INTERNET DRAFT                           Randy Turner, Sharp Labs
<draft-ietf-printmib-mib-info-04.txt>
January 22, 1999                            Expires June 22, 1999



                           Printer MIB








Status of this Memo

This document is an Internet-Draft. Internet-Drafts are working
documents of the Internet Engineering Task Force (IETF), its
areas, and its working groups. Note that other groups may also
distribute working documents as Internet-Drafts.


Internet-Drafts are draft documents valid for a maximum of six
months and may be updated, replaced, or made obsolete by other
documents at any time. It is inappropriate to use Internet-Drafts
as reference material or to cite them other than as "work in
progress."


To learn the current status of any Internet-Draft, please check
the "1id-abstracts-txt" listing contained in the Internet-Drafts
Shadow Directories on ftp.is.co.za (Africa), nic.nordu.net
(Europe), munnari.oz.au (Pacific Rim), ftp.ietf.org (US East
Coast), or ftp.isi.edu (US West Coast).

Abstract

This document provides definitions of models and manageable
objects for printing environments. The objects included in this
MIB apply to physical, as well as logical entities within a
printing device. This MIB definition makes explicit references to
the Host Resources MIB (RFC 1514), as well as the Interfaces
Group of MIB-II (RFC 1213).









Turner                   Printer MIB V2                  [Page 1]


INTERNET DRAFT          Printer MIB              January 22, 1999



Table of Contents


1.  Introduction................................................8


1.1  Network Printing Environment...............................8


1.2  Printer Device Overview....................................9


1.3  Categories of Printer Information.........................10


1.3.1  Descriptions............................................10


1.3.2  Status..................................................10


1.3.3  Alerts..................................................10


2.  Printer Model..............................................11


2.1  Overview of the Printer Model.............................12


2.2  Printer Sub-Units.........................................13


2.2.1  General Printer.........................................13


2.2.1.1 International Considerations...........................13


2.2.2  Inputs..................................................14


2.2.3  Media...................................................14


2.2.4  Outputs.................................................15




Turner                 Printer MIB V2                    [Page 2]


INTERNET DRAFT          Printer MIB              January 22, 1999



2.2.5  Finishers...............................................15


2.2.6  Markers.................................................16


2.2.7  Media Paths.............................................16


2.2.8  System Controller.......................................17


2.2.9  Interfaces..............................................17


2.2.10  Print Job Delivery Channels............................17


2.2.11  Interpreters...........................................18


2.2.12  Console................................................18


2.2.13  Alerts.................................................18


2.2.13.1  Status and Alerts....................................19


2.2.13.2  Overall Printer Status...............................19


2.2.13.2.1  Host Resources MIB Printer Status..................21


2.2.13.2.2  Sub-unit Status....................................23


2.2.13.3  Alert Tables.........................................24


2.2.13.4  Alert Table Management...............................25


2.3  Read-Write Objects........................................27




Turner                 Printer MIB V2                    [Page 3]


INTERNET DRAFT          Printer MIB              January 22, 1999



2.4  Enumerations..............................................28


2.4.1  Registering Additional Enumerated Values................28


3.  Groups from other MIB Specifications.......................30


3.1  System Group..............................................30


3.2  System Controller.........................................30


3.3  Interface Group objects...................................30


3.3.1  Interface Types.........................................30


3.4  Implications involved with using external MIB groups......31


3.4.1  Host Resource MIB Device Group..........................32


3.4.2  Host Resource Storage Group.............................33


3.4.3  MIB-II Interface Group..................................33


-- Textual conventions for this MIB module.....................34


-- The General Printer Group...................................64


-- The Responsible Party group.................................67


-- The Auxiliary Sheet Group...................................71


-- Administrative section......................................72




Turner                 Printer MIB V2                    [Page 4]


INTERNET DRAFT          Printer MIB              January 22, 1999



-- General alert table section.................................73


-- The Cover Table.............................................73


-- The Localization Table......................................74


-- The System Resources Tables.................................76


-- The Input Group.............................................78


-- The Extended Input Group....................................84


-- The Input Media Group.......................................85


-- The Input Switching Group...................................87


-- The Output Group............................................89


-- The Extended Output Group...................................92


-- The Output Dimensions Group.................................93


-- The Output Features Group...................................95


-- The Marker Group............................................96


-- The Marker Supplies Group..................................101


-- The Marker Colorant Group..................................104


-- The Media Path Group.......................................107




Turner                 Printer MIB V2                    [Page 5]


INTERNET DRAFT          Printer MIB              January 22, 1999



-- The Print Job Delivery Channel Group.......................110


-- The Interpreter Group......................................117


-- The Console Group..........................................121


-- The Console Light Table....................................123


-- The Alerts Group...........................................125


-- Conformance Information....................................130


Appendix A - Glossary of Terms................................142


Appendix B - Media Size Names from ISO/IEC 10175 Document
Printing Architecture.........................................146


Appendix C - Media Names......................................149


Appendix D - Roles of Users...................................154


Appendix E - Overall Printer Status Table.....................158


Appendix F - Participants.....................................166


Security Considerations.......................................166


Copyright.....................................................167


References....................................................168


Authors' Addresses............................................168



Turner                 Printer MIB V2                    [Page 6]


INTERNET DRAFT          Printer MIB              January 22, 1999





















































Turner                 Printer MIB V2                    [Page 7]


INTERNET DRAFT          Printer MIB              January 22, 1999




1.  Introduction


1.1  Network Printing Environment

The management of producing a printed document, in any computer
environment, is a complex subject. Basically, the task can be
divided into two overlapping pieces, the management of printing
and the  management of the printer. Printing encompasses the
entire process of producing a printed document from generation of
the file to be printed, selection of a printer, choosing printing
properties , routing, queuing, resource management, scheduling,
and final printing including notifying the user.  Most of the
printing process is outside the scope of the model presented
here; only the management of the printer is covered.


































Turner                 Printer MIB V2                    [Page 8]


INTERNET DRAFT          Printer MIB              January 22, 1999



        Figure 1 - One Printer's View of the Network


    system   printer    asset     user        user         user
    manager  operator   manager
      O         O         O         O           O            O
     /|\       /|\       /|\       /|\         /|\          /|\
     / \       / \       / \       / \         / \          / \
      |         |         |         |           |            |
+---------+ +-------+ +-------+ +-------+ +---------+ +---------+
|configur-| |printer| | asset | |printer| |   user  | |  user   |
|ator     | |manager| |manager| |browser| |applica- | |applica- |
|         | |       | |       | |       | | tion    | | tion    |
+---------+ +-------+ +-------+ +-------+ +---------+ +---------+
   ^            ^         ^         ^           |           |
   |R/W         |R/W      |R        |R    +---------+ +---------+
   |            |         |         |     | spooler | | spooler |
   |            |         |         |     +---------+ +---------+
   |            |         |         |           |         |
   |            |         |         |     +---------+ +---------+
   |            |         |         |     |supervi- | |supervi- |
   |            |         |         |     |   sor   | |   sor   |
   |            |         |         |     +---------+ +---------+
   |            |         |         |      ^     ^     ^     ^
   v            v         |         |      |R    |R/W  |R    |R/W
================================================ |   =====   |
                     |SNMP                  print|      print|
  +-----+        +-------+                   data|       data|
  | MIB |<------>| agent |                    PCL|        PCL|
  +-----+        +-------+             PostScript| PostScript|
                     |unspecified            NPAP|       NPAP|
  +=============+  +------------------+      etc.|       etc.|
  |             |--|channel/interface |<---------+           |
  |             |  +------------------+                      |
  |   PRINTER   |                                            |
  |             |  +------------------+                      |
  |             |--|channel/interface |<---------------------+
  +=============+  +------------------+


1.2  Printer Device Overview

A printer is the physical device that takes media from an input
source, produces marks on that media according to some page
description or page control language and puts the result in some
output destination, possibly with finishing applied. Printers are
complex devices that consume supplies, produce waste and have
mechanical problems. In the management of the physical printing


Turner                 Printer MIB V2                    [Page 9]


INTERNET DRAFT          Printer MIB              January 22, 1999



device the description, status and alert information concerning
the printer and its various subparts has to be made available to
the management application so that it can be reported to the end
user, key operators for the replenishment of supplies or the
repair or maintenance of the device. The information needed in
the management of the physical printer and the management of a
printing job overlap highly and many of the tasks in each
management area require the same or similar information.


1.3  Categories of Printer Information

Information about printers is classified into three basic
categories: descriptions, status and alerts.


1.3.1  Descriptions

Descriptions convey information about the configuration and
capabilities of the printer and its various sub-units. This
information is largely static information and does not generally
change during the operation of the system but may change as the
printer is repaired, reconfigured or upgraded. The descriptions
are one part of the visible state of the printer where state
means the condition of being of the printer at any point in time.


1.3.2  Status

Status is the information regarding the current operating state
of the printer and its various sub-units. Status is the rest of
the visible state of the printer. As an example of the use of
status, a management application must be able to determine if the
various sub-units are ready to print or are in some state that
prevents printing or may prevent printing in the future.


1.3.3  Alerts

An Alert is the representation of a reportable event in the
printer. An event is a change in the state of the printer. Some
of those state changes are of interest to a management
application and are therefore reportable. Typically, these are
the events that affect the printer's ability to print. Alerts
usually occur asynchronously to the operation of the computer
system(s) to which the printer is attached. For convenience
below, "alert" will be used for both the event caused by a change
in the printer's state and for the representation of that event.


Turner                 Printer MIB V2                   [Page 10]


INTERNET DRAFT          Printer MIB              January 22, 1999



Alerts can be classified into two basic categories, critical and
non-critical.  A critical alert is one that is triggered by entry
into a state in which the printer is stopped and printing can not
continue until the condition that caused the critical alert is
eliminated. "Out of paper", "toner empty" and "output bin full"
are examples of critical alerts. Non-critical alerts are
triggered by those events that enter a state in which printing is
not stopped. Such a non-critical state may, at some future time,
lead to a state in which printing may be stopped.  Examples of
this kind of non-critical alerts are "input media low", "toner
low" and "output bin nearly full". Or, a non-critical alert may
simply provide information, such as signaling a configuration
changed in the printer.

Description, status and alert information about the printer can
be thought of as a data base describing the printer. The
management application for a printer will want to view the
printer data base differently depending on how and for what
purposes the information in the data base is needed.


2.  Printer Model

In order to accomplish the management of the printer, an abstract
model of the printer is needed to represent the sub-units from
which the printer is composed. A printer can be described as
consisting of 13 types of sub-units. It is important to note that
the sub-units of a printer do not necessarily relate directly to
any physically identifiable mechanism. Sub-units can also be a
set of definable logical processes, such as interpreters for page
description languages or command processors that set various
operating modes of the printer.

Figure 2 shows a block diagram of the printer and its basic 13
sub-units.















Turner                 Printer MIB V2                   [Page 11]


INTERNET DRAFT          Printer MIB              January 22, 1999



                Figure 2 - Printer  Block Diagram

                           Physical Connections
                                   |
                            +-------------+
                            | Interface   |
                            | (RFC1213)   |
                            +-------------+
                                   |
                            +-------------+      +-----------+
                            | Channel     |      | Operator  |
                            |             |      |  Console  |
                            +-------------+      +-----------+
                                   |
        +-----------+       +-------------+      +-----------+
        |  General  |       | Interpreter |      |  Alerts   |
        |  Printer  |       |             |      |           |
        +-----------+       +-------------+      +-----------+
                                   |
                   +-------------------------------+
                   |        System Controller      |
                   |     (Host Resources MIB)      |
                   +-------------------------------+

+------+   +---------+    +---------+   +-------+   +--------+
|Input |   |         |    |  Marker |   |       |   | Output |
|      |==>|         |+<=>|         |<=>|       |+=>|        |
+------+   +---+  +--+    +---------+   +--+ +--+   +--------+
     \         |  |                        | |           \
+----------+   |  |                        | |     +----------+
| Media    |   |  +------------------------+ |     | Finisher |
|          |   |        Media Path           |     |          |
|(optional)|   +-----------------------------+     |(optional)|
+----------+                                       +----------+


2.1  Overview of the Printer Model

The model has three basic parts: (1) the flow of a print file
into an interpreter and onto the marker, (2) the flow of media
through the marker and (3) the auxiliary sub-units that control
and facilitate the two prior flows.  The flow of the print data
comes through a physical connection on which some form of
transport protocol stack is running.  The data provided by the
transport protocol (interface) appears on a channel which is the
input to an interpreter. The interpreter converts the print data
into a form suitable for marking on the media.



Turner                 Printer MIB V2                   [Page 12]


INTERNET DRAFT          Printer MIB              January 22, 1999



The media resides in Input sub-units from which the media is
selected and then transported via a Media Path first to a Marking
sub-unit and then onto an Output sub-unit with (optionally) some
finishing operations being performed.  The auxiliary sub-units
facilitate control of the printer, inquiry/control of the
operator panel, reporting of alerts, and the adaptation of the
printer to various natural languages and characters sets. All the
software sub-units run on the System Controller which represents
the processor, memory and storage systems of the Printer.  Each
of the sub-units is discussed in more detail below.

All of the sub-units other than the Alerts report only state
information, either a description or a status. The Alerts sub-
unit reports event information.


2.2  Printer Sub-Units

A printer is composed of 13 types of sub-units, called groups.
The following sections describe the different types of sub-units.


2.2.1  General Printer

The general printer sub-unit is responsible for the overall
control and status of the printer. There is exactly one general
printer sub-unit in a printer. The general printer sub-unit is
represented by the General Printer Group in the model. In
addition to the providing the status of the whole printer and
allowing the printer to be reset, this Group provides information
on the status of the packaging of the printer, in particular, the
covers. The general printer sub-unit is usually implemented on
the system controller.


2.2.1.1 International Considerations

The localization portion of the general printer sub-unit is
responsible for identifying the natural language, country, and
character set in which character strings are expressed. There may
be one or more localizations supported per printer. The available
localizations are represented by the Localization table.

Localization is only performed on those strings in the MIB that
are explicitly marked as being localized.

The agent SHALL return all other character strings as coded
character sets in which code positions 0-127 (decimal) are US-


Turner                 Printer MIB V2                   [Page 13]


INTERNET DRAFT          Printer MIB              January 22, 1999



ASCII [US-ASCII]. Use of the remaining values, 128-255, is
discouraged because there is no method defined in the MIB to
determine the desired code position to character mapping and in
the future, these code positions may be used for a specific
encoding which would result in an agent utilizing these code
positions being incompatible with future implementations. Control
codes (code positions 0-31 and 127) SHALL NOT be used unless
specifically specified in the DESCRIPTION of the object.

The character set portion of the general printer sub-unit is
responsible for identifying the possible character sets that are
used by the interpreters, the operator console, and in network
management requests for display objects. There may be one or more
character sets per printer.  The understood character sets are
represented by the Character Set Table.


2.2.2  Inputs

Input sub-units are mechanisms that feed media to be marked on
into the printer. A printer contains one or more input sub-units.
These are represented by the Input Group in the model. The model
does not distinguish fixed input bins from removable trays,
except to report when a removable tray has been removed.

There are as many input sub-units as there are distinctly
selectable input "addresses".  For example, if a tray has an
option for manually feeding paper as well as automatically
feeding from the tray, then this is two input sub-units if these
two sources can be (must be) separately selected and is one input
sub-unit if putting a sheet in the manual feed slot overrides
feeding from the contents of the tray; that is, in the second
case there is no way to separately select or address the manual
feed slot.


2.2.3  Media

An input sub-unit can hold one or more instances of the media on
which marking is to be done. Typically, there is a large set of
possible media that can be associated with an input. The Media
Group is an extension of the Input Group which represents that
media that is in an input sub-unit. The Media Group only
describes the current contents of each input and not the possible
content of the input sub-unit.





Turner                 Printer MIB V2                   [Page 14]


INTERNET DRAFT          Printer MIB              January 22, 1999



2.2.4  Outputs

Output sub-units are mechanisms that receive media that has been
marked on. A printer contains one or more output mechanisms.
These are represented by the Output Group in the model. The model
does not distinguish fixed output bins from removable output
bins, except to report when a removable bin has been removed.

There are as many output sub-units as there are distinctly
selectable output "addresses".  Output sub-units can be addressed
in two different ways: (1) as a set of "mailboxes" which are
addressed by a specific mailbox selector such as a bin number or
a bin name, or (2) as a set of "slots" into which multiple copies
are collated. Sometimes both modes of using the output sub-units
can be used on the same printer.  All that is important from the
viewpoint of the model is that the output units can be separately
selected.


2.2.5  Finishers

A finisher is a sub-unit that performs some operations on the
media other than marking.  The finisher sub-units are represented
by the Finisher Group in the model.  Some examples of finishing
processes are stapling, punching, binding, inserting, or folding.
Finishing processes may have supplies associated with the
process.  Stapling, binding, and punching are examples of
processes that have supplies. A printer may have more than one
finishing sub-unit and each finishing sub-unit may be associated
with one or more output sub-units. Finishers are not described in
this MIB.

The exact interaction and sequencing between an output device and
its associated finisher is not specified by the model. It depends
on the type of finishing process and the exact implementation of
the printer system. This standard allows for the logical
association of a finishing process with an output device but does
not put any restrictions on the exact sequence or interaction
with the associated output device. The output and finisher sub-
units may or may not be separate identifiable physical mechanisms
depending on the exact implementation of a printer.  In addition,
a single output device may be associated with multiple finishing
sub-units and a single finishing sub-unit may be associated with
multiple output devices.






Turner                 Printer MIB V2                   [Page 15]


INTERNET DRAFT          Printer MIB              January 22, 1999



2.2.6  Markers

A marker is the mechanism that produces marks on the print media.
The marker sub-units and their associated supplies are
represented by the Marker Group in the model. A printer can
contain one or more marking mechanisms.  Some examples of
multiple marker sub-units are: a printer with separate markers
for normal and magnetic ink or an imagesetter that can output to
both a proofing device and final film. Each marking device can
have its own set of  characteristics associated with it, such as
marking technology and resolution.

In this model the marker sub-unit is viewed as very generalized
and encompasses all aspects of a marking process. For example, in
a xerographic process, the marking process as well as the fusing
process would be included in the generalized concept of the
marker. With the generalized concept of a marking process, the
concept of multiple marking supplies associated with a single
marking sub-unit results. For example, in the xerographic
process, there is not only a supply of toner, but there can also
be other supplies such as a fuser supply (e.g., fuser oil) that
can be consumed and replaced separately. In addition there can be
multiple supplies of toner for a single marker device, as in a
color process.


2.2.7  Media Paths

The media paths encompass the mechanisms in the printer that move
the media through the printer and connect all other media related
sub-units: inputs, outputs, markers and finishers. A printer
contains one or more media paths. These are represented by the
Media Path Group in the model.  The Media Path group has some
objects that apply to all paths plus a table of the separate
media paths.

In general, the design of the media paths determines the maximum
speed of the printer as well as the maximum media size that the
printer can handle. Media paths are complex mechanisms and can
contain many different identifiable sub-mechanisms such as media
movement devices, media buffers, duplex units and interlocks. Not
all of the various sub-mechanisms reside on every media path.
For example, one media path may provide printing only on one
surface of the media (a simplex path) and another media path may
have a sub-mechanism that turns the media over and feeds it a
second time through the marker sub-unit (a duplex path).  The
duplex path may even have a buffer sub-mechanism that allows



Turner                 Printer MIB V2                   [Page 16]


INTERNET DRAFT          Printer MIB              January 22, 1999



multiple copies of the obverse side to be held before the reverse
side of all the copies are marked.


2.2.8  System Controller

The System Controller is the sub-unit upon which the software
components of the Printer run. The System Controller is
represented in the model by the Host Resources MIB. This MIB
allows for the specification of the processor(s), memory, disk
storage, file system and other underlying sub-mechanisms of the
printer. The controller can range from simple single processor
systems to multiprocessor systems. In addition, controllers can
have a full range of resources such as hard disks. The printer is
modeled to have one system controller even though it may have
more than one processor and multiple other resources associated
with it.


2.2.9  Interfaces

An interface is the communications port and associated protocols
that are responsible for the transport of data to the printer. A
printer has one or more interface sub-units. The interfaces are
represented by the Interfaces Group of MIB-II (RFC 1213). Some
examples of interfaces are serial ports (with little or no
protocol) and Ethernet ports on which one might run InterNet IP,
Novell IPX, etc.


2.2.10  Print Job Delivery Channels

The print job delivery channel sub-units identify the independent
sources of print data (here print data is the information that is
used to construct printed pages and may have both data and
control aspects).  A printer may have one or more channels. The
channel sub-units are represented by the Print Job Delivery
Channel Group in the Model. Each channel is typically identified
by the electronic path and service protocol used to deliver print
data to the printer. A channel sub-unit may be independently
enabled (allowing print data to flow) or disabled (stopping the
flow of print data). It has a current Control Language which can
be used to specify which interpreter is to be used for the print
data and to query and change environment variables used by the
interpreters (and SNMP). There is also a default interpreter that
is to be used if an interpreter is not explicitly specified using
the Control Language. Print Job Delivery Channel sub-units can,
and usually are, based on an underlying interface.


Turner                 Printer MIB V2                   [Page 17]


INTERNET DRAFT          Printer MIB              January 22, 1999



2.2.11  Interpreters

The interpreter sub-units are responsible for the conversion of a
description of intended print instances into images that are to
be marked on the media. A printer may have one or more
interpreters. The interpreter sub-units are represented by the
Interpreter Group in the Model. Each interpreter is generally
implemented with software running on the System Controller sub-
unit. The Interpreter Table has one entry per interpreter where
the interpreters include both Page Description Language (PDL)
Interpreters and Control Language Interpreters.


2.2.12  Console

Many printers have a console on the printer, the operator
console, that is used to display and modify the state of the
printer.  The console can be as simple as a few indicators and
switches or as complicated as full screen displays and keyboards.
There can be at most one such console.  This console sub-unit is
represented by the Console Group in the model.  Although most of
the information displayed there is also available in the state of
the printer as represented by the various Groups, it is useful to
be able to query and modify the operator console remotely.  For
example, a management application might like to display to its
user the current message on the operator console of the remote
printer or the management application user might like to modify
the current message on the operators console of the remote
printer.  As another example, one might have a remote application
that puts up a pseudo console on a workstation screen. Since the
rules by which the printer state is mapped onto the console and
vice versa are not standardized, it is not possible to reproduce
the console state or the action of console buttons and menus.
Therefore, the Console Group provides access to the console. The
operator console is usually implemented on the system controller
with additional hardware for input and display.


2.2.13  Alerts

The alert sub-unit is responsible for detecting reportable
events, making an entry in the alert table and, if and only if
the event is a critical event, initiating a trap. The exception
to this rule is when the "alertRemovalofBinaryChangeEntry" trap
is generated. The alert sub-unit is represented by the Alerts
Group and, in particular, the Alert Table. This table contains
information on the severity, sub-unit, detailed location within
the sub-unit, alert code and description of each critical alert


Turner                 Printer MIB V2                   [Page 18]


INTERNET DRAFT          Printer MIB              January 22, 1999



that is currently active within the printer. Each reportable
event causes an entry to be made in the Alert Table.


2.2.13.1  Status and Alerts

Summary information about the state of the printer is reported at
three separate levels: (1) there is the status of the printer as
a whole reported in the Host Resources MIB, (2) there is the
status of various sub-units reported in the principle table of
the Group that represents the sub-unit, and (3) there are alert
codes reported in the Alert Table.


2.2.13.2  Overall Printer Status

Of the many states a printer can be in, certain states are more
"interesting" because of the distinct actions they are likely to
provoke in the administrator.  These states may be applied to the
printer as a whole, or to a particular sub-unit of the printer.
These named states are:

Non Critical Alert Active - For the printer this means that one
or more sub-units have a non-critical alert active.  For a sub-
unit, this means that the sub-unit has a non-critical alert
active.

Critical Alert Active - For the printer this means that one or
more sub-units have a critical alert active.  For a sub-unit,
this means that the sub-unit has a critical alert active.

Unavailable - The printer or sub-unit is unavailable for use
(this is the same as "broken" or "down" in other terminology).  A
trained service person is typically necessary to make it
available.

Moving on-line or off-line - The printer is either off-line, in
the process of moving off-line or in the process of moving back
on-line; for example on high end printers reloading paper
involves a transition to off-line to open the paper bin, it is
then filled and, finally, there is a transition back to on-line
as the paper bin is repositioned for printing.

Standby - The printer or sub-unit is not immediately available
but can accept new instructions.

Available - The printer or subunit is functioning normally.



Turner                 Printer MIB V2                   [Page 19]


INTERNET DRAFT          Printer MIB              January 22, 1999



Idle - The printer or subunit is immediately available.

Active - The printer or subunit is performing its primary
function.

Busy - The printer or subunit is performing a function (not
necessarily its primary function) and is not immediately
available for its primary function.

The Host Resources MIB (RFC 1514) provides three status objects
that can be used to describe the status of a printer: (1)
hrDeviceStatus in the entry in the hrDeviceTable; (2)
hrPrinterStatus in the hrPrinterTable; and (3)
hrPrinterDetectedErrorState in the hrPrinterTable.  These objects
describe many of the states that a printer can be in.  The
following table shows how the states named above can be
recognized by inspecting the values of the three printer-related
objects in the Host Resources MIB:

Printer       hrDeviceStatus hrPrinterStatus hrPrinterDetected-
Status                                       ErrorState

Idle           running(2)     idle(3)        none set

Busy/          running(2)     printing(4)
Active

Non Critical   warning(3)     idle(3) or     could be: lowPaper,
Alert Active                  printing(4)    lowToner, or
                                             serviceRequested

Critical       down(5)        other(1)       could be: jammed,
Alert Active                                 noPaper, noToner,
                                             coverOpen, or
                                             serviceRequested

Unavailable    down(5)        other(1)

Moving off-    warning(3)     idle(3) or     offline
line                          printing(4)
Off-line       down(5)        other(1)       offline

Moving         down(5)        warmup(5)
on-line

Standby        running(2)     other(1)




Turner                 Printer MIB V2                   [Page 20]


INTERNET DRAFT          Printer MIB              January 22, 1999



These named states are only a subset of the possible states -
they are not an exhaustive list of the possible states.
Nevertheless, several things should be noted.  When using these
states, it is not possible to detect when both critical and non-
critical alerts are pending - if both are pending, the Critical
Alert Active state will prevail.  In addition, a printer in the
Standby state will be represented in the Host Resources MIB with
a device status of running(2) and a printer status of other(1), a
set of states that don't uniquely distinguish this important
printer state.

Although the above mapping is workable, it would be improved with
a few additions to hrDeviceStatus and hrPrinterStatus in the Host
Resources MIB. In particular, it would be appropriate to add a
"standby" enumeration to hrDeviceStatus.  Similarly, it would be
useful to add the following states to hrPrinterStatus: "offline"
to indicate that reason for the printer being down (instead of
having to use "other") which allows both "warning" and "offline"
to indicate going offline and "down" and "offline" to indicate
offline and "notApplicable" to cover cases, such as "standby",
where the device state completely describes the state of the
device. The suggestions and additions discussed above would
require re-convening of the Host Resources MIB working group and
a new draft issued prior to actual implementation of these
suggestions and/or additions.

Detailed status per sub-unit is reported in the sub-unit status
fields.


2.2.13.2.1  Host Resources MIB Printer Status

For completeness, the definitions of the Printer Status objects
of the Host Resources MIB are given below:

hrDeviceStatus OBJECT-TYPE
     SYNTAX  INTEGER {
                unknown(1),
                running(2),
                warning(3),
                testing(4),
                down(5)
           }
     ACCESS  read-only
     STATUS  mandatory
     DESCRIPTION
         "The current operational state of the device
         described by this row of the table.  A value


Turner                 Printer MIB V2                   [Page 21]


INTERNET DRAFT          Printer MIB              January 22, 1999



         unknown(1) indicates that the current state of the
         device is unknown.  running(2) indicates that the
         device is up and running and that no unusual error
         conditions are known.  The warning(3) state
         indicates that agent has been informed of an
         unusual error condition by the operational software
         (e.g., a disk device driver) but that the device
         is still 'operational'.  An example would be high
         number of soft errors on a disk.  A value of
         testing(4), indicates that the device is not
         available for use because it is in the testing
         state.  The state of down(5) is used only when
         the agent has been informed that the device is
         not available for any use."
     ::= { hrDeviceEntry 5 }

   hrPrinterStatus OBJECT-TYPE
          SYNTAX INTEGER {
              other(1),
              unknown(2),
              idle(3),
              printing(4),
              warmup(5)
          }
          ACCESS read-only
          STATUS mandatory
          DESCRIPTION
              "The current status of this printer device.  When
              in the idle(3), printing(4), or warmup(5) state,
              the corresponding hrDeviceStatus should be
              running(2) or warning(3).  When in the unknown(2)
              state, the corresponding hrDeviceStatus should be
              unknown(1)."
          ::= { hrPrinterEntry 1 }

      hrPrinterDetectedErrorState OBJECT-TYPE
          SYNTAX BITS (0..128)
          ACCESS read-only
          STATUS mandatory
          DESCRIPTION
              "This object represents any error conditions
              detected by the printer.  The error conditions are
              encoded as an OCTET STRING with the following
              definitions:

              Condition           Bit #    hrDeviceStatus
              lowPaper            0        warning(3) or down(5)
              noPaper             1        warning(3) or down(5)


Turner                 Printer MIB V2                   [Page 22]


INTERNET DRAFT          Printer MIB              January 22, 1999



              lowToner            2        warning(3) or down(5)
              noToner             3        warning(3) or down(5)
              coverOpen           4        warning(3) or down(5)
              jammed              5        warning(3) or down(5)
              offline             6        warning(3) or down(5)
              serviceRequested    7        warning(3) or down(5)

              inputTrayMissing    8        warning(3) or down(5)
              outputTrayMissing   9        warning(3) or down(5)
              markerSupplyMissing 10       warning(3) or down(5)
              outputNearFull      11       warning(3) or down(5)
              outputFull          12       warning(3) or down(5)
              inputTrayEmpty      13       warning(3) or down(5)
              overduePreventMaint 14       warning(3) or down(5)


              If multiple conditions are currently detected and
              the hrDeviceStatus would not otherwise be
              unknown(1) or testing(4), the hrDeviceStatus shall
              correspond to the worst state of those indicated,
              where down(5) is worse than warning(3) which is
              worse than running(2).


              Bits are numbered starting with the most
              significant bit of the first byte being bit 0, the
              least significant bit of the first byte being bit
              7, the most significant bit of the second byte
              being bit 8, and so on.  A one bit encodes that the
              condition was detected, while a zero bit encodes
              that the condition was not detected.

              This object is useful for alerting an operator to
              specific warning or error conditions that may
              occur, especially those requiring human
              intervention."
          ::= { hrPrinterEntry 2 }


2.2.13.2.2  Sub-unit Status

Sub-unit status is reported in the entries of the principle table
in the Group that represents the sub-unit. For sub-units that
report a status, there is a status column in the table and the
value of this column is always an integer formed in the following
way




Turner                 Printer MIB V2                   [Page 23]


INTERNET DRAFT          Printer MIB              January 22, 1999



The SubUnitStatus is an integer that is the sum of 5 distinct
values, Availability, Non-Critical, Critical, On-line, and
Transitioning. These values are:


     Availability                           value

            Available and Idle              0       000'b
            Available and Standby           2       010'b
            Available and Active            4       100'b
            Available and Busy              6       110'b
            Unavailable and OnRequest       1       001'b
            Unavailable because Broken      3       011'b
            Unknown                         5       101'b

    Non-Critical

            No Non-Critical Alerts          0
            Non-Critical Alerts             8

    Critical

            No Critical Alerts              0
            Critical Alerts                 16

    On-Line

            State is On-Line                0
            State is Off-Line              32

    Transitioning

            Currently at intended state     0
            Transitioning to intended state 64

For example, an input (tray) that jammed on the next to the last
page may show a status of 27 (unavailable because broken (3) + a
critical state (16), jammed, and a noncritical state (8), low
paper).


