Network Working Group M. Bjorklund Internet-Draft Tail-f Systems Intended status: Standards Track L. Lhotka Expires: November 17, 2017 CZ.NIC May 16, 2017 YANG Schema Mount draft-ietf-netmod-schema-mount-05 Abstract This document defines a mechanism to combine YANG modules into the schema defined in other YANG modules. Status of This Memo This Internet-Draft is submitted in full conformance with the provisions of BCP 78 and BCP 79. Internet-Drafts are working documents of the Internet Engineering Task Force (IETF). Note that other groups may also distribute working documents as Internet-Drafts. The list of current Internet- Drafts is at http://datatracker.ietf.org/drafts/current/. Internet-Drafts are draft documents valid for a maximum of six months and may be updated, replaced, or obsoleted by other documents at any time. It is inappropriate to use Internet-Drafts as reference material or to cite them other than as "work in progress." This Internet-Draft will expire on November 17, 2017. Copyright Notice Copyright (c) 2017 IETF Trust and the persons identified as the document authors. All rights reserved. This document is subject to BCP 78 and the IETF Trust's Legal Provisions Relating to IETF Documents (http://trustee.ietf.org/license-info) in effect on the date of publication of this document. Please review these documents carefully, as they describe your rights and restrictions with respect to this document. Code Components extracted from this document must include Simplified BSD License text as described in Section 4.e of the Trust Legal Provisions and are provided without warranty as described in the Simplified BSD License. Bjorklund & Lhotka Expires November 17, 2017 [Page 1]
Internet-Draft YANG Schema Mount May 2017 Table of Contents 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . 2 2. Terminology and Notation . . . . . . . . . . . . . . . . . . 5 2.1. Glossary of New Terms . . . . . . . . . . . . . . . . . . 6 2.2. Tree Diagrams . . . . . . . . . . . . . . . . . . . . . . 6 2.3. Namespace Prefixes . . . . . . . . . . . . . . . . . . . 6 3. Schema Mount . . . . . . . . . . . . . . . . . . . . . . . . 7 3.1. Mount Point Definition . . . . . . . . . . . . . . . . . 7 3.2. Specification of the Mounted Schema . . . . . . . . . . . 7 3.3. Multiple Levels of Schema Mount . . . . . . . . . . . . . 9 4. Referring to Data Nodes in the Parent Schema . . . . . . . . 9 5. RPC operations and Notifications . . . . . . . . . . . . . . 10 6. Implementation Notes . . . . . . . . . . . . . . . . . . . . 11 7. Data Model . . . . . . . . . . . . . . . . . . . . . . . . . 11 8. Schema Mount YANG Module . . . . . . . . . . . . . . . . . . 13 9. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 18 10. Security Considerations . . . . . . . . . . . . . . . . . . . 18 11. Contributors . . . . . . . . . . . . . . . . . . . . . . . . 18 12. References . . . . . . . . . . . . . . . . . . . . . . . . . 19 12.1. Normative References . . . . . . . . . . . . . . . . . . 19 12.2. Informative References . . . . . . . . . . . . . . . . . 19 Appendix A. Example: Device Model with LNEs and NIs . . . . . . 20 A.1. Physical Device . . . . . . . . . . . . . . . . . . . . . 20 A.2. Logical Network Elements . . . . . . . . . . . . . . . . 22 A.3. Network Instances . . . . . . . . . . . . . . . . . . . . 25 A.4. Invoking an RPC Operation . . . . . . . . . . . . . . . . 27 Appendix B. Open Issues . . . . . . . . . . . . . . . . . . . . 27 B.1. RPC Operations and Notifications in Mounted Modules . . . 27 B.2. Tree Representation . . . . . . . . . . . . . . . . . . . 27 B.3. Design-Time Mounts . . . . . . . . . . . . . . . . . . . 28 Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . . 28 1. Introduction Modularity and extensibility were among the leading design principles of the YANG data modeling language. As a result, the same YANG module can be combined with various sets of other modules and thus form a data model that is tailored to meet the requirements of a specific use case. Server implementors are only required to specify all YANG modules comprising the data model (together with their revisions and other optional choices) in the YANG library data ([RFC7895], and Section 5.6.4 of [RFC7950]) implemented by the server. Such YANG modules appear in the data model "side by side", i.e., top-level data nodes of each module - if there are any - are also top-level nodes of the overall data model. Bjorklund & Lhotka Expires November 17, 2017 [Page 2]
Internet-Draft YANG Schema Mount May 2017 Furthermore, YANG has two mechanisms for contributing a schema hierarchy defined elsewhere to the contents of an internal node of the schema tree; these mechanisms are realized through the following YANG statements: o The "uses" statement explicitly incorporates the contents of a grouping defined in the same or another module. See Section 4.2.6 of [RFC7950] for more details. o The "augment" statement explicitly adds contents to a target node defined in the same or another module. See Section 4.2.8 of [RFC7950] for more details. With both mechanisms, the source or target YANG module explicitly defines the exact location in the schema tree where the new nodes are placed. In some cases these mechanisms are not sufficient; it is often necessary that an existing