Ethernet Interfaces and Hub MIB Working Group                 Mike Ayers
INTERNET DRAFT                                        BMC Software, Inc.
                                                              John Flick
                                                 Hewlett-Packard Company
                                                             C. M. Heard
                                                              Consultant
                                                                 Kam Lam
                                                     Lucent Technologies
                                                          Kerry McDonald
                                                      CSU San Bernardino
                                                           K. C. Norseth
                                                      Enterasys Networks
                                                              Kaj Tesink
                                                  Telcordia Technologies
                                                       February 18, 2002


                     Definitions of Managed Objects
                for the Ethernet WAN Interface Sublayer
                   <draft-ietf-hubmib-wis-mib-02.txt>


Status of this Memo

   This document is an Internet-Draft and is in full conformance with
   all provisions of Section 10 of RFC2026.  Internet-Drafts are working
   documents of the Internet Engineering Task Force (IETF), its areas,
   and its working groups.  Note that other groups may also distribute
   working documents as Internet-Drafts.

   Internet-Drafts are draft documents valid for a maximum of six months
   and may be updated, replaced, or obsoleted by other documents at any
   time.  It is inappropriate to use Internet-Drafts as reference
   material or to cite them other than as "work in progress."

   The list of current Internet-Drafts can be accessed at
   http://www.ietf.org/ietf/1id-abstracts.txt

   The list of Internet-Draft Shadow Directories can be accessed at
   http://www.ietf.org/shadow.html

Copyright Notice

   Copyright (C) The Internet Society (2002).  All Rights Reserved.







Expires 08/18/2002        Ethernet WIS Objects                  [Page 1]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


1.  Abstract

   This document defines a portion of the Management Information Base
   (MIB) for use with network management protocols in TCP/IP based
   internets.  In particular, it defines objects for managing the
   Ethernet Wide Area Network (WAN) Interface Sublayer (WIS) [P802.3ae].

   The MIB module defined in this memo is implemented in conjunction
   with the Ethernet-like Interface MIB [ETHERIF], the 802.3 Medium
   Attachment Unit MIB [MAU-MIB], the Interfaces Group MIB [RFC2863],
   and the Inverted Stack Table MIB [RFC2864].  It also extends the
   SONET MIB [SONETng] and is implemented in conjunction with that MIB
   module.

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
   document are to be interpreted as described in [RFC2119].

2.  The SNMP Management Framework

   The SNMP Management Framework presently consists of five major
   components:

    o   An overall architecture, described in RFC 2571 [RFC2571].

    o   Mechanisms for describing and naming objects and events for the
        purpose of management.  The first version of this Structure of
        Management Information (SMI) is called SMIv1 and described in
        STD 16, RFC 1155 [RFC1155], STD 16, RFC 1212 [RFC1212] and RFC
        1215 [RFC1215].  The second version, called SMIv2, is described
        in STD 58, RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and
        STD 58, RFC 2580 [RFC2580].

    o   Message protocols for transferring management information.  The
        first version of the SNMP message protocol is called SNMPv1 and
        described in STD 15, RFC 1157 [RFC1157].  A second version of
        the SNMP message protocol, which is not an Internet standards
        track protocol, is called SNMPv2c and described in RFC 1901
        [RFC1901] and RFC 1906 [RFC1906].  The third version of the
        message protocol is called SNMPv3 and described in RFC 1906
        [RFC1906], RFC 2572 [RFC2572] and RFC 2574 [RFC2574].

    o   Protocol operations for accessing management information.  The
        first set of protocol operations and associated PDU formats is
        described in STD 15, RFC 1157 [RFC1157].  A second set of
        protocol operations and associated PDU formats is described in
        RFC 1905 [RFC1905].




Expires 08/18/2002        Ethernet WIS Objects                  [Page 2]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


    o   A set of fundamental applications described in RFC 2573
        [RFC2573] and the view-based access control mechanism described
        in RFC 2575 [RFC2575].

   A more detailed introduction to the current SNMP Management Framework
   can be found in RFC 2570 [RFC2570].

   Managed objects are accessed via a virtual information store, termed
   the Management Information Base or MIB.  Objects in the MIB are
   defined using the mechanisms defined in the SMI.

   This memo specifies a MIB module that is compliant to the SMIv2.  A
   MIB conforming to the SMIv1 can be produced through the appropriate
   translations.  The resulting translated MIB must be semantically
   equivalent, except where objects or events are omitted because no
   translation is possible (use of Counter64).  Some machine readable
   information in SMIv2 will be converted into textual descriptions in
   SMIv1 during the translation process.  However, this loss of machine
   readable information is not considered to change the semantics of the
   MIB.

3.  Overview

   The objects defined in this memo are used in conjunction with objects
   defined in the Interfaces Group MIB [RFC2863], the SONET MIB
   [SONETng], and the MAU MIB [MAU-MIB] to manage the WAN Interface
   Sublayer (WIS) defined in [P802.3ae].  The WIS contains functions to
   perform OC-192c/VC-4-64c framing and scrambling.  It resides between
   the PCS and PMA sublayers within a 10GBASE-W 10 Gb/s WAN-compatible
   PHY and may be used in conjunction with any of the PCS, PMA, and PMD
   sublayers that are defined in [P802.3ae] for 10GBASE-W PHYs.  Three
   types of 10GBASE-W PHYs are defined, distinguished by the type of
   optics employed:  10GBASE-SW, 10GBASE-LW, and 10GBASE-EW.  The
   objects defined in this memo may be used to manage an Ethernet
   interface employing any type of 10GBASE-W PHY.  They do not apply to
   any other kind of interface.  In particular, they do not apply to
   so-called Ethernet Line Terminating Equipment (ELTE) residing within
   a SONET network element that uses the 10GBASE-W PMA/PMD sublayers but
   otherwise acts as SONET Line Terminating Equipment (LTE).

   The objects presented here -- along with those incorporated by
   reference from the Interfaces Group MIB, the SONET MIB, and the MAU
   MIB -- are intended to provide exact representations of the mandatory
   attributes in the oWIS managed object class (i.e., the members of the
   pWISBasic package) defined in Clause 30 and Annex 30A of [P802.3ae].
   They are also intended to provide approximate representations of the
   optional attributes (i.e., the members of the pWISOptional package).
   Some objects with no analogues in oWIS are defined to support WIS
   testing features required by Clause 50 of [P802.3ae].


Expires 08/18/2002        Ethernet WIS Objects                  [Page 3]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


3.1.  Relationship to the SONET MIB

   Since the Ethernet WAN Interface Sublayer was designed to be SONET-
   compatible, information similar to that provided by most of the
   members of the oWIS managed object class is available from objects
   defined in the SONET MIB [SONETng].  Thus, the MIB module defined in
   this memo is a sparse augmentation of the SONET MIB -- in other
   words, every table defined here is an extension of some table in the
   SONET MIB -- and its compliance statement REQUIRES that an agent
   implementing the objects defined in this memo also implement the
   relevant SONET MIB objects.  That includes all objects required by
   sonetCompliance2 as well as some that it leaves optional.

   It should be noted that some of the objects incorporated by reference
   from the SONET MIB -- specifically, the threshold objects and
   interval counter objects -- provide only approximate representations
   of the corresponding oWIS attributes, as detailed in Section 3.6.  An
   alternative approach would have been to define new objects to exactly
   match the oWIS definitions.  That approach was rejected because the
   SONET MIB objects are already used in deployed systems to manage the
   SONET sublayers of ATM over SONET and PPP over SONET interfaces, and
   it was deemed undesirable to use a different scheme to manage the
   SONET sublayers of 10 Gb/s WAN-compatible Ethernet interfaces.  Note
   that the approach adopted by this memo requires no hardware support
   beyond that mandated by [P802.3ae] subclause 50.3.10.

3.2.  Relationship to the Ethernet-like Interfaces MIB

   An interface which includes the Ethernet WIS is, by definition, an
   Ethernet-like interface, and an agent implementing the objects
   defined in this memo MUST implement the objects required by the
   dot3Compliance2 compliance statement in the EtherLike-MIB.

3.3.  Relationship to the 802.3 MAU MIB

   Support for the mauModIfCompl2 compliance statement of the MAU-MIB
   [MAU-MIB] is REQUIRED for all Ethernet-like interfaces.  The MAU-MIB
   is needed in order to allow applications to control and/or determine
   the media type in use.  That is important for devices than can
   support both the 10GBASE-R 10 Gb/s LAN format (which does not include
   the WIS) and the 10GBASE-W 10 Gb/s WAN format (which does include the
   WIS).  The MAU-MIB also provides the means to put a device in standby
   mode or to reset it;  the latter may be used to re-initialize the
   WIS.

3.4.  Use of the ifTable

   This section specifies how the ifTable, as defined in [RFC2863], is
   used for the Ethernet WIS application.


Expires 08/18/2002        Ethernet WIS Objects                  [Page 4]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


3.4.1.  Layering Model

   Ethernet interfaces that employ the WIS are layered as defined in
   [P802.3ae].  The corresponding use of the ifTable [RFC2863] is shown
   in the figure below.

