Network Working Group                                 J. Parello
     Internet-Draft                               Cisco Systems, Inc.
     Intended Status: Informational                September 15, 2011
     Expires: February 15, 2012
     
     
     
                        Energy Management Terminology
                      draft-parello-eman-definitions-02
     
     
     Status of this Memo
     
        This Internet-Draft is submitted to IETF in full conformance
        with the provisions of BCP 78 and BCP 79.
     
        Internet-Drafts are working documents of the Internet
        Engineering Task Force (IETF), its areas, and its working
        groups.  Note that other groups may also distribute working
        documents as Internet-Drafts.
     
        Internet-Drafts are draft documents valid for a maximum of six
        months and may be updated, replaced, or obsoleted by other
        documents at any time.  It is inappropriate to use Internet-
        Drafts as reference material or to cite them other than as
        "work in progress."
     
        The list of current Internet-Drafts can be accessed at
        http://www.ietf.org/ietf/1id-abstracts.txt
     
        The list of Internet-Draft Shadow Directories can be accessed
        at http://www.ietf.org/shadow.html
     
        This Internet-Draft will expire on February, 2012.
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     <Parello, et. Al>      Expires January 27 2012           [Page 1]


     Internet-Draft   <draft-parello-eman-definitions> September 2011
     
     Copyright Notice
     
        Copyright (c) 2011 IETF Trust and the persons identified as the
        document authors.  All rights reserved.
        This document is subject to BCP 78 and the IETF Trust's Legal
        Provisions Relating to IETF Documents
        (http://trustee.ietf.org/license-info) in effect on the date of
        publication of this document.  Please review these documents
        carefully, as they describe your rights and restrictions with
        respect to this document.  Code Components extracted from this
        document must include Simplified BSD License text as described
        in Section 4.e of the Trust Legal Provisions and are provided
        without warranty as described in the Simplified BSD License.
     
     
     
     Abstract
     
        This document contains definitions and terms used in the Energy
        Management Working Group. Each term contains a definition(s),
        example, and reference to a normative, informative or well know
        source. Terms originating in this draft should be either
        composed of or adapted from other terms in the draft with a
        source. The defined terms will then be used in other drafts as
        defined here.
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     <parello>             Expires February 15, 2012          [Page 2]


     Internet-Draft   <draft-parello-eman-definitions> September 2011
     
     
     Table of Contents
     
        1. Introduction................................................3
        2. Terminology.................................................4
           Energy Management...........................................4
           Energy Management System (EnMS).............................5
           ISO Energy Management System................................6
           Energy......................................................6
           Power.......................................................6
           Demand......................................................6
           Power Quality...............................................7
           Electrical Equipment........................................7
           Non-Electrical Equipment (Mechanical Equipment).............7
           Energy Object...............................................7
           Electrical Energy Object....................................8
           Non-Electrical Energy Object................................8
           Energy Monitoring...........................................8
           Energy Control..............................................8
           Energy Management Domain....................................8
           Energy Object Identification................................9
           Energy Object Context.......................................9
           Energy Object Relationships.................................9
           Aggregation Relationship...................................10
           Metering Relationship......................................10
           Power Source Relationship..................................10
           Proxy Relationship.........................................11
           Dependency Relationship....................................11
           Energy Object Parent.......................................11
           Energy Object Child........................................11
           Power State................................................11
           Manufacturer Power State...................................12
           Power State Set............................................12
           Nameplate Power............................................12
        3. Security Considerations....................................12
        4. IANA Considerations........................................12
        5. Acknowledgments............................................13
        6. References.................................................13
           Normative References.......................................13
           Informative References.....................................13
     
     
     
     1. Introduction
     
        Within Energy Management there are terms that may seem obvious
        to a casual reader but in fact require a rigorous and sourced
     
     
     <parello>             Expires February 15, 2012          [Page 3]


     Internet-Draft   <draft-parello-eman-definitions> September 2011
     
        definition.  To avoid any confusion in terms among the working
        group drafts, one glossary / lexicon of terms should exist that
        all drafts can refer to. This will avoid a review of terms
        multiplied across drafts.
     
        This draft will contain a glossary of definitions of terms that
        can be agreed upon by the working group outside of the context
        of drafts and then included in or sourced to this draft.
     
        Each term will contain a definition(s), a normative or
        informative reference, an optional example, an optional
        comment(s) listed a note(s).
     