module (or a set of modules) is added to the data model starting at a non-root location. For example, YANG modules such as "ietf-interfaces" [RFC7223] are often defined so as to be used in a data model of a physical device. Now suppose we want to model a device that supports multiple logical devices [I-D.ietf-rtgwg-lne-model], each of which has its own instantiation of "ietf-interfaces", and possibly other modules, but, at the same time, we want to be able to manage all these logical devices from the master device. Hence, we would like to have a schema like this: +--rw interfaces | +--rw interface* [name] | ... +--rw logical-device* [name] +--rw name | ... +--rw interfaces +--rw interface* [name] ... With the "uses" approach, the complete schema tree of "ietf-interfaces" would have to be wrapped in a grouping, and then this grouping would have to be used at the top level (for the master device) and then also in the "logical-device" list (for the logical devices). This approach has several disadvantages: o It is not scalable because every time there is a new YANG module that needs to be added to the logical device model, we have to update the model for logical devices with another "uses" statement pulling in contents of the new module. Bjorklund & Lhotka Expires November 17, 2017 [Page 3]
Internet-Draft YANG Schema Mount May 2017 o Absolute references to nodes defined inside a grouping may break if the grouping is used in different locations. o Nodes defined inside a grouping belong to the namespace of the module where it is used, which makes references to such nodes from other modules difficult or even impossible. o It would be difficult for vendors to add proprietary modules when the "uses" statements are defined in a standard module. With the "augment" approach, "ietf-interfaces" would have to augment the "logical-device" list with all its nodes, and at the same time define all its nodes at the top level. The same hierarchy of nodes would thus have to be defined twice, which is clearly not scalable either. This document introduces a new generic mechanism, denoted as schema mount, that allows for mounting one data model consisting of any number of YANG modules at a specified location of another (parent) schema. Unlike the "uses" and "augment" approaches discussed above, the mounted modules needn't be specially prepared for mounting and, consequently, existing modules such as "ietf-interfaces" can be mounted without any modifications. The basic idea of schema mount is to label a data node in the parent schema as the mount point, and then define a complete data model to be attached to the mount point so that the labeled data node effectively becomes the root node of the mounted data model. In principle, the mounted schema can be specified at three different phases of the data model life cycle: 1. Design-time: the mounted schema is defined along with the mount point in the parent module. In this case, the mounted schema has to be the same for every implementation of the parent module. 2. Implementation-time: the mounted schema is defined by a server implementor and is as stable as YANG library information, i.e., it may change after an upgrade of server software but not after rebooting the server. Also, a client can learn the entire schema together with YANG library data. 3. Run-time: the mounted schema is defined by instance data that is part of the mounted data model. If there are multiple instances of the same mount point (e.g., in multiple entries of a list), the mounted data model may be different for each instance. Bjorklund & Lhotka Expires November 17, 2017 [Page 4]
Internet-Draft YANG Schema Mount May 2017 The schema mount mechanism defined in this document provides support only for the latter two cases because design-time definition of the mounted schema doesn't play well with the existing YANG modularity mechanisms. For example, it would be impossible to augment the mounted data model. Schema mount applies to the data model, and specifically does not assume anything about the source of instance data for the mounted schemas. It may be implemented using the same instrumentation as the rest of the system, or it may be implemented by querying some other system. Future specifications may define mechanisms to control or monitor the implementation of specific mount points. This document allows mounting of complete data models only. Other specifications may extend this model by defining additional mechanisms such as mounting sub-hierarchies of a module. 2. Terminology and Notation The keywords "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in BCP 14, [RFC2119]. The following terms are defined in [RFC6241] and are not redefined here: o client o notification o server The following terms are defined in [RFC7950] and are not redefined here: o action o configuration data o container o list o operation The following terms are defined in [RFC7223] and are not redefined here: Bjorklund & Lhotka Expires November 17, 2017 [Page 5]
