Benchmarking Working Group M. Konstantynowicz, Ed.
Internet-Draft P. Mikus, Ed.
Intended status: Informational Cisco Systems
Expires: September 12, 2019 March 11, 2019
NFV Service Density Benchmarking
draft-mkonstan-nf-service-density-00
Abstract
Network Function Virtualization (NFV) system designers and operators
continuously grapple with the problem of qualifying performance of
network services realised with software Network Functions (NF)
running on Commercial-Off-The-Shelf (COTS) servers. One of the main
challenges is getting repeatable and portable benchmarking results
and using them to derive deterministic operating range that is
production deployment worthy.
This document specifies benchmarking methodology for NFV services
that aims to address this problem space. It defines a way for
measuring performance of multiple NFV service instances, each
composed of multiple software NFs, and running them at a varied
service "packing" density on a single server.
The aim is to discover deterministic usage range of NFV system. In
addition specified methodology can be used to compare and contrast
different NFV virtualization technologies.
Status of This Memo
This Internet-Draft is submitted in full conformance with the
provisions of BCP 78 and BCP 79.
Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF). Note that other groups may also distribute
working documents as Internet-Drafts. The list of current Internet-
Drafts is at https://datatracker.ietf.org/drafts/current/.
Internet-Drafts are draft documents valid for a maximum of six months
and may be updated, replaced, or obsoleted by other documents at any
time. It is inappropriate to use Internet-Drafts as reference
material or to cite them other than as "work in progress."
This Internet-Draft will expire on September 12, 2019.
Konstantynowicz & MikusExpires September 12, 2019 [Page 1]
Internet-Draft NFV Service Density Benchmarking March 2019
Copyright Notice
Copyright (c) 2019 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents
(https://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
the Trust Legal Provisions and are provided without warranty as
described in the Simplified BSD License.
Table of Contents
1. Terminology . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. Motivation . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1. Problem Description . . . . . . . . . . . . . . . . . . . 3
2.2. Proposed Solution . . . . . . . . . . . . . . . . . . . . 4
3. NFV Service . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.1. Topology . . . . . . . . . . . . . . . . . . . . . . . . 5
3.2. Configuration . . . . . . . . . . . . . . . . . . . . . . 7
3.3. Packet Path(s) . . . . . . . . . . . . . . . . . . . . . 8
4. Virtualization Technology . . . . . . . . . . . . . . . . . . 10
5. Host Networking . . . . . . . . . . . . . . . . . . . . . . . 11
6. NFV Service Density Matrix . . . . . . . . . . . . . . . . . 12
7. Compute Resource Allocation . . . . . . . . . . . . . . . . . 13
8. NFV Service Density Benchmarks . . . . . . . . . . . . . . . 17
8.1. Test Methodology - MRR Throughput . . . . . . . . . . . . 17
8.2. VNF Service Chain . . . . . . . . . . . . . . . . . . . . 18
8.3. CNF Service Chain . . . . . . . . . . . . . . . . . . . . 18
8.4. CNF Service Pipeline . . . . . . . . . . . . . . . . . . 19
8.5. Sample Results: FD.io CSIT . . . . . . . . . . . . . . . 20
8.6. Sample Results: CNCF/CNFs . . . . . . . . . . . . . . . . 21
9. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 23
10. Security Considerations . . . . . . . . . . . . . . . . . . . 23
11. Acknowledgements . . . . . . . . . . . . . . . . . . . . . . 23
12. References . . . . . . . . . . . . . . . . . . . . . . . . . 23
12.1. Normative References . . . . . . . . . . . . . . . . . . 23
12.2. Informative References . . . . . . . . . . . . . . . . . 23
Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . . 25
Konstantynowicz & MikusExpires September 12, 2019 [Page 2]
Internet-Draft NFV Service Density Benchmarking March 2019
1. Terminology
o NFV - Network Function Virtualization, a general industry term
describing network functionality implemented in software.
o NFV service - a software based network service realized by a
topology of interconnected constituent software network function
applications.
o NFV service instance - a single instantiation of NFV service.
o Data-plane optimized software - any software with dedicated
threads handling data-plane packet processing e.g. FD.io VPP
(Vector Packet Processor), OVS-DPDK.
2. Motivation
2.1. Problem Description
Network Function Virtualization (NFV) system designers and operators
continuously grapple with the problem of qualifying performance of
network services realised with software Network Functions (NF)
running on Commercial-Off-The-Shelf (COTS) servers. One of the main
challenges is getting repeatable and portable benchmarking results
and using them to derive deterministic operating range that is
production deployment worthy.
Lack of well defined and standardised NFV centric performance
methodology and metrics makes it hard to address fundamental
questions that underpin NFV production deployments:
1. What NFV service and how many instances can run on a single
compute node?
2. How to choose the best compute resource allocation scheme to
maximise service yield per node?
3. How do different NF applications compare from the service density
perspective?