2.2.13.3  Alert Tables

The Alert Group consists of a single table in which all active
alerts are represented.  This section provides an overview of the
table and a description of how it is managed.  The basic content
of the alert table is the severity (critical or non-critical) of
the alert, the Group and entry where a state change caused the


Turner                 Printer MIB V2                   [Page 24]


INTERNET DRAFT          Printer MIB              January 22, 1999



alert, additional information about the alert (a more detailed
location, an alert code, and a description), and an indication of
the level of training needed to service the alert.

The Alert Table contains some information that is redundant, for
example that an event has occurred, and some information that is
only represented in the Alert Table, for example the additional
information.  A single table was used because a single entry in a
group could cause more than one alert, for example paper jams in
more than one place in a media path. Associating the additional
information with the entry in the affected group would only allow
one report where associating the additional information with the
alert makes multiple reports possible. Every time an alert occurs
in the printer, the printer makes one or more entries into the
Alert Table. The printer determines if an event is to be
classified as critical or non-critical. If the severity of the
Alert is "critical", the printer sends a trap or event
notification to the host indicating that the table has changed.
Whether or not a trap is sent, the management application is
expected to poll the printer on a regular basis and to read and
parse the table to determine what conditions have changed, in
order to provide reliable information to the management
application user.


2.2.13.4  Alert Table Management

The alert tables are sparsely populated tables. This means the
tables will only contain entries of the alerts that are currently
active and the number of rows, or entries in the table will be
dynamic. More than one event can be added or removed from the
event tables at a time depending on the implementation of the
printer.

There are basically two kinds of events that produce alerts:
binary change events and unary change events. Binary change
events come in pairs: the leading edge event and the trailing
edge event. The leading edge event enters a state from which
there is only one exit; for example, going from running to
stopped with a paper jam. The only exit from this state is fixing
the paper jam and it is clear when that is accomplished.  The
trailing edge event is the event which exits the state that was
entered by the leading edge event; in the example above fixing
the paper jam is the trailing edge event.

It is relatively straightforward to manage binary change events
in the Alert Table. Only the leading edge event makes an entry in
the alert table.  This entry persists in the Alert Table until


Turner                 Printer MIB V2                   [Page 25]


INTERNET DRAFT          Printer MIB              January 22, 1999



the trailing edge event occurs at which point this event is
signaled by the removal of the leading edge event entry in the
Alert Table.  That is, a trailing edge event does not create an
entry; it removes the corresponding leading edge event. Removing
the leading edge entry may cause the unary change event
"alertRemovalofBinaryChangeEntry" to be added to the table.  With
binary change events it is possible to compute the maximum number
that can occur at the same time and construct an Alert Table that
would hold that many events. There would be no possibility of
table overflow and no information about outstanding events would
be lost.

Unfortunately, there are some events that are not binary changes.
This other category of event, the unary change event, is
illustrated by the configuration change event. With this kind of
event the state of the machine has changed, but to a state which
is (often) just as valid as the state that was left and from
which no return is necessary.  For example, an operator may
change the paper that is in the primary input source from letter
to legal. At some time in the future the paper may be changed
back to letter, but it might be changed to executive instead.
This is where the problem occurs. It is not obvious how long to
keep unary change event entries in the Alert Table. If they were
never removed, the Alert Table would continue to grow
indefinitely.

The agent needs to have an algorithm implemented for the
management of the alert table, especially in the face of
combinations of binary and unary alerts that would overflow the
storage capacity of the table.  When the table is full and a new
alert needs to be added, an old alert needs to be deleted.  The
alert to be deleted should be chosen using the following rules:


1. Find a non-critical unary alert and delete it.  If there
are multiple non-critical unary alerts, it is suggested that the
oldest one be chosen.  If there are no non-critical unary
alerts, then,

2. Find a non-critical binary alert and delete it.  If there are
multiple non-critical binary alerts, it is suggested that the
oldest one be chosen.  If there are no non-critical binary
alerts, then,

3. Find a critical (binary) alert and delete it.  If there are
multiple critical alerts, it is suggested that the oldest one be
chosen.  Agent implementers are encouraged to provide at least
enough storage space for the maximum number of critical alerts


Turner                 Printer MIB V2                   [Page 26]


INTERNET DRAFT          Printer MIB              January 22, 1999



that could occur simultaneously.  Note that all critical alerts
are binary.

In the event that a critical binary alert must be managed out of
the alert table; when space allows and the alert condition still
exists, the alert must be re-added to the alert table even if
there was no subsequent transition into the associated state. It
is recommended that this be done for non-critical binary alerts
as well. Note that the new alert entry will not have the same
index as the original entry that was moved out of the table.

Note that because the Alert Index is a monotonically increasing
integer there will be gaps in the values in the table when an
alert is deleted.  Such gaps can be detected by the management
application to indicate that the management application may want
to re-acquire the Printer state and check for state changes it
did not observe in the Alert Table.


2.3  Read-Write Objects

Some of the objects in the printer MIB report on the existence of
or amount of a given resource used with the printer.  Some
examples of such resources are the size and number of sheets of
paper in a paper tray or the existence of certain output options.
On some printers there are sensors that allow these resources to
be sensed.  Other printers, however, lack sensors that can detect
(all of) the properties of the resource.  Because the printer
needs to know of the existence or properties of these resources
for the printer to function properly some other way of providing
this information is needed.  The chosen way to solve this problem
is to allow a management application to write into objects which
hold the descriptive or existence values for printers that cannot
sense the values.  Thus many of the objects in the MIB are given
read-write access, but a printer implementation might only permit
a management operation to change the value if the printer could
not sense the value itself.  Therefore, the ability to change the
value of a read-write object may depend on the implementation of
the agent.  Note that even though some objects explicitly state
the behavior of conditional ability to change values, any read-
write object may act that way.

Generally, an object is given read-write access in the Printer
MIB specification if:

1. The object involves installation of a resource that some
printers cannot themselves detect.  Therefore, external means are
needed to inform the printer of the installation.  (Here external


Turner                 Printer MIB V2                   [Page 27]


INTERNET DRAFT          Printer MIB              January 22, 1999



means include using the operator console, or remote management
application) and

2. The printer will behave differently if the installation of the
resource is reported than the printer would if the installation
were not reported; that is, the object is not to be used as a
place to put information not used by the printer, i.e., not a
"sticky-note".  Another way of saying this is that the printer
believes that information given it and acts as if the information
were true.  For example, on a printer that cannot sense the size,
if one paper size is loaded, but another size is set into the
paper size object, then the printer will use the size that was
set as its current paper size in its imaging and paper handling.

The printer may get hints that it may not know about the
existence or properties of certain resources.  For example, a
paper tray may be removed and re-inserted.  When this removal and
insertion happens, the printer may either assume that a property,
such as the size of paper in the tray, has not changed or the
printer may change the value of the associated object to
"unknown", as might be done for the amount of paper in the tray.
As long as the printer acts according to the value in  the object
either strategy is acceptable.

It is an implementation-specific matter as to whether or not MIB
object values are persistent across power cycles or cold starts.
It is particularly important that the values of the
prtMarkerLifeCount object persist throughout the lifetime of the
printer.  Therefore, if the value of any MIB object persists
across power cycles, then the prtMarkerLifeCount object must also
persist.


2.4  Enumerations

Enumerations (enums) are sets of symbolic values defined for use
with one or more objects.  Some common enumeration sets are
assigned a symbolic data type name (textual convention).  These
enumerations are listed at the beginning of this specification.


2.4.1  Registering Additional Enumerated Values

This working group has defined several types of enumerations.
These enumerations differ in the method employed to control the
addition of new enumerations.  Throughout this document,
references to "enumeration (n)", where n can be 1, 2 or 3 can be



Turner                 Printer MIB V2                   [Page 28]


INTERNET DRAFT          Printer MIB              January 22, 1999



found in the various tables.  The definitions of these types of
enumerations are:

enumeration (1)  All the values are defined in the Printer MIB
specification (RFC for the Printer MIB).  Additional enumerated
values require a new RFC. Type 1 enumerations are typically used
where changes to the enumeration are either unlikely or will have
a significant impact on the structure of the MIB or
implementation of the MIB in management applications.

Some criteria that suggest using a type 1 enumeration are:

a) the set of values in the enumeration is thought to be known,
e.g., faceUp and faceDown

b) the enumeration defines a set of units of measure which must
be understood by a management application to be able to correctly
display the value of an object that measurement unit controls;
and

c) the enumeration is tied to the structure of the MIB or the
model on which the MIB is based, e.g., the prtAlertGroup
enumeration is tied to the OIDs for the related tables.

enumeration (2)  An initial set of values are defined in the
Printer MIB specification.  Additional enumerated values are
registered after review by this working group. The initial
versions of the MIB will contain the values registered so far.
After the MIB is approved, additional values will be registered
through IANA after approval by this working group. The current
set of approved values should always be obtained from the IANA
registry. Type 2 enumerations are typically used where it is
important to insure consistent usage of the enumeration values;
that is, to insure that the same entity does not get two
different enumerations values, or two different entities do not
get the same enum value.

enumeration (3)  An initial set of values are defined in the
Printer MIB specification.  Additional enumerated values are
registered without working group review.  The initial versions of
the MIB will contain the values registered so far.  After the MIB
is approved, additional values will be registered through IANA
without approval by this working group.  The current set of
approved values should always be obtained from the IANA registry.
Type 3 enumerations are used for enumerations that can be
extended without any controls; an example is the
prtMarkerSuppliesType, which can be extended as needed by any
manufacturer to describe the supplies required by a new printer.


Turner                 Printer MIB V2                   [Page 29]


INTERNET DRAFT          Printer MIB              January 22, 1999



3.  Groups from other MIB Specifications

This section identifies the groups from other MIBs that shall be
supported to supplement and complete a printer MIB
implementation. The section also describes some of the less
obvious characteristics of the Printer MIB structure that are
related to the inclusion of these other MIB groups




3.1  System Group

All objects in the system group of MIB-II (RFC 1213) shall be
implemented; however, as described in paragraph 3.4, implementers
should carefully consider what constitutes the "system".


3.2  System Controller

The storage and device groups of the Host Resources MIB (RFC
1514) shall be implemented to support the printer(s) system
controller, and any supporting devices. If deemed appropriate by
the implementer, other groups of the Host Resources MIB (System,
Running Software, Running Software Performance, and Installed
Software) may be implemented.

Because of the structure of the Host Resources MIB, the devices
constituting the system controller are at the same level as the
printer.


3.3  Interface Group objects

All objects in the Interfaces Group of MIB-II (RFC 1213) shall be
implemented for all print information interfaces to the printer,
including non-network interfaces.


3.3.1  Interface Types

The interfaces group of RFC 1213 contains only a partial list of
interface types that can be specified in the "ifType" object. For
a complete list of interface types, refer to the IANA registry at
"ftp://ftp.isi.edu/mib/ianaiftype.mib"





Turner                 Printer MIB V2                   [Page 30]


INTERNET DRAFT          Printer MIB              January 22, 1999



3.4  Implications involved with using external MIB groups

In structuring the Printer MIB, it is inconvenient to follow the
hierarchical structure implicit in the printer block diagram.
There are two reasons for this:

     1. Figure 2 suggests that the printer interface to the
network is through the interfaces group. It is generally required
that this network node is supported by an implementation of RFC
1213. However, the network node may support one printer or
several printers. Further, the SNMP agent may be within the
"system controller" (the printer controller board), or the SNMP
agent may be within a device completely external to the printer
system controller. Therefore, the relationship between the MIB-II
defined network node, the agent implementing the Printer and Host
Resources MIB, and the functional printer itself may not be
consistent with the structure suggested in figure 2.

     2. In many cases, the printer controller is a generic
computing device (PC or other standalone computer) containing
many of the resources of a standard host computer. This includes
devices such as memory, interfaces, network, and printer. The
Host Resources MIB has well developed structures for such
devices. However, the Host Resources MIB only deals with devices
associated with a single "host", and it considers the printer to
be a part of this host on the same level as memory, processor,
and other devices considered part of the "System Controller" of
the printer.

Therefore, it was convenient to conceive of a "host" associated
with the SNMP agent and with the network node by which the agent
and ultimately the printer(s) communicate with the network. All
host-resource devices communicating through this network node are
considered part of the host and are supported by implementation
of the Host Resources MIB Device and Storage group.

Another aspect of printer as a device consideration is that, not
only are the printer and the host resource devices constituting
the System Controller of the printer at the same level, but if
there are multiple printers, these printers and the Host Resource
devices constituting these printers are all at the same level,
whether the devices are dedicated to one printer or shared. The
functional hierarchy implicit in the printer block diagram is
therefore flattened with respect to host resource devices.






Turner                 Printer MIB V2                   [Page 31]


INTERNET DRAFT          Printer MIB              January 22, 1999



3.4.1  Host Resource MIB Device Group

For each instance of a host resource device, the following
attributes exist:

hrDeviceIndex, hrDeviceType, hrDeviceDescr, hrDeviceID,
hrDeviceStatus, and hrDeviceErrors.

The Device Description, Device ID and Device Status listed in
this table identify and characterize a printer. The hrDevice
index for each printer is included as an indexing value for
almost all variables in the Printer MIB. In the case of multiple
printers, the printer MIB appears as a composite MIB for all
printers considered part of this "host". Each table of the
printer MIB which includes hrDeviceIndex as an index will contain
the variables for each printer.

Non-printer devices listed in the table are associated with one
or more listed printer devices by the prtDeviceRefTable in the
printer MIB. This table, as most in the printer MIB, is indexed
by hrDeviceIndex; but unlike most of the other tables where the
devices of interest are printers, the devices of interest for
this table are non-printer devices. The only accessible object
for each row in this table is the device number of the printer
device which is associated with the indexed non-printer device.
The table includes a second index, prtDevceRefSeqNumber, which
allows a listed device to be associated with multiple printer
devices.

For example, a fully integrated printer may contain, as part of
its system controller, hrDeviceProcessor, hrDeviceNetwork,
hrDeviceDiskStorage, hrDeviceParallelPort, hrDeviceSerialPort,
hrDeviceVolatileMemory and hrDeviceNonVolatileMemory.

Ideally, these must all be listed as devices in the virtual host,
along with the printer (hrDevicePrinter) itself. Therefore, in
this example, eight devices would be included with hrDeviceIndex
values of "1 - 8". Since there is but one printer, the
prtDeviceRefTable in the printer MIB would contain seven entries,
each with a value identifying the printer hrDeviceIndex. Because
there is only one printer, devices are not shared and the
prtDeviceRefSeqNumber index is (1) in all cases.

Further, the Host Resource MIB defines device specific tables to
be supported for certain devices. These devices, and the primary
significance of the additional table(s) are:




Turner                 Printer MIB V2                   [Page 32]


INTERNET DRAFT          Printer MIB              January 22, 1999



hrProcessorTable: identification and significant characteristics
of processor

hrNetworkTable: correlates a network device to a MIB-II ifIndex
key

hrPrinterTable and hrPrinterErrorTable: the mechanism
communicating the status of each printer

hrDiskStorageTable: identifies disk access, media type and
capacity

hrPartitionTable: identifies "partitions" on long term storage
devices.

hrFSTable: identifies local file system type, characteristics and
parameters.


3.4.2  Host Resource Storage Group

Program and data storage exist both as physical devices in the
Host Resource Device Table, and as logical storage areas
supported in the Host Resource Storage Group. Logical storage is
listed and assigned an index in the hrStorageTable. Storage is
correlated to specific printers by the prtStorageRefTable in the
Printer MIB. This table is indexed by hrStorageIndex. The only
accessible object for each row in this table is the device number
of the printer device which is associated with the indexed
storage. The table includes a second index,
prtStorageRefSeqNumber, which allows logical storage to be
associated with multiple printer devices.


3.4.3  MIB-II Interface Group

The interfaces by which the printer receives print data are
identified within the Interfaces table of MIB-II (RFC 1213). In
the case of multiple printers, the network interface for the
"host" as well as all of the interfaces for all printers are
listed in this table. The interfaces may also be listed as
devices in the Host Resource Device Table. Network Port devices
are identified by MIB-II "ifIndex" objects to correlate them back
to the MIB-II interface table; no such provision exists for
"serial" and "parallel" ports. Interfaces listed in the Host
Resource device table may be correlated to specific printers in
the "host" by the prtDeviceRefTable in the printer MIB; this may
be useful if there are multiple printers. The "ifIndex" is also


Turner                 Printer MIB V2                   [Page 33]


INTERNET DRAFT          Printer MIB              January 22, 1999



used to identify the interface associated with each channel in
the Printer MIB "Print Job Delivery Channel" group. Therefore,
specific interfaces are also correlated back to specific printers
via the "channels" mechanism.


Printer-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, Counter32, Integer32,
    TimeTicks, NOTIFICATION-TYPE,
    OBJECT-IDENTITY, mib-2 FROM SNMPv2-SMI
    TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC
    MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
    hrDeviceIndex, hrStorageIndex FROM HOST-RESOURCES-MIB;

printmib MODULE-IDENTITY
    LAST-UPDATED "9810070000Z"
    ORGANIZATION "IETF Printer MIB Working Group"
    CONTACT-INFO
            "Randy Turner
           Sharp Laboratories of America
           5750 NW Pacific Rim Blvd
           Camas, WA 98607
           rturner@sharplabs.com"
    DESCRIPTION
        "The MIB module for management of printers."
    ::= { mib-2 43 }

--
-- Textual conventions for this MIB module
--
--
-- Generic unspecific textual conventions
--

PrtMediaUnitTC ::= TEXTUAL-CONVENTION
    -- This is a type 1 enumeration.
    STATUS       current
    DESCRIPTION
        "Units of measure for media dimensions."
    SYNTAX       INTEGER {
                     tenThousandthsOfInches(3),  -- .0001
                     micrometers(4)
              }

PrtCapacityUnitTC ::= TEXTUAL-CONVENTION
    -- This is a type 1 enumeration.


Turner                 Printer MIB V2                   [Page 34]


INTERNET DRAFT          Printer MIB              January 22, 1999



    STATUS       current
    DESCRIPTION
        "Units of measure for media capacity."
    SYNTAX       INTEGER {
                     tenThousandthsOfInches(3),  -- .0001
                     micrometers(4),
                     sheets(8),
                     feet(16),
                     meters(17)
                 }

PrtPrintOrientationTC ::= TEXTUAL-CONVENTION
  -- This value is a type 1 enumeration
  STATUS  current
  DESCRIPTION
     "A generic representation for printing orientation on a
'page'."
  SYNTAX  INTEGER {
          other(1),
          portrait(3),
          landscape(4)
        }

PrtCoverStatusTC ::= TEXTUAL-CONVENTION
    -- This is a type 2 enumeration.
    STATUS     current
    DESCRIPTION
         "Values for encoding the state of a particular cover or
         access panel on the printer case or enclosure."
    SYNTAX INTEGER {
                 other(1),
                 coverOpen(3),
                 coverClosed(4),
                 interlockOpen(5),
                 interlockClosed(6)
                }

PrtSubUnitStatusTC ::= TEXTUAL-CONVENTION
    -- This is a type 1 enumeration.
    STATUS       current
    DESCRIPTION
         "Status of a printer sub-unit.

         The SubUnitStatus is an integer that is the sum of 5
         distinct values, Availability, Non-Critical, Critical,
         On-line, and Transitioning. These values are:

     Availability                           Value


Turner                 Printer MIB V2                   [Page 35]


INTERNET DRAFT          Printer MIB              January 22, 1999




            Available and Idle               0       000'b
            Available and Standby            2       010'b
            Available and Active             4       100'b
            Available and Busy               6       110'b
            Unavailable and OnRequest        1       001'b
            Unavailable because Broken       3       011'b
            Unknown                          5       101'b

    Non-Critical

            No Non-Critical Alerts           0
            Non-Critical Alerts              8

    Critical

            No Critical Alerts               0
            Critical Alerts                 16

    On-Line

            State is On-Line                 0
            State is Off-Line               32

    Transitioning

            Currently at intended state      0
            Transitioning to intended state 64  "

    SYNTAX       INTEGER (0..126)

PresentOnOff ::= TEXTUAL-CONVENTION
    -- This is a type 1 enumeration.
    STATUS       current
    DESCRIPTION
        "Presence and configuration of a device or feature."
    SYNTAX       INTEGER {
                     other(1),
                     on(3),
                     off(4),
                     notPresent(5)
                 }

CodedCharSet ::= TEXTUAL-CONVENTION
      -- This is a type 3 enumeration.
      STATUS     current
      DESCRIPTION



Turner                 Printer MIB V2                   [Page 36]


INTERNET DRAFT          Printer MIB              January 22, 1999



         "A coded character set value that specifies both a set
         of characters that may be used and an encoding (as one
         or more octets) that is used to represent the characters
         in the set. These values are to be used to identify the
         encoding employed for strings in the MIB where this is
         not fixed by the MIB.

         Some objects that allow a choice of coded character set
         are: the prtLocalizationCharacterSet object in the
         LocalizationTable and prtInterpreterDefaultCharSetIn.
         The prtGeneralCurrentLocalization and
         prtConsoleLocalization objects in turn contain the index
         in the LocalizationTable of the current localization
         (country, language, and coded character set) of the
         'description' objects and the console, respectively.

         The space of the coded character set enumeration has
         been divided into three regions. The first region (3-
         999) consists of coded character sets that have been
         standardized by some standard setting organization. This
         region is intended for standards that do not have subset
         implementations. The second region (1000-1999) is for
         the Unicode and ISO/IEC 10646 coded character sets
         together with a specification of a (set of) sub-
         repertoires that may occur.  The third region (>1999) is
         intended for vendor specific coded character sets.

         NOTE: Unicode and ISO 10646 character coded data may be
         processed and stored in either Big Endian (most
         significant octet first) or Little Endian (least
         significant octet first) order.  Intel x86, VAX, and
         Alpha/AXP architectures are examples of Little Endian
         processor architectures. Furthermore, in environments
         where either order may occur, so-called Unicode BYTE
         ORDER MARK (BOM) character (which is ISO 10646 ZERO
         WIDTH NO BREAK SPACE), coded as FEFF in two octets and
         0000FEFF in four octets is used at the beginning of the
         data as a signature to indicate the order of the
         following data (See ISO 10646 Annex F).  Thus either
         ordering and BOM may occur in print data streams sent to
         the interpreter.  However, ISO 8824/8825 (ASN.1/BER)
         used by SNMP is quite clear that Big Endian order shall
         be used and BOM shall NOT be used in transmission in the
         protocol. Transmitting Unicode in Big Endian order in
         SNMP should not prove to be a hardship for Little Endian
         machines, since SNMP ASN.1/BER requires integers to be
         transmitted in Big Endian order as well.  So SNMP
         implementations on Little Endian machines are already


Turner                 Printer MIB V2                   [Page 37]


INTERNET DRAFT          Printer MIB              January 22, 1999



         reversing the order of integers to make them Big Endian
         for transmission via SNMP.  Also Unicode characters are
         usually treated as two-octet integers, not short text
         strings, so that it will be straightforward for Little
         Endian machines to reverse the order of Unicode
         character octets as well before transmitting them and
         after receiving them via the SNMP protocol.

         Where a given coded character set may be known by more
         than one name, the most commonly known name is used as
         the name of the enumeration and other names are shown in
         the comments.  The comments also indicate where to find
         detailed information on the coded character set and
         briefly characterize its relationship to other similar
         coded character sets.

         The current list of character sets and their enumerated
         values used to reference them is contained in the IANA
         Character Set registry.  The enum value is indicated by
         the MIB enum entry in the registry.  The enum symbol is
         indicated by the Alias that starts with 'cs' for
         character set.

         The IANA character sets registry is available via
         anonymous ftp.

         The ftp server is ftp.isi.edu. The subdirectory is /in-
         notes/iana/assignments/.

         The file name is character-sets.

         To add a character set to the IANA Registry:

         1. Format an entry like those in the current list,
         omitting the MIBenum value.
         2. Send the entry with a request to add the entry to the
         character set list to iana@ISI.EDU.
         3. The IANA will supply a unique MIBenum value and
         update the list."

     SYNTAX     INTEGER {
        other(1)      -- used if the designated coded
                      -- character set is not currently in
                      -- the enumeration

      -- See IANA Registry for standard character sets in the
      -- MIBenum range of 3-999.



Turner                 Printer MIB V2                   [Page 38]


INTERNET DRAFT          Printer MIB              January 22, 1999



      -- See IANA Registry for Unicode and vendor-supplied
      -- combinations of ISO collections and character sets based
      -- on Unicode in the MIBenum range of 1000-1999.
      -- See IANA Registry for vendor developed character sets
      -- in the MIBenum range of 2000-xxxx.
   }


--
-- General Group textual-conventions
--

PrtGeneralResetTC ::= TEXTUAL-CONVENTION
    -- This value is a type 3 enumeration
    STATUS     current
    DESCRIPTION
      "Values for reading and writing the prtGeneralReset object.

       If a device does not have NVRAM, the device shall none the
       less respond to a SET with the value resetToNVRAM(5) with
       some sort of warm reset that resets the device to some
       implementation-defined state that is preferably under
       control of the system administrator by some means outside
       the scope of this MIB specification."
       SYNTAX     INTEGER {
                   notResetting(3),
                   powerCycleReset(4), -- Cold Start
                   resetToNVRAM(5), -- Warm Start
                   resetToFactoryDefaults(6) -- Reset contents of
                                             -- NVRAM to factory
                                             -- defaults
               }

--
-- Channel Group textual-conventions
--

PrtChannelStateTC ::= TEXTUAL-CONVENTION
    -- This value is a type 1 enumeration
    STATUS       current
    DESCRIPTION
         "The state of this print job delivery channel. The value
         determine whether control information and print data is
         allowed through this channel."
   SYNTAX     INTEGER {
                   other(1),
                   printDataAccepted(3),
                   noDataAccepted(4)


Turner                 Printer MIB V2                   [Page 39]


INTERNET DRAFT          Printer MIB              January 22, 1999



               }

PrtChannelTypeTC ::= TEXTUAL-CONVENTION
    --  This is a type 2 enumeration.
    STATUS     current
    DESCRIPTION
        "This enumeration indicates the type of channel that is
        receiving jobs."
    SYNTAX     INTEGER {
               other(1),
               chSerialPort(3),
               chParallelPort(4),
               chIEEE1284Port(5),
               chSCSIPort(6),
               chAppleTalkPAP(7),
                 -- AppleTalk Printer
                 -- Access Protocol (PAP)
                 --
                 -- prtChannelInformation entry:
                 --
                 -- Printer Name
                 --   Keyword:       Name
                 --   Syntax:        Name
                 --   Status:   Optional
                 --   Multiplicity: Single
                 --   Description:  The name of the
                 --     printer within the AppleTalk
                 --     naming scope
               chLPDServer(8),
                 -- prtChannelInformation entry:
                 --
                 -- Printer queue name
                 --   Keyword:       Queue
                 --   Syntax:        Name
                 --   Status:        Mandatory
                 --   Multiplicity:  Single
                 --   Description: queue name as
                 --     defined in RFC 1179.
               chNetwareRPrinter(9),
                 -- Novell, Inc.
                 -- For each entry of this type, the
                 -- prtChannelInformation must have a pair
                 -- of keywords. For Netware 3.x channels
                 -- this must be a (PServer, Printer) pair.
                 -- For Netware 4.x channels and for
                 -- IntranetWare channels this must be a
                 -- (NDSTree, NDSPrinter) pair.
                 --


Turner                 Printer MIB V2                   [Page 40]


INTERNET DRAFT          Printer MIB              January 22, 1999



                 -- prtChannelInformation entries:

                 -- Print Server Name
                 --   Keyword:        PServer
                 --   Syntax:    Name
                 --   Status:         Mandatory
                 --   Multiplicity: Single
                 --   Description:  The Pserver's SAP name
                 --
                 -- Printer Number
                 --   Keyword:        Printer
                 --   Syntax:         Integer
                 --   Status:    Mandatory
                 --   Multiplicity: Single
                 --   Description:  The printer number
                 --
                 -- NDSTree
                 --   Keyword:      NDSTree
                 --   Syntax:       Name
                 --   Multiplicity: Single
                 --   Description:  The tree's SAP name
                 --
                 -- NDS Printer object
                 --   Keyword:      NDSPrinter
                 --   Syntax:       Text (Unicode)
                 --   Status:       Mandatory
                 --   Multiplicity: Single
                 --   Description:  The fully qualified
                 --     name of the Printer
                 --
                 -- In the Netware 3.x environment, the
                 -- client checks the Bindery object
                 -- representing the named PServer. The
                 -- client then checks for queues which
                 -- are associated with the numbered
                 -- printer. In the 4.x and IntraNetware
                 -- environment, the client looks up the
                 -- queues which are associated with the
                 -- NDS Printer Object in the named Tree.
                 -- Depending on client access rights to
                 -- those queues, the client submits jobs
                 -- to the appropriate queue.
               chNetwarePServer(10),
                 -- Novell,Inc.
                 -- For each entry of this type, the
                 -- prtChannelInformation must have a pair
                 -- of keywords. For Netware 3.x channels
                 -- this must be a (Server, PServer) pair.


