Networking Working Group Z. Liu
Internet-Draft China Telecom
Intended status: Standards Track L. Jin
Expires: October 26, 2014
R. Chen
ZTE Corporation
D. Cai
S. Salam
Cisco
April 24, 2014
Redundancy Mechanism for Inter-domain VPLS Service
draft-ietf-l2vpn-vpls-inter-domain-redundancy-06
Abstract
In many existing Virtual Private LAN Service (VPLS) inter-domain
deployments (based on RFC 4762), pseudowire (PW) connectivity offers
no node redundancy, or offers node redundancy only with a single
domain. This deployment approach incurs a high risk of service
interruption, since at least one domain will not offer PW node
redundancy. This document describes an inter-domain VPLS solution
that provides PW node redundancy across domains.
Status of this Memo
This Internet-Draft is submitted in full conformance with the
provisions of BCP 78 and BCP 79.
Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF). Note that other groups may also distribute
working documents as Internet-Drafts. The list of current Internet-
Drafts is at http://datatracker.ietf.org/drafts/current/.
Internet-Drafts are draft documents valid for a maximum of six months
and may be updated, replaced, or obsoleted by other documents at any
time. It is inappropriate to use Internet-Drafts as reference
material or to cite them other than as "work in progress."
This Internet-Draft will expire on October 26, 2014.
Copyright Notice
Copyright (c) 2014 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Liu, et al. Expires October 26, 2014 [Page 1]
Internet-Draft Redundancy for VPLS Inter-domain April 2014
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
the Trust Legal Provisions and are provided without warranty as
described in the Simplified BSD License.
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. Conventions used in this document . . . . . . . . . . . . . . 3
3. Motivation . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4. Network Use Case . . . . . . . . . . . . . . . . . . . . . . . 4
5. PW redundancy application procedure for inter-domain
redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.1. ICCP switchover condition . . . . . . . . . . . . . . . . 6
5.1.1. Inter-domain PW failure . . . . . . . . . . . . . . . 6
5.1.2. PE node isolation . . . . . . . . . . . . . . . . . . 6
5.1.3. PE node failure . . . . . . . . . . . . . . . . . . . 6
5.2. Inter-domain redundancy with two-PWs . . . . . . . . . . . 6
5.3. Inter-domain redundancy with four-PWs . . . . . . . . . . 7
6. Management Considerations . . . . . . . . . . . . . . . . . . 9
7. Security Considerations . . . . . . . . . . . . . . . . . . . 9
8. IANA Consideration . . . . . . . . . . . . . . . . . . . . . . 9
9. Acknowledgements . . . . . . . . . . . . . . . . . . . . . . . 9
10. Contributors . . . . . . . . . . . . . . . . . . . . . . . . . 10
11. References . . . . . . . . . . . . . . . . . . . . . . . . . . 10
11.1. Normative references . . . . . . . . . . . . . . . . . . . 10
11.2. Informative references . . . . . . . . . . . . . . . . . . 10
Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . . . 11
Liu, et al. Expires October 26, 2014 [Page 2]
Internet-Draft Redundancy for VPLS Inter-domain April 2014
1. Introduction
In many existing Virtual Private LAN Service (VPLS) deployments based
on [RFC4762], pseudowire (PW) connectivity offers no node redundancy,
or offers node redundancy only with a single domain. This deployment
approach incurs a high risk of service interruption, since at least
one domain will not offer PW node redundancy. This document
describes an inter-domain VPLS solution that provides PW node
redundancy across domains. The redundancy mechanism will provide
node redundancy and link redundancy in both domains. The domain in
this document refers to autonomous system (AS), or other
administrative domains.
The solution relies on the use of Inter-Chassis Communication
Protocol (ICCP) [I-D.ietf-pwe3-iccp] to coordinate between the two
redundant edge nodes, and use of PW Preferential Forwarding Status
Bit [RFC6870] to negotiate the PW status. There is no change to any
protocol message formats and no new protocol options are introduced.
This solution is a description of reusing existing protocol building
blocks to achieve the desired function, but also defines
implementation behavior necessary for the function to work.
