Internet Draft Keith McCloghrie
Cisco Systems, Inc
17 December 2004
Fibre Channel Management MIB
draft-ietf-ips-fcmgmt-mib-06.txt
Status of this Memo
By submitting this Internet-Draft, I certify that any applicable patent
or other IPR claims of which I am aware have been disclosed, and any of
which I become aware will be disclosed, in accordance with RFC 3668.
Internet-Drafts are working documents of the Internet Engineering Task
Force (IETF), its areas, and its working groups. Note that other groups
may also distribute working documents as Internet-Drafts.
Internet-Drafts are draft documents valid for a maximum of six months
and may be updated, replaced, or obsoleted by other documents at any
time. It is inappropriate to use Internet- Drafts as reference material
or to cite them other than as "work in progress".
The list of current Internet-Drafts can be accessed at
http://www.ietf.org/ietf/1id-abstracts.txt
The list of Internet-Draft Shadow Directories can be accessed at
http://www.ietf.org/shadow.html.
Copyright Notice
Copyright (C) The Internet Society (2004). All Rights Reserved.
Abstract
This memo defines a portion of the Management Information Base (MIB) for
use with network management protocols in the Internet community. In
particular, it describes managed objects for information related to
Fibre Channel.
Expires June 2005 [Page 1]
Internet Draft Fibre Channel Management MIB December 2004
Table of Contents
1 Introduction .................................................... 3
2 The Internet-Standard Management Framework ...................... 3
3 Short Overview of Fibre Channel ................................. 3
4 MIB Overview .................................................... 4
4.1 The fcmInstanceBasicGroup group ............................... 4
4.2 The fcmSwitchBasicGroup group ................................. 4
4.3 The fcmPortBasicGroup group ................................... 4
4.4 The fcmPortStatsGroup group ................................... 5
4.5 The fcmPortClass23StatsGroup group ............................ 5
4.6 The fcmPortLcStatsGroup group ................................. 5
4.7 The fcmPortClassFStatsGroup group ............................. 5
4.8 The fcmPortErrorsGroup group .................................. 5
4.9 The fcmSwitchPortGroup group .................................. 5
4.10 The fcmSwitchLoginGroup group ................................ 6
4.11 The fcmLinkBasicGroup group .................................. 6
5 Relationship to Other MIBs ...................................... 6
5.1 The Interfaces Group MIB ...................................... 6
5.2 Entity MIB .................................................... 9
5.3 Host Resources MIB ............................................ 10
6 Definitions ..................................................... 11
7 Intellectual Property ........................................... 63
8 Acknowledgements ................................................ 63
9 Normative References ............................................ 63
10 Informative References ......................................... 65
11 Security Considerations ........................................ 66
12 IANA Considerations ............................................ 67
12.1 OID Assignment ............................................... 67
12.2 FC Port Type Registry ........................................ 67
13 Comparison to draft-ietf-ipfc-fcmgmt-int-mib-07.txt ............ 70
14 Comparison to RFC 2837 ......................................... 77
15 Author's Address ............................................... 78
16 Full Copyright Statement ....................................... 78
Expires June 2005 [Page 2]
Internet Draft Fibre Channel Management MIB December 2004
1. Introduction
This memo defines a portion of the Management Information Base (MIB) for
use with network management protocols in the Internet community. In
particular, it describes managed objects for information related to
Fibre Channel.
2. The Internet-Standard Management Framework
For a detailed overview of the documents that describe the current
Internet-Standard Management Framework, please refer to section 7 of RFC
3410 [RFC3410].
Managed objects are accessed via a virtual information store, termed the
Management Information Base or MIB. MIB objects are generally accessed
through the Simple Network Management Protocol (SNMP). Objects in the
MIB are defined using the mechanisms defined in the Structure of
Management Information (SMI). This memo specifies a MIB module that is
compliant to the SMIv2, which is described in STD 58, RFC 2578
[RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580 [RFC2580].
3. Short Overview of Fibre Channel
The Fibre Channel (FC) is logically a bidirectional point-to-point
serial data channel, structured for high performance capability. The
Fibre Channel provides a general transport vehicle for higher level
protocols such as Intelligent Peripheral Interface (IPI) and Small
Computer System Interface (SCSI) command sets, the High-Performance
Parallel Interface (HIPPI) data framing, IP (Internet Protocol), IEEE
802.2, and others.
Physically, Fibre Channel is an interconnection of multiple
communication points, called N_Ports, interconnected either by a
switching network, called a Fabric, or by a point-to-point link. A
Fibre Channel "node" consists of one or more N_Ports. A Fabric may
consist of multiple Interconnect Elements, some of which are switches.
An N_Port connects to the Fabric via a port on a switch called an
F_Port. When multiple FC nodes are connected to a single port on a
switch via an "Arbitrated Loop" topology, the switch port is called an
FL_Port, and the nodes' ports are called NL_Ports. The term Nx_Port is
used to refer to either an N_Port or an NL_port. The term Fx_Port is
used to refer to either an F_Port or an FL_port. A switch port, which
is interconnected to another switch port via an Inter Element Link
(IEL), is called an E_Port. A B_Port connects a bridge device with an
E_Port on a switch; a B_Port provides a subset of E_Port functionality.
Expires June 2005 [Page 3]
Internet Draft Fibre Channel Management MIB December 2004
Many Fibre Channel components, including the fabric, each node, and most
ports, have globally-unique names. These globally-unique names are
typically formatted as World Wide Names (WWNs). More information on
WWNs can be found in [WWN1] and [WWN2]. WWNs are expected to be
persistent across agent and unit resets.
Fibre Channel frames contain 24-bit address identifiers which identify
the frame's source and destination ports. Each FC port has an address
identifier and a WWN. When a fabric is in use, the FC address
identifiers are dynamic and are assigned by a switch.
4. MIB Overview
This MIB contains the notion of a Fibre Channel management instance,
which is defined as a separable managed instance of Fibre Channel
functionality. Fibre Channel functionality may be grouped into Fibre
Channel management instances in whatever way is most convenient for the
implementation(s). For example, one such grouping accommodates a single
SNMP agent having multiple AgentX [RFC2741] sub-agents, with each sub-
agent implementing a different Fibre Channel management instance. In
order to represent such multiple Fibre Channel management instances
within the same SNMP context (see section 3.3.1 of [RFC3411]), all
tables in this MIB are INDEX-ed by fcmInstanceIndex which is defined as
an arbitrary integer to uniquely identify a particular Fibre Channel
management instance.
This MIB contains eleven MIB groups, as follows.
4.1. The fcmInstanceBasicGroup group
This group contains basic information about a Fibre Channel managed
instance, including its name and description, the Fibre Channel
function(s) it performs, and optional pointers to hardware and/or
software components.
4.2. The fcmSwitchBasicGroup group
This group contains basic information about a Fibre Channel switch,
including its domain-id and whether it is the principal switch of its
fabric.
4.3. The fcmPortBasicGroup group
This group contains basic information about a Fibre Channel port,
including its port name (WWN), the name of the node (if any) of which it
Expires June 2005 [Page 4]
Internet Draft Fibre Channel Management MIB December 2004
is a part, the type of port, the classes of service it supports, its
transmitter and connector types, and the higher level protocols it
supports.
Each Fibre Channel port is represented by an entry in the ifTable (see
below). The tables relating to ports in this MIB are indexed by the
port's value of ifIndex.
4.4. The fcmPortStatsGroup group
This group contains traffic statistics, which are not specific to any
particular class of service, for Fibre Channel ports.
4.5. The fcmPortClass23StatsGroup group
This group contains traffic statistics which are specific to Class 2 or
Class 3 traffic on Fibre Channel ports, including class-specific frame
and octet counters and counters of busy and reject frames.
4.6. The fcmPortLcStatsGroup group
Some of the statistics in the fcmPortClass23StatsGroup can increase
rapidly enough to warrant them being defined using the Counter64 syntax.
However, some old SNMP systems do not (yet) support Counter64 objects.
Thus, this group defines low-capacity (Counter32-based) equivalents for
the Counter64-based statistics in the fcmPortClass23StatsGroup group.
4.7. The fcmPortClassFStatsGroup group
This group contains traffic statistics which are specific to Class F
traffic on the E_Ports of a Fibre Channel switch.
4.8. The fcmPortErrorsGroup group
This group contains counters of various error conditions which can occur
on Fibre Channel ports.
4.9. The fcmSwitchPortGroup group
This group contains information about ports on a Fibre Channel switch.
For an Fx_Port, it includes the port's timeout values, its hold-time,
and its capabilities in terms of maximum and minimum buffer-to-buffer
credit allocations, maximum and minimum data field size, and support for
class 2 and class 3 sequenced delivery. For an E_Port or B_Port, it
includes the buffer-to-buffer credit allocation and data field size.
Expires June 2005 [Page 5]
Internet Draft Fibre Channel Management MIB December 2004
4.10. The fcmSwitchLoginGroup group
This group contains information, known to a Fibre Channel switch, about
its attached/logged-in Nx_Ports and the service parameters which have
been agreed with them.
4.11. The fcmLinkBasicGroup group
This group contains information, known to a local Fibre Channel
management instance, about Fibre Channel links, including links which
terminate locally.
5. Relationship to Other MIBs
This MIB is a replacement for two other MIBs: RFC 2837, and the Fibre
Channel Management Integration MIB which was originally submitted as an
Internet Draft to the IETF's IPFC Working Group as draft-ietf-ipfc-
fcmgmt-int-mib-0n.txt.
5.1. The Interfaces Group MIB
The Interfaces Group MIB [RFC2863] contains generic information about
all lower layer interfaces, i.e., interfaces which are (potentially)
below the internet layer. Thus, each Fibre Channel port should have its
own row in the ifTable, and that row will contain the generic
information about the interface/port. The Interfaces Group MIB
specifies that additional information which is specific to a particular
type of interface media, should be defined in a media-specific MIB.
This MIB is the media-specific MIB for Fibre Channel ports/interfaces.
Section 4 of [RFC2863] requires that a media-specific MIB clarify how
the generic definitions apply for the particular type of media. The
clarifications for Fibre Channel interfaces are as follows.
5.1.1. Layering Model
The Interfaces Group MIB permits multiple ifTable entries to be defined
for interface sub-layers, and for those multiple entries to be arranged
in a stack.
For Fibre Channel interfaces, no sublayers are defined and a Fibre
Channel interface will typically have no other ifTable rows stacked on
top of it, nor underneath it.
Expires June 2005 [Page 6]
Internet Draft Fibre Channel Management MIB December 2004
5.1.2. Virtual Circuits
This Fibre Channel MIB does not deal with virtual circuits.
5.1.3. ifRcvAddressTable
The ifRcvAddressTable does not apply to Fibre Channel interfaces.
5.1.4. ifType
The value of ifType for a Fibre Channel interface is 56.
5.1.5. ifXxxOctets
The definitions of ifInOctets and ifOutOctets (and similarly,
ifHCInOctets and ifHCOutOctets) specify that their values include
framing characters. For Fibre Channel interfaces, they include all the
octets contained in frames between the Start-of-Frame and End-of-Frame
delimiters (excluding the delimiters).
5.1.6. Specific Interface Group MIB Objects
The following table provides specific implementation guidelines for
applying the objects defined in the Interfaces Group MIB to Fibre
Channel interfaces. For those objects not listed here, refer to their
generic definitions in [RFC2863]. (RFC 2863 takes precedence over these
guidelines in the event of any conflict.)
Object Guidelines
ifType 56
ifMtu The MTU as seen by a higher layer
protocol, like IP. That is, when IP is
running over the interface, this object is
the size of the largest IP datagram that
can be sent/received over the interface.
ifSpeed For 1Gbs, this will be 1,000,000,000; for
2Gbs, it will be 2,000,000,000. If auto-
negotiation is implemented and enabled on
an interface, and the interface has not
yet negotiated to an operational speed,
this object SHOULD reflect the maximum
speed supported by the interface.
Expires June 2005 [Page 7]
Internet Draft Fibre Channel Management MIB December 2004
ifPhysAddress The interface's 24-bit Fibre Channel
Address Identifier, or the zero-length
string if no Address Identifier has been
assigned to the interface.
ifAdminStatus Write access is not required, and support
for 'testing' is not required.
ifOperStatus Support for 'testing' is not required.