           _____________________________   _
          |    LLC Layer                |  |
          +-----------------------------+  |
          |    MAC Layer                |  |
          +-----------------------------+  > 1 ifEntry
          |    Reconciliation Sublayer  |  |   ifType: ethernetCsmacd(6)
          +-----------------------------+  |
          |    Physical Coding Sublayer |  |
          +-----------------------------+  +
          |    Path Layer               |  > 1 ifEntry
          +-----------------------------+  +   ifType: sonetPath(50)
          |    Line Layer               |  |
          +-----------------------------+  |
          |    Section Layer            |  > 1 ifEntry
          +-----------------------------+  |   ifType: sonet(39)
          |    Physical Medium Layer    |  |
           -----------------------------   -

       Figure 1 - Use of ifTable for an Ethernet WIS port

   The exact configuration and multiplexing of the layers is maintained
   in the ifStackTable [RFC2863] and in the ifInvStackTable [RFC2864].

3.4.2.  Use of ifTable for LLC Layer/MAC Layer/Reconciliation
Sublayer/Physical Coding Sublayer

   The ifTable MUST be used as specified in [ETHERIF] and [MAU-MIB] for
   the LLC Layer/MAC Layer/Reconciliation Sublayer/Physical Coding
   Sublayer.

3.4.3.  Use of ifTable for SONET/SDH Path Layer

   The ifTable MUST be used as specified in [SONETng] for the SONET/SDH
   Path Layer.  The value of ifHighSpeed is set to 9585.  ifSpeed
   reports a value of 4294967295.

3.4.4.  Use of ifTable for SONET/SDH Medium/Section/Line Layer

   The ifTable MUST be used as specified in [SONETng] for the SONET/SDH
   Medium/Section/Line Layer.  The value of ifHighSpeed is set to 9953.
   ifSpeed reports a value of 4294967295.




Expires 08/18/2002        Ethernet WIS Objects                  [Page 5]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


3.5.  SONET/SDH Terminology

   The SONET/SDH terminology used in [P802.3ae] is mostly the same as in
   [SONETng], but there are a few differences.  In those cases the
   definitions in [P802.3ae] take precedence.  The specific differences
   are as follows.

   Unequipped
       This defect is not defined by [P802.3ae].  An implementation that
       supports it SHOULD report it by setting the sonetPathUnequipped
       bit in the appropriate instance of sonetPathCurrentStatus.

   Signal Label Mismatch
       This defect is called Payload Label Mismatch (PLM) in [P802.3ae].
       It is reported by setting both the sonetPathSignalLabelMismatch
       bit in the appropriate instance of sonetPathCurrentStatus
       (defined in [SONETng]) and the etherWisPathPLM bit in the
       corresponding instance of etherWisPathCurrentStatus (defined
       below).

   Loss of Codegroup Delineation
       [P802.3ae] defines Loss of Codegroup Delineation (LCD) as
       occurring when the Physical Coding Sublayer is unable to locate
       64B/66B code group boundaries.  There is no analogous defect
       defined in [SONETng].  It is reported by setting the
       etherWisPathLCD bit in the appropriate instance of the object
       etherWisPathCurrentStatus defined below.

   STS-Path Remote Defect Indication
       [P802.3ae] mandates the use of ERDI-P (Enhanced Remote Defect
       Indication - Path) defined in [T1.231] to signal remote server
       defects (triggered by path AIS or path LOP) and remote payload
       defects (triggered by Payload Label Mismatch or Loss of Codegroup
       Delineation).  [SONETng] defines the one-bit RDI-P (Remote Defect
       Indication - Path), which signals remote server detects (i.e.,
       path AIS and path LOP) only.  An implementation of the MIB module
       defined in this memo MUST set the sonetPathSTSRDI bit in the
       appropriate instance of sonetPathCurrentStatus when it receives
       an ERDI-P server defect indication from the remote end.  Both
       ERDI-P payload defects and ERDI-P server defects are reported in
       the object etherWisFarEndPathCurrentStatus defined below.

   Path Coding Violations
       In [P802.3ae] the path layer CV count is based on block errors
       and not BIP-8 errors, i.e., it is incremented only once for each
       B3 byte that indicates incorrect parity, regardless of the number
       of bits in error.  Note that Section 8.4.5.1 of [T1.231] allows
       either path BIP-8 errors or path block errors to be used for the
       path layer error count.


Expires 08/18/2002        Ethernet WIS Objects                  [Page 6]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


3.6.  Mapping of IEEE 802.3 Managed Objects

   This section contains the mapping between oWIS managed objects
   defined in [P802.3ae] and managed objects defined in this document
   and in associated MIB modules, i.e., the IF-MIB [RFC2863], the
   SONET-MIB [SONETng], and the MAU-MIB [MAU-MIB].

   IEEE 802.3 Managed Object    Corresponding SNMP Object

   oWIS - pWISBasic package
    aWISID                      IF-MIB - ifIndex
    aSectionStatus              SONET-MIB - sonetSectionCurrentStatus
    aLineStatus                 SONET-MIB - sonetLineCurrentStatus
    aPathStatus                 etherWisPathCurrentStatus
    aFarEndPathStatus           etherWisFarEndPathCurrentStatus

   oWIS - pWISOptional package
    aSectionSESThreshold        SONET-MIB - sonetSESthresholdSet
    aSectionSESs                SONET-MIB - sonetSectionCurrentSESs +
                                            sonetSectionIntervalSESs
    aSectionESs                 SONET-MIB - sonetSectionCurrentESs +
                                            sonetSectionIntervalESs
    aSectionSEFSs               SONET-MIB - sonetSectionCurrentSEFSs +
                                            sonetSectionIntervalSEFSs
    aSectionCVs                 SONET-MIB - sonetSectionCurrentCVs +
                                            sonetSectionIntervalCVs
    aJ0ValueTX                  etherWisSectionCurrentJ0Transmitted
    aJ0ValueRX                  etherWisSectionCurrentJ0Received
    aLineSESThreshold           SONET-MIB - sonetSESthresholdSet
    aLineSESs                   SONET-MIB - sonetLineCurrentSESs +
                                            sonetLineIntervalSESs
    aLineESs                    SONET-MIB - sonetLineCurrentESs +
                                            sonetLineIntervalESs
    aLineCVs                    SONET-MIB - sonetLineCurrentCVs +
                                            sonetLineIntervalCVs
    aFarEndLineSESs             SONET-MIB - sonetFarEndLineCurrentSESs +
                                            sonetFarEndLineIntervalSESs
    aFarEndLineESs              SONET-MIB - sonetFarEndLineCurrentESs +
                                            sonetFarEndLineIntervalESs
    aFarEndLineCVs              SONET-MIB - sonetFarEndLineCurrentCVs +
                                            sonetFarEndLineIntervalCVs
    aPathSESThreshold           SONET-MIB - sonetSESthresholdSet
    aPathSESs                   SONET-MIB - sonetPathCurrentSESs +
                                            sonetPathIntervalSESs
    aPathESs                    SONET-MIB - sonetPathCurrentESs +
                                            sonetPathIntervalESs
    aPathCVs                    SONET-MIB - sonetPathCurrentCVs +
                                            sonetPathIntervalCVs
    aJ1ValueTX                  etherWisPathCurrentJ1Transmitted


Expires 08/18/2002        Ethernet WIS Objects                  [Page 7]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


    aJ1ValueRX                  etherWisPathCurrentJ1Received
    aFarEndPathSESs             SONET-MIB - sonetFarEndPathCurrentSESs +
                                            sonetFarEndPathIntervalSESs
    aFarEndPathESs              SONET-MIB - sonetFarEndPathCurrentESs +
                                            sonetFarEndPathIntervalESs
    aFarEndPathCVs              SONET-MIB - sonetFarEndPathCurrentCVs +
                                            sonetFarEndPathIntervalCVs

   It should be noted that the threshold and counter objects imported
   from the SONET-MIB are not completely equivalent to the corresponding
   IEEE 802.3 objects.  The specific differences are as follows:

   IEEE 802.3 Managed Object    How Corresponding SNMP Object Differs

   oWIS - pWISOptional package
    aSectionSESThreshold        This object is defined in [P802.3ae]
                                as an integer with one instance per
                                interface.  sonetSESthresholdSet
                                is an enumerated value that has one
                                instance per network element;  it
                                controls the thresholds for all layers
                                simultaneously and allows only certain
                                discrete values to be selected.
    aSectionSESs                This object is defined in [P802.3ae] as
                                a generalized nonresetable counter.
                                The objects sonetSectionCurrentSESs and
                                sonetSectionIntervalSESs are 15-minute
                                interval counters.
    aSectionESs                 This object is defined as a generalized
                                nonresetable counter in [P802.3ae].
                                The objects sonetSectionCurrentESs and
                                sonetSectionIntervalESs are 15-minute
                                interval counters.
    aSectionSEFSs               This object is defined as a generalized
                                nonresetable counter in [P802.3ae].
                                The objects sonetSectionCurrentSEFSs and
                                sonetSectionIntervalSEFSs are 15-minute
                                interval counters.
    aSectionCVs                 This object is defined as a generalized
                                nonresetable counter in [P802.3ae], and
                                it is not subject to inhibiting.  The
                                objects sonetSectionCurrentCVs and
                                sonetSectionIntervalCVs are 15-minute
                                interval counters, and they are
                                inhibited (not incremented) during
                                one-second intervals that qualify as
                                severely errored seconds.
    aLineSESThreshold           This object is defined in [P802.3ae]
                                as an integer with one instance per