2. Conventions used in this document
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in [RFC2119].
3. Motivation
Inter-AS VPLS offerings are widely deployed in service provider
networks today. Typically, the Autonomous System Border Router
(ASBR) and associated physical links that connect the domains carry a
multitude of services. As such, it is important to provide link and
node redundancy, to ensure service high availability and meet the end
customer service level agreements (SLAs).
Several current deployments of inter-AS VPLS are implemented like
inter-AS option A in [RFC4364] section 10, where Virtual Local Area
Network (VLAN) is used to hand-off the services between two domains.
In these deployments, link/node redundancy is achieved using Multi-
Chassis Link Aggregation (MC-LAG) and ICCP [I-D.ietf-pwe3-iccp].
This, however, places two restrictions on the interconnection: the
two domains must be interconnected using Ethernet links, and the
links must be homogeneous, i.e. of the same speed, in order to be
aggregated. These two conditions can not always be guaranteed in
Liu, et al. Expires October 26, 2014 [Page 3]
Internet-Draft Redundancy for VPLS Inter-domain April 2014
live deployments. For instance, there are many scenarios where the
interconnection between the domains uses Packet over Synchronous
Optical Networking (SONET) / Synchronous Digital Hierarchy (SDH),
thereby ruling out the applicability of MC-LAG as a redundancy
mechanism. As such, from a technical point of view, it is desirable
to use PWs to interconnect the VPLS domains, and to offer resiliency
using PW redundancy mechanisms.
Multiprotocol Border Gateway Protocol (MP-BGP) can be used for VPLS
inter-domain protection, as described in [RFC6074], using either
option B or option C inter-AS models. However, with this solution,
the protection time relies on BGP control plane convergence. In
certain deployments, with tight SLA requirements on availability,
this mechanism may not provide the desired failover time
characteristics. Furthermore, in certain situations MP-BGP is not
deployed for VPLS. The redundancy solution described in this
document reuses ICCP [I-D.ietf-pwe3-iccp] and PW redundancy [RFC6718]
to provide fast convergence.
Furthermore, in the case where Label Switched Multicast is not used
for VPLS multicast [RFC7117], the solution described here provides a
better behavior compared to inter-AS option B: with option B, each
Provider Edge (PE) must perform ingress replication to all other PEs
in its local as well as the remote domain. Whereas, with the ICCP
solution, the PE only replicates to local PEs and to the ASBR. The
ASBR then sends traffic point-to-point to the remote ASBR, and the
remote ASBR replicates to its local PEs. As a result, the load of
replication is distributed and is more efficient than option B.
Two PW redundancy modes defined in [RFC6718], namely independent mode
and master/slave mode, are applicable in this solution. In order to
maintain control plane separation between two domains, the
independent mode is preferred by operators. The master/slave mode
provides some enhanced capabilities and, hence, is included in this
document.
4. Network Use Case
There are two network use cases for VPLS inter-domain redundancy:
two-PWs redundancy case, and four-PWs redundancy case.
Figure 1 presents an example use case with two inter-domain PWs.
PE3/PE4/PE5/PE6 may be ASBRs of their respective AS, or VPLS PEs
within its own AS. PE3 and PE4 belong to one redundancy group (RG),
and PE5 and PE6 belong to another RG. A deployment example of this
use case is where there are only two physical links between two
domains and PE3 is physically connected with PE5, and PE4 is
Liu, et al. Expires October 26, 2014 [Page 4]
Internet-Draft Redundancy for VPLS Inter-domain April 2014
physically connected with PE6.
+---------+ +---------+
+---+ | +-----+ | active PW1 | +-----+| +---+
|PE1|---|-| PE3 |-|-----------------|--| PE5 ||----|PE7|
+---+\ |/+-----+ | | +-----+\ /+---+
| \ / | * | | * | |\ / |
| \| | |ICCP| |ICCP| | | \ |
| / \ | * | | * | |/ \ |
+---+/ |\+-----+ | | +-----+/ \+---+
|PE2|---|-| PE4 |-|-----------------|--| PE6 ||----|PE8|
+---+ | +-----+ | standby PW2 | +-----+| +---+
| | | |
| | | |
| RG1 | | RG2 |
+---------+ +---------+
operator A network operator B network
Figure 1
Figure 2 presents a four-PWs inter-domain VPLS redundancy use case.