4. How do the virtualisation technologies compare e.g. Virtual
Machines, Containers?
Getting answers to these points should allow designers to make a data
based decision about the NFV technology and service design best
suited to meet requirements of their use cases. Equally, obtaining
the benchmarking data underpinning those answers should make it
Konstantynowicz & MikusExpires September 12, 2019 [Page 3]
Internet-Draft NFV Service Density Benchmarking March 2019
easier for operators to work out expected deterministic operating
range of chosen design.
2.2. Proposed Solution
The primary goal of the proposed benchmarking methodology is to focus
on NFV technologies used to construct NFV services. More
specifically to i) measure packet data-plane performance of multiple
NFV service instances while running them at varied service "packing"
densities on a single server and ii) quantify the impact of using
multiple NFs to construct each NFV service instance and introducing
multiple packet processing hops and links on each packet path.
The overarching aim is to discover a set of deterministic usage
ranges that are of interest to NFV system designers and operators.
In addition, specified methodology can be used to compare and
contrast different NFV virtualisation technologies.
In order to ensure wide applicability of the benchmarking
methodology, the approach is to separate NFV service packet
processing from the shared virtualisation infrastructure by
decomposing the software technology stack into three building blocks:
+-------------------------------+
| NFV Service |
+-------------------------------+
| Virtualization Technology |
+-------------------------------+
| Host Networking |
+-------------------------------+
Figure 1. NFV software technology stack.
Proposed methodology is complementary to existing NFV benchmarking
industry efforts focusing on vSwitch benchmarking [RFC8204], [TST009]
and extends the benchmarking scope to NFV services.
This document does not describe a complete benchmarking methodology,
instead it is focusing on system under test configuration part. Each
of the compute node configurations identified by (RowIndex,
ColumnIndex) is to be evaluated for NFV service data-plane
performance using existing and/or emerging network benchmarking
standards. This may include methodologies specified in [RFC2544],
[TST009], [draft-vpolak-mkonstan-bmwg-mlrsearch] and/or
[draft-vpolak-bmwg-plrsearch].
Konstantynowicz & MikusExpires September 12, 2019 [Page 4]
Internet-Draft NFV Service Density Benchmarking March 2019
3. NFV Service
It is assumed that each NFV service instance is built of one or more
constituent NFs and is described by: topology, configuration and
resulting packet path(s).
Each set of NFs forms an independent NFV service instance, with
multiple sets present in the host.
3.1. Topology
NFV topology describes the number of network functions per service
instance, and their inter-connections over packet interfaces. It
includes all point-to-point virtual packet links within the compute
node, Layer-2 Ethernet or Layer-3 IP, including the ones to host
networking data-plane.
Theoretically, a large set of possible NFV topologies can be realised
using software virtualisation topologies, e.g. ring, partial -/full-
mesh, star, line, tree, ladder. In practice however, only a few
topologies are in the actual use as NFV services mostly perform
either bumps-in-a-wire packet operations (e.g. security filtering/
inspection, monitoring/telemetry) and/or inter-site forwarding
decisions (e.g. routing, switching).
Two main NFV topologies have been identified so far for NFV service
density benchmarking:
1. Chain topology: a set of NFs connect to host data-plane with
minimum of two virtual interfaces each, enabling host data-plane
to facilitate NF to NF service chain forwarding and provide
connectivity with external network.
2. Pipeline topology: a set of NFs connect to each other in a line
fashion with edge NFs homed to host data-plane. Host data-plane
provides connectivity with external network.
Both topologies are shown in figures below.
NF chain topology:
Konstantynowicz & MikusExpires September 12, 2019 [Page 5]
Internet-Draft NFV Service Density Benchmarking March 2019
+-----------------------------------------------------------+
| Host Compute Node |
| |
| +--------+ +--------+ +--------+ |
| | S1NF1 | | S1NF2 | | S1NFn | |
| | | | | .... | | Service1 |
| | | | | | | |
| +-+----+-+ +-+----+-+ + + +-+----+-+ |
| | | | | | | | | Virtual |
| | |<-CS->| |<-CS->| |<-CS->| | Interfaces |
| +-+----+------+----+------+----+------+----+-+ |
| | | CS: Chain |
| | | Segment |
| | Host Data-Plane | |
| +-+--+----------------------------------+--+-+ |
| | | | | |
+-----------------------------------------------------------+
| | | | Physical
| | | | Interfaces
+---+--+----------------------------------+--+--------------+
| |
| Traffic Generator |
| |
+-----------------------------------------------------------+
Figure 2. NF chain topology forming a service instance.