The value 'dormant' has no meaning for
Fibre Channel interfaces.
ifInOctets The number of octets of information
ifHCInOctets contained in received frames between the
Start-of-Frame and End-of-Frame delimiters
(excluding the delimiters).
ifInUcastPkts The number of unicast frames received,
ifHCInUcastPkts i.e., the number of Start-of-Frame
delimiters received for unicast frames.
ifInErrors The sum for this interface of
fcmPortLossofSynchs
fcmPortLossofSignals
fcmPortPrimSeqProtocolErrors
fcmPortInvalidTxWords
fcmPortInvalidCRCs
fcmPortAddressErrors
fcmPortDelimiterErrors
fcmPortTruncatedFrames
fcmPortEncodingDisparityErrors
plus any errors in fcmPortOtherErrors
which were input errors.
ifOutOctets The number of octets of information
ifHCOutOctets contained in transmitted frames between
the Start-of-Frame and End-of-Frame
delimiters (excluding the delimiters).
ifOutUcastPkts The number of frames transmitted,
ifHCOutUcastPkts i.e., the number of start-of-frame
delimiters transmitted for unicast frames.
Expires June 2005 [Page 8]
Internet Draft Fibre Channel Management MIB December 2004
ifOutErrors This is the number of errors in
fcmPortOtherErrors which were output
errors.
ifInMulticastPkts These counters are not incremented
ifInBroadcastPkts (unless a proprietary mechanism for
ifOutMulticastPkts multicast/broadcast is supported).
ifOutBroadcastPkts
ifHCInMulticastPkts
ifHCInBroadcastPkts
ifHCOutMulticastPkts
ifHCOutBroadcastPkts
ifLinkUpDownTrapEnable Refer to [RFC2863]. Default is 'enabled'
ifHighSpeed The current operational speed of the
interface in millions of bits per second.
For 1Gbs, this will be 1000; for 2Gbs, it
will be 2000. If auto-negotiation is
implemented and enabled on an interface,
and the interface has not yet negotiated
to an operational speed, this object
SHOULD reflect the maximum speed supported
by the interface.
ifPromiscuousMode This will normally be 'false'
ifConnectorPresent This will normally be 'true'.
5.2. Entity MIB
The Entity MIB [RFC2737] contains information about individual physical
components and any hierarchical relationship which may exist between
them. Any Fibre Channel management instance with a relationship to a
physical component (or to a hierarchy of physical components) will have
its value of the fcmInstancePhysicalIndex object contain a pointer to
the relevant row in the Entity MIB. If there is no correspondence to a
physical component (or said component does not have a row in the Entity
MIB), then the value of fcmInstancePhysicalIndex is zero. (Note that an
implementation is not required to support a non-zero value of
fcmInstancePhysicalIndex.)
Expires June 2005 [Page 9]
Internet Draft Fibre Channel Management MIB December 2004
5.3. Host Resources MIB
The Host Resources MIB [RFC2790] includes information about installed
software modules. Any Fibre Channel management instance with a
correspondence to a software module, will have its value of the
fcmInstanceSoftwareIndex object contain a pointer to the relevant row in
the Host Resources MIB. If there is no correspondence to a software
module (or said software module does not has a row in the Host Resources
MIB), then the value of fcmInstanceSoftwareIndex is zero. (Note that an
agent implementation is not required to support a non-zero value of
fcmInstanceSoftwareIndex.)
Expires June 2005 [Page 10]
Internet Draft Fibre Channel Management MIB December 2004
6. Definitions
FC-MGMT-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32, Unsigned32, Counter32, Counter64, transmission
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
TruthValue, TEXTUAL-CONVENTION
FROM SNMPv2-TC
ifIndex FROM IF-MIB
SnmpAdminString FROM SNMP-FRAMEWORK-MIB;
fcMgmtMIB MODULE-IDENTITY
LAST-UPDATED "200412140000Z"
ORGANIZATION "IETF IPS (IP-Storage) Working Group"
CONTACT-INFO
" Keith McCloghrie
Cisco Systems, Inc.
Tel: +1 408 526-5260
E-mail: kzm@cisco.com
Postal: 170 West Tasman Drive
San Jose, CA USA 95134
"
DESCRIPTION
"This module defines management information specific to
Fibre Channel-attached devices.
Copyright (C) The Internet Society (2004). This version of
this MIB module is part of RFC yyyy; see the RFC itself for
full legal notices."
-- RFC Ed.: replace yyyy with actual RFC number & remove this note
REVISION "200412140000Z"
DESCRIPTION
"Initial version of the Fibre Channel Mgmt MIB module."
::= { transmission nnn } -- IANA, please enter the value you assign here
fcmgmtObjects OBJECT IDENTIFIER ::= { fcMgmtMIB 1 }
fcmgmtNotifications OBJECT IDENTIFIER ::= { fcMgmtMIB 2 }
fcmgmtNotifPrefix OBJECT IDENTIFIER ::= { fcmgmtNotifications 0 }
fcmgmtConformance OBJECT IDENTIFIER ::= { fcMgmtMIB 3 }
Expires June 2005 [Page 11]
Internet Draft Fibre Channel Management MIB December 2004
--********************************
-- Textual Conventions
--
FcNameIdOrZero ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The World Wide Name (WWN) associated with a Fibre Channel
(FC) entity. WWNs were initially defined as 64-bits in
length. The latest definition (for future use) is 128-bits
long. The zero-length string value is used in circumstances
where the WWN is unassigned/unknown."
SYNTAX OCTET STRING (SIZE(0 | 8 | 16))
FcAddressIdOrZero ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A Fibre Channel Address ID, a 24-bit value unique within
the address space of a Fabric. The zero-length string value
is used in circumstances where the WWN is
unassigned/unknown."
SYNTAX OCTET STRING (SIZE(0 | 3))
FcDomainIdOrZero ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The Domain Id (of a FC switch), or zero if the no Domain Id
has been assigned."
SYNTAX Integer32 (0..239)
FcPortType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The type of a Fibre Channel port, as indicated by the use
of the appropriate value assigned by IANA."
REFERENCE
"The IANA-maintained registry for
Fibre Channel port types. "
-- IANA, please extend the text inside the immediately
-- preceeding quotes to include a location at which a
-- reader can ascertain the latest assigned values
SYNTAX Unsigned32
Expires June 2005 [Page 12]
Internet Draft Fibre Channel Management MIB December 2004
FcClasses ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A set of Fibre Channel classes of service."
REFERENCE
"Classes of service are described in FC-FS Section 13."
SYNTAX BITS { classF(0), class1(1), class2(2), class3(3),
class4(4), class5(5), class6(6) }
FcBbCredit ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The buffer-to-buffer credit of an FC port."
SYNTAX Integer32 (0..32767)
FcBbCreditModel ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The buffer-to-buffer credit model of an Fx_Port."
SYNTAX INTEGER { regular(1), alternate (2) }
FcDataFieldSize ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The Receive Data Field Size associated with an FC port."
SYNTAX Integer32 (128..2112)
Expires June 2005 [Page 13]
Internet Draft Fibre Channel Management MIB December 2004
FcUnitFunctions ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A set of functions that a Fibre Channel Interconnect
Element or Platform might perform. A value with no bits
set, indicates the function(s) are unknown. The individual
bits have the following meanings:
other - none of the following.
hub - a device that interconnects L_Ports, but does not
operate as an FL_Port.
switch - a fabric element conforming to the Fibre Channel
switch fabric set of standards (e.g., FC-SW, FC-SW-2).
bridge - a device that encapsulates Fibre Channel frames
within another protocol (e.g., FC-BB, FC-BB-2).
gateway - a device that converts an FC-4 to another protocol
(e.g., FCP to iSCSI).
host - a computer system that provides end users services
such as computation and storage access.
storageSubsys - an integrated collection of storage
controllers, storage devices, and necessary software, that
provides storage services to one or more hosts.
storageAccessDev - a device that provides storage management
and access for heterogeneous hosts and heterogeneous devices
(e.g., medium changer).
nas - a device that connects to a network and provides file
access services.
wdmux - a device that modulates/demodulates each of several
data streams (e.g., Fibre Channel protocol data streams)
onto/from a different part of the light spectrum in an
optical fiber.
storageDevice - a disk/tape/etc. device (without the
controller and/or software required for it to be a
'storageSubsys')."
SYNTAX BITS {
Expires June 2005 [Page 14]
Internet Draft Fibre Channel Management MIB December 2004
other(0), -- none of the following
hub(1),
switch(2),
bridge(3),
gateway(4),
host(5),
storageSubsys(6),
storageAccessDev(7),
nas(8),
wdmux(9),
storageDevice(10)
}
Expires June 2005 [Page 15]
Internet Draft Fibre Channel Management MIB December 2004
--********************************
-- MIB object definitions
--
fcmInstanceTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcmInstanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about the local Fibre Channel management
instances."
::= { fcmgmtObjects 1 }
fcmInstanceEntry OBJECT-TYPE
SYNTAX FcmInstanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of attributes for a particular local Fibre Channel
management instance."
INDEX { fcmInstanceIndex }
::= { fcmInstanceTable 1 }
FcmInstanceEntry ::=
SEQUENCE {
fcmInstanceIndex Unsigned32,
fcmInstanceWwn FcNameIdOrZero,
fcmInstanceFunctions FcUnitFunctions,
fcmInstancePhysicalIndex Integer32,
fcmInstanceSoftwareIndex Integer32,
fcmInstanceStatus INTEGER,
fcmInstanceTextName SnmpAdminString,
fcmInstanceDescr SnmpAdminString,
fcmInstanceFabricId FcNameIdOrZero
}
fcmInstanceIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer value which uniquely identifies this
instance amongst all local Fibre Channel management
instances.
Expires June 2005 [Page 16]
Internet Draft Fibre Channel Management MIB December 2004
It is mandatory to keep this value constant between restarts
of the agent, and to make every possible effort to keep it
constant across restarts (but note, it is unrealistic to
expect it to remain constant across all re-configurations of
the local system, e.g., across the replacement of all non-
volatile storage)."
::= { fcmInstanceEntry 1 }
fcmInstanceWwn OBJECT-TYPE
SYNTAX FcNameIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the instance has one (or more) WWN(s), then this object
contains that (or one of those) WWN(s).
If the instance does not have a WWN associated with it, then
this object contains the zero-length string."
::= { fcmInstanceEntry 2 }
fcmInstanceFunctions OBJECT-TYPE
SYNTAX FcUnitFunctions
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"One (or more) Fibre Channel unit functions being performed
by this instance."
::= { fcmInstanceEntry 3 }
fcmInstancePhysicalIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If this management instance corresponds to a physical
component (or to a hierarchy of physical components)
identified by the Entity-MIB, then this object's value is
the value of the entPhysicalIndex of that component (or of
the component at the root of that hierarchy). If there is
no correspondence to a physical component (or no component
which has an entPhysicalIndex value), then the value of this
object is zero."
REFERENCE
"entPhysicalIndex is defined in the Entity MIB, RFC 2737."
::= { fcmInstanceEntry 4 }
Expires June 2005 [Page 17]
Internet Draft Fibre Channel Management MIB December 2004
fcmInstanceSoftwareIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If this management instance corresponds to an installed
software module identified in the Host Resources MIB, then
this object's value is the value of the hrSWInstalledIndex
of that module. If there is no correspondence to an
installed software module (or no module which has a
hrSWInstalledIndex value), then the value of this object is
zero."
REFERENCE
"hrSWInstalledIndex is defined in the Host Resources MIB,
RFC 2790"
::= { fcmInstanceEntry 5 }
fcmInstanceStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ok(2), -- able to operate correctly
warning(3), -- needs attention
failed(4) -- something has failed
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Overall status of the Fibre Channel entity/entities managed
by this management instance. The value should reflect the
most serious status of such entities."
::= { fcmInstanceEntry 6 }
fcmInstanceTextName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..79))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A textual name for this management instance and the Fibre
Channel entity/entities that it is managing."
::= { fcmInstanceEntry 7 }
fcmInstanceDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
Expires June 2005 [Page 18]
Internet Draft Fibre Channel Management MIB December 2004
DESCRIPTION
"A textual description of this management instance and the
Fibre Channel entity/entities that it is managing."