Turner                 Printer MIB V2                   [Page 41]


INTERNET DRAFT          Printer MIB              January 22, 1999



                 -- For Netware 4.x and IntranetWare
                 -- channels, this must be a
                 -- (NDSTree, NDSPServer) pair.
                 --
                 -- prtChannelInformation entries:
                 --
                 -- Server Name
                 --   Keyword:       Server
                 --   Syntax:   Name
                 --   Status:        Mandatory
                 --   Multiplicity: Single
                 --   Description:  The SAP name of the
                 --   server for which the PServer is
                 --   defined.
                 --
                 -- PServer
                 --   Keyword:      PServer
                 --   Syntax:       Name
                 --   Status:       Mandatory
                 --   Multiplicity: Single
                 --   Description:  The bindery name of
                 --     the PServer
                 --
                 -- NDS Tree
                 --   Keyword:      NDSTree
                 --   Syntax:       Name
                 --   Status:       Mandatory
                 --   Multiplicity: Single
                 --   Description:  The NDS Tree name
                 --
                 -- PServer
                 --   Keyword:      NDSPServer
                 --   Syntax:       Text (Unicode)
                 --   Status:       Mandatory
                 --   Multiplicity: Single
                 --   Description:  The fully qualified
                 --     name of the PServer object in the
                 --     tree.
                 --
                 -- In the 3.x environment, the client
                 -- checks the bindery object
                 -- representing the named PServer on the
                 -- named Server. In the 4.x and
                 -- IntranetWare environment,
                 -- the client checks the NDS object
                 -- representing the named PServer in the
                 -- named Tree. In either case, the
                 -- client then checks for all queues


Turner                 Printer MIB V2                   [Page 42]


INTERNET DRAFT          Printer MIB              January 22, 1999



                 -- associated with the Pserver object.
                 -- Depending on client access rights
                 -- to those queues, the client submits
                 -- jobs to the appropriate queue.
               chPort9100(11),
                 -- DEPRECATED
               chAppSocket(12),
                 -- A bi-directional, LPD-like,
                 -- protocol using 9101 for
                 -- control and 9100 for data.
                 -- Adobe Systems, Inc.
               chFTP(13),         -- RFC 959
               chTFTP(14),        -- RFC 1350
               chDLCLLCPort(15),
               chIBM3270(16),     -- IBM Coax
               chIBM5250(17),     -- IBM Twinax
               chFax(18),
               chIEEE1394(19),
               chTransport1(20),
                 -- TCP port 35, see reserved TCP port list
                 -- in RFC 1700 or current "Assigned
                 -- Numbers" RFC. This RFC should also be
                 -- referenced for other channel
                 -- enumerations utilizing TCP port
                 -- numbers 0 through 1024.
               chCPAP(21),      -- TCP port 170, Digital
                                -- Equipment Corp.
               chPCPrint(26),   -- Banyan
               chServerMessageBlock(27),
                 -- File/Print sharing protocol used by
                 -- various network operating systems
                 -- from IBM 3Com, Microsoft and others
                 --
                 -- prtChannelInformation entry:
                 --
                 -- Service Name
                 --   Keyword:       Name
                 --   Syntax:       Name
                 --   Status:   Optional
                 --   Multiplicity: Single
                 --   Description:  The service name of
                 --     the printer
               chPSM(28),       -- Printing Systems
                                -- Manager, IBM
               chSystemObjectManager(31), -- IBM
               chDECLAT(32),
                 -- Digital Equipment Corp.
                 --


Turner                 Printer MIB V2                   [Page 43]


INTERNET DRAFT          Printer MIB              January 22, 1999



                 -- prtChannelInformation entries:
                 --
                 -- Port Name
                 --   Keyword:      Port
                 --   Syntax:       Name
                 --   Status:       Conditionally
                 --                 Mandatory
                 --                 (see note below)
                 --   Multiplicity: Single
                 --   Description:  LAT port name
                 --
                 -- Service Name
                 --    Keyword:      Service
                 --    Syntax:       Name
                 --    Status:       Conditionally
                 --                  Mandatory
                 --    Multiplicity: Single
                 --    Description:  LAT service
                 --      name
                 --
                 -- The LAT channel may be
                 -- identified by either a port or
                 -- service, so either a
                 -- Port or Service entry must be
                 -- specified, but not both.
               chNPAP(33),
               chUSB(34),    -- Universal Serial Bus
               chIRDA(35),   -- Infrared Data Assoc. Prot.
               chPrintXChange(36), -- PrintXChange Protocol
               chPortTCP(37),
                 -- A unidirectional "raw" TCP
                 -- channel that uses an administratively
                 -- assigned TCP port address.
                 --
                 -- prtChannelInformation entry:
                 --
                 -- Port Number
                 --    Keyword:      Port
                 --    Syntax:       decimal number
                 --    Status:       Mandatory
                 --    Multiplicity: Single
                 --    Description:  TCP port number
               chBidirPortTCP(38),
                 -- A bi-directional version of chPortTCP
                 --
                 -- prtChannelInformation entries:
                 -- (See chPortTCP)
               chUNPP(39),


Turner                 Printer MIB V2                   [Page 44]


INTERNET DRAFT          Printer MIB              January 22, 1999



                 -- Universal Network Printing
                 -- Protocol(UNPP). A bi-directional,
                 -- multiport network printing
                 -- application protocol available on
                 -- multiple transport protocols.
                 -- Underscore, Inc.
                 -- Contact: info@underscore.com
               chAppleTalkADSP(40),
                 -- AppleTalk Data Stream Protocol.
                 -- ADSP is part of the AppleTalk
                 -- suite of protocols.
                 -- It is a symmetric, connection-
                 -- oriented protocol that makes
                 -- possible the establishment
                 -- and maintenance of full-duplex
                 -- streams of data bytes between
                 -- two sockets in an AppleTalk
                 -- internet.
                 -- See Inside AppleTalk, second
                 -- Edition, by Sidhu, Andrews and
                 -- Oppenheimer.
               chPortSPX(41),
                 -- Sequenced Packet Exchange (SPX)
                 -- socket.
                 -- Novell, Inc. Similar to TCP, a
                 -- bi-directional data pipe using
                 -- Novell SPX as a transport.
                 --
                 -- prtChannelInformation entries:
                 --
                 -- Network Number
                 --   Keyword:       Net
                 --   Syntax:   HexString
                 --   Status:   Mandatory
                 --   Multiplicity: Single
                 --   Description:  The network number
                 --
                 -- Node Number
                 --   Keyword:       Node
                 --   Syntax:   HexString
                 --   Status:   Mandatory
                 --   Multiplicity: Single
                 --   Description:  The node number
                 --
                 -- Socket Number
                 --   Keyword:       Socket
                 --   Syntax:   HexString
                 --   Status:   Mandatory


Turner                 Printer MIB V2                   [Page 45]


INTERNET DRAFT          Printer MIB              January 22, 1999



                 --   Multiplicity: Single
                 --   Description:  The SPX socket number
                 --
                 -- There must be exactly one "Net" and
                 -- one "Node" and one "Socket" entry. A
                 -- HexString is a binary value
                 -- represented as a string of
                 -- ASCII characters using hexadecimal
                 -- notation.
               chPortHTTP(42),
                 -- Hypertext Transfer Protocol. See IETF
                 -- documents relating to HTTP 1.0/1.1
                 -- (RFCs 1945 and 2068,etc.)
               chNDPS(43)
                 -- Novell, Inc.
                 --
                 -- prtChannelInformation entry:
                 --
                 -- Printer Agent Name
                 --   Keyword:      PA
                 --   Syntax:   Name
                 --   Status:   Mandatory
                 --   Multiplicity: Single
                 --   Description:  The NDPS Printer
                 --      Agent Name
    }
-- Interpreter Group textual conventions

PrtInterpreterLangFamilyTC ::= TEXTUAL-CONVENTION
    -- This value is a type 2 enumeration.
    STATUS     current
    DESCRIPTION
      "This enumeration indicates the type of interpreter that is
       receiving jobs."
    SYNTAX     INTEGER {
        other(1),
        unknown(2),
        langPCL(3),      -- PCL.  Starting with PCL version 5,
                         -- HP-GL/2 is included as part of the
                         -- PCL language.
                         -- PCL and HP-GL/2 are registered
                         -- trademarks of Hewlett-Packard
                         -- Company.
        langHPGL(4),     -- Hewlett-Packard Graphics Language.
                         -- HP-GL is a registered trademark of
                         -- Hewlett-Packard Company.
        langPJL(5),      -- Peripheral Job Language. Appears in
                         -- the data stream between data intended


Turner                 Printer MIB V2                   [Page 46]


INTERNET DRAFT          Printer MIB              January 22, 1999



                         -- for a page description language.
                         -- Hewlett-Packard Co.
        langPS(6),       -- PostScript (tm) Language
                         -- Postscript - a trademark of Adobe
                         -- Systems Incorporated which may be
                         -- registered in certain jurisdictions
        langIPDS(7),     -- Intelligent Printer Data Stream
                         -- Bi-directional print data stream for
                         -- documents consisting of data objects
                         -- (text, image, graphics, bar codes),
                         -- resources (fonts, overlays) and page,
                         -- form and finishing instructions.
                         -- Facilitates system level device
                         -- control, document tracking and error
                         -- recovery throughout the print
                         -- process.
                         -- Pennant Systems, IBM
        langPPDS(8),     -- IBM Personal Printer Data Stream.
                         -- Originally called IBM ASCII, the name
                         -- was changed to PPDS when the Laser
                         -- Printer was introduced in 1989.
                         -- Lexmark International, Inc.
        langEscapeP(9),  -- Epson Corp.
        langEpson(10),
        langDDIF(11),    -- Digital Document Interchange Format
                         -- Digital Equipment Corp., Maynard MA
        langInterpress(12),
                         -- Xerox Corp.
        langISO6429(13), -- ISO 6429.  Control functions for
                         -- Coded Character Sets (has ASCII
                         -- control characters, plus additional
                         -- controls for
                         -- character imaging devices.)
                         -- ISO Standard, Geneva, Switzerland
        langLineData(14),-- line-data:  Lines of data as
                         -- separate ASCII or EBCDIC records
                         -- and containing no control functions
                         -- (no CR, LF, HT, FF, etc.)
                         -- For use with traditional line
                         -- printers.  May use CR and/or LF to
                         -- delimit lines, instead of records.
                         -- See ISO 10175 Document Printing
                         -- Application(DPA)
                         -- ISO standard, Geneva, Switzerland
        langMODCA(15),   -- Mixed Object Document Content
                         -- Architecture
                         -- Definitions that allow the
                         -- composition, interchange, and


Turner                 Printer MIB V2                   [Page 47]


INTERNET DRAFT          Printer MIB              January 22, 1999



                         -- presentation of final form
                         -- documents as a collection of data
                         -- objects (text, image, graphics, bar
                         -- codes), resources (fonts, overlays)
                         -- and page, form and finishing
                         -- instructions.
                         -- Pennant Systems, IBM
        langREGIS(16),   -- Remote Graphics Instruction Set,
                         -- Digital Equipment Corp., Maynard MA
        langSCS(17),     -- SNA Character String
                         -- Bi-directional print data stream for
                         -- SNA LU-1 mode of communication.
                         -- IBM
        langSPDL(18),    -- ISO 10180 Standard Page Description
                         -- Language
                         -- ISO Standard
        langTEK4014(19), -- Tektronix Corp.
        langPDS(20),
        langIGP(21),     -- Printronix Corp.
        langCodeV(22),   -- Magnum Code-V, Image and printer
                         -- control language used to control
                         -- impact/dot-matrix printers.
                         -- QMS, Inc., Mobile AL
        langDSCDSE(23),  -- DSC-DSE:  Data Stream Compatible and
                         -- Emulation Bi-directional print data
                         -- stream for non-SNA (DSC) and SNA LU-3
                         -- 3270 controller (DSE) communications
                         -- IBM
        langWPS(24),     -- Windows Printing System, Resource
                         -- based command/data stream used by
                         -- Microsoft At Work Peripherals.
                         -- Developed by the Microsoft
                         -- Corporation.
        langLN03(25),    -- Early DEC-PPL3, Digital Equipment
                         -- Corp.
        langCCITT(26),
        langQUIC(27),    -- QUIC (Quality Information Code), Page
                         -- Description Language for laser
                         -- printers. Included graphics, printer
                         -- control capability and emulation of
                         -- other well-known printer .
                         -- QMS, Inc.
        langCPAP(28),    -- Common Printer Access Protocol
                         -- Digital Equipment Corp.
        langDecPPL(29),  -- Digital ANSI-Compliant Printing
                         -- Protocol
                         -- (DEC-PPL)
                         -- Digital Equipment Corp.


Turner                 Printer MIB V2                   [Page 48]


INTERNET DRAFT          Printer MIB              January 22, 1999



        langSimpleText(30),
                         -- simple-text:  character coded data,
                         -- including NUL, CR , LF, HT, and FF
                         -- control characters.  See ISO 10175
                         -- Document Printing Application (DPA)
                         -- ISO standard, Geneva, Switzerland
        langNPAP(31),    -- Network Printer Alliance Protocol
                         -- (NPAP). This protocol has been
                         -- superseded by the IEEE 1284.1 TIPSI
                         -- Std (ref. LangTIPSI(49)).
        langDOC(32),     -- Document Option Commands, Appears in
                         -- the data stream between data
                         -- intended for a page description .
                         -- QMS, Inc.
        langimPress(33), -- imPRESS, Page description language
                         -- originally developed for the
                         -- ImageServer product line. A binary
                         -- language providing representations
                         -- of text, simple graphics, and some
                         -- large forms (simple
                         -- bit-map and CCITT group /
                         -- encoded).The
                         -- language was intended to be sent over
                         -- an 8-bit channel and supported early
                         -- document preparation languages (e.g.
                         -- TeX and TROFF).
                         -- QMS, Inc.
        langPinwriter(34),
                         -- 24 wire dot matrix printer  for
                         -- USA, Europe, and Asia except
                         -- Japan.
                         -- More widely used in Germany, and
                         -- some Asian countries than in US.
                         -- NEC
        langNPDL(35),    -- Page printer  for Japanese market.
                         -- NEC
        langNEC201PL(36),-- Serial printer language used in
                         -- the Japanese market.
                         -- NEC
        langAutomatic(37),
                         -- Automatic PDL sensing.  Automatic
                         -- sensing of the interpreter
                         -- language family by the printer
                         -- examining the document content.
                         -- Which actual interpreter language
                         -- families are sensed depends on
                         -- the printer implementation.
        langPages(38),   -- Page printer Advanced Graphic


Turner                 Printer MIB V2                   [Page 49]


INTERNET DRAFT          Printer MIB              January 22, 1999



                         -- Escape Set
                         -- IBM Japan
        langLIPS(39),    -- LBP Image Processing System
        langTIFF(40),    -- Tagged Image File Format (Aldus)
        langDiagnostic(41),
                         -- A hex dump of the input to the
                         -- interpreter
        langPSPrinter(42),
                         -- The PostScript Language used for
                         -- control (with any PDLs)
                         -- Adobe Systems Incorporated
        langCaPSL(43),   -- Canon Print Systems Language
        langEXCL(44),    -- Extended Command Language
                         -- Talaris Systems Inc.
        langLCDS(45),    -- Line Conditioned Data Stream
                         -- Xerox Corporation
        langXES(46),     -- Xerox Escape Sequences
                         -- Xerox Corporation
        langPCLXL(47),   -- Printer Control Language. Extended
                         -- language features for printing, and
                         -- printer control.
                         -- Hewlett-Packard Co.
        langART(48),     -- Advanced Rendering Tools (ART).
                         -- Page Description language
                         -- originally developed for the Laser
                         -- Press printers.
                         -- Technical reference manual: "ART IV
                         -- Reference Manual", No F33M.
                         -- Fuji Xerox Co., Ltd.
        langTIPSI(49),   -- Transport Independent Printer
                         -- System Interface (ref. IEEE Std.
                         -- 1284.1)
        langPrescribe(50),
                         -- Page description and printer
                         -- control language. It can be
                         -- described with ordinary ASCII
                         -- Technical reference manual:
                         -- "PRESCRIBE II Programming Manual"
        langLinePrinter(51),
                         -- A simple-text character stream which
                         -- supports the control codes LF, VT,
                         -- FF, and plus Centronics or
                         -- Dataproducts Vertical Format Unit
                         -- (VFU) language is commonly used on
                         -- many older model line and matrix
                         -- printers.
        langIDP(52),     -- Imaging Device Protocol
                         -- Apple Computer.


Turner                 Printer MIB V2                   [Page 50]


INTERNET DRAFT          Printer MIB              January 22, 1999



        langXJCL(53),    -- Xerox Job Control Language (JCL).
                         -- A Job Control language originally
                         -- developed for the LaserPress printers
                         -- and is capable of switching PDLs.
                         -- Technical reference manual:
                         -- "ART IV Reference Manual", No F33M.
                         -- Fuji Xerox Co., Ltd.
        langPDF(54),     -- Adobe Portable Document Format
                         -- Adobe Systems, Inc.
        langRPDL(55),    -- Ricoh Page Description Language for
                         -- printers.
                         -- Technical manual "RPDL command
                         -- reference" No.307029
                         -- RICOH, Co. LTD
        langIntermecIPL(56),
                         -- Intermec Printer Language for label
                         -- printers.
                         -- Technical Manual: "IPL Programmers
                         -- Reference Manual"
                         -- Intermec Corporation
        langUBIFingerprint(57),
                         -- An intelligent basic-like programming
                         -- language for label printers.
                         -- Reference Manual: "UBI Fingerprint
                         -- 7.1", No. 1-960434-00
                         -- United Barcode Industries
        langUBIDirectProtocol(58),
                         -- An intelligent control language for
                         -- label printers.
                         -- Programmers guide: " UBI Direct
                         -- Protocol", No. 1-960419-00
                         -- United Barcode Industries
        langFujitsu(59)
                         -- Fujitsu Printer Language
                         -- Reference Manual:
                         -- "FM Printer Sequence" No. 80HP-0770
                         -- FUJITSU LIMITED
}

--
-- Input/Output Group Textual Conventions
--

PrtInputTypeTC ::= TEXTUAL-CONVENTION
    -- This is a type 2 enumeration
    STATUS current
    DESCRIPTION



Turner                 Printer MIB V2                   [Page 51]


INTERNET DRAFT          Printer MIB              January 22, 1999



         "The type of technology (discriminated primarily
         according to feeder mechanism type) employed by a
         specific component or components."
    SYNTAX INTEGER {
                other(1),
                unknown(2),
                sheetFeedAutoRemovableTray(3),
                sheetFeedAutoNonRemovableTray(4),
                sheetFeedManual(5),
                continuousRoll(6),
                continuousFanFold(7)
                   }

PrtOutputTypeTC ::= TEXTUAL-CONVENTION
     -- This is a type 2 enumeration
     STATUS current
     DESCRIPTION
          "The Type of technology supported by this output sub-
         unit"
     SYNTAX INTEGER {
                    other(1),
                    unknown(2),
                    removableBin(3),
                    unRemovableBin(4),
                    continuousRollDevice(5),
                    mailBox(6),
                    continuousFanFold(7)
                 }

PrtOutputStackingOrderTC ::= TEXTUAL-CONVENTION
     -- This is a type 1 enumeration
     STATUS current
     DESCRIPTION
         "The current state of the stacking order for the
         associated output sub-unit. 'firstToLast' means that as
         pages are output, the front of the next page is placed
         against the back of the previous page. 'lastToFirst'
         means that as pages are output, the back of the next
         page is placed against the front of the previous page."
     SYNTAX INTEGER {
                    unknown(2),
                    firstToLast(3),
                    lastToFirst(4)
                 }

PrtOutputPageDeliveryOrientationTC ::= TEXTUAL-CONVENTION
     -- This is a type 1 enumeration
     STATUS current


Turner                 Printer MIB V2                   [Page 52]


INTERNET DRAFT          Printer MIB              January 22, 1999



     DESCRIPTION
         "The reading surface that will be 'up' when pages are
         delivered to the associated output sub-unit. Values are
         Face-Up and Face-Down (Note: interpretation of these
         values is, in general, context-dependent based on
         locale; presentation of these values to an end-user
         should be normalized to the expectations of the user."
     SYNTAX INTEGER {
                    faceUp(3),
                    faceDown(4)
                 }

--
-- Marker Group Textual Conventions
--

PrtMarkerMarkTechTC ::= TEXTUAL-CONVENTION
     -- This value is a type 2 enumeration
     STATUS current
     DESCRIPTION
         "The type of marking technology used for this marking
         sub-unit"
     SYNTAX     INTEGER {
                   other(1),
                   unknown(2),
                   electrophotographicLED(3),
                   electrophotographicLaser(4),
                   electrophotographicOther(5),
                   impactMovingHeadDotMatrix9pin(6),
                   impactMovingHeadDotMatrix24pin(7),
                   impactMovingHeadDotMatrixOther(8),
                   impactMovingHeadFullyFormed(9),
                   impactBand(10),
                   impactOther(11),
                   inkjetAqueous(12),
                   inkjetSolid(13),
                   inkjetOther(14),
                   pen(15),
                   thermalTransfer(16),
                   thermalSensitive(17),
                   thermalDiffusion(18),
                   thermalOther(19),
                   electroerosion(20),
                   electrostatic(21),
                   photographicMicrofiche(22),
                   photographicImagesetter(23),
                   photographicOther(24),
                   ionDeposition(25),


Turner                 Printer MIB V2                   [Page 53]


INTERNET DRAFT          Printer MIB              January 22, 1999



                   eBeam(26),
                   typesetter(27)
               }

PrtMarkerCounterUnitTC ::= TEXTUAL-CONVENTION
    -- This value is a type 1 enumeration
    STATUS     current
    DESCRIPTION
        "The unit that will be used by the printer when reporting
        counter values for this marking sub-unit.  The
        time units of measure are provided for a device like a
        strip recorder that does not or cannot track the physical
        dimensions of the media and does not use characters,
        lines or sheets."

    SYNTAX     INTEGER {
                   tenThousandthsOfInches(3),  -- .0001
                   micrometers(4),
                   characters(5),
                   lines(6),
                   impressions(7),
                   sheets(8),
                   dotRow(9),
                   hours(11),
                   feet(16),
                   meters(17)
               }

PrtMarkerSuppliesTypeTC ::= TEXTUAL-CONVENTION
    --   This value is a type 3 enumeration
    STATUS     current
    DESCRIPTION
        "The type of this supply."
    SYNTAX     INTEGER {
                   other(1),
                   unknown(2),
                   toner(3),
                   wasteToner(4),
                   ink(5),
                   inkCartridge(6),
                   inkRibbon(7),
                   wasteInk(8),
                   opc(9), -- photo conductor
                   developer(10),
                   fuserOil(11),
                   solidWax(12),
                   ribbonWax(13),
                   wasteWax(14),


Turner                 Printer MIB V2                   [Page 54]


INTERNET DRAFT          Printer MIB              January 22, 1999



                   fuser(15),
                   coronaWire(16),
                   fuserOilWick(17),
                   cleanerUnit(18),
                   fuserCleaningPad(19),
                   transferUnit(20),
                   tonerCartridge(21),
                   fuserOiler(22),
            -- Values for Finisher MIB
                   water(23),
                   wasteWater(24),
                   glueWaterAdditive(25),
                   wastePaper(26),
                   bindingSupply(27),
                   bandingSupply(28),
                   stitchingWire(29),
                   shrinkWrap(30),
                   paperWrap(31),
                   staples(32),
                   inserts(33),
                   covers(34)
            -- End of values for Finisher MIB
               }

PrtMarkerSuppliesSupplyUnitTC ::= TEXTUAL-CONVENTION
    -- This value is a type 1 enumeration
    STATUS     current
    DESCRIPTION
        "Unit of this marker supply container/receptacle."
    SYNTAX     INTEGER {
                  tenThousandthsOfInches(3),  -- .0001
                  micrometers(4),
                  impressions(7),
                  sheets(8),
                  hours(11),
                  thousandthsOfOunces(12),
                  tenthsOfGrams(13),
                  hundrethsOfFluidOunces(14),
                  tenthsOfMilliliters(15),
                  feet(16),
                  meters(17),
           -- Value for Finisher MIB
                  items(18)        -- e.g. number of staples
            }

PrtMarkerSuppliesClassTC ::= TEXTUAL-CONVENTION
    --  This value is a type 1 enumeration
    STATUS     current


Turner                 Printer MIB V2                   [Page 55]


INTERNET DRAFT          Printer MIB              January 22, 1999



    DESCRIPTION
        "Indicates whether this supply entity represents a supply
        that is consumed or a receptacle that is filled."
    SYNTAX     INTEGER {
                   other(1),
                   supplyThatIsConsumed(3),
                   receptacleThatIsFilled(4)
               }

PrtMarkerColorantRoleTC ::= TEXTUAL-CONVENTION
    -- This value is a type 1 enumeration
    STATUS       current
    DESCRIPTION
         "The role played by this colorant."
    SYNTAX     INTEGER { --  Colorant Role
                   other(1),
                   process(3),
                   spot(4)
               }

--
-- Media Path Textual Conventions
--

PrtMediaPathMaxSpeedPrintUnitTC ::= TEXTUAL-CONVENTION
    -- This value is a type 1 enumeration
    STATUS       current
    DESCRIPTION
         "The unit of measure used in specifying the speed of all
         media paths in the printer."
    SYNTAX     INTEGER {
                   tenThousandthsOfInchesPerHour(3),-- .0001/hour
                   micrometersPerHour(4),
                   charactersPerHour(5),
                   linesPerHour(6),
                   impressionsPerHour(7),
                   sheetsPerHour(8),
                   dotRowPerHour(9),
                   feetPerHour(16),
                   metersPerHour(17)
               }

PrtMediaPathTypeTC ::= TEXTUAL-CONVENTION
    --   This value is a type 2 enumeration
    STATUS     current
    DESCRIPTION
        "The type of the media path for this media path."
    SYNTAX     INTEGER {


Turner                 Printer MIB V2                   [Page 56]


INTERNET DRAFT          Printer MIB              January 22, 1999



                   other(1),
                   unknown(2),
                   longEdgeBindingDuplex(3),
                   shortEdgeBindingDuplex(4),
                   simplex(5)
               }

--
-- Interpreter Group Textual Conventions
--


PrtInterpreterTwoWayTC ::= TEXTUAL-CONVENTION
    -- This is a type 1 enumeration
    STATUS current
    DESCRIPTION
         "Indicates whether or not this interpreter returns
         information back to the host."
    SYNTAX          INTEGER {
                    yes(3),
                    no(4)
                }

--
-- Console Group Textual Conventions
--

PrtConsoleColorTC ::= TEXTUAL-CONVENTION
    -- This value is a type 2 enumeration
    STATUS     current
    DESCRIPTION
        "The color of this light."
    SYNTAX INTEGER {
               other(1),
               unknown(2),
               white(3),
               red(4),
               green(5),
               blue(6),
               cyan(7),
               magenta(8),
               yellow(9),
               orange(10)
             }


--
-- Alert Group Textual Conventions


Turner                 Printer MIB V2                   [Page 57]


INTERNET DRAFT          Printer MIB              January 22, 1999



--

PrtAlertSeverityLevelTC ::= TEXTUAL-CONVENTION
    -- This value is a type 1 enumeration
    STATUS     current
    DESCRIPTION
         "The level of severity of this alert table entry.  The
         printer determines the severity level assigned to each
         entry into the table. A warning is defined to be a non-
         critical alert. The value also indicates whether the
         event is a binary change event or a unary change event."
    SYNTAX     INTEGER {
                   other(1),
                   criticalBinaryChangeEvent(3),
                   warningUnaryChangeEvent(4),
                   warningBinaryChangeEvent(5)
               }

PrtAlertTrainingLevelTC ::= TEXTUAL-CONVENTION
    -- This value is a type 2 enumeration
    STATUS     current
    DESCRIPTION
         "The level of training required to handle this alert, if
         human intervention is required. The
         noInterventionRequired value should be used if the event
         does not require any human intervention. The training
         level is an enumeration that is determined and assigned
         by the printer manufacturer based on the information or
         the training required to handle this alert.  The printer
         will break alerts into these different training levels.
         It is the responsibility of the management application
         in the system to determine how a particular alert is
         handled and how and to whom that alert is routed.  The
         following are the four training levels of alerts:

         Field Service - Alerts that typically require advanced
                         training and technical knowledge of the
                         printer and its sub-units. An example of
                         a technical person would be a
                         manufacturer's Field Service
                         representative, or other person formally
                         trained by the manufacturer or similar
                         representative.
         Trained -       Alerts that require an intermediate or
                         moderate level of knowledge of the
                         printer and its sub-units. A typical
                         examples of alerts that a trained
                         operator can handle is replacing


Turner                 Printer MIB V2                   [Page 58]


INTERNET DRAFT          Printer MIB              January 22, 1999



                         toner cartridges.
         Untrained -     Alerts that can be fixed without prior
                         training either because the action to
                         correct the alert is obvious or the
                         printer can help the untrained person
                         fix the problem. A typical example of
                         such an alert is reloading paper trays
                         and emptying output bins on a low end
                         printer.
         Management -    Alerts that have to do with overall
                         operation of and configuration of the
                         printer. Examples of management events
                         are configuration change of sub-units."
    SYNTAX     INTEGER {
                   other(1),
                   unknown(2),
                   untrained(3),
                   trained(4),
                   fieldService(5),
                   management(6),
                   noInterventionRequired(7)
               }

PrtAlertGroupTC ::= TEXTUAL-CONVENTION
    -- This value is a type 1 enumeration for values in the range
    -- 1 to 29.
    -- Values of 30 and greater are type 2 enumerations and are
    -- for use in other MIBs that augment tables in the Printer
    -- MIB. Therefore, other MIBs may assign alert codes of 30 or
    -- higher to use the alert table from the Printer MIB without
    -- requiring revising and re-publishing this document.
    STATUS     current
    DESCRIPTION
         "The type of sub-unit within the printer model that this
         alert is related.  Input, output, and markers are
         examples of printer model groups, i.e., examples of
         types of sub-units. Wherever possible, these
         enumerations match the sub-identifier that identifies
         the relevant table in the printer MIB.

         NOTE: Alert type codes have been added for the host
         resources MIB storage table and device table. These
         additional types are for situations in which the
         printer's storage and device objects
         must generate alerts (and possibly traps for critical
         alerts)."
    SYNTAX     INTEGER {
                   other(1),


Turner                 Printer MIB V2                   [Page 59]


INTERNET DRAFT          Printer MIB              January 22, 1999



                   hostResourcesMIBStorageTable(3),
                   hostResourcesMIBDeviceTable(4),
                   generalPrinter(5),
                   cover(6),
                   localization(7),
                   input(8),
                   output(9),
                   marker(10),
                   markerSupplies(11),
                   markerColorant(12),
                   mediaPath(13),
                   channel(14),
                   interpreter(15),
                   consoleDisplayBuffer(16),
                   consoleLights(17),
                   alert(18),
           -- Values for Finisher MIB
                   finDevice(30),
                   finSupply(31),
                   finSupplyMediaInput(32),
                   finAttributeTable(33)
           -- End of values for Finisher MIB
               }

PrtAlertCodeTC ::= TEXTUAL-CONVENTION
    -- This value is a type 2 enumeration
    STATUS     current
    DESCRIPTION
         "The code that describes the type of alert for this
         entry in the table. Binary change event alerts describe
         states of the subunit while unary change event alerts
         describe a single event. The same alert code can be used
         for a binary change event or a unary change event,
         depending on implementation. Also, the same alert code
         can be used to indicate a critical or a non-critical
         (warning) alert, depending on implementation. The value
         of prtAlertSeverityLevel specifies binary vs. unary and
         critical vs. non-critical for each event for the
         implementation.

         While there are some specific codes for many subunits,
         the generic codes should be used for most subunit
         alerts. The network management station can then query
         the subunit specified by prtAlertGroup to determine
         further subunit status and other subunit information.

         An agent shall not add two entries to the alert table
         for the same event, one containing a generic event code


Turner                 Printer MIB V2                   [Page 60]


INTERNET DRAFT          Printer MIB              January 22, 1999



         and the other containing a specific event code; the
         agent shall add only one entry in the alert table for
         each event; either generic (preferred) or specific, not
         both.

         Implementation of the unary change event
         alertRemovalOfBinaryChangeEntry(1801) is optional. When
         implemented, this alert code shall indicate to network
         management stations that the trailing edge of a binary
         change event has occurred and the corresponding alert
         entry has been removed from the alert table. As with all
         events, the alertRemovalOfBinaryChangeEntry(1801) alert
         shall be placed at the end of the alert table. Such an
         alert table entry shall specify the following
         information:

         prtAlertSeverityLevel   warningUnaryChangeEvent(4)
         prtAlertTrainingLevel   noInterventionRequired(7)
         prtAlertGroup           alert(18)
         prtAlertGroupIndex      the index of the row in the
                                 alert table of the binary
                                 change event that this event
                                 has removed.
         prtAlertLocation        unknown (-2)
         prtAlertCode       alertRemovalOfBinaryChangeEntry(1801)
         prtAlertDescription     <description or null string>
         prtAlertTime            the value of sysUpTime at
                                 the time of the removal of the
                                 binary change event from the
                                 alert table.