Internet-Draft YANG Schema Mount May 2017 o system-controlled interface 2.1. Glossary of New Terms o inline schema: a mounted schema whose definition is provided as part of the mounted data, using YANG library [RFC7895]. o mount point: container or list node whose definition contains the "mount-point" extension statement. The argument of the "mount-point" statement defines the name of the mount point. o parent schema (of a particular mounted schema): the schema that contains the mount point for the mounted schema. o top-level schema: a schema according to [RFC7950] in which schema trees of each module (except augments) start at the root node. 2.2. Tree Diagrams A simplified graphical representation of the data model is used in this document. The meaning of the symbols in these diagrams is as follows: o Brackets "[" and "]" enclose list keys. o Abbreviations before data node names: "rw" means configuration data (read-write) and "ro" state data (read-only). o Symbols after data node names: "?" means an optional node, "!" means a presence container, and "*" denotes a list and leaf-list. o Parentheses enclose choice and case nodes, and case nodes are also marked with a colon (":"). o Ellipsis ("...") stands for contents of subtrees that are not shown. 2.3. Namespace Prefixes In this document, names of data nodes, YANG extensions, actions and other data model objects are often used without a prefix, as long as it is clear from the context in which YANG module each name is defined. Otherwise, names are prefixed using the standard prefix associated with the corresponding YANG module, as shown in Table 1. Bjorklund & Lhotka Expires November 17, 2017 [Page 6]
Internet-Draft YANG Schema Mount May 2017 +---------+------------------------+-----------+ | Prefix | YANG module | Reference | +---------+------------------------+-----------+ | yangmnt | ietf-yang-schema-mount | Section 8 | | inet | ietf-inet-types | [RFC6991] | | yang | ietf-yang-types | [RFC6991] | | yanglib | ietf-yang-library | [RFC7895] | +---------+------------------------+-----------+ Table 1: Namespace Prefixes 3. Schema Mount The schema mount mechanism defined in this document provides a new extensibility mechanism for use with YANG 1.1. In contrast to the existing mechanisms described in Section 1, schema mount defines the relationship between the source and target YANG modules outside these modules. The procedure consists of two separate steps that are described in the following subsections. 3.1. Mount Point Definition A "container" or "list" node becomes a mount point if the "mount-point" extension (defined in the "ietf-yang-schema-mount" module) is used in its definition. This extension can appear only as a substatement of "container" and "list" statements. The argument of the "mount-point" extension is a YANG identifier that defines the name of the mount point. A module MAY contain multiple "mount-point" statements having the same argument. It is therefore up to the designer of the parent schema to decide about the placement of mount points. A mount point can also be made conditional by placing "if-feature" and/or "when" as substatements of the "container" or "list" statement that represents the mount point. The "mount-point" statement MUST NOT be used in a YANG version 1 module. Note, however, that modules written in any YANG version, including version 1, can be mounted under a mount point. 3.2. Specification of the Mounted Schema Mounted schemas for all mount points in the parent schema are determined from state data in the "yangmnt:schema-mounts" container. Data in this container is intended to be as stable as data in the top-level YANG library [RFC7895]. In particular, it SHOULD NOT change during the same management session. Bjorklund & Lhotka Expires November 17, 2017 [Page 7]
Internet-Draft YANG Schema Mount May 2017 The "schema-mounts" container has the "mount-point" list as one of its children. Every entry of this list refers through its key to a mount point and specifies the mounted schema. If a mount point is defined in the parent schema but does not have an entry in the "mount-point" list, then the mounted schema is void, i.e., instances of that mount point MUST NOT contain any data above those that are defined in the parent schema. If multiple mount points with the same name are defined in the same module - either directly or because the mount point is defined in a grouping and the grouping is used multiple times - then the corresponding "mount-point" entry applies equally to all such mount points. The "config" property of mounted schema nodes is overridden and all nodes in the mounted schema are read-only ("config false") if at least one of the following conditions is satisfied for a mount point: o the mount point is itself defined as "config false" o the "config" leaf in the corresponding entry of the "mount-point" list is set to "false". An entry of the "mount-point" list can specify the mounted schema in two different ways: 1. by stating that the schema is available inline, i.e., in run-time instance data; or 2. by referring to one or more entries of the "schema" list in the same instance of "schema-mounts". In case 1, the mounted schema is determined at run time: every instance of the mount point that exists in the parent tree MUST contain a copy of YANG library data [RFC7895] that defines the mounted schema exactly as for a top-level data model. A client is expected to retrieve this data from the instance tree, possibly after creating the mount point. Instances of the same mount point MAY use different mounted schemas. In case 2, the mounted schema is defined by the combination of all "schema" entries referred to in the "use-schema" list. In this case, the mounted schema is specified as implementation-time data that can be retrieved together with YANG library data for the parent schema, i.e., even before any instances of the mount point exist. However, the mounted schema has to be the same for all instances of the mount point. Bjorklund & Lhotka Expires November 17, 2017 [Page 8]