PE3/PE4/PE5/PE6 may be ASBRs of their respective AS, or VPLS PEs
within its own AS. A deployment example of this use case is where
there are four physical links between two domains and four PEs are
physically connected with each other with four links.
+---------+ +---------+
+---+ | +-----+ | | +-----+| +---+
|PE1|---|-| PE3 |-|--------PW1------|--| PE5 ||----|PE7|
| | | | |-|-PW3\ /------|--| || | |
+---+\ |/+-----+ | \ / | +-----+\ /+---+
| \ / | * | \ / | * | |\ / |
| \| | |ICCP| X |ICCP| | | \ |
| / \ | * | / \ | * | |/ \ |
+---+/ |\+-----+ | / \ | +-----+/ \+---+
| | | | |-|-PW4/ \------|--| || | |
|PE2|---|-| PE4 |-|----PW2----------|--| PE6 ||----|PE8|
+---+ | +-----+ | | +-----+| +---+
| | | |
| | | |
| RG1 | | RG2 |
+---------+ +---------+
operator A network operator B network
Liu, et al. Expires October 26, 2014 [Page 5]
Internet-Draft Redundancy for VPLS Inter-domain April 2014
Figure 2
5. PW redundancy application procedure for inter-domain redundancy
PW redundancy application procedures are described in section 9.1 of
[I-D.ietf-pwe3-iccp]. When a PE node encounters a failure, the other
PE takes over. This document reuses the PW redundancy mechanism
defined in[I-D.ietf-pwe3-iccp], with new ICCP switchover conditions
as specified in following section.
There are two PW redundancy modes defined in [RFC6870]: Independent
mode and Master/Slave mode. For the inter-domain four-PW scenario,
it is required for PEs to ensure that the same mode is supported on
the two ICCP peers in the same RG. This can be achieved using manual
configuration at the ICCP peers. Other methods for ensuring
consistency are out of the scope of this document.
5.1. ICCP switchover condition
5.1.1. Inter-domain PW failure
When a PE receives advertisements from the active PE, in the same RG,
indicating that all the inter-domain PW status has changed to DOWN/
STANDBY, then if it has the highest priority (after the advertising
PE), it SHOULD advertise active state for all of its associated
inter-domain PWs.
5.1.2. PE node isolation
When a PE detects failure of all PWs to the local domain, it SHOULD
advertise standby state for all its inter-domain PWs to trigger
remote PE to switchover.
5.1.3. PE node failure
When a PE node detects that the active PE, that is a member of the
same RG, has gone down, if the local PE has redundant PWs for the
affected services and has the highest priority (after the failed PE),
it SHOULD advertise the active state for all associated inter-domain
PWs.
5.2. Inter-domain redundancy with two-PWs
In this use case, it is recommended that the operation be as follows:
o ICCP deployment option: ICCP is deployed on VPLS edge nodes in
both domains;
Liu, et al. Expires October 26, 2014 [Page 6]
Internet-Draft Redundancy for VPLS Inter-domain April 2014
o PW redundancy mode: independent mode only;
o Protection architectures: 1:1(1 standby, 1 active).
The switchover rules described in section 5.1 apply. Before
deploying this inter-domain VPLS, the operators should negotiate to
configure the same PW high/low priority at two PW end-points. The
inter-domain VPLS relationship normally involves a contractual
process between operators, and the configuration of PW roles forms
part of this process. E.g, in figure 1, PE3 and PE5 must both have
higher/lower priority than PE4 and PE6, otherwise both PW1 and PW2
will be in standby state.
5.3. Inter-domain redundancy with four-PWs
In this use case, there are two options to provide protection: 1:1
and 3:1 protection. The inter-domain PWs that connect to the same PE
should have proper PW priority to advertise same active/standby
state. E.g, in figure 2, both PW1 and PW3 connected to PE3 should
advertise active/standby state.