::= { fcmInstanceEntry 8 }
fcmInstanceFabricId OBJECT-TYPE
SYNTAX FcNameIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The globally unique Fabric Identifier which identifies the
fabric to which the Fibre Channel entity/entities managed by
this management instance are connected, or, of which they
are a part. This is typically the Node WWN of the principal
switch of a Fibre Channel fabric. The zero-length string
indicates that the fabric identifier is unknown (or not
applicable).
In the event that the Fibre Channel entity/entities managed
by this management instance is/are connected to multiple
fabrics, then this object records the first (known) one."
::= { fcmInstanceEntry 9 }
--********************************
-- The Fibre Channel Switch Table
--
fcmSwitchTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcmSwitchEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of information about Fibre Channel switches which
are managed by Fibre Channel management instances. Each
Fibre Channel management instance can manage one or more
Fibre Channel switches."
::= { fcmgmtObjects 2 }
fcmSwitchEntry OBJECT-TYPE
SYNTAX FcmSwitchEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular Fibre Channel switch which
Expires June 2005 [Page 19]
Internet Draft Fibre Channel Management MIB December 2004
is managed by the management instance given by
fcmInstanceIndex."
INDEX { fcmInstanceIndex, fcmSwitchIndex }
::= { fcmSwitchTable 1 }
FcmSwitchEntry ::=
SEQUENCE {
fcmSwitchIndex Unsigned32,
fcmSwitchDomainId FcDomainIdOrZero,
fcmSwitchPrincipal TruthValue,
fcmSwitchWWN FcNameIdOrZero
}
fcmSwitchIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer which uniquely identifies a Fibre
Channel switch amongst those managed by one Fibre Channel
management instance.
It is mandatory to keep this value constant between restarts
of the agent, and to make every possible effort to keep it
constant across restarts."
::= { fcmSwitchEntry 1 }
fcmSwitchDomainId OBJECT-TYPE
SYNTAX FcDomainIdOrZero
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Domain Id of this switch. A value of zero indicates
that a switch has not (yet) been assigned a Domain Id."
::= { fcmSwitchEntry 2 }
fcmSwitchPrincipal OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of whether this switch is the principal
switch within its fabric."
::= { fcmSwitchEntry 3 }
Expires June 2005 [Page 20]
Internet Draft Fibre Channel Management MIB December 2004
fcmSwitchWWN OBJECT-TYPE
SYNTAX FcNameIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The World Wide Name of this switch."
::= { fcmSwitchEntry 4 }
--********************************
-- The Fibre Channel Port Table
--
fcmPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcmPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about Fibre Channel ports. Each Fibre Channel
port is represented by one entry in the IF-MIB's ifTable."
REFERENCE
"RFC 2863, The Interfaces Group MIB, June 2000."
::= { fcmgmtObjects 3 }
fcmPortEntry OBJECT-TYPE
SYNTAX FcmPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry contains information about a specific port."
INDEX { ifIndex }
::= { fcmPortTable 1 }
FcmPortEntry ::=
SEQUENCE {
fcmPortInstanceIndex Unsigned32,
fcmPortWwn FcNameIdOrZero,
fcmPortNodeWwn FcNameIdOrZero,
fcmPortAdminType FcPortType,
fcmPortOperType FcPortType,
fcmPortFcCapClass FcClasses,
fcmPortFcOperClass FcClasses,
fcmPortTransmitterType INTEGER,
fcmPortConnectorType INTEGER,
fcmPortSerialNumber SnmpAdminString,
fcmPortPhysicalNumber Unsigned32,
Expires June 2005 [Page 21]
Internet Draft Fibre Channel Management MIB December 2004
fcmPortAdminSpeed INTEGER,
fcmPortCapProtocols BITS,
fcmPortOperProtocols BITS
}
fcmPortInstanceIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of fcmInstanceIndex by which the Fibre Channel
management instance, which manages this port, is identified
in the fcmInstanceTable."
::= { fcmPortEntry 1 }
fcmPortWwn OBJECT-TYPE
SYNTAX FcNameIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The World Wide Name of the port, or the zero-length string
if the port does not have a WWN."
::= { fcmPortEntry 2 }
fcmPortNodeWwn OBJECT-TYPE
SYNTAX FcNameIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The World Wide Name of the Node which contains this port,
or the zero-length string if the port does not have a node
WWN."
::= { fcmPortEntry 3 }
fcmPortAdminType OBJECT-TYPE
SYNTAX FcPortType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administratively desired type of this port."
::= { fcmPortEntry 4 }
fcmPortOperType OBJECT-TYPE
SYNTAX FcPortType
MAX-ACCESS read-only
Expires June 2005 [Page 22]
Internet Draft Fibre Channel Management MIB December 2004
STATUS current
DESCRIPTION
"The current operational type of this port."
::= { fcmPortEntry 5 }
fcmPortFcCapClass OBJECT-TYPE
SYNTAX FcClasses
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The classes of service capability of this port."
::= { fcmPortEntry 6 }
fcmPortFcOperClass OBJECT-TYPE
SYNTAX FcClasses
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The classes of service that are currently operational on
this port. For an FL_Port, this is the union of the classes
being supported across all attached NL_Ports."
::= { fcmPortEntry 7 }
fcmPortTransmitterType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
shortwave850nm(3),
longwave1550nm(4),
longwave1310nm(5),
electrical(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The technology of the port transceiver."
REFERENCE
"FC-GS-3, section 6.1.2.2.3"
::= { fcmPortEntry 8 }
fcmPortConnectorType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
gbic(3),
Expires June 2005 [Page 23]
Internet Draft Fibre Channel Management MIB December 2004
embedded(4),
glm(5),
gbicSerialId(6),
gbicNoSerialId(7),
sfpSerialId(8),
sfpNoSerialId(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The module type of the port connector. This object refers
to the hardware implementation of the port. It will be
'embedded' if the hardware equivalent to Gigabit interface
card (GBIC) is part of the line card and is unremovable. It
will be 'glm' if it's a gigabit link module (GLM). It will
be 'gbicSerialId' if the GBIC serial id can be read, else it
will be 'gbicNoSerialId'. It will be 'sfpSerialId', if the
small form factor (SFP) pluggable GBICs serial id can be
read, else it will be 'sfpNoSerialId'."
REFERENCE
"FC-GS-3, section 6.1.2.2.4"
::= { fcmPortEntry 9 }
fcmPortSerialNumber OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number associated with the port (e.g., for a
GBIC). If not applicable, the object's value is a zero-
length string."
REFERENCE
"FC-GS-3, section 6.1.2.2.4"
::= { fcmPortEntry 10 }
fcmPortPhysicalNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the port's 'Physical Port Number' as defined by
GS-3."
REFERENCE
"FC-GS-3, section 6.1.2.2.5"
::= { fcmPortEntry 11 }
Expires June 2005 [Page 24]
Internet Draft Fibre Channel Management MIB December 2004
fcmPortAdminSpeed OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
eighthGbs(2), -- 125Mbs
quarterGbs(3), -- 250Mbs
halfGbs(4), -- 500Mbs
oneGbs(5), -- 1Gbs
twoGbs(6), -- 2Gbs
fourGbs(7), -- 4Gbs
tenGbs(8) -- 10Gbs
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The speed of the interface:
'auto' - auto-negotiation
'tenGbs' - 10Gbs
'fourGbs' - 4Gbs
'twoGbs' - 2Gbs
'oneGbs' - 1Gbs
'halfGbs' - 500Mbs
'quarterGbs' - 250Mbs
'eighthGbs' - 125Mbs"
::= { fcmPortEntry 12 }
fcmPortCapProtocols OBJECT-TYPE
SYNTAX BITS {
unknown(0),
loop(1),
fabric(2),
scsi(3),
tcpIp(4),
vi(5),
ficon(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit mask specifying the higher level protocols which are
capable of being running over this port. Note that for
generic Fx_Ports, E_Ports and B_Ports, this object will
indicate all protocols."
::= { fcmPortEntry 13 }
Expires June 2005 [Page 25]
Internet Draft Fibre Channel Management MIB December 2004
fcmPortOperProtocols OBJECT-TYPE
SYNTAX BITS {
unknown(0),
loop(1),
fabric(2),
scsi(3),
tcpIp(4),
vi(5),
ficon(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit mask specifying the higher level protocols which are
currently operational on this port. For Fx_Ports, E_Ports
and B_Ports, this object will typically have the value
'unknown'."
::= { fcmPortEntry 14 }
--********************************
-- Port Statistics
--
fcmPortStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcmPortStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of statistics for Fibre Channel ports."
::= { fcmgmtObjects 4 }
fcmPortStatsEntry OBJECT-TYPE
SYNTAX FcmPortStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing statistics for a Fibre Channel port.
If any counter in this table suffers a discontinuity, the
value of ifCounterDiscontinuityTime (defined in the IF-MIB)
must be updated."
REFERENCE "The Interfaces Group MIB, RFC 2863, June 2000."
AUGMENTS { fcmPortEntry }
::= { fcmPortStatsTable 1 }
Expires June 2005 [Page 26]
Internet Draft Fibre Channel Management MIB December 2004
FcmPortStatsEntry ::=
SEQUENCE {
fcmPortBBCreditZeros Counter64,
fcmPortFullInputBuffers Counter64,
fcmPortClass2RxFrames Counter64,
fcmPortClass2RxOctets Counter64,
fcmPortClass2TxFrames Counter64,
fcmPortClass2TxOctets Counter64,
fcmPortClass2Discards Counter64,
fcmPortClass2RxFbsyFrames Counter64,
fcmPortClass2RxPbsyFrames Counter64,
fcmPortClass2RxFrjtFrames Counter64,
fcmPortClass2RxPrjtFrames Counter64,
fcmPortClass2TxFbsyFrames Counter64,
fcmPortClass2TxPbsyFrames Counter64,
fcmPortClass2TxFrjtFrames Counter64,
fcmPortClass2TxPrjtFrames Counter64,
fcmPortClass3RxFrames Counter64,
fcmPortClass3RxOctets Counter64,
fcmPortClass3TxFrames Counter64,
fcmPortClass3TxOctets Counter64,
fcmPortClass3Discards Counter64,
fcmPortClassFRxFrames Counter32,
fcmPortClassFRxOctets Counter32,
fcmPortClassFTxFrames Counter32,
fcmPortClassFTxOctets Counter32,
fcmPortClassFDiscards Counter32
}
fcmPortBBCreditZeros OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transitions in/out of the buffer-to-buffer
credit zero state. The other side is not providing any
credit."
::= { fcmPortStatsEntry 1 }
fcmPortFullInputBuffers OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of occurrences when all input buffers of a port
Expires June 2005 [Page 27]
Internet Draft Fibre Channel Management MIB December 2004
were full and outbound buffer-to-buffer credit transitioned
to zero, i.e., there became no credit to provide to other
side."
::= { fcmPortStatsEntry 2 }
fcmPortClass2RxFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Class 2 frames received at this port."
::= { fcmPortStatsEntry 3 }
fcmPortClass2RxOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets contained in Class 2 frames received
at this port."
::= { fcmPortStatsEntry 4 }
fcmPortClass2TxFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Class 2 frames transmitted out of this port."
::= { fcmPortStatsEntry 5 }
fcmPortClass2TxOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets contained in Class 2 frames
transmitted out of this port."
::= { fcmPortStatsEntry 6 }
fcmPortClass2Discards OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Class 2 frames that were discarded upon
Expires June 2005 [Page 28]
Internet Draft Fibre Channel Management MIB December 2004
reception at this port."
::= { fcmPortStatsEntry 7 }
fcmPortClass2RxFbsyFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that F_BSY was returned to this port as
a result of a Class 2 frame that could not be delivered to
the other end of the link. This can occur when either the
fabric or the destination port is temporarily busy. Note
that this counter will never increment for an F_Port."
::= { fcmPortStatsEntry 8 }
fcmPortClass2RxPbsyFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that P_BSY was returned to this port as
a result of a Class 2 frame that could not be delivered to
the other end of the link. This can occur when the
destination port is temporarily busy."
::= { fcmPortStatsEntry 9 }
fcmPortClass2RxFrjtFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that F_RJT was returned to this port as
a result of a Class 2 frame that was rejected by the fabric.
Note that this counter will never increment for an F_Port."
::= { fcmPortStatsEntry 10 }
fcmPortClass2RxPrjtFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that P_RJT was returned to this port as
a result of a Class 2 frame that was rejected at the
destination N_Port."