Internet-Draft YANG Schema Mount May 2017 Each entry of the "schema" list contains o a list in the YANG library format specifying all YANG modules (and revisions etc.) that are implemented or imported in the mounted schema; o (optionally) a new "mount-point" list that applies to mount points defined within the mounted schema. 3.3. Multiple Levels of Schema Mount YANG modules in a mounted schema MAY again contain mount points under which subschemas can be mounted. Consequently, it is possible to construct data models with an arbitrary number of schema levels. A subschema for a mount point contained in a mounted module can be specified in one of the following ways: o by implementing "ietf-yang-library" and "ietf-yang-schema-mount" modules in the mounted schema, and specifying the subschemas exactly as it is done in the top-level schema o by using the "mount-point" list inside the corresponding "schema" entry. The former method is applicable to both "inline" and "use-schema" cases whereas the latter requires the "use-schema" case. On the other hand, the latter method allows for a compact representation of a multi-level schema the does not rely on the presence of any instance data. 4. Referring to Data Nodes in the Parent Schema A fundamental design principle of schema mount is that the mounted data model works exactly as a top-level data model, i.e., it is confined to the "mount jail". This means that all paths in the mounted data model (in leafrefs, instance-identifiers, XPath expressions, and target nodes of augments) are interpreted with the mount point as the root node. YANG modules of the mounted schema as well as corresponding instance data thus cannot refer to schema nodes or instance data outside the mount jail. However, this restriction is sometimes too severe. A typical example is network instances (NI) [I-D.ietf-rtgwg-ni-model], where each NI has its own routing engine but the list of interfaces is global and shared by all NIs. If we want to model this organization with the NI schema mounted using schema mount, the overall schema tree would look schematically as follows: Bjorklund & Lhotka Expires November 17, 2017 [Page 9]
Internet-Draft YANG Schema Mount May 2017 +--rw interfaces | +--rw interface* [name] | ... +--rw network-instances +--rw network-instance* [name] +--rw name +--rw root +--rw routing ... Here, the "root" node is the mount point for the NI schema. Routing configuration inside an NI often needs to refer to interfaces (at least those that are assigned to the NI), which is impossible unless such a reference can point to a node in the parent schema (interface name). Therefore, schema mount also allows for such references. For every schema mounted using the "use-schema" method, it is possible to specify a leaf-list named "parent-reference" that contains zero or more XPath 1.0 expressions. Each expression is evaluated with the root of the parent data tree as the context node and the result MUST be a nodeset (see the description of the "parent-reference" node for a complete definition of the evaluation context). For the purposes of evaluating XPath expressions within the mounted data tree, the union of all such nodesets is added to the accessible data tree. It is worth emphasizing that o The nodes specified in "parent-reference" leaf-list are available in the mounted schema only for XPath evaluations. In particular, they cannot be accessed there via network management protocols such as NETCONF [RFC6241] or RESTCONF [RFC8040]. o The mechanism of referencing nodes in the parent schema is not available for schemas mounted using the "inline" method. 5. RPC operations and Notifications If a mounted YANG module defines an RPC operation, clients can invoke this operation by representing it as an action defined for the corresponding mount point, see Section 7.15 of ^RFC7950. An example of this is given in Appendix A.4. Similarly, if the server emits a notification defined at the top level of any mounted module, it MUST be represented as if the notification was connected to the mount point, see Section 7.16 of [RFC7950]. Bjorklund & Lhotka Expires November 17, 2017 [Page 10]
Internet-Draft YANG Schema Mount May 2017 6. Implementation Notes Network management of devices that use a data model with schema mount can be implemented in different ways. However, the following implementations options are envisioned as typical: o shared management: instance data of both parent and mounted schemas are accessible within the same management session. o split management: one (master) management session has access to instance data of both parent and mounted schemas but, in addition, an extra session exists for every instance of the mount point, having access only to the mounted data tree. 7. Data Model This document defines the YANG 1.1 module [RFC7950] "ietf-yang-schema-mount", which has the following structure: Bjorklund & Lhotka Expires November 17, 2017 [Page 11]
Internet-Draft YANG Schema Mount May 2017 module: ietf-yang-schema-mount +--ro schema-mounts +--ro namespace* [prefix] | +--ro prefix yang:yang-identifier | +--ro ns-uri? inet:uri +--ro mount-point* [module name] | +--ro module yang:yang-identifier | +--ro name yang:yang-identifier | +--ro config? boolean | +--ro (schema-ref)? | +--:(inline) | | +--ro inline? empty | +--:(use-schema) | +--ro use-schema* [name] | +--ro name | | -> /schema-mounts/schema/name | +--ro parent-reference* yang:xpath1.0 +--ro schema* [name] +--ro name string +--ro module* [name revision] | +--ro name yang:yang-identifier | +--ro revision union | +--ro schema? inet:uri | +--ro namespace inet:uri | +--ro feature* yang:yang-identifier | +--ro deviation* [name revision] | | +--ro name yang:yang-identifier | | +--ro revision union | +--ro conformance-type enumeration | +--ro submodule* [name revision] | +--ro name yang:yang-identifier | +--ro revision union | +--ro schema? inet:uri +--ro mount-point* [module name] +--ro module yang:yang-identifier +--ro name yang:yang-identifier +--ro config? boolean +--ro (schema-ref)? +--:(inline) | +--ro inline? empty +--:(use-schema) +--ro use-schema* [name] +--ro name | -> /schema-mounts/schema/name +--ro parent-reference* yang:xpath1.0 Bjorklund & Lhotka Expires November 17, 2017 [Page 12]
Internet-Draft YANG Schema Mount May 2017 8. Schema Mount YANG Module This module references [RFC6991] and [RFC7895]. <CODE BEGINS> file "ietf-yang-schema-mount@2017-05-16.yang" module ietf-yang-schema-mount { yang-version 1.1; namespace "urn:ietf:params:xml:ns:yang:ietf-yang-schema-mount"; prefix yangmnt; import ietf-inet-types { prefix inet; reference "RFC 6991: Common YANG Data Types"; } import ietf-yang-types { prefix yang; reference "RFC 6991: Common YANG Data Types"; } import ietf-yang-library { prefix yanglib; reference "RFC 7895: YANG Module Library"; } organization "IETF NETMOD (NETCONF Data Modeling Language) Working Group"; contact "WG Web: <https://tools.ietf.org/wg/netmod/> WG List: <mailto:netmod@ietf.org> Editor: Martin Bjorklund <mailto:mbj@tail-f.com> Editor: Ladislav Lhotka <mailto:lhotka@nic.cz>"; description "This module defines a YANG extension statement that can be used to incorporate data models defined in other YANG modules in a module. It also defines operational state data that specify the overall structure of the data model. Bjorklund & Lhotka Expires November 17, 2017 [Page 13]
Internet-Draft YANG Schema Mount May 2017 Copyright (c) 2017 IETF Trust and the persons identified as authors of the code. All rights reserved. Redistribution and use in source and binary forms, with or without modification, is permitted pursuant to, and subject to the license terms contained in, the Simplified BSD License set forth in Section 4.c of the IETF Trust's Legal Provisions Relating to IETF Documents (https://trustee.ietf.org/license-info). The key words 'MUST', 'MUST NOT', 'REQUIRED', 'SHALL', 'SHALL NOT', 'SHOULD', 'SHOULD NOT', 'RECOMMENDED', 'MAY', and 'OPTIONAL' in the module text are to be interpreted as described in RFC 2119 (https://tools.ietf.org/html/rfc2119). This version of this YANG module is part of RFC XXXX (https://tools.ietf.org/html/rfcXXXX); see the RFC itself for full legal notices."; revision 2017-05-16 { description "Initial revision."; reference "RFC XXXX: YANG Schema Mount"; } /* * Extensions */ extension mount-point { argument name; description "The argument 'name' is a YANG identifier, i.e., it is of the type 'yang:yang-identifier'. The 'mount-point' statement MUST NOT be used in a YANG version 1 module, neither explicitly nor via a 'uses' statement. The 'mount-point' statement MAY be present as a substatement of 'container' and 'list', and MUST NOT be present elsewhere. If a mount point is defined in a grouping, its name is bound to the module where the grouping is used. A mount point defines a place in the node hierarchy where other data models may be attached. A server that implements a Bjorklund & Lhotka Expires November 17, 2017 [Page 14]
Internet-Draft YANG Schema Mount May 2017 module with a mount point populates the /schema-mounts/mount-point list with detailed information on which data models are mounted at each mount point."; } /* * Groupings */ grouping mount-point-list { description "This grouping is used inside the 'schema-mounts' container and inside the 'schema' list."; list mount-point { key "module name"; description "Each entry of this list specifies a schema for a particular mount point. Each mount point MUST be defined using the 'mount-point' extension in one of the modules listed in the corresponding YANG library instance with conformance type 'implement'. The corresponding YANG library instance is: - standard YANG library state data as defined in RFC 7895, if the 'mount-point' list is a child of 'schema-mounts', - the contents of the sibling 'yanglib:modules-state' container, if the 'mount-point' list is a child of 'schema'."; leaf module { type yang:yang-identifier; description "Name of a module containing the mount point."; } leaf name { type yang:yang-identifier; description "Name of the mount point defined using the 'mount-point' extension."; } leaf config { type boolean; default "true"; description "If this leaf is set to 'false', then all data nodes in the mounted schema are read-only (config false), regardless of their 'config' property."; Bjorklund & Lhotka Expires November 17, 2017 [Page 15]