NF pipeline topology:
Konstantynowicz & MikusExpires September 12, 2019 [Page 6]
Internet-Draft NFV Service Density Benchmarking March 2019
+-----------------------------------------------------------+
| Host Compute Node |
| |
| +--------+ +--------+ +--------+ |
| | S1NF1 | | S1NF2 | | S1NFn | |
| | +--+ +--+ .... +--+ | Service1 |
| | | | | | | |
| +-+------+ +--------+ +------+-+ |
| | | Virtual |
| |<-Pipeline Edge Pipeline Edge->| Interfaces |
| +-+----------------------------------------+-+ |
| | | |
| | | |
| | Host Data-Plane | |
| +-+--+----------------------------------+--+-+ |
| | | | | |
+-----------------------------------------------------------+
| | | | Physical
| | | | Interfaces
+---+--+----------------------------------+--+--------------+
| |
| Traffic Generator |
| |
+-----------------------------------------------------------+
Figure 3. NF pipeline topology forming a service instance.
3.2. Configuration
NFV configuration includes all packet processing functions in NFs
including Layer-2, Layer-3 and/or Layer-4-to-7 processing as
appropriate to specific NF and NFV service design. L2 sub- interface
encapsulations (e.g. 802.1q, 802.1ad) and IP overlay encapsulation
(e.g. VXLAN, IPSec, GRE) may be represented here too as appropriate,
although in most cases they are used as external encapsulation and
handled by host networking data-plane.
NFV configuration determines logical network connectivity that is
Layer-2 and/or IPv4/IPv6 switching/routing modes, as well as NFV
service specific aspects. In the context of NFV density benchmarking
methodology the initial focus is on the former.
Building on the two identified NFV topologies, two common NFV
configurations are considered:
1. Chain configuration:
* Relies on chain topology to form NFV service chains.
Konstantynowicz & MikusExpires September 12, 2019 [Page 7]
Internet-Draft NFV Service Density Benchmarking March 2019
* NF packet forwarding designs:
+ IPv4/IPv6 routing.
* Requirements for host data-plane:
+ L2 switching with L2 forwarding context per each NF chain
segment, or
+ IPv4/IPv6 routing with IP forwarding context per each NF
chain segment or per NF chain.
2. Pipeline configuration:
* Relies on pipeline topology to form NFV service pipelines.
* Packet forwarding designs:
+ IPv4/IPv6 routing.
* Requirements for host data-plane:
+ L2 switching with L2 forwarding context per each NF
pipeline edge link, or
+ IPv4/IPv6 routing with IP forwarding context per each NF
pipeline edge link or per NF pipeline.
3.3. Packet Path(s)
NFV packet path(s) describe the actual packet forwarding path(s) used
for benchmarking, resulting from NFV topology and configuration.
They are aimed to resemble true packet forwarding actions during the
NFV service lifecycle.
Based on the specified NFV topologies and configurations two NFV
packet paths are taken for benchmarking:
1. Snake packet path
* Requires chain topology and configuration.
* Packets enter the NFV chain through one edge NF and progress
to the other edge NF of the chain.
* Within the chain, packets follow a zigzagging "snake" path
entering and leaving host data-plane as they progress through
the NF chain.
Konstantynowicz & MikusExpires September 12, 2019 [Page 8]
Internet-Draft NFV Service Density Benchmarking March 2019
* Host data-plane is involved in packet forwarding operations
between NIC interfaces and edge NFs, as well as between NFs in
the chain.
2. Pipeline packet path
* Requires pipeline topology and configuration.
* Packets enter the NFV chain through one edge NF and progress
to the other edge NF of the pipeline.
* Within the chain, packets follow a straight path entering and
leaving subsequent NFs as they progress through the NF
pipeline.
* Host data-plane is involved in packet forwarding operations
between NIC interfaces and edge NFs only.
Both packet paths are shown in figures below.
Snake packet path:
+-----------------------------------------------------------+
| Host Compute Node |
| |
| +--------+ +--------+ +--------+ |
| | S1NF1 | | S1NF2 | | S1NFn | |
| | | | | .... | | Service1 |
| | XXXX | | XXXX | | XXXX | |
| +-+X--X+-+ +-+X--X+-+ +X X+ +-+X--X+-+ |
| |X X| |X X| |X X| |X X| Virtual |
| |X X| |X X| |X X| |X X| Interfaces |
| +-+X--X+------+X--X+------+X--X+------+X--X+-+ |
| | X XXXXXXXXXX XXXXXXXXXX XXXXXXXXXX X | |
| | X X | |
| | X Host Data-Plane X | |
| +-+X-+----------------------------------+-X+-+ |
| |X | | X| |
+----X--------------------------------------X---------------+
|X | | X| Physical
|X | | X| Interfaces
+---+X-+----------------------------------+-X+--------------+
| |
| Traffic Generator |
| |
+-----------------------------------------------------------+
Figure 4. Snake packet path thru NF chain topology.
