Networking Working Group JP. Vasseur
Internet-Draft Cisco Systems, Inc
Intended status: Informational September 30, 2008
Expires: April 3, 2009
Terminology in Low power And Lossy Networks
draft-vasseur-roll-terminology-02.txt
Status of this Memo
By submitting this Internet-Draft, each author represents that any
applicable patent or other IPR claims of which he or she is aware
have been or will be disclosed, and any of which he or she becomes
aware will be disclosed, in accordance with Section 6 of BCP 79.
Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF), its areas, and its working groups. Note that
other groups may also distribute working documents as Internet-
Drafts.
Internet-Drafts are draft documents valid for a maximum of six months
and may be updated, replaced, or obsoleted by other documents at any
time. It is inappropriate to use Internet-Drafts as reference
material or to cite them other than as "work in progress."
The list of current Internet-Drafts can be accessed at
http://www.ietf.org/ietf/1id-abstracts.txt.
The list of Internet-Draft Shadow Directories can be accessed at
http://www.ietf.org/shadow.html.
This Internet-Draft will expire on April 3, 2009.
Abstract
The documents defines a terminology for discussing routing
requirements and solutions for networks referred to as Low power and
Lossy Networks (LLN). A LLN is typically composed of many embedded
devices with limited power, memory, and processing resources
interconnected by a variety of links. There is a wide scope of
application areas for LLNs, including industrial monitoring, building
automation (e.g. Heating, Ventilating, Air Conditioning, lighting,
access control, fire), connected home, healthcare, environmental
monitoring, urban sensor networks, energy management, assets
tracking, refrigeration.
Vasseur Expires April 3, 2009 [Page 1]
Internet-Draft draft-vasseur-roll-terminology-02.txt September 2008
Requirements Language
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in RFC 2119 [RFC2119].
Table of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. IANA Considerations . . . . . . . . . . . . . . . . . . . . . . 6
4. Security Considerations . . . . . . . . . . . . . . . . . . . . 6
5. Acknowledgements . . . . . . . . . . . . . . . . . . . . . . . 6
6. References . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6.1. Normative References . . . . . . . . . . . . . . . . . . . 6
6.2. Informative References . . . . . . . . . . . . . . . . . . 6
Author's Address . . . . . . . . . . . . . . . . . . . . . . . . . 7
Intellectual Property and Copyright Statements . . . . . . . . . . 8
Vasseur Expires April 3, 2009 [Page 2]
Internet-Draft draft-vasseur-roll-terminology-02.txt September 2008
1. Introduction
This document defines a terminology for discussing routing
requirements and solutions for networks referred to as Low power and
Lossy Networks (LLN).
Low power and Lossy networks (LLNs) are typically composed of many
embedded devices with limited power, memory, and processing resources
interconnected by a variety of links, such as IEEE 802.15.4, Low
Power WiFi. There is a wide scope of application areas for LLNs,
including industrial monitoring, building automation (HVAC, lighting,
access control, fire), connected home, healthcare, environmental
monitoring, urban sensor networks, