802.3 Repeater MIB      14 February 1996


          3.  Definitions


          SNMP-REPEATER-MIB DEFINITIONS ::= BEGIN

          IMPORTS
              experimental,
              Counter32, Counter64, Integer32, Gauge32,
              TimeTicks, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
                  FROM SNMPv2-SMI
              TimeStamp, DisplayString, MacAddress, TEXTUAL-CONVENTION,
              RowStatus
                  FROM SNMPv2-TC
              OBJECT-GROUP, MODULE-COMPLIANCE
                  FROM SNMPv2-CONF
--              mib-2
--                  FROM RFC1213-MIB
              OwnerString
                  FROM RFC1271-MIB;


          snmpRptrMod MODULE-IDENTITY
              LAST-UPDATED    "9602140000Z"
              ORGANIZATION    "IETF HUB MIB Working Group"
              CONTACT-INFO
                  "WG E-mail: hubmib@hprnd.rose.hp.com

                       Chair: Dan Romascanu
                      Postal: Madge Networks (Israel) Ltd.
                              Atidim Technology Park, Bldg. 3
                              Tel Aviv 61131, Israel
                         Tel: 972-3-6458414, 6458458
                         Fax: 972-3-6487146
                      E-mail: dan@lannet.com

                      Editor: Kathryn de Graaf
                      Postal: 3Com Corporation
                              118 Turnpike Rd.
                              Southborough, MA  01772
                              USA
                         Tel: (508)229-1627
                         Fax: (508)490-5882
                      E-mail: kdegraaf@isd.3com.com"
              DESCRIPTION
                  "Management information for 802.3 repeaters.





          Expires August 1996                                   [Page 7]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                  The following references are used throughout
                  this MIB module:

                  [IEEE 802.3 Std]
                      refers to IEEE 802.3/ISO 8802-3 Information
                      processing systems - Local area networks -
                      Part 3: Carrier sense multiple access with
                      collision detection (CSMA/CD) access method
                      and physical layer specifications (1993).

                  [IEEE 802.3 Mgt]
                      refers to IEEE 802.3u-1995, '10 Mb/s &
                      100 Mb/s Management, Section 30,'
                      Supplement to ANSI/IEEE 802.3.

                  The following terms are used throughout this
                  MIB module:

                  System -

                  Chassis -

                  Repeater-unit -

                  Trivial repeater-unit - an isolated port that can
                          gather statistics.

                  Group -

                  System interconnect segment -

                  Stack -

                  Unit -

                  Module -
                  "
              REVISION "9309010000Z"
              DESCRIPTION
                  "Published as RFC 1516"
              REVISION "9210010000Z"
              DESCRIPTION
                  "Published as RFC 1368"
              ::= { snmpDot3RptrMgt 5 }






          Expires August 1996                                   [Page 8]


          Internet Draft        802.3 Repeater MIB      14 February 1996


          snmpDot3RptrMgt OBJECT IDENTIFIER ::= { experimental x }


          OptMacAddr ::= TEXTUAL-CONVENTION
              DISPLAY-HINT    "1x:"
              STATUS          current
              DESCRIPTION
                  "Either a 6 octet address in the `canonical'
                  order defined by IEEE 802.1a, i.e., as if it
                  were transmitted least significant bit first
                  if a value is available or a zero length string."
              REFERENCE
                  "See MacAddress in SNMPv2-TC. The only difference
                  is that a zero length string is allowed as a value
                  for OptMacAddr and not for MacAddress."
              SYNTAX OCTET STRING (SIZE (0 | 6))



          -- Basic information at the repeater, group, and port level.

          rptrBasicPackage
              OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 1 }
            rptrRptrInfo
                  OBJECT IDENTIFIER ::= { rptrBasicPackage 1 }
            rptrGroupInfo
                  OBJECT IDENTIFIER ::= { rptrBasicPackage 2 }
            rptrPortInfo
                  OBJECT IDENTIFIER ::= { rptrBasicPackage 3 }
            rptrAllRptrInfo
                  OBJECT IDENTIFIER ::= { rptrBasicPackage 4 }

          -- Monitoring information at the repeater, group, and port level.
          rptrMonitorPackage
              OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 2 }
            rptrMonitorRptrInfo
                  OBJECT IDENTIFIER ::= { rptrMonitorPackage 1 }
            rptrMonitorGroupInfo
                  OBJECT IDENTIFIER ::= { rptrMonitorPackage 2 }
            rptrMonitorPortInfo
                  OBJECT IDENTIFIER ::= { rptrMonitorPackage 3 }
            rptrMonitorAllRptrInfo
                  OBJECT IDENTIFIER ::= { rptrMonitorPackage 4 }

          -- Address tracking information at the repeater, group,





          Expires August 1996                                   [Page 9]


          Internet Draft        802.3 Repeater MIB      14 February 1996


          -- and port level.
          rptrAddrTrackPackage
              OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 3 }
            rptrAddrTrackRptrInfo
                  -- this subtree is currently unused
                  OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 1 }
            rptrAddrTrackGroupInfo
                  -- this subtree is currently unused
                  OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 2 }
            rptrAddrTrackPortInfo
                  OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 3 }

          -- TopN information.
          rptrTopNPackage
                  OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 4 }
            rptrTopNRptrInfo
                  -- this subtree is currently unused
                  OBJECT IDENTIFIER ::= { rptrTopNPackage 1 }
            rptrTopNGroupInfo
                  -- this subtree is currently unused
                  OBJECT IDENTIFIER ::= { rptrTopNPackage 2 }
            rptrTopNPortInfo
                  OBJECT IDENTIFIER ::= { rptrTopNPackage 3 }


          -- Old version of basic information at the repeater level.
          --
          -- In a system containing a single managed repeater,
          -- configuration, status, and control objects for the overall
          -- repeater.
          --
          -- The objects contained under the rptrRptrInfo subtree are
          -- intended for backwards compatibility with implementations of
          -- RFC 1516.  In newer implementations (both single- and
          -- multiple-repeater implementations) the rptrInfoTable should
          -- be implemented.  It is the preferred source of this information,
          -- as it contains the values for all repeaters managed by the
          -- agent.  In all cases, the objects in the rptrRptrInfo subtree
          -- are duplicates of the corresponding objects in the first entry
          -- of the rptrInfoTable.

          rptrGroupCapacity OBJECT-TYPE
              SYNTAX      Integer32 (1..2147483647)
              MAX-ACCESS  read-only
              STATUS      deprecated





          Expires August 1996                                  [Page 10]


          Internet Draft        802.3 Repeater MIB      14 February 1996


              DESCRIPTION
                      "The rptrGroupCapacity is the number of groups
                      that can be contained within the repeater.  Within
                      each managed repeater, the groups are uniquely
                      numbered in the range from 1 to rptrGroupCapacity.

                      Some groups may not be present in the repeater, in
                      which case the actual number of groups present
                      will be less than rptrGroupCapacity.  The number
                      of groups present will never be greater than
                      rptrGroupCapacity.

                      Note:  In practice, this will generally be the
                      number of field-replaceable units (i.e., modules,
                      cards, or boards) that can fit in the physical
                      repeater enclosure, and the group numbers will
                      correspond to numbers marked on the physical
                      enclosure."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.1.1.3,
                      aRepeaterGroupCapacity."
              ::= { rptrRptrInfo 1 }

          rptrOperStatus OBJECT-TYPE
              SYNTAX      INTEGER {
                            other(1),            -- undefined or unknown
                            ok(2),               -- no known failures
                            rptrFailure(3),      -- repeater-related failure
                            groupFailure(4),     -- group-related failure
                            portFailure(5),      -- port-related failure
                            generalFailure(6)    -- failure, unspecified type
                          }
              MAX-ACCESS  read-only
              STATUS      deprecated
              DESCRIPTION
                      "The rptrOperStatus object indicates the
                      operational state of the repeater.  The
                      rptrHealthText object may be consulted for more
                      specific information about the state of the
                      repeater's health.

                      In the case of multiple kinds of failures (e.g.,
                      repeater failure and port failure), the value of
                      this attribute shall reflect the highest priority
                      failure in the following order, listed highest





          Expires August 1996                                  [Page 11]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      priority first:

                          rptrFailure(3)
                          groupFailure(4)
                          portFailure(5)
                          generalFailure(6)."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.1.1.5, aRepeaterHealthState."
              ::= { rptrRptrInfo 2 }

          rptrHealthText OBJECT-TYPE
              SYNTAX      DisplayString (SIZE (0..255))
              MAX-ACCESS  read-only
              STATUS      deprecated
              DESCRIPTION
                      "The health text object is a text string that
                      provides information relevant to the operational
                      state of the repeater.  Agents may use this string
                      to provide detailed information on current
                      failures, including how they were detected, and/or
                      instructions for problem resolution.  The contents
                      are agent-specific."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.1.1.6, aRepeaterHealthText."
              ::= { rptrRptrInfo 3 }

          rptrReset OBJECT-TYPE
              SYNTAX      INTEGER {
                            noReset(1),
                            reset(2)
                          }
              MAX-ACCESS  read-write
              STATUS      deprecated
              DESCRIPTION
                      "Setting this object to reset(2) causes a
                      transition to the START state of Fig 9-2 in
                      section 9 [IEEE 802.3 Std] for a 10Mb/s repeater,
                      and the START state of Fig 27-2 in section 27
                      of that standard for a 100Mb/s repeater.

                      Setting this object to noReset(1) has no effect.
                      The agent will always return the value noReset(1)
                      when this object is read.

                      After receiving a request to set this variable to





          Expires August 1996                                  [Page 12]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      reset(2), the agent is allowed to delay the reset
                      for a short period.  For example, the implementor
                      may choose to delay the reset long enough to allow
                      the SNMP response to be transmitted.  In any
                      event, the SNMP response must be transmitted.

                      This action does not reset the management counters
                      defined in this document nor does it affect the
                      portAdminStatus parameters.  Included in this
                      action is the execution of a disruptive Self-Test
                      with the following characteristics:  a) The nature
                      of the tests is not specified.  b) The test resets
                      the repeater but without affecting management
                      information about the repeater.  c) The test does
                      not inject packets onto any segment.  d) Packets
                      received during the test may or may not be
                      transferred.  e) The test does not interfere with
                      management functions.

                      After performing this self-test, the agent will
                      update the repeater health information (including
                      rptrOperStatus and rptrHealthText), and send a
                      rptrHealth trap."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.1.2.1, acResetRepeater."
              ::= { rptrRptrInfo 4 }

          rptrNonDisruptTest OBJECT-TYPE
              SYNTAX      INTEGER {
                            noSelfTest(1),
                            selfTest(2)
                          }
              MAX-ACCESS  read-write
              STATUS      deprecated
              DESCRIPTION
                      "Setting this object to selfTest(2) causes the
                      repeater to perform a agent-specific, non-
                      disruptive self-test that has the following
                      characteristics:  a) The nature of the tests is
                      not specified.  b) The test does not change the
                      state of the repeater or management information
                      about the repeater.  c) The test does not inject
                      packets onto any segment.  d) The test does not
                      prevent the relay of any packets.  e) The test
                      does not interfere with management functions.





          Expires August 1996                                  [Page 13]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      After performing this test, the agent will update
                      the repeater health information (including
                      rptrOperStatus and rptrHealthText) and send a
                      rptrHealth trap.

                      Note that this definition allows returning an
                      'okay' result after doing a trivial test.

                      Setting this object to noSelfTest(1) has no
                      effect.  The agent will always return the value
                      noSelfTest(1) when this object is read."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.1.2.2,
                      acExecuteNonDisruptiveSelfTest."
              ::= { rptrRptrInfo 5 }

          rptrTotalPartitionedPorts OBJECT-TYPE
              SYNTAX      Gauge32
              MAX-ACCESS  read-only
              STATUS      deprecated
              DESCRIPTION
                      "This object returns the total number of ports in
                      the repeater whose current state meets all three
                      of the following criteria:  rptrPortOperStatus
                      does not have the value notPresent(3),
                      rptrPortAdminStatus is enabled(1), and
                      rptrPortAutoPartitionState is autoPartitioned(2)."
              ::= { rptrRptrInfo 6 }



          -- Basic information at the group level.
          --
          -- Configuration and status objects for each
          -- managed group in the system, independent
          -- of whether there is one or more managed
          -- repeater-units in the system.

          rptrGroupTable OBJECT-TYPE
              SYNTAX      SEQUENCE OF RptrGroupEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "Table of descriptive and status information about
                      the groups of ports."





          Expires August 1996                                  [Page 14]


          Internet Draft        802.3 Repeater MIB      14 February 1996


              ::= { rptrGroupInfo 1 }

          rptrGroupEntry OBJECT-TYPE
              SYNTAX      RptrGroupEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "An entry in the table, containing information
                      about a single group of ports."
              INDEX    { rptrGroupIndex }
              ::= { rptrGroupTable 1 }

          RptrGroupEntry ::=
              SEQUENCE {
                  rptrGroupIndex
                      Integer32,
                  rptrGroupDescr
                      DisplayString,
                  rptrGroupObjectID
                      OBJECT IDENTIFIER,
                  rptrGroupOperStatus
                      INTEGER,
                  rptrGroupLastOperStatusChange
                      TimeTicks,
                  rptrGroupPortCapacity
                      Integer32
              }

          rptrGroupIndex OBJECT-TYPE
              SYNTAX      Integer32 (1..2147483647)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This object identifies the group within the
                      system for which this entry contains
                      information."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.2.1.1, aGroupID."
              ::= { rptrGroupEntry 1 }

          rptrGroupDescr OBJECT-TYPE
              SYNTAX      DisplayString (SIZE (0..255))
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION





          Expires August 1996                                  [Page 15]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      "A textual description of the group.  This value
                      should include the full name and version
                      identification of the group's hardware type and
                      indicate how the group is differentiated from
                      other types of groups in the repeater.  Plug-in
                      Module, Rev A' or 'Barney Rubble 10BASE-T 4-port
                      SIMM socket Version 2.1' are examples of valid
                      group descriptions.

                      It is mandatory that this only contain printable
                      ASCII characters."
              ::= { rptrGroupEntry 2 }

          rptrGroupObjectID OBJECT-TYPE
              SYNTAX      OBJECT IDENTIFIER
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The vendor's authoritative identification of the
                      group.  This value may be allocated within the SMI
                      enterprises subtree (1.3.6.1.4.1) and provides a
                      straight-forward and unambiguous means for
                      determining what kind of group is being managed.

                      For example, this object could take the value
                      1.3.6.1.4.1.4242.1.2.14 if vendor 'Flintstones,
                      Inc.' was assigned the subtree 1.3.6.1.4.1.4242,
                      and had assigned the identifier
                      1.3.6.1.4.1.4242.1.2.14 to its 'Wilma Flintstone
                      6-Port FOIRL Plug-in Module.'"
              ::= { rptrGroupEntry 3 }

          rptrGroupOperStatus OBJECT-TYPE
              SYNTAX      INTEGER {
                            other(1),
                            operational(2),
                            malfunctioning(3),
                            notPresent(4),
                            underTest(5),
                            resetInProgress(6)
                          }
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "An object that indicates the operational status





          Expires August 1996                                  [Page 16]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      of the group.

                      A status of notPresent(4) indicates that the group
                      is temporarily or permanently physically and/or
                      logically not a part of the repeater.  It is an
                      implementation-specific matter as to whether the
                      agent effectively removes notPresent entries from
                      the table.

                      A status of operational(2) indicates that the
                      group is functioning, and a status of
                      malfunctioning(3) indicates that the group is
                      malfunctioning in some way."
              ::= { rptrGroupEntry 4 }

          rptrGroupLastOperStatusChange OBJECT-TYPE
              SYNTAX      TimeTicks
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "An object that contains the value of sysUpTime at
                      the time when the last of the following occurred:
                        1) the agent cold- or warm-started;
                        2) the row for the group was created (such
                           as when the group was added to the system); or
                        3) the value of rptrGroupOperStatus for the
                           group changed.

                      A value of zero indicates that the group's
                      operational status has not changed since the agent
                      last restarted."
              ::= { rptrGroupEntry 5 }

          rptrGroupPortCapacity OBJECT-TYPE
              SYNTAX      Integer32 (1..2147483647)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The rptrGroupPortCapacity is the number of ports
                      that can be contained within the group.  Valid
                      range is 1-2147483647.  Within each group, the
                      ports are uniquely numbered in the range from 1 to
                      rptrGroupPortCapacity.

                      Some ports may not be present in the system, in





          Expires August 1996                                  [Page 17]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      which case the actual number of ports present
                      will be less than the value of rptrGroupPortCapacity.
                      The number of ports present in the group will never
                      be greater than the value of rptrGroupPortCapacity.

                      Note:  In practice, this will generally be the
                      number of ports on a module, card, or board, and
                      the port numbers will correspond to numbers marked
                      on the physical embodiment."
              REFERENCE
                      "IEEE 802.3 Mgt, 30.4.2.1.2, aGroupPortCapacity."
              ::= { rptrGroupEntry 6 }


          -- Basic information at the port level.
          --
          -- Configuration and status objects for
          -- each managed repeater port in the system,
          -- independent of whether there is one or more
          -- managed repeater-units in the system.

          rptrPortTable OBJECT-TYPE
              SYNTAX      SEQUENCE OF RptrPortEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "Table of descriptive and status information about
                      the repeater ports in the system.  The number of
                      entries is independent of the number of repeaters
                      in the managed system."
              ::= { rptrPortInfo 1 }

          rptrPortEntry OBJECT-TYPE
              SYNTAX      RptrPortEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "An entry in the table, containing information
                      about a single port."
              INDEX    { rptrPortGroupIndex, rptrPortIndex }
              ::= { rptrPortTable 1 }

          RptrPortEntry ::=
              SEQUENCE {
                  rptrPortGroupIndex





          Expires August 1996                                  [Page 18]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      Integer32,
                  rptrPortIndex
                      Integer32,
                  rptrPortAdminStatus
                      INTEGER,
                  rptrPortAutoPartitionState
                      INTEGER,
                  rptrPortOperStatus
                      INTEGER,
                  rptrPortRptrId
                      Integer32
              }

          rptrPortGroupIndex OBJECT-TYPE
              SYNTAX      Integer32 (1..2147483647)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This object identifies the group containing the
                      port for which this entry contains information."
              ::= { rptrPortEntry 1 }

          rptrPortIndex OBJECT-TYPE
              SYNTAX      Integer32 (1..2147483647)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This object identifies the port within the group
                      for which this entry contains information.  This
                      identifies the port independently from the repeater
                      it may be attached to.  The numbering scheme for
                      ports is implementation specific; however, this
                      value can never be greater than
                      rptrGroupPortCapacity for the associated group."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.1, aPortID."
              ::= { rptrPortEntry 2 }

          rptrPortAdminStatus OBJECT-TYPE
              SYNTAX      INTEGER {
                            enabled(1),
                            disabled(2)
                          }
              MAX-ACCESS  read-write
              STATUS      current





          Expires August 1996                                  [Page 19]


          Internet Draft        802.3 Repeater MIB      14 February 1996


              DESCRIPTION
                      "Setting this object to disabled(2) disables the
                      port.  A disabled port neither transmits nor
                      receives.  Once disabled, a port must be
                      explicitly enabled to restore operation.  A port
                      which is disabled when power is lost or when a
                      reset is exerted shall remain disabled when normal
                      operation resumes.

                      The admin status takes precedence over auto-
                      partition and functionally operates between the
                      auto-partition mechanism and the AUI/PMA.

                      Setting this object to enabled(1) enables the port
                      and exerts a BEGIN on the port's auto-partition
                      state machine.

                      (In effect, when a port is disabled, the value of
                      rptrPortAutoPartitionState for that port is frozen
                      until the port is next enabled.  When the port
                      becomes enabled, the rptrPortAutoPartitionState
                      becomes notAutoPartitioned(1), regardless of its
                      pre-disabling state.)"
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.2, aPortAdminState
                      and 30.4.3.2.1, acPortAdminControl."
              ::= { rptrPortEntry 3 }

          rptrPortAutoPartitionState OBJECT-TYPE
              SYNTAX      INTEGER {
                            notAutoPartitioned(1),
                            autoPartitioned(2)
                          }
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The autoPartitionState flag indicates whether the
                      port is currently partitioned by the repeater's
                      auto-partition protection.

                      The conditions that cause port partitioning are
                      specified in partition state machine in Sections
                      9 and 27 of [IEEE 802.3 Std].  They are not
                      differentiated here."
              REFERENCE





          Expires August 1996                                  [Page 20]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      "[IEEE 802.3 Mgt], 30.4.3.1.3, aAutoPartitionState."
              ::= { rptrPortEntry 4 }

          rptrPortOperStatus  OBJECT-TYPE
              SYNTAX      INTEGER {
                            operational(1),
                            notOperational(2),
                            notPresent(3)
                          }
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This object indicates the port's operational
                      status.  The notPresent(3) status indicates the
                      port is physically removed (note this may or may
                      not be possible depending on the type of port.)
                      The operational(1) status indicates that the port
                      is enabled (see rptrPortAdminStatus) and working,
                      even though it might be auto-partitioned (see
                      rptrPortAutoPartitionState).

                      If this object has the value operational(1) and
                      rptrPortAdminStatus is set to disabled(2), it is
                      expected that this object's value will soon change
                      to notOperational(2)."
              ::= { rptrPortEntry 5 }

          rptrPortRptrId OBJECT-TYPE
              SYNTAX      Integer32 (0..2147483647)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This object identifies the repeater to
                      which this port belongs.  The repeater
                      identified by a particular value of this object
                      is the same as that identified by the same
                      value of rptrInfoId.  A value of zero
                      indicates that this port currently is not
                      a member of any repeater."
              ::= { rptrPortEntry 6 }


          -- New version of basic information at the repeater level.
          --
          -- Configuration, status, and control objects for





          Expires August 1996                                  [Page 21]


          Internet Draft        802.3 Repeater MIB      14 February 1996


          -- each managed repeater in the system.

          rptrInfoTable OBJECT-TYPE
              SYNTAX      SEQUENCE OF RptrInfoEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "A table of information about each
                      non-trivial repeater. The number of entries
                      depends on the physical configuration of the
                      managed system."
              ::= { rptrAllRptrInfo 1 }

          rptrInfoEntry OBJECT-TYPE
              SYNTAX      RptrInfoEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "An entry in the table, containing information
                      about a single non-trivial repeater."
              INDEX    { rptrInfoId }
              ::= { rptrInfoTable 1 }

          RptrInfoEntry ::=
              SEQUENCE {
                  rptrInfoId
                      Integer32,
                  rptrInfoRptrType
                      INTEGER,
                  rptrInfoOperStatus
                      INTEGER,
                  rptrInfoReset
                      INTEGER,
                  rptrInfoNonDisruptTest
                      INTEGER,
                  rptrInfoPartitionedPorts
                      Gauge32,
                  rptrInfoLastChange
                      TimeStamp
              }

          rptrInfoId OBJECT-TYPE
              SYNTAX      Integer32 (1..2147483647)
              MAX-ACCESS  read-only
              STATUS      current





          Expires August 1996                                  [Page 22]


          Internet Draft        802.3 Repeater MIB      14 February 1996


              DESCRIPTION
                      "This object identifies the repeater for which
                      this entry contains information."
              ::= { rptrInfoEntry 1 }

          rptrInfoRptrType OBJECT-TYPE
              SYNTAX      INTEGER {
                            other(1),                -- undefined or unknown
                            tenMb(2),
                            onehundredMbClassI(3),
                            onehundredMbClassII(4)
                          }
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The rptrInfoRptrType returns a value that identifies
                      the CSMA/CD repeater type."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.1.1.2, aRepeaterType."
              ::= { rptrInfoEntry 2 }

          rptrInfoOperStatus OBJECT-TYPE
              SYNTAX      INTEGER {
                            other(1),
                            ok(2),
                            failure(3)
                          }
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The rptrInfoOperStatus object indicates the
                      operational state of the repeater."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.1.1.5, aRepeaterHealthState."
              ::= { rptrInfoEntry 3 }

          rptrInfoReset OBJECT-TYPE
              SYNTAX      INTEGER {
                            noReset(1),
                            reset(2)
                          }
              MAX-ACCESS  read-write
              STATUS      current
              DESCRIPTION
                      "Setting this object to reset(2) causes a





          Expires August 1996                                  [Page 23]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      transition to the START state of Fig 9-2 in
                      section 9 [IEEE 802.3 Std] for a 10Mb/s repeater,
                      and to the START state of Fig 27-2 in section 27
                      of that standard for a 100Mb/s repeater.

                      Setting this object to noReset(1) has no effect.
                      The agent will always return the value noReset(1)
                      when this object is read.

                      After receiving a request to set this variable to
                      reset(2), the agent is allowed to delay the reset
                      for a short period.  For example, the implementor
                      may choose to delay the reset long enough to allow
                      the SNMP response to be transmitted.  In any
                      event, the SNMP response must be transmitted.

                      This action does not reset the management counters
                      defined in this document nor does it affect the
                      portAdminStatus parameters.  Included in this
                      action is the execution of a disruptive Self-Test
                      with the following characteristics:  a) The nature
                      of the tests is not specified.  b) The test resets
                      the repeater but without affecting management
                      information about the repeater.  c) The test does
                      not inject packets onto any segment.  d) Packets
                      received during the test may or may not be
                      transferred.  e) The test does not interfere with
                      management functions.

                      After performing this self-test, the agent will
                      update the repeater health information (including
                      rptrInfoOperStatus), and send a rptrInfoHealth trap."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.1.2.1, acResetRepeater."
              ::= { rptrInfoEntry 4 }

          rptrInfoNonDisruptTest OBJECT-TYPE
              SYNTAX      INTEGER {
                            noSelfTest(1),
                            selfTest(2)
                          }
              MAX-ACCESS  read-write
              STATUS      current
              DESCRIPTION
                      "Setting this object to selfTest(2) causes the





          Expires August 1996                                  [Page 24]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      repeater to perform a agent-specific, non-
                      disruptive self-test that has the following
                      characteristics:  a) The nature of the tests is
                      not specified.  b) The test does not change the
                      state of the repeater or management information
                      about the repeater.  c) The test does not inject
                      packets onto any segment.  d) The test does not
                      prevent the relay of any packets.  e) The test
                      does not interfere with management functions.

                      After performing this test, the agent will update
                      the repeater health information (including
                      rptrInfoOperStatus) and send a rptrInfoHealth trap.

                      Note that this definition allows returning an
                      'okay' result after doing a trivial test.

                      Setting this object to noSelfTest(1) has no
                      effect.  The agent will always return the value
                      noSelfTest(1) when this object is read."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.1.2.2,
                      acExecuteNonDisruptiveSelfTest."
              ::= { rptrInfoEntry 5 }

          rptrInfoPartitionedPorts OBJECT-TYPE
              SYNTAX      Gauge32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This object returns the total number of ports in
                      the repeater whose current state meets all three
                      of the following criteria:  rptrPortOperStatus
                      does not have the value notPresent(3),
                      rptrPortAdminStatus is enabled(1), and
                      rptrPortAutoPartitionState is autoPartitioned(2)."
              ::= { rptrInfoEntry 6 }

          rptrInfoLastChange OBJECT-TYPE
              SYNTAX      TimeStamp
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The value of sysUpTime when any of the following
                      conditions occurred:





          Expires August 1996                                  [Page 25]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                        1) agent cold- or warm-started;
                        2) this instance of repeater was created
                           (such as when a device or module was
                           added to the system);
                        3) a change in the value of rptrInfoOperStatus;
                        4) ports were added or removed as members of
                           the repeater; or
                        5) any of the counters associated with this
                           repeater had a discontinuity."
              ::= { rptrInfoEntry 7 }




          --
          -- Old version of statistics at the repeater level.
          --
          -- Performance monitoring statistics for the repeater
          --
          -- In a system containing a single managed repeater-unit,
          -- the statistics object for the repeater-unit.

          -- The objects contained under the rptrMonitorRptrInfo subtree are
          -- intended for backwards compatibility with implementations of
          -- RFC 1516.  In newer implementations (both single- and
          -- multiple-repeater implementations), the rptrMonitorTable will
          -- be implemented.  It is the preferred source of this information,
          -- as it contains the values for all repeaters managed by the
          -- agent.  In all cases, the objects in the rptrMonitorRptrInfo
          -- subtree are duplicates of the corresponding objects in the
          -- first entry of the rptrMonitorTable.


          rptrMonitorTransmitCollisions OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      deprecated
              DESCRIPTION
                      "For a clause 9 (10Mb/s) repeater, this counter
                      is incremented every time the repeater state
                      machine enters the TRANSMIT COLLISION state
                      from any state other than ONE PORT LEFT
                      (Ref: Fig 9-2 [IEEE 802.3 Std]).

                      For a clause 27 repeater, this counter is





          Expires August 1996                                  [Page 26]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      incremented every time the repeater core state
                      diagram enters the Jam state as a result of
                      Activity(ALL) > 1 (fig 27-2 [IEEE 802.3 Std]).

                      The approximate minimum time for rollover of this
                      counter is 16 hours in a 10Mb/s repeater and 1.6
                      hours in a 100Mb/s repeater."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.1.1.8, aTransmitCollisions."
              ::= { rptrMonitorRptrInfo 1 }


          -- Statistics at the group level.
          --
          -- In a system containing a single managed repeater-unit,
          -- the statistics objects for each group.

          rptrMonitorGroupTable OBJECT-TYPE
              SYNTAX      SEQUENCE OF RptrMonitorGroupEntry
              MAX-ACCESS  not-accessible
              STATUS      deprecated
              DESCRIPTION
                      "Table of performance and error statistics for the
                      groups within the repeater.  The number of entries
                      is the same as that in the rptrGroupTable."
              ::= { rptrMonitorGroupInfo 1 }

          rptrMonitorGroupEntry OBJECT-TYPE
              SYNTAX    RptrMonitorGroupEntry
              MAX-ACCESS  not-accessible
              STATUS    deprecated
              DESCRIPTION
                      "An entry in the table, containing total
                      performance and error statistics for a single
                      group.  Regular retrieval of the information in
                      this table provides a means of tracking the
                      performance and health of the networked devices
                      attached to this group's ports.

                      The counters in this table are redundant in the
                      sense that they are the summations of information
                      already available through other objects.  However,
                      these sums provide a considerable optimization of
                      network management traffic over the otherwise
                      necessary retrieval of the individual counters





          Expires August 1996                                  [Page 27]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      included in each sum.

                      Note:  Group-level counters are
                      deprecated in this MIB.  It is recommended
                      that management applications instead use
                      the repeater-level counters contained in
                      the rptrMonTable."
              INDEX    { rptrMonitorGroupIndex }
              ::= { rptrMonitorGroupTable 1 }

          RptrMonitorGroupEntry ::=
              SEQUENCE {
                  rptrMonitorGroupIndex
                      Integer32,
                  rptrMonitorGroupTotalFrames
                      Counter32,
                  rptrMonitorGroupTotalOctets
                      Counter32,
                  rptrMonitorGroupTotalErrors
                      Counter32
              }

          rptrMonitorGroupIndex OBJECT-TYPE
              SYNTAX      Integer32 (1..2147483647)
              MAX-ACCESS  read-only
              STATUS      deprecated
              DESCRIPTION
                      "This object identifies the group within the
                      repeater for which this entry contains
                      information."
              ::= { rptrMonitorGroupEntry 1 }

          rptrMonitorGroupTotalFrames OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      deprecated
              DESCRIPTION
                      "The total number of frames of valid frame length
                      that have been received on the ports in this group
                      and for which the FCSError and CollisionEvent
                      signals were not asserted.  This counter is the
                      summation of the values of the
                      rptrMonitorPortReadableFrames counters for all of
                      the ports in the group.






          Expires August 1996                                  [Page 28]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      This statistic provides one of the parameters
                      necessary for obtaining the packet error rate.
                      The approximate minimum time for rollover of this
                      counter is 80 hours in a 10Mb/s repeater."
              ::= { rptrMonitorGroupEntry 2 }

          rptrMonitorGroupTotalOctets OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      deprecated
              DESCRIPTION
                      "The total number of octets contained in the valid
                      frames that have been received on the ports in
                      this group.  This counter is the summation of the
                      values of the rptrMonitorPortReadableOctets
                      counters for all of the ports in the group.

                      This statistic provides an indicator of the total
                      data transferred.  The approximate minimum time
                      for rollover of this counter is 58 minutes in a
                      10Mb/s repeater."
              ::= { rptrMonitorGroupEntry 3 }

          rptrMonitorGroupTotalErrors OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      deprecated
              DESCRIPTION
                      "The total number of errors which have occurred on
                      all of the ports in this group.  This counter is
                      the summation of the values of the
                      rptrMonitorPortTotalErrors counters for all of the
                      ports in the group."
              ::= { rptrMonitorGroupEntry 4 }


          -- Statistics at the port level.
          --

          rptrMonitorPortTable OBJECT-TYPE
              SYNTAX      SEQUENCE OF RptrMonitorPortEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "Table of performance and error statistics for the





          Expires August 1996                                  [Page 29]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      ports.  The number of entries is the same as that
                      in the rptrPortTable.

                      The columnar object rptrMonitorPortLastChange
                      is used to indicate possible discontinuities
                      of counter type columnar objects in the table."
              ::= { rptrMonitorPortInfo 1 }

          rptrMonitorPortEntry OBJECT-TYPE
              SYNTAX      RptrMonitorPortEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "An entry in the table, containing performance and
                      error statistics for a single port."
              INDEX    { rptrMonitorPortGroupIndex, rptrMonitorPortIndex }
              ::= { rptrMonitorPortTable 1 }

          RptrMonitorPortEntry ::=
              SEQUENCE {
                  rptrMonitorPortGroupIndex
                      Integer32,
                  rptrMonitorPortIndex
                      Integer32,
                  rptrMonitorPortReadableFrames
                      Counter32,
                  rptrMonitorPortReadableOctets
                      Counter32,
                  rptrMonitorPortFCSErrors
                      Counter32,
                  rptrMonitorPortAlignmentErrors
                      Counter32,
                  rptrMonitorPortFrameTooLongs
                      Counter32,
                  rptrMonitorPortShortEvents
                      Counter32,
                  rptrMonitorPortRunts
                      Counter32,
                  rptrMonitorPortCollisions
                      Counter32,
                  rptrMonitorPortLateEvents
                      Counter32,
                  rptrMonitorPortVeryLongEvents
                      Counter32,
                  rptrMonitorPortDataRateMismatches





          Expires August 1996                                  [Page 30]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      Counter32,
                  rptrMonitorPortAutoPartitions
                      Counter32,
                  rptrMonitorPortTotalErrors
                      Counter32,
                  rptrMonitorPortLastChange
                      TimeStamp
              }

          rptrMonitorPortGroupIndex OBJECT-TYPE
              SYNTAX      Integer32 (1..2147483647)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This object identifies the group containing the
                      port for which this entry contains information."
              ::= { rptrMonitorPortEntry 1 }

          rptrMonitorPortIndex OBJECT-TYPE
              SYNTAX      Integer32 (1..2147483647)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This object identifies the port within the group
                      for which this entry contains information."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.1, aPortID."
              ::= { rptrMonitorPortEntry 2 }

          rptrMonitorPortReadableFrames OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This object is the number of frames of valid
                      frame length that have been received on this port.
                      This counter is incremented by one for each frame
                      received on this port whose OctetCount is greater
                      than or equal to minFrameSize and less than or
                      equal to maxFrameSize (Ref: IEEE 802.3 Std,
                      4.4.2.1) and for which the FCSError and
                      CollisionEvent signals are not asserted.

                      A discontinuity may occur in the value
                      when the value of object





          Expires August 1996                                  [Page 31]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      rptrMonitorPortLastChange changes.

                      This statistic provides one of the parameters
                      necessary for obtaining the packet error rate.
                      The approximate minimum time for rollover of this
                      counter is 80 hours at 10Mb/s."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.4, aReadableFrames."
              ::= { rptrMonitorPortEntry 3 }

          rptrMonitorPortReadableOctets OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This object is the number of octets contained in
                      valid frames that have been received on this port.
                      This counter is incremented by OctetCount for each
                      frame received on this port which has been
                      determined to be a readable frame (i.e., including
                      FCS octets but excluding framing bits and dribble
                      bits).

                      A discontinuity may occur in the value
                      when the value of object
                      rptrMonitorPortLastChange changes.

                      This statistic provides an indicator of the total
                      data transferred.  The approximate minimum time
                      for rollover of this counter in a 10Mb/s repeater
                      is 58 minutes.

                      For ports receiving traffic at a maximum rate in
                      a 100Mb/s repeater, this counter can roll over
                      in less than 6 minutes.  Since that amount of time
                      could be less than a management station's poll cycle
                      time, in order to avoid a loss of information a
                      management station is advised to also poll the
                      rptrMonitorPortUpper32Octets object, or to use the
                      64-bit counter defined by
                      rptrMonitorPortHCReadableOctets instead of the
                      two 32-bit counters."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.5, aReadableOctets."
              ::= { rptrMonitorPortEntry 4 }





          Expires August 1996                                  [Page 32]


          Internet Draft        802.3 Repeater MIB      14 February 1996


          rptrMonitorPortFCSErrors OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This counter is incremented by one for each frame
                      received on this port with the FCSError signal
                      asserted and the FramingError and CollisionEvent
                      signals deasserted and whose OctetCount is greater
                      than or equal to minFrameSize and less than or
                      equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3
                      Std).

                      A discontinuity may occur in the value
                      when the value of object
                      rptrMonitorPortLastChange changes.

                      The approximate minimum time for rollover of this
                      counter is 80 hours at 10Mb/s."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.6,
                      aFrameCheckSequenceErrors."
              ::= { rptrMonitorPortEntry 5 }

          rptrMonitorPortAlignmentErrors OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This counter is incremented by one for each frame
                      received on this port with the FCSError and
                      FramingError signals asserted and CollisionEvent
                      signal deasserted and whose OctetCount is greater
                      than or equal to minFrameSize and less than or
                      equal to maxFrameSize (Ref: IEEE 802.3 Std,
                      4.4.2.1).  If rptrMonitorPortAlignmentErrors is
                      incremented then the rptrMonitorPortFCSErrors
                      Counter shall not be incremented for the same
                      frame.

                      A discontinuity may occur in the value
                      when the value of object
                      rptrMonitorPortLastChange changes.

                      The approximate minimum time for rollover of this





          Expires August 1996                                  [Page 33]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      counter is 80 hours at 10Mb/s."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.7, aAlignmentErrors."
              ::= { rptrMonitorPortEntry 6 }

          rptrMonitorPortFrameTooLongs OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This counter is incremented by one for each frame
                      received on this port whose OctetCount is greater
                      than maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std).
                      If rptrMonitorPortFrameTooLongs is incremented
                      then neither the rptrMonitorPortAlignmentErrors
                      nor the rptrMonitorPortFCSErrors counter shall be
                      incremented for the frame.

                      A discontinuity may occur in the value
                      when the value of object
                      rptrMonitorPortLastChange changes.

                      The approximate minimum time for rollover of this
                      counter is 61 days in a 10Mb/s repeater."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.8, aFramesTooLong."
              ::= { rptrMonitorPortEntry 7 }

          rptrMonitorPortShortEvents OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This counter is incremented by one for each
                      CarrierEvent on this port with ActivityDuration
                      less than ShortEventMaxTime.  ShortEventMaxTime is
                      greater than 74 bit times and less than 82 bit
                      times.  ShortEventMaxTime has tolerances included
                      to provide for circuit losses between a
                      conformance test point at the AUI and the
                      measurement point within the state machine.

                      Notes:

                      ShortEvents may indicate externally





          Expires August 1996                                  [Page 34]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      generated noise hits which will cause the repeater
                      to transmit Runts to its other ports, or propagate
                      a collision (which may be late) back to the
                      transmitting DTE and damaged frames to the rest of
                      the network.

                      Implementors may wish to consider selecting the
                      ShortEventMaxTime towards the lower end of the
                      allowed tolerance range to accommodate bit losses
                      suffered through physical channel devices not
                      budgeted for within this standard.

                      The significance of this attribute is different
                      in 10 and 100 Mb/s collision domains.  Clause 9
                      repeaters perform fragment extension of short
                      events which would be counted as runts on the
                      interconnect ports of other repeaters.  Clause
                      27 repeaters do not perform fragment extension.

                      A discontinuity may occur in the value
                      when the value of object
                      rptrMonitorPortLastChange changes.

                      The approximate minimum time for rollover of this
                      counter is 16 hours in a 10Mb/s repeater."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.9, aShortEvents."
              ::= { rptrMonitorPortEntry 8 }

          rptrMonitorPortRunts OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This counter is incremented by one for each
                      CarrierEvent on this port that meets one of the
                      following two conditions.  Only one test need be
                      made.  a) The ActivityDuration is greater than
                      ShortEventMaxTime and less than ValidPacketMinTime
                      and the CollisionEvent signal is deasserted.  b)
                      The OctetCount is less than 64, the
                      ActivityDuration is greater than ShortEventMaxTime
                      and the CollisionEvent signal is deasserted.
                      ValidPacketMinTime is greater than or equal to 552
                      bit times and less than 565 bit times.





          Expires August 1996                                  [Page 35]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      An event whose length is greater than 74 bit times
                      but less than 82 bit times shall increment either
                      the shortEvents counter or the runts counter but
                      not both.  A CarrierEvent greater than or equal to
                      552 bit times but less than 565 bit times may or
                      may not be counted as a runt.

                      ValidPacketMinTime has tolerances included to
                      provide for circuit losses between a conformance
                      test point at the AUI and the measurement point
                      within the state machine.

                      Runts usually indicate collision fragments, a
                      normal network event.  In certain situations
                      associated with large diameter networks a
                      percentage of collision fragments may exceed
                      ValidPacketMinTime.

                      A discontinuity may occur in the value
                      when the value of object
                      rptrMonitorPortLastChange changes.

                      The approximate minimum time for rollover of this
                      counter is 16 hours in a 10Mb/s repeater."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.10, aRunts."
              ::= { rptrMonitorPortEntry 9 }

          rptrMonitorPortCollisions OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "For a clause 9 repeater, this counter is
                      incremented by one for any CarrierEvent signal
                      on any port for which the CollisionEvent signal
                      on this port is asserted.  For a clause 27
                      repeater port the counter increments on entering
                      the Collision Count Increment state of the
                      partition state diagram (fig 27-8 of
                      [IEEE 802.3 Std]).

                      A discontinuity may occur in the value
                      when the value of object
                      rptrMonitorPortLastChange changes.





          Expires August 1996                                  [Page 36]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      The approximate minimum time for rollover of this
                      counter is 16 hours in a 10Mb/s repeater."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.11, aCollisions."
              ::= { rptrMonitorPortEntry 10 }

          rptrMonitorPortLateEvents OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "For a clause 9 repeater port, this counter is
                      incremented by one for each CarrierEvent
                      on this port in which the CollIn(X)
                      variable transitions to the value SQE (Ref:
                      9.6.6.2, IEEE 802.3 Std) while the
                      ActivityDuration is greater than the
                      LateEventThreshold.  For a clause 27 repeater
                      port, this counter is incremented by one on
                      entering the Collision Count Increment state
                      of the  partition state diagram (fig 27-8)
                      while the  ActivityDuration is greater than
                      the LateEvent- Threshold.  Such a CarrierEvent
                      is counted twice, as both a collision and as a
                      lateEvent.

                      The LateEventThreshold is greater than 480 bit
                      times and less than 565 bit times.
                      LateEventThreshold has tolerances included to
                      permit an implementation to build a single
                      threshold to serve as both the LateEventThreshold
                      and ValidPacketMinTime threshold.

                      A discontinuity may occur in the value
                      when the value of object
                      rptrMonitorPortLastChange changes.

                      The approximate minimum time for rollover of this
                      counter is 81 hours in a 10Mb/s repeater."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.12, aLateEvents."
              ::= { rptrMonitorPortEntry 11 }

          rptrMonitorPortVeryLongEvents OBJECT-TYPE
              SYNTAX      Counter32





          Expires August 1996                                  [Page 37]


          Internet Draft        802.3 Repeater MIB      14 February 1996


              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "For a clause 9 repeater port, this counter
                      is incremented by one for each CarrierEvent
                      whose ActivityDuration is greater than the
                      MAU Jabber Lockup Protection timer TW3
                      (Ref: 9.6.1 & 9.6.5, IEEE 802.3 Std).

                      For a clause 27 repeater port, this counter
                      is incremented by one on entry to the
                      Rx Jabber state of the receiver timer state
                      diagram (fig 27-7).  Other counters may
                      be incremented as appropriate.

                      A discontinuity may occur in the value
                      when the value of object
                      rptrMonitorPortLastChange changes."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.13, aVeryLongEvents."
              ::= { rptrMonitorPortEntry 12 }

          rptrMonitorPortDataRateMismatches OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This counter is incremented by one for each
                      frame received by this port that meets all
                      of the conditions required by only one of the
                      following two measurement methods:

                      Measurement method A:  1) The CollisionEvent
                      signal is not asserted (10Mb/s operation) or
                      the Collision Count Increment state of the
                      partition state diagram (fig 27-8 of
                      [IEEE 802.3 Std]) has not been entered
                      (100Mb/s operation).  2) The ActivityDuration
                      is greater than ValidPacketMinTime.  3) The
                      frequency (data rate) is detectably mismatched
                      from the local transmit frequency.

                      Measurement method B:  1) The CollisionEvent
                      signal is not asserted (10Mb/s operation)
                      or the Collision Count Increment state of the





          Expires August 1996                                  [Page 38]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      partition state diagram (fig 27-8 of
                      [IEEE 802.3 Std]) has not been entered
                      (100Mb/s operation).  2) The OctetCount is
                      greater than 63.  3) The frequency (data
                      rate) is detectably mismatched from the local
                      transmit frequency.  The exact degree of
                      mismatch is vendor specific and is to be
                      defined by the vendor for conformance testing.

                      When this event occurs, other counters whose
                      increment conditions were satisfied may or may not
                      also be incremented, at the implementor's
                      discretion.  Whether or not the repeater was able
                      to maintain data integrity is beyond the scope of
                      this standard.

                      A discontinuity may occur in the value
                      when the value of object
                      rptrMonitorPortLastChange changes."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.14, aDataRateMismatches."
              ::= { rptrMonitorPortEntry 13 }

          rptrMonitorPortAutoPartitions OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This counter is incremented by one for
                      each time the repeater has automatically
                      partitioned this port.

                      The conditions that cause a clause 9
                      repeater port to partition are specified in
                      the partition state diagram in clause 9 of
                      [IEEE 802.3 Std].  They are not differentiated
                      here.  A clause 27 repeater port partitions
                      on entry to the Partition Wait state of the
                      partition state diagram (fig 27-8 in
                      [IEEE 802.3 Std]).

                      A discontinuity may occur in the value
                      when the value of object
                      rptrMonitorPortLastChange changes."
              REFERENCE





          Expires August 1996                                  [Page 39]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      "[IEEE 802.3 Mgt], 30.4.3.1.15, aAutoPartitions."
              ::= { rptrMonitorPortEntry 14 }

          rptrMonitorPortTotalErrors OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The total number of errors which have occurred on
                      this port.  This counter is the summation of the
                      values of other error counters (for the same
                      port), namely:

                          rptrMonitorPortFCSErrors,
                          rptrMonitorPortAlignmentErrors,
                          rptrMonitorPortFrameTooLongs,
                          rptrMonitorPortShortEvents,
                          rptrMonitorPortLateEvents,
                          rptrMonitorPortVeryLongEvents, and
                          rptrMonitorPortDataRateMismatches.

                      This counter is redundant in the sense that it is
                      the summation of information already available
                      through other objects.  However, it is included
                      specifically because the regular retrieval of this
                      object as a means of tracking the health of a port
                      provides a considerable optimization of network
                      management traffic over the otherwise necessary
                      retrieval of the summed counters.

                      Note that rptrMonitorPortRunts is not included
                      in this total; this is because runts usually
                      indicate collision fragments, a normal network
                      event.

                      [Editor's note:  This sum does not include the
                      value of the rptrMonitorPortSymbolErrors object.
                      Perhaps we should deprecate it and define a new
                      PortTotalErrors object which does.  However, we
                      may need to address the rollover issue in that
                      case.]

                      A discontinuity may occur in the value
                      when the value of object
                      rptrMonitorPortLastChange changes."





          Expires August 1996                                  [Page 40]


          Internet Draft        802.3 Repeater MIB      14 February 1996


              ::= { rptrMonitorPortEntry 15 }

          rptrMonitorPortLastChange OBJECT-TYPE
              SYNTAX      TimeStamp
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The value of sysUpTime when the last of
                      the following occurred:
                        1) the agent cold- or warm-started;
                        2) the row for the port was created
                           (such as when a device or module was added
                            to the system); or
                        3) any condition that would cause one of
                           the counters for the row to experience
                           a discontinuity."
              ::= { rptrMonitorPortEntry 16 }

          rptrMonitor100PortTable OBJECT-TYPE
              SYNTAX      SEQUENCE OF RptrMonitor100PortEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "Table of additional performance and error
                      statistics for 100Mb/s ports, above and
                      beyond those parameters that apply to both
                      10 and 100Mbps ports.  Entries exist only for
                      ports attached to 100Mbps repeaters.  This
                      table augments the rptrMonitorPortTable.

                      The columnar object rptrMonitorPortLastChange
                      is used to indicate possible discontinuities
                      of counter type columnar objects in this table."
              ::= { rptrMonitorPortInfo 2 }

          rptrMonitor100PortEntry OBJECT-TYPE
              SYNTAX      RptrMonitor100PortEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "An entry in the table, containing performance
                      and error statistics for a single 100Mb/s port."
              AUGMENTS  { rptrMonitorPortEntry }
              ::= { rptrMonitor100PortTable 1 }






          Expires August 1996                                  [Page 41]


          Internet Draft        802.3 Repeater MIB      14 February 1996


          RptrMonitor100PortEntry ::=
              SEQUENCE {
                  rptrMonitorPortIsolates
                      Counter32,
                  rptrMonitorPortSymbolErrors
                      Counter32,
                  rptrMonitorPortUpper32Octets
                      Counter32,
                  rptrMonitorPortHCReadableOctets
                      Counter64
              }

          rptrMonitorPortIsolates OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This counter is incremented by one each time that
                      the repeater port automatically isolates as a
                      consequence of false carrier events.  The conditions
                      which cause a port to automatically isolate are
                      defined by the transition from the False Carrier
                      state to the Link Unstable state of the carrier
                      integrity state diagram (figure 27-9)
                      [IEEE 802.3 Standard].

                      Note:  Isolates do not affect the value of
                      the PortOperStatus object.

                      A discontinuity may occur in the value
                      when the value of object
                      rptrMonitorPortLastChange changes."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.16, aIsolates."
              ::= { rptrMonitor100PortEntry 1 }

          rptrMonitorPortSymbolErrors OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This counter is incremented by one each time when
                      valid length packet was received at the port and
                      there was at least one occurrence of an invalid
                      data symbol. This can increment only once per valid





          Expires August 1996                                  [Page 42]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      carrier event. A collision presence at any port of
                      the repeater containing port N, will not cause this
                      attribute to increment.

                      A discontinuity may occur in the value
                      when the value of object
                      rptrMonitorPortLastChange changes.

                      The approximate minimum time for rollover of this
                      counter is 7.4 hours at 100Mb/s."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.17,
                      aSymbolErrorDuringPacket."
              ::= { rptrMonitor100PortEntry 2 }

          rptrMonitorPortUpper32Octets OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This object is the number of octets contained in
                      valid frames that have been received on this port,
                      modulo 2**32.  That is, it contains the upper 32
                      bits of a 64-bit octets counter, of which the
                      lower 32 bits are contained in the
                      rptrMonitorPortReadableOctets object.

                      This two-counter mechanism is provided for those
                      network management protocols that do not support
                      64-bit counters (e.g. SNMP V1) and are used to
                      manage a repeater type of 100Mb/s.

                      A discontinuity may occur in the value
                      when the value of object
                      rptrMonitorPortLastChange changes."
              ::= { rptrMonitor100PortEntry 3 }

          rptrMonitorPortHCReadableOctets OBJECT-TYPE
              SYNTAX      Counter64
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This object is the number of octets contained in
                      valid frames that have been received on this port.
                      This counter is incremented by OctetCount for each





          Expires August 1996                                  [Page 43]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      frame received on this port which has been
                      determined to be a readable frame (i.e., including
                      FCS octets but excluding framing bits and dribble
                      bits).

                      This statistic provides an indicator of the total
                      data transferred.

                      This counter is a 64-bit version of rptrMonitor-
                      PortReadableOctets. It should be used by network
                      management protocols which suppport 64-bit counters
                      (e.g. SNMPv2).

                      A discontinuity may occur in the value
                      when the value of object
                      rptrMonitorPortLastChange changes."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.5, aReadableOctets."
              ::= { rptrMonitor100PortEntry 4 }


          -- New version of statistics at the repeater level.
          --
          -- Statistics objects for each managed repeater
          -- in the system.

          rptrMonTable OBJECT-TYPE
              SYNTAX      SEQUENCE OF RptrMonEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "A table of information about each
                      non-trivial repeater.  The number of entries
                      in this table is the same as the number of
                      entries in the rptrInfoTable.

                      The columnar object rptrInfoLastChange is
                      used to indicate possible discontinuities of
                      counter type columnar objects in this table."
              ::= { rptrMonitorAllRptrInfo 1 }

          rptrMonEntry OBJECT-TYPE
              SYNTAX      RptrMonEntry
              MAX-ACCESS  not-accessible
              STATUS      current





          Expires August 1996                                  [Page 44]


          Internet Draft        802.3 Repeater MIB      14 February 1996


              DESCRIPTION
                      "An entry in the table, containing information
                      about a single non-trivial repeater."
              AUGMENTS  { rptrInfoEntry }
              ::= { rptrMonTable 1 }

          RptrMonEntry ::=
              SEQUENCE {
                  rptrMonTxCollisions
                      Counter32,
                  rptrMonTotalFrames
                      Counter32,
                  rptrMonTotalErrors
                      Counter32,
                  rptrMonTotalOctets
                      Counter32
              }

          rptrMonTxCollisions OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "For a clause 9 (10Mb/s) repeater, this counter
                      is incremented every time the repeater state
                      machine enters the TRANSMIT COLLISION state
                      from any state other than ONE PORT LEFT
                      (Ref: Fig 9-2 [IEEE 802.3 Std]).

                      For a clause 27 repeater, this counter is
                      incremented every time the repeater core state
                      diagram enters the Jam state as a result of
                      Activity(ALL) > 1 (fig 27-2 [IEEE 802.3 Std]).

                      The approximate minimum time for rollover of this
                      counter is 16 hours in a 10Mb/s repeater and 1.6
                      hours in a 100Mb/s repeater."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.1.1.8, aTransmitCollisions"
              ::= { rptrMonEntry 1 }

          rptrMonTotalFrames OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current





          Expires August 1996                                  [Page 45]


          Internet Draft        802.3 Repeater MIB      14 February 1996


              DESCRIPTION
                      "The number of frames of valid frame length
                      that have been received on the ports in this repeater
                      and for which the FCSError and CollisionEvent
                      signals were not asserted.  If an implementation
                      can not obtain a count of frames as seen by
                      the repeater itself, this counter may be
                      implemented as the summation of the values of the
                      rptrMonitorPortReadableFrames counters for all of
                      the ports in the repeater.

                      This statistic provides one of the parameters
                      necessary for obtaining the packet error rate.
                      The approximate minimum time for rollover of this
                      counter is 80 hours in a 10Mb/s repeater."
              ::= { rptrMonEntry 3 }

          rptrMonTotalErrors OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The total number of errors which have occurred on
                      all of the ports in this repeater.  The errors
                      included in this count are the same as those listed
                      for the rptrMonitorPortTotalErrors counter.  If an
                      implementation can not obtain a count of these
                      errors as seen by the repeater itself, this counter
                      may be implemented as the summation of the values of
                      the rptrMonitorPortTotalErrors counters for all of
                      the ports in the repeater."
              ::= { rptrMonEntry 4 }

          rptrMonTotalOctets OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The total number of octets contained in the valid
                      frames that have been received on the ports in
                      this group.  If an implementation can not obtain
                      a count of octets as seen by the repeater itself,
                      this counter may be the summation of the
                      values of the rptrMonitorPortReadableOctets
                      counters for all of the ports in the group.





          Expires August 1996                                  [Page 46]


          Internet Draft        802.3 Repeater MIB      14 February 1996



                      This statistic provides an indicator of the total
                      data transferred.  The approximate minimum time
                      for rollover of this counter in a 10Mb/s repeater
                      is 58 minutes divided by the number of ports in
                      the repeater.

                      For 100Mb/s repeaters processing traffic at a
                      maximum rate, this counter can roll over in less
                      than 6 minutes divided by the number of ports in
                      the repeater.  Since that amount of time could
                      be less than a management station's poll cycle
                      time, in order to avoid a loss of information a
                      management station is advised to also poll the
                      rptrMonUpper32TotalOctets object, or to use the
                      64-bit counter defined by rptrMonHCTotalOctets
                      instead of the two 32-bit counters."
              ::= { rptrMonEntry 5 }

          rptrMon100Table OBJECT-TYPE
              SYNTAX      SEQUENCE OF RptrMon100Entry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "A table of additional information about each
                      100Mb/s repeater, augmenting the entries in
                      the rptrMonTable.  Entries exist in this table
                      only for 100Mb/s repeaters.

                      The columnar object rptrInfoLastChange is
                      used to indicate possible discontinuities of
                      counter type columnar objects in this table."
              ::= { rptrMonitorAllRptrInfo 2 }

          rptrMon100Entry OBJECT-TYPE
              SYNTAX      RptrMon100Entry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "An entry in the table, containing information
                      about a single 100Mbps repeater."
              AUGMENTS  { rptrInfoEntry }
              ::= { rptrMon100Table 1 }

          RptrMon100Entry ::=





          Expires August 1996                                  [Page 47]


          Internet Draft        802.3 Repeater MIB      14 February 1996


              SEQUENCE {
                  rptrMonUpper32TotalOctets
                      Counter32,
                  rptrMonHCTotalOctets
                      Counter64
              }

          rptrMonUpper32TotalOctets OBJECT-TYPE
              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The total number of octets contained in the valid
                      frames that have been received on the ports in
                      this repeater, modulo 2**32.  That is, it contains
                      the upper 32 bits of a 64-bit counter, of which
                      the lower 32 bits are contained in the
                      rptrMonTotalOctets object.  If an implementation
                      can not obtain a count of octets as seen
                      by the repeater itself, the 64-bit value
                      may be the summation of the values of the
                      rptrMonitorPortReadableOctets counters combined
                      with the corresponding rptrMonitorPortUpper32Octets
                      counters for all of the ports in the repeater.

                      This statistic provides an indicator of the total
                      data transferred within the repeater.

                      This two-counter mechanism is provided for those
                      network management protocols that do not support
                      64-bit counters (e.g. SNMP V1) and are used to
                      manage a repeater type of 100Mb/s."
              ::= { rptrMon100Entry 1 }

          rptrMonHCTotalOctets OBJECT-TYPE
              SYNTAX      Counter64
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The total number of octets contained in the valid
                      frames that have been received on the ports in
                      this group.  If a implementation can not obtain
                      a count of octets as seen by the repeater itself,
                      this counter may be the summation of the
                      values of the rptrMonitorPortReadableOctets





          Expires August 1996                                  [Page 48]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      counters for all of the ports in the group.

                      This statistic provides an indicator of the total
                      data transferred.

                      This counter is a 64-bit (high-capacity) version
                      of rptrMonUpper32TotalOctets and rptrMonTotalOctets.
                      It should be used by network management protocols
                      which support 64-bit counters (e.g. SNMPv2). "
              ::= { rptrMon100Entry 2 }


          --
          -- The Port Address Tracking Table
          --

          rptrAddrTrackTable OBJECT-TYPE
              SYNTAX      SEQUENCE OF RptrAddrTrackEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "Table of address mapping information about the
                      ports."
              ::= { rptrAddrTrackPortInfo 1 }

          rptrAddrTrackEntry OBJECT-TYPE
              SYNTAX      RptrAddrTrackEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "An entry in the table, containing address mapping
                      information about a single port."
              INDEX    { rptrAddrTrackGroupIndex, rptrAddrTrackPortIndex }
              ::= { rptrAddrTrackTable 1 }

          RptrAddrTrackEntry ::=
              SEQUENCE {
                  rptrAddrTrackGroupIndex
                      INTEGER,
                  rptrAddrTrackPortIndex
                      INTEGER,
                  rptrAddrTrackLastSourceAddress     -- DEPRECATED OBJECT
                      MacAddress,
                  rptrAddrTrackSourceAddrChanges
                      Counter32,





          Expires August 1996                                  [Page 49]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                  rptrAddrTrackNewLastSrcAddress
                      OptMacAddr,
                  rptrAddrTrackCapacity
                      Integer32
              }

          rptrAddrTrackGroupIndex OBJECT-TYPE
              SYNTAX      INTEGER (1..2147483647)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This object identifies the group containing the
                      port for which this entry contains information."
              ::= { rptrAddrTrackEntry 1 }

          rptrAddrTrackPortIndex OBJECT-TYPE
              SYNTAX      INTEGER (1..2147483647)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This object identifies the port within the group
                      for which this entry contains information."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.1, aPortID."
              ::= { rptrAddrTrackEntry 2 }

          rptrAddrTrackLastSourceAddress OBJECT-TYPE
              SYNTAX      MacAddress
              MAX-ACCESS  read-only
              STATUS      deprecated
              DESCRIPTION
                      "This object is the SourceAddress of the last
                      readable frame (i.e., counted by
                      rptrMonitorPortReadableFrames) received by this
                      port.

                      This object has been deprecated because its value
                      is undefined when no frames have been observed on
                      this port.  The replacement object is
                      rptrAddrTrackNewLastSrcAddress."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.18, aLastSourceAddress."
              ::= { rptrAddrTrackEntry 3 }

          rptrAddrTrackSourceAddrChanges OBJECT-TYPE





          Expires August 1996                                  [Page 50]


          Internet Draft        802.3 Repeater MIB      14 February 1996


              SYNTAX      Counter32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This counter is incremented by one for each time
                      that the rptrAddrTrackLastSourceAddress attribute
                      for this port has changed.

                      This may indicate whether a link is connected to a
                      single DTE or another multi-user segment.

                      A discontinuity may occur in the value when the
                      value of object rptrMonitorPortLastChange changes.

                      The approximate minimum time for rollover of this
                      counter is 81 hours in a 10Mb/s repeater."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.19, aSourceAddressChanges."
              ::= { rptrAddrTrackEntry 4 }

          rptrAddrTrackNewLastSrcAddress OBJECT-TYPE
              SYNTAX      OptMacAddr
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This object is the SourceAddress of the last
                      readable frame (i.e., counted by
                      rptrMonitorPortReadableFrames) received by this
                      port.  If no frames have been received by this
                      port since the agent began monitoring the port
                      activity, the agent shall return a string of
                      length zero."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.18, aLastSourceAddress."
              ::= { rptrAddrTrackEntry 5 }

          rptrAddrTrackCapacity OBJECT-TYPE
              SYNTAX      Integer32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The maximum number of addresses that can be
                      detected on this port. This value indicates
                      to the maximum  number of entries in the
                      rptrExtAddrTrackTable relative to this port.





          Expires August 1996                                  [Page 51]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      If this object has the value of 1, the agent
                      implements only the LastSourceAddress mechanism
                      described by RFC 1368 or RFC 1516."
              ::= { rptrAddrTrackEntry 6 }


          -- Table for multiple addresses per port

          rptrExtAddrTrackTable OBJECT-TYPE
              SYNTAX      SEQUENCE OF RptrExtAddrTrackEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "A table to extend the address tracking table (i.e.,
                      rptrAddrTrackTable) with a list of source MAC
                      addresses that were recently received on each port.
                      The number of ports is the same as the number
                      of entries in table rptrPortTable. The number of
                      entries in this table depends on the agent/repeater
                      implementation and the number of different
                      addresses received on each port.

                      The first entry for each port contains
                      the same MAC address that is given by the
                      rptrAddrTrackNewLastSrcAddress for that port.

                      Entries in this table for a particular port are
                      retained when that port is switched from one
                      repeater to another.

                      The ordering of MAC addresses listed for a
                      particular port is implementation dependent."
              ::= { rptrAddrTrackPortInfo 2 }

          rptrExtAddrTrackEntry OBJECT-TYPE
              SYNTAX      RptrExtAddrTrackEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "A row in the table of extended address tracking
                      information for ports. Entries can not be directly
                      created or deleted via SNMP operations."
              INDEX       { rptrAddrTrackGroupIndex,
                            rptrAddrTrackPortIndex,
                            rptrExtAddrTrackMacIndex }





          Expires August 1996                                  [Page 52]


          Internet Draft        802.3 Repeater MIB      14 February 1996


              ::= { rptrExtAddrTrackTable 1 }

          RptrExtAddrTrackEntry ::= SEQUENCE {
              rptrExtAddrTrackMacIndex Integer32,
              rptrExtAddrTrackSourceAddress MacAddress
              }

          rptrExtAddrTrackMacIndex OBJECT-TYPE
              SYNTAX      Integer32 (1..2147483647)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The index of a source MAC address seen on
                      the port."
              ::= { rptrExtAddrTrackEntry 1 }

          rptrExtAddrTrackSourceAddress OBJECT-TYPE
              SYNTAX      MacAddress
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The source MAC address from a readable frame
                      (i.e., counted by rptrMonitorPortReadableFrames)
                      recently received by the port."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.3.1.18, aLastSourceAddress."
              ::= { rptrExtAddrTrackEntry 2 }

          rptrAddrTrackReset OBJECT-TYPE
              SYNTAX      INTEGER {
                            noReset(1),
                            reset(2)
                          }
              MAX-ACCESS  read-write
              STATUS      current
              DESCRIPTION
                      "Setting this object to reset(2) causes
                      the agent to empty the contents of the
                      rptrExtAddrTrackTable.  The contents of
                      the rptrAddrTrackTable are not affected.

                      Setting this object to noReset(1) has no effect.
                      The agent will always return the value noReset(1)
                      when this object is read."
              ::= { rptrAddrTrackPortInfo 3 }





          Expires August 1996                                  [Page 53]


          Internet Draft        802.3 Repeater MIB      14 February 1996


          -- The Repeater Top "N" Port Group

          -- The Repeater Top N Port group is used to prepare reports that
          -- describe a list of ports ordered by one of the statistics in the
          -- Repeater Monitor Port Table.  The statistic chosen by the
          -- management station is sampled over a management
          -- station-specified time interval, making the report rate based.
          -- The management station also specifies the number of ports that
          -- are reported.
          --
          -- The rptrTopNPortControlTable is used to initiate the generation
          -- of a report.  The management station may select the parameters
          -- of such a report, such as which repeater, which statistic, how
          -- many ports, and the start & stop times of the sampling.  When
          -- the report is prepared, entries are created in the
          -- rptrTopNPortTable associated with the relevent
          -- rptrTopNControlEntry.  These entries are static for
          -- each report after it has been prepared.

          -- Note that counter discontinuities may appear in some
          -- implementations if ports' assignment to repeaters changes
          -- during the collection of data for a Top "N" report.
          -- A management application could read the corresponding
          -- rptrMonitorPortLastChange timestamp in order to check
          -- whether a discontinuity occurred.


          rptrTopNPortControlTable OBJECT-TYPE
              SYNTAX      SEQUENCE OF RptrTopNPortControlEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                  "A table of control records for reports on the top `N'
                  ports for the rate of a selected counter. The number
                  of entries depends on the configuration of the agent.
                  The maximum number of entries is implementation
                  dependent."
              ::= { rptrTopNPortInfo 1 }

          rptrTopNPortControlEntry OBJECT-TYPE
              SYNTAX      RptrTopNPortControlEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "A set of parameters that control the creation of a





          Expires August 1996                                  [Page 54]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      report of the top N ports according to several metrics."
              INDEX    { rptrTopNPortControlIndex }
              ::= { rptrTopNPortControlTable 1 }

          RptrTopNPortControlEntry ::= SEQUENCE {
              rptrTopNPortControlIndex
                  Integer32,
              rptrTopNPortRepeaterId
                  Integer32,
              rptrTopNPortRateBase
                  INTEGER,
              rptrTopNPortTimeRemaining
                  Integer32,
              rptrTopNPortDuration
                  Integer32,
              rptrTopNPortRequestedSize
                  Integer32,
              rptrTopNPortGrantedSize
                  Integer32,
              rptrTopNPortStartTime
                  TimeStamp,
              rptrTopNPortOwner
                  OwnerString,
              rptrTopNPortRowStatus
                  RowStatus
          }

          rptrTopNPortControlIndex OBJECT-TYPE
              SYNTAX      Integer32 (1 .. 65535)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "An index that uniquely identifies an entry in the
                      rptrTopNPortControl table.  Each such entry defines
                      one top N report prepared for a repeater or system."
              ::= { rptrTopNPortControlEntry 1 }

          rptrTopNPortRepeaterId OBJECT-TYPE
              SYNTAX      Integer32 (0..2147483647)
              MAX-ACCESS  read-create
              STATUS      current
              DESCRIPTION
                      "Identifies the repeater for which a top N report will
                      be prepared (see rptrInfoId).  If the value of this
                      object is positive, only ports assigned to this repeater





          Expires August 1996                                  [Page 55]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      will be used to form the list in which to order the
                      Top N table.  If this value is zero, all ports will be
                      eligible for inclusion on the list.

                      The value of this object may not be modified if the
                      associated rptrTopNPortRowStatus object is equal to
                      active(1)."
              ::= { rptrTopNPortControlEntry 2 }

          rptrTopNPortRateBase OBJECT-TYPE
              SYNTAX      INTEGER  {
                            rptrMonitorPortReadableFrames(1),
                            rptrMonitorPortReadableOctets(2),
                            rptrMonitorPortFCSErrors(3),
                            rptrMonitorPortAlignmentErrors(4),
                            rptrMonitorPortFrameTooLongs(5),
                            rptrMonitorPortShortEvents(6),
                            rptrMonitorPortRunts(7),
                            rptrMonitorPortCollisions(8),
                            rptrMonitorPortLateEvents(9),
                            rptrMonitorPortVeryLongEvents(10),
                            rptrMonitorPortDataRateMismatches(11),
                            rptrMonitorPortAutoPartitions(12),
                            rptrMonitorPortTotalErrors(13),
                            rptrMonitorPortIsolates(14),
                            rptrMonitorPortSymbolErrors(15)
                          }
              MAX-ACCESS  read-create
              STATUS      current
              DESCRIPTION
                      "The monitored variable, which the rptrTopNPortRate
                      variable is based upon.

                      The value of this object may not be modified if
                      the associated rptrTopNPortRowStatus object has
                      a value of active(1)."
              ::= { rptrTopNPortControlEntry 3 }

          rptrTopNPortTimeRemaining OBJECT-TYPE
              SYNTAX      Integer32 (0..2147483647)
              MAX-ACCESS  read-create
              STATUS      current
              DESCRIPTION
                      "The number of seconds left in the report
                      currently being collected.  When this object





          Expires August 1996                                  [Page 56]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      is modified by the management station, a new
                      collection is started, possibly aborting a
                      currently running report.  The new value is
                      used as the requested duration of this report,
                      which is loaded into the associated
                      rptrTopNPortDuration object.

                      When this object is set to a non-zero value,
                      any associated rptrTopNPortEntries shall be
                      made inaccessible by the agent.  While the value
                      of this object is non-zero, it decrements by one
                      per second until it reaches zero.  During this
                      time, all associated rptrTopNPortEntries shall
                      remain inaccessible.  At the time that this object
                      decrements to zero, the report is made accessible
                      in the rptrTopNPortTable.  Thus, the rptrTopNPort
                      table needs to be created only at the end of the
                      collection interval."
              DEFVAL { 0 }
              ::= { rptrTopNPortControlEntry 4 }

          rptrTopNPortDuration OBJECT-TYPE
              SYNTAX      Integer32 (0..2147483647)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The number of seconds that this report has
                      collected during the last sampling interval,
                      or if this report is currently being collected,
                      the number of seconds that this report is being
                      collected during this sampling interval.

                      When the associated rptrTopNPortTimeRemaining
                      object is set, this object shall be set by the
                      agent to the same value and shall not be modified
                      until the next time the rptrTopNPortTimeRemaining
                      is set.

                      This value shall be zero if no reports have been
                      requested for this rptrTopNPortControlEntry."
               ::= { rptrTopNPortControlEntry 5 }

          rptrTopNPortRequestedSize OBJECT-TYPE
              SYNTAX      Integer32
              MAX-ACCESS  read-create





          Expires August 1996                                  [Page 57]


          Internet Draft        802.3 Repeater MIB      14 February 1996


              STATUS      current
              DESCRIPTION
                      "The maximum number of repeater ports requested
                      for the Top N Table.

                      When this object is created or modified, the
                      agent should set rptrTopNPortGrantedSize as close
                      to this object as is possible for the particular
                      implementation and available resources."
              DEFVAL { 10 }
              ::= { rptrTopNPortControlEntry 6 }

          rptrTopNPortGrantedSize OBJECT-TYPE
              SYNTAX      Integer32 (0..65535)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The maximum number of repeater ports in the
                      top N table.

                      When the associated rptrTopNPortRequestedSize object is
                      created or modified, the agent should set this object as
                      closely to the requested value as is possible for the
                      particular implementation and available resources.  The
                      agent must not lower this value except as a result of a
                      set to the associated rptrTopNPortRequestedSize object."
              ::= { rptrTopNPortControlEntry 7 }

          rptrTopNPortStartTime OBJECT-TYPE
              SYNTAX      TimeStamp
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The value of sysUpTime when this top N report was
                      last started.  In other words, this is the time that
                      the associated rptrTopNPortTimeRemaining object was
                      modified to start the requested report."
              ::= { rptrTopNPortControlEntry 8 }

          rptrTopNPortOwner OBJECT-TYPE
              SYNTAX      OwnerString
              MAX-ACCESS  read-create
              STATUS      current
              DESCRIPTION
                      "The entity that configured this entry and is





          Expires August 1996                                  [Page 58]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      using the resources assigned to it."
              ::= { rptrTopNPortControlEntry 9 }

          rptrTopNPortRowStatus OBJECT-TYPE
              SYNTAX      RowStatus
              MAX-ACCESS  read-create
              STATUS      current
              DESCRIPTION
                     "The status of this row."
              ::= { rptrTopNPortControlEntry 10 }


          -- Top "N" reports

          rptrTopNPortTable OBJECT-TYPE
              SYNTAX      SEQUENCE OF RptrTopNPortEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "A table of reports for the top `N' ports based on
                      setting of associated control table entries. The
                      maximum number of entries depends on the number
                      of entries in table rptrTopNPortControlTable and
                      the value of object rptrTopNPortGrantedSize for
                      each entry.

                      For each entry in the rptrTopNPortControlTable,
                      repeater ports with the highest value of
                      rptrTopNPortRate shall be placed in this table
                      in decreasing order of that rate until there is
                      no more room or until there are no more ports."
              ::= { rptrTopNPortInfo 2 }

          rptrTopNPortEntry OBJECT-TYPE
              SYNTAX      RptrTopNPortEntry
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "A set of statistics for a repeater port that is
                      part of a top N report."
              INDEX    { rptrTopNPortControlIndex,
                         rptrTopNPortIndex }
              ::= { rptrTopNPortTable 1 }

          RptrTopNPortEntry ::= SEQUENCE {





          Expires August 1996                                  [Page 59]


          Internet Draft        802.3 Repeater MIB      14 February 1996


              rptrTopNPortIndex
                  Integer32,
              rptrTopNPortGroupIndex
                  Integer32,
              rptrTopNPortPortIndex
                  Integer32,
              rptrTopNPortRate
                  Gauge32
          }

          rptrTopNPortIndex OBJECT-TYPE
              SYNTAX      Integer32 (1..65535)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "An index that uniquely identifies an entry in
                      the rptrTopNPort table among those in the same
                      report.  This index is between 1 and N, where N
                      is the number of entries in this report.  Increasing
                      values of rptrTopNPortIndex shall be assigned to
                      entries with decreasing values of rptrTopNPortRate
                      until index N is assigned to the entry with the
                      lowest value of rptrTopNPortRate or there are no
                      more rptrTopNPortEntries.

                      No ports are included in a report where their
                      value of rptrTopNPortRate would be zero."
              ::= { rptrTopNPortEntry 1 }

          rptrTopNPortGroupIndex OBJECT-TYPE
              SYNTAX      Integer32  (1..2147483647)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "This object identifes the group containing
                      the port for this entry. (See also object
                      type rptrGroupIndex.)"
              ::= { rptrTopNPortEntry 2 }

          rptrTopNPortPortIndex OBJECT-TYPE
              SYNTAX      Integer32 (1..2147483647)
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                  "The index of the repeater port.





          Expires August 1996                                  [Page 60]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                  (See object type rptrPortIndex.)"
              ::= { rptrTopNPortEntry 3 }

          rptrTopNPortRate OBJECT-TYPE
              SYNTAX      Gauge32
              MAX-ACCESS  read-only
              STATUS      current
              DESCRIPTION
                      "The amount of change in the selected variable
                      during this sampling interval for the identified
                      port.  The selected variable is that port's
                      instance of the object selected by
                      rptrTopNPortRateBase."
              ::= { rptrTopNPortEntry 4 }


          -- Notifications for use by Repeaters

          rptrHealth NOTIFICATION-TYPE
              OBJECTS     { rptrOperStatus }
              STATUS      deprecated
              DESCRIPTION
                      "In a system containing a single managed repeater,
                      the rptrHealth notification conveys information
                      related to the operational status of the repeater.
                      It is sent either when the value of
                      rptrOperStatus changes, or upon completion of a
                      non-disruptive test.

                      The rptrHealth notification must contain the
                      rptrOperStatus object.  The agent may optionally
                      include the rptrHealthText object in the varBind
                      list.  See the rptrOperStatus and rptrHealthText
                      objects for descriptions of the information that
                      is sent.

                      The agent must throttle the generation of
                      consecutive rptrHealth traps so that there is at
                      least a five-second gap between traps of this
                      type.  When traps are throttled, they are dropped,
                      not queued for sending at a future time.  (Note
                      that 'generating' a trap means sending to all
                      configured recipients.)"
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.1.3.1, nRepeaterHealth





          Expires August 1996                                  [Page 61]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      notification."
              ::= { snmpDot3RptrMgt 0 1 }

          rptrGroupChange NOTIFICATION-TYPE
              OBJECTS     { rptrGroupIndex }
              STATUS      deprecated
              DESCRIPTION
                      "In a system containing a single managed repeater,
                      this notification is sent when a change occurs in the
                      group structure of the repeater.  This occurs only
                      when a group is logically or physically removed
                      from or added to a repeater.  The varBind list
                      contains the identifier of the group that was
                      removed or added.

                      The agent must throttle the generation of
                      consecutive rptrGroupChange traps for the same
                      group so that there is at least a five-second gap
                      between traps of this type.  When traps are
                      throttled, they are dropped, not queued for
                      sending at a future time.  (Note that 'generating'
                      a trap means sending to all configured
                      recipients.)"
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.1.3.3, nGroupMapChange
                      notification."
              ::= { snmpDot3RptrMgt 0 2 }

          rptrResetEvent NOTIFICATION-TYPE
              OBJECTS     { rptrOperStatus }
              STATUS      deprecated
              DESCRIPTION
                      "In a system containing a single managed repeater-unit,
                      the rptrResetEvent notification conveys information
                      related to the operational status of the repeater.
                      This trap is sent on completion of a repeater
                      reset action.  A repeater reset action is defined
                      as an a transition to the START state of Fig 9-2
                      in section 9 [IEEE 802.3 Std], when triggered by a
                      management command (e.g., an SNMP Set on the
                      rptrReset object).

                      The agent must throttle the generation of
                      consecutive rptrResetEvent traps so that there is
                      at least a five-second gap between traps of this





          Expires August 1996                                  [Page 62]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      type.  When traps are throttled, they are dropped,
                      not queued for sending at a future time.  (Note
                      that 'generating' a trap means sending to all
                      configured recipients.)

                      The rptrResetEvent trap is not sent when the agent
                      restarts and sends an SNMP coldStart or warmStart
                      trap.  However, it is recommended that a repeater
                      agent send the rptrOperStatus object as an
                      optional object with its coldStart and warmStart
                      trap PDUs.

                      The rptrOperStatus object must be included in the
                      varbind list sent with this trap.  The agent may
                      optionally include the rptrHealthText object as
                      well."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.1.3.2, nRepeaterReset
                      notification."
              ::= { snmpDot3RptrMgt 0 3 }


          -- Notifications for repeaters in a multiple-repeater implementation.
          -- An implementation may send either the single-repeater OR
          -- multiple-repeater version of these notifications (1 or 4; 2 or 5)
          -- but not both.

          rptrInfoHealth NOTIFICATION-TYPE
              OBJECTS     { rptrInfoOperStatus }
              STATUS      current
              DESCRIPTION
                      "In a system containing multiple managed repeaters,
                      the rptrInfoHealth notification conveys information
                      related to the operational status of a repeater.
                      It is sent either when the value of rptrInfoOperStatus
                      changes, or upon completion of a non-disruptive test.

                      The agent must throttle the generation of
                      consecutive rptrInfoHealth notifications for
                      the same repeater so that there is at least
                      a five-second gap between notifications of this type.
                      When notifications are throttled, they are dropped,
                      not queued for sending at a future time.  (Note
                      that 'generating' a notification means sending
                      to all configured recipients.)"





          Expires August 1996                                  [Page 63]


          Internet Draft        802.3 Repeater MIB      14 February 1996


              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.1.3.1, nRepeaterHealth
                      notification."
              ::= { snmpDot3RptrMgt 0 4 }

          rptrInfoResetEvent NOTIFICATION-TYPE
              OBJECTS     { rptrInfoOperStatus }
              STATUS      current
              DESCRIPTION
                      "In a system containing multiple managed
                      repeaters, the rptrInfoResetEvent notification
                      conveys information related to the operational
                      status of a repeater. This notification is sent
                      on completion of a repeater reset action.  A
                      repeater reset action is defined as a transition
                      to the START state of Fig 9-2 in section 9 of
                      [IEEE 802.3 Std], when triggered by a management
                      command (e.g., an SNMP Set on the rptrInfoReset
                      object).

                      The agent must throttle the generation of
                      consecutive rptrInfoResetEvent notifications for
                      a single repeater so that there is at least
                      a five-second gap between notifications of
                      this type.  When notifications are throttled,
                      they are dropped, not queued for sending at
                      a future time.  (Note that 'generating' a
                      notification means sending to all configured
                      recipients.)

                      The rptrInfoResetEvent trap is not sent when the
                      agent restarts and sends an SNMP coldStart or
                      warmStart trap.  However, it is recommended that
                      a repeater agent send the rptrInfoOperStatus
                      object as an optional object with its coldStart
                      and warmStart trap PDUs."
              REFERENCE
                      "[IEEE 802.3 Mgt], 30.4.1.3.2, nRepeaterReset
                      notification."
              ::= { snmpDot3RptrMgt 0 5 }


          -- Conformance information

          snmpRptrModConf





          Expires August 1996                                  [Page 64]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                  OBJECT IDENTIFIER ::= { snmpRptrMod 1 }
            snmpRptrModCompls
                  OBJECT IDENTIFIER ::= { snmpRptrModConf 1 }
            snmpRptrModObjGrps
                  OBJECT IDENTIFIER ::= { snmpRptrModConf 2 }
            snmpRptrModNotGrps
                  OBJECT IDENTIFIER ::= { snmpRptrModConf 3 }


          -- Object groups

          snmpRptrGrpBasic OBJECT-GROUP
              OBJECTS     { rptrGroupCapacity,
                            rptrOperStatus,
                            rptrHealthText,
                            rptrReset,
                            rptrNonDisruptTest,
                            rptrTotalPartitionedPorts,

                            rptrGroupIndex,
                            rptrGroupDescr,
                            rptrGroupObjectID,
                            rptrGroupOperStatus,
                            rptrGroupLastOperStatusChange,
                            rptrGroupPortCapacity,

                            rptrPortGroupIndex,
                            rptrPortIndex,
                            rptrPortAdminStatus,
                            rptrPortAutoPartitionState,
                            rptrPortOperStatus }
              STATUS      deprecated
              DESCRIPTION
                  "Basic group from RFCs 1368 and 1516.

                  NOTE: this object group is DEPRECATED and replaced
                        with snmpRptrGrpBasicRS."
              ::= { snmpRptrModObjGrps 1 }

          snmpRptrGrpMonitor OBJECT-GROUP
              OBJECTS     { rptrMonitorTransmitCollisions,

                            rptrMonitorGroupIndex,
                            rptrMonitorGroupTotalFrames,
                            rptrMonitorGroupTotalOctets,





          Expires August 1996                                  [Page 65]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                            rptrMonitorGroupTotalErrors,

                            rptrMonitorPortGroupIndex,
                            rptrMonitorPortIndex,
                            rptrMonitorPortReadableFrames,
                            rptrMonitorPortReadableOctets,
                            rptrMonitorPortFCSErrors,
                            rptrMonitorPortAlignmentErrors,
                            rptrMonitorPortFrameTooLongs,
                            rptrMonitorPortShortEvents,
                            rptrMonitorPortRunts,
                            rptrMonitorPortCollisions,
                            rptrMonitorPortLateEvents,
                            rptrMonitorPortVeryLongEvents,
                            rptrMonitorPortDataRateMismatches,
                            rptrMonitorPortAutoPartitions,
                            rptrMonitorPortTotalErrors }
              STATUS      deprecated
              DESCRIPTION
                  "Monitor group from RFCs 1368 and 1516.

                  NOTE: this object group is DEPRECATED and replaced
                        with snmpRptrGrpMonitorRS."
              ::= { snmpRptrModObjGrps 2 }

          snmpRptrGrpAddrTrack OBJECT-GROUP
              OBJECTS     { rptrAddrTrackGroupIndex,
                            rptrAddrTrackPortIndex,
                            rptrAddrTrackLastSourceAddress,
                            rptrAddrTrackSourceAddrChanges }
              STATUS      obsolete
              DESCRIPTION
                  "Address tracking group from RFC 1368.

                  NOTE: this object group is OBSOLETE and replaced
                        with snmpRptrGrpAddrTrackNewSrcAddr."
              ::= { snmpRptrModObjGrps 3 }

          snmpRptrGrpAddrTrackNewSrcAddr OBJECT-GROUP
              OBJECTS     { rptrAddrTrackGroupIndex,
                            rptrAddrTrackPortIndex,
                            rptrAddrTrackLastSourceAddress,
                            rptrAddrTrackSourceAddrChanges,
                            rptrAddrTrackNewLastSrcAddress }
              STATUS      deprecated





          Expires August 1996                                  [Page 66]


          Internet Draft        802.3 Repeater MIB      14 February 1996


              DESCRIPTION
                  "Address tracking group from RFC 1516.

                  NOTE: this object group is DEPRECATED and
                        replaced with snmpRptrGrpAddrTrackRS."
              ::= { snmpRptrModObjGrps 4 }

          snmpRptrGrpBasicRS OBJECT-GROUP
              OBJECTS     { rptrGroupIndex,
                            rptrGroupDescr,
                            rptrGroupObjectID,
                            rptrGroupOperStatus,
                            rptrGroupLastOperStatusChange,
                            rptrGroupPortCapacity,

                            rptrPortGroupIndex,
                            rptrPortIndex,
                            rptrPortAdminStatus,
                            rptrPortAutoPartitionState,
                            rptrPortOperStatus,
                            rptrPortRptrId,

                            rptrInfoId,
                            rptrInfoRptrType,
                            rptrInfoOperStatus,
                            rptrInfoReset,
                            rptrInfoNonDisruptTest,
                            rptrInfoPartitionedPorts,
                            rptrInfoLastChange }
              STATUS      current
              DESCRIPTION
                  "Basic group for a system with one or more
                  repeater-units in restart version of the MIB
                  module."
              ::= { snmpRptrModObjGrps 5 }

          snmpRptrGrpMonitorRS OBJECT-GROUP
              OBJECTS     { rptrMonitorPortGroupIndex,
                            rptrMonitorPortIndex,
                            rptrMonitorPortReadableFrames,
                            rptrMonitorPortReadableOctets,
                            rptrMonitorPortFCSErrors,
                            rptrMonitorPortAlignmentErrors,
                            rptrMonitorPortFrameTooLongs,
                            rptrMonitorPortShortEvents,





          Expires August 1996                                  [Page 67]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                            rptrMonitorPortRunts,
                            rptrMonitorPortCollisions,
                            rptrMonitorPortLateEvents,
                            rptrMonitorPortVeryLongEvents,
                            rptrMonitorPortDataRateMismatches,
                            rptrMonitorPortAutoPartitions,
                            rptrMonitorPortTotalErrors,
                            rptrMonitorPortLastChange,

                            rptrMonTxCollisions,
                            rptrMonTotalFrames,
                            rptrMonTotalErrors,
                            rptrMonTotalOctets }
              STATUS      current
              DESCRIPTION
                  "Monitor group for a system with one or more
                  repeater-units in restart version of the MIB
                  module."
              ::= { snmpRptrModObjGrps 6 }

          snmpRptrGrpMonitor100RS OBJECT-GROUP
              OBJECTS     { rptrMonitorPortIsolates,
                            rptrMonitorPortSymbolErrors,
                            rptrMonitorPortUpper32Octets,
                            rptrMonitorPortHCReadableOctets,

                            rptrMonUpper32TotalOctets,
                            rptrMonHCTotalOctets }
              STATUS      current
              DESCRIPTION
                  "Monitor group for 100Mb/s ports and repeaters in a
                  system with one or more repeater-units in restart
                  version of the MIB module."
              ::= { snmpRptrModObjGrps 7 }

          snmpRptrGrpAddrTrackRS OBJECT-GROUP
              OBJECTS     { rptrAddrTrackGroupIndex,
                            rptrAddrTrackPortIndex,
                            rptrAddrTrackSourceAddrChanges,
                            rptrAddrTrackNewLastSrcAddress,
                            rptrAddrTrackCapacity }
              STATUS      current
              DESCRIPTION
                  "Address tracking group for restart version
                  of the MIB module."





          Expires August 1996                                  [Page 68]


          Internet Draft        802.3 Repeater MIB      14 February 1996


              ::= { snmpRptrModObjGrps 8 }

          snmpRptrGrpExtAddrTrack OBJECT-GROUP
              OBJECTS     { rptrExtAddrTrackMacIndex,
                            rptrExtAddrTrackSourceAddress,
                            rptrAddrTrackReset }
              STATUS      current
              DESCRIPTION
                  "Extended address tracking group for a system
                  with one or more repeater-units in restart
                  version of the MIB module."
              ::= { snmpRptrModObjGrps 9 }

          snmpRptrGrpTopNPort OBJECT-GROUP
              OBJECTS     { rptrTopNPortControlIndex,
                            rptrTopNPortRepeaterId,
                            rptrTopNPortRateBase,
                            rptrTopNPortTimeRemaining,
                            rptrTopNPortDuration,
                            rptrTopNPortRequestedSize,
                            rptrTopNPortGrantedSize,
                            rptrTopNPortStartTime,
                            rptrTopNPortOwner,
                            rptrTopNPortRowStatus,
                            rptrTopNPortIndex,
                            rptrTopNPortGroupIndex,
                            rptrTopNPortPortIndex,
                            rptrTopNPortRate }
              STATUS      current
              DESCRIPTION
                  "Top `N' group for repeater ports."
              ::= { snmpRptrModObjGrps 10 }



          -- Notification groups

          -- ?? later


          -- Compliances

          snmpRptrModComplRFC1368 MODULE-COMPLIANCE
              STATUS      obsolete
              DESCRIPTION





          Expires August 1996                                  [Page 69]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                  "Compliance for RFC 1368.

                  NOTE: this module compliance is OBSOLETE and
                        replaced by snmpRptrModComplRFC1516."

              MODULE -- this module
                  MANDATORY-GROUPS { snmpRptrGrpBasic }

                  GROUP snmpRptrGrpMonitor
                  DESCRIPTION
                      "Implementation of this optional group is
                      recommended for systems which have the
                      instrumentation to do performance monitoring."

                  GROUP snmpRptrGrpAddrTrack
                  DESCRIPTION
                      "Implementation of this group is
                      recommended for systems which have
                      the necessary instrumentation."

              ::= { snmpRptrModCompls 1 }

          snmpRptrModComplRFC1516 MODULE-COMPLIANCE
              STATUS      deprecated
              DESCRIPTION
                  "Compliance for RFC 1516 and for backwards
                  compatibility with single-repeater,
                  10Mb/s-only implementations."

              MODULE -- this module
                  MANDATORY-GROUPS { snmpRptrGrpBasic }

                  GROUP snmpRptrGrpMonitor
                  DESCRIPTION
                      "Implementation of this optional group is
                      recommended for systems which have the
                      instrumentation to do performance monitoring."

                  GROUP snmpRptrGrpAddrTrackNewSrcAddr
                  DESCRIPTION
                      "Implementation of this group is
                      recommended for systems which have
                      the necessary instrumentation."

              ::= { snmpRptrModCompls 2 }





          Expires August 1996                                  [Page 70]


          Internet Draft        802.3 Repeater MIB      14 February 1996


          snmpRptrModComplRS MODULE-COMPLIANCE
              STATUS      current
              DESCRIPTION
                  "Compliance for the `restart version' of the
                  MIB module for a system with one or more
                  repeater-units."

              MODULE -- this module
                  MANDATORY-GROUPS { snmpRptrGrpBasicRS }

                  GROUP snmpRptrGrpMonitorRS
                  DESCRIPTION
                      "Implementation of this optional group is
                      recommended for systems which have the
                      instrumentation to do performance monitoring."

                  GROUP snmpRptrGrpMonitor100RS
                  DESCRIPTION
                      "Implementation of this optional group
                      is recommended for systems which contain
                      100Mb/s repeaters and have the
                      instrumentation to do performance
                      monitoring."

                  GROUP snmpRptrGrpAddrTrackRS
                  DESCRIPTION
                      "Implementation of this group is
                      recommended for systems which have
                      the necessary instrumentation to
                      track MAC address of a single DTE
                      attached to a repeater port."

                  GROUP snmpRptrGrpExtAddrTrack
                  DESCRIPTION
                      "Implementation of this group is
                      appropriate for systems which have
                      the necessary instrumentation to track
                      MAC addresses of multiple DTEs attached
                      to a single repeater port."

                  GROUP snmpRptrGrpTopNPort
                  DESCRIPTION
                      "Implementation of this group is
                      recommended for systems which have
                      the necessary resources to support





          Expires August 1996                                  [Page 71]


          Internet Draft        802.3 Repeater MIB      14 February 1996


                      TopN statistics reporting."

              ::= { snmpRptrModCompls 3 }


          END












































          Expires August 1996                                  [Page 72]


          Internet Draft        802.3 Repeater MIB      14 February 1996


          4.  References

          [1]  IEEE 802.3/ISO 8802-3 Information processing systems -
               Local area networks - Part 3:  Carrier sense multiple
               access with collision detection (CSMA/CD) access method
               and physical layer specifications, 1993.

          [2]  IEEE 802.3u-1995, "MAC Parameters, Physical Layer, Medium
               Attachment Units and Repeater for 100 Mb/s Operation,
               Type 100BASE-T," Sections 21 through 29, Supplement to
               IEEE Std 802.3, October 26, 1995.

          [3]  IEEE 802.3u-1995, "10 & 100 Mb/s Management," Section 30,
               Supplement to IEEE Std 802.3, October 26, 1995.

          [4]  Romascanu, D., and K. de Graaf, "Definitions of Managed
               Objects for IEEE 802.3 Medium Attachment Units (MAUs)",
               February 1996.

          [5]  McCloghrie, K., and M. Rose, Editors, "Management
               Information Base for Network Management of TCP/IP-based
               internets: MIB-II", STD 17, RFC 1213, Hughes LAN Systems,
               Performance Systems International, March 1991.



























          Expires August 1996                                  [Page 73]