Konstantynowicz & MikusExpires September 12, 2019 [Page 9]
Internet-Draft NFV Service Density Benchmarking March 2019
Pipeline packet path:
+-----------------------------------------------------------+
| Host Compute Node |
| |
| +--------+ +--------+ +--------+ |
| | S1NF1 | | S1NF2 | | S1NFn | |
| | +--+ +--+ .... +--+ | Service1 |
| | XXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXX | |
| +--X-----+ +--------+ +-----X--+ |
| |X X| Virtual |
| |X X| Interfaces |
| +-+X--------------------------------------X+-+ |
| | X X | |
| | X X | |
| | X Host Data-Plane X | |
| +-+X-+----------------------------------+-X+-+ |
| |X | | X| |
+----X--------------------------------------X---------------+
|X | | X| Physical
|X | | X| Interfaces
+---+X-+----------------------------------+-X+--------------+
| |
| Traffic Generator |
| |
+-----------------------------------------------------------+
Figure 5. Pipeline packet path thru NF pipeline topology.
In all cases packets enter NFV system via shared physical NIC
interfaces controlled by shared host data-plane, are then associated
with specific NFV service (based on service discriminator) and
subsequently are cross- connected/switched/routed by host data-plane
to and through NF topologies per one of above listed schemes.
4. Virtualization Technology
NFV services are built of composite isolated NFs, with virtualisation
technology providing the workload isolation. Following
virtualisation technology types are considered for NFV service
density benchmarking:
1. Virtual Machines (VMs)
* Relying on host hypervisor technology e.g. KVM, ESXi, Xen.
* NFs running in VMs are referred to as VNFs.
Konstantynowicz & MikusExpires September 12, 2019 [Page 10]
Internet-Draft NFV Service Density Benchmarking March 2019
2. Containers
* Relying on Linux container technology e.g. LXC, Docker.
* NFs running in Containers are referred to as CNFs.
Different virtual interface types are available to VNFs and CNFs:
1. VNF
* virtio-vhostuser: fully user-mode based virtual interface.
* virtio-vhostnet: involves kernel-mode based backend.
2. CNF
* memif: fully user-mode based virtual interface.
* af_packet: involves kernel-mode based backend.
* (add more common ones)
5. Host Networking
Host networking data-plane is the central shared resource that
underpins creation of NFV services. It handles all of the
connectivity to external physical network devices through physical
network connections using NICs, through which the benchmarking is
done.
Assuming that NIC interface resources are shared, here is the list of
widely available host data-plane options for providing packet
connectivity to/from NICs and constructing NFV chain and pipeline
topologies and configurations:
o Linux Kernel-Mode Networking.
o Linux User-Mode vSwitch.
o Virtual Machine vSwitch.
o Linux Container vSwitch.
o SRIOV NIC Virtual Function - note: restricted support for chain
and pipeline topologies, as it requires hair-pinning through the
NIC and oftentimes also through external physical switch.
Konstantynowicz & MikusExpires September 12, 2019 [Page 11]
Internet-Draft NFV Service Density Benchmarking March 2019
Analysing properties of each of these options and their Pros/Cons for
specified NFV topologies and configurations is outside the scope of
this document.
From all listed options, performance optimised Linux user-mode
vswitch deserves special attention. Linux user-mode switch decouples
NFV service from the underlying NIC hardware, offers rich multi-
tenant functionality and most flexibility for supporting NFV
services. But in the same time it is consuming compute resources and
is harder to benchmark in NFV service density scenarios.
Following sections focus on using Linux user-mode vSwitch, focusing
on its performance benchmarking at increasing levels of NFV service
density.
6. NFV Service Density Matrix
In order to evaluate performance of multiple NFV services running on
a compute node, NFV service instances are benchmarked at increasing
density, allowing to construct an NFV Service Density Matrix.
Table below shows an example of such a matrix, capturing number of
NFV service instances (row indices), number of NFs per service
instance (column indices) and resulting total number of NFs (values).
NFV Service Density - NF Count View
SVC 001 002 004 006 008 00N
001 1 2 4 6 8 1*N
002 2 4 8 12 16 2*N
004 4 8 16 24 32 4*N
006 6 12 24 36 48 6*N
008 8 16 32 48 64 8*N
00M M*1 M*2 M*4 M*6 M*8 M*N
RowIndex: Number of NFV Service Instances, 1..M.
ColumnIndex: Number of NFs per NFV Service Instance, 1..N.
Value: Total number of NFs running in the system.
In order to deliver good and repeatable network data-plane
performance, NFs and host data-plane software require direct access
to critical compute resources. Due to a shared nature of all
resources on a compute node, a clearly defined resource allocation
scheme is defined in the next section to address this.
In each tested configuration host data-plane is a gateway between the
external network and the internal NFV network topologies. Offered
packet load is generated and received by an external traffic
generator per usual benchmarking practice.
Konstantynowicz & MikusExpires September 12, 2019 [Page 12]
Internet-Draft NFV Service Density Benchmarking March 2019
It is proposed that initial benchmarks are done with the offered
packet load distributed equally across all configured NFV service
instances. This could be followed by various per NFV service
instance load ratios mimicking expected production deployment
scenario(s).