        All terms should be rooted with a well-known reference. If a
        definition is take verbatim from a reference then the source is
        listed in square brackets. If a definition is derived from a
        well-known reference then the source is listed as "Adapted from"
        with the reference listed in square brackets. If a defined term
        is newly defined here the reference will indicate as such by
        stating "herein" and if applicable list any composing terms from
        this document.
     
        When applicable the [IEEE100] was used as the preferred source.
        If a term was not available from [IEEE100], then [IEC60050] was
        used.  When there were multiple items from [IEEE100], [IEC60050]
        or [ISO50001], there were all included.
     
     2. Terminology
     
     Energy Management
     
       Energy Management is a set of functions for measuring, modeling,
       planning, and optimizing networks to ensure that the network
       elements and attached devices use energy efficiently and is
       appropriate for the nature of the application and the cost
       constraints of the organization.
     
       Reference: Adapted from [ITU-T-M-3400]
     
       NOTE: Energy Management is a system congruent to any of FCAPS
       areas of management in the ISO/OSI Network Management Model
       [TMN]. Energy Management for communication networks and attached
       devices is a subset or part of an organization's greater Energy
       Management Policies.
     
     
     
     <parello>             Expires February 15, 2012          [Page 4]


     Internet-Draft   <draft-parello-eman-definitions> September 2011
     
       Example: A set of computer systems that will poll electrical
       meters and store the readings
     
     
     Energy Management System (EnMS)
     
       1. An Energy Management System is congruent to a Network
       Management System (NMS) and is a combination of hardware and
       software used to administer a network with the primarily purpose
       being Energy Management.
     
       Reference: Adapted from [1037C]
     
       Example: A single computer system that polls data from devices
       using SNMP
     
       2. An Energy Management System (IOS-EnMS) is a set of systems or
       procedures upon which organizations can develop and implement an
       energy policy, set targets, action plans and take into account
       legal requirements related to energy use.  An EnMS allows
       organizations to improve energy performance and demonstrate
       conformity to requirements, standards, and/or legal
       requirements.
     
       Reference: [ISO50001]
     
       Example:  Company A defines a set of policies and procedures
       indicating there should exist multiple computerized systems that
       will poll energy from their meters and pricing / source data
       from their local utility. Company A specifies that their CFO
       should collect information and summarize it quarterly to be sent
       to an accounting firm to produce carbon accounting reporting as
       required by their local government.
     
       NOTE: For the purposes of EMAN, the definition from [1037C] is
       the preferred meaning of an Energy Management System (EnMS).
       The definition from [ISO50001] can be referred to as ISO Energy
       Management System (ISO-EnMS).
     
     
     
     
     
     <parello>             Expires February 15, 2012          [Page 5]


     Internet-Draft   <draft-parello-eman-definitions> September 2011
     
     ISO Energy Management System
     
       Energy Management System as defined by [ISO50001]
     
       Reference: herein
     
     Energy
     
       1. That which does work or is capable of doing work. As used by
       electric utilities, it is generally a reference to electrical
       energy and is measured in kilo-watt hours (kWh).
     
       Reference: [IEEE100]
     
       2. Energy is the capacity of a system to produce external
       activity or perform work
     
       Reference: [ISO50001]
     
     Power
     
       The time rate at which energy is emitted, transferred, or
       received; usually expressed in watts (or in joules per second).
       Reference: [IEEE100]
     
     Demand
     
       The average value of power or a related quantity over a
       specified interval of time. Note: Demand is expressed in
       kilowatts, kilovolt-amperes, kilovars, or other suitable units.
     
       NOTE 1: typically kilowatts
     
       NOTE 2: Energy providers typically bill by Demand measurements
       as well as for maximum Demand per billing periods.  Power values
       may spike during short-terms by devices, but Demand measurements
       recognize that maximum Demand does not equal maximum Power
       during an interval.
     
     
     <parello>             Expires February 15, 2012          [Page 6]


     Internet-Draft   <draft-parello-eman-definitions> September 2011
     
     
       Reference: [IEEE100]
     
     Power Quality
     
       Characteristics of the electric current, voltage and frequencies
       at a given point in an electric power system, evaluated against
       a set of reference technical parameters. These parameters might,
       in some cases, relate to the compatibility between electricity
       supplied in an electric power system and the loads connected to
       that electric power system.
     