Expires 08/18/2002        Ethernet WIS Objects                  [Page 8]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


                                interface.  sonetSESthresholdSet
                                is an enumerated value that has one
                                instance per network element;  it
                                controls the thresholds for all layers
                                simultaneously and allows only certain
                                discrete values to be selected.
    aLineSESs                   This object is defined as a generalized
                                nonresetable counter in [P802.3ae], and
                                it is not subject to inhibiting.  The
                                objects sonetLineCurrentSESs and
                                sonetLineIntervalSESs are 15-minute
                                interval counters, and they are
                                inhibited (not incremented) during
                                one-second intervals that qualify as
                                unavailable seconds.
    aLineESs                    This object is defined as a generalized
                                nonresetable counter in [P802.3ae], and
                                it is not subject to inhibiting.  The
                                objects sonetLineCurrentESs and
                                sonetLineIntervalESs are 15-minute
                                interval counters, and they are
                                inhibited (not incremented) during
                                one-second intervals that qualify as
                                unavailable seconds.
    aLineCVs                    This object is defined as a generalized
                                nonresetable counter in [P802.3ae], and
                                it is not subject to inhibiting.  The
                                objects sonetLineCurrentCVs and
                                sonetLineIntervalCVs are 15-minute
                                interval counters, and they are
                                inhibited (not incremented) during
                                one-second intervals that qualify
                                either as severely errored seconds
                                or as unavailable seconds.
    aFarEndLineSESs             This object is defined as a generalized
                                nonresetable counter in [P802.3ae], and
                                it is not subject to inhibiting.  The
                                objects sonetFarEndLineCurrentSESs and
                                sonetFarEndLineIntervalSESs are
                                15-minute interval counters, and they
                                are inhibited (not incremented) during
                                one-second intervals that qualify as
                                unavailable seconds.
    aFarEndLineESs              This object is defined as a generalized
                                nonresetable counter in [P802.3ae], and
                                it is not subject to inhibiting.  The
                                objects sonetFarEndLineCurrentESs and
                                sonetFarEndLineIntervalESs are 15-minute
                                interval counters, and they are


Expires 08/18/2002        Ethernet WIS Objects                  [Page 9]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


                                inhibited (not incremented) during
                                one-second intervals that qualify as
                                unavailable seconds.
    aFarEndLineCVs              This object is defined as a generalized
                                nonresetable counter in [P802.3ae], and
                                it is not subject to inhibiting.  The
                                objects sonetFarEndLineCurrentCVs and
                                sonetFarEndLineIntervalCVs are 15-minute
                                interval counters, and they are
                                inhibited (not incremented) during
                                one-second intervals that qualify
                                either as severely errored seconds
                                or as unavailable seconds.
    aPathSESThreshold           This object is defined in [P802.3ae]
                                as an integer with one instance per
                                interface.  sonetSESthresholdSet
                                is an enumerated value that has one
                                instance per network element;  it
                                controls the thresholds for all layers
                                simultaneously and allows only certain
                                discrete values to be selected.
    aPathSESs                   This object is defined as a generalized
                                nonresetable counter in [P802.3ae], and
                                it is not subject to inhibiting.  The
                                objects sonetPathCurrentSESs and
                                sonetPathIntervalSESs are 15-minute
                                interval counters, and they are
                                inhibited (not incremented) during
                                one-second intervals that qualify as
                                unavailable seconds.  In addition,
                                [P802.3ae] includes PLM-P and LCD-P
                                defects in the criteria for declaring
                                path layer severely errored seconds,
                                while [SONETng] does not.
    aPathESs                    This object is defined as a generalized
                                nonresetable counter in [P802.3ae], and
                                it is not subject to inhibiting.  The
                                objects sonetPathCurrentESs and
                                sonetPathIntervalESs are 15-minute
                                interval counters, and they are
                                inhibited (not incremented) during
                                one-second intervals that qualify as
                                unavailable seconds.  In addition,
                                [P802.3ae] includes PLM-P and LCD-P
                                defects in the criteria for declaring
                                path layer errored seconds, while
                                [SONETng] does not.
    aPathCVs                    This object is defined as a generalized
                                nonresetable counter in [P802.3ae], and


Expires 08/18/2002        Ethernet WIS Objects                 [Page 10]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


                                it is not subject to inhibiting.  The
                                objects sonetPathCurrentCVs and
                                sonetPathIntervalCVs are 15-minute
                                interval counters, and they are
                                inhibited (not incremented) during
                                one-second intervals that qualify
                                either as severely errored seconds
                                or as unavailable seconds.
    aFarEndPathSESs             This object is defined as a generalized
                                nonresetable counter in [P802.3ae], and
                                it is not subject to inhibiting.  The
                                objects sonetFarEndPathCurrentSESs and
                                sonetFarEndPathIntervalSESs are
                                15-minute interval counters, and they
                                are inhibited (not incremented) during
                                one-second intervals that qualify as
                                unavailable seconds.  In addition,
                                [P802.3ae] includes far-end PLM-P and
                                LCD-P defects in the criteria for
                                declaring far-end path layer severely
                                errored seconds, while [SONETng] does
                                not.
    aFarEndPathESs              This object is defined as a generalized
                                nonresetable counter in [P802.3ae], and
                                it is not subject to inhibiting.  The
                                objects sonetFarEndPathCurrentESs and
                                sonetFarEndPathIntervalESs are 15-minute
                                interval counters, and they are
                                inhibited (not incremented) during
                                one-second intervals that qualify as
                                unavailable seconds.  In addition,
                                [P802.3ae] includes far-end PLM-P and
                                LCD-P defects in the criteria for
                                declaring far-end path layer errored
                                seconds, while [SONETng] does not.
    aFarEndPathCVs              This object is defined as a generalized
                                nonresetable counter in [P802.3ae], and
                                it is not subject to inhibiting.  The
                                objects sonetFarEndPathCurrentCVs and
                                sonetFarEndPathIntervalCVs are 15-minute
                                interval counters, and they are
                                inhibited (not incremented) during
                                one-second intervals that qualify
                                either as severely errored seconds
                                or as unavailable seconds.

   Please note that despite the differences in semantics between the
   threshold objects and counter objects imported from the SONET-MIB and
   the corresponding IEEE 802.3 objects, the hardware support mandated


Expires 08/18/2002        Ethernet WIS Objects                 [Page 11]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


   by [P802.3ae] subclause 50.3.10 suffices for both.  See Appendix A
   for details.

3.7.  Mapping of SNMP Objects to WIS Station Management Registers

   Some of the objects defined in this memo or incorporated by reference
   from the SONET-MIB [SONETng] or the MAU-MIB [MAU-MIB] require WIS-
   specific hardware support.  [P802.3ae] subclause 50.3.10 specifies
   WIS management interface requirements, including a required subset of
   the WIS MDIO (Management Data Input/Output) registers defined in
   [P802.3ae] subclause 45.2.2.  The table below provides a cross-
   reference between those managed objects and the WIS MDIO registers
   from the subset in [P802.3ae] subclause 50.3.10 required to support
   them.  Note that the MDIO interface is optional;  however, if it is
   not implemented, then the capabilities of the required register
   subset must be provided by other means.

   SNMP Object                                     WIS MDIO Register(s)

   ETHER-WIS - etherWisDeviceTxTestPatternMode     10G WIS Control 2
   ETHER-WIS - etherWisDeviceRxTestPatternMode     10G WIS Control 2
   ETHER-WIS - etherWisDeviceRxTestPatternErrors   10G WIS Test Pattern
                                                           Error Counter

   SONET-MIB - sonetMediumType                     none required
   SONET-MIB - sonetMediumTimeElapsed              none required
   SONET-MIB - sonetMediumValidIntervals           none required
   SONET-MIB - sonetMediumLineCoding               none required
   SONET-MIB - sonetMediumLineType                 none required
   SONET-MIB - sonetMediumCircuitIdentifier        none required
   SONET-MIB - sonetMediumInvalidIntervals         none required
   SONET-MIB - sonetMediumLoopbackConfig           none required
   SONET-MIB - sonetSESthresholdSet                none required

   ETHER-WIS - etherWisSectionCurrentJ0Transmitted 10G WIS J0 Tx
   ETHER-WIS - etherWisSectionCurrentJ0Received    10G WIS J0 Rx

   SONET-MIB - sonetSectionCurrentStatus           10G WIS Status 3
   SONET-MIB - sonetSectionCurrentESs              \
   SONET-MIB - sonetSectionCurrentSESs              \
   SONET-MIB - sonetSectionCurrentSEFSs              | 10G WIS Status 3
   SONET-MIB - sonetSectionCurrentCVs                |        +
   SONET-MIB - sonetSectionIntervalESs               | 10G WIS Section
   SONET-MIB - sonetSectionIntervalSESs              | BIP Error Count
   SONET-MIB - sonetSectionIntervalSEFSs            /
   SONET-MIB - sonetSectionIntervalCVs             /
   SONET-MIB - sonetSectionIntervalValidData       none required