::= { fcmPortStatsEntry 11 }
Expires June 2005 [Page 29]
Internet Draft Fibre Channel Management MIB December 2004
fcmPortClass2TxFbsyFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that F_BSY was generated by this port
as a result of a Class 2 frame that could not be delivered
because either the Fabric or the destination port was
temporarily busy. Note that this counter will never
increment for an N_Port."
::= { fcmPortStatsEntry 12 }
fcmPortClass2TxPbsyFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that P_BSY was generated by this port
as a result of a Class 2 frame that could not be delivered
because the destination port was temporarily busy. Note
that this counter will never increment for an F_Port."
::= { fcmPortStatsEntry 13 }
fcmPortClass2TxFrjtFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that F_RJT was generated by this port
as a result of a Class 2 frame being rejected by the fabric.
Note that this counter will never increment for an N_Port."
::= { fcmPortStatsEntry 14 }
fcmPortClass2TxPrjtFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that P_RJT was generated by this port
as a result of a Class 2 frame being rejected at the
destination N_Port. Note that this counter will never
increment for an F_Port."
::= { fcmPortStatsEntry 15 }
fcmPortClass3RxFrames OBJECT-TYPE
Expires June 2005 [Page 30]
Internet Draft Fibre Channel Management MIB December 2004
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Class 3 frames received at this port."
::= { fcmPortStatsEntry 16 }
fcmPortClass3RxOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets contained in Class 3 frames received
at this port."
::= { fcmPortStatsEntry 17 }
fcmPortClass3TxFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Class 3 frames transmitted out of this port."
::= { fcmPortStatsEntry 18 }
fcmPortClass3TxOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets contained in Class 3 frames
transmitted out of this port."
::= { fcmPortStatsEntry 19 }
fcmPortClass3Discards OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Class 3 frames that were discarded upon
reception at this port."
::= { fcmPortStatsEntry 20 }
fcmPortClassFRxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
Expires June 2005 [Page 31]
Internet Draft Fibre Channel Management MIB December 2004
STATUS current
DESCRIPTION
"The number of Class F frames received at this port."
::= { fcmPortStatsEntry 21 }
fcmPortClassFRxOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets contained in Class F frames received
at this port."
::= { fcmPortStatsEntry 22 }
fcmPortClassFTxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Class F frames transmitted out of this port."
::= { fcmPortStatsEntry 23 }
fcmPortClassFTxOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets contained in Class F frames
transmitted out of this port."
::= { fcmPortStatsEntry 24 }
fcmPortClassFDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Class F frames that were discarded upon
reception at this port."
::= { fcmPortStatsEntry 25 }
--********************************
-- Port Low-capacity Statistics
--
-- these are Counter32 "low-capacity" counters for systems
Expires June 2005 [Page 32]
Internet Draft Fibre Channel Management MIB December 2004
-- which do not support Counter64's
fcmPortLcStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcmPortLcStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Counter32-based statistics for systems which do
not support Counter64."
::= { fcmgmtObjects 5 }
fcmPortLcStatsEntry OBJECT-TYPE
SYNTAX FcmPortLcStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing low-capacity (i.e., based on Counter32)
statistics for a Fibre Channel port. If any counter in this
table suffers a discontinuity, the value of
ifCounterDiscontinuityTime (defined in the IF-MIB) must be
updated."
REFERENCE "The Interfaces Group MIB, RFC 2863, June 2000."
AUGMENTS { fcmPortEntry }
::= { fcmPortLcStatsTable 1 }
FcmPortLcStatsEntry ::=
SEQUENCE {
fcmPortLcBBCreditZeros Counter32,
fcmPortLcFullInputBuffers Counter32,
fcmPortLcClass2RxFrames Counter32,
fcmPortLcClass2RxOctets Counter32,
fcmPortLcClass2TxFrames Counter32,
fcmPortLcClass2TxOctets Counter32,
fcmPortLcClass2Discards Counter32,
fcmPortLcClass2RxFbsyFrames Counter32,
fcmPortLcClass2RxPbsyFrames Counter32,
fcmPortLcClass2RxFrjtFrames Counter32,
fcmPortLcClass2RxPrjtFrames Counter32,
fcmPortLcClass2TxFbsyFrames Counter32,
fcmPortLcClass2TxPbsyFrames Counter32,
fcmPortLcClass2TxFrjtFrames Counter32,
fcmPortLcClass2TxPrjtFrames Counter32,
fcmPortLcClass3RxFrames Counter32,
fcmPortLcClass3RxOctets Counter32,
fcmPortLcClass3TxFrames Counter32,
Expires June 2005 [Page 33]
Internet Draft Fibre Channel Management MIB December 2004
fcmPortLcClass3TxOctets Counter32,
fcmPortLcClass3Discards Counter32
}
fcmPortLcBBCreditZeros OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transitions in/out of the buffer-to-buffer
credit zero state. The other side is not providing any
credit."
::= { fcmPortLcStatsEntry 1 }
fcmPortLcFullInputBuffers OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of occurrences when all input buffers of a port
were full and outbound buffer-to-buffer credit transitioned
to zero, i.e., there became no credit to provide to other
side."
::= { fcmPortLcStatsEntry 2 }
fcmPortLcClass2RxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Class 2 frames received at this port."
::= { fcmPortLcStatsEntry 3 }
fcmPortLcClass2RxOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets contained in Class 2 frames received
at this port."
::= { fcmPortLcStatsEntry 4 }
fcmPortLcClass2TxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
Expires June 2005 [Page 34]
Internet Draft Fibre Channel Management MIB December 2004
STATUS current
DESCRIPTION
"The number of Class 2 frames transmitted out of this port."
::= { fcmPortLcStatsEntry 5 }
fcmPortLcClass2TxOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets contained in Class 2 frames
transmitted out of this port."
::= { fcmPortLcStatsEntry 6 }
fcmPortLcClass2Discards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Class 2 frames that were discarded upon
reception at this port."
::= { fcmPortLcStatsEntry 7 }
fcmPortLcClass2RxFbsyFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that F_BSY was returned to this port as
a result of a Class 2 frame that could not be delivered to
the other end of the link. This can occur when either the
fabric or the destination port is temporarily busy. Note
that this counter will never increment for an F_Port."
::= { fcmPortLcStatsEntry 8 }
fcmPortLcClass2RxPbsyFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that P_BSY was returned to this port as
a result of a Class 2 frame that could not be delivered to
the other end of the link. This can occur when the
destination port is temporarily busy."
::= { fcmPortLcStatsEntry 9 }
Expires June 2005 [Page 35]
Internet Draft Fibre Channel Management MIB December 2004
fcmPortLcClass2RxFrjtFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that F_RJT was returned to this port as
a result of a Class 2 frame that was rejected by the fabric.
Note that this counter will never increment for an F_Port."
::= { fcmPortLcStatsEntry 10 }
fcmPortLcClass2RxPrjtFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that P_RJT was returned to this port as
a result of a Class 2 frame that was rejected at the
destination N_Port."
::= { fcmPortLcStatsEntry 11 }
fcmPortLcClass2TxFbsyFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that F_BSY was generated by this port
as a result of a Class 2 frame that could not be delivered
because either the Fabric or the destination port was
temporarily busy. Note that this counter will never
increment for an N_Port."
::= { fcmPortLcStatsEntry 12 }
fcmPortLcClass2TxPbsyFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that P_BSY was generated by this port
as a result of a Class 2 frame that could not be delivered
because the destination port was temporarily busy. Note
that this counter will never increment for an F_Port."
::= { fcmPortLcStatsEntry 13 }
fcmPortLcClass2TxFrjtFrames OBJECT-TYPE
SYNTAX Counter32
Expires June 2005 [Page 36]
Internet Draft Fibre Channel Management MIB December 2004
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that F_RJT was generated by this port
as a result of a Class 2 frame being rejected by the fabric.
Note that this counter will never increment for an N_Port."
::= { fcmPortLcStatsEntry 14 }
fcmPortLcClass2TxPrjtFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times that P_RJT was generated by this port
as a result of a Class 2 frame being rejected at the
destination N_Port. Note that this counter will never
increment for an F_Port."
::= { fcmPortLcStatsEntry 15 }
fcmPortLcClass3RxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Class 3 frames received at this port."
::= { fcmPortLcStatsEntry 16 }
fcmPortLcClass3RxOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets contained in Class 3 frames received
at this port."
::= { fcmPortLcStatsEntry 17 }
fcmPortLcClass3TxFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Class 3 frames transmitted out of this port."
::= { fcmPortLcStatsEntry 18 }
fcmPortLcClass3TxOctets OBJECT-TYPE
Expires June 2005 [Page 37]
Internet Draft Fibre Channel Management MIB December 2004
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets contained in Class 3 frames
transmitted out of this port."
::= { fcmPortLcStatsEntry 19 }
fcmPortLcClass3Discards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Class 3 frames that were discarded upon
reception at this port."
::= { fcmPortLcStatsEntry 20 }
--********************************
-- Port Error Counters
--
fcmPortErrorsTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcmPortErrorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Error counters for Fibre Channel ports."
::= { fcmgmtObjects 6 }
fcmPortErrorsEntry OBJECT-TYPE
SYNTAX FcmPortErrorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Error counters for a Fibre Channel port. If any counter in
this table suffers a discontinuity, the value of
ifCounterDiscontinuityTime (defined in the IF-MIB) must be
updated."
REFERENCE "The Interfaces Group MIB, RFC 2863, June 2000."
AUGMENTS { fcmPortEntry }
::= { fcmPortErrorsTable 1 }
FcmPortErrorsEntry ::=
SEQUENCE {
Expires June 2005 [Page 38]
Internet Draft Fibre Channel Management MIB December 2004
fcmPortRxLinkResets Counter32,
fcmPortTxLinkResets Counter32,
fcmPortLinkResets Counter32,
fcmPortRxOfflineSequences Counter32,
fcmPortTxOfflineSequences Counter32,
fcmPortLinkFailures Counter32,
fcmPortLossofSynchs Counter32,
fcmPortLossofSignals Counter32,
fcmPortPrimSeqProtocolErrors Counter32,
fcmPortInvalidTxWords Counter32,
fcmPortInvalidCRCs Counter32,
fcmPortInvalidOrderedSets Counter32,
fcmPortFrameTooLongs Counter32,
fcmPortTruncatedFrames Counter32,
fcmPortAddressErrors Counter32,
fcmPortDelimiterErrors Counter32,
fcmPortEncodingDisparityErrors Counter32,
fcmPortOtherErrors Counter32
}
fcmPortRxLinkResets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Link Reset (LR) Primitive Sequences
received."
::= { fcmPortErrorsEntry 1 }
fcmPortTxLinkResets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Link Reset (LR) Primitive Sequences
transmitted."
::= { fcmPortErrorsEntry 2 }
fcmPortLinkResets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the reset link protocol was initiated
on this port. This includes the number of Loop
Expires June 2005 [Page 39]
Internet Draft Fibre Channel Management MIB December 2004
Initialization Primitive (LIP) events on an arbitrated loop
port."
::= { fcmPortErrorsEntry 3 }
fcmPortRxOfflineSequences OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Offline (OLS) Primitive Sequences received at
this port."
::= { fcmPortErrorsEntry 4 }
fcmPortTxOfflineSequences OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Offline (OLS) Primitive Sequences transmitted
by this port."
::= { fcmPortErrorsEntry 5 }
fcmPortLinkFailures OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of link failures. This count is part of FC-PH's
Link Error Status Block (LESB)."
REFERENCE
"FC-PH, rev 4.3, 1 June 1994, section 29.8."
::= { fcmPortErrorsEntry 6 }
fcmPortLossofSynchs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of instances of synchronization loss detected at
this port. This count is part of FC-PH's Link Error Status
Block (LESB)."
REFERENCE
"FC-PH, rev 4.3, 1 June 1994, section 29.8."
::= { fcmPortErrorsEntry 7 }
Expires June 2005 [Page 40]
Internet Draft Fibre Channel Management MIB December 2004
fcmPortLossofSignals OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of instances of signal loss detected at this
port. This count is part of FC-PH's Link Error Status Block
(LESB)."
REFERENCE
"FC-PH, rev 4.3, 1 June 1994, section 29.8."
::= { fcmPortErrorsEntry 8 }
fcmPortPrimSeqProtocolErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of primitive sequence protocol errors detected
at this port. This count is part of FC-PH's Link Error
Status Block (LESB)."