         Optionally, the agent may generate a trap coincident
         with removing the binary change event and placing the
         unary change event alertRemovalOfBinaryChangeEntry(1801)
         in the alert table. For such a trap, the prtAlertIndex
         sent with the above trap parameters shall be the index
         of the alertRemovalOfBinaryChangeEvent row that was
         added to the prtAlertTable; not the index of the row
         that was removed from the prtAlertTable."
    SYNTAX     INTEGER {
                   other(1),
                        -- an event that is not represented
                        -- by one of the alert codes
                        -- specified below.
                   unknown(2),
                        -- The following generic codes are common
                        -- to multiple groups. The NMS may



Turner                 Printer MIB V2                   [Page 61]


INTERNET DRAFT          Printer MIB              January 22, 1999



                        -- examine the prtAlertGroup object
                        -- to determine what group to query for
                        -- further information.
                coverOpened(3),
                coverClosed(4),
                interlockOpened(5),
                interlockClosed(6),
                configurationChanged(7),
                jammed(8),
                subunitMissing(9),
                        -- The subunit tray, bin, etc.
                        -- has been removed.
                subunitLifeAlmostOver(10),
                subunitLifeOver(11),
                subunitAlmostEmpty(12),
                subunitEmpty(13),
                subunitAlmostFull(14),
                subunitFull(15),
                subunitNearLimit(16),
                subunitAtLimit(17),
                subunitOpened(18),
                subunitClosed(19),
                subunitTurnedOn(20),
                subunitTurnedOff(21),
                subunitOffline(22),
                subunitPowerSaver(23),
                subunitWarmingUp(24),
                subunitAdded(25),
                subunitRemoved(26),
                subunitResourceAdded(27),
                subunitResourceRemoved(28),
                subunitRecoverableFailure(29),
                subunitUnrecoverableFailure(30),
                subunitRecoverableStorageError(31),
                subunitUnrecoverableStorageError(32),
                subunitMotorFailure(33),
                subunitMemoryExhausted(34),
                subunitUnderTemperature(35),
                subunitOverTemperature(36),
                subunitTimingFailure(37),
                subunitThermistorFailure(38),
            -- general Printer group
                doorOpen(501),    -- DEPRECATED
                                  -- Use coverOpened(3)
                doorClosed(502),  -- DEPRECATED
                                  -- Use coverClosed(4)
                poweredUp(503),
                poweredDown(504),


Turner                 Printer MIB V2                   [Page 62]


INTERNET DRAFT          Printer MIB              January 22, 1999



                printerNMSReset(505),
                        -- The printer has been reset by some
                        -- network management station(NMS)
                        -- writing into 'prtGeneralReset'.
                printerManualReset(506),
                        -- The printer has been reset manually.
                printerReadyToPrint(507),
                        -- The printer is ready to print. (i.e.,
                        -- not warming up, not in power save
                        -- state, not adjusting print quality,
                        -- etc.).

            -- Input Group
                inputMediaTrayMissing(801),
                inputMediaSizeChanged(802),
                inputMediaWeightChanged(803),
                inputMediaTypeChanged(804),
                inputMediaColorChanged(805),
                inputMediaFormPartsChange(806),
                inputMediaSupplyLow(807),
                inputMediaSupplyEmpty(808),
                inputMediaChangeRequest(809),
                    -- An interpreter has detected that a
                    -- different medium is need in this input
                    -- tray subunit. The prtAlertDescription may
                    -- be used to convey a human readable
                    -- description of the medium required to
                    -- satisfy the request.
                inputManualInputRequest(810),
                    -- An interpreter has detected that manual
                    -- input is required in this subunit. The
                    -- prtAlertDescription may be used to convey
                    -- a human readable description of the medium
                    -- required to satisfy the request.
                inputTrayPositionFailure(811),
                    -- The input tray failed to position
                    -- correctly.
                inputTrayElevationFailure(812),
                inputCannotFeedSizeSelected(813),
            -- Output Group
                outputMediaTrayMissing(901),
                outputMediaTrayAlmostFull(902),
                outputMediaTrayFull(903),
                outputMailboxSelectFailure(904),
            -- Marker group
                markerFuserUnderTemperature(1001),
                markerFuserOverTemperature(1002),
                markerFuserTimingFailure(1003),


Turner                 Printer MIB V2                   [Page 63]


INTERNET DRAFT          Printer MIB              January 22, 1999



                markerFuserThermistorFailure(1004),
                markerAdjustingPrintQuality(1005),
            -- Marker Supplies group
                markerTonerEmpty(1101),
                markerInkEmpty(1102),
                markerPrintRibbonEmpty(1103),
                markerTonerAlmostEmpty(1104),
                markerInkAlmostEmpty(1105),
                markerPrintRibbonAlmostEmpty(1106),
                markerWasteTonerReceptacleAlmostFull(1107),
                markerWasteInkReceptacleAlmostFull(1108),
                markerWasteTonerReceptacleFull(1109),
                markerWasteInkReceptacleFull(1110),
                markerOpcLifeAlmostOver(1111),
                markerOpcLifeOver(1112),
                markerDeveloperAlmostEmpty(1113),
                markerDeveloperEmpty(1114),
                markerTonerCartridgeMissing(1115),
            -- Media Path Device Group
                mediaPathMediaTrayMissing(1301),
                mediaPathMediaTrayAlmostFull(1302),
                mediaPathMediaTrayFull(1303),
            -- Interpreter Group
                interpreterMemoryIncreased(1501),
                interpreterMemoryDecreased(1502),
                interpreterCartridgeAdded(1503),
                interpreterCartridgeDeleted(1504),
                interpreterResourceAdded(1505),
                interpreterResourceDeleted(1506),
                interpreterResourceUnavailable(1507),
                interpreterComplexPageEncountered(1509),
                    -- The interpreter has encountered a page
                    -- that is too complex for the resources that
                    -- are available.
            -- Alert Group
                alertRemovalOfBinaryChangeEntry(1801)
                    -- A binary change event entry has been
                    -- removed from the alert table. This unary
                    -- change alert table entry is added to the
                    -- end of the alert table.
      }


-- The General Printer Group
--
-- The general printer sub-unit is responsible for the overall
-- control and status of the printer.  There is exactly one
-- general printer sub-unit in a printer.


Turner                 Printer MIB V2                   [Page 64]


INTERNET DRAFT          Printer MIB              January 22, 1999



--
-- Implementation of every object in this group is mandatory.

prtGeneral  OBJECT IDENTIFIER ::= { printmib 5 }

prtGeneralTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtGeneralEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A table of general information per printer.
        Objects in this table are defined in various
        places in the MIB, nearby the groups to
        which they apply.  They are all defined
        here to minimize the number of tables that would
        otherwise need to exist."
    ::= { prtGeneral 1 }

prtGeneralEntry OBJECT-TYPE
    SYNTAX      PrtGeneralEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
         "An entry exists in this table for each device entry in
         the host resources MIB device table with a device type
         of 'printer'"
    INDEX  { hrDeviceIndex }
    ::= { prtGeneralTable 1 }

PrtGeneralEntry ::= SEQUENCE {
    -- Note that not all of the objects in this sequence are in
    -- the general printer group. The group to which a
    -- object belongs is tagged with a label "General", "Input"
    -- "Output", etc. after each entry in the following sequence
    --
    prtGeneralConfigChanges         Counter32, -- General
    prtGeneralCurrentLocalization   Integer32, -- General
    prtGeneralReset                 PrtGeneralResetTC,
                                               -- General
    prtGeneralCurrentOperator       OCTET STRING,
                                        -- Responsible Party
    prtGeneralServicePerson         OCTET STRING,
                                        -- Responsible Party
    prtInputDefaultIndex            Integer32, -- Input
    prtOutputDefaultIndex           Integer32, -- Output
    prtMarkerDefaultIndex           Integer32, -- Marker
    prtMediaPathDefaultIndex        Integer32, -- Media Path
    prtConsoleLocalization          Integer32, -- Console


Turner                 Printer MIB V2                   [Page 65]


INTERNET DRAFT          Printer MIB              January 22, 1999



    prtConsoleNumberOfDisplayLines  Integer32, -- Console
    prtConsoleNumberOfDisplayChars  Integer32, -- Console
    prtConsoleDisable               INTEGER,   -- Console,
    prtAuxiliarySheetStartupPage    PresentOnOff,
                                               -- AuxiliarySheet
    prtAuxiliarySheetBannerPage     PresentOnOff,
                                               -- AuxiliarySheet,
    prtGeneralPrinterName           OCTET STRING,
                                               -- General
    prtGeneralSerialNumber          OCTET STRING,
                                               -- General
    prtAlertCriticalEvents          Counter32, -- Alert
    prtAlertAllEvents               Counter32  -- Alert
}

prtGeneralConfigChanges OBJECT-TYPE
    SYNTAX     Counter32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "Counts configuration changes within the printer. A
         configuration change is defined to be an action that
         results in a change to any MIB object other than those
         that reflect status or level, or those that act as
         counters or gauges. In addition, any action that results
         in a row being added or deleted from any table in the
         Printer MIB is considered a configuration change. Such
         changes will often affect the capability of the printer
         to service certain types of print jobs. Management
         applications may cache infrequently changed
         configuration information about sub-units within the
         printer. This object should be incremented whenever the
         agent wishes to notify management applications that any
         cached configuration information for this device is to
         be considered 'stale'. At this point, the management
         application should flush any configuration information
         cached about this device and fetch new configuration
         information.

         The following are examples of actions that would cause
         the prtGeneralConfigChanges object to be incremented:

         - Adding an output bin
         - Changing the media in a sensing input tray
         - Changing the value of prtInputMediaType





Turner                 Printer MIB V2                   [Page 66]


INTERNET DRAFT          Printer MIB              January 22, 1999



         Note that the prtGeneralConfigChanges counter would not
         be incremented when an input tray is removed, or the
         level of an input device changes."

    ::= { prtGeneralEntry 1 }

prtGeneralCurrentLocalization OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
          "The value of the prtLocalizationIndex corresponding to
          the current language, country, and character set to be
          used for localized string values that are identified as
          being dependent on the value of this object.  Note that
          this object does not apply to localized strings in the
          prtConsole group or to any object that is not
          explicitly identified as being localized according to
          prtGeneralCurrentLocalization."
    ::= { prtGeneralEntry 2 }

 prtGeneralReset OBJECT-TYPE
    -- This value is a type 3 enumeration
    SYNTAX     PrtGeneralResetTC
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "Setting this value to 'powerCycleReset',
         'resetToNVRAM', or 'resetToFactoryDefaults' will result
         in the resetting of the printer.  When read, this object
         will always have the value 'notResetting(3)', and a SET
         of the value 'notResetting' shall have no effect on the
         printer.  Some of the defined values are optional.
         However, every implementation must support at least the
         values 'notResetting' and 'resetToNVRAM'."
    ::= { prtGeneralEntry 3 }

-- The Responsible Party group
--
-- This group is optional.  However, to claim conformance to this
-- group, it is necessary to implement every object in the group.

prtGeneralCurrentOperator OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..127))
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION



Turner                 Printer MIB V2                   [Page 67]


INTERNET DRAFT          Printer MIB              January 22, 1999



         "The name of the person who is responsible for operating
         this printer. It is suggested that this string include
         information that would enable other humans to reach the
         operator, such as a phone number. As a convention to
         facilitate automatic notification of the operator by the
         agent or the network management station, the phone
         number, fax number or email address should be placed on
         a separate line starting with ASCII LF (hex 0x0A) and
         the ASCII text string (without the quotes): 'phone: ',
         'fax: ', and 'email: ', respectively. Phone numbers may
         contain digits, spaces and parentheses, which shall be
         ignored. Phone numbers may also include ASCII comma
         characters(hex 2C) that are used to indicate a two-
         second pause during the dialing sequence. If either the
         phone, fax, or email information is not available, then
         a line should not be included for this information.

         NOTE: For interoperability purposes, it is advisable to
         use email addresses formatted according to RFC 822
         requirements."
    ::= { prtGeneralEntry 4 }

prtGeneralServicePerson OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..127))
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The name of the person responsible for servicing this
         printer. It is suggested that this string include
         information that would enable other humans to reach the
         service person, such as a phone number. As a convention
         to facilitate automatic notification of the service
         person by the agent or a network management station, the
         phone number, fax number or email address should be
         placed on a separate line starting with ASCII LF (hex
         0x0A) and the ASCII text string (without the quotes):
         'phone: ', 'fax: ', and 'email: ', respectively. Phone
         numbers may contain digits, spaces and parentheses,
         which shall be ignored. Phone numbers can also include
         one or more ASCII comma characters(hex 2C) to indicate a
         two-second pause during the dialing sequence. If either
         the phone, fax, or email information is not available,
         then a line should not included for this information.

         NOTE: For interoperability purposes, it is advisable to
         use email addresses formatted according to RFC 822
         requirements."



Turner                 Printer MIB V2                   [Page 68]


INTERNET DRAFT          Printer MIB              January 22, 1999



    ::= { prtGeneralEntry 5 }

-- Default indexes section
--
-- The following four objects are used to specify the indexes of
-- certain subunits used as defaults during the printing process.

prtInputDefaultIndex OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The value of prtInputIndex corresponding to the default
         input sub-unit: that is, this object selects the default
         source of input media.

         This value shall be -1 if there is no default input
         subunit specified for the printer as a whole.  In this
         case, the actual default input subunit may be specified
         by means outside the scope of this MIB, such as by each
         interpreter in a printer with multiple interpreters."

    ::= { prtGeneralEntry 6 }

prtOutputDefaultIndex OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The value of prtOutputIndex corresponding to the
         default output sub-unit; that is, this object selects
         the default output destination.

         This value shall be -1 if there is no default output
         subunit specified for the printer as a whole.  In this
         case, the actual default output subunit may be specified
         by means outside the scope of this MIB, such as by each
         interpreter in a printer with multiple interpreters."

    ::= { prtGeneralEntry 7 }

prtMarkerDefaultIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The value of prtMarkerIndex corresponding to the
        default marker sub-unit; that is, this object selects the


Turner                 Printer MIB V2                   [Page 69]


INTERNET DRAFT          Printer MIB              January 22, 1999



        default marker."
    ::= { prtGeneralEntry 8 }

prtMediaPathDefaultIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The value of prtMediaPathIndex corresponding to
        the default media path; that is, the selection of the
        default media path."
    ::= { prtGeneralEntry 9 }

-- Console general section
--
-- The following four objects describe overall parameters of the
-- printer console subsystem.

prtConsoleLocalization OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The value of the prtLocalizationIndex corresponding to
         the language, country, and character set to be used for
         the console.  This localization applies both to the
         actual display on the console as well as the encoding of
         these console objects in management operations."
    ::= { prtGeneralEntry 10 }

prtConsoleNumberOfDisplayLines OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The number of lines on the printer's physical
        display.  This value is 0 if there are no lines on the
        physical display or if there is no physical display"
    ::= { prtGeneralEntry 11 }

prtConsoleNumberOfDisplayChars OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The number of characters per line displayed on the
         physical display. This value is 0 if there are no lines



Turner                 Printer MIB V2                   [Page 70]


INTERNET DRAFT          Printer MIB              January 22, 1999



         on the physical display or if there is no physical
         display"
    ::= { prtGeneralEntry 12 }

prtConsoleDisable OBJECT-TYPE
    SYNTAX     INTEGER {
                   operatorConsoleEnabled (3),
                   operatorConsoleDisabled (4),
                   operatorConsoleEnabledLevel1 (5),
                   operatorConsoleEnabledLevel2 (6),
                   operatorConsoleEnabledLevel3 (7)
               }
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "If the object prtConsoleDisable has value
         'operatorConsoleDisabled' then input is not accepted
         from the operator console. If the object
         prtConsoleDisable has the value 'operatorConsoleEnabled'
         then input is accepted from the operator console. If the
         object prtConsoleDisable has the value
         'operatorConsoleEnabledLevel1',
         'operatorConsoleEnabledLevel2' or
         'operatorConsoleEnabledLevel3' then limited input is
         accepted from the operator console; the limitations are
         product specific, however, the limitations are generally
         less restrictive for operatorConsoleEnabledLevel1 than
         for operatorConsoleEnabledLeve2, which is less
         restrictive than operatorConsoleEnabledLevel3.

         The value of the prtConsoleDisable object is a type-2
         enumeration."
    ::= { prtGeneralEntry 13 }


-- The Auxiliary Sheet Group
--
-- The auxiliary sheet group allows the administrator to control
-- the production of auxiliary sheets by the printer. This group
-- contains only the "prtAuxiliarySheetStartupPage" and
-- "prtAuxiliarySheetBannerPage" objects.
--
-- This group is optional. However, to claim conformance to this
-- group it is necessary to implement every object in the group.

prtAuxiliarySheetStartupPage OBJECT-TYPE
     SYNTAX     PresentOnOff
     MAX-ACCESS read-write


Turner                 Printer MIB V2                   [Page 71]


INTERNET DRAFT          Printer MIB              January 22, 1999



     STATUS     current
     DESCRIPTION
         "Used to enable or disable printing a startup page. If
         enabled, a startup page will be printed shortly after
         power-up, when the device is ready. Typical startup
         pages include test patterns and/or printer configuration
         information."
     ::= { prtGeneralEntry 14 }

prtAuxiliarySheetBannerPage OBJECT-TYPE
     SYNTAX     PresentOnOff
     MAX-ACCESS read-write
     STATUS     current
     DESCRIPTION
         "Used to enable or disable printing banner pages at the
         beginning of jobs. This is a master switch which applies
         to all jobs, regardless of interpreter."
     ::= { prtGeneralEntry 15 }

-- Administrative section
--
-- The following two objects are used to specify administrative
-- information assigned to the printer.

prtGeneralPrinterName OBJECT-TYPE
     SYNTAX     OCTET STRING (SIZE (0..127))
     MAX-ACCESS read-write
     STATUS     current
     DESCRIPTION
         "An administrator-specified name for this printer.
         Depending upon implementation of this printer, the value
         of this object may or may not be same as the value for
         the MIB-II 'SysName' object."
     ::= { prtGeneralEntry 16 }

prtGeneralSerialNumber OBJECT-TYPE
     SYNTAX     OCTET STRING (SIZE (0..255))
     MAX-ACCESS read-write
     STATUS     current
     DESCRIPTION
         "A recorded serial number for this device that indexes
         some type device catalog or inventory. This value is
         usually set by the device manufacturer but the MIB
         supports the option of writing for this object for site-
         specific administration of device inventory or
         tracking."
    ::= { prtGeneralEntry 17 }



Turner                 Printer MIB V2                   [Page 72]


INTERNET DRAFT          Printer MIB              January 22, 1999



-- General alert table section
--
-- The following two objects are used to specify counters
-- associated with the Alert Table.

prtAlertCriticalEvents OBJECT-TYPE
    SYNTAX     Counter32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "A running counter of the number of critical alert
         events that have been recorded in the alert table. The
         value of this object is RESET in the event of a power
         cycle operation (i.e., the value is not persistent."
    ::= { prtGeneralEntry 18 }

prtAlertAllEvents OBJECT-TYPE
    SYNTAX     Counter32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "A running counter of the total number of alert event
         entries (critical and non-critical) that have been
         recorded in the alert table"
    ::= { prtGeneralEntry 19 }


-- The Cover Table
--
-- The cover portion of the General print sub-unit describes the
-- covers and interlocks of the printer.  The Cover Table has an
-- entry for each cover and interlock.

prtCover    OBJECT IDENTIFIER ::= { printmib 6 }

prtCoverTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtCoverEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A table of the covers and interlocks of the printer."
    ::= { prtCover 1 }

prtCoverEntry OBJECT-TYPE
    SYNTAX     PrtCoverEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION


Turner                 Printer MIB V2                   [Page 73]


INTERNET DRAFT          Printer MIB              January 22, 1999



        "Information about a cover or interlock.
        Entries may exist in the table for each device
        index with a device type of 'printer'."
    INDEX  { hrDeviceIndex, prtCoverIndex }
    ::= { prtCoverTable 1 }

PrtCoverEntry ::= SEQUENCE {
    prtCoverIndex            Integer32,
    prtCoverDescription      OCTET STRING,
    prtCoverStatus           PrtCoverStatusTC
}

prtCoverIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "A unique value used by the printer to identify this
         Cover sub-unit.  Although these values may change due to
         a major reconfiguration of the device (e.g. the addition
         of new cover sub-units to the printer), values are
         expected to remain stable across successive printer
         power cycles."
    ::= { prtCoverEntry 1 }

prtCoverDescription OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..255))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The manufacturer provided cover sub-mechanism name in
         the localization specified by
         prtGeneralCurrentLocalization."
    ::= { prtCoverEntry 2 }

prtCoverStatus  OBJECT-TYPE
    --  This value is a type 2 enumeration
    SYNTAX     PrtCoverStatusTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The status of this cover sub-unit."
    ::= { prtCoverEntry 3 }

-- The Localization Table
--
-- The localization portion of the General printer sub-unit is
-- responsible for identifying the natural language, country, and


Turner                 Printer MIB V2                   [Page 74]


INTERNET DRAFT          Printer MIB              January 22, 1999



-- character set in which character strings are expressed. There
-- may be one or more localizations supported per printer. The
-- available localizations are represented by the Localization
-- table.

prtLocalization  OBJECT IDENTIFIER ::= { printmib 7 }

prtLocalizationTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtLocalizationEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "The available localizations in this printer."
    ::= { prtLocalization 1 }

prtLocalizationEntry OBJECT-TYPE
    SYNTAX     PrtLocalizationEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A description of a localization.
        Entries may exist in the table for each device
        index with a device type of 'printer'."
    INDEX  { hrDeviceIndex, prtLocalizationIndex }
    ::= { prtLocalizationTable 1 }

PrtLocalizationEntry ::= SEQUENCE {
        prtLocalizationIndex          Integer32,
        prtLocalizationLanguage       DisplayString,
        prtLocalizationCountry        DisplayString,
        prtLocalizationCharacterSet   CodedCharSet
}

prtLocalizationIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "A unique value used by the printer to identify this
         localization entry.  Although these values may change
         due to a major reconfiguration of the device (e.g., the
         addition of new localization data to the printer),
         values are expected to remain stable across successive
         printer power cycles."
    ::= { prtLocalizationEntry 1 }

prtLocalizationLanguage OBJECT-TYPE
    SYNTAX     DisplayString (SIZE(0..2))


Turner                 Printer MIB V2                   [Page 75]


INTERNET DRAFT          Printer MIB              January 22, 1999



    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "A two character language code from ISO 639.  Examples
         en, gb, ca, fr, de."
    ::= { prtLocalizationEntry 2 }

prtLocalizationCountry OBJECT-TYPE
    SYNTAX     DisplayString (SIZE(0..2))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "A two character country code from ISO 3166, a blank
         string (two space characters) shall indicate that the
         country is not defined.  Examples: US, FR, DE, ..."
    ::= { prtLocalizationEntry 3 }

prtLocalizationCharacterSet OBJECT-TYPE
    SYNTAX     CodedCharSet
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
      "The coded character set used for this localization."
    ::= { prtLocalizationEntry 4 }

-- The System Resources Tables
--
-- The Printer MIB makes use of the Host Resources MIB to
-- define system resources by referencing the storage
-- and device groups of the print group.  In order to
-- determine, amongst multiple printers serviced by
-- one agent, which printer owns a particular resource,
-- the prtStorageRef and prtDeviceRef tables associate
-- particular storage and device entries to printers.

prtStorageRefTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtStorageRefEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        ""
    ::= { prtGeneral 2 }

prtStorageRefEntry OBJECT-TYPE
    SYNTAX     PrtStorageRefEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION


Turner                 Printer MIB V2                   [Page 76]


INTERNET DRAFT          Printer MIB              January 22, 1999



         "This table will have an entry for each entry in the
         Host Resources MIB storage table that represents storage
         associated with a printer managed by this agent."
    INDEX      { hrStorageIndex, prtStorageRefSeqNumber }
    ::= { prtStorageRefTable 1 }

PrtStorageRefEntry ::= SEQUENCE {
    prtStorageRefSeqNumber  Integer32,
    prtStorageRefIndex      Integer32
}

prtStorageRefSeqNumber OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "This value will be unique amongst all entries with a
         common value of hrStorageIndex. This object allows a
         storage entry to point to the multiple printer devices
         with which it is associated."

    ::= { prtStorageRefEntry 1 }

prtStorageRefIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The value of the hrDeviceIndex of the printer device
         that this storageEntry is associated with."
    ::= { prtStorageRefEntry 2 }

prtDeviceRefTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtDeviceRefEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        ""
    ::= { prtGeneral 3 }

prtDeviceRefEntry OBJECT-TYPE
    SYNTAX     PrtDeviceRefEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "This table will have an entry for each entry in the
         Host Resources MIB device table that represents a device
         associated with a printer managed by this agent."


Turner                 Printer MIB V2                   [Page 77]


INTERNET DRAFT          Printer MIB              January 22, 1999



    INDEX      { hrDeviceIndex, prtDeviceRefSeqNumber }
    ::= { prtDeviceRefTable 1 }

PrtDeviceRefEntry ::= SEQUENCE {
    prtDeviceRefSeqNumber   Integer32,
    prtDeviceRefIndex       Integer32
}

prtDeviceRefSeqNumber OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "This value will be unique amongst all entries with a
         common value of hrDeviceIndex. This object allows a
         device entry to point to the multiple printer devices
         with which it is associated."
    ::= { prtDeviceRefEntry 1 }

prtDeviceRefIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The value of the hrDeviceIndex of the printer device
         that this deviceEntry is associated with."
    ::= { prtDeviceRefEntry 2 }


-- The Input Group
--
-- Input sub-units are managed as a tabular, indexed collection
-- of possible devices capable of providing media for input to
-- the printing process. Input sub-units typically have a
-- location, a type, an identifier, a set of constraints on
-- possible media sizes and potentially other media
-- characteristics, and may be capable of indicating current
-- status or capacity.
--
-- Implementation of every object in this group is mandatory.


prtInput   OBJECT IDENTIFIER ::= { printmib 8 }


prtInputTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtInputEntry
    MAX-ACCESS not-accessible


Turner                 Printer MIB V2                   [Page 78]


INTERNET DRAFT          Printer MIB              January 22, 1999



    STATUS     current
    DESCRIPTION
         "A table of the devices capable of providing media for
         input to the printing process."
    ::= { prtInput 2 }

prtInputEntry OBJECT-TYPE
    SYNTAX     PrtInputEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "Attributes of a device capable of providing media for
         input to the printing process. Entries may exist in the
         table for each device index with a device type of
         'printer'."
    INDEX  { hrDeviceIndex, prtInputIndex }
    ::= { prtInputTable 1 }

PrtInputEntry ::= SEQUENCE {
        prtInputIndex                     Integer32,
        prtInputType                      PrtInputTypeTC,
        prtInputDimUnit                   PrtMediaUnitTC,
        prtInputMediaDimFeedDirDeclared   Integer32,
        prtInputMediaDimXFeedDirDeclared  Integer32,
        prtInputMediaDimFeedDirChosen     Integer32,
        prtInputMediaDimXFeedDirChosen    Integer32,
        prtInputCapacityUnit              PrtCapacityUnitTC,
        prtInputMaxCapacity               Integer32,
        prtInputCurrentLevel              Integer32,
        prtInputStatus                    PrtSubUnitStatusTC,
        prtInputMediaName                 OCTET STRING,
        prtInputName                      OCTET STRING,
        prtInputVendorName                OCTET STRING,
        prtInputModel                     OCTET STRING,
        prtInputVersion                   OCTET STRING,
        prtInputSerialNumber              OCTET STRING,
        prtInputDescription               OCTET STRING,
        prtInputSecurity                  PresentOnOff,
        prtInputMediaWeight               Integer32,
        prtInputMediaType                 OCTET STRING,
        prtInputMediaColor                OCTET STRING,
        prtInputMediaFormParts            Integer32,
        prtInputMediaLoadTimeout          Integer32,
        prtInputNextIndex                 Integer32
}

prtInputIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)


Turner                 Printer MIB V2                   [Page 79]


INTERNET DRAFT          Printer MIB              January 22, 1999



    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "A unique value used by the printer to identify this
         input sub-unit. Although these values may change due to
         a major reconfiguration of the device (e.g. the addition
         of n input sub-units to the printer), values are
         expected to remain stable across successive printer
         power cycles."
    ::= { prtInputEntry 1 }

prtInputType OBJECT-TYPE
    SYNTAX     PrtInputTypeTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The type of technology (discriminated primarily
         according to feeder mechanism type) employed by the
         input sub-unit.  Note, the Optional Input Class provides
         for a descriptor field to further qualify the other
         choice."
    ::= { prtInputEntry 2 }

prtInputDimUnit OBJECT-TYPE
    SYNTAX     PrtMediaUnitTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The unit of measurement for use calculating and relaying
         dimensional values for this input sub-unit."
    ::= { prtInputEntry 3 }

prtInputMediaDimFeedDirDeclared OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "This object provides the value of the declared
         dimension, in the feed direction, of the media that is
         (or, if empty, was or will be) in this input sub-unit.
         The feed direction is the direction in which the media
         is fed on this sub-unit.  This dimension is measured in
         input sub-unit dimensional units (prtInputDimUnit).  If
         this input sub-unit can reliably sense this value, the
         value is sensed by the printer and may not be changed by
         management requests.  Otherwise, the value may be
         changed. The value (-1) means other and specifically



Turner                 Printer MIB V2                   [Page 80]


INTERNET DRAFT          Printer MIB              January 22, 1999



         means that this sub-unit places no restriction on this
         parameter.