Expires 08/18/2002        Ethernet WIS Objects                 [Page 12]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


   SONET-MIB - sonetLineCurrentStatus              10G WIS Status 3
   SONET-MIB - sonetLineCurrentESs                 \
   SONET-MIB - sonetLineCurrentSESs                 \
   SONET-MIB - sonetLineCurrentCVs                   | 10G WIS Status 3
   SONET-MIB - sonetLineCurrentUASs                  |        +
   SONET-MIB - sonetLineIntervalESs                  | 10G WIS Line
   SONET-MIB - sonetLineIntervalSESs                 | BIP Errors
   SONET-MIB - sonetLineIntervalCVs                 /
   SONET-MIB - sonetLineIntervalUASs               /
   SONET-MIB - sonetLineIntervalValidData          none required

   SONET-MIB - sonetFarEndLineCurrentESs           \
   SONET-MIB - sonetFarEndLineCurrentSESs           \
   SONET-MIB - sonetFarEndLineCurrentCVs             | 10G WIS Status 3
   SONET-MIB - sonetFarEndLineCurrentUASs            |        +
   SONET-MIB - sonetFarEndLineIntervalESs            | 10G WIS Far End
   SONET-MIB - sonetFarEndLineIntervalSESs           | Line BIP Errors
   SONET-MIB - sonetFarEndLineIntervalCVs           /
   SONET-MIB - sonetFarEndLineIntervalUASs         /
   SONET-MIB - sonetFarEndLineIntervalValidData    10G WIS Status 3

   ETHER-WIS - etherWisPathCurrentStatus           10G WIS Status 3
   ETHER-WIS - etherWisPathCurrentJ1Transmitted    10G WIS J1 Tx
   ETHER-WIS - etherWisPathCurrentJ1Received       10G WIS J1 Rx

   SONET-MIB - sonetPathCurrentWidth               none required
   SONET-MIB - sonetPathCurrentStatus              10G WIS Status 3
   SONET-MIB - sonetPathCurrentESs                 \
   SONET-MIB - sonetPathCurrentSESs                 \
   SONET-MIB - sonetPathCurrentCVs                   | 10G WIS Status 3
   SONET-MIB - sonetPathCurrentUASs                  |        +
   SONET-MIB - sonetPathIntervalESs                  | 10G WIS
   SONET-MIB - sonetPathIntervalSESs                 | Path Block
   SONET-MIB - sonetPathIntervalCVs                 /  Error Count
   SONET-MIB - sonetPathIntervalUASs               /
   SONET-MIB - sonetPathIntervalValidData          none required

   ETHER-WIS - etherWisFarEndPathCurrentStatus     10G WIS Status 3

   SONET-MIB - sonetFarEndPathCurrentESs           \
   SONET-MIB - sonetFarEndPathCurrentSESs           \
   SONET-MIB - sonetFarEndPathCurrentCVs             | 10G WIS Status 3
   SONET-MIB - sonetFarEndPathCurrentUASs            |        +
   SONET-MIB - sonetFarEndPathIntervalESs            | 10G WIS Far End
   SONET-MIB - sonetFarEndPathIntervalSESs           | Path Block
   SONET-MIB - sonetFarEndPathIntervalCVs           /  Error Count
   SONET-MIB - sonetFarEndPathIntervalUASs         /
   SONET-MIB - sonetFarEndPathIntervalValidData    10G WIS Status 3



Expires 08/18/2002        Ethernet WIS Objects                 [Page 13]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


   MAU-MIB - ifMauIfIndex                          none required
   MAU-MIB - ifMauIndex                            none required
   MAU-MIB - ifMauType                             10G WIS Control 2
   MAU-MIB - ifMauStatus                           WIS Control 1
   MAU-MIB - ifMauMediaAvailable                   \ WIS Status 1 +
   MAU-MIB - ifMauMediaAvailableStateExits         / 10G WIS Status 3
   MAU-MIB - ifMauJabberState                      none required
   MAU-MIB - ifMauJabberingStateEnters             none required
   MAU-MIB - ifMauFalseCarriers                    none required
   MAU-MIB - ifMauDefaultType                      10G WIS Control 2
   MAU-MIB - ifMauAutoNegSupported                 none required
   MAU-MIB - ifMauTypeListBits                     10G WIS Status 2

3.8.  Structure of the MIB Module

   Four tables are defined in this MIB module.

3.8.1.  etherWisDeviceTable

   The purpose of this table is to define managed objects to control the
   WIS test pattern mode.  These objects are required to support
   mandatory and optional WIS test features specified in [P802.3ae]
   subclause 50.3.8.

   The etherWisDeviceTable is a sparse augmentation of the
   sonetMediumTable of the SONET MIB -- in other words, for each entry
   in the etherWisDeviceTable there MUST be an entry in the
   sonetMediumTable and the same ifIndex value SHALL be used for both
   entries.

3.8.2.  etherWisSectionCurrentTable

   The purpose of this table is to define managed objects for the
   transmitted and received section trace messages (J0 byte).

   The etherWisSectionCurrentTable is a sparse augmentation of the
   sonetSectionCurrentTable of the SONET MIB -- in other words, for each
   entry in the etherWisSectionCurrentTable there MUST be an entry in
   the sonetSectionCurrentTable and the same ifIndex value SHALL be used
   for both entries.

3.8.3.  etherWisPathCurrentTable

   The purpose of this table is to define managed objects for the
   current WIS path layer status and for the transmitted and received
   path trace messages (J1 byte).  The path layer status object is
   provided because the WIS supports some near-end path status
   conditions that are not reported in sonetPathCurrentStatus.



Expires 08/18/2002        Ethernet WIS Objects                 [Page 14]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


   The etherWisPathCurrentTable is a sparse augmentation of the
   sonetPathCurrentTable of the SONET MIB -- in other words, for each
   entry in the etherWisPathCurrentTable there MUST be an entry in the
   sonetPathCurrentTable and the same ifIndex value SHALL be used for
   both entries.

3.8.4.  etherWisFarEndPathCurrentTable

   The purpose of this table is to define a managed object for the
   current status of the far end of the path.  This object is provided
   because the WIS supports some far-end path status conditions that are
   not reported in sonetPathCurrentStatus.

   The etherWisFarEndPathCurrentTable is a sparse augmentation of the
   sonetFarEndPathCurrentTable of the SONET MIB -- in other words, for
   each entry in the etherWisFarEndPathCurrentTable there MUST be an
   entry in the sonetFarEndPathCurrentTable and the same ifIndex value
   SHALL be used for both entries.

































Expires 08/18/2002        Ethernet WIS Objects                 [Page 15]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


4.  Object Definitions

   ETHER-WIS DEFINITIONS ::= BEGIN

   IMPORTS
       MODULE-IDENTITY, OBJECT-TYPE,
       transmission
           FROM SNMPv2-SMI
       ifIndex
           FROM IF-MIB
       MODULE-COMPLIANCE, OBJECT-GROUP
           FROM SNMPv2-CONF
       sonetMediumStuff2, sonetSectionStuff2,
       sonetLineStuff2, sonetFarEndLineStuff2,
       sonetPathStuff2, sonetFarEndPathStuff2,
       sonetMediumType, sonetMediumLineCoding,
       sonetMediumLineType, sonetMediumCircuitIdentifier,
       sonetMediumLoopbackConfig, sonetSESthresholdSet,
       sonetPathCurrentWidth
           FROM SONET-MIB;

   etherWisMIB MODULE-IDENTITY
       LAST-UPDATED "200202180140Z"  -- February 18, 2002
           ORGANIZATION "IETF Ethernet Interfaces and Hub MIB
                        Working Group"
           CONTACT-INFO
              "WG charter:
                 http://www.ietf.org/html.charters/hubmib-charter.html

                Chair: Dan Romascanu
               Postal: Avaya Inc.
                       Atidim Technology Park, Bldg. 3
                       Tel Aviv 61131
                       Israel
                  Tel: +972 3 645 8414
               E-mail: dromasca@avaya.com

               Editor: C. M. Heard
               Postal: 600 Rainbow Dr. #141
                       Mountain View, CA 94041-2542
                       USA
                  Tel: +1 650-964-8391
               E-mail: heard@pobox.com"

       DESCRIPTION
         "The objects in this MIB module are used in conjunction
         with objects in the SONET-MIB and the MAU-MIB to manage
         the Ethernet WAN Interface Sublayer (WIS).



Expires 08/18/2002        Ethernet WIS Objects                 [Page 16]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


         The following reference is used throughout this MIB module:

         [IEEE 802.3 Std] refers to:
            IEEE Std 802.3, 2000 Edition: 'IEEE Standard for
            Information technology - Telecommunications and
            information exchange between systems - Local and
            metropolitan area networks - Specific requirements -
            Part 3: Carrier sense multiple access with collision
            detection (CSMA/CD) access method and physical layer
            specifications', as amended by IEEE Draft P802.3ae/D4.01:
            'Supplement to Carrier Sense Multiple Access with
            Collision Detection (CSMA/CD) Access Method & Physical
            Layer Specifications - Media Access Control (MAC)
            Parameters, Physical Layer, and Management Parameters
            for 10 Gb/s Operation', February 4, 2002.