REFERENCE
"FC-PH, rev 4.3, 1 June 1994, section 29.8."
::= { fcmPortErrorsEntry 9 }
fcmPortInvalidTxWords OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of invalid transmission words received at this
port. This count is part of FC-PH's Link Error Status Block
(LESB)."
REFERENCE
"FC-PH, rev 4.3, 1 June 1994, section 29.8."
::= { fcmPortErrorsEntry 10 }
fcmPortInvalidCRCs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received with invalid CRC. This count
is part of FC-PH's Link Error Status Block (LESB)."
REFERENCE
"FC-PH, rev 4.3, 1 June 1994, section 29.8."
Expires June 2005 [Page 41]
Internet Draft Fibre Channel Management MIB December 2004
::= { fcmPortErrorsEntry 11 }
fcmPortInvalidOrderedSets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of invalid ordered sets received at this port."
::= { fcmPortErrorsEntry 12 }
fcmPortFrameTooLongs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received at this port where the frame
length was greater than what was agreed to in FLOGI/PLOGI.
This could be caused by losing the end of frame delimiter."
::= { fcmPortErrorsEntry 13 }
fcmPortTruncatedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received at this port where the frame
length was less than the minimum indicated by the frame
header - normally 24 bytes, but it could be more if the
DFCTL field indicates an optional header should have been
present."
::= { fcmPortErrorsEntry 14 }
fcmPortAddressErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received with unknown addressing; for
example, an unknown SID or DID."
::= { fcmPortErrorsEntry 15 }
fcmPortDelimiterErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
Expires June 2005 [Page 42]
Internet Draft Fibre Channel Management MIB December 2004
DESCRIPTION
"The number of invalid frame delimiters received at this
port. An example is a frame with a class 2 start and a class
3 at the end."
::= { fcmPortErrorsEntry 16 }
fcmPortEncodingDisparityErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of encoding disparity errors received at this
port."
::= { fcmPortErrorsEntry 17 }
fcmPortOtherErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of errors which were detected on this port but
which were not counted by any other error counter in this
row."
::= { fcmPortErrorsEntry 18 }
Expires June 2005 [Page 43]
Internet Draft Fibre Channel Management MIB December 2004
--********************************
-- The Fibre Channel Fx_Port Table
--
fcmFxPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcmFxPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Additional information about Fibre Channel ports which is
specific to Fx_Ports. This table will contain one entry for
each fcmPortTable entry which represents an Fx_Port."
::= { fcmgmtObjects 7 }
fcmFxPortEntry OBJECT-TYPE
SYNTAX FcmFxPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry contains information about a specific Fx_Port."
INDEX { ifIndex }
::= { fcmFxPortTable 1 }
FcmFxPortEntry ::=
SEQUENCE {
fcmFxPortRatov Unsigned32,
fcmFxPortEdtov Unsigned32,
fcmFxPortRttov Unsigned32,
fcmFxPortHoldTime Unsigned32,
fcmFxPortCapBbCreditMax FcBbCredit,
fcmFxPortCapBbCreditMin FcBbCredit,
fcmFxPortCapDataFieldSizeMax FcDataFieldSize,
fcmFxPortCapDataFieldSizeMin FcDataFieldSize,
fcmFxPortCapClass2SeqDeliv TruthValue,
fcmFxPortCapClass3SeqDeliv TruthValue,
fcmFxPortCapHoldTimeMax Unsigned32,
fcmFxPortCapHoldTimeMin Unsigned32
}
fcmFxPortRatov OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
Expires June 2005 [Page 44]
Internet Draft Fibre Channel Management MIB December 2004
"The Resource_Allocation_Timeout Value configured for this
Fx_Port. This is used as the timeout value for determining
when to reuse an Nx_Port resource such as a
Recovery_Qualifier. It represents the Error_Detect_Timeout
value (see fcmFxPortEdtov) plus twice the maximum time that
a frame may be delayed within the Fabric and still be
delivered."
::= { fcmFxPortEntry 1 }
fcmFxPortEdtov OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Error_Detect_Timeout value configured for this Fx_Port.
This is used as the timeout value for detecting an error
condition."
::= { fcmFxPortEntry 2 }
fcmFxPortRttov OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Receiver_Transmitter_Timeout value of this Fx_Port.
This is used by the receiver logic to detect Loss of
Synchronization."
::= { fcmFxPortEntry 3 }
fcmFxPortHoldTime OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum time that this Fx_Port shall hold a frame
before discarding the frame if it is unable to deliver the
frame. The value 0 means that this Fx_Port does not support
this parameter."
::= { fcmFxPortEntry 4 }
fcmFxPortCapBbCreditMax OBJECT-TYPE
SYNTAX FcBbCredit
Expires June 2005 [Page 45]
Internet Draft Fibre Channel Management MIB December 2004
UNITS "buffers"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of receive buffers which this port is
capable of making available for holding frames from attached
Nx_Port(s)."
::= { fcmFxPortEntry 5 }
fcmFxPortCapBbCreditMin OBJECT-TYPE
SYNTAX FcBbCredit
UNITS "buffers"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum number of receive buffers which this port is
capable of making available for holding frames from attached
Nx_Port(s)."
::= { fcmFxPortEntry 6 }
fcmFxPortCapDataFieldSizeMax OBJECT-TYPE
SYNTAX FcDataFieldSize
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum size in bytes of the Data Field in a frame that
this Fx_Port is capable of receiving from an attached
Nx_Port."
::= { fcmFxPortEntry 7 }
fcmFxPortCapDataFieldSizeMin OBJECT-TYPE
SYNTAX FcDataFieldSize
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum size in bytes of the Data Field in a frame that
this Fx_Port is capable of receiving from an attached
Nx_Port."
::= { fcmFxPortEntry 8 }
fcmFxPortCapClass2SeqDeliv OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
Expires June 2005 [Page 46]
Internet Draft Fibre Channel Management MIB December 2004
STATUS current
DESCRIPTION
"An indication of whether this Fx_Port is capable of
supporting Class 2 Sequential Delivery."
::= { fcmFxPortEntry 9 }
fcmFxPortCapClass3SeqDeliv OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of whether this Fx_Port is capable of
supporting Class 3 Sequential Delivery."
::= { fcmFxPortEntry 10 }
fcmFxPortCapHoldTimeMax OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum holding time that this Fx_Port is capable of
supporting."
::= { fcmFxPortEntry 11 }
fcmFxPortCapHoldTimeMin OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum holding time that this Fx_Port is capable of
supporting."
::= { fcmFxPortEntry 12 }
Expires June 2005 [Page 47]
Internet Draft Fibre Channel Management MIB December 2004
--********************************
-- The Fibre Channel Inter-Switch Port Table
--
fcmISPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcmISPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Additional information about E_Ports, B_Ports, and any
other type of Fibre Channel port to which inter-switch links
can be connected. This table will contain one entry for
each fcmPortTable entry which represents such a port."
::= { fcmgmtObjects 8 }
fcmISPortEntry OBJECT-TYPE
SYNTAX FcmISPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry contains information about a specific port
connected to an inter-switch link."
INDEX { ifIndex }
::= { fcmISPortTable 1 }
FcmISPortEntry ::=
SEQUENCE {
fcmISPortClassFCredit FcBbCredit,
fcmISPortClassFDataFieldSize FcDataFieldSize
}
fcmISPortClassFCredit OBJECT-TYPE
SYNTAX FcBbCredit
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of Class F data frames which can be
transmitted by the inter-switch port without receipt of ACK
or Link_Response frames."
::= { fcmISPortEntry 1 }
fcmISPortClassFDataFieldSize OBJECT-TYPE
SYNTAX FcDataFieldSize
UNITS "bytes"
MAX-ACCESS read-only
Expires June 2005 [Page 48]
Internet Draft Fibre Channel Management MIB December 2004
STATUS current
DESCRIPTION
"The Receive Data Field Size which the inter-switch port has
agreed to support for Class F frames to/from this port. The
size specifies the largest Data Field Size for an FT_1
frame."
::= { fcmISPortEntry 2 }
--********************************
-- The Fabric Login table
--
-- This table contains the information held by FC switches
-- about the Nx_Ports which are logged-in/attached to their
-- Fx_Ports
fcmFLoginTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcmFLoginEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains one entry for each Nx_Port logged-
in/attached to a particular Fx_Port in the switch. Each
entry contains the services parameters established during
the most recent Fabric Login, explicit or implicit. Note
that an Fx_Port may have one or more Nx_Ports attached to
it."
::= { fcmgmtObjects 9 }
fcmFLoginEntry OBJECT-TYPE
SYNTAX FcmFLoginEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing service parameters established from a
successful Fabric Login."
INDEX { ifIndex, fcmFLoginNxPortIndex }
::= { fcmFLoginTable 1 }
FcmFLoginEntry ::=
SEQUENCE {
fcmFLoginNxPortIndex Unsigned32,
fcmFLoginPortWwn FcNameIdOrZero,
fcmFLoginNodeWwn FcNameIdOrZero,
fcmFLoginBbCreditModel FcBbCreditModel,
fcmFLoginBbCredit FcBbCredit,
Expires June 2005 [Page 49]
Internet Draft Fibre Channel Management MIB December 2004
fcmFLoginClassesAgreed FcClasses,
fcmFLoginClass2SeqDelivAgreed TruthValue,
fcmFLoginClass2DataFieldSize FcDataFieldSize,
fcmFLoginClass3SeqDelivAgreed TruthValue,
fcmFLoginClass3DataFieldSize FcDataFieldSize
}
fcmFLoginNxPortIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer which uniquely identifies an Nx_Port
amongst all those attached to the Fx_Port indicated by
ifIndex.
After a value of this object is assigned to a particular
Nx_Port, that value can be re-used when and only when it is
assigned to the same Nx_Port, or, after a reset of the value
of the relevant instance of ifCounterDiscontinuityTime."
REFERENCE "The Interfaces Group MIB, RFC 2863, June 2000."
::= { fcmFLoginEntry 1 }
fcmFLoginPortWwn OBJECT-TYPE
SYNTAX FcNameIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port name of the attached Nx_Port, or the zero-length
string if unknown."
::= { fcmFLoginEntry 2 }
fcmFLoginNodeWwn OBJECT-TYPE
SYNTAX FcNameIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node name of the attached Nx_Port, or the zero-length
string if unknown."
::= { fcmFLoginEntry 3 }
fcmFLoginBbCreditModel OBJECT-TYPE
SYNTAX FcBbCreditModel
MAX-ACCESS read-only
STATUS current
Expires June 2005 [Page 50]
Internet Draft Fibre Channel Management MIB December 2004
DESCRIPTION
"The buffer-to-buffer credit model in use by the Fx_Port."
::= { fcmFLoginEntry 4 }
fcmFLoginBbCredit OBJECT-TYPE
SYNTAX FcBbCredit
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of buffers available for holding frames to be
transmitted to the attached Nx_Port. These buffers are for
buffer-to-buffer flow control in the direction from Fx_Port
to Nx_Port."
::= { fcmFLoginEntry 5 }
fcmFLoginClassesAgreed OBJECT-TYPE
SYNTAX FcClasses
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Classes of Service which the Fx_Port has agreed to
support for this Nx_Port."
::= { fcmFLoginEntry 6 }
fcmFLoginClass2SeqDelivAgreed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of whether the Fx_Port has agreed to support
Class 2 sequential delivery for this Nx_Port. This is only
meaningful if Class 2 service has been agreed."
::= { fcmFLoginEntry 7 }
fcmFLoginClass2DataFieldSize OBJECT-TYPE
SYNTAX FcDataFieldSize
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Receive Data Field Size which the Fx_Port has agreed to
support for Class 2 frames to/from this Nx_Port. The size
specifies the largest Data Field Size for an FT_1 frame.
This is only meaningful if Class 2 service has been agreed."
::= { fcmFLoginEntry 8 }
Expires June 2005 [Page 51]
Internet Draft Fibre Channel Management MIB December 2004
fcmFLoginClass3SeqDelivAgreed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of whether the Fx_Port has agreed to support
Class 3 sequential delivery for this Nx_Port. This is only
meaningful if Class 3 service has been agreed."