       Reference: [IEC60050]
     
     Electrical Equipment
     
       A general term including materials, fittings, devices,
       appliances, fixtures, apparatus, machines, etc., used as a part
       of, or in connection with, an electric installation.
        Reference: [IEEE100]
     
     Non-Electrical Equipment (Mechanical Equipment)
     
        A general term including materials, fittings, devices
       appliances, fixtures, apparatus, machines, etc., used as a part
       of, or in connection with, non-electrical power installations.
        Reference: Adapted from [IEEE100]
     
     
     Energy Object
     
        An Energy Object (EO) is a piece of equipment that is part of or
        attached to a communications network that is monitored,
        controlled, or aids in the management of another device for
        Energy Management.
     
        Reference: herein
     
     
     
     
     
     
     <parello>             Expires February 15, 2012          [Page 7]


     Internet-Draft   <draft-parello-eman-definitions> September 2011
     
     Electrical Energy Object
     
        An Electrical Energy Object (EEO) is an Energy Object that is a
        piece of Electrical Equipment
     
        Reference: herein, Electrical Equipment
     
     Non-Electrical Energy Object
     
        A Non-Electrical Energy Object (NEEO) an Energy Object that is a
        piece of Non-Electrical Equipment.
     
        Reference: herein, Non-Electrical Equipment.
     
     Energy Monitoring
     
       Energy Monitoring is a part of Energy Management that deals with
       collecting or reading measurements from Energy Objects to aid in
       Energy Management.
       NOTE: This could include Energy, Power, Demand, Power Quality,
       Context and/or Battery information.
     
       Reference: herein
     
     Energy Control
     
       Energy Control is a part of Energy Management that deals with
       modifying or setting the state of Energy Objects.
     
       NOTE: Typically in order to optimize or ensure its efficiency.
     
        Reference: herein
     
     Energy Management Domain
     
        An Energy Management Domain is a name or name space that
        logically groups Energy Objects into a zone of Energy
        Management.
     
        NOTE: Typically, this zone will have as members all EO's that
        are powered from the same source.
     
        Reference: herein
     
     
     
     <parello>             Expires February 15, 2012          [Page 8]


     Internet-Draft   <draft-parello-eman-definitions> September 2011
     
        Example: All EEO's drawing power from the same distribution
        panel with the same AC voltage within a building, or all EEO's
        in a building for which there is one main meter, would comprise
        an Energy Management Domain.
     
     
     Energy Object Identification
     
       Energy Object Identification is a set of attributes that enable
       an Energy Object to be: uniquely identified among all Energy
       Management Domains; linked to other systems; classified as to
       type, model, and or manufacturer.
     
       Reference: herein
     
     Energy Object Context
     
       Energy Object Context is a set of attributes that allow an
       Energy Management System to classify the use of the Energy
       Object within an organization.
     
       NOTE: The classification could contain the use and/or the
       ranking of the Energy Object as compared to other Energy Objects
       in the Energy Management Domain.
     
       Reference: herein
     
     
     Energy Object Relationships
     
        Energy Objects may have functional relationships to each other
        within an Energy Management Domain.
     
        NOTE 1: One Energy Object will provide a capability or
        functional value in the relationship and another will be the
        receiver of the capability.
     
        NOTE 2: These capabilities could include Aggregation, Metering,
        Power Source, Proxy and Dependency.
     
        Reference: herein
     
     
     
     <parello>             Expires February 15, 2012          [Page 9]


     Internet-Draft   <draft-parello-eman-definitions> September 2011
     
     Aggregation Relationship
     
       An Energy Object may aggregate the Energy Management information
       of one or more Energy Objects and is referred to as an
       Aggregation Relationship.
     
       NOTE 1: An Energy Object may be aggregated by another Energy
       Object(s).
     
       NOTE 2: Aggregate values may be obtained by reading values from
       multiple Energy Objects and producing a single value of more
       significant meaning such as average, count, maximum, median,
       minimum, mode and most commonly sum.
     
       Reference: Adapted from [SQL]
     
     Metering Relationship
     
        An Energy Object may measure the Energy of another Energy
        Object(s) and is referred to as a Metering Relationship.
     
        NOTE: An Energy Object may be metered by another Energy
        Object(s).
     
        Reference: herein
     
        Example: a PoE port on a switch measures the Power it provides
        to the connected Energy Object.
     
     
     Power Source Relationship
     
        An Energy Object may be the source of or distributor of power to
        another Energy Object(s) and is referred to as a Power Source
        Relationship.
     
        NOTE: An Energy Object may be powered by another Energy
        Object(s).
     
        Reference: herein
     
        Example: a PDU provides power for a connected host.
     