         Of particular interest are Clause 50, 'WAN Interface
         Sublayer (WIS), type 10GBASE-W', Clause 30, '10Mb/s,
         100Mb/s, 1000Mb/s, and 10Gb/s MAC Control, and Link
         Aggregation Management', and Clause 45, 'Management
         Data Input/Output (MDIO) Interface'."

       REVISION    "200202180140Z"  -- February 18, 2002
       DESCRIPTION "Initial version, published as RFC yyyy."
-- RFC Ed.: replace yyyy with actual RFC number & remove this notice

       ::= { transmission XXX }
-- RFC Ed.: replace XXX with IANA-assigned number & remove this notice


   -- The main sections of the module

   etherWisObjects     OBJECT IDENTIFIER ::= { etherWisMIB 1 }

   etherWisObjectsPath OBJECT IDENTIFIER ::= { etherWisMIB 2 }

   etherWisConformance OBJECT IDENTIFIER ::= { etherWisMIB 3 }


   -- groups in the Ethernet WIS MIB module

   etherWisDevice      OBJECT IDENTIFIER ::= { etherWisObjects 1 }

   etherWisSection     OBJECT IDENTIFIER ::= { etherWisObjects 2 }

   etherWisPath        OBJECT IDENTIFIER ::= { etherWisObjectsPath 1 }

   etherWisFarEndPath  OBJECT IDENTIFIER ::= { etherWisObjectsPath 2 }



Expires 08/18/2002        Ethernet WIS Objects                 [Page 17]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


   -- The Device group

   -- These objects provide WIS extensions to
   -- the SONET-MIB Medium Group.

   etherWisDeviceTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF EtherWisDeviceEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "The table for Ethernet WIS devices"
        ::= { etherWisDevice 1 }

   etherWisDeviceEntry OBJECT-TYPE
       SYNTAX  EtherWisDeviceEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "An entry in the Ethernet WIS device table.  For each
          instance of this object there MUST be a corresponding
          instance of sonetMediumEntry."
       INDEX  { ifIndex }
        ::= { etherWisDeviceTable 1 }

   EtherWisDeviceEntry ::=
       SEQUENCE {
           etherWisDeviceTxTestPatternMode     INTEGER,
           etherWisDeviceRxTestPatternMode     INTEGER,
           etherWisDeviceRxTestPatternErrors   Gauge32
           }

   etherWisDeviceTxTestPatternMode OBJECT-TYPE
       SYNTAX  INTEGER {
                   none(0),
                   squareWave(1),
                   prbs31(2),
                   mixedFrequency(3)
               }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
          "This variable controls the transmit test pattern mode.
          The value none(0) puts the the WIS transmit path into
          the normal operating mode.  The value squareWave(1) puts
          the WIS transmit path into the square wave test pattern
          mode described in [IEEE 802.3 Std.] subclause 50.3.8.1.
          The value prbs31(2) puts the WIS transmit path into the
          PRBS31 test pattern mode described in [IEEE 802.3 Std.]
          subclause 50.3.8.2.  The value mixedFrequency(3) puts the


Expires 08/18/2002        Ethernet WIS Objects                 [Page 18]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


          WIS transmit path into the mixed frequency test pattern
          mode described in [IEEE 802.3 Std.] subclause 50.3.8.3.
          Any attempt to set this object to a value other than
          none(0) when the corresponding instance of ifAdminState
          has the value up(1) MUST be rejected with the error
          inconsistentValue, and any attempt to set the corresponding
          instance of ifAdminStatus to the value up(1) when an
          instance of this object has a value other than none(0)
          MUST be rejected with the error inconsistentValue."
       REFERENCE
          "[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
          checker, 45.2.2.6, 10G WIS Control 2 register (2.7), and
          45.2.2.7.2, PRBS31 pattern testing ability (2.8.1)."
        ::= { etherWisDeviceEntry 1 }

   etherWisDeviceRxTestPatternMode OBJECT-TYPE
       SYNTAX  INTEGER {
                   none(0),
                   prbs31(2),
                   mixedFrequency(3)
               }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
          "This variable controls the receive test pattern mode.
          The value none(0) puts the the WIS receive path into the
          normal operating mode.  The value prbs31(2) puts the WIS
          receive path into the PRBS31 test pattern mode described
          in [IEEE 802.3 Std.] subclause 50.3.8.2.  The value
          mixedFrequency(3) puts the WIS receive path into the mixed
          frequency test pattern mode described in [IEEE 802.3 Std.]
          subclause 50.3.8.3.  Any attempt to set this object to a
          value other than none(0) when the corresponding instance
          of ifAdminState has the value up(1) MUST be rejected with
          the error inconsistentValue, and any attempt to set the
          corresponding instance of ifAdminStatus to the value up(1)
          when an instance of this object has a value other than
          none(0) MUST be rejected with the error inconsistentValue."
       REFERENCE
          "[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
          checker, 45.2.2.6, 10G WIS Control 2 register (2.7), and
          45.2.2.7.2, PRBS31 pattern testing ability (2.8.1)."
        ::= { etherWisDeviceEntry 2 }








Expires 08/18/2002        Ethernet WIS Objects                 [Page 19]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


   etherWisDeviceRxTestPatternErrors OBJECT-TYPE
       SYNTAX  Gauge32 ( 0..65535 )
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
          "This object counts the number of errors detected when the
          WIS receive path is operating in the PRBS31 test pattern
          mode.  It is reset to zero when the WIS receive path
          initially enters that mode, and it increments each time
          the PRBS pattern checker detects an error as described in
          [IEEE 802.3 Std.] subclause 50.3.8.2 unless its value is
          65535, in which case it remains unchanged.  This object is
          writeable so that it may be reset upon explicit request
          of a command generator application while the WIS receive
          path continues to operate in PRBS31 test pattern mode."
       REFERENCE
          "[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
          checker, 45.2.2.7.2, PRBS31 pattern testing ability
          (2.8.1), and 45.2.2.8 10G WIS test pattern error counter
          register (2.9)."
        ::= { etherWisDeviceEntry 3 }






























Expires 08/18/2002        Ethernet WIS Objects                 [Page 20]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


   -- The Section group

   -- These objects provide WIS extensions to
   -- the SONET-MIB Section Group.

   etherWisSectionCurrentTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF EtherWisSectionCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "The table for the current state of Ethernet WIS sections."
        ::= { etherWisSection 1 }

   etherWisSectionCurrentEntry OBJECT-TYPE
       SYNTAX  EtherWisSectionCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "An entry in the etherWisSectionCurrentTable.  For each
          instance of this object there MUST be a corresponding
          instance of sonetSectionCurrentEntry."
       INDEX  { ifIndex }
        ::= { etherWisSectionCurrentTable 1 }

   EtherWisSectionCurrentEntry ::=
       SEQUENCE {
           etherWisSectionCurrentJ0Transmitted OCTET STRING,
           etherWisSectionCurrentJ0Received    OCTET STRING
           }

   etherWisSectionCurrentJ0Transmitted OBJECT-TYPE
       SYNTAX  OCTET STRING (SIZE (16))
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
          "This is the 16-octet section trace message that is
          to be transmitted in the J0 byte.  The value SHOULD
          be fifteen octets of '00'h followed by '89'h
          (or some cyclic shift thereof) when the section
          trace function is not used, and the implementation
          SHOULD use that value (or a cyclic shift thereof)
          as a default if no other value has been set."
       REFERENCE
          "[IEEE 802.3 Std.], 30.8.1.1.8, aJ0ValueTX."
        ::= { etherWisSectionCurrentEntry 1 }






Expires 08/18/2002        Ethernet WIS Objects                 [Page 21]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


   etherWisSectionCurrentJ0Received OBJECT-TYPE
       SYNTAX  OCTET STRING (SIZE (16))
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "This is the 16-octet section trace message that
          was most recently received in the J0 byte."
       REFERENCE
          "[IEEE 802.3 Std.], 30.8.1.1.9, aJ0ValueRX."
        ::= { etherWisSectionCurrentEntry 2 }


   -- The Path group

   -- These objects provide WIS extensions to
   -- the SONET-MIB Path Group.

   etherWisPathCurrentTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF EtherWisPathCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "The table for the current state of Ethernet WIS paths."
        ::= { etherWisPath 1 }

   etherWisPathCurrentEntry OBJECT-TYPE
       SYNTAX  EtherWisPathCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "An entry in the etherWisPathCurrentTable.  For each
          instance of this object there MUST be a corresponding
          instance of sonetPathCurrentEntry."
       INDEX  { ifIndex }
        ::= { etherWisPathCurrentTable 1 }

   EtherWisPathCurrentEntry ::=
       SEQUENCE {
           etherWisPathCurrentStatus           BITS,
           etherWisPathCurrentJ1Transmitted    OCTET STRING,
           etherWisPathCurrentJ1Received       OCTET STRING
           }