Internet-Draft YANG Schema Mount May 2017 } choice schema-ref { description "Alternatives for specifying the schema."; leaf inline { type empty; description "This leaf indicates that the server has mounted 'ietf-yang-library' and 'ietf-schema-mount' at the mount point, and their instantiation (i.e., state data containers 'yanglib:modules-state' and 'schema-mounts') provides the information about the mounted schema."; } list use-schema { key "name"; description "Each entry of this list contains a reference to a schema defined in the /schema-mounts/schema list."; leaf name { type leafref { path "/schema-mounts/schema/name"; } description "Name of the referenced schema."; } leaf-list parent-reference { type yang:xpath1.0; description "Entries of this leaf-list are XPath 1.0 expressions that are evaluated in the following context: - The context node is the root node of the parent data tree. - The accessible tree is the parent data tree *without* any nodes defined in modules that are mounted inside the parent schema. - The context position and context size are both equal to 1. - The set of variable bindings is empty. - The function library is the core function library defined in [XPath] and the functions defined in Section 10 of [RFC7950]. - The set of namespace declarations is defined by the Bjorklund & Lhotka Expires November 17, 2017 [Page 16]
Internet-Draft YANG Schema Mount May 2017 'namespace' list under 'schema-mounts'. Each XPath expression MUST evaluate to a nodeset (possibly empty). For the purposes of evaluating XPath expressions whose context nodes are defined in the mounted schema, the union of all these nodesets together with ancestor nodes are added to the accessible data tree."; } } } } } /* * State data nodes */ container schema-mounts { config false; description "Contains information about the structure of the overall mounted data model implemented in the server."; list namespace { key "prefix"; description "This list provides a mapping of namespace prefixes that are used in XPath expressions of 'parent-reference' leafs to the corresponding namespace URI references."; leaf prefix { type yang:yang-identifier; description "Namespace prefix."; } leaf ns-uri { type inet:uri; description "Namespace URI reference."; } } uses mount-point-list; list schema { key "name"; description "Each entry specifies a schema that can be mounted at a mount point. The schema information consists of two parts: - an instance of YANG library that defines YANG modules used Bjorklund & Lhotka Expires November 17, 2017 [Page 17]
Internet-Draft YANG Schema Mount May 2017 in the schema, - mount-point list with content identical to the top-level mount-point list (this makes the schema structure recursive)."; leaf name { type string; description "Arbitrary name of the schema entry."; } uses yanglib:module-list; uses mount-point-list; } } } <CODE ENDS> 9. IANA Considerations This document registers a URI in the IETF XML registry [RFC3688]. Following the format in RFC 3688, the following registration is requested to be made. URI: urn:ietf:params:xml:ns:yang:ietf-yang-schema-mount Registrant Contact: The IESG. XML: N/A, the requested URI is an XML namespace. This document registers a YANG module in the YANG Module Names registry [RFC6020]. name: ietf-yang-schema-mount namespace: urn:ietf:params:xml:ns:yang:ietf-yang-schema-mount prefix: yangmnt reference: RFC XXXX 10. Security Considerations TBD 11. Contributors The idea of having some way to combine schemas from different YANG modules into one has been proposed independently by several groups of people: Alexander Clemm, Jan Medved, and Eric Voit ([I-D.clemm-netmod-mount]); and Lou Berger and Christian Hopps: Bjorklund & Lhotka Expires November 17, 2017 [Page 18]
Internet-Draft YANG Schema Mount May 2017 o Lou Berger, LabN Consulting, L.L.C., <lberger@labn.net> o Alexander Clemm, Huawei, <alexander.clemm@huawei.com> o Christian Hopps, Deutsche Telekom, <chopps@chopps.org> o Jan Medved, Cisco, <jmedved@cisco.com> o Eric Voit, Cisco, <evoit@cisco.com> 12. References 12.1. Normative References [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate Requirement Levels", BCP 14, RFC 2119, DOI 10.17487/RFC2119, March 1997, <http://www.rfc-editor.org/info/rfc2119>. [RFC3688] Mealling, M., "The IETF XML Registry", BCP 81, RFC 3688, DOI 10.17487/RFC3688, January 2004, <http://www.rfc-editor.org/info/rfc3688>. [RFC6020] Bjorklund, M., Ed., "YANG - A Data Modeling Language for the Network Configuration Protocol (NETCONF)", RFC 6020, DOI 10.17487/RFC6020, October 2010, <http://www.rfc-editor.org/info/rfc6020>. [RFC6991] Schoenwaelder, J., Ed., "Common YANG Data Types", RFC 6991, DOI 10.17487/RFC6991, July 2013, <http://www.rfc-editor.org/info/rfc6991>. [RFC7895] Bierman, A., Bjorklund, M., and K. Watsen, "YANG Module Library", RFC 7895, DOI 10.17487/RFC7895, June 2016, <http://www.rfc-editor.org/info/rfc7895>. [RFC7950] Bjorklund, M., Ed., "The YANG 1.1 Data Modeling Language", RFC 7950, DOI 10.17487/RFC7950, August 2016, <http://www.rfc-editor.org/info/rfc7950>. 12.2. Informative References [I-D.clemm-netmod-mount] Clemm, A., Voit, E., and J. Medved, "Mounting YANG-Defined Information from Remote Datastores", draft-clemm-netmod- mount-06 (work in progress), March 2017. Bjorklund & Lhotka Expires November 17, 2017 [Page 19]