         The value (-2) indicates unknown."
    ::= { prtInputEntry 4 }

prtInputMediaDimXFeedDirDeclared OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "This object provides the value of the declared
         dimension, in the cross feed direction, of the media
         that is (or, if empty, was or will be) in this input
         sub-unit.  The cross  feed direction is ninety degrees
         relative to the feed direction associated with this sub-
         unit. This dimension is measured in input sub-unit
         dimensional units (prtInputDimUnit).  If this input sub-
         unit can reliably sense this value, the value is sensed
         by the printer and may not be changed by management
         requests. Otherwise, the value may be changed. The value
         (-1) means other and specifically means that this sub-
         unit places no restriction on this parameter. The value
         (-2) indicates unknown."
    ::= { prtInputEntry 5 }

prtInputMediaDimFeedDirChosen OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The printer will act as if media of the chosen
         dimension (in the feed direction) is present in this
         input source.  Note that this value will be used even if
         the input tray is empty. Feed dimension measurements are
         taken relative to the feed direction associated with
         that sub-unit and are in input sub-unit dimensional
         units (MediaUnit). If the printer supports the declared
         dimension, the granted dimension is the same as the
         declared dimension. If not, the granted dimension is set
         to the closest dimension that the printer supports when
         the declared dimension is set. The value (-1) means
         other and specifically indicates that this sub-unit
         places no restriction on this parameter. The value (-2)
         indicates unknown."
    ::= { prtInputEntry 6 }

prtInputMediaDimXFeedDirChosen OBJECT-TYPE


Turner                 Printer MIB V2                   [Page 81]


INTERNET DRAFT          Printer MIB              January 22, 1999



    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The printer will act as if media of the chosen
         dimension (in the cross feed direction) is present in
         this input source. Note that this value will be used
         even if the input tray is empty.  The cross feed
         direction is ninety degrees relative to the feed
         direction associated with this sub-unit. This dimension
         is measured in input sub-unit dimensional units
         (MediaUnit).  If the printer supports the declare
         dimension, the granted dimension is the same as the
         declared dimension. If not, the granted dimension is set
         to the closest dimension that the printer supports when
         the declared dimension is set. The value (-1) means
         other and specifically indicates that this sub-unit
         places no restriction on this parameter.  The value (-2)
         indicates unknown."
    ::= { prtInputEntry 7 }

prtInputCapacityUnit OBJECT-TYPE
    SYNTAX     PrtCapacityUnitTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The unit of measurement for use in calculating and
         relaying capacity values for this input sub-unit."
    ::= { prtInputEntry 8 }

prtInputMaxCapacity OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The maximum capacity of the input sub-unit in input
         sub-unit capacity units (PrtCapacityUnitTC).  There is
         no convention associated with the media itself so this
         value reflects claimed capacity. If this input sub-unit
         can reliably sense this value, the value is sensed by
         the printer and may not be changed by management
         requests; otherwise, the value may be written (by a
         Remote Control Panel or a Management Application). The
         value (-1) means other and specifically indicates that
         the sub-unit places no restrictions on this parameter.
         The value (-2) means unknown."
    ::= { prtInputEntry 9 }



Turner                 Printer MIB V2                   [Page 82]


INTERNET DRAFT          Printer MIB              January 22, 1999



prtInputCurrentLevel OBJECT-TYPE
    SYNTAX     Integer32 --    in capacity units
                         --   (PrtCapacityUnitTC).
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The current capacity of the input sub-unit in input
         sub-unit capacity units (PrtCapacityUnitTC). If this
         input sub-unit can reliably sense this value, the value
         is sensed by the printer and may not be changed by
         management requests; otherwise, the value may be written
         (by a Remote Control Panel or a Management Application).
         The value (-1) means other and specifically indicates
         that the sub-unit places no restrictions on this
         parameter. The value (-2) means unknown. The value (-3)
         means that the printer knows that at least one unit
         remains."
    ::= { prtInputEntry 10 }

prtInputStatus OBJECT-TYPE
    SYNTAX     PrtSubUnitStatusTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The current status of this input sub-unit."
    ::= { prtInputEntry 11 }

prtInputMediaName OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "A description of the media contained in this input sub-
         unit; This description is intended for display to a
         human operator. This description is not processed by the
         printer.  It is used to provide information not
         expressible in terms of the other media attributes (e.g.
         prtInputMediaDimFeedDirChosen,
         prtInputMediaDimXFeedDirChosen, prtInputMediaWeight,
         prtInputMediaType). An example would be 'legal tender
         bond paper'."
    REFERENCE
         "See Appendix C, 'Media Names'."
    ::= { prtInputEntry 12 }






Turner                 Printer MIB V2                   [Page 83]


INTERNET DRAFT          Printer MIB              January 22, 1999



--             INPUT MEASUREMENT
--
--     _______ |               |
--      ^      |               |
--      |      |               |                 |
--      |      |_ _ _ _ _ _ _ _| _______________ |direction
--      |      |               |      ^          v
-- MaxCapacity |    Sheets     |      |
--      |      |     left      | CurrentLevel
--      |      |      in       |      |
--      v      |     tray      |      v
--     _______ +_______________+ _______


-- The Extended Input Group
--
-- This group is optional.  However, to claim conformance to this
-- group, it is necessary to implement every object in the group.


prtInputName OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The name assigned to this input sub-unit."
    ::= { prtInputEntry 13 }

prtInputVendorName OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The vendor name of this input sub-unit."
    ::= { prtInputEntry 14 }

prtInputModel OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The model name of this input sub-unit."
    ::= { prtInputEntry 15 }

prtInputVersion OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-only
    STATUS     current


Turner                 Printer MIB V2                   [Page 84]


INTERNET DRAFT          Printer MIB              January 22, 1999



    DESCRIPTION
        "The version of this input sub-unit."
    ::= { prtInputEntry 16 }

prtInputSerialNumber OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The serial number assigned to this input sub-unit."
    ::= { prtInputEntry 17 }

prtInputDescription OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..255))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "A free-form text description of this input sub-unit in
         the localization specified by
         prtGeneralCurrentLocalization."
    ::= { prtInputEntry 18 }

prtInputSecurity OBJECT-TYPE
    SYNTAX     PresentOnOff
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "Indicates if this input sub-unit has some security
         associated with it."
    ::= { prtInputEntry 19 }

-- The Input Media Group
--
-- The Input Media Group supports identification of media
-- installed or available for use on a printing device.
-- Medium resources are identified by name, and include a
-- collection of characteristic attributes that may further be
-- used for selection and management of them.
-- The Input Media group consists of a set of optional
-- "columns" in the Input Table. In this manner, a minimally
-- conforming implementation may choose to not support reporting
-- of media resources if it cannot do so.
--
-- This group is optional.  However, to claim conformance to this
-- group, it is necessary to implement every object in the group.

prtInputMediaWeight  OBJECT-TYPE
    SYNTAX     Integer32


Turner                 Printer MIB V2                   [Page 85]


INTERNET DRAFT          Printer MIB              January 22, 1999



    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The weight of the medium associated with this input
         sub-unit in grams / per meter squared. The value (-2)
         means unknown."
    ::= { prtInputEntry 20 }

prtInputMediaType OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The name of the type of medium associated with this
         input sub-unit. This name need not be processed by the
         printer; it might simply be displayed to an operator.
         The standardized string values from ISO 10175 (DPA) and
         ISO 10180 (SPDL) are:

         stationery       Separately cut sheets of an opaque
                          material
         transparency     Separately cut sheets of a transparent
                          material
         envelope         Envelopes that can be used for
                          conventional mailing purposes
         envelope-plain   Envelopes that are not preprinted and
                          have no windows
         envelope-window  Envelopes that have windows for
                          addressing purposes
         continuous-long  Continuously connected sheets of an
                          opaque material connected along the
                          long edge
         continuous-short Continuously connected sheets of an
                          opaque material connected along the
                          short edge
         tab-stock        Media with tabs
         multi-part-form  Form medium composed of multiple layers
                          not pre-attached to one another; each
                          sheet may be drawn separately from an
                          input source
         labels           Label stock
         multi-layer      Form medium composed of multiple layers
                          which are pre-attached to one another;
                          e.g., for use with impact printers.

         Implementers may add additional string values. The
         naming



Turner                 Printer MIB V2                   [Page 86]


INTERNET DRAFT          Printer MIB              January 22, 1999



         conventions in ISO 9070 are recommended in order to
         avoid
         potential name clashes."
    ::= { prtInputEntry 21 }

prtInputMediaColor OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The name of the color of the medium associated with
        this input sub-unit using standardized string values
        from ISO 10175 (DPA) and ISO 10180 (SPDL) which are:

        other
        unknown
        white
        pink
        yellow
        buff
        goldenrod
        blue
        green
        transparent

        Implementers may add additional string values. The naming
        conventions in ISO 9070 are recommended in order to avoid
        potential name clashes."
    ::= { prtInputEntry 22 }

prtInputMediaFormParts OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The number of parts associated with the medium
         associated with this input sub-unit if the medium is a
         multi-part form.  The value (-1) means other and
         specifically indicates that the device places no
         restrictions on this parameter.  The value (-2) means
         unknown."
    ::= { prtInputEntry 23 }

-- The Input Switching Group
--
-- The input switching group allows the administrator to set the
-- input subunit time-out for the printer and to control the
-- automatic input subunit switching by the printer when an input


Turner                 Printer MIB V2                   [Page 87]


INTERNET DRAFT          Printer MIB              January 22, 1999



-- subunit becomes empty.
--
-- This group is optional. However, to claim conformance to this
-- group, it is required to implement every object in the group.

prtInputMediaLoadTimeout OBJECT-TYPE
   SYNTAX     Integer32
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
         "When the printer is not able to print due to a subunit
         being empty or the requested media must be manually
         loaded, the printer will wait for the duration (in
         seconds) specified by this object. Upon expiration of
         the time-out, the printer will take the action specified
         by prtInputNextIndex.

         The event which causes the printer to enter the waiting
         state is product specific. If the printer is not waiting
         for manually fed media, it may switch from an empty
         subunit to a different subunit without waiting for the
         time-out to expire.

         A value of (-1) implies 'other' or 'infinite' which
         translates to 'wait forever'. The action which causes
         printing to continue is product specific. A value of (-
         2) implies 'unknown'."

   ::= { prtInputEntry 24 }

prtInputNextIndex OBJECT-TYPE
   SYNTAX     Integer32
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
         "The value of prtInputIndex corresponding to the input
         subunit which will be used when this input subunit is
         emptied and the time-out specified by
         prtInputMediaLoadTimeout expires. A value of zero(0)
         indicates that auto input switching will not occur when
         this input subunit is emptied. If the time-out specified
         by prtInputLoadMediaTimeout expires and this value is
         zero(0), the job will be aborted. A value of (-1) means
         other. The value (-2) means 'unknown' and specifically
         indicates that an implementation specific method will
         determine the next input subunit to use at the time this
         subunit is emptied and the time-out expires. The value(-



Turner                 Printer MIB V2                   [Page 88]


INTERNET DRAFT          Printer MIB              January 22, 1999



         3) means input switching is not supported for this
         subunit."
   ::= { prtInputEntry 25 }

-- The Output Group
--
-- Output sub-units are managed as a tabular, indexed collection
-- of possible devices capable of receiving media delivered from
-- the printing process.  Output sub-units typically have a
-- location, a type, an identifier, a set of constraints on
-- possible media sizes and potentially other characteristics,
-- and may be capable of indicating current status or capacity.
--
-- Implementation of every object in this group is mandatory.

prtOutput  OBJECT IDENTIFIER ::= { printmib 9 }


prtOutputTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtOutputEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "A table of the devices capable of receiving media
         delivered from the printing process."
    ::= { prtOutput 2 }

prtOutputEntry OBJECT-TYPE
    SYNTAX     PrtOutputEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "Attributes of a device capable of receiving media
         delivered from the printing process. Entries may exist
         in the table for each device index with a device type of
         'printer'."
    INDEX  { hrDeviceIndex, prtOutputIndex }
    ::= { prtOutputTable 1 }

PrtOutputEntry ::= SEQUENCE {
        prtOutputIndex                    Integer32,
        prtOutputType                     PrtOutputTypeTC,
        prtOutputCapacityUnit             PrtCapacityUnitTC,
        prtOutputMaxCapacity              Integer32,
        prtOutputRemainingCapacity        Integer32,
        prtOutputStatus                   PrtSubUnitStatusTC,
        prtOutputName                     OCTET STRING,
        prtOutputVendorName               OCTET STRING,


Turner                 Printer MIB V2                   [Page 89]


INTERNET DRAFT          Printer MIB              January 22, 1999



        prtOutputModel                    OCTET STRING,
        prtOutputVersion                  OCTET STRING,
        prtOutputSerialNumber             OCTET STRING,
        prtOutputDescription              OCTET STRING,
        prtOutputSecurity                 PresentOnOff,
        prtOutputDimUnit                  PrtMediaUnitTC,
        prtOutputMaxDimFeedDir            Integer32,
        prtOutputMaxDimXFeedDir           Integer32,
        prtOutputMinDimFeedDir            Integer32,
        prtOutputMinDimXFeedDir           Integer32,
        prtOutputStackingOrder        PrtOutputStackingOrderTC,
        prtOutputPageDeliveryOrientation
                            PrtOutputPageDeliveryOrientationTC,
        prtOutputBursting                 PresentOnOff,
        prtOutputDecollating              PresentOnOff,
        prtOutputPageCollated             PresentOnOff,
        prtOutputOffsetStacking           PresentOnOff
}

prtOutputIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A unique value used by this printer to identify this
        output sub-unit. Although these values may change due
        to a major reconfiguration of the sub-unit (e.g.  the
        addition of new output devices to the printer), values
        are expected to remain stable across successive printer
        power cycles."
    ::= { prtOutputEntry 1 }

prtOutputType OBJECT-TYPE
    -- This value is a type 2 enumeration
    SYNTAX     PrtOutputTypeTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The type of technology supported by this output sub-
         unit."
    ::= { prtOutputEntry 2 }

prtOutputCapacityUnit OBJECT-TYPE
    SYNTAX     PrtCapacityUnitTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION



Turner                 Printer MIB V2                   [Page 90]


INTERNET DRAFT          Printer MIB              January 22, 1999



         "The unit of measurement for use in calculating and
         relaying capacity values for this output sub-unit."
    ::= { prtOutputEntry 3 }

prtOutputMaxCapacity OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The maximum capacity of this output sub-unit in output
         sub-unit capacity units (PrtCapacityUnitTC). There is no
         convention associated with the media itself so this
         value essentially reflects claimed capacity. If this
         output sub-unit can reliably sense this value, the value
         is sensed by the printer and may not be changed by
         management requests; otherwise, the value may be written
         (by a Remote Control Panel or a Management Application).
         The value (-1) means other and specifically indicates
         that the sub-unit places no restrictions on this
         parameter. The value (-2) means unknown."
    ::= { prtOutputEntry 4 }

prtOutputRemainingCapacity OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The remaining capacity of the possible output sub-unit
         capacity in output sub-unit capacity units
         (PrtCapacityUnitTC)of this output sub-unit. If this
         output sub-unit can reliably sense this value, the value
         is sensed by the printer and may not be modified by
         management requests; otherwise, the value may be written
         (by a Remote Control Panel or a Management Application).
         The value (-1) means other and specifically indicates
         that the sub-unit places no restrictions on this
         parameter.  The value (-2) means unknown.  The value (-
         3) means that the printer knows that there remains
         capacity for at least one unit."
    ::= { prtOutputEntry 5 }

prtOutputStatus OBJECT-TYPE
    SYNTAX     PrtSubUnitStatusTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The current status of this output sub-unit."
    ::= { prtOutputEntry 6 }


Turner                 Printer MIB V2                   [Page 91]


INTERNET DRAFT          Printer MIB              January 22, 1999





--            OUTPUT MEASUREMENT
--
--   _______  |                | ________
--      ^     |                |     ^
--      |     |                |     |
--      |     |                |RemainingCapacity
-- MaxCapacity|                |     |
--      |     |                |     v           ^
--      |     |_ _ _ _ _ _ _ _ | _______________ |direction
--      |     |    Sheets      |                 |
--      |     |      in        |
--      v     |    Output      |
--   _______  +________________+


-- The Extended Output Group
--
-- This group is optional.  However, to claim conformance to this
-- group, it is necessary to implement every object in the group.

prtOutputName OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The name assigned to this output sub-unit."
    ::= { prtOutputEntry 7 }

prtOutputVendorName OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The vendor name of this output sub-unit."
    ::= { prtOutputEntry 8 }

prtOutputModel OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The model name assigned to this output sub-unit."
    ::= { prtOutputEntry 9 }

prtOutputVersion OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))


Turner                 Printer MIB V2                   [Page 92]


INTERNET DRAFT          Printer MIB              January 22, 1999



    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The version of this output sub-unit."
    ::= { prtOutputEntry 10 }

prtOutputSerialNumber OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The serial number assigned to this output sub-unit."
    ::= { prtOutputEntry 11 }

prtOutputDescription OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..255))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "A free-form text description of this output sub-unit in
         the localization specified by
         prtGeneralCurrentLocalization."
    ::= { prtOutputEntry 12 }

prtOutputSecurity OBJECT-TYPE
    SYNTAX     PresentOnOff
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "Indicates if this output sub-unit has some security
         associated with it and if that security is enabled or
         not."
    ::= { prtOutputEntry 13 }

-- The Output Dimensions Group
--
-- This group is optional.  However, to claim conformance to this
-- group, it is necessary to implement every object in the group.

prtOutputDimUnit OBJECT-TYPE
    SYNTAX     PrtMediaUnitTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The unit of measurement for use in calculating and
         relaying dimensional values for this output sub-unit."
    ::= { prtOutputEntry 14 }



Turner                 Printer MIB V2                   [Page 93]


INTERNET DRAFT          Printer MIB              January 22, 1999



prtOutputMaxDimFeedDir OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The maximum dimensions supported by this output sub-unit
        for measurements taken parallel relative to the feed
        direction associated with that sub-unit in output
        sub-unit dimensional units (MediaUnit). If this output
        sub-unit can reliably sense this value, the value is
        sensed by the printer and may not be changed with
        management protocol operations."
    ::= { prtOutputEntry 15 }

prtOutputMaxDimXFeedDir OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The maximum dimensions supported by this output sub-unit
        for measurements taken ninety degrees relative to the
        feed direction associated with that sub-unit in output
        sub-unit dimensional units (MediaUnit). If this output
        sub-unit can reliably sense this value, the value is
        sensed by the printer and may not be changed with
        management protocol operations."
    ::= { prtOutputEntry 16 }

prtOutputMinDimFeedDir OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The minimum dimensions supported by this output sub-unit
        for measurements taken parallel relative to the feed
        direction associated with that sub-unit in output
        sub-unit dimensional units (DimUnit).  If this output
        sub-unit can reliably sense this value, the value is
        sensed by the printer and may not be changed with
        management protocol operations."
    ::= { prtOutputEntry 17 }

prtOutputMinDimXFeedDir OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The minimum dimensions supported by this output sub-unit


Turner                 Printer MIB V2                   [Page 94]


INTERNET DRAFT          Printer MIB              January 22, 1999



        for measurements taken ninety degrees relative to the
        feed direction associated with that sub-unit in output
        sub-unit dimensional units (DimUnit). If this output
        sub-unit can reliably sense this value, the value is
        sensed by the printer and may not be changed with
        management protocol operations."
    ::= { prtOutputEntry 18 }

-- The Output Features Group
--
-- This group is optional.  However, to claim conformance to this
-- group, it is necessary to implement every object in the group.

prtOutputStackingOrder OBJECT-TYPE
    --  This value is a type 1 enumeration
    SYNTAX     PrtOutputStackingOrderTC
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The current state of the stacking order for the
        associated output sub-unit. 'FirstToLast' means
        that as pages are output the front of the next page is
        placed against the back of the previous page.
        'LasttoFirst' means that as pages are output the back
        of the next page is placed against the front of the
        previous page."
    ::= { prtOutputEntry 19 }

prtOutputPageDeliveryOrientation OBJECT-TYPE
    --   This value is a type 1 enumeration
    SYNTAX     PrtOutputPageDeliveryOrientationTC
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
        "The reading surface that will be 'up' when pages are
        delivered to the associated output sub-unit. Values are
        faceUp and faceDown. (Note: interpretation of these
        values is in general context-dependent based on locale;
        presentation of these values to an end-user should be
        normalized to the expectations of the user)."
    ::= { prtOutputEntry 20 }

prtOutputBursting OBJECT-TYPE
    SYNTAX     PresentOnOff
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION



Turner                 Printer MIB V2                   [Page 95]


INTERNET DRAFT          Printer MIB              January 22, 1999



         "This object indicates that the outputting sub-unit
         supports bursting, and if so, whether the feature is
         enabled. Bursting is the process by which continuous
         media is separated into individual sheets, typically by
         bursting along pre-formed perforations."
    ::= { prtOutputEntry 21 }

prtOutputDecollating OBJECT-TYPE
    SYNTAX     PresentOnOff
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "This object indicates that the output supports
         decollating, and if so, whether the feature is enabled.
         Decollating is the process by which the individual parts
         within a multi-part form are separated and sorted into
         separate stacks for each part."
    ::= { prtOutputEntry 22 }

prtOutputPageCollated OBJECT-TYPE
    SYNTAX     PresentOnOff
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "This object indicates that the output sub-unit supports
         page collation, and if so, whether the feature is
         enabled. See glossary for definition of how this
         document defines collation."
    ::= { prtOutputEntry 23 }

prtOutputOffsetStacking OBJECT-TYPE
    SYNTAX     PresentOnOff
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "This object indicates that the output supports offset
         stacking, and if so, whether the feature is enabled. See
         glossary for how Offset Stacking is defined by this
         document."
    ::= { prtOutputEntry 24 }

-- The Marker Group
--
-- A marker is the mechanism that produces marks on the print
-- media. The marker sub-units and their associated supplies are
-- represented by the Marker Group in the model.  A printer can
-- contain one or more marking mechanisms.  Some examples of
-- multiple marker sub-units are: a printer


Turner                 Printer MIB V2                   [Page 96]


INTERNET DRAFT          Printer MIB              January 22, 1999



-- with separate markers for normal and magnetic ink or an
-- imagesetter that can output to both a proofing device and
-- final film. Each marking device can have its own set of
-- characteristics associated with it, such as marking technology
-- and resolution.
--
-- Implementation of every object in this group is mandatory.


prtMarker OBJECT IDENTIFIER ::= { printmib 10 }


-- The printable area margins as listed below define an area of
-- the print media which is guaranteed to be printable for all
-- combinations of input, media paths, and interpreters for this
-- marker.

prtMarkerTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtMarkerEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        ""
    ::= { prtMarker 2 }

prtMarkerEntry OBJECT-TYPE
    SYNTAX     PrtMarkerEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "Entries may exist in the table for each device index
         with a device type of 'printer'."
    INDEX  { hrDeviceIndex, prtMarkerIndex }
    ::= { prtMarkerTable 1 }

PrtMarkerEntry ::= SEQUENCE {
        prtMarkerIndex                  Integer32,
        prtMarkerMarkTech               PrtMarkerMarkTechTC,
        prtMarkerCounterUnit            PrtMarkerCounterUnitTC,
        prtMarkerLifeCount              Counter32,
        prtMarkerPowerOnCount           Counter32,
        prtMarkerProcessColorants       Integer32,
        prtMarkerSpotColorants          Integer32,
        prtMarkerAddressabilityUnit     INTEGER,
        prtMarkerAddressabilityFeedDir  Integer32,
        prtMarkerAddressabilityXFeedDir Integer32,
        prtMarkerNorthMargin            Integer32,
        prtMarkerSouthMargin            Integer32,


Turner                 Printer MIB V2                   [Page 97]


INTERNET DRAFT          Printer MIB              January 22, 1999



        prtMarkerWestMargin             Integer32,
        prtMarkerEastMargin             Integer32,
        prtMarkerStatus                 PrtSubUnitStatusTC
}


prtMarkerIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "A unique value used by the printer to identify this
         marking SubUnit.  Although these values may change due
         to a major reconfiguration of the device (e.g. the
         addition of new marking sub-units to the printer),
         values are expected to remain stable across successive
         printer power cycles."
    ::= { prtMarkerEntry 1 }

prtMarkerMarkTech OBJECT-TYPE
    -- This value is a type 2 enumeration
    SYNTAX     PrtMarkerMarkTechTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The type of marking technology used for this marking
         sub-unit."
    ::= { prtMarkerEntry 2 }

prtMarkerCounterUnit OBJECT-TYPE
    -- This value is a type 1 enumeration
    SYNTAX     PrtMarkerCounterUnitTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The unit that will be used by the printer when
         reporting counter values for this marking sub-unit.  The
         time units of measure are provided for a device like a
         strip recorder that does not or cannot track the
         physical dimensions of the media and does not use
         characters, lines or sheets."
    ::= { prtMarkerEntry 3}

prtMarkerLifeCount OBJECT-TYPE
    SYNTAX     Counter32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION


Turner                 Printer MIB V2                   [Page 98]


INTERNET DRAFT          Printer MIB              January 22, 1999



         "The count of the number of units of measure counted
         during the life of printer using units of measure as
         specified by prtMarkerCounterUnit."
    ::= { prtMarkerEntry 4 }

prtMarkerPowerOnCount OBJECT-TYPE
    SYNTAX     Counter32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The count of the number of units of measure counted
         since the equipment was most recently powered on using
         units of measure as specified by prtMarkerCounterUnit."
    ::= { prtMarkerEntry 5 }

prtMarkerProcessColorants OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The number of process colors supported by this marker.
         A process color of 1 implies monochrome.  The value of
         this object and prtMarkerSpotColorants cannot both be 0.
         The value of prtMarkerProcessColorants must be 0 or
         greater."
    ::= { prtMarkerEntry 6 }

prtMarkerSpotColorants OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The number of spot colors supported by this marker. The
         value of this object and prtMarkerProcessColorants
         cannot both be 0.  Must be 0 or greater."
    ::= { prtMarkerEntry 7 }

prtMarkerAddressabilityUnit OBJECT-TYPE
    --   This value is a type 1 enumeration
    SYNTAX     INTEGER {
                   tenThousandthsOfInches(3),  -- .0001
                   micrometers(4)
               }
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The unit of measure of distances, as applied to the
         marker's resolution."


Turner                 Printer MIB V2                   [Page 99]


INTERNET DRAFT          Printer MIB              January 22, 1999



    ::= { prtMarkerEntry 8 }

prtMarkerAddressabilityFeedDir OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The maximum number of addressable marking positions in
         the feed direction per 10000 units of measure specified
         by prtMarkerAddressabilityUnit.  A value of (-1) implies
         'other' or 'infinite' while a value of (-2) implies
         'unknown'."
    ::= { prtMarkerEntry 9 }

prtMarkerAddressabilityXFeedDir OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The maximum number of addressable marking positions in
         the cross feed direction in 10000 units of measure
         specified by prtMarkerAddressabilityUnit.  A value of (-
         1) implies 'other' or 'infinite' while a value of (-2)
         implies 'unknown'."
    ::= { prtMarkerEntry 10 }

prtMarkerNorthMargin OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The margin, in units identified by
         prtMarkerAddressabilityUnit, from the leading edge of
         the medium as the medium flows through the marking
         engine with the side to be imaged facing the observer.
         The leading edge is the North edge and the other edges
         are defined by the normal compass layout of  directions
         with the compass facing the observer.  Printing within
         the area bounded by all four margins is guaranteed for
         all interpreters.   The value (-2) means unknown."
    ::= { prtMarkerEntry 11 }

prtMarkerSouthMargin OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION



Turner                 Printer MIB V2                  [Page 100]


INTERNET DRAFT          Printer MIB              January 22, 1999



         "The margin from the South edge  (see
         prtMarkerNorthMargin) of the medium in units identified
         by prtMarkerAddressabilityUnit.  Printing within the
         area bounded by all four margins  is guaranteed for all
         interpreters. The value (-2) means unknown."
    ::= { prtMarkerEntry 12 }

prtMarkerWestMargin OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The margin from the West edge (see
         prtMarkerNorthMargin) of the medium in units identified
         by prtMarkerAddressabilityUnit. Printing within the area
         bounded by all four margins is guaranteed for all
         interpreters. The value (-2) means unknown."
    ::= { prtMarkerEntry 13 }

prtMarkerEastMargin OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The margin from the East edge (see
         prtMarkerNorthMargin) of the medium in units identified
         by prtMarkerAddressabilityUnit. Printing within the area
         bounded by all four margins is guaranteed for all
         interpreters. The value (-2) means unknown."
    ::= { prtMarkerEntry 14 }

prtMarkerStatus OBJECT-TYPE
    SYNTAX     PrtSubUnitStatusTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The current status of this marker sub-unit."
    ::= { prtMarkerEntry 15 }

-- The Marker Supplies Group
--
-- This group is optional.  However, to claim conformance to this
-- group, it is necessary to implement every object in the group.

prtMarkerSupplies OBJECT IDENTIFIER ::= { printmib 11 }

prtMarkerSuppliesTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtMarkerSuppliesEntry


Turner                 Printer MIB V2                  [Page 101]


INTERNET DRAFT          Printer MIB              January 22, 1999



    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "A table of the marker supplies available on this
         printer."
    ::= { prtMarkerSupplies 1 }

prtMarkerSuppliesEntry OBJECT-TYPE
    SYNTAX     PrtMarkerSuppliesEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "Attributes of a marker supply. Entries may exist in the
         table for each device index with a device type of
         'printer'."
    INDEX  { hrDeviceIndex, prtMarkerSuppliesIndex }
    ::= { prtMarkerSuppliesTable 1 }

PrtMarkerSuppliesEntry ::= SEQUENCE {
    prtMarkerSuppliesIndex          Integer32,
    prtMarkerSuppliesMarkerIndex    Integer32,
    prtMarkerSuppliesColorantIndex  Integer32,
    prtMarkerSuppliesClass          PrtMarkerSuppliesClassTC,
    prtMarkerSuppliesType           PrtMarkerSuppliesTypeTC,
    prtMarkerSuppliesDescription    OCTET STRING,
    prtMarkerSuppliesSupplyUnit    PrtMarkerSuppliesSupplyUnitTC,
    prtMarkerSuppliesMaxCapacity    Integer32,
    prtMarkerSuppliesLevel          Integer32
}


prtMarkerSuppliesIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "A unique value used by the printer to identify this
         marker supply.  Although these values may change due to
         a major reconfiguration of the device (e.g. the addition
         of new marker supplies to the printer), values are
         expected to remain stable across successive power
         cycles."
::= { prtMarkerSuppliesEntry 1 }

prtMarkerSuppliesMarkerIndex OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-only
    STATUS     current


Turner                 Printer MIB V2                  [Page 102]


INTERNET DRAFT          Printer MIB              January 22, 1999



    DESCRIPTION
         "The value of prtMarkerIndex corresponding to the
         marking sub-unit with which this marker supply sub-unit
         is associated."
    ::= { prtMarkerSuppliesEntry 2 }

prtMarkerSuppliesColorantIndex OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The value of prtMarkerColorantIndex corresponding to
         the colorant with which this marker supply sub-unit is
         associated.  This value shall be 0 if there is no
         colorant table or if this supply does not depend on a
         single specified colorant."
    ::= { prtMarkerSuppliesEntry 3 }

prtMarkerSuppliesClass OBJECT-TYPE
    --  This value is a type 1 enumeration
    SYNTAX     PrtMarkerSuppliesClassTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "Indicates whether this supply entity represents a
         supply that is consumed or a receptacle that is filled."
    ::= { prtMarkerSuppliesEntry 4 }

prtMarkerSuppliesType OBJECT-TYPE
    --   This value is a type 3 enumeration
    SYNTAX     PrtMarkerSuppliesTypeTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The type of this supply."
    ::= { prtMarkerSuppliesEntry 5 }

prtMarkerSuppliesDescription OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..255))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The description of this supply container/receptacle in
         the localization specified by
         prtGeneralCurrentLocalization."
    ::= { prtMarkerSuppliesEntry 6 }

prtMarkerSuppliesSupplyUnit OBJECT-TYPE


Turner                 Printer MIB V2                  [Page 103]


INTERNET DRAFT          Printer MIB              January 22, 1999



    -- This value is a type 1 enumeration
    SYNTAX     PrtMarkerSuppliesSupplyUnitTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "Unit of measure of this marker supply
         container/receptacle."
    ::= { prtMarkerSuppliesEntry 7 }

prtMarkerSuppliesMaxCapacity OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The maximum capacity of this supply
         container/receptacle expressed in
         prtMarkerSuppliesSupplyUnit. If this supply
         container/receptacle can reliably sense this value, the
         value is reported by the printer and is read-only;
         otherwise, the value may be written (by a Remote Control
         Panel or a Management Application). The value (-1) means
         other and specifically indicates that the sub-unit
         places no restrictions on this parameter. The value (-2)
         means unknown."
    ::= { prtMarkerSuppliesEntry 8 }

prtMarkerSuppliesLevel OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The current level if this supply is a container;
         remaining space if this supply is a receptacle. If this
         supply container/receptacle can reliably sense this
         value, the value is reported by the printer and is read-
         only; otherwise, the value may be written (by a Remote
         Control Panel or a Management Application). The value (-
         1) means other and specifically indicates that the sub-
         unit places no restrictions on this parameter. The value
         (-2) means unknown.  A value of (-3) means that the
         printer knows that there is some supply/remaining space,
         respectively."
    ::= { prtMarkerSuppliesEntry 9 }

-- The Marker Colorant Group
--
-- This group is optional.  However, to claim conformance to this
-- group, it is necessary to implement every object in the group.