Expires 08/18/2002        Ethernet WIS Objects                 [Page 22]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


   etherWisPathCurrentStatus OBJECT-TYPE
       SYNTAX  BITS {
                   etherWisPathLOP(0),
                   etherWisPathAIS(1),
                   etherWisPathPLM(2),
                   etherWisPathLCD(3)
               }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
          "This variable indicates the current status of the
          path payload with a bit map that can indicate multiple
          defects at once.  The bit positions are assigned as
          follows:

          etherWisPathLOP(0)
             This bit is set to indicate that an
             LOP-P (Loss of Pointer - Path) defect
             is being experienced.  Note:  when this
             bit is set, sonetPathSTSLOP MUST be set
             in the corresponding instance of
             sonetPathCurrentStatus.

          etherWisPathAIS(1)
             This bit is set to indicate that an
             AIS-P (Alarm Indication Signal - Path)
             defect is being experienced.  Note:  when
             this bit is set, sonetPathSTSAIS MUST be
             set in the corresponding instance of
             sonetPathCurrentStatus.

          etherWisPathPLM(1)
             This bit is set to indicate that a
             PLM-P (Payload Label Mismatch - Path)
             defect is being experienced.  Note:  when
             this bit is set, sonetPathSignalLabelMismatch
             MUST be set in the corresponding instance of
             sonetPathCurrentStatus.

          etherWisPathLCD(3)
             This bit is set to indicate that an
             LCD-P (Loss of Codegroup Delination - Path)
             defect is being experienced.  Since this
             defect is detected by the PCS and not by
             the path layer itself, there is no
             corresponding bit in sonetPathCurrentStatus."
       REFERENCE
          "[IEEE 802.3 Std.], 30.8.1.1.18, aPathStatus."
        ::= { etherWisPathCurrentEntry 1 }


Expires 08/18/2002        Ethernet WIS Objects                 [Page 23]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


   etherWisPathCurrentJ1Transmitted OBJECT-TYPE
       SYNTAX  OCTET STRING (SIZE (16))
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
          "This is the 16-octet path trace message that is to
          be transmitted in the J1 byte.  The value SHOULD
          be fifteen octets of '00'h followed by '89'h
          (or some cyclic shift thereof) when the path
          trace function is not used, and the implementation
          SHOULD use that value (or a cyclic shift thereof)
          as a default if no other value has been set."
       REFERENCE
          "[IEEE 802.3 Std.], 30.8.1.1.23, aJ1ValueTX."
        ::= { etherWisPathCurrentEntry 2 }

   etherWisPathCurrentJ1Received OBJECT-TYPE
       SYNTAX  OCTET STRING (SIZE (16))
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
          "This is the 16-octet path trace message that
          was most recently received in the J1 byte."
       REFERENCE
          "[IEEE 802.3 Std.], 30.8.1.1.24, aJ1ValueRX."
        ::= { etherWisPathCurrentEntry 3 }


   -- The Far End Path group

   -- These objects provide WIS extensions to
   -- the SONET-MIB Far End Path Group.

   etherWisFarEndPathCurrentTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF EtherWisFarEndPathCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "The table for the current far-end state of Ethernet WIS
          paths."
        ::= { etherWisFarEndPath 1 }










Expires 08/18/2002        Ethernet WIS Objects                 [Page 24]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


   etherWisFarEndPathCurrentEntry OBJECT-TYPE
       SYNTAX  EtherWisFarEndPathCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
          "An entry in the etherWisFarEndPathCurrentTable.  For each
          instance of this object there MUST be a corresponding
          instance of sonetFarEndPathCurrentEntry."
       INDEX  { ifIndex }
        ::= { etherWisFarEndPathCurrentTable 1 }

   EtherWisFarEndPathCurrentEntry ::=
       SEQUENCE {
           etherWisFarEndPathCurrentStatus     BITS
           }

   etherWisFarEndPathCurrentStatus OBJECT-TYPE
       SYNTAX  BITS {
                   etherWisFarEndPayloadDefect(0),
                   etherWisFarEndServerDefect(1)
               }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
          "This variable indicates the current status at the
          far end of the path using a bit map that can indicate
          multiple defects at once.  The bit positions are
          assigned as follows:

          etherWisFarEndPayloadDefect(0)
             A far end payload defect (i.e., far end
             PLM-P or LCD-P) is currently being signalled
             in G1 bits 5-7.

          etherWisFarEndServerDefect(1)
             A far end server defect (i.e., far end
             LOP-P or AIS-P) is currently being signalled
             in G1 bits 5-7.  Note:  when this bit is set,
             sonetPathSTSRDI MUST be set in the corresponding
             instance of sonetPathCurrentStatus."
       REFERENCE
          "[IEEE 802.3 Std.], 30.8.1.1.25, aFarEndPathStatus."
        ::= { etherWisFarEndPathCurrentEntry 1 }








Expires 08/18/2002        Ethernet WIS Objects                 [Page 25]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


   --
   --     Conformance Statements
   --

   etherWisGroups      OBJECT IDENTIFIER ::= { etherWisConformance 1 }

   etherWisCompliances OBJECT IDENTIFIER ::= { etherWisConformance 2 }

   --     Object Groups

   etherWisDeviceGroupBasic OBJECT-GROUP
       OBJECTS {
           etherWisDeviceTxTestPatternMode,
           etherWisDeviceRxTestPatternMode
           }
       STATUS  current
       DESCRIPTION
          "A collection of objects that support test
          features required of all WIS devices."
        ::= { etherWisGroups 1 }

   etherWisDeviceGroupExtra OBJECT-GROUP
       OBJECTS {
           etherWisDeviceRxTestPatternErrors
           }
       STATUS  current
       DESCRIPTION
          "A collection of objects that support
          optional WIS device test features."
        ::= { etherWisGroups 2 }

   etherWisSectionGroup OBJECT-GROUP
       OBJECTS {
           etherWisSectionCurrentJ0Transmitted,
           etherWisSectionCurrentJ0Received
           }
       STATUS  current
       DESCRIPTION
          "A collection of objects that provide
          required information about a WIS section."
        ::= { etherWisGroups 3 }










Expires 08/18/2002        Ethernet WIS Objects                 [Page 26]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


   etherWisPathGroup OBJECT-GROUP
       OBJECTS {
           etherWisPathCurrentStatus,
           etherWisPathCurrentJ1Transmitted,
           etherWisPathCurrentJ1Received
           }
       STATUS  current
       DESCRIPTION
          "A collection of objects that provide
          required information about a WIS path."
        ::= { etherWisGroups 4 }

   etherWisFarEndPathGroup OBJECT-GROUP
       OBJECTS {
           etherWisFarEndPathCurrentStatus
           }
       STATUS  current
       DESCRIPTION
          "A collection of objects that provide required
          information about the far end of a WIS path."
        ::= { etherWisGroups 5 }

   --     Compliance Statements

   etherWisCompliance MODULE-COMPLIANCE
       STATUS  current
       DESCRIPTION
          "The compliance statement for this module."

       MODULE  -- this module
           MANDATORY-GROUPS {
               etherWisDeviceGroupBasic,
               etherWisSectionGroup,
               etherWisPathGroup,
               etherWisFarEndPathGroup
               }

           OBJECT      etherWisDeviceTxTestPatternMode
           SYNTAX      INTEGER {
               none(0),
               squareWave(1),
               mixedFrequency(3)
               }
           DESCRIPTION
               "Support for values other than none(0),
               squareWave(1), and mixedFrequency(3)
               is not required."




Expires 08/18/2002        Ethernet WIS Objects                 [Page 27]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


           OBJECT      etherWisDeviceRxTestPatternMode
           SYNTAX      INTEGER {
               none(0),
               mixedFrequency(3)
               }
           DESCRIPTION
               "Support for values other than none(0)
               and mixedFrequency(3) is not required."

           GROUP       etherWisDeviceGroupExtra
           DESCRIPTION
               "Implementation of this group, along with support for
               the value prbs31(2) for etherWisDeviceTxTestPatternMode
               and etherWisDeviceRxTestPatternMode, is necessary if the
               optional PRBS31 test pattern mode is to be supported."

       MODULE SONET-MIB
           MANDATORY-GROUPS {
               sonetMediumStuff2,
               sonetSectionStuff2,
               sonetLineStuff2,
               sonetFarEndLineStuff2,
               sonetPathStuff2,
               sonetFarEndPathStuff2
               }

           OBJECT      sonetMediumType
           SYNTAX      INTEGER {
               sonet(1)
               }
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required, nor is support
               for any value other than sonet(1)."

           OBJECT      sonetMediumLineCoding
           SYNTAX      INTEGER {
               sonetMediumNRZ(4)
               }
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required, nor is support
               for any value other than sonetMediumNRZ(4)."

           OBJECT      sonetMediumLineType
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required."