::= { fcmFLoginEntry 9 }
fcmFLoginClass3DataFieldSize OBJECT-TYPE
SYNTAX FcDataFieldSize
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Receive Data Field Size which the Fx_Port has agreed to
support for Class 3 frames to/from this Nx_Port. The size
specifies the largest Data Field Size for an FT_1 frame.
This is only meaningful if Class 3 service has been agreed."
::= { fcmFLoginEntry 10 }
--********************************
-- The Link table
--
-- This table is intended to assist management applications
-- in determining the topology of the network. The table
-- contains any recent information which the agent knows
-- about Fibre Channel links, both those which terminate at
-- a local port, as well as any others for which information
-- is known.
fcmLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF FcmLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing any Fibre Channel link information which
is known to local Fibre Channel managed instances. One end
of such a link is typically at a local port, but the table
can also contain information on links for which neither end
is a local port.
If one end of a link terminates locally, then that end is
termed 'end1'; the other end is termed 'end2'."
Expires June 2005 [Page 52]
Internet Draft Fibre Channel Management MIB December 2004
::= { fcmgmtObjects 10 }
fcmLinkEntry OBJECT-TYPE
SYNTAX FcmLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing information which a particular Fibre
Channel managed instance has about a Fibre Channel link.
The two ends of the link are called 'end1' and 'end2'."
INDEX { fcmInstanceIndex, fcmLinkIndex }
::= { fcmLinkTable 1 }
FcmLinkEntry ::=
SEQUENCE {
fcmLinkIndex Unsigned32,
fcmLinkEnd1NodeWwn FcNameIdOrZero,
fcmLinkEnd1PhysPortNumber Unsigned32,
fcmLinkEnd1PortWwn FcNameIdOrZero,
fcmLinkEnd2NodeWwn FcNameIdOrZero,
fcmLinkEnd2PhysPortNumber Unsigned32,
fcmLinkEnd2PortWwn FcNameIdOrZero,
fcmLinkEnd2AgentAddress SnmpAdminString,
fcmLinkEnd2PortType FcPortType,
fcmLinkEnd2UnitType FcUnitFunctions,
fcmLinkEnd2FcAddressId FcAddressIdOrZero
}
fcmLinkIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer which uniquely identifies one link
within the set of links about which a particular managed
instance has information."
::= { fcmLinkEntry 1 }
fcmLinkEnd1NodeWwn OBJECT-TYPE
SYNTAX FcNameIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node name of end1, or the zero-length string if
Expires June 2005 [Page 53]
Internet Draft Fibre Channel Management MIB December 2004
unknown."
::= { fcmLinkEntry 2 }
fcmLinkEnd1PhysPortNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The physical port number of end1, or zero if unknown."
REFERENCE
"FC-GS-3, section 6.1.2.2.5"
::= { fcmLinkEntry 3 }
fcmLinkEnd1PortWwn OBJECT-TYPE
SYNTAX FcNameIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port WWN of end1, or the zero-length string if unknown.
('end1' is local if this value is equal to the value of
fcmPortWwn in one of the rows of the fcmPortTable.)"
::= { fcmLinkEntry 4 }
fcmLinkEnd2NodeWwn OBJECT-TYPE
SYNTAX FcNameIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The node name of end2, or the zero-length string if
unknown."
::= { fcmLinkEntry 5 }
fcmLinkEnd2PhysPortNumber OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The physical port number of end2, or zero if unknown."
REFERENCE
"FC-GS-3, section 6.1.2.2.5"
::= { fcmLinkEntry 6 }
fcmLinkEnd2PortWwn OBJECT-TYPE
SYNTAX FcNameIdOrZero
MAX-ACCESS read-only
Expires June 2005 [Page 54]
Internet Draft Fibre Channel Management MIB December 2004
STATUS current
DESCRIPTION
"The port WWN of end2, or the zero-length string if
unknown."
::= { fcmLinkEntry 7 }
fcmLinkEnd2AgentAddress OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The address of the management agent for the Fibre Channel
Interconnect Element or Platform of which end2 is a part.
The GS-4 specification provides some information about
management agents. If the address is unknown, the value of
this object is the zero-length string."
REFERENCE
"FC-GS-3, section 6.1.2.1.7"
::= { fcmLinkEntry 8 }
fcmLinkEnd2PortType OBJECT-TYPE
SYNTAX FcPortType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port type of end2."
REFERENCE
"FC-GS-3, section 6.1.2.2.2"
::= { fcmLinkEntry 9 }
fcmLinkEnd2UnitType OBJECT-TYPE
SYNTAX FcUnitFunctions
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of/function(s) performed by the Fibre Channel
Interconnect Element or Platform of which end2 is a part."
REFERENCE
"FC-GS-3, sections 6.1.2.1.2 and 6.1.2.3.2"
::= { fcmLinkEntry 10 }
fcmLinkEnd2FcAddressId OBJECT-TYPE
SYNTAX FcAddressIdOrZero
MAX-ACCESS read-only
STATUS current
Expires June 2005 [Page 55]
Internet Draft Fibre Channel Management MIB December 2004
DESCRIPTION
"The Fibre Channel Address ID of end2, or the zero-length
string if unknown."
::= { fcmLinkEntry 11 }
Expires June 2005 [Page 56]
Internet Draft Fibre Channel Management MIB December 2004
--********************************
-- Conformance Section
--
fcmgmtCompliances OBJECT IDENTIFIER ::= { fcmgmtConformance 1 }
fcmgmtGroups OBJECT IDENTIFIER ::= { fcmgmtConformance 2 }
fcmgmtCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for compliance to this Fibre
Channel Management MIB."
MODULE -- this module
MANDATORY-GROUPS { fcmInstanceBasicGroup,
fcmPortBasicGroup,
fcmPortErrorsGroup }
GROUP fcmPortStatsGroup
DESCRIPTION
"This group is mandatory for all systems which
are able to support the Counter64 date type."
GROUP fcmPortClass23StatsGroup
DESCRIPTION
"This group is mandatory only for systems which
keep class-specific traffic statistics on Class 2
on Class 3 traffic and are able to support the
Counter64 date type."
GROUP fcmPortClassFStatsGroup
DESCRIPTION
"This group is mandatory only for FC switches which
keep statistics on Class F traffic."
GROUP fcmPortLcStatsGroup
DESCRIPTION
"This group is mandatory only for agents which can not
support the Counter64 data type and/or need to provide
information accessible by SNMPv1 applications."
GROUP fcmSwitchBasicGroup
DESCRIPTION
"This group is mandatory only for Fibre Channel
managed instances which manage Fibre Channel
switches."
Expires June 2005 [Page 57]
Internet Draft Fibre Channel Management MIB December 2004
GROUP fcmSwitchPortGroup
DESCRIPTION
"This group is mandatory only for Fibre Channel
managed instances which manage Fibre Channel
switches."
GROUP fcmSwitchLoginGroup
DESCRIPTION
"This group is mandatory only for Fibre Channel
managed instances which manage Fibre Channel
switches."
GROUP fcmLinkBasicGroup
DESCRIPTION
"This group is optional."
OBJECT fcmInstancePhysicalIndex
SYNTAX Integer32 (0)
DESCRIPTION
"Implementation of a non-zero value is not required."
OBJECT fcmInstanceSoftwareIndex
SYNTAX Integer32 (0)
DESCRIPTION
"Implementation of a non-zero value is not required."
OBJECT fcmInstanceTextName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT fcmInstanceDescr
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT fcmPortAdminType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT fcmPortAdminSpeed
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
Expires June 2005 [Page 58]
Internet Draft Fibre Channel Management MIB December 2004
OBJECT fcmSwitchDomainId
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT fcmISPortClassFCredit
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { fcmgmtCompliances 1 }
--********************************
-- Object Groups
--
fcmInstanceBasicGroup OBJECT-GROUP
OBJECTS { fcmInstanceWwn, fcmInstanceFunctions,
fcmInstancePhysicalIndex, fcmInstanceSoftwareIndex,
fcmInstanceStatus, fcmInstanceTextName,
fcmInstanceDescr, fcmInstanceFabricId }
STATUS current
DESCRIPTION
"Basic information about Fibre Channel managed instances."
::= { fcmgmtGroups 1 }
fcmSwitchBasicGroup OBJECT-GROUP
OBJECTS { fcmSwitchDomainId, fcmSwitchPrincipal, fcmSwitchWWN }
STATUS current
DESCRIPTION
"Basic information about Fibre Channel switches."
::= { fcmgmtGroups 2 }
fcmPortBasicGroup OBJECT-GROUP
OBJECTS { fcmPortInstanceIndex, fcmPortWwn, fcmPortNodeWwn,
fcmPortAdminType, fcmPortOperType, fcmPortFcCapClass,
fcmPortFcOperClass, fcmPortTransmitterType,
fcmPortConnectorType, fcmPortSerialNumber,
fcmPortPhysicalNumber, fcmPortAdminSpeed,
fcmPortCapProtocols, fcmPortOperProtocols }
STATUS current
DESCRIPTION
"Basic information about Fibre Channel ports."
Expires June 2005 [Page 59]
Internet Draft Fibre Channel Management MIB December 2004
::= { fcmgmtGroups 3 }
fcmPortStatsGroup OBJECT-GROUP
OBJECTS { fcmPortBBCreditZeros, fcmPortFullInputBuffers }
STATUS current
DESCRIPTION
"Traffic statistics, which are not specific to any one class
of service, for Fibre Channel ports."
::= { fcmgmtGroups 4 }
fcmPortClass23StatsGroup OBJECT-GROUP
OBJECTS { fcmPortClass2RxFrames, fcmPortClass2RxOctets,
fcmPortClass2TxFrames, fcmPortClass2TxOctets,
fcmPortClass2Discards, fcmPortClass2RxFbsyFrames,
fcmPortClass2RxPbsyFrames,
fcmPortClass2RxFrjtFrames,
fcmPortClass2RxPrjtFrames,
fcmPortClass2TxFbsyFrames,
fcmPortClass2TxPbsyFrames,
fcmPortClass2TxFrjtFrames,
fcmPortClass2TxPrjtFrames, fcmPortClass3RxFrames,
fcmPortClass3RxOctets, fcmPortClass3TxFrames,
fcmPortClass3TxOctets, fcmPortClass3Discards }
STATUS current
DESCRIPTION
"Traffic statistics for Class 2 and Class 3 traffic on Fibre
Channel ports."
::= { fcmgmtGroups 5 }
fcmPortClassFStatsGroup OBJECT-GROUP
OBJECTS { fcmPortClassFRxFrames,
fcmPortClassFRxOctets,
fcmPortClassFTxFrames,
fcmPortClassFTxOctets,
fcmPortClassFDiscards }
STATUS current
DESCRIPTION
"Traffic statistics for Class F traffic on Fibre Channel
ports."
::= { fcmgmtGroups 6 }
fcmPortLcStatsGroup OBJECT-GROUP
OBJECTS { fcmPortLcBBCreditZeros, fcmPortLcFullInputBuffers,
fcmPortLcClass2RxFrames, fcmPortLcClass2RxOctets,
fcmPortLcClass2TxFrames, fcmPortLcClass2TxOctets,
Expires June 2005 [Page 60]
Internet Draft Fibre Channel Management MIB December 2004
fcmPortLcClass2Discards, fcmPortLcClass3Discards,
fcmPortLcClass3RxFrames, fcmPortLcClass3RxOctets,
fcmPortLcClass3TxFrames, fcmPortLcClass3TxOctets,
fcmPortLcClass2RxFbsyFrames,
fcmPortLcClass2RxPbsyFrames,
fcmPortLcClass2RxFrjtFrames,
fcmPortLcClass2RxPrjtFrames,
fcmPortLcClass2TxFbsyFrames,
fcmPortLcClass2TxPbsyFrames,
fcmPortLcClass2TxFrjtFrames,
fcmPortLcClass2TxPrjtFrames }
STATUS current
DESCRIPTION
"Low-capacity (32-bit) statistics for Fibre Channel ports."
::= { fcmgmtGroups 7 }
fcmPortErrorsGroup OBJECT-GROUP
OBJECTS { fcmPortRxLinkResets, fcmPortTxLinkResets,
fcmPortLinkResets, fcmPortRxOfflineSequences,
fcmPortTxOfflineSequences, fcmPortLinkFailures,
fcmPortLossofSynchs, fcmPortLossofSignals,
fcmPortPrimSeqProtocolErrors, fcmPortInvalidTxWords,
fcmPortInvalidCRCs, fcmPortInvalidOrderedSets,
fcmPortFrameTooLongs, fcmPortTruncatedFrames,
fcmPortAddressErrors, fcmPortDelimiterErrors,
fcmPortEncodingDisparityErrors,
fcmPortOtherErrors }
STATUS current
DESCRIPTION
"Error statistics for Fibre Channel ports."