     
     
     
     <parello>             Expires February 15, 2012         [Page 10]


     Internet-Draft   <draft-parello-eman-definitions> September 2011
     
     Proxy Relationship
     
        An Energy Object that provides Energy Management capabilities on
        behalf of another Energy Object so that is appears to be Energy
        Aware is referred to a Proxy Relationship.
     
        NOTE: An Energy Object may be proxied by another Energy
        Object(s).
     
        Reference: herein
     
        Example: a protocol gateways device for Building Management
        Systems (BMS) with subtended devices.
     
     Dependency Relationship
     
        An Energy Object may be a component of or rely completely upon
        another Energy Object to operate and is referred to as a
        Dependency Relationship.  An Energy Object may be dependent on
        another Energy Object(s).
     
        Reference: herein
     
        Example: A Switch chassis with multiple line cards
     Energy Object Parent
     
        An Energy Object Parent is an Energy Object that provides one or
        more of the Energy Object Relationships capabilities.
     
        Reference: herein
     
     Energy Object Child
     
        An Energy Object Child is an Energy Object that has at least one
        Energy Object Relationship capability provided by another Energy
        Object.
     
        Reference: herein
     
     Power State
     
        A Power State is a way to classify an (setting on an Energy
        Object (e.g., on, off, or sleep).
     
     
     
     
     <parello>             Expires February 15, 2012         [Page 11]


     Internet-Draft   <draft-parello-eman-definitions> September 2011
     
        NOTE: A Power State can be viewed as one method for Energy
        Control
     
        Reference: herein
     
     Manufacturer Power State
     
        A Manufacturer Power State is a device-specific way to classify
        a (non)operational implemented on an Energy Object.
     
     Power State Set
     
        A collection of Power States that comprise one named or logical
        grouping of control is a Power State Set.
     
        Reference: herein
     
        Example: The states {on, off, and sleep} as defined in
        [IEEE1621], or the 16 power states as defined by the [DMTF] can
        be considered two different Power State Sets.
     
     
     Nameplate Power
     
        The Nameplate Power is the maximal (nominal) Power that a device
        can support.
     
        NOTE: This is typically determined via load testing and is
        specified by the manufacturer as the maximum value required to
        operate the device.  This is sometimes referred to as the worst-
        case Power.  The actual or average Power may be lower.  The
        Nameplate Power is typically used for provisioning and capacity
        planning.
     
        Reference: herein
     
     
     3. Security Considerations
     
        None
     
     4. IANA Considerations
     
        None
     
     
     
     <parello>             Expires February 15, 2012         [Page 12]


     Internet-Draft   <draft-parello-eman-definitions> September 2011
     
     
     5. Acknowledgments
     
        The author would like to thank the authors of the current
        working group drafts for the discussions and definition
        clarifications
     
     6. References
     
     Normative References
     
     
     Informative References
     
     
        [IEEE100] "The Authoritative Dictionary of IEEE Standards Terms"
                http://ieeexplore.ieee.org/xpl/mostRecentIssue.jsp?punu
                mber=4116785
     
        [IEEE1621]  "Standard for User Interface Elements in Power
                Control of Electronic Devices Employed in
                Office/Consumer Environments", IEEE 1621, December
                2004.
     
        [IEC60050] International Electrotechnical Vocabulary
                http://www.electropedia.org/iev/iev.nsf/welcome?openfor
                m
     
        [ISO50001] "ISO 50001:2011 Energy management systems -
                Requirements with guidance for use",
                http://www.iso.org/
     
        [DMTF] "Power State Management Profile DMTF  DSP1027  Version
                2.0"  December 2009
                http://www.dmtf.org/sites/default/files/standards/docum
                ents/DSP1027_2.0.0.pdf
     
        [TMN] "TMN Management Functions : Performance Management", ITU-T
                M.3400
     
        [ITU-T-M-3400] TMN recommandation on Management Functions
        (M.3400), 1997
     
        [1037C] US Department of Commerce, Federal Standard 1037C,
        http://www.its.bldrdoc.gov/fs-1037/fs-1037c.htm
     
        [SQL] ISO/IEC 9075(1-4,9-11,13,14):2008
     
     
     
     <parello>             Expires February 15, 2012         [Page 13]


     Internet-Draft   <draft-parello-eman-definitions> September 2011
     
     Authors' Addresses
     
      John Parello
      Cisco Systems, Inc.
      3550 Cisco Way
      San Jose, California 95134
      US
     
      Phone: +1 408 525 2339
      Email: jparello@cisco.com
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     <parello>             Expires February 15, 2012         [Page 14]