Expires 08/18/2002        Ethernet WIS Objects                 [Page 28]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


           OBJECT      sonetMediumCircuitIdentifier
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT      sonetMediumLoopbackConfig
           SYNTAX      BITS {
               sonetNoLoop(0),
               sonetFacilityLoop(1)
               }
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required, nor is support for values
               other than sonetNoLoop(0) and sonetFacilityLoop(1)."

           OBJECT      sonetSESthresholdSet
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required, and only one
               of the enumerated values need be supported."

           OBJECT      sonetPathCurrentWidth
           SYNTAX      INTEGER {
               sts192cSTM64(6)
               }
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required, nor is support
               for any value other than sts192cSTM64(6)."

        ::= { etherWisCompliances 1 }

   END


















Expires 08/18/2002        Ethernet WIS Objects                 [Page 29]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


5.  Acknowledgments

   This document is a product of the IETF Hubmib and AToMMIB Working
   Groups.  It builds upon the work of the IEEE P802.3ae 10 Gigabit
   Ethernet Task Force.

6.  Security Considerations

   There are a number of management objects defined in this MIB that
   have a MAX-ACCESS clause of read-write and/or read-create.  Such
   objects may be considered sensitive or vulnerable in some network
   environments.  The support for SET operations in a non-secure
   environment without proper protection can have a negative effect on
   network operations.

   SNMPv1 by itself is not a secure environment.  Even if the network
   itself is secure (for example by using IPSec), even then, there is no
   control as to who on the secure network is allowed to access and
   GET/SET (read/change/create/delete) the objects in this MIB.

   It is recommended that the implementers consider the security
   features as provided by the SNMPv3 framework.  Specifically, the use
   of the User-based Security Model RFC 2574 [RFC2574] and the View-
   based Access Control Model RFC 2575 [RFC2575] is recommended.

   It is then a customer/user responsibility to ensure that the SNMP
   entity giving access to an instance of this MIB, is properly
   configured to give access to the objects only to those principals
   (users) that have legitimate rights to indeed GET or SET
   (change/create/delete) them.





















Expires 08/18/2002        Ethernet WIS Objects                 [Page 30]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


7.  References

[RFC2571]   Harrington, D., Presuhn, R., and B. Wijnen, "An Architecture
            for Describing SNMP Management Frameworks", RFC 2571, April
            1999.

[RFC1155]   Rose, M., and K. McCloghrie, "Structure and Identification
            of Management Information for TCP/IP-based Internets", STD
            16, RFC 1155, May 1990.

[RFC1212]   Rose, M., and K. McCloghrie, "Concise MIB Definitions", STD
            16, RFC 1212, March 1991.

[RFC1215]   M. Rose, "A Convention for Defining Traps for use with the
            SNMP", RFC 1215, March 1991.

[RFC2578]   McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
            Rose, M., and S. Waldbusser, "Structure of Management
            Information Version 2 (SMIv2)", STD 58, RFC 2578, April
            1999.

[RFC2579]   McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
            Rose, M., and S. Waldbusser, "Textual Conventions for
            SMIv2", STD 58, RFC 2579, April 1999.

[RFC2580]   McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
            Rose, M., and S. Waldbusser, "Conformance Statements for
            SMIv2", STD 58, RFC 2580, April 1999.

[RFC1157]   Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple
            Network Management Protocol", STD 15, RFC 1157, May 1990.

[RFC1901]   Case, J., McCloghrie, K., Rose, M., and S. Waldbusser,
            "Introduction to Community-based SNMPv2", RFC 1901, January
            1996.

[RFC1906]   Case, J., McCloghrie, K., Rose, M., and S. Waldbusser,
            "Transport Mappings for Version 2 of the Simple Network
            Management Protocol (SNMPv2)", RFC 1906, January 1996.

[RFC2572]   Case, J., Harrington D., Presuhn R., and B. Wijnen, "Message
            Processing and Dispatching for the Simple Network Management
            Protocol (SNMP)", RFC 2572, April 1999.

[RFC2574]   Blumenthal, U., and B. Wijnen, "User-based Security Model
            (USM) for version 3 of the Simple Network Management
            Protocol (SNMPv3)", RFC 2574, April 1999.




Expires 08/18/2002        Ethernet WIS Objects                 [Page 31]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


[RFC1905]   Case, J., McCloghrie, K., Rose, M., and S. Waldbusser,
            "Protocol Operations for Version 2 of the Simple Network
            Management Protocol (SNMPv2)", RFC 1905, January 1996.

[RFC2573]   Levi, D., Meyer, P., and B. Stewart, "SNMPv3 Applications",
            RFC 2573, April 1999.

[RFC2575]   Wijnen, B., Presuhn, R., and K. McCloghrie, "View-based
            Access Control Model (VACM) for the Simple Network
            Management Protocol (SNMP)", RFC 2575, April 1999.

[RFC2570]   Case, J., Mundy, R., Partain, D., and B. Stewart,
            "Introduction to Version 3 of the Internet-standard Network
            Management Framework", RFC 2570, April 1999.

[RFC2119]   Bradner, S., "Key words for use in RFCs to Indicate
            Requirements Levels", BCP 14, RFC 2119, March 1997.

[RFC2863]   McCloghrie, K., and F. Kastenholz, "The Interfaces Group
            MIB", RFC 2863, June 2000.

[RFC2864]   McCloghrie, K., and G. Hanson, "The Inverted Stack Table
            Extension to the Interfaces Group MIB", RFC 2864, June 2000.

[SONETng]   Tesink, K., "Definitions of Managed Objects for the
            SONET/SDH Interface Type", <draft-ietf-atommib-rfc2558bis-
            00.txt>, work in progress.

[T1.231]    American National Standard for Telecommunications - Digital
            Hierarchy - Layer 1 In-Service Digital Transmission
            Performance Monitoring, ANSI T1.231-1997, September 1997.

[ETHERIF]   Flick, J., "Definitions of Managed Objects for the
            Ethernet-like Interface Types", <draft-ietf-hubmib-etherif-
            mib-v3-00.txt>, work in progress.

[MAU-MIB]   Flick, J., "Definitions of Managed Objects for IEEE 802.3
            Medium Attachment Units (MAUs)", <draft-ietf-hubmib-mau-
            mib-v3-00.txt>, work in progress.

[P802.3ae]  Law, D., Editor, Draft Supplement to IEEE Std. 802.3, IEEE
            Draft P802.3ae/D4.01, February 4, 2002, work in progress.









Expires 08/18/2002        Ethernet WIS Objects                 [Page 32]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


8.  Authors' Addresses

   Mike Ayers
   BMC Software, Inc.
   2141 North First Street
   San Jose, CA  95131
   USA

   Phone: +1 408 546 0947
   Fax:   +1 408 965 0359
   Email: mayers@bmc.com


   John Flick
   Hewlett-Packard Company
   8000 Foothills Blvd.  M/S 5557
   Roseville, CA 95747-5557

   Phone: +1 916 785 4018
   Fax:   +1 916 785 1199
   Email: johnf@rose.hp.com


   C. M. Heard
   600 Rainbow Dr. #141
   Mountain View, CA 94041-2542
   USA

   Phone: +1 650 964 8391
   EMail: heard@pobox.com


   Kam Lam
   Lucent Technologies
   101 Crawfords Corner Road, Room 4C-616A
   Holmdel, NJ 07733

   Phone: +1 732 949 8338
   EMail: hklam@lucent.com


   Kerry McDonald
   Institute for Applied Supercomputing
   California State University San Bernardino

   Email: kerry_mcd@hotmail.com
          kmcdonal@csci.csusb.edu




Expires 08/18/2002        Ethernet WIS Objects                 [Page 33]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


   K. C. Norseth
   Enterasys Networks
   2691 South Decker Lake Lane
   Salt Lake City, Utah 84119

   Phone: +1 801 887 9823
   Email: knorseth@enterasys.com


   Kaj Tesink
   Telcordia Technologies
   331 Newman Springs Road
   P.O. Box 7020
   Red Bank, NJ  07701-7020
   USA

   Phone: +1 732 758 5254
   EMail: kaj@research.telcordia.com

9.  Intellectual Property

   The IETF takes no position regarding the validity or scope of any
   intellectual property or other rights that might be claimed to
   pertain to the implementation or use of the technology described in
   this document or the extent to which any license under such rights
   might or might not be available;  neither does it represent that it
   has made any effort to identify any such rights.  Information on the
   IETF's procedures with respect to rights in standards-track and
   standards-related documentation can be found in BCP-11.  Copies of
   claims of rights made available for publication and any assurances of
   licenses to be made available, or the result of an attempt made to
   obtain a general license or permission for the use of such
   proprietary rights by implementors or users of this specification can
   be obtained from the IETF Secretariat.

   The IETF invites any interested party to bring to its attention any
   copyrights, patents or patent applications, or other proprietary
   rights which may cover technology that may be required to practice
   this standard.  Please address the information to the IETF Executive
   Director.











Expires 08/18/2002        Ethernet WIS Objects                 [Page 34]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


Appendix A:  Collection of Performance Data Using WIS MDIO Registers

   The purpose of this appendix is to illustrate how the WIS MDIO
   registers specified in [P802.3ae] subclause 45.2.2 (and more
   specifically the subset required by [P802.3ae] subclause 50.3.10) can
   be used to collect performance data either according to the
   conventions adopted by this document or according to the conventions
   specified in [P802.3ae] Clause 30.

   For an agent implementing the SNMP managed objects required by this
   document the first step in collecting WIS performance data would be
   to poll the 10G WIS Status 3 register and the various error count
   registers (10G WIS Section BIP Error Count, 10G WIS Line BIP Errors,
   10G WIS Far End Line BIP Errors, 10G WIS Path Block Error Count, and
   10G WIS Far End Path Block Error Count) once per second.  The 10G WIS
   Status 3 register bits are all latched until read and so would
   indicate whether a given defect occurred any time during the previous
   second.  The error count registers roll over modulo 2^16 or 2^32, and
   so to find the number of errors within the previous second the agent
   would need to subtract (modulo 2^16 or 2^32) the current reading from
   the reading taken one second ago.  Armed with that information, the
   agent could determine for any layer whether the one second interval
   was an errored second, a severely errored second (that requires
   comparison with a threshold unless a defect is present), or a
   severely errored frame second.  Determining whether a given second is
   or is not part of unavailable time requires additional logic;  the
   most straightforward and accurate method is the delay-line approach
   outlined in Appendix A of [SONETng].  With that information available
   the agent would be able to determine by how much each current count
   should be incremented (including effects of inhibiting).
   Implementations that conform to [T1.231] would end each 15-minute
   interval on time-of-day clock 1/4 hour boundaries;  if the delay-line
   approach is used then a time-of-day timestamp would accompany the
   one-second statistics.  At the end of each interval the current
   registers would be pushed onto the history stack and then would be
   cleared.  The xyxIntervalValidData flags would be set to False(2) if
   the number of samples was not between 890 and 910 or, in the case of
   far-end counts, if a near-end defect occurred during the just-
   completed interval (see [T1.231] Section 9.1.2.2 for details).

   An agent implementing the [P802.3ae] Clause 30 oWIS objects could
   start in much the same way, i.e., by polling the 10G WIS Status 3
   register and the various error count registers to find the defects
   and error counts for the previous second, and it could determine the
   number of errors and whether the second was an errored second, a
   severely errored second, or a severely errored frame second in the
   same manner as above.  The rest of the process would be simply to
   increment the generalized non-resetable counters without
   consideration of any inhibiting rules.


Expires 08/18/2002        Ethernet WIS Objects                 [Page 35]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


Full Copyright Statement

   Copyright (C) The Internet Society (2002).  All Rights Reserved.

   This document and translations of it may be copied and furnished to
   others, and derivative works that comment on or otherwise explain it
   or assist in its implementation may be prepared, copied, published
   and distributed, in whole or in part, without restriction of any
   kind, provided that the above copyright notice and this paragraph are
   included on all such copies and derivative works.  However, this
   document itself may not be modified in any way, such as by removing
   the copyright notice or references to the Internet Society or other
   Internet organizations, except as needed for the purpose of
   developing Internet standards in which case the procedures for
   copyrights defined in the Internet Standards process must be
   followed, or as required to translate it into languages other than
   English.

   The limited permissions granted above are perpetual and will not be
   revoked by the Internet Society or its successors or assigns.

   This document and the information contained herein is provided on an
   "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
   TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
   BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
   HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
   MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
























Expires 08/18/2002        Ethernet WIS Objects                 [Page 36]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


                             Revision History

   NOTE TO RFC Editor:  this section is to be removed prior to
   publication as an RFC.

   The following changes were made to <draft-ietf-hubmib-wis-mib-01.txt>
   to produce <draft-ietf-hubmib-wis-mib-02.txt>:

      1.) Section 3.1 was updated as agreed in "WIS MIB compliance
      statement issue" e-mail thread, specifically to explain that the
      ETHER-WIS compliance statement requires all objects that required
      by sonetCompliance2 as well as some that it leaves optional.

      2.) In Section 3.5 the paragraph dealing with STS-Path Remote
      Defect Indication was updated to indicate that an implementation
      of the WIS MIB (not necessarily an arbitrary implementation of the
      WIS) has to set the SONET-MIB's RDI status bit when a remote
      server defect is detected.

      3.) In Section 3.6 the text introducing the table of semantic
      differences between IEEE GDMO and SNMP objects was wordsmithed.

      4.) In Section 3.7 the mapping between objects in the
      etherWisDeviceTable and the station management registers was
      updated to reflect the updated MDIO register definitions in
      P802.3ae/D4.01 and the corresponding updates to the MIB objects.

      5.) In Section 3.8.1 the text was updated to state that the
      purpose of the etherWisDeviceTable is to support mandatory and
      optional WIS test features.

      6.) In Sections 3.8.1, 3.8.2, 3.8.3, and 3.8.4 certain instances
      of "SHALL" were changed to "MUST" to improve readability.

      7.) The LAST-UPDATED, ORGANIZATION, REVISION, and DESCRIPTION
      clauses of the MODULE-IDENTITY invocation were updated.

      8.) The lower-case "shall" in the DESCRIPTION clause of each table
      entry was changed to an uppercase "MUST", per RFC 2119, because it
      describes a requirement of the specification in the draft.

      9.) The etherWisDeviceTestPatternType objects was removed, and the
      objects etherWisDeviceTxTestPatternMode and
      etherWisDeviceRxTestPatternMode were changed from simple
      "enable/disable" flags to enumerations that reflect the specific
      text pattern mode in which the transmitter or receiver is
      operating.  A new optional object called
      etherWisDeviceRxTestPatternErrors was added to make visible the
      error count MDIO register contents when the receiver is operating


Expires 08/18/2002        Ethernet WIS Objects                 [Page 37]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


      in the (optional) PRBS31 test pattern mode added in D4.01.

      10.) The SYNTAX of etherWisSectionCurrentJ0Transmitted and
      etherWisSectionCurrentJ0Received was changed from INTEGER (0..255)
      to OCTET STRING (SIZE (16)) to reflect the change from 1-byte to
      16-byte section trace messages in D4.01, and the DESCRIPTION
      clauses were rewritten along the lines for those of the
      corresponding path trace objects.

      11.) In the DESCRIPTION of etherWisPathCurrentJ0Transmitted "path
      message" was changes to "path trace message".

      12.) etherWisDeviceGroup was split into a mandatory group
      etherWisDeviceGroupBasic and an optional group
      etherWisDeviceGroupExtra.

      13.) The compliance name was changed from
      etherWisCurrentCompliance to etherWisCompliance.

      14.) OBJECT clauses were added to specify required values for
      etherWisDeviceTxTestPatternMode and
      etherWisDeviceRxTestPatternMode.

      15.) A GROUP clause was added to state that
      etherWisDeviceGroupExtra needs to be implemented in order to
      support the PRBS31 test pattern mode.  The DESCRIPTION clause
      points out that the prbs31 enumeration is needed for
      etherWisDeviceTxTestPatternMode/etherWisDeviceRxTestPatternMode.

      16). References [SONETng] and [P802.3ae] references were updated
      to draft-ietf-atommib-rfc2558bis-00.txt and P802.3ae/D4.01,
      respectively.



















Expires 08/18/2002        Ethernet WIS Objects                 [Page 38]


Internet Draft     <draft-ietf-hubmib-wis-mib-02.txt>         02/18/2002


                              Table of Contents


      1 Abstract ..................................................    2
      2 The SNMP Management Framework .............................    2
      3 Overview ..................................................    3
      3.1 Relationship to the SONET MIB ...........................    4
      3.2 Relationship to the Ethernet-like Interfaces MIB ........    4
      3.3 Relationship to the 802.3 MAU MIB .......................    4
      3.4 Use of the ifTable ......................................    4
      3.4.1 Layering Model ........................................    5
      3.4.2    Use    of    ifTable    for     LLC     Layer/MAC
           Layer/Reconciliation     Sublayer/Physical     Coding
           Sublayer ...............................................    5
      3.4.3 Use of ifTable for SONET/SDH Path Layer ...............    5
      3.4.4 Use of  ifTable  for  SONET/SDH  Medium/Section/Line
           Layer ..................................................    5
      3.5 SONET/SDH Terminology ...................................    6
      3.6 Mapping of IEEE 802.3 Managed Objects ...................    7
      3.7 Mapping of SNMP  Objects  to  WIS  Station  Management
           Registers ..............................................   12
      3.8 Structure of the MIB Module .............................   14
      3.8.1 etherWisDeviceTable ...................................   14
      3.8.2 etherWisSectionCurrentTable ...........................   14
      3.8.3 etherWisPathCurrentTable ..............................   14
      3.8.4 etherWisFarEndPathCurrentTable ........................   15
      4 Object Definitions ........................................   16
      5 Acknowledgments ...........................................   30
      6 Security Considerations ...................................   30
      7 References ................................................   31
      8 Authors' Addresses ........................................   33
      9 Intellectual Property .....................................   34
       Appendix A:  Collection of  Performance  Data  Using  WIS
           MDIO Registers .........................................   35
       Full Copyright Statement ...................................   36
















Expires 08/18/2002        Ethernet WIS Objects                 [Page 39]