Following sections specify compute resource allocation, followed by
examples of applying NFV service density methodology to VNF and CNF
benchmarking use cases.
7. Compute Resource Allocation
Performance optimized NF and host data-plane software threads require
timely execution of packet processing instructions and are very
sensitive to any interruptions (or stalls) to this execution e.g. cpu
core context switching, or cpu jitter. To that end, NFV service
density methodology treats controlled mapping ratios of data plane
software threads to physical processor cores with directly allocated
cache hierarchies as the first order requirement.
Other compute resources including memory bandwidth and PCIe bandwidth
have lesser impact and as such are subject for further study. For
more detail and deep-dive analysis of software data plane performance
and impact on different shared compute resources is available in
[BSDP].
It is assumed that NFs as well as host data-plane (e.g. vswitch) are
performance optimized, with their tasks executed in two types of
software threads:
o data-plane - handling data-plane packet processing and forwarding,
time critical, requires dedicated cores. To scale data-plane
performance, most NF apps use multiple data-plane threads and rely
on NIC RSS (Receive Side Scaling), virtual interface multi-queue
and/or integrated software hashing to distribute packets across
the data threads.
o main-control - handling application management, statistics and
control-planes, less time critical, allows for core sharing. For
most NF apps this is a single main thread, but often statistics
(counters) and various control protocol software are run in
separate threads.
Core mapping scheme described below allocates cores for all threads
of specified type belonging to each NF app instance, and separately
lists number of threads to a number of logical/physical core mappings
for processor configurations with enabled/disabled Symmetric Multi-
Threading (SMT) (e.g. AMD SMT, Intel Hyper-Threading).
Konstantynowicz & MikusExpires September 12, 2019 [Page 13]
Internet-Draft NFV Service Density Benchmarking March 2019
If NFV service density benchmarking is run on server nodes with
Symmetric Multi-Threading (SMT) (e.g. AMD SMT, Intel Hyper-
Threading) for higher performance and efficiency, logical cores
allocated to data- plane threads should be allocated as pairs of
sibling logical cores corresponding to the hyper-threads running on
the same physical core.
Separate core ratios are defined for mapping threads of vSwitch and
NFs. In order to get consistent benchmarking results, the mapping
ratios are enforced using Linux core pinning.
Konstantynowicz & MikusExpires September 12, 2019 [Page 14]
Internet-Draft NFV Service Density Benchmarking March 2019
+-------------+--------+----------+----------------+----------------+
| application | thread | app:core | threads/pcores | threads/lcores |
| | type | ratio | (SMT disabled) | map (SMT |
| | | | | enabled) |
+-------------+--------+----------+----------------+----------------+
| vSwitch-1c | data | 1:1 | 1DT/1PC | 2DT/2LC |
| | | | | |
| | main | 1:S2 | 1MT/S2PC | 1MT/1LC |
| | | | | |
| | | | | |
| | | | | |
| vSwitch-2c | data | 1:2 | 2DT/2PC | 4DT/4LC |
| | | | | |
| | main | 1:S2 | 1MT/S2PC | 1MT/1LC |
| | | | | |
| | | | | |
| | | | | |
| vSwitch-4c | data | 1:4 | 4DT/4PC | 8DT/8LC |
| | | | | |
| | main | 1:S2 | 1MT/S2PC | 1MT/1LC |
| | | | | |
| | | | | |
| | | | | |
| NF-0.5c | data | 1:S2 | 1DT/S2PC | 1DT/1LC |
| | | | | |
| | main | 1:S2 | 1MT/S2PC | 1MT/1LC |
| | | | | |
| | | | | |
| | | | | |
| NF-1c | data | 1:1 | 1DT/1PC | 2DT/2LC |
| | | | | |
| | main | 1:S2 | 1MT/S2PC | 1MT/1LC |
| | | | | |
| | | | | |
| | | | | |
| NF-2c | data | 1:2 | 2DT/2PC | 4DT/4LC |
| | | | | |
| | main | 1:S2 | 1MT/S2PC | 1MT/1LC |
+-------------+--------+----------+----------------+----------------+
o Legend to table
* Header row
+ application - network application with optimized data-plane,
a vSwitch or Network Function (NF) application.
Konstantynowicz & MikusExpires September 12, 2019 [Page 15]
Internet-Draft NFV Service Density Benchmarking March 2019
+ thread type - either "data", short for data-plane; or
"main", short for all main-control threads.
+ app:core ratio - ratio of per application instance threads
of specific thread type to physical cores.
+ threads/pcores (SMT disabled) - number of threads of
specific type (DT for data-plane thread, MT for main thread)
running on a number of physical cores, with SMT disabled.
+ threads/lcores map (SMT enabled) - number of threads of
specific type (DT, MT) running on a number of logical cores,
with SMT enabled. Two logical cores per one physical core.