::= { fcmgmtGroups 8 }
fcmSwitchPortGroup OBJECT-GROUP
OBJECTS { fcmFxPortRatov, fcmFxPortEdtov, fcmFxPortRttov,
fcmFxPortHoldTime, fcmFxPortCapBbCreditMax,
fcmFxPortCapBbCreditMin,
fcmFxPortCapDataFieldSizeMax,
fcmFxPortCapDataFieldSizeMin,
fcmFxPortCapClass2SeqDeliv,
fcmFxPortCapClass3SeqDeliv,
fcmFxPortCapHoldTimeMax,
fcmFxPortCapHoldTimeMin,
fcmISPortClassFCredit,
fcmISPortClassFDataFieldSize }
STATUS current
Expires June 2005 [Page 61]
Internet Draft Fibre Channel Management MIB December 2004
DESCRIPTION
"Information about ports on a Fibre Channel switch."
::= { fcmgmtGroups 9 }
fcmSwitchLoginGroup OBJECT-GROUP
OBJECTS { fcmFLoginPortWwn, fcmFLoginNodeWwn,
fcmFLoginBbCreditModel, fcmFLoginBbCredit,
fcmFLoginClassesAgreed,
fcmFLoginClass2SeqDelivAgreed,
fcmFLoginClass2DataFieldSize,
fcmFLoginClass3SeqDelivAgreed,
fcmFLoginClass3DataFieldSize }
STATUS current
DESCRIPTION
"Information known to a Fibre Channel switch about
attached/logged-in Nx_Ports."
::= { fcmgmtGroups 10 }
fcmLinkBasicGroup OBJECT-GROUP
OBJECTS { fcmLinkEnd1NodeWwn , fcmLinkEnd1PhysPortNumber,
fcmLinkEnd1PortWwn, fcmLinkEnd2NodeWwn ,
fcmLinkEnd2PhysPortNumber, fcmLinkEnd2PortWwn,
fcmLinkEnd2AgentAddress, fcmLinkEnd2PortType,
fcmLinkEnd2UnitType, fcmLinkEnd2FcAddressId }
STATUS current
DESCRIPTION
"Information about Fibre Channel links."
::= { fcmgmtGroups 11 }
END
Expires June 2005 [Page 62]
Internet Draft Fibre Channel Management MIB December 2004
7. Intellectual Property
The IETF takes no position regarding the validity or scope of any
intellectual property or other rights that might be claimed to pertain
to the implementation or use of the technology described in this
document or the extent to which any license under such rights might or
might not be available; neither does it represent that it has made any
effort to identify any such rights. Information on the IETF's
procedures with respect to rights in standards-track and standards-
related documentation can be found in BCP-11. Copies of claims of
rights made available for publication and any assurances of licenses to
be made available, or the result of an attempt made to obtain a general
license or permission for the use of such proprietary rights by
implementors or users of this specification can be obtained from the
IETF Secretariat.
The IETF invites any interested party to bring to its attention any
copyrights, patents or patent applications, or other proprietary rights
which may cover technology that may be required to practice this
standard. Please address the information to the IETF Executive
Director.
8. Acknowledgements
This memo is partly based on the information contained in the original
submission of the Fibre Channel Management Integration MIB to the IETF's
IPFC Working Group as draft-ietf-ipfc-fcmgmt-int-mib-0n.txt, and partly
based on RFC 2837.
Feedback has been incorporated into this document based on the comments
of the following: Sudhir Pendse, SimpleSoft; Steve Senum, Cisco Systems;
and Kha Sin Teow, Brocade.
9. Normative References
[RFC2434]
Narten, T. and H. Alvestrand, "Guidelines for Writing an IANA
Considerations Section in RFCs", BCP:26, RFC 2434, October 1998.
[RFC2578]
McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, M.
and S. Waldbusser, "Structure of Management Information Version 2
(SMIv2)", STD 58, RFC 2578, April 1999.
Expires June 2005 [Page 63]
Internet Draft Fibre Channel Management MIB December 2004
[RFC2579]
McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, M.
and S. Waldbusser, "Textual Conventions for SMIv2", STD 58, RFC
2579, April 1999.
[RFC2580]
McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, M.
and S. Waldbusser, "Conformance Statements for SMIv2", STD 58, RFC
2580, April 1999.
[RFC2737]
McCloghrie, K., and A. Bierman, "Entity MIB (Version 2)", RFC 2737,
December 1999.
[RFC2790]
Waldbusser, S., and P. Grillo, "Host Resources MIB", RFC 2790,
March 2000.
[RFC2863]
McCloghrie, K., and F. Kastenholz, "The Interfaces Group MIB", RFC
2863, Cisco Systems, Argon Networks, June 2000.
[RFC3411]
Harrington, D., Presuhn, R., and B. Wijnen, "An Architecture for
Describing Simple Network Management Protocol (SNMP) Management
Frameworks", STD 58, RFC 3411, December 2002.
[FC-AL]
"Information Technology - Fibre Channel - Arbitrated Loop (FC-AL)",
ANSI X3.272, 1996.
[FC-AL-2]
"Fibre Channel - Arbitrated Loop (FC-AL-2)", ANSI INCITS 332-1999,
1999.
[FC-BB]
"Fibre Channel - Backbone (FC-BB)" ANSI INCITS 342-2001, 2001.
[FCP]
"SCSI-3 Fibre Channel Protocol (FCP)", ANSI X3.269, 1996.
[FC-FLA]
"Fibre Channel - Fabric Loop Attachment (FC-FLA)", ANSI INCITS
TR-20-1998, 1998.
Expires June 2005 [Page 64]
Internet Draft Fibre Channel Management MIB December 2004
[FC-FS]
"Fibre Channel - Framing and Signaling (FC-FS)" ANSI INCITS
373-2003, April 2003.
[FC-GS-3]
"Fibre Channel - Generic Services - 3 (FC-GS-3)" ANSI INCITS
348-2001, 2001.
[FC-MI]
"Fibre Channel - Methodologies for Interconnects Technical Report
(FC-MI)" INCITS TR-30-2002, 2002.
[FC-PH]
"Information Technology - Fibre Channel Physical and Signaling
Interface (FC-PH)", ANSI X3.230, 1994.
[FC-SW]
"Fibre Channel - Switch Fabric (FC-SW)", ANSI INCITS 321-1998,
1998.
[FC-SW2]
"Fibre Channel - Switch Fabric - 2 (FC-SW-2)", ANSI INCITS
355-2001, June 2001.
10. Informative References
[RFC2741]
Daniele, M., Wijnen, B., Ellison, M., and D. Francisco. "Agent
Extensibility (AgentX) Protocol Version 1", RFC 2741, January 2000.
[RFC2837]
Teow, K., "Definitions of Managed Objects for the Fabric Element in
Fibre Channel Standard", RFC 2837, May 2000.
[RFC3410]
Case, J., Mundy, R., Partain, D. and B. Stewart, "Introduction and
Applicability Statements for Internet-Standard Management
Framework", RFC 3410, December 2002.
[WWN1]
Snively, R., "New identifier formats based on IEEE registration",
http://standards.ieee.org/regauth/oui/tutorials/fibreformat.html,
16 January 2001.
Expires June 2005 [Page 65]
Internet Draft Fibre Channel Management MIB December 2004
[WWN2]
Snively, R., "Use of the IEEE Registration Authority assigned
'company_id' with the ANSI X3.230 FC-PH Fibre Channel specification
and its extensions",
http://standards.ieee.org/regauth/oui/tutorials/fibrecomp_id.html,
24 February 1997.
[SENSOR]
Bierman, A., Romascanu, D., and KC Norseth, "Entity Sensor
Management Information Base", Internet Draft, working draft, 16
October 2002.
11. Security Considerations
There are a number of management objects defined in this MIB that have a
MAX-ACCESS clause of read-write:
fcmInstanceTextName
fcmInstanceDescr
fcmSwitchDomainId
fcmPortAdminType
fcmPortAdminSpeed
fcmISPortClassFCredit
Such objects may be considered sensitive or vulnerable in some network
environments. For example, the ability to change network topology or
network speed may afford an attacker the ability to obtain better
performance at the expense of other network users; setting
fcmSwitchDomainId to an invalid value could lead to denial of service in
some configurations. The support for SET operations in a non-secure
environment without proper protection can have a negative effect on
network operations.
Some of the readable objects in this MIB module (i.e., objects with a
MAX-ACCESS other than not-accessible) may be considered sensitive or
vulnerable in some network environments. It is thus important to
control even GET and/or NOTIFY access to these objects and possibly to
even encrypt the values of these objects when sending them over the
network via SNMP. In particular, these objects provide information on
network topology:
fcmLinkEnd1NodeWwn
fcmLinkEnd1PhysPortNumber
fcmLinkEnd1PortWwn
Expires June 2005 [Page 66]
Internet Draft Fibre Channel Management MIB December 2004
fcmLinkEnd2NodeWwn
fcmLinkEnd2PhysPortNumber
fcmLinkEnd2PortWwn
fcmLinkEnd2AgentAddress
fcmLinkEnd2PortType
fcmLinkEnd2UnitType
fcmLinkEnd2FcAddressId
SNMP versions prior to SNMPv3 did not include adequate security. Even
if the network itself is secure (for example by using IPSec), even then,
there is no control as to who on the secure network is allowed to access
and GET/SET (read/change/create/delete) the objects in this MIB module.
It is RECOMMENDED that implementors consider the security features as
provided by the SNMPv3 framework (see [RFC3410], section 8), including
full support for the SNMPv3 cryptographic mechanisms (for authentication
and privacy).
Further, deployment of SNMP versions prior to SNMPv3 is NOT RECOMMENDED.
Instead, it is RECOMMENDED to deploy SNMPv3 and to enable cryptographic
security. It is then a customer/operator responsibility to ensure that
the SNMP entity giving access to an instance of this MIB module is
properly configured to give access to the objects only to those
principals (users) that have legitimate rights to indeed GET or SET
(change/create/delete) them.
12. IANA Considerations
12.1. OID Assignment
IANA is requested to make a MIB OID assignment under the transmission
branch. Specifically, for { transmission 56 } to be assigned as the OID
for fcMgmtMIB. This sub-identifier is requested because this MIB
contains the media-specific definitions which correspond to the ifType
value of fibreChannel(56).
12.2. FC Port Type Registry
IANA is requested to establish a registry for Fibre Channel Port Types.
The registry is to be split into disjoint subset ranges:
1) a 'standard' range for Fibre Channel Port Types which have been
standardized by the InterNational Committee for Information
Technology Standards (INCITS)'s Technical Committee T11 (see
Expires June 2005 [Page 67]
Internet Draft Fibre Channel Management MIB December 2004
http://www.incits.org/tc_home/t11.htm and
http://www.t11.org/index.htm). This range will be subject to the
'Expert Review' and 'Specification Required' policies described in
[RFC2434], with the following provisions:
- the Expert Reviewer is to be appointed by the IESG.
- the Expert Reviewer shall obtain approval (or rejection) from
INCITS Technical Committee T11 via the chair of that Committee.
Rejected values shall not be added to the registry.
- if the addition is approved, the Expert shall advise IANA of how
to record the reference to the T11 specification document which
describes the newly added port type(s), and which is considered
to be the "other permanent and readily available reference"
required by [RFC2434].
The initial assignments in the 'standard' range will be as follows:
Assigned
Value Type Meaning
-------- ------ -------
1 unknown for use when the type is not known,
or is "unidentified" as specified in
section 5.1.2.10 of [FC-GS-3]
2 other used for types without assigned values
3 -- an obsolete value, not to be re-assigned
4 N_Port see [FC-FS]
5 NL_Port see [FC-FS]
6 F_Port see [FC-FS]
7 FL_Port see [FC-FS]
8 E_Port see [FC-FS]
9 B_Port see [FC-FS]
10 G_Port see [FC-SW-3]
11 GL_Port see [FC-SW-3]
12 F/NL_Port see [FC-AL-2]
It is suggested that the above range can be extended up to a maximum
of 9,999.