Internet-Draft YANG Schema Mount May 2017 [I-D.ietf-isis-yang-isis-cfg] Litkowski, S., Yeung, D., Lindem, A., Zhang, Z., and L. Lhotka, "YANG Data Model for IS-IS protocol", draft-ietf- isis-yang-isis-cfg-17 (work in progress), March 2017. [I-D.ietf-rtgwg-device-model] Lindem, A., Berger, L., Bogdanovic, D., and C. Hopps, "Network Device YANG Logical Organization", draft-ietf- rtgwg-device-model-02 (work in progress), March 2017. [I-D.ietf-rtgwg-lne-model] Berger, L., Hopps, C., Lindem, A., and D. Bogdanovic, "YANG Logical Network Elements", draft-ietf-rtgwg-lne- model-02 (work in progress), March 2017. [I-D.ietf-rtgwg-ni-model] Berger, L., Hopps, C., Lindem, A., and D. Bogdanovic, "YANG Network Instances", draft-ietf-rtgwg-ni-model-02 (work in progress), March 2017. [RFC6241] Enns, R., Ed., Bjorklund, M., Ed., Schoenwaelder, J., Ed., and A. Bierman, Ed., "Network Configuration Protocol (NETCONF)", RFC 6241, DOI 10.17487/RFC6241, June 2011, <http://www.rfc-editor.org/info/rfc6241>. [RFC7223] Bjorklund, M., "A YANG Data Model for Interface Management", RFC 7223, DOI 10.17487/RFC7223, May 2014, <http://www.rfc-editor.org/info/rfc7223>. [RFC8040] Bierman, A., Bjorklund, M., and K. Watsen, "RESTCONF Protocol", RFC 8040, DOI 10.17487/RFC8040, January 2017, <http://www.rfc-editor.org/info/rfc8040>. Appendix A. Example: Device Model with LNEs and NIs This non-normative example demonstrates an implementation of the device model as specified in Section 2 of [I-D.ietf-rtgwg-device-model], using both logical network elements (LNE) and network instances (NI). A.1. Physical Device The data model for the physical device may be described by this YANG library content: "ietf-yang-library:modules-state": { "module-set-id": "14e2ab5dc325f6d86f743e8d3ade233f1a61a899", "module": [ Bjorklund & Lhotka Expires November 17, 2017 [Page 20]
Internet-Draft YANG Schema Mount May 2017 { "name": "iana-if-type", "revision": "2014-05-08", "namespace": "urn:ietf:params:xml:ns:yang:iana-if-type", "conformance-type": "implement" }, { "name": "ietf-inet-types", "revision": "2013-07-15", "namespace": "urn:ietf:params:xml:ns:yang:ietf-inet-types", "conformance-type": "import" }, { "name": "ietf-interfaces", "revision": "2014-05-08", "feature": [ "arbitrary-names", "pre-provisioning" ], "namespace": "urn:ietf:params:xml:ns:yang:ietf-interfaces", "conformance-type": "implement" }, { "name": "ietf-ip", "revision": "2014-06-16", "namespace": "urn:ietf:params:xml:ns:yang:ietf-ip", "conformance-type": "implement" }, { "name": "ietf-logical-network-element", "revision": "2016-10-21", "feature": [ "bind-lne-name" ], "namespace": "urn:ietf:params:xml:ns:yang:ietf-logical-network-element", "conformance-type": "implement" }, { "name": "ietf-yang-library", "revision": "2016-06-21", "namespace": "urn:ietf:params:xml:ns:yang:ietf-yang-library", "conformance-type": "implement" }, { "name": "ietf-yang-schema-mount", "revision": "2017-05-16", "namespace": Bjorklund & Lhotka Expires November 17, 2017 [Page 21]
Internet-Draft YANG Schema Mount May 2017 "urn:ietf:params:xml:ns:yang:ietf-yang-schema-mount", "conformance-type": "implement" }, { "name": "ietf-yang-types", "revision": "2013-07-15", "namespace": "urn:ietf:params:xml:ns:yang:ietf-yang-types", "conformance-type": "import" } ] } A.2. Logical Network Elements Each LNE can have a specific data model that is determined at run time, so it is appropriate to mount it using the "inline" method, hence the following "schema-mounts" data: "ietf-yang-schema-mount:schema-mounts": { "mount-point": [ { "module": "ietf-logical-network-element", "name": "root", "inline": [null] } ] } An administrator of the host device has to configure an entry for each LNE instance, for example, Bjorklund & Lhotka Expires November 17, 2017 [Page 22]
Internet-Draft YANG Schema Mount May 2017 { "ietf-interfaces:interfaces": { "interface": [ { "name": "eth0", "type": "iana-if-type:ethernetCsmacd", "enabled": true, "ietf-logical-network-element:bind-lne-name": "eth0" } ] }, "ietf-logical-network-element:logical-network-elements": { "logical-network-element": [ { "name": "lne-1", "managed": true, "description": "LNE with NIs", "root": { ... } }, ... ] } } and then also place necessary state data as the contents of the "root" instance, which should include at least o YANG library data specifying the LNE's data model, for example: "ietf-yang-library:modules-state": { "module-set-id": "9358e11874068c8be06562089e94a89e0a392019", "module": [ { "name": "iana-if-type", "revision": "2014-05-08", "namespace": "urn:ietf:params:xml:ns:yang:iana-if-type", "conformance-type": "implement" }, { "name": "ietf-inet-types", "revision": "2013-07-15", "namespace": "urn:ietf:params:xml:ns:yang:ietf-inet-types", "conformance-type": "import" }, { "name": "ietf-interfaces", Bjorklund & Lhotka Expires November 17, 2017 [Page 23]