Turner                 Printer MIB V2                  [Page 104]


INTERNET DRAFT          Printer MIB              January 22, 1999




prtMarkerColorant OBJECT IDENTIFIER ::= { printmib 12 }

prtMarkerColorantTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtMarkerColorantEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "A table of all of the colorants available on the
         printer."
    ::= { prtMarkerColorant 1 }

prtMarkerColorantEntry OBJECT-TYPE
    SYNTAX     PrtMarkerColorantEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "Attributes of a colorant available on the printer.
         Entries may exist in the table for each device index
         with a device type of 'printer'."
    INDEX { hrDeviceIndex, prtMarkerColorantIndex }
    ::= { prtMarkerColorantTable 1 }

PrtMarkerColorantEntry ::= SEQUENCE {
        prtMarkerColorantIndex          Integer32,
        prtMarkerColorantMarkerIndex    Integer32,
        prtMarkerColorantRole           PrtMarkerColorantRoleTC,
        prtMarkerColorantValue          OCTET STRING,
        prtMarkerColorantTonality       Integer32
}

prtMarkerColorantIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "A unique value used by the printer to identify this
        colorant. Although these values may change due to a major
        reconfiguration of the device (e.g. the addition of new
        colorants to the printer)."
    ::= { prtMarkerColorantEntry 1 }

prtMarkerColorantMarkerIndex OBJECT-TYPE
    SYNTAX     Integer32 (0..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION



Turner                 Printer MIB V2                  [Page 105]


INTERNET DRAFT          Printer MIB              January 22, 1999



         "The value of prtMarkerIndex corresponding to the marker
         sub-unit with which this colorant entry is associated."
    ::= { prtMarkerColorantEntry 2 }

prtMarkerColorantRole OBJECT-TYPE
    -- This value is a type 1 enumeration
    SYNTAX     PrtMarkerColorantRoleTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The role played by this colorant."
    ::= { prtMarkerColorantEntry 3 }

prtMarkerColorantValue OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..255))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The name of the color of this colorant using
         standardized string names from ISO 10175 (DPA) and ISO
         10180 (SPDL) which are:
           other
           unknown
           white
           red
           green
           blue
           cyan
           magenta
           yellow
           black
         Implementers may add additional string values. The
         naming conventions in ISO 9070 are recommended in order
         to avoid potential name clashes"
    ::= { prtMarkerColorantEntry 4 }

prtMarkerColorantTonality OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The distinct levels of tonality realizable by a marking
         sub-unit when using this colorant.  This value does not
         include the number of levels of tonal difference that an
         interpreter can obtain by techniques such as half
         toning. This value must be at least 2."
    ::= { prtMarkerColorantEntry 5 }



Turner                 Printer MIB V2                  [Page 106]


INTERNET DRAFT          Printer MIB              January 22, 1999



-- The Media Path Group
--
-- The media paths encompass the mechanisms in the printer that
-- move the media through the printer and connect all other media
-- related sub-units: inputs, outputs, markers and finishers. A
-- printer contains one or more media paths. These are
-- represented by the Media Path Group in the model. The Media
-- Path group has some attributes that apply to all
-- paths plus a table of the separate media paths.

prtMediaPath OBJECT IDENTIFIER ::= { printmib 13 }


prtMediaPathTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtMediaPathEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        ""
    ::= { prtMediaPath 4 }

prtMediaPathEntry OBJECT-TYPE
    SYNTAX     PrtMediaPathEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "Entries may exist in the table for each device index
         with a device type of 'printer'."
    INDEX  { hrDeviceIndex, prtMediaPathIndex }
    ::= { prtMediaPathTable 1 }

PrtMediaPathEntry ::= SEQUENCE {
    prtMediaPathIndex               Integer32,
    prtMediaPathMaxSpeedPrintUnit
                          PrtMediaPathMaxSpeedPrintUnitTC,
    prtMediaPathMediaSizeUnit       PrtMediaUnitTC,
    prtMediaPathMaxSpeed            Integer32,
    prtMediaPathMaxMediaFeedDir     Integer32,
    prtMediaPathMaxMediaXFeedDir    Integer32,
    prtMediaPathMinMediaFeedDir     Integer32,
    prtMediaPathMinMediaXFeedDir    Integer32,
    prtMediaPathType                PrtMediaPathTypeTC,
    prtMediaPathDescription         OCTET STRING,
    prtMediaPathStatus              PrtSubUnitStatusTC
}


prtMediaPathIndex OBJECT-TYPE


Turner                 Printer MIB V2                  [Page 107]


INTERNET DRAFT          Printer MIB              January 22, 1999



    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "A unique value used by the printer to identify this
         media path. Although these values may change due to a
         major reconfiguration of the device (e.g. the addition
         of new media paths to the printer), values are expected
         to remain stable across successive printer power
         cycles."
    ::= { prtMediaPathEntry 1 }

prtMediaPathMaxSpeedPrintUnit OBJECT-TYPE
    -- This value is a type 1 enumeration
    SYNTAX PrtMediaPathMaxSpeedPrintUnitTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The unit of measure used in specifying the speed of all
         media paths in the printer."
    ::= { prtMediaPathEntry 2 }

prtMediaPathMediaSizeUnit OBJECT-TYPE
    SYNTAX     PrtMediaUnitTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The units of measure of media size for use in
         calculating and relaying dimensional values for all
         media paths in the printer."
    ::= { prtMediaPathEntry 3 }

prtMediaPathMaxSpeed OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The maximum printing speed of this media path expressed
         in prtMediaPathMaxSpeedUnit's.  A value of (-1) implies
         'other'."
    ::= { prtMediaPathEntry 4 }

prtMediaPathMaxMediaFeedDir OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION



Turner                 Printer MIB V2                  [Page 108]


INTERNET DRAFT          Printer MIB              January 22, 1999



         "The maximum physical media size in the feed direction
         of this media path expressed in units of measure
         specified by PrtMediaPathMediaSizeUnit.  A value of (-1)
         implies 'unlimited' a value of (-2) implies 'unknown'"
    ::= { prtMediaPathEntry 5 }

prtMediaPathMaxMediaXFeedDir OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The maximum physical media size across the feed
         direction of this media path expressed in units of
         measure specified by prtMediaPathMediaSizeUnit.  A value
         of (-2) implies 'unknown'."
    ::= { prtMediaPathEntry 6 }

prtMediaPathMinMediaFeedDir OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The minimum physical media size in the feed direction
         of this media path expressed in units of measure
         specified by prtMediaPathMediaSizeUnit. A value of (-2)
         implies 'unknown'."
    ::= { prtMediaPathEntry 7 }

prtMediaPathMinMediaXFeedDir OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The minimum physical media size across the feed
         direction of this media path expressed in units of
         measure specified by prtMediaPathMediaSizeUnit.  A value
         of (-2) implies 'unknown'."
    ::= { prtMediaPathEntry 8 }

prtMediaPathType OBJECT-TYPE
    --   This value is a type 2 enumeration
    SYNTAX     PrtMediaPathTypeTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The type of the media path for this media path."
    ::= { prtMediaPathEntry 9 }



Turner                 Printer MIB V2                  [Page 109]


INTERNET DRAFT          Printer MIB              January 22, 1999



prtMediaPathDescription OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..255))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The manufacturer-provided description of this media
         path in the localization specified by
         prtGeneralCurrentLocalization."
    ::= { prtMediaPathEntry 10 }

prtMediaPathStatus OBJECT-TYPE
    SYNTAX     PrtSubUnitStatusTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The current status of this media path."
    ::= { prtMediaPathEntry 11 }

-- The Print Job Delivery Channel Group
--
-- Implementation of every object in this group is mandatory.
--
-- Print Job Delivery Channels are independent sources of print
-- data. Here, print data is the term used for the information
-- that is used to construct printed pages and may have both data
-- and control aspects. The output of a channel is in a form
-- suitable for input to one of the interpreters as a
-- stream. A channel may be independently enabled (allowing
-- print data to flow) or disabled (stopping the flow of
-- print data). A printer may have one or more channels.
--
-- The Print Job Delivery Channel table describes the
-- capabilities of the printer and not what is currently being
-- performed by the printer
--
-- Basically, the print job delivery channel abstraction
-- describes the final processing step of getting the print data
-- to an interpreter. It might include some level of
-- decompression or decoding of print stream data.
-- channel. All of these aspects are hidden in the channel
-- abstraction.
--
-- There are many kinds of print job delivery channels; some of
-- which are based on networks and others which are not. For
-- example, a channel can be a serial (or parallel) connection;
-- it can be a service, such as the UNIX Line Printer Daemon
-- (LPD), offering services over a network connection; or
-- it could be a disk drive into which a floppy disk with


Turner                 Printer MIB V2                  [Page 110]


INTERNET DRAFT          Printer MIB              January 22, 1999



-- the print data is inserted. Each print job delivery channel is
-- identified by the electronic path and/or service protocol
-- used to deliver print data to a print data interpreter.
--
-- Channel example                   Implementation
--
-- serial port channel            bi-directional data channel
-- parallel port channel          often uni-directional channel
-- IEEE 1284 port channel         bi-directional channel
-- SCSI port channel              bi-directional
-- Apple PAP channel              may be based on LocalTalk,
--                                Ethernet or Tokentalk
-- LPD Server channel             TCP/IP based, port 515
-- Netware Remote Printer         SPX/IPX based channel
-- Netware Print Server           SPX/IPX based channel
--
-- It is easy to note that this is a mixed bag.  There are
-- some physical connections over which no (or very meager)
-- protocols are run (e.g. the serial or old parallel ports)
-- and there are services which often have elaborate
-- protocols that run over a number of protocol stacks. In
-- the end, what is important is the delivery of print data
-- through the channel.
--
-- The print job delivery channel sub-units are represented by
-- the Print Job Delivery Channel Group in the Model. It has a
-- current print job control language, which can be used to
-- specify which interpreter is to be used for the print data and
-- to query and change environment variables used by the
-- interpreters (and Management Applications). There is also a
-- default interpreter that is to be used if an interpreter is
-- not explicitly specified using the Control Language.

-- The first seven items in the Print Job Delivery Channel Table
-- define the "channel" itself.  A channel typically depends on
-- other protocols and interfaces to provide the data that flows
-- through the channel.
--
-- Control of a print job delivery channel is largely limited to
-- enabling or disabling the entire channel itself. It is likely
-- that more control of the process of accessing print data
-- will be needed over time. Thus, the ChannelType will
-- allow type-specific data to be associated with each
-- channel (using ChannelType specific groups in a fashion
-- analogous to the media specific MIBs that are associated
-- with the IANAIfType in the Interfaces Table). As a first
-- step in this direction, each channel will identify the
-- underlying Interface on which it is based. This is the


Turner                 Printer MIB V2                  [Page 111]


INTERNET DRAFT          Printer MIB              January 22, 1999



-- eighth object in each row of the table.


-- The Print Job Delivery Channel Table
--
-- The prtChannelTable represents the set of input data sources
-- which can provide print data to one or more of the
-- interpreters available on a printer


prtChannel OBJECT IDENTIFIER ::= { printmib 14 }

prtChannelTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtChannelEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        ""
    ::= { prtChannel 1 }

prtChannelEntry OBJECT-TYPE
    SYNTAX     PrtChannelEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "Entries may exist in the table for each device index
         with a device type of 'printer'."
    INDEX  { hrDeviceIndex, prtChannelIndex }
    ::= { prtChannelTable 1 }

PrtChannelEntry ::= SEQUENCE {
    prtChannelIndex                     Integer32,
    prtChannelType                      PrtChannelTypeTC,
    prtChannelProtocolVersion           OCTET STRING,
    prtChannelCurrentJobCntlLangIndex   Integer32,
    prtChannelDefaultPageDescLangIndex  Integer32,
    prtChannelState                     PrtChannelStateTC,
    prtChannelIfIndex                   Integer32,
    prtChannelStatus                    PrtSubUnitStatusTC,
    prtChannelInformation               OCTET STRING
}

prtChannelIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION



Turner                 Printer MIB V2                  [Page 112]


INTERNET DRAFT          Printer MIB              January 22, 1999



         "A unique value used by the printer to identify this
         data channel.  Although these values may change due to a
         major reconfiguration of the device (e.g. the addition
         of new data channels to the printer), values are
         expected to remain stable across successive printer
         power cycles."
    ::= { prtChannelEntry 1 }

prtChannelType OBJECT-TYPE
    SYNTAX     PrtChannelTypeTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The type of this print data channel.  This object
         provides the linkage to ChannelType-specific groups that
         may (conceptually) extend the prtChannelTable with
         additional details about that channel."
    ::= { prtChannelEntry 2 }

prtChannelProtocolVersion OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..63))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The version of the protocol used on this channel.  The
         format used for version numbering depends on
         prtChannelType."
    ::= { prtChannelEntry 3 }

prtChannelCurrentJobCntlLangIndex OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The value of prtInterpreterIndex corresponding to the
         Control Language Interpreter for this channel. This
         interpreter defines the syntax used for control
         functions, such as querying or changing environment
         variables and identifying job boundaries (e.g. PJL,
         PostScript, NPAP). A value of zero indicates that there
         is no current Job Control Language Interpreter for this
         channel"
    ::= { prtChannelEntry 4 }

prtChannelDefaultPageDescLangIndex OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current


Turner                 Printer MIB V2                  [Page 113]


INTERNET DRAFT          Printer MIB              January 22, 1999



    DESCRIPTION
         "The value of prtInterpreterIndex corresponding to the
         Page Description Language Interpreter for this channel.
         This interpreter defines the default Page Description
         Language interpreter to be used for the print data
         unless the Control Language is used to select a specific
         interpreter (e.g., PCL, PostScript Language, auto-
         sense). A value of zero indicates that there is no
         default page description language interpreter for this
         channel."
    ::= { prtChannelEntry 5 }

prtChannelState OBJECT-TYPE
    -- This value is a type 1 enumeration
    SYNTAX     PrtChannelStateTC
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The state of this print data channel. The value
         determines whether control information and print data is
         allowed through this channel or not."
    ::= { prtChannelEntry 6 }

prtChannelIfIndex OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The value of ifIndex (in the ifTable; see the interface
         section of MIB-2/RFC 1213) which corresponds to this
         channel. When more than one row of the ifTable is
         relevant, this is the index of the row representing the
         topmost layer in the interface hierarchy.  A value of
         zero indicates that no interface is associated with this
         channel."
    ::= { prtChannelEntry 7 }

prtChannelStatus OBJECT-TYPE
    SYNTAX     PrtSubUnitStatusTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The current status of the channel."
    ::= { prtChannelEntry 8 }


prtChannelInformation OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE (0..255))


Turner                 Printer MIB V2                  [Page 114]


INTERNET DRAFT          Printer MIB              January 22, 1999



    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "Auxiliary information to allow a printing application
         to use the channel for data submission to the printer.
         An application capable of using a specific
         PrtChannelType should be able to use the combined
         information from the prtChannelInformation and other
         channel and interface group objects to 'bootstrap' its
         use of the channel.  prtChannelInformation is not
         intended to provide a general channel description, nor
         to provide information that is available once the
         channel is in use.

         The encoding and interpretation of the
         prtChannelInformation object is specific to channel
         type.  The description of each PrtChannelType enum value
         for which prtChannelInformation is defined specifies the
         appropriate encoding and interpretation, including
         interaction with other objects.  For channel types that
         do not specify a prtChannelInformation value, its value
         shall be null (0 length).

         When a new PrtChannelType enumeration value is
         registered, its accompanying description must specify
         the encoding and interpretation of the
         prtChannelInformation value for the channel type.
         prtChannelInformation semantics for an existing
         PrtChannelType may be added or amended in the same
         manner as described in section 2.4.1 for type 2
         enumeration values.

         The prtChannelInformation specifies values for a
         collection of channel attributes, represented as text
         according to the following rules:

         1. The prtChannelInformation is not affected by
         localization.

         2. The prtChannelInformation is a list of entries
         representing the attribute values.  Each entry consists
         of the following items, in order:

         a. a keyword, composed of alphabetic characters (A-Z,
         a-z) represented by their NVT ASCII [NVT ASCII] codes,
         that identifies a channel attribute,




Turner                 Printer MIB V2                  [Page 115]


INTERNET DRAFT          Printer MIB              January 22, 1999



         b. the NVT ASCII code for an Equals Sign (=) (code 61)
         to delimit the keyword,

         c. a data value encoded using rules specific to the
         PrtChannelType to with the prtChannelInformation applies
         which must in no case allow an octet with value 10 (the
         NVT ASCII Line Feed code),

         d. the NVT ASCII code for a Line Feed character (code
         10) to delimit the data value.

         No other octets shall be present.

         Keywords are case-sensitive.  Conventionally, keywords
         are capitalized (including each word of a multi-word
         keyword) and since they occupy space in the
         prtChannelInformation, they are kept short.

         3. If a channel attribute has multiple values, it is
         represented by multiple entries with the same keyword,
         each specifying one value. Otherwise, there shall be at
         most one entry for each attribute.

         4. By default, entries may appear in any order.  If
         there are ordering constraints for particular entries,
         these must be specified in their definitions.

         5. The prtChannelInformation value by default consists
         of text represented by NVT ASCII graphics character
         codes. However, other representations may be specified:

         a. In cases where the prtChannelInformation value
         contains information not normally coded in textual form,
         whatever symbolic representation is conventionally used
         for the information should be used for encoding the
         prtChannelInformation value. (For instance, a binary
         port value might be represented as a decimal number
         using NVT ASCII codes.) Such encoding must be specified
         in the definition of the value.

         b. The value may contain textual information in a
         character set other than NVT ASCII graphics characters.
         (For instance, an identifier might consist of ISO 10646
         text encoded using the UTF-8 encoding scheme.) Such a
         character set and its encoding must be specified in the
         definition of the value.

         6. For each PrtChannelType for which


Turner                 Printer MIB V2                  [Page 116]


INTERNET DRAFT          Printer MIB              January 22, 1999



         prtChannelInformation entries are defined, the
         descriptive text associated with the PrtChannelType
         enumeration value shall specify the following
         information for each entry:

         Title:        Brief description phrase, e.g.: 'Port
                       name', 'Service Name', etc.

         Keyword:      The keyword value, e.g.: 'Port' or
                       'Service'

         Syntax:       The encoding of the entry value if it
                       cannot be directly represented by NVT
                       ASCII.

         Status:       'Mandatory', 'Optional', or 'Conditionally
                       Mandatory'

         Multiplicity: 'Single' or 'Multiple' to indicate whether
                       the entry may be present multiple times.

         Description:  Description of the use of the entry, other
                       information required to complete the
                       definition (e.g.: ordering constraints,
                       interactions between entries).

         Applications that interpret prtChannelInformation should
         ignore unrecognized entries, so they are not affected if
         new entry types are added."

     ::= { prtChannelEntry 9 }

--
-- The Interpreter Group
--
-- The interpreter sub-units are responsible for the conversion
-- of a description of intended print instances into images that
-- are to be marked on the media. A printer may have one or more
-- interpreters. The interpreter sub-units are represented by the
-- Interpreter Group in the Model. Each interpreter is generally
-- implemented with software running on the System Controller
-- sub-unit. The Interpreter Table has one entry per interpreter
-- where the interpreters include both Page Description Language
-- (PDL) Interpreters and Control Language Interpreters.
--
-- Implementation of every object in this group is mandatory.




Turner                 Printer MIB V2                  [Page 117]


INTERNET DRAFT          Printer MIB              January 22, 1999



prtInterpreter OBJECT IDENTIFIER ::= { printmib 15 }

--       Interpreter Table
--
-- The prtInterpreterTable is a table representing the
-- interpreters in the printer.  An entry shall be placed in the
-- interpreter table for each interpreter on the printer.

prtInterpreterTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtInterpreterEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        ""
    ::= { prtInterpreter 1 }

prtInterpreterEntry OBJECT-TYPE
    SYNTAX     PrtInterpreterEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "Entries may exist in the table for each device index
         with a device type of 'printer'."
    INDEX  { hrDeviceIndex, prtInterpreterIndex }
    ::= { prtInterpreterTable 1 }

PrtInterpreterEntry ::= SEQUENCE {
    prtInterpreterIndex                 Integer32,
    prtInterpreterLangFamily         PrtInterpreterLangFamilyTC,
    prtInterpreterLangLevel             OCTET STRING,
    prtInterpreterLangVersion           OCTET STRING,
    prtInterpreterDescription           OCTET STRING,
    prtInterpreterVersion               OCTET STRING,
    prtInterpreterDefaultOrientation    PrtPrintOrientationTC,
    prtInterpreterFeedAddressability    Integer32,
    prtInterpreterXFeedAddressability   Integer32,
    prtInterpreterDefaultCharSetIn      CodedCharSet,
    prtInterpreterDefaultCharSetOut     CodedCharSet,
    prtInterpreterTwoWay                PrtInterpreterTwoWayTC
}

prtInterpreterIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "A unique value for each PDL or control language for
         which there exists an interpreter or emulator in the


Turner                 Printer MIB V2                  [Page 118]


INTERNET DRAFT          Printer MIB              January 22, 1999



         printer. The value is used to identify this interpreter.
         Although these values may change due to a major
         reconfiguration of the device (e.g. the addition of new
         interpreters to the printer), values are expected to
         remain stable across successive printer power cycles."
    ::= { prtInterpreterEntry 1 }

prtInterpreterLangFamily OBJECT-TYPE
    -- This value is a type 2 enumeration
    SYNTAX     PrtInterpreterLangFamilyTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The family name of a Page Description Language (PDL) or
         control language which this interpreter in the printer
         can interpret or emulate."
    ::= { prtInterpreterEntry 2 }

prtInterpreterLangLevel OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..31))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The level of the language which this interpreter is
         interpreting or emulating.  This might contain a value
         like '5e' for an interpreter which is emulating level 5e
         of the PCL language. It might contain '2' for an
         interpreter which is emulating level 2 of the PostScript
         language. Similarly it might contain '2' for an
         interpreter which is emulating level 2 of the HPGL
         language."
    ::= { prtInterpreterEntry 3 }

prtInterpreterLangVersion OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..31))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The date code or version of the language which this
         interpreter is interpreting or emulating."
    ::= { prtInterpreterEntry 4 }

prtInterpreterDescription OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..255))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION



Turner                 Printer MIB V2                  [Page 119]


INTERNET DRAFT          Printer MIB              January 22, 1999



         "A string to identify this interpreter in the
         localization specified by prtGeneralCurrentLocalization
         as opposed to the language which is being interpreted.
         It is anticipated that this string will allow
         manufacturers to unambiguously identify their
         interpreters."
    ::= { prtInterpreterEntry 5 }

prtInterpreterVersion OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..31))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The date code, version number, or other product
         specific information tied to this interpreter.  This
         value is associated with the interpreter, rather than
         with the version of the language which is being
         interpreted or emulated."
    ::= { prtInterpreterEntry 6 }

prtInterpreterDefaultOrientation OBJECT-TYPE
    -- This value is a type 1 enumeration
    SYNTAX     PrtPrintOrientationTC
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The current orientation default for this interpreter.
         This value may be overridden for a particular job (e.g.,
         by a command in the input data stream)."
    ::= { prtInterpreterEntry 7 }

prtInterpreterFeedAddressability OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The maximum interpreter addressability in the feed
         direction in 10000 prtMarkerAddressabilityUnits (see
         prtMarkerAddressabilityFeedDir ) for this interpreter.
         The value (-1) means other and specifically indicates
         that the sub-unit places no restrictions on this
         parameter."
    ::= { prtInterpreterEntry 8 }

prtInterpreterXFeedAddressability OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current


Turner                 Printer MIB V2                  [Page 120]


INTERNET DRAFT          Printer MIB              January 22, 1999



    DESCRIPTION
         "The maximum interpreter addressability in the cross
         feed direction in 10000 prtMarkerAddressabilityUnits
         (see prtMarkerAddressabilityXFeedDir) for this
         interpreter. The value (-1) means other and specifically
         indicates that the sub-unit places no restrictions on
         this parameter."
    ::= { prtInterpreterEntry 9 }

prtInterpreterDefaultCharSetIn OBJECT-TYPE
    SYNTAX     CodedCharSet
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The default coded character set for input octets
         encountered outside a context in which the Page
         Description Language established the interpretation of
         the octets. (Input octets are presented to the
         interpreter through a path defined in the channel
         group.) This value shall be (2) if there is no default."
     ::= { prtInterpreterEntry 10 }

prtInterpreterDefaultCharSetOut OBJECT-TYPE
    SYNTAX     CodedCharSet
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The default character set for data coming from this
         interpreter through the printer's output channel (i.e.
         the 'backchannel'). This value shall be (2) if there is
         no default."
    ::= { prtInterpreterEntry 11 }

prtInterpreterTwoWay OBJECT-TYPE
    -- This value is a type 1 enumeration
    SYNTAX     PrtInterpreterTwoWayTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "Indicates whether or not this interpreter returns
         information back to the host."
    ::= { prtInterpreterEntry 12 }

-- The Console Group
--
-- Many printers have a console on the printer, the operator
-- console, that is used to display and modify the state of the
-- printer. The console can be as simple as a few indicators and


Turner                 Printer MIB V2                  [Page 121]


INTERNET DRAFT          Printer MIB              January 22, 1999



-- switches or as complicated as full screen displays and
-- keyboards. There can be at most one such console.

-- Implementation of every object in this group is mandatory.

-- The Display Buffer Table

prtConsoleDisplayBuffer OBJECT IDENTIFIER ::= { printmib 16 }

prtConsoleDisplayBufferTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtConsoleDisplayBufferEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "Physical display buffer for printer console display or
         operator panel"
    ::= { prtConsoleDisplayBuffer 5 }

prtConsoleDisplayBufferEntry OBJECT-TYPE
    SYNTAX     PrtConsoleDisplayBufferEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "This table contains one entry for each physical line on
         the display.  Lines cannot be added or deleted. Entries
         may exist in the table for each device index with a
         device type of 'printer'."
    INDEX  { hrDeviceIndex, prtConsoleDisplayBufferIndex }
    ::= { prtConsoleDisplayBufferTable 1 }

PrtConsoleDisplayBufferEntry ::= SEQUENCE {
    prtConsoleDisplayBufferIndex    Integer32,
    prtConsoleDisplayBufferText     OCTET STRING
}

prtConsoleDisplayBufferIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "A unique value for each console line in the printer.
         The value is used to identify this console line.
         Although these values may change due to a major
         reconfiguration of the device (e.g. the addition of new
         console lines to the printer). Values are normally
         expected to remain stable across successive printer
         power cycles."
    ::= { prtConsoleDisplayBufferEntry 1 }


Turner                 Printer MIB V2                  [Page 122]


INTERNET DRAFT          Printer MIB              January 22, 1999




prtConsoleDisplayBufferText OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..255))
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "The content of a line in the logical display buffer of
         the operator's console of the printer.  When a write
         operation occurs, normally a critical message, to one of
         the LineText strings, the agent should make that line
         displayable if a physical display is present.  Writing a
         zero length string clears the line.  It is an
         implementation-specific matter as to whether the agent
         allows a line to be overwritten before it has been
         cleared. Printer generated strings shall be in the
         localization specified by prtConsoleLocalization.
         Management Application generated strings should be
         localized by the Management Application."
    ::= { prtConsoleDisplayBufferEntry 2 }

-- The Console Light Table

prtConsoleLights OBJECT IDENTIFIER ::= { printmib 17 }

prtConsoleLightTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtConsoleLightEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        ""
    ::= { prtConsoleLights 6 }

prtConsoleLightEntry OBJECT-TYPE
    SYNTAX     PrtConsoleLightEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "Entries may exist in the table for each device index
         with a device type of 'printer'."
    INDEX  { hrDeviceIndex, prtConsoleLightIndex }
    ::= { prtConsoleLightTable 1 }

PrtConsoleLightEntry ::= SEQUENCE {
    prtConsoleLightIndex            Integer32,
    prtConsoleOnTime                Integer32,
    prtConsoleOffTime               Integer32,
    prtConsoleColor                 PrtConsoleColorTC,
    prtConsoleDescription           OCTET STRING


Turner                 Printer MIB V2                  [Page 123]


INTERNET DRAFT          Printer MIB              January 22, 1999



}

prtConsoleLightIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
         "A unique value used by the printer to identify this
         light. Although these values may change due to a major
         reconfiguration of the device (e.g. the addition of new
         lights to the printer). Values are normally expected to
         remain stable across successive printer power cycles."
    ::= { prtConsoleLightEntry 1 }

prtConsoleOnTime OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "This object, in conjunction with prtConsoleOffTime,
         defines the current status of the light.  If both
         prtConsoleOnTime and prtConsoleOffTime are non-zero, the
         lamp is blinking and the values presented define the on
         time and off time, respectively, in milliseconds. If
         prtConsoleOnTime is zero and prtConsoleOffTime is non-
         zero, the lamp is off. If prtConsoleOffTime is zero and
         prtConsoleOnTime is non-zero, the lamp is on. If both
         values are zero the lamp is off."
    ::= { prtConsoleLightEntry 2 }

prtConsoleOffTime OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-write
    STATUS     current
    DESCRIPTION
         "This object, in conjunction with prtConsoleOnTime,
         defines the current status of the light. If both
         prtConsoleOnTime and prtConsoleOffTime are non-zero, the
         lamp is blinking and the values presented define the on
         time and off time, respectively, in milliseconds. If
         prtConsoleOnTime is zero and prtConsoleOffTime is non-
         zero, the lamp is off. If prtConsoleOffTime is zero and
         prtConsoleOnTime is non-zero, the lamp is on. If both
         values are zero the lamp is off."
    ::= { prtConsoleLightEntry 3 }

prtConsoleColor OBJECT-TYPE
    -- This value is a type 2 enumeration


Turner                 Printer MIB V2                  [Page 124]


INTERNET DRAFT          Printer MIB              January 22, 1999



    SYNTAX     PrtConsoleColorTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "The color of this light."
    ::= { prtConsoleLightEntry 4 }

prtConsoleDescription OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..255))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The vendor description or label of this light in the
         localization specified by prtConsoleLocalization."
    ::= { prtConsoleLightEntry 5 }


-- The Alerts Group
--
-- The prtAlertTable lists all the critical and non-critical
-- alerts currently active in the printer.  A critical alert is
-- one that stops the printer from printing immediately and
-- printing can not continue until the critical alert condition
-- is eliminated.  Non-critical alerts are those items that do
-- not stop printing but may at some future time.
-- The table contains information on the severity, component,
-- detail location within the component, alert code and
-- description of each critical alert that is currently active
-- within the printer.  See 2.2.13 for a more complete
-- description of the alerts table and its management.
--
-- Each parameter in the Trap PDU is a full OID which itself is
-- indexed by the host resources MIB "hrDeviceIndex" object. In
-- order for a management station to obtain the correct
-- "hrDeviceIndex" associated with a particular Trap PDU, the
-- "hrDeviceIndex" value can be extracted from the returned OID
-- value in the Trap PDU when the PDU is received by the
-- Management station.
--
-- Implementation of every object in this group is mandatory.

prtAlert OBJECT IDENTIFIER ::= { printmib 18 }

prtAlertTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF PrtAlertEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION


Turner                 Printer MIB V2                  [Page 125]


INTERNET DRAFT          Printer MIB              January 22, 1999



        ""
    ::= { prtAlert 1 }

prtAlertEntry OBJECT-TYPE
    SYNTAX     PrtAlertEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
        "Entries may exist in the table for each device
        index with a device type of 'printer'."
    INDEX  { hrDeviceIndex, prtAlertIndex }
    ::= { prtAlertTable 1 }

PrtAlertEntry ::= SEQUENCE {
    prtAlertIndex               Integer32,
    prtAlertSeverityLevel       PrtAlertSeverityLevelTC,
    prtAlertTrainingLevel       PrtAlertTrainingLevelTC,
    prtAlertGroup               PrtAlertGroupTC,
    prtAlertGroupIndex          Integer32,
    prtAlertLocation            Integer32,
    prtAlertCode                PrtAlertCodeTC,
    prtAlertDescription         OCTET STRING,
    prtAlertTime                TimeTicks
}

prtAlertIndex OBJECT-TYPE
    SYNTAX     Integer32 (1..65535)
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The index value used to determine which alerts have
         been added or removed from the alert table. This is an
         incrementing integer starting from zero every time the
         printer is reset.  When the printer adds an alert to the
         table, that alert is assigned the next higher integer
         value from the last item entered into the table.  If the
         index value reaches its maximum value, the next item
         entered will cause the index value to roll over and
         start at zero again.  The first event placed in the
         alert table after a reset of the printer shall have an
         index value of 1.  NOTE: The management application will
         read the alert table when a trap or event notification
         occurs or at a periodic rate and then parse the table to
         determine if any new entries were added by comparing the
         last known index value with the current highest index
         value. The management application will then update its
         copy of the alert table.  When the printer discovers
         that an alert is no longer active, the printer shall


Turner                 Printer MIB V2                  [Page 126]


INTERNET DRAFT          Printer MIB              January 22, 1999



         remove the row for that alert from the table and shall
         reduce the number of rows in the table.  The printer may
         add or delete any number of rows from the table at any
         time.  The management station can detect when binary
         change alerts have been deleted by requesting an
         attribute of each alert, and noting alerts as deleted
         when that retrieval is not possible."
    ::= { prtAlertEntry 1 }

prtAlertSeverityLevel OBJECT-TYPE
    -- This value is a type 1 enumeration
    SYNTAX     PrtAlertSeverityLevelTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The level of severity of this alert table entry.  The
         printer determines the severity level assigned to each
         entry into the table."
    ::= { prtAlertEntry 2 }

prtAlertTrainingLevel OBJECT-TYPE
    -- This value is a type 2 enumeration
    SYNTAX     PrtAlertTrainingLevelTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "See textual convention PrtAlertTrainingLevelTC"
    ::= { prtAlertEntry 3 }

prtAlertGroup OBJECT-TYPE
    -- This value is a type 1 enumeration
    SYNTAX     PrtAlertGroupTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The type of sub-unit within the printer model that this
         alert is related. Input, output, and markers are
         examples of printer model groups, i.e., examples of
         types of sub-units. Wherever possible, these
         enumerations match the sub-identifier that identifies
         the relevant table in the printmib."
    ::= { prtAlertEntry 4 }

prtAlertGroupIndex OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION


Turner                 Printer MIB V2                  [Page 127]


INTERNET DRAFT          Printer MIB              January 22, 1999



         "An index of the row within the principle table in the
         group identified by prtAlertGroup that represents the
         sub-unit of the printer that caused this alert.  The
         combination of the prtAlertGroup and the
         prtAlertGroupIndex defines exactly which printer sub-
         unit caused the alert; for example, Input #3, Output #2,
         and Marker #1. Every object in this MIB is indexed with
         hrDeviceIndex and optionally, another index variable.
         If this other index variable is present in the table
         that generated the alert, it will be used as the value
         for this object.  Otherwise, this value shall be -1."
    ::= { prtAlertEntry 5 }

prtAlertLocation OBJECT-TYPE
    SYNTAX     Integer32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The sub-unit location that is defined by the printer
         manufacturer to further refine the location of this
         alert within the designated sub-unit.  The location is
         used in conjunction with the Group and GroupIndex
         values; for example, there is an alert in Input #2 at
         location number 7. The value (-2) indicates unknown"
    ::= { prtAlertEntry 6 }

prtAlertCode OBJECT-TYPE
    -- This value is a type 2 enumeration
    SYNTAX     PrtAlertCodeTC
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "See associated textual convention PrtAlertCodeTC"
    ::= { prtAlertEntry 7}

prtAlertDescription OBJECT-TYPE
    SYNTAX     OCTET STRING (SIZE(0..255))
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "A description of this alert entry in the localization
         specified by prtGeneralCurrentLocalization.  The
         description is provided by the printer to further
         elaborate on the enumerated alert or provide information
         in the case where the code is classified as 'other' or
         'unknown'.  The printer is required to return a
         description string but the string may be a null
         string."