For 1:1 protection model, the operation would be as follows:
o ICCP deployment option: ICCP is deployed on VPLS edge nodes in
both domains;
o PW redundancy mode: independent mode only;
o Protection architectures: 1:1(1 standby, 1 active).
The switchover rules described in section 5.1 apply. In this case,
the operators do not need to do any coordination of the inter-domain
PW priority. The PE detecting one PW DOWN SHOULD set the other PW to
STANDBY if available, and then synchronize the updated state to its
ICCP peer. When a PE detects that the PWs from ICCP peer PE are DOWN
or STANDBY, it SHOULD switchover as described in section 5.1.1.
There are two variants of the 3:1 protection model. We will refer to
them as options A and B. The implementation MUST support option A,
and MAY support option B. Option B will be useful when the two legacy
PEs in one domain does not support the function in this document.
The two legacy PEs still need to support PW redundancy defined in
[RFC6870], and be configured as slave node.
For option A of the 3:1 protection model, the support of Request
Switchover status bit [RFC6870] is required. The operation is as
follows:
o ICCP deployment option: ICCP is deployed on VPLS edge nodes in
both domains;
o PW redundancy mode: Independent mode with 'request switchover' bit
support;
Liu, et al. Expires October 26, 2014 [Page 7]
Internet-Draft Redundancy for VPLS Inter-domain April 2014
o Protection architectures: 3:1 (3 standby, 1 active).
In this case, the procedure on the PE for the PW failure is per
section 6.3 of [RFC6870], and with the following additions:
o When the PE detects failure of the active inter-domain PW, it
SHOULD switch to the other local standby inter-domain PW if
available, and send an updated LDP PW status message with the
'request switchover' bit set on that local standby inter-domain PW
to the remote PE;
o Local and remote PE SHOULD also update the new PW status to their
ICCP peers, respectively, in Application Data Messages with PW-RED
Synchronization Request TLV for corresponding service, so as to
synchronize the latest PW status on both PE sides.
o While waiting for the acknowledgement, the PE that sends the
'request switchover' bit may receive a switchover request from its
ICCP peer's PW remote endpoint by virtue of the ICCP
synchronization. The PE MUST compare IP addresses with that PW
remote peer. The PE with a higher IP address SHOULD ignore the
request and continue to wait for the acknowledgement from its peer
in the remote domain. The PE with the lower IP address SHOULD
clear 'request switchover' bit and set 'Preferential Forwarding'
local status bit, and update the PW status to ICCP peer.
o The remote PE receiving 'request switchover' bit SHOULD
acknowledge the request and activate the PW only when it is ready
to take over as described in section 5.1, otherwise, it SHOULD
ignore the request.
The node isolation failure and node failure is described in section
5.1.
For option B of 3:1 protection model, master/slave mode support is
required, and should be as follows:
o ICCP deployment option: ICCP is deployed on VPLS edge nodes in
only one domain;
o PW redundancy mode: master/slave only;
o Protection architectures: 3:1 (3 standby, 1 active).
When master/slave PW redundancy mode is employed, the network
operators of two domains must agree on which domain PEs will be
master, and configure the devices accordingly. The inter-domain PWs
that connect to one PE should have higher PW priority than the PWs on
the other PE in the same RG. The procedure on the PE for PW failure
is as follows:
o The PE with higher PW priority should only enable one PW active,
and the other PWs standby.
o When the PE detects active PW DOWN, it SHOULD enable the other
local standby PW to be active with preference. Only when two
inter-domain PWs connect to the PE are DOWN, the ICCP peer PE in
Liu, et al. Expires October 26, 2014 [Page 8]
Internet-Draft Redundancy for VPLS Inter-domain April 2014
the same RG SHOULD switchover as described in section 5.1.
The node isolation failure and node failure is described in section
5.1.