Internet-Draft YANG Schema Mount May 2017 "revision": "2014-05-08", "feature": [ "arbitrary-names", "pre-provisioning" ], "namespace": "urn:ietf:params:xml:ns:yang:ietf-interfaces", "conformance-type": "implement" }, { "name": "ietf-ip", "revision": "2014-06-16", "feature": [ "ipv6-privacy-autoconf" ], "namespace": "urn:ietf:params:xml:ns:yang:ietf-ip", "conformance-type": "implement" }, { "name": "ietf-network-instance", "revision": "2016-10-27", "feature": [ "bind-network-instance-name" ], "namespace": "urn:ietf:params:xml:ns:yang:ietf-network-instance", "conformance-type": "implement" }, { "name": "ietf-yang-library", "revision": "2016-06-21", "namespace": "urn:ietf:params:xml:ns:yang:ietf-yang-library", "conformance-type": "implement" }, { "name": "ietf-yang-schema-mount", "revision": "2017-05-16", "namespace": "urn:ietf:params:xml:ns:yang:ietf-yang-schema-mount", "conformance-type": "implement" }, { "name": "ietf-yang-types", "revision": "2013-07-15", "namespace": "urn:ietf:params:xml:ns:yang:ietf-yang-types", "conformance-type": "import" } ] } Bjorklund & Lhotka Expires November 17, 2017 [Page 24]
Internet-Draft YANG Schema Mount May 2017 o state data for interfaces assigned to the LNE instance (that effectively become system-controlled interfaces for the LNE), for example: "ietf-interfaces:interfaces-state": { "interface": [ { "name": "eth0", "type": "iana-if-type:ethernetCsmacd", "oper-status": "up", "statistics": { "discontinuity-time": "2016-12-16T17:11:27+02:00" }, "ietf-ip:ipv6": { "address": [ { "ip": "fe80::42a8:f0ff:fea8:24fe", "origin": "link-layer", "prefix-length": 64 } ] } }, ... ] } A.3. Network Instances Assuming that network instances share the same data model, it can be mounted using the "use-schema" method as follows: Bjorklund & Lhotka Expires November 17, 2017 [Page 25]
Internet-Draft YANG Schema Mount May 2017 "ietf-yang-schema-mount:schema-mounts": { "mount-point": [ { "module": "ietf-network-instance", "name": "root", "parent-reference": ["ietf-interfaces"], "use-schema": [ { "name": "ni-schema" } ] } ], "schema": [ { "name": "ni-schema", "module": [ { "name": "ietf-ipv4-unicast-routing", "revision": "2016-11-04", "namespace": "urn:ietf:params:xml:ns:yang:ietf-ipv4-unicast-routing", "conformance-type": "implement" }, { "name": "ietf-ipv6-unicast-routing", "revision": "2016-11-04", "namespace": "urn:ietf:params:xml:ns:yang:ietf-ipv6-unicast-routing", "conformance-type": "implement" }, { "name": "ietf-routing", "revision": "2016-11-04", "feature": [ "multiple-ribs", "router-id" ], "namespace": "urn:ietf:params:xml:ns:yang:ietf-routing", "conformance-type": "implement" } ] } ] } Note also that the "ietf-interfaces" module appears in the "parent-reference" leaf-list for the mounted NI schema. This means Bjorklund & Lhotka Expires November 17, 2017 [Page 26]
Internet-Draft YANG Schema Mount May 2017 that references to LNE interfaces, such as "outgoing-interface" in static routes, are valid despite the fact that "ietf-interfaces" isn't part of the NI schema. A.4. Invoking an RPC Operation Assume that the mounted NI data model also implements the "ietf-isis" module [I-D.ietf-isis-yang-isis-cfg]. An RPC operation defined in this module, such as "clear-adjacency", can be invoked by a client session of a LNE's RESTCONF server as an action tied to a the mount point of a particular network instance using a request URI like this (all on one line): POST /restconf/data/ietf-network-instance:network-instances/ network-instance=rtrA/root/ietf-isis:clear-adjacency HTTP/1.1 Appendix B. Open Issues B.1. RPC Operations and Notifications in Mounted Modules Turning RPC operations defined in mounted modules into actions tied to the corresponding mount point (see Section 5, and similarly for notifications) is not possible if the path to the mount point in the parent schema contains a keyless list (Section 7.15 of [RFC7950]). The solutions for this corner case are possible: 1. any mount point MUST NOT have a keyless list among its ancestors 2. any mounted module MUST NOT contain RPC operations and/or notifications 3. specifically for each mount point, at least one of the above conditions MUST be satisfied. 4. treat such actions and notifications as non-existing, i.e., ignore them. The first two requirements seem rather restrictive. On the other hand, the last one is difficult to guarantee - for example, things can break after an augment within the mounted schema. B.2. Tree Representation Need to decide how/if mount points are represented in trees. Bjorklund & Lhotka Expires November 17, 2017 [Page 27]
Internet-Draft YANG Schema Mount May 2017 B.3. Design-Time Mounts The document currently doesn't provide explicit support for design- time mounts. Design-time mounts have been identified as possibly for multiple cases, and it may be worthwhile to identify a minimum or complete set of modules that must be supported under a mount point. This could be used in service modules that want to allow for configuration of device-specific information. One option could be to add an extension that specify that a certain module is required to be mounted. Also, if design-time mounts are supported, it could be possible to represent both mounts points and their required modules in tree representations and support for such would need to be defined. Authors' Addresses Martin Bjorklund Tail-f Systems Email: mbj@tail-f.com Ladislav Lhotka CZ.NIC Email: lhotka@nic.cz Bjorklund & Lhotka Expires November 17, 2017 [Page 28]