* Content rows
+ vSwitch-(1c|2c|4c) - vSwitch with 1 physical core (or 2, or
4) allocated to its data-plane software worker threads.
+ NF-(0.5c|1c|2c) - NF application with half of a physical
core (or 1, or 2) allocated to its data-plane software
worker threads.
+ Sn - shared core, sharing ratio of (n).
+ DT - data-plane thread.
+ MT - main-control thread.
+ PC - physical core, with SMT/HT enabled has many (mostly 2
today) logical cores associated with it.
+ LC - logical core, if more than one lc get allocated in sets
of two sibling logical cores running on the same physical
core.
+ SnPC - shared physical core, sharing ratio of (n).
+ SnLC - shared logical core, sharing ratio of (n).
Maximum benchmarked NFV service densities are limited by a number of
physical cores on a compute node.
A sample physical core usage view is shown in the matrix below.
Konstantynowicz & MikusExpires September 12, 2019 [Page 16]
Internet-Draft NFV Service Density Benchmarking March 2019
NFV Service Density - Core Usage View
vSwitch-1c, NF-1c
SVC 001 002 004 006 008 010
001 2 3 6 9 12 15
002 3 6 12 18 24 30
004 6 12 24 36 48 60
006 9 18 36 54 72 90
008 12 24 48 72 96 120
010 15 30 60 90 120 150
RowIndex: Number of NFV Service Instances, 1..10.
ColumnIndex: Number of NFs per NFV Service Instance, 1..10.
Value: Total number of physical processor cores used for NFs.
8. NFV Service Density Benchmarks
To illustrate defined NFV service density applicability, following
sections describe three sets of NFV service topologies and
configurations that have been benchmarked in open-source: i) in
[LFN-FDio-CSIT], a continuous testing and data-plane benchmarking
project, and ii) as part of CNCF CNF Testbed initiative
[CNCF-CNF-Testbed].
In both cases each NFV service instance definition is based on the
same set of NF applications, and varies only by network addressing
configuration to emulate multi-tenant operating environment.
8.1. Test Methodology - MRR Throughput
Initial NFV density throughput benchmarks have been performed using
Maximum Receive Rate (MRR) test methodology defined and used in FD.io
CSIT.
MRR tests measure the packet forwarding rate under the maximum load
offered by traffic generator over a set trial duration, regardless of
packet loss. Maximum load for specified Ethernet frame size is set
to the bi-directional link rate (2x 10GbE in referred results).
Tests were conducted with two traffic profiles: i) continuous stream
of 64B frames, ii) continuous stream of IMIX sequence of (7x 64B, 4x
570B, 1x 1518B), all sizes are L2 untagged Ethernet.
NFV service topologies tested include: VNF service chains, CNF
service chains and CNF service pipelines.
Konstantynowicz & MikusExpires September 12, 2019 [Page 17]
Internet-Draft NFV Service Density Benchmarking March 2019
8.2. VNF Service Chain
VNF Service Chain (VSC) topology is tested with KVM hypervisor
(Ubuntu 18.04-LTS), with NFV service instances consisting of NFs
running in VMs (VNFs). Host data-plane is provided by FD.io VPP
vswitch. Virtual interfaces are virtio-vhostuser. Snake forwarding
packet path is tested using [TRex] traffic generator, see figure.
+-----------------------------------------------------------+
| Host Compute Node |
| |
| +--------+ +--------+ +--------+ |
| | S1VNF1 | | S1VNF2 | | S1VNFn | |
| | | | | .... | | Service1 |
| | XXXX | | XXXX | | XXXX | |
| +-+X--X+-+ +-+X--X+-+ +-+X--X+-+ |
| |X X| |X X| |X X| Virtual |
| |X X| |X X| |X X| |X X| Interfaces |
| +-+X--X+------+X--X+------+X--X+------+X--X+-+ |
| | X XXXXXXXXXX XXXXXXXXXX XXXXXXXXXX X | |
| | X X | |
| | X FD.io VPP vSwitch X | |
| +-+X-+----------------------------------+-X+-+ |
| |X | | X| |
+----X--------------------------------------X---------------+
|X | | X| Physical
|X | | X| Interfaces
+---+X-+----------------------------------+-X+--------------+
| |
| Traffic Generator (TRex) |
| |
+-----------------------------------------------------------+
Figure 6. VNF service chain test setup.
8.3. CNF Service Chain
CNF Service Chain (CSC) topology is tested with Docker containers
(Ubuntu 18.04-LTS), with NFV service instances consisting of NFs
running in Containers (CNFs). Host data-plane is provided by FD.io
VPP vswitch. Virtual interfaces are memif. Snake forwarding packet
path is tested using [TRex] traffic generator, see figure.