Turner                 Printer MIB V2                  [Page 128]


INTERNET DRAFT          Printer MIB              January 22, 1999



    ::= { prtAlertEntry 8 }

prtAlertTime OBJECT-TYPE
    SYNTAX     TimeTicks
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
         "The value of sysUpTime at the time that this alert was
         generated."
    ::= { prtAlertEntry 9 }


printerV1Alert OBJECT-IDENTITY
    STATUS  current
    DESCRIPTION
         "The value of the enterprise-specific OID in an SNMPv1
         trap sent signaling a critical event in the
         prtAlertTable."
    ::= { prtAlert 2 }



printerV2AlertPrefix OBJECT IDENTIFIER ::= { printerV1Alert 0 }

printerV2Alert NOTIFICATION-TYPE
    OBJECTS { prtAlertIndex, prtAlertSeverityLevel,
prtAlertGroup, prtAlertGroupIndex, prtAlertLocation, prtAlertCode
}
    STATUS  current
    DESCRIPTION
         "This trap is sent whenever a critical event is added to
         the prtAlertTable."
    ::= { printerV2AlertPrefix 1 }



-- Note that the SNMPv2 to SNMPv1 translation rules dictate that
-- the preceding structure will result in SNMPv1 traps of the
-- following form:
--
-- printerAlert TRAP-TYPE
--     ENTERPRISE printerV1Alert
--     VARIABLES { prtAlertIndex, prtAlertSeverityLevel,
--                 prtAlertGroup, prtAlertGroupIndex,
--                 prtAlertLocation, prtAlertCode }
--     DESCRIPTION
--        "This trap is sent whenever a critical event is added
--         to the prtAlertTable."


Turner                 Printer MIB V2                  [Page 129]


INTERNET DRAFT          Printer MIB              January 22, 1999



--     ::= 1
--



-- Conformance Information

prtMIBConformance OBJECT IDENTIFIER ::= { printmib 2 }

-- compliance statements
prtMIBCompliance MODULE-COMPLIANCE
    STATUS  current
    DESCRIPTION
        "The compliance statement for agents that implement the
        printer MIB."
    MODULE -- this module
    MANDATORY-GROUPS { prtGeneralGroup, prtInputGroup,
                       prtOutputGroup,
                       prtMarkerGroup, prtMediaPathGroup,
                       prtChannelGroup, prtInterpreterGroup,
                       prtConsoleGroup, prtAlertTableGroup }

        OBJECT      prtGeneralReset
        SYNTAX      INTEGER {
                        notResetting(3),
                        resetToNVRAM(5)
                    }
        DESCRIPTION
         "It is conformant to implement just these two states in
         this object.  Any additional states are optional."

       OBJECT    prtGeneralCurrentLocalization
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtGeneralCurrentOperator
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtGeneralServicePerson
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtAuxiliarySheetStartupPage
       MIN-ACCESS  read-only


Turner                 Printer MIB V2                  [Page 130]


INTERNET DRAFT          Printer MIB              January 22, 1999



       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtAuxiliarySheetBannerPage
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtGeneralPrinterName
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtGeneralSerialNumber
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtInputDefaultIndex
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtInputMediaDimFeedDirDeclared
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtInputMaxCapacity
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtInputCurrentLevel
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtInputMediaName
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtInputName
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"



Turner                 Printer MIB V2                  [Page 131]


INTERNET DRAFT          Printer MIB              January 22, 1999



       OBJECT    prtInputSecurity
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtInputMediaWeight
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtInputMediaType
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtInputMediaColor
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtInputMediaFormParts
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtInputMediaLoadTimeout
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtInputNextIndex
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtOutputDefaultIndex
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtOutputMaxCapacity
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtOutputRemainingCapacity
       MIN-ACCESS  read-only
       DESCRIPTION


Turner                 Printer MIB V2                  [Page 132]


INTERNET DRAFT          Printer MIB              January 22, 1999



         "It is conformant to implement this object as read-only"

       OBJECT    prtOutputName
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtOutputSecurity
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtOutputMaxDimFeedDir
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtOutputMaxDimXFeedDir
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtOutputMinDimFeedDir
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtOutputMinDimXFeedDir
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtOutputStackingOrder
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtOutputPageDeliveryOrientation
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtOutputBursting
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtOutputDecollating


Turner                 Printer MIB V2                  [Page 133]


INTERNET DRAFT          Printer MIB              January 22, 1999



       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtOutputPageCollated
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtOutputOffsetStacking
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtMarkerDefaultIndex
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtMarkerSuppliesMaxCapacity
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtMarkerSuppliesLevel
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtMediaPathDefaultIndex
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtChannelCurrentJobCntlLangIndex
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtChannelDefaultPageDescLangIndex
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtChannelState
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"


Turner                 Printer MIB V2                  [Page 134]


INTERNET DRAFT          Printer MIB              January 22, 1999




       OBJECT    prtChannelIfIndex
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtInterpreterDefaultOrientation
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtInterpreterDefaultCharSetIn
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtInterpreterDefaultCharSetOut
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtConsoleLocalization
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtConsoleDisable
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT    prtConsoleDisplayBufferText
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT      prtConsoleOnTime
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       OBJECT      prtConsoleOffTime
       MIN-ACCESS  read-only
       DESCRIPTION
         "It is conformant to implement this object as read-only"

       GROUP       prtResponsiblePartyGroup
       DESCRIPTION


Turner                 Printer MIB V2                  [Page 135]


INTERNET DRAFT          Printer MIB              January 22, 1999



         "This group is unconditionally optional."

       GROUP       prtExtendedInputGroup
       DESCRIPTION
         "This group is unconditionally optional."

       GROUP       prtInputMediaGroup
       DESCRIPTION
         "This group is unconditionally optional."

       GROUP       prtExtendedOutputGroup
       DESCRIPTION
         "This group is unconditionally optional."

       GROUP       prtOutputDimensionsGroup
       DESCRIPTION
         "This group is unconditionally optional."

       GROUP       prtOutputFeaturesGroup
       DESCRIPTION
         "This group is unconditionally optional."

       GROUP       prtMarkerSuppliesGroup
       DESCRIPTION
         "This group is unconditionally optional."

       GROUP       prtMarkerColorantGroup
       DESCRIPTION
         "This group is unconditionally optional."

       GROUP       prtAuxiliarySheetGroup
       DESCRIPTION
         "This group is unconditionally optional."

       GROUP       prtInputSwitchingGroup
       DESCRIPTION
         "This group is unconditionally optional."

    ::= { prtMIBConformance 1 }

prtMIBGroups      OBJECT IDENTIFIER ::= { prtMIBConformance 2 }

prtGeneralGroup OBJECT-GROUP
    OBJECTS { prtGeneralConfigChanges,
              prtGeneralCurrentLocalization,
              prtGeneralReset, prtCoverDescription,
              prtCoverStatus,
              prtLocalizationLanguage, prtLocalizationCountry,


Turner                 Printer MIB V2                  [Page 136]


INTERNET DRAFT          Printer MIB              January 22, 1999



              prtLocalizationCharacterSet, prtStorageRefIndex,
              prtDeviceRefIndex, prtGeneralPrinterName,
              prtGeneralSerialNumber }
    STATUS  current
    DESCRIPTION
        "The general printer group."
    ::= { prtMIBGroups 1 }

prtResponsiblePartyGroup OBJECT-GROUP
    OBJECTS { prtGeneralCurrentOperator, prtGeneralServicePerson
}
    STATUS  current
    DESCRIPTION
         "The responsible party group contains contact
         information for humans responsible for the printer."
    ::= { prtMIBGroups 2 }

prtInputGroup OBJECT-GROUP
     OBJECTS { prtInputDefaultIndex, prtInputType,
               prtInputDimUnit, prtInputMediaDimFeedDirDeclared,
               prtInputMediaDimXFeedDirDeclared,
               prtInputMediaDimFeedDirChosen,
               prtInputMediaDimXFeedDirChosen,
               prtInputCapacityUnit, prtInputMaxCapacity,
               prtInputCurrentLevel, prtInputStatus,
               prtInputMediaName }
    STATUS  current
    DESCRIPTION
        "The input group."
    ::= { prtMIBGroups 3 }

prtExtendedInputGroup OBJECT-GROUP
     OBJECTS { prtInputName, prtInputVendorName, prtInputModel,
               prtInputVersion, prtInputSerialNumber,
               prtInputDescription, prtInputSecurity }
    STATUS  current
    DESCRIPTION
        "The extended input group."
    ::= { prtMIBGroups 4 }

prtInputMediaGroup OBJECT-GROUP
    OBJECTS { prtInputMediaWeight, prtInputMediaType,
              prtInputMediaColor, prtInputMediaFormParts }
    STATUS  current
    DESCRIPTION
        "The input media group."
    ::= { prtMIBGroups 5 }



Turner                 Printer MIB V2                  [Page 137]


INTERNET DRAFT          Printer MIB              January 22, 1999



prtOutputGroup OBJECT-GROUP
    OBJECTS { prtOutputDefaultIndex, prtOutputType,
              prtOutputCapacityUnit, prtOutputMaxCapacity,
              prtOutputRemainingCapacity,  prtOutputStatus }
    STATUS  current
    DESCRIPTION
        "The output group."
    ::= { prtMIBGroups 6 }

prtExtendedOutputGroup OBJECT-GROUP
    OBJECTS { prtOutputName, prtOutputVendorName, prtOutputModel,
              prtOutputVersion, prtOutputSerialNumber,
              prtOutputDescription, prtOutputSecurity }
    STATUS  current
    DESCRIPTION
        "The extended output group."
    ::= { prtMIBGroups 7 }

prtOutputDimensionsGroup OBJECT-GROUP
    OBJECTS { prtOutputDimUnit, prtOutputMaxDimFeedDir,
              prtOutputMaxDimXFeedDir, prtOutputMinDimFeedDir,
              prtOutputMinDimXFeedDir }
    STATUS  current
    DESCRIPTION
        "The output dimensions group"
    ::= { prtMIBGroups 8 }

prtOutputFeaturesGroup OBJECT-GROUP
    OBJECTS { prtOutputStackingOrder,
              prtOutputPageDeliveryOrientation,
              prtOutputBursting,
              prtOutputDecollating, prtOutputPageCollated,
              prtOutputOffsetStacking }
    STATUS  current
    DESCRIPTION
        "The output features group."
    ::= { prtMIBGroups 9 }

prtMarkerGroup OBJECT-GROUP
    OBJECTS { prtMarkerDefaultIndex, prtMarkerMarkTech,
              prtMarkerCounterUnit, prtMarkerLifeCount,
              prtMarkerPowerOnCount, prtMarkerProcessColorants,
              prtMarkerSpotColorants,
              prtMarkerAddressabilityUnit,
              prtMarkerAddressabilityFeedDir,
              prtMarkerAddressabilityXFeedDir,
              prtMarkerNorthMargin,
              prtMarkerSouthMargin, prtMarkerWestMargin,


Turner                 Printer MIB V2                  [Page 138]


INTERNET DRAFT          Printer MIB              January 22, 1999



              prtMarkerEastMargin, prtMarkerStatus }
    STATUS  current
    DESCRIPTION
        "The marker group."
    ::= { prtMIBGroups 10 }

prtMarkerSuppliesGroup OBJECT-GROUP
    OBJECTS { prtMarkerSuppliesMarkerIndex,
              prtMarkerSuppliesColorantIndex,
              prtMarkerSuppliesClass,
              prtMarkerSuppliesType,
              prtMarkerSuppliesDescription,
              prtMarkerSuppliesSupplyUnit,
              prtMarkerSuppliesMaxCapacity,
              prtMarkerSuppliesLevel }
    STATUS  current
    DESCRIPTION
        "The marker supplies group."
    ::= { prtMIBGroups 11 }

prtMarkerColorantGroup OBJECT-GROUP
    OBJECTS { prtMarkerColorantMarkerIndex,
              prtMarkerColorantRole,
              prtMarkerColorantValue, prtMarkerColorantTonality }
    STATUS  current
    DESCRIPTION
        "The marker colorant group."
    ::= { prtMIBGroups 12 }

prtMediaPathGroup OBJECT-GROUP
    OBJECTS { prtMediaPathDefaultIndex,
              prtMediaPathMaxSpeedPrintUnit,
              prtMediaPathMediaSizeUnit, prtMediaPathMaxSpeed,
              prtMediaPathMaxMediaFeedDir,
              prtMediaPathMaxMediaXFeedDir,
              prtMediaPathMinMediaFeedDir,
              prtMediaPathMinMediaXFeedDir, prtMediaPathType,
              prtMediaPathDescription, prtMediaPathStatus}
    STATUS  current
    DESCRIPTION
        "The media path group."
    ::= { prtMIBGroups 13 }

prtChannelGroup OBJECT-GROUP
    OBJECTS { prtChannelType, prtChannelProtocolVersion,
              prtChannelCurrentJobCntlLangIndex,
              prtChannelDefaultPageDescLangIndex,
              prtChannelState,


Turner                 Printer MIB V2                  [Page 139]


INTERNET DRAFT          Printer MIB              January 22, 1999



              prtChannelIfIndex, prtChannelStatus,
              prtChannelInformation }
    STATUS  current
    DESCRIPTION
        "The channel group."
    ::= { prtMIBGroups 14 }

prtInterpreterGroup OBJECT-GROUP
    OBJECTS { prtInterpreterLangFamily, prtInterpreterLangLevel,
              prtInterpreterLangVersion,
              prtInterpreterDescription,
              prtInterpreterVersion,
              prtInterpreterDefaultOrientation,
              prtInterpreterFeedAddressability,
              prtInterpreterXFeedAddressability,
              prtInterpreterDefaultCharSetIn,
              prtInterpreterDefaultCharSetOut,
              prtInterpreterTwoWay }
    STATUS  current
    DESCRIPTION
        "The interpreter group."
    ::= { prtMIBGroups 15 }

prtConsoleGroup OBJECT-GROUP
    OBJECTS { prtConsoleLocalization,
              prtConsoleNumberOfDisplayLines,
              prtConsoleNumberOfDisplayChars, prtConsoleDisable,
              prtConsoleDisplayBufferText, prtConsoleOnTime,
              prtConsoleOffTime, prtConsoleColor,
              prtConsoleDescription }
    STATUS  current
    DESCRIPTION
        "The console group."
    ::= { prtMIBGroups 16 }

prtAlertTableGroup OBJECT-GROUP
    OBJECTS { prtAlertIndex, prtAlertCriticalEvents,
              prtAlertAllEvents,
              prtAlertSeverityLevel, prtAlertTrainingLevel,
              prtAlertGroup, prtAlertGroupIndex,
              prtAlertLocation, prtAlertCode,
              prtAlertDescription, prtAlertTime }
    STATUS  current
    DESCRIPTION
        "The alert table group."
    ::= { prtMIBGroups 17 }

--


Turner                 Printer MIB V2                  [Page 140]


INTERNET DRAFT          Printer MIB              January 22, 1999



-- prtAlertTimeGroup has been DEPRECATED (prtMIBGroups 18 )
--

prtAuxiliarySheetGroup OBJECT-GROUP
    OBJECTS { prtAuxiliarySheetStartupPage,
              prtAuxiliarySheetBannerPage }
    STATUS  current
    DESCRIPTION
        "The auxiliary sheet group."
    ::= { prtMIBGroups 19 }

prtInputSwitchingGroup OBJECT-GROUP
    OBJECTS { prtInputMediaLoadTimeout, prtInputNextIndex }
    STATUS  current
    DESCRIPTION
     "The input switching group."
    ::= { prtMIBGroups 20 }


END






























Turner                 Printer MIB V2                  [Page 141]


INTERNET DRAFT          Printer MIB              January 22, 1999




Appendix A - Glossary of Terms

Addressability - On the marker, the number of distinct marking
units (pels) per unit of addressability unit that can be set; for
example, 300 dots per inch is expressed as 300 per 1000
Thousandths Of Inches and 4 dots per millimeter is 4 per 1000
Micrometers. Addressability is not resolution because marks that
are one addressability position apart may not be independently
resolvable by the eye due to factors such as gain in the area of
marks so they overlap or nearly touch.

Alert - A reportable event for which there is an entry in the
alert table.

Bin - An output sub-unit which may or may not be removable.

Binary Change Event - An event which comes in pairs; the leading
edge event and the trailing edge event. The leading edge event
enters a state from which there is only one exit. A binary change
event may be critical or non-critical. See unary change event.

Bursting - The process by which continuous media is separated
into individual sheets, typically by bursting along pre-formed
perforations.

Channel - A term used to describe a single source of data which
is presented to a printer.  The model that we use in describing a
printer allows for an arbitrary number of channels.  Multiple
channels can exist on the same physical port.  This is commonly
done over Ethernet ports where EtherTalk, TCP/IP, and SPX/IPX
protocols can be supplying different data streams simultaneously
to a single printer on the same physical port.

Collation - In multiple copy output, placing the pages from
separate copies into separate ordered sets, ready for binding.

Control Language - A data syntax or language for controlling the
printer through the print data channel.

Critical Alert - An alert triggered by an event which leads to a
state in which printing is no longer possible; the printer is
stopped.

Decollating - The process by which the individual parts within a
multi-part form are separated and sorted into separate stacks for
each part.



Turner                 Printer MIB V2                  [Page 142]


INTERNET DRAFT          Printer MIB              January 22, 1999



Description - Information about the configuration and
capabilities of the printer and its various sub-units.

DPA - ISO 10175 Document Printing Application standard.  A
standard for a client server protocol for a print system,
including (1) submitting print jobs to and (2) managing print
jobs in a spooler.

Event - A state change in the printer.

Group - A collection of objects that represent a type of sub-unit
of the printer.

IANA - Internet Assigned Numbers Authority.  See STD 2, RFC 1700.

Idempotent - Idempotence is the property of an operation that
results in the same state no matter how many times it is executed
(at least once).  This is a property that is shared by true
databases in which operations on data items only change the state
of the data item and do not have other side effects.  Because the
SNMP data model is that of operations on a database, SNMP MIB
objects should be assumed to be idempotent.  If a MIB object is
defined in a non-idempotent way, the this data model can break in
subtle ways when faced with packet loss, multiple managers, and
other common conditions.

In order to fulfill the common need for actions to result from
SNMP Set operations, SNMP MIB objects can be modeled such that
the change in state from one state to another has the side effect
of causing an action.  It is important to note that with this
model, an SNMP operation that sets a value equal to its current
value will cause no action.  This retains the idempotence of a
single command, while allowing actions to be initiated by SNMP
SET requests.

Input - A tray or bin from which instances of the media are
obtained and fed into the Media Path.

Interpreter - The embodiment of an algorithm that processes a
data stream consisting of a Page Description Language (PDL)
and/or a Control Language.

Localization - The specification of human language, country, and
character set needed to present information to people in their
native languages.

Management Application (a.k.a. Manager) - A program which queries
and controls one or more managed nodes.


Turner                 Printer MIB V2                  [Page 143]


INTERNET DRAFT          Printer MIB              January 22, 1999



Management Station - A physical computer on which one or more
management applications can run.

Media Path - The mechanisms that transport instances of the media
from an input, through the marker, possibly through media buffers
and duplex pathways, out to the output with optional finishing
applied.  The inputs and outputs are not part of the Media Path.

Non-critical Alert - An alert triggered by a reportable event
which does not lead to a state in which printing is no longer
possible; such an alert may lead to a state from which printing
may no longer be possible in the future, such as the low toner
state or the alert may be pure informational, such as a
configuration change at the printer.

Output - A bin or stacker which accepts instances of media that
have been processed by a printer.

Page Description Language (PDL) - A data syntax or language for
the electronic representation of a document as a sequence of page
images.

Printer - A physical device that takes media from an input
source, produces marks on that media according to some page
description or page control language and puts the result in some
output destination, possibly with finishing applied.

Printing - The entire process of producing a printed document
from generation of the file to be printed, choosing printing
properties, selection of a printer, routing, queuing, resource
management, scheduling, and finally printing including notifying
the user.

Reportable event - An event that is deemed of interest to a
management station watching the printer.

Status - Information regarding the current operating state of the
printer and its various sub-units. This is an abstraction of the
exact physical condition of the printer.

Sub-mechanism - A distinguishable part of a sub-unit.

Sub-unit - A part of the printer which may be a physical part,
such as one of the input sources or a logical part such as an
interpreter.

Tray - An input sub-unit which is typically removable.



Turner                 Printer MIB V2                  [Page 144]


INTERNET DRAFT          Printer MIB              January 22, 1999



Unary Change Event - An event that indicates a change of state of
the printer, but to a state which is (often) just as valid as the
state that was left, and from which no return is necessary. See
binary change event.

Visible state - The portion of the state of the printer that can
be examined by a management application.

Warning - A non-critical alert. See non-critical alert.









































Turner                 Printer MIB V2                  [Page 145]


INTERNET DRAFT          Printer MIB              January 22, 1999




Appendix B - Media Size Names from ISO/IEC 10175 Document
Printing Architecture

For the convenience of management application developers, this
appendix lists the standardized media size names from ISO/IEC
10175 Document Printing Application (DPA). Management
applications that present a dialogue for choosing or displaying
media size are encouraged to present relevant names from this
list to avoid requiring the user to remember the physical
dimensions used to describe the size of the media. A printer
implementing the Printer MIB has no knowledge of these names,
however; all media sizes in the MIB are given in terms of media
dimensions as the values of prtMediaDimFeedDir and
prtInputChosenMediaDimXFeedDir.


String name               Description

other

unknown
na-letter or letter     North American letter
                          size: 8.5 by 11 inches
na-legal or legal       North American legal
                          size:  8.5 by 14 inches
na-10x13-envelope       North American 10x13 envelope
                           size:  10 by 13 inches
na-9x12-envelope        North American 9x12 envelope
                           size:  9 by 12 inches
na-number-10-envelope   North American number 10 business
envelope
                           size:  4.125 by 9.5 inches
na-7x9-envelope         North American 7x9
                           size:  7 by 9 inches
na-9x11-envelope        North American 9x11
                           size: 9 by 11 inches
na-10x14-envelope       North American 10x14 envelope
                           size: 10 by 14 inches
na-number-9-envelope    North American number 9 business envelope
na-6x9-envelope         North American 6x9 envelope
                           size:  6 by 9 inches
na-10x15-envelope       North American 10x15 envelope
                           size: 10 by 15 inches
a                       engineering A size 8.5 inches by 11
inches
b                       engineering B size 11 inches by 17 inches
c                       engineering C size 17 inches by 22 inches


Turner                 Printer MIB V2                  [Page 146]


INTERNET DRAFT          Printer MIB              January 22, 1999



d                       engineering D size 22 inches by 34 inches
e                       engineering E size 34 inches by 44 inches
iso-a0                  ISO A0  size:  841 mm by 1189 mm
iso-a1                  ISO A1  size:  594 mm by  841 mm
iso-a2                  ISO A2  size:  420 mm by  594 mm
iso-a3                  ISO A3  size:  297 mm by  420 mm
iso-a4                  ISO A4  size:  210 mm by  297 mm
iso-a5                  ISO A5  size:  148 mm by  210 mm
iso-a6                  ISO A6  size:  105 mm by  148 mm
iso-a7                  ISO A7  size:   74 mm by  105 mm
iso-a8                  ISO A8  size:   52 mm by   74 mm
iso-a9                  ISO A9  size:   37 mm by   52 mm
iso-a10                 ISO A10 size:   26 mm by   37 mm
iso-b0                  ISO B0  size: 1000 mm by 1414 mm
iso-b1                  ISO B1  size:  707 mm by 1000 mm
iso-b2                  ISO B2  size:  500 mm by  707 mm
iso-b3                  ISO B3  size:  353 mm by  500 mm
iso-b4                  ISO B4  size:  250 mm by  353 mm
iso-b5                  ISO B5  size:  176 mm by  250 mm
iso-b6                  ISO B6  size:  125 mm by  176 mm
iso-b7                  ISO B7  size:   88 mm by  125 mm
iso-b8                  ISO B8  size:   62 mm by   88 mm
iso-b9                  ISO B9  size:   44 mm by   62 mm
iso-b10                 ISO B10 size:   31 mm by   44 mm
iso-c0                  ISO C0 size:   917 mm by 1297 mm
iso-c1                  ISO C1 size:   648 mm by  917 mm
iso-c2                  ISO C2 size:   458 mm by  648 mm
iso-c3                  ISO C3 size:   324 mm by  458 mm
iso-c4                  ISO C4 size:   229 mm by  324 mm
iso-c5                  ISO C5 size:   162 mm by  229 mm
iso-c6                  ISO C6 size:   114 mm by  162 mm
iso-c7                  ISO C7 size:    81 mm by  114 mm
iso-c8                  ISO C8 size:    57 mm by   81 mm
iso-designated          ISO Designated Long
                            size:  110 mm by 220 mm
jis-b0                  JIS B0  size  1030 mm by 1456 mm
jis-b1                  JIS B1  size   728 mm by 1030 mm
jis-b2                  JIS B2  size   515 mm by  728 mm
jis-b3                  JIS B3  size   364 mm by  515 mm
jis-b4                  JIS B4  size   257 mm by  364 mm
jis-b5                  JIS B5  size   182 mm by  257 mm
jis-b6                  JIS B6  size   128 mm by  182 mm
jis-b7                  JIS B7  size    91 mm by  128 mm
jis-b8                  JIS B8  size    64 mm by   91 mm
jis-b9                  JIS B9  size    45 mm by   64 mm
jis-b10                 JIS B10 size    32 mm by   45 mm




Turner                 Printer MIB V2                  [Page 147]


INTERNET DRAFT          Printer MIB              January 22, 1999





















































Turner                 Printer MIB V2                  [Page 148]


INTERNET DRAFT          Printer MIB              January 22, 1999




Appendix C - Media Names

For the convenience of management application developers, this
appendix lists the standardized media names from ISO/IEC 10175
Document Printing Application (DPA). Management applications that
present a dialogue for choosing media may wish to use these names
as an alternative to separately specifying, size, color, and/or
type. Using standard media names will mean that a single
management application dealing with printers from different
vendors and under different system mangers will tend to use the
same names for the same media. If selection of media by name is
used, the attributes (size, type or color) implied by the name
must be explicitly mapped to the appropriate object
(prtInputDeclared-MediaDimFeedDir,
prtInputDeclaredMediaDimXFeedDir, prtInputMediaType and
prtInputMediaColor) in the MIB. The object prtInputMediaName is
intended for display to an operator and is purely descriptive.
The value in prtInputMediaName is not interpreted by the printer
so using a standard name for this value will not change any of
the other media attributes nor will it cause an alert if the
media in the input sub-unit does not match the name.