6. Management Considerations
When deploying the inter-domain redundancy mechanism described in
this document, consistent provisioning is required for proper
operation. The two domains must both use the same use case (section
5.2 or section 5.3). Within each section, all of the described modes
and options must be provisioned identically both within each RG and
between the RGs. Additionally, for the two-PWs redundancy options
defined in section 5.2, the two operators must also negotiate to
configure same high/low PW priority at the two PW end-points. If the
provisioning is inconsistent, then the inter-domain redundancy
mechanism may not work properly.
7. Security Considerations
Besides the security properties of [I-D.ietf-pwe3-iccp] for ICCP
control plane, [RFC4762] and [RFC6870] for PW control plane, this
document has additional security consideration for ICCP control
plane.
In this document, ICCP protocol is deployed between two PEs or ASBRs.
The two PEs or ASBRs should only be connected by a well managed and
highly monitored network. This should be ensured by the operator.
The state flapping on the inter-domain and intra-domain PW may cause
security threats or be exploited to create denial of service attacks.
For example, excessive PW state flapping (e.g., by malicious peer
PE's implementation) may lead to excessive ICCP exchanges.
Implementations SHOULD provide mechanisms to perform control-plane
policing and mitigate such types of attacks.
8. IANA Consideration
No IANA allocation is required in this document.
9. Acknowledgements
The author would like to thank Sami Boutros, Giles Heron, Adrian
Farrel, Andrew G. Malis and Stephen Kent for their valuable comments.
Liu, et al. Expires October 26, 2014 [Page 9]
Internet-Draft Redundancy for VPLS Inter-domain April 2014
10. Contributors
Daniel Cohn
Email:daniel.cohn.ietf@gmail.com
Yubao Wang
ZTE Corporation
Nanjing, China
Email: wang.yubao@zte.com.cn
11. References
11.1. Normative references
[I-D.ietf-pwe3-iccp]
Martini, L., Salam, S., Sajassi, A., and S. Matsushima,
"Inter-Chassis Communication Protocol for L2VPN PE
Redundancy", draft-ietf-pwe3-iccp-16 (work in progress),
March 2014.
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119, March 1997.
[RFC6870] Muley, P. and M. Aissaoui, "Pseudowire Preferential
Forwarding Status Bit", RFC 6870, February 2013.
11.2. Informative references
[RFC4364] Rosen, E. and Y. Rekhter, "BGP/MPLS IP Virtual Private
Networks (VPNs)", RFC 4364, February 2006.
[RFC4762] Lasserre, M. and V. Kompella, "Virtual Private LAN Service
(VPLS) Using Label Distribution Protocol (LDP) Signaling",
RFC 4762, January 2007.
[RFC6074] Rosen, E., Davie, B., Radoaca, V., and W. Luo,
"Provisioning, Auto-Discovery, and Signaling in Layer 2
Virtual Private Networks (L2VPNs)", RFC 6074,
January 2011.
[RFC6718] Muley, P., Aissaoui, M., and M. Bocci, "Pseudowire
Redundancy", RFC 6718, August 2012.
[RFC7117] Aggarwal, R., Kamite, Y., Fang, L., Rekhter, Y., and C.
Kodeboniya, "Multicast in Virtual Private LAN Service
(VPLS)", RFC 7117, February 2014.
Liu, et al. Expires October 26, 2014 [Page 10]
Internet-Draft Redundancy for VPLS Inter-domain April 2014
Authors' Addresses
Zhihua Liu
China Telecom
109 Zhongshan Ave.
Guangzhou 510630
P.R.China
Email: zhliu@gsta.com
Lizhong Jin
Shanghai
P.R.China
Email: lizho.jin@gmail.com
Ran Chen
ZTE Corporation
NO.19 East Huayuan Road
Haidian District Beijing 100191
P.R.China
Email: chen.ran@zte.com.cn
Dennis Cai
Cisco
3750 Cisco Way,
San Jose, California 95134
USA
Email: dcai@cisco.com
Samer Salam
Cisco
595 Burrard Street, Suite:2123
Vancouver, BC V7X 1J1
Canada
Email: ssalam@cisco.com