Konstantynowicz & MikusExpires September 12, 2019 [Page 18]
Internet-Draft NFV Service Density Benchmarking March 2019
+-----------------------------------------------------------+
| Host Compute Node |
| |
| +--------+ +--------+ +--------+ |
| | S1CNF1 | | S1CNF2 | | S1CNFn | |
| | | | | .... | | Service1 |
| | XXXX | | XXXX | | XXXX | |
| +-+X--X+-+ +-+X--X+-+ +-+X--X+-+ |
| |X X| |X X| |X X| Virtual |
| |X X| |X X| |X X| |X X| Interfaces |
| +-+X--X+------+X--X+------+X--X+------+X--X+-+ |
| | X XXXXXXXXXX XXXXXXXXXX XXXXXXXXXX X | |
| | X X | |
| | X FD.io VPP vSwitch X | |
| +-+X-+----------------------------------+-X+-+ |
| |X | | X| |
+----X--------------------------------------X---------------+
|X | | X| Physical
|X | | X| Interfaces
+---+X-+----------------------------------+-X+--------------+
| |
| Traffic Generator (TRex) |
| |
+-----------------------------------------------------------+
Figure 7. CNF service chain test setup.
8.4. CNF Service Pipeline
CNF Service Pipeline (CSP) topology is tested with Docker containers
(Ubuntu 18.04-LTS), with NFV service instances consisting of NFs
running in Containers (CNFs). Host data-plane is provided by FD.io
VPP vswitch. Virtual interfaces are memif. Pipeline forwarding
packet path is tested using [TRex] traffic generator, see figure.
Konstantynowicz & MikusExpires September 12, 2019 [Page 19]
Internet-Draft NFV Service Density Benchmarking March 2019
+-----------------------------------------------------------+
| Host Compute Node |
| |
| +--------+ +--------+ +--------+ |
| | S1NF1 | | S1NF2 | | S1NFn | |
| | +--+ +--+ .... +--+ | Service1 |
| | XXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXX | |
| +--X-----+ +--------+ +-----X--+ |
| |X X| Virtual |
| |X X| Interfaces |
| +-+X--------------------------------------X+-+ |
| | X X | |
| | X X | |
| | X FD.io VPP vSwitch X | |
| +-+X-+----------------------------------+-X+-+ |
| |X | | X| |
+----X--------------------------------------X---------------+
|X | | X| Physical
|X | | X| Interfaces
+---+X-+----------------------------------+-X+--------------+
| |
| Traffic Generator (TRex) |
| |
+-----------------------------------------------------------+
Figure 8. CNF service chain test setup.
8.5. Sample Results: FD.io CSIT
FD.io CSIT project introduced NFV density benchmarking in release
CSIT-1901 and published results for the following NFV service
topologies and configurations:
1. VNF Service Chains
* VNF: DPDK-L3FWD v18.10
+ IPv4 forwarding
+ NF-1c
* vSwitch: VPP v19.01-release
+ L2 MAC switching
+ vSwitch-1c, vSwitch-2c
* frame sizes: 64B, IMIX
Konstantynowicz & MikusExpires September 12, 2019 [Page 20]
Internet-Draft NFV Service Density Benchmarking March 2019
2. CNF Service Chains
* CNF: VPP v19.01-release
+ IPv4 routing
+ NF-1c
* vSwitch: VPP v19.01-release
+ L2 MAC switching
+ vSwitch-1c, vSwitch-2c
* frame sizes: 64B, IMIX
3. CNF Service Pipelines
* CNF: VPP v19.01-release
+ IPv4 routing
+ NF-1c
* vSwitch: VPP v19.01-release
+ L2 MAC switching
+ vSwitch-1c, vSwitch-2c
* frame sizes: 64B, IMIX
More information is available in FD.io CSIT-1901 report, with
specific references listed below:
o Testbed: [CSIT-1901-testbed-2n-skx]
o Test environment: [CSIT-1901-test-enviroment]
o Methodology: [CSIT-1901-nfv-density-methodology]
o Results: [CSIT-1901-nfv-density-results]
8.6. Sample Results: CNCF/CNFs
CNCF CI team introduced a CNF testbed initiative focusing on
benchmaring NFV density with open-source network applications running
Konstantynowicz & MikusExpires September 12, 2019 [Page 21]
Internet-Draft NFV Service Density Benchmarking March 2019
as VNFs and CNFs. Following NFV service topologies and
configurations have been tested to date:
1. VNF Service Chains
* VNF: VPP v18.10-release
+ IPv4 routing
+ NF-1c
* vSwitch: VPP v18.10-release
+ L2 MAC switching
+ vSwitch-1c, vSwitch-2c
* frame sizes: 64B, IMIX
2. CNF Service Chains
* CNF: VPP v18.10-release
+ IPv4 routing
+ NF-1c
* vSwitch: VPP v18.10-release
+ L2 MAC switching
+ vSwitch-1c, vSwitch-2c
* frame sizes: 64B, IMIX
3. CNF Service Pipelines
* CNF: VPP v18.10-release
+ IPv4 routing
+ NF-1c
* vSwitch: VPP v18.10-release
+ L2 MAC switching
+ vSwitch-1c, vSwitch-2c
Konstantynowicz & MikusExpires September 12, 2019 [Page 22]
Internet-Draft NFV Service Density Benchmarking March 2019
* frame sizes: 64B, IMIX
More information is available in CNCF CNF Testbed github, with
summary test results presented in summary markdown file, references
listed below:
o Results: [CNCF-CNF-Testbed-Results]
9. IANA Considerations
No requests of IANA
10. Security Considerations
..