  Simple Name                 Descriptor Text

  other
  unknown
  iso-a4-white        Specifies the ISO A4 white medium with
                        size: 210 mm by 297 mm as defined in ISO
                        216
  iso-a4-coloured     Specifies the ISO A4 colored medium with
                        size: 210 mm by 297 mm as defined in ISO
                        216
  iso-a4-transparent  Specifies the ISO A4 transparent medium
                        with size: 210 mm by 297 mm as defined in
                        ISO 216
  iso-a3-white        Specifies the ISO A3 white medium with
                        size: 297 mm by 420 mm as defined in ISO
                        216
  iso-a3-coloured     Specifies the ISO A3 colored medium with
                        size: 297 mm by 420 mm as defined in ISO
                        216
  iso-a5-white        Specifies the ISO A5 white medium with
                        size: 148 mm by 210 mm as defined in ISO
                        216
  iso-a5-coloured     Specifies the ISO A5 colored medium with
                        size: 148 mm by 210 mm as defined in ISO


Turner                 Printer MIB V2                  [Page 149]


INTERNET DRAFT          Printer MIB              January 22, 1999



                        216
  iso-b4-white        Specifies the ISO B4 white medium with
                        size: 250 mm by 353 mm as defined in ISO
                        216
  iso-b4-coloured     Specifies the ISO B4 colored medium with
                        size: 250 mm by 353 mm as defined in ISO
                        216
  iso-b5-white        Specifies the ISO B5 white medium with
                        size: 176 mm by 250 mm as defined in ISO
                        216
  iso-b5-coloured     Specifies the ISO B5 colored medium with
                        size: 176 mm by 250 mm as defined in ISO
                        216
  jis-b4-white        Specifies the JIS B4 white medium with
                        size: 257 mm by 364 mm as defined in JIS
                        P0138
  jis-b4-coloured     Specifies the JIS B4 colored medium with
                        size: 257 mm by 364 mm as defined in JIS
                        P0138
  jis-b5-white        Specifies the JIS B5 white medium with
                        size: 182 mm by 257 mm as defined in JIS
                        P0138
  jis-b5-coloured     Specifies the JIS B5 colored medium with
                        size: 182 mm by 257 mm as defined in JIS
                        P0138

The following standard values are defined for North American
media:

  na-letter-white    Specifies the North American letter white
                        medium with size: 8.5 inches by 11 inches
  na-letter-coloured Specifies the North American letter colored
                        medium with size: 8.5 inches by 11 inches
  na-letter-transparent
                     Specifies the North American letter
                        transparent medium with size: 8.5 inches
                        by 11 inches
  na-legal-white     Specifies the North American legal white
                        medium with size: 8.5 inches by 14 inches
  na-legal-coloured  Specifies the North American legal colored
                        medium with size: 8.5 inches by 14 inches

  The following standard values are defined for envelopes:

  iso-b5-envelope    Specifies the ISO B5 envelope medium
                        with size: 176 mm by 250 mm
                        as defined in ISO 216 and ISO 269
  iso-b4-envelope    Specifies the ISO B4 envelope medium


Turner                 Printer MIB V2                  [Page 150]


INTERNET DRAFT          Printer MIB              January 22, 1999



                        with size: 250 mm by 353 mm
                        as defined in ISO 216
  iso-c4-envelope    Specifies the ISO C4 envelope medium
                        with size: 229 mm by 324 mm
                        as defined in ISO 216 and ISO 269
  iso-c5-envelope    Specifies the ISO C5 envelope medium
                        with size: 162 mm by 229 mm
                        as defined in ISO 269
  iso-designated-long-envelope
                     Specifies the ISO Designated Long envelope
                        medium with size: 110 mm by 220 mm
                        as defined in ISO 269

  na-10x13-envelope  Specifies the North American 10x13 envelope
                        medium with size: 10 inches by 13 inches
  na-9x12-envelope   Specifies the North American 9x12 envelope
                        medium with size: 9 inches by 12 inches
  na-number-10-envelope
                     Specifies the North American number 10
                        business envelope medium with size: 4.125
                        inches by 9.5 inches
  na-7x9-envelope    Specifies the North American 7x9 inch
                        envelope

  na-9x11-envelope   Specifies the North American 9x11 inch
                        envelope

  na-10x14-envelope  Specifies the North American 10x14 inch
                        envelope

  na-number-9-envelope
                     Specifies the North American number 9
                        business envelope
  na-6x9-envelope    Specifies the North American 6x9 inch
                        envelope

  na-10x15-envelope  Specifies the North American 10x15 inch
                        envelope


The following standard values are defined for the less commonly
used media (white-only):

  iso-a0-white  Specifies the ISO A0 white medium
                  with size:  841 mm by 1189 mm
                  as defined in ISO 216
  iso-a1-white  Specifies the ISO A1 white medium
                  with size:  594 mm by 841 mm


Turner                 Printer MIB V2                  [Page 151]


INTERNET DRAFT          Printer MIB              January 22, 1999



                  as defined in ISO 216
  iso-a2-white  Specifies the ISO A2 white medium
                  with size:  420 mm by 594 mm
                  as defined in ISO 216
  iso-a6-white  Specifies the ISO A6 white medium
                  with size:  105 mm by 148 mm
                  as defined in ISO 216
  iso-a7-white  Specifies the ISO A7 white medium
                  with size:  74 mm by 105 mm
                  as defined in ISO 216
  iso-a8-white  Specifies the ISO A8 white medium
                  with size:  52 mm by 74 mm
                  as defined in ISO 216
  iso-a9-white  Specifies the ISO A9 white medium
                  with size:  39 mm by 52 mm
                  as defined in ISO 216
  iso-10-white  Specifies the ISO A10 white medium
                  with size:  26 mm by 37 mm
                  as defined in ISO 216
  iso-b0-white  Specifies the ISO B0 white medium
                  with size: 1000 mm by 1414 mm
                  as defined in ISO 216
  iso-b1-white  Specifies the ISO B1 white medium
                  with size:  707 mm by 1000 mm
                  as defined in ISO 216
  iso-b2-white  Specifies the ISO B2 white medium
                  with size:  500 mm by 707 mm
                  as defined in ISO 216
  iso-b3-white  Specifies the ISO B3 white medium
                  with size:  353 mm by 500 mm
                  as defined in ISO 216
  iso-b6-white  Specifies the ISO B6 white medium
                  with size:  125 mm by 176 mm i
                  as defined in ISO 216
  iso-b7-white  Specifies the ISO B7 white medium
                  with size:  88 mm by 125 mm
                  as defined in ISO 216
  iso-b8-white  Specifies the ISO B8 white medium
                  with size:  62 mm by 88 mm
                  as defined in ISO 216
  iso-b9-white  Specifies the ISO B9 white medium
                  with size:  44 mm by 62 mm
                  as defined in ISO 216
  iso-b10-white Specifies the ISO B10 white medium
                  with size:  31 mm by 44 mm
                  as defined in ISO 216
  jis-b0-white  Specifies the JIS B0 white medium with size:
                  1030 mm by 1456 mm


Turner                 Printer MIB V2                  [Page 152]


INTERNET DRAFT          Printer MIB              January 22, 1999



  jis-b1-white  Specifies the JIS B1 white medium with size:
                  728 mm by 1030 mm
  jis-b2-white  Specifies the JIS B2 white medium with size:
                  515 mm by 728 mm
  jis-b3-white  Specifies the JIS B3 white medium with size:
                  364 mm by 515 mm
  jis-b6-white  Specifies the JIS B6 white medium with size:
                  257 mm by 364 mm
  jis-b7-white  Specifies the JIS B7 white medium with size:
                  182 mm by 257 mm
  jis-b8-white  Specifies the JIS B8 white medium with size:
                  128 mm by 182 mm
  jis-b9-white  Specifies the JIS B9 white medium with size:
                  91 mm by 128 mm
  jis-b10-white Specifies the JIS B10 white medium with size:
                  64 mm by 91 mm

The following standard values are defined for engineering media:
       a        Specifies the engineering A size medium with
                   size: 8.5 inches by 11 inches
       b        Specifies the engineering B size medium with
                   size: 11 inches by 17 inches
       c        Specifies the engineering C size medium with
                   size: 17 inches by 22 inches
       d        Specifies the engineering D size medium with
                    size: 22 inches by 34 inches
       e        Specifies the engineering E size medium with
                    size: 34 inches by 44 inches






















Turner                 Printer MIB V2                  [Page 153]


INTERNET DRAFT          Printer MIB              January 22, 1999




Appendix D - Roles of Users

Background

The need for "Role Models" stemmed in large part from the need to
understand the importance of any given proposed object for the
MIB.  Many times the real world need for a proposed object would
be debated within the group; the debate would typically result in
the need to describe the potential usage of the object in terms
of a "live" person performing some type of printing-related task.

Determining the value of a proposed object through identification
of the associated human users was found to be so common that a
more formalized model was required for consistent analysis.  The
model describing categories of human-oriented tasks is called
"Role Models" in this document.

In developing the Role Models it was necessary to identify the
common, primary tasks that humans typically face when interacting
with a printer and its related printing system(s).  It was
expected that certain kinds of tasks would serve to identify the
various Role Models.

In presenting the set of Role Models, the set of "Common Print
System Tasks" are first presented, followed by the set of Role
Model definitions.  Finally, a simple matrix is presented in
which Role Models and Tasks are cross-compared.

Common Print System Tasks

Upon researching the many tasks encountered by humans in dealing
with printers and printing systems, the following were found to
be pervasive within any operating environment:


Printer job state - Determine the status of a job without a
printer.

Printer capabilities - Determine the current capabilities of a
printer, for example, the available media sizes, two-sided
printing, a particular type of interpreter, etc.

Printer job submission - Submit a print job to a printer.

Printer job removal - Remove a job from a printer.




Turner                 Printer MIB V2                  [Page 154]


INTERNET DRAFT          Printer MIB              January 22, 1999



Notification of events - Receive notification of the existence of
a defined printer event.  An event can be of many types,
including warnings, errors, job stage completion (e.g., "job
done"), etc.

Printer configuration - Query the current configuration of a
printer.

Printer consumables - Determine the current state of any and all
consumables within a printer.

Print job identification - Determine the identification of a job
within a printer.

Internal printer status - Determine the current status of the
printer.

Printer identification - Determine the identity of a printer.
Printer location - Determine the physical location of a printer.

Local system configuration - Determine various aspects of the
current configuration of the local system involved with the
operation of a printer.

These "tasks" cover a large spectrum of requirements surrounding
the operation of a printer in a network environment.  This list
serves as the basis for defining the various Role Models
described below.

Proposed Role Models

Following is the list of "Role Models" used to evaluate the
requirements for any given Printer MIB object.  Note that the
keyword enclosed in parentheses represents an abbreviation for
the particular Role Model in the matrix described later in this
document.

User  (USER) - A person or application that submits print jobs to
the printer; typically viewed as the "end user" within the
overall printing environment.

Operator  (OP) - A person responsible for maintaining a printer
on a day-to-day basis, including such tasks as filling empty
media trays, emptying full output trays, replacing toner
cartridges, clearing simple paper jams, etc.

Technician  (TECH) - A person responsible for repairing a
malfunctioning printer, performing routine preventive


Turner                 Printer MIB V2                  [Page 155]


INTERNET DRAFT          Printer MIB              January 22, 1999



maintenance, and other tasks that typically require advanced
training on the printer internals.  An example of a "technician"
would be a manufacturer's Field Service representative, or other
person formally trained by the manufacturer or similar
representative.

System Manager  (MGR) - A person responsible for configuration
and troubleshooting of components involved in the overall
printing environment, including printers, print queues and
network connectivity issues.  This person is typically
responsible for ensuring the overall operational integrity of the
print system components, and is typically viewed as the central
point of coordination among all other Role Models.

Help Desk  (HELP) - A person responsible for supporting Users in
their printing needs, including training Users and
troubleshooting Users' printing problems.

Asset Manager  (AM) - A person responsible for managing an
organization's printing system assets (primarily printers).  Such
a person needs to be able to identify and track the location of
printing assets on an ongoing basis.

Capacity Planner  (CP) - A person responsible for tracking the
usage of printing resources on an ongoing basis for the purpose
of planning printer acquisitions and/or placement of printers
based on usage trends.

Installer  (INST) - A person or application responsible for
installing or configuring printing system components on a local
system.

Accountant  (ACCT) - A person responsible for tracking the usage
of printing resources on an ongoing basis for the purpose of
charging Users for resources used.

Matrix of Common Print System Tasks and Role Models

To better understand the relationship between the set of defined
"Common Print System Tasks" and the various "Role Models," the
following matrix is provided.

It is important to recognize that many of the tasks will appear
to be applicable to many of the Role Models.  However, when
considering the actual context of a task, it is very important to
realize that often the actual context of a task is such that the
Role Model can change.



Turner                 Printer MIB V2                  [Page 156]


INTERNET DRAFT          Printer MIB              January 22, 1999



For example, it is obvious that a "System Manager" must be able
to submit print jobs to a printer; however, when submitting a
print job, a person identified as a "System Manager" is actually
operating in the context of a "User" in this case; hence, the
requirement to submit a print job is not listed as a requirement
for a System Manager.

Conversely, while a "User" must be able to remove a job
previously submitted to a printer, an "Operator" is often
expected to be able to remove any print job from any printer;
hence, print job removal is a (subtly different) requirement for
both the "User" and "Operator" Role Models.


                        Role Models
                         -----------

   Requirement Area     USER OP TECH MGR HELP  AM  CP INST ACCT
Print job status         xx  xx   xx  xx   xx
Printer capabilities     xx           xx   xx
Print job submission     xx
Print job removal        xx  xx
Notification of events       xx   xx
Printer configuration                 xx               xx
Printer consumables          xx                    xx  xx
Print job identification     xx       xx   xx      xx       xx
Internal printer status      xx   xx  xx
Printer identification       xx   xx  xx   xx  xx  xx  xx
Printer location                                   xx
Local system configuration            xx               xx




















Turner                 Printer MIB V2                  [Page 157]


INTERNET DRAFT          Printer MIB              January 22, 1999




Appendix E - Overall Printer Status Table


The Status Table was generated first in landscape format and is
easier to read in this format. Because a table in landscape
format can not be included in this document, the table has been
converted into portrait format and split into three different
sections. The three sections are: 1) the hrDeviceStatus,
hrPrinterStuatus and hrPrinterDetectedErrorState for each state,
2) the prtAlertTable for each state and 3) the respective SubUnit
status for each state. The Status Table in landscape format can
be found in a file with a name similar to Top 25 Errors at
"ftp.pwg.org" in the directory /pub/pwg/pmp/contributions.

The following table defines a suggested relationship between
various printer states and the variables Printer hrDeviceStatus,
hrPrinterStatus, hrPrinterDetectedErrorState, prtAlertGroup,
prtAlertCode and various sub-unit status variables
(prtInputStatus, prtOutputStatus, prtMarkerStatus,
prtMediaPathStatus and prtChannelStatus). This table is the
recommended implementation of these variables. It is provided to
guide implementors of this MIB and users of the MIB by providing
a sample set of states and the variable values that are expected
to be produced as result of that state.

This information supplements that provided in Section 2.2.13.2
"Overall Printer Status". This is not an exhaustive list rather
it is a guideline. More detailed status, if needed, should be
obtained from the alert table and the sub-unit status variables.


                   |       General Printer Status               |
                   |--------------------------------------------+
                   |            |              |hrPrinter       |
Printer            |hrDevice    |hrPrinter     |Detected        |
State              |Status      |Status        |ErrorState      |
-------------------+------------+--------------+----------------+
Normal or idle     |running (2) |idle (3)      |(0x0000)        |
(no binary alerts) |            |              |                |
                   |            |              |                |
Printing           |running (2) |printing (4)  |(0x0000)        |
(no binary alerts) |            |              |                |
                   |            |              |                |
Off-line           |down (5)    |other (1)     |offline         |
                   |            |              |  (0x0200)      |
                   |            |              |                |
Standby or Power   |running (2) |other (1)     |(0x0000)        |


Turner                 Printer MIB V2                  [Page 158]


INTERNET DRAFT          Printer MIB              January 22, 1999



Saver Mode         |            |              |                |
                   |            |              |                |
Initial Power Up   |            |              |                |
(no binary alerts, |down (5)    |warmup (5)    |offline         |
 while warming up, |            |              |  (0x0200)      |
 not accepting     |            |              |                |
 jobs)             |            |              |                |
                   |            |              |                |
Warming Up         |running (2) |warmup (5)    |(0x0000)        |
(no binary alerts, |            |              |                |
 accepting jobs)   |            |              |                |
                   |            |              |                |


Critical Errors: the printer can not print

Jam                |down (5)    |other (1)     |Jammed (0x0400) |
                   |            |              |                |
Cover/Door         |down (5)    |other (1)     |Door Open       |
Open (listed       |            |              |  (0x0800       |
in cover table)    |            |              |                |
                   |            |              |                |
Input Tray         |down (5)    |other (1)     |inputTrayMissing|
Missing            |            |              |  (0x0080)      |
                   |            |              |                |
Input Tray         |down (5)    |other (1)     |inputTrayEmpty  |
Empty              |            |              |  (0x0004)      |
                   |            |              |                |
Output Tray        |down (5)    |other (1)     |outputTray      |
Missing            |            |              |Missing (0x0040)|
                   |            |              |                |
Output Tray        |down (5)    |other (1)     |outputFull      |
Full               |            |              |  (0x0008)      |
                   |            |              |                |
Marker Supply      |down (5)    |other (1)     |markerSupply    |
Missing (i.e.,     |            |              |Missing         |
 toner missing,    |            |              |  (0x0020       |
 ink missing)      |            |              |                |
                   |            |              |                |
Marker Supply      |down (5)    |other (1)     |No Toner        |
Empty (i.e.,       |            |              |  (0x1000       |
toner empty,       |            |              |                |
ink missing)       |            |              |                |
                   |            |              |                |


Non-Critical Errors: the printer can still print while condition
exists (the warning may be current while printing)


Turner                 Printer MIB V2                  [Page 159]


INTERNET DRAFT          Printer MIB              January 22, 1999




Input Tray         |warning (3) |idle (3) or   |Low Paper       |
Low                |            |printing (4)  |  (0x8000)      |
                   |            |or warmup (5) |                |
                   |            |              |                |
Output Tray        |warning (3) |idle (3) or   |outputNear      |
Almost Full        |            |printing (4)  |Full (0x0010)   |
                   |            |or warmup (5) |                |
                   |            |              |                |
Marker Supply      |warning (3) |idle (3) or   |Low Toner       |
Almost Empty       |            |printing (4)  | (0x2000)       |
(i.e., toner low,  |            |or warmup (5) |                |
 ink low)          |            |              |                |
                   |            |              |                |
Input Tray         |warning (3) |idle (3) or   |inputTray       |
Missing (when n-1  |            |printing (4)  |Missing         |
trays are missing  |            |or warmup (5) |  (0x0080)      |
with linking)      |            |              |                |
                   |            |              |                |
Input Tray         |warning (3) |idle (3) or   |Low Paper       |
Empty (when n-1    |            |printing (4)  |  (0x8000)      |
trays are empty    |            |or warmup (5) |                |
with linking)      |            |              |                |
                   |            |              |                |
Output Tray        |warning (3) |idle (3) or   |outputTray      |
Missing (when n-1  |            |printing (4)  |Missing         |
trays are missing  |            |or warmup (5) |  (0x0040)      |
with linking)      |            |              |                |
                   |            |              |                |
Output Tray        |warning (3) |idle (3) or   |outputFull      |
Full (when n-1     |            |printing (4)  |  (0x0008)      |
trays are full     |            |or warmup (5) |                |
with linking)      |            |              |                |


                   |                               |
                   |         prtAlertTable         |
                   +-------------------------------+
Printer            |               |               |
State              | prtAlertGroup | prtAlertCode  |
-------------------+---------------+---------------+
Normal or idle     | (no binary    | (no binary    |
(no binary alerts) |  alerts)      |  alerts)      |
                   |               |               |
Printing           | (no binary    | (no binary    |
(no binary alerts) |  alerts)      |  alerts)      |
                   |               |               |
Off-line           | generalPrinter| subunitOffline|


Turner                 Printer MIB V2                  [Page 160]


INTERNET DRAFT          Printer MIB              January 22, 1999



                   | (5)           | (22)          |
                   |               |               |
Standby or Power   | generalPrinter| subunitPower  |
Saver Mode         | (5)           | Saver(23)     |
                   |               |               |
Initial Power Up   |               |               |
(no binary alerts, | (no binary    | (no binary    |
 while warming up, |  alerts)      |  alerts)      |
 not accepting     |               |               |
 jobs)             |               |               |
                   |               |               |
Warming Up         | (no binary    | (no binary    |
(no binary alerts, |  alerts)      |  alerts)      |
 accepting jobs)   |               |               |
                   |               |               |


Critical Errors: the printer can not print

Jam                | appropriate   | jammed(8)     |
                   | group         |               |
                   |               |               |
Cover/Door         | cover(6)      | coverOpened(3)|
Open (listed       |               |               |
in cover table)    |               |               |
                   |               |               |
Input Tray         | input(8)      | subunitMissing|
Missing            |               | (9)           |
                   |               |               |
Input Tray         | input(8)      | subunitEmpty  |
Empty              |               | (13)          |
                   |               |               |
Output Tray        | output(9)     | subunitMissing|
Missing            |               | (9)           |
                   |               |               |
Output Tray        | output(9)     | subunitFull   |
Full               |               | (15)          |
                   |               |               |
Marker Supply      | markerSupplies| subunitMissing|
Missing (i.e.,     | (11)          | (9)           |
 toner missing,    |               |               |
 ink missing)      |               |               |
                   |               |               |
Marker Supply      | markerSupplies| subunitEmpty  |
Empty (i.e.,       | (11)          | (13)          |
 toner empty,      |               |               |
 ink missing)      |               |               |
                   |               |               |


Turner                 Printer MIB V2                  [Page 161]


INTERNET DRAFT          Printer MIB              January 22, 1999





Non-Critical Errors: the printer can still print while condition
exists (the warning may be current while printing)

Input Tray         | input(8)      | subunitAlmost |
Low                |               | Empty(12)     |
                   |               |               |
Output Tray        | output(9)     | subunitAlmost |
Almost Full        |               | Full(14)      |
                   |               |               |
Marker Supply      | markerSupplies| subunitAlmost |
Almost Empty       | (11)          | Empty(12)     |
(i.e., toner low,  |               |               |
 ink low)          |               |               |
                   |               |               |
Input Tray         | input(8)      | subunitMissing|
Missing (when n-1  |               | (9)           |
trays are missing  |               |               |
with linking)      |               |               |
                   |               |               |
Input Tray         | input(8)      | subunitEmpty  |
Empty (when n-1    |               | (13)          |
trays are empty    |               |               |
with linking)      |               |               |
                   |               |               |
Output Tray        | output(9)     | subunitMissing|
Missing (when n-1  |               | (9)           |
trays are missing  |               |               |
with linking)      |               |               |
                   |               |               |
Output Tray        | output(9)     | subunitFull   |
Full (when n-1     |               | (15)          |
trays are full     |               |               |
with linking)      |               |               |















Turner                 Printer MIB V2                  [Page 162]


INTERNET DRAFT          Printer MIB              January 22, 1999



                    | Subunit Status        |
                    | (PrtSubUnitStatusTC)  |
                    +-----------------------+
                    | prtInputStatus        |
                    | (per input tray)      |
                    | prtOutputStatus       |
                    | (per output bin)      |
                    | prtMarkerStatus       |
                    | (per marker)          |
                    | prtMediaPathStatus    |
                    | (per path)            |
Printer             | prtChannelStatus      |
State               | (per channel)         |
--------------------+-----------------------+
Normal or idle      | all groups are:       |
(no binary alerts)  |   Idle (0)            |
                    |                       |
Printing            | Availability may be:  |
(no binary alerts)  |   Idle (0) or         |
                    |   Active (4) or       |
                    |   Busy (6)            |
                    | depending on          |
                    | subsystem state       |
                    |                       |
Off-line            | prtChannelStatus:     |
                    |   Availability=       |
                    |   Unavailable and     |
                    |   OnRequest+          |
                    |   Critical Alerts+    |
                    |   Off-Line            |
                    |   (1+16+32)           |
                    |                       |
Standby or Power    | prtChannelStatus:     |
Saver Mode          |   Availability=       |
                    |   Available and       |
                    |   Standby (2)         |
                    |                       |
Initial Power Up    | all groups are:       |
(no binary alerts,  |   Availability=       |
 while warming up,  |   Unknown+            |
 not accepting jobs)|   Transitioning       |
                    |   (5+64)              |
Warming Up          | all groups are:       |
(no binary alerts,  |   Availability=       |
 accepting jobs)    |   Standby+            |
                    |   Transitioning       |
                    |   (2+64)              |
                    |                       |


Turner                 Printer MIB V2                  [Page 163]


INTERNET DRAFT          Printer MIB              January 22, 1999





Critical Errors: the printer can not print

Jam                 | PrtSubUnitStatusTC    |
                    |   Availability=       |
                    |   Unavailable because |
                    |   broken+Critical     |
                    |   Alerts (3+16)       |
                    |                       |
Cover/Door          | prtCoverStatus:       |
Open (listed        |    coverOpen (3)      |
in cover table)     |                       |
                    |                       |
Input Tray          | prtInputStatus:       |
Missing             |   Availability=       |
                    |   Unavailable because |
                    |   broken+Critical     |
                    |   Alerts (3+16)       |
                    |                       |
Input Tray          | prtInputStatus:       |
Empty               |   Availability=       |
                    |   Unavailable because |
                    |   broken+Critical     |
                    |   Alerts (3+16)       |
                    |                       |
Output Tray         | prtOutputStatus:      |
Missing             |   Availability=       |
                    |   Unavailable because |
                    |   broken+Critical     |
                    |   Alerts (3+16)       |
                    |                       |
Output Tray         | prtOutputStatus:      |
Full                |   Availability=       |
                    |   Unavailable because |
                    |   broken+Critical     |
                    |   Alerts (3+16)       |
                    |                       |
Marker Supply       | prtMarkerStatus:      |
Missing (i.e.,      |   Availability=       |
 toner missing,     |   Unavailable because |
 ink missing)       |   broken+Critical     |
                    |   Alerts (3+16)       |
                    |                       |
Marker Supply       | prtMarkerStatus:      |
Empty (i.e.,        |   Availability=       |
 toner empty,       |   Unavailable because |
 ink missing)       |   broken+Critical     |


Turner                 Printer MIB V2                  [Page 164]


INTERNET DRAFT          Printer MIB              January 22, 1999



                    |   Alerts (3+16)       |
                    |                       |


Non-Critical Errors: the printer can still print while condition
exists (the warning may be current while printing)

Input Tray          | prtInputStatus:       |
Low                 |   Non-Critical        |
                    |   Alerts (8)          |
                    |                       |
Output Tray         | prtOutputStatus:      |
Almost Full         |   Non-Critical        |
                    |   Alerts (8)          |
                    |                       |
Marker Supply       | prtMarkerStatus:      |
Almost Empty        |   Non-Critical        |
(i.e., toner low,   |   Alerts (8)          |
 ink low)           |                       |
                    |                       |
Input Tray          | prtInputStatus:       |
Missing (when n-1   |   Non-Critical        |
trays are missing   |   Alerts (8)          |
with linking)       |                       |
                    |                       |
Input Tray          | prtInputStatus:       |
Empty (when n-1     |   Non-Critical        |
trays are empty     |   Alerts (8)          |
with linking)       |                       |
                    |                       |
Output Tray         | prtOutputStatus:      |
Missing (when n-1   |   Non-Critical        |
trays are missing   |   Alerts (8)          |
with linking)       |                       |
                    |                       |
Output Tray         | prtOutputStatus:      |
Full (when n-1      |   Non-Critical        |
trays are full      |   Alerts (8)          |
with linking)       |                       |

The definition of PrtSubUnitStatusTC specifies that SubUnitStatus
is an integer that is the sum of 5 distinct values/states:
Availability, Critical, Non-Critical, On-line and Transitioning.
Thus when a non-critical alert or alerts are present the values
for Availability, On-Line and Transitioning will be summed with
the Non-Critical Alerts (8) value.




Turner                 Printer MIB V2                  [Page 165]


INTERNET DRAFT          Printer MIB              January 22, 1999



Appendix F - Participants

The following people attended at least one meeting of the Printer
Working Group; many attended most meetings.


     Ron Bergman - Dataproducts
     Luis Cubero - Hewlett-Packard
     Jay Cummings - Novell
     Andy Davidson - Tektronix
     Lee Farrell - Canon
     Joel Gyllenskog - Microworks
     Tom Hastings - Xerox
     Scott Isaacson - Novell
     Binnur Al-Kazily - Hewlett-Packard
     Rick Landau - Digital Equipment Corporation
     David Kellerman - Northlake Software
     Harry Lewis - IBM
     Pete Loya - Hewlett-Packard
     Jay Martin - Underscore
     Bob Pentecost - Hewlett-Packard
     Dave Roach - Unisys
     Stuart Rowley - Kyocera
     Bob Setterbo - Adobe
     Ron Smith - Texas Instruments
     Mike Timperman - Lexmark
     Randy Turner - Sharp Laboratories
     Bill Wagner - Digital Products, Inc.
     Chris Wellens - Interworking Labs
     Craig Whittle - Novell
     Don Wright - Lexmark
     Lloyd Young - Lexmark
     Atsushi Yuki - Kyocera
     Steve Zilles - Adobe

Security Considerations

The Printer MIB specifies a database and not necessarily a
protocol for accessing the database. With regards to the security
of the information within the database, it is anticipated that
the primary vehicle for accessing this data will be through the
use of the Simple Network Protocol (SNMP). SNMP Version 1 has
known security vulnerabilities due to the fact that only a "clear
text" community name is used for accessing MIB objects within a
particular entity. The IETF is pursuing much more robust security
mechanisms with regards to SNMP Version 2, with support
authentication, as well as privacy.



Turner                 Printer MIB V2                  [Page 166]


INTERNET DRAFT          Printer MIB              January 22, 1999



Where the operational capability of the printing device are
especially vulnerable or difficult to administer, certain objects
within the MIB have been tagged as READ-ONLY, preventing
modification. Further, for all READ-WRITE objects within the MIB,
the working group has included specific conformance guidelines
within this document stating that vendors are free to implement
these objects as READ-ONLY. This conformance allowance should
cover cases where specific vendor vulnerabilities may differ from
product to product. (See conformance section with regards to MIN-
ACCESS clauses).

It is the intention of the working group to delegate true
security mechanisms for accessing these MIB objects to the
overall SNMP Version 2 working group, but not to preclude
individual implementations from generating proprietary or
additional security mechanisms for SNMP Version 1.0 environments.

Copyright

"Copyright (C) The Internet Society 1995, 1997. All Rights
Reserved.

This document and translations of it may be copied and furnished
to others, and derivative works that comment on or otherwise
explain it or assist in its implementation may be prepared,
copied, published and distributed, in whole or in part, without
restriction of any kind, provided that the above copyright notice
and this paragraph are included on all such copies and derivative
works.  However, this document itself may not be modified in any
way, such as by removing the copyright notice or references to
the Internet Society or other Internet organizations, except as
needed for the purpose of developing Internet standards in which
case the procedures for copyrights defined in the Internet
Standards process must be followed, or as required to translate
it into languages other than English.

The limited permissions granted above are perpetual and will not
be revoked by the Internet Society or its successors or assigns.

This document and the information contained herein is provided on
an "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET
ENGINEERING TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE
OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE."




Turner                 Printer MIB V2                  [Page 167]


INTERNET DRAFT          Printer MIB              January 22, 1999



References

[NVT ASCII]    J. Postel, J. Reynolds, "TELENET PROTOCOL
               SPECIFICATION", RFC 854, May 1983.

[US-ASCII]     Coded Character Set - 7-bit American Standard Code
               for Information Interchange, ANSI X3.4-1986.

Authors' Addresses

   Randy Turner
   Sharp Laboratories of America

   Phone (360) 817-8456
   Email: rturner@sharplabs.com


With significant contributions from the following individuals

   Ronald L. Smith
   Texas Instruments
   Phone: (817) 774-6151
   EMail: rlsmith@nb.ppd.ti.com

   F.D. Wright
   Lexmark International
   Phone: (606) 232-4808
   EMail: don@lexmark.com

   Thomas N. Hastings
   Xerox Corporation
   Phone:  (310) 333-6413
   EMail:  hastings@cp10.es.xerox.com

   Stephen N. Zilles
   Adobe Systems, Inc.
   Phone: (415) 962-4766
   EMail: szilles@mv.us.adobe.com

   Joel Gyllenskog
   Microworks, Inc.
   Phone: (208) 375-1234
   EMail: joelgyllen@aol.com

   Scott Isaacson
   Novell
   Phone: (801) 861-7366
   Email: Scott-Isaacson@novell.com


Turner                 Printer MIB V2                  [Page 168]


INTERNET DRAFT          Printer MIB              January 22, 1999




   Binnur Al-Kazily
   Hewlett-Packard, Inc.

   David Kellerman
   Northlake Software
   Phone: (503) 228-3383
   Email: kellerman@nls.com

   Matt King
   Lexmark International
   Phone: (606) 232-6907
   Email: emking@lexmark.com

   Harry Lewis
   IBM
   Phone: (303) 924-5337
   Email: harryl@us.ibm.com

   Jay Martin
   Underscore
   Phone: (603) 889-7000
   Email: jkm@underscore.com

   Mike McKay
   Novell, Inc.

   Bob Pentecost
   Hewlett-Packard
   Phone: (208) 396-3312
   Email: bpenteco@boi.hp.com

   William Wagner
   Digital Products
   Email: bwagner@digprod.com

   Chris Wellens
   Interworking Labs
   Phone: (408) 685-3190
   Email: chrisw@iwl.com

   Lloyd Young
   Lexmark International
   Phone: (606) 232-5150
   Email: lpyoung@lexmark.com

   Chuck Adams
   Tektronix


Turner                 Printer MIB V2                  [Page 169]


INTERNET DRAFT          Printer MIB              January 22, 1999



   Phone: (502) 685-2589
   Email: adamsc@pogo.wv.tek.com
















































Turner                 Printer MIB V2                  [Page 170]