2) a range which is assigned under the "Private Use" policy described in
[RFC2434] and is for values intended for private use by one party or
among mutually consenting parties. It is suggested that values in
this range extend from 10,000 to 99,999. IANA is instructed not to
make any allocations from this range.
Expires June 2005 [Page 68]
Internet Draft Fibre Channel Management MIB December 2004
3) values larger than 99,999 be RESERVED.
Expires June 2005 [Page 69]
Internet Draft Fibre Channel Management MIB December 2004
13. Comparison to draft-ietf-ipfc-fcmgmt-int-mib-07.txt
13.1. Problems with draft-ietf-ipfc-fcmgmt-int-mib-07.txt
The Fibre Channel Management Integration MIB had the following major
problems:
- It wasn't formatted using SMIv2, which is mandatory.
- The MIB seemed to have been defined with the notion that it would
be the only MIB that a Fibre Channel product will require. The
notion of an agent implementing just a single MIB was abandoned by
the IETF in 1992 as being non-scaleable. Rather, a Fibre Channel
MIB needed to be another MIB in the continuing series of MIBs
defined by the IETF, and thus, it needed to be consistent with its
predecessors. In other words, there are existing MIBs which all
SNMP agents must support, even if the support of Fibre Channel
interfaces is the only functionality that they have. Thus, it was
essential that the Fibre Channel Integration MIB contained only
objects for information which is specific to Fibre Channel. All
objects relevant to non-Fibre Channel environments needed to be
removed. This issue applied to a large fraction of the objects
defined in the MIB.
- The MIB had some but not complete overlap in functionality with RFC
2837.
- Every SNMP agent must implement the ifTable. The ifTable counters
are the MIB objects most well-used by administrators in SNMP
management. SNMP agents need to implement a row in the ifTable for
each of their network interfaces, including their Fibre Channel
interfaces. The IF-MIB requires a media-specific MIB to specify
how that type of interface uses the ifTable (see section 4 in RFC
2863). RFC 2837 doesn't do that, and nor did the Fibre Channel
Integration MIB.
- It incorrectly used the OCTET STRING syntax (instead of Counter32
or Counter64) for counters.
Expires June 2005 [Page 70]
Internet Draft Fibre Channel Management MIB December 2004
13.2. Detailed Changes
13.2.1. Removal of Sensor-related objects
Information about sensors is not specific to Fibre Channel, and
therefore should not be in this MIB. (At the time of writing, the the
IETF's ENTITY MIB Working Group has produced a first draft of a Sensor
MIB, see [SENSOR].) This removed the need for:
connUnitSensorTable (and all its contents)
connUnitNumSensors
connUnitSensorStatusChange
13.2.2. Removal of Trap-registration objects
Information about registering "traps" is not specific to Fibre Channel,
and therefore should not be in this MIB. (For similar functionality,
see SNMP-NOTIFICATION-MIB and SNMP-TARGET-MIB in RFC 2573). This
removed the need for:
trapMaxClients
trapClientCount
trapRegTable (and all its contents)
13.2.3. Removal of Event-related objects
Information about generic events is not specific to Fibre Channel, and
therefore should not be in this MIB. (For similar functionality, see
the Event group in RFC 2819 and the Notification Log MIB in RFC 3014;
the SNMP-NOTIFICATION-MIB provides for the filtering of notifications.)
This removed the need for:
connUnitEventTable (and all its contents)
connUnitEventFilter
connUnitNumEvents
connUnitMaxEvents
connUnitEventCurrID
connUnitEventTrap
Expires June 2005 [Page 71]
Internet Draft Fibre Channel Management MIB December 2004
13.2.4. Removal of inventory-related information
Aspects of hardware (physical) components are represented in the Entity
MIB (RFC 2737); aspects of software modules are represented in the Host
Resources MIB (RFC 2790). Two new objects provide indexing from this
MIB into those MIBs: one having the value of PhysicalIndex (or zero) and
the other having the value of hrSWInstalledIndex (or zero). These
replaced the need for:
connUnitNumports
connUnitRevsTable (and all its contents)
connUnitNumRevs
connUnitPortRevision
connUnitPortVendor
connUnitProduct
connUnitInfo
connUnitSn
connUnitModuleId
connUnitVendorId
connUnitDeletedTrap
13.2.5. Removal of revision numbers
The forward/backward compatibility rules of how to evolve MIBs are
designed such that MIBs do not have revision numbers. This removed the
need for:
revisionNumber
13.2.6. Removal of other not FC-specific information
Other information was removed because it was not specific to Fibre
Channel:
systemURL
statusChangeTime
configurationChangeTime
connUnitUrl
connUnitUpTime
connUnitState
connUnitContact
connUnitLocation
connUnitProxyMaster
connUnitControl
connUnitStatus
Expires June 2005 [Page 72]
Internet Draft Fibre Channel Management MIB December 2004
connUnitStatusChange
13.2.7. Clean-up of ambiguous/obsolete definitions
Some information in the FC Management integration was obsolete or
ambiguous:
statusChangeTime (obsolete)
configurationChangeTime (obsolete)
connUnitTableChangeTime (obsolete)
connUnitStatusChangeTime (obsolete)
connUnitConfigurationChangeTime (obsolete)
connUnitNumZones (obsolete)
connUnitZoneTable (referenced but not defined)
connUnitLinkCurrIndex (badly defined)
13.2.8. Use of an ifTable entry
The following objects were removed because they duplicated existing IF-
MIB objects:
redundant object existing object(s)
---------------- ------------------
connUnitPortStatCountError ifInErrors & ifOutErrors
connUnitPortStatCountTxObjects ifOutUcastPkts &
ifHCOutUcastPkts
connUnitPortStatCountRxObjects ifInUcastPkts &
ifHCInUcastPkts
connUnitPortStatCountTxElements ifOutOctets &
ifHCOutOctets
connUnitPortStatCountRxElements ifInOctets &
ifHCInOctets
connUnitPortStatCountRxMulticastObjects
ifInMulticastPkts &
ifHCInMulticastPkts
connUnitPortStatCountTxMulticastObjects
ifOutMulticastPkts &
ifHCOutMulticastPkts
connUnitPortStatCountRxBroadcastObjects
ifInBroadcastPkts &
ifHCInBroadcastPkts
connUnitPortStatCountTxBroadcastObjects
ifOutBroadcastPkts &
ifHCOutBroadcastPkts
connUnitPortFCId ifPhysAddress
Expires June 2005 [Page 73]
Internet Draft Fibre Channel Management MIB December 2004
connUnitPortControl ifAdminStatus
connUnitPortState ifAdminStatus
connUnitPortHWState ifOperStatus
connUnitPortStatus ifOperStatus
connUnitPortName ifAlias
connUnitPortStatObject ifSpecific
connUnitNumports ifNumber
connUnitPortStatusChange linkUp/linkDown
13.2.9. Removed because of AgentX difficulty
An AgentX environment [RFC2741] consists of a master agent and several
sub-agents. It is not difficult to implement the same MIB in several
such sub-agents if all of the MIB's tables have a common index variable
as the first auxiliary object in their INDEX clauses. However, any
scalars which the MIB contains pose a problem for the AgentX
environment. All the (remaining) scalars were therefore removed:
revisionNumber
uNumber
systemURL
13.2.10. FC Management Instance
The term "connectivity unit" was changed to "FC management instance".
The term "connectivity unit" was not properly defined in draft-ietf-
ipfc-fcmgmt-int-mib-07.txt, and its usage provided a confused mixture of
indications to the implementor:
- the definition of FcUnitType suggested it was functional;
- the definition of uNumber suggested it was physical;
- the definition of connUnitProduct suggested it was a vendor's product;
- etc.
The common implementation strategy for "connectivity unit" was whatever
grouping was easiest in providing access to the management
functionality. (One such grouping accommodates a single SNMP agent
having multiple AgentX [RFC2741] sub-agents, each supporting a separate
implementation of the MIB.)
In fact, this scenario is not new; in practice, a "connectivity unit"
will have the same semantics as a management "instance" in other MIBs,
e.g., the IPS WG's own iSCSI MIB. For this MIB, its meaning is: "a
separable managed instance of Fibre Channel functionality". Given this
Expires June 2005 [Page 74]
Internet Draft Fibre Channel Management MIB December 2004
definition, then "FC management instance" is a better name because it is
more accurate and more representative of the definition, than is
"connectivity unit".
13.2.11. Counter Syntax
All packet and octet counters have been changed to be Counter64's (but
Counter32 versions of them are also included for use by old agents).
The error counters have been changed to Counter32's. (In the probably
impossible, and at most improbable, circumstances that the rate of
occurrence of errors, even on a 10Gbs Fibre Channel interface, might
wrap faster than a hour, the fact that errors are occurring will almost
certainly be apparent from other MIB objects.)
13.2.12. Obsolete/Little-Used Fibre Channel features
Information relating to Fibre Channel features which are obsolete or not
widely-implemented has been deleted. (For more information, see section
6.2.1 and section 6.2.2 of [FC-MI].)
- Class 1 service,
- Intermix Mode,
- Stacked Conn Mode.
- PH version numbers
Note that with support for Class 1 service being deleted, only class 2
now needs F_BSY, F_RJT, P_BSY and P_RJT counters, and thus they no
longer need to be counted for all classes as well as for class 2, and
therefore these objects:
connUnitPortStatCountFBSYFrames
connUnitPortStatCountPBSYFrames
connUnitPortStatCountFRJTFrames
connUnitPortStatCountPRJTFrames
have been deleted.
13.3. Name Server objects
A table of Name Server information was present in draft-ietf-ipfc-
fcmgmt-int-mib-07.txt. That information is not currently represented in
this MIB, because this MIB is already quite large, and a set of Name
Server objects are expected to be defined in a separate (new) MIB.
Expires June 2005 [Page 75]
Internet Draft Fibre Channel Management MIB December 2004
13.4. Additional objects
Support for Class F traffic, including 32-bit octet and frame counters,
has been added.
Expires June 2005 [Page 76]
Internet Draft Fibre Channel Management MIB December 2004
14. Comparison to RFC 2837
This MIB is a superset of RFC 2837, except for the following:
- the fcFeClass1AccountingGroup group is obsolete,
- fcFxPortConnectedNxPort, fcFxPortFcphVersionHigh,
fcFxPortFcphVersionLow, fcFxPortFcphVersionAgreed,
fcFxPortStackedConnModeAgreed, fcFxPortIntermixSuppAgreed,
fcFxPortCapStackedConnMode and fcFxPortCapIntermix are obsolete,
- fcFxPortBbCredit and fcFxPortRxBufSize are per attached Nx_Port,
- fcFxPortBbCreditAvailable is ephemeral,
- fcFeModuleTable is mostly contained in the entPhysicalTable,
- fcFxPortPhysAdminStatus, fcFxPortPhysOperStatus, and
fcFxPortPhysLastChange have equivalents in the ifTable.
Expires June 2005 [Page 77]
Internet Draft Fibre Channel Management MIB December 2004
15. Author's Address
Keith McCloghrie
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA USA 95134
Phone: +1 408-526-5260
Email: kzm@cisco.com
16. Full Copyright Statement
Copyright (C) The Internet Society (2004). All Rights Reserved.
This document and translations of it may be copied and furnished to
others, and derivative works that comment on or otherwise explain it or
assist in its implementation may be prepared, copied, published and
distributed, in whole or in part, without restriction of any kind,
provided that the above copyright notice and this paragraph are included
on all such copies and derivative works. However, this document itself
may not be modified in any way, such as by removing the copyright notice
or references to the Internet Society or other Internet organizations,
except as needed for the purpose of developing Internet standards in
which case the procedures for copyrights defined in the Internet
Standards process must be followed, or as required to translate it into
languages other than English.
The limited permissions granted above are perpetual and will not be
revoked by the Internet Society or its successors or assigns.
This document and the information contained herein is provided on an "AS
IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING TASK
FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT
INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
"Copyright (C) The Internet Society (2004). This document is subject to
the rights, licenses and restrictions contained in BCP 78, and except as
set forth therein, the authors retain all their rights."
"This document and the information contained herein are provided on an
"AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS OR
IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET
Expires June 2005 [Page 78]
Internet Draft Fibre Channel Management MIB December 2004
ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE
INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE."
Expires June 2005 [Page 79]