11. Acknowledgements
Thanks to Vratko Polak of FD.io CSIT project and Michael Pedersen of
the CNCF Testbed initiative for their contributions and useful
suggestions.
12. References
12.1. Normative References
[RFC2544] Bradner, S. and J. McQuaid, "Benchmarking Methodology for
Network Interconnect Devices", RFC 2544,
DOI 10.17487/RFC2544, March 1999,
<https://www.rfc-editor.org/info/rfc2544>.
[RFC8174] Leiba, B., "Ambiguity of Uppercase vs Lowercase in RFC
2119 Key Words", BCP 14, RFC 8174, DOI 10.17487/RFC8174,
May 2017, <https://www.rfc-editor.org/info/rfc8174>.
12.2. Informative References
[BSDP] "Benchmarking Software Data Planes Intel(R) Xeon(R)
Skylake vs. Broadwell", March 2019, <https://fd.io/wp-
content/uploads/sites/34/2019/03/
benchmarking_sw_data_planes_skx_bdx_mar07_2019.pdf>.
[CNCF-CNF-Testbed]
"Cloud native Network Function (CNF) Testbed", March 2019,
<https://github.com/cncf/cnf-testbed/>.
Konstantynowicz & MikusExpires September 12, 2019 [Page 23]
Internet-Draft NFV Service Density Benchmarking March 2019
[CNCF-CNF-Testbed-Results]
"CNCF CNF Testbed: NFV Service Density Benchmarking",
December 2018, <https://github.com/cncf/cnf-
testbed/blob/master/comparison/doc/
cncf-cnfs-results-summary.md>.
[CSIT-1901-nfv-density-methodology]
"FD.io CSIT Test Methodology: NFV Service Density", March
2019,
<https://docs.fd.io/csit/rls1901/report/introduction/
methodology_nfv_service_density.html>.
[CSIT-1901-nfv-density-results]
"FD.io CSIT Test Results: NFV Service Density", March
2019, <https://docs.fd.io/csit/rls1901/report/vpp_performa
nce_tests/nf_service_density/index.html>.
[CSIT-1901-test-enviroment]
"FD.io CSIT Test Environment", March 2019,
<https://docs.fd.io/csit/rls1901/report/
vpp_performance_tests/test_environment.html>.
[CSIT-1901-testbed-2n-skx]
"FD.io CSIT Test Bed", March 2019,
<https://docs.fd.io/csit/rls1901/report/introduction/
physical_testbeds.html#node-xeon-skylake-2n-skx>.
[draft-vpolak-bmwg-plrsearch]
"Probabilistic Loss Ratio Search for Packet Throughput
(PLRsearch)", November 2018, <https://tools.ietf.org/html/
draft-vpolak-bmwg-plrsearch-00>.
[draft-vpolak-mkonstan-bmwg-mlrsearch]
"Multiple Loss Ratio Search for Packet Throughput
(MLRsearch)", November 2018, <https://tools.ietf.org/html/
draft-vpolak-mkonstan-bmwg-mlrsearch-00>.
[LFN-FDio-CSIT]
"Fast Data io, Continuous System Integration and Testing
Project", March 2019, <https://wiki.fd.io/view/CSIT>.
[RFC8204] Tahhan, M., O'Mahony, B., and A. Morton, "Benchmarking
Virtual Switches in the Open Platform for NFV (OPNFV)",
RFC 8204, DOI 10.17487/RFC8204, September 2017,
<https://www.rfc-editor.org/info/rfc8204>.
Konstantynowicz & MikusExpires September 12, 2019 [Page 24]
Internet-Draft NFV Service Density Benchmarking March 2019
[TRex] "TRex Low-Cost, High-Speed Stateful Traffic Generator",
March 2019, <https://github.com/cisco-system-traffic-
generator/trex-core>.
[TST009] "ETSI GS NFV-TST 009 V3.1.1 (2018-10), Network Functions
Virtualisation (NFV) Release 3; Testing; Specification of
Networking Benchmarks and Measurement Methods for NFVI",
October 2018, <https://www.etsi.org/deliver/etsi_gs/NFV-
TST/001_099/009/03.01.01_60/gs_NFV-TST009v030101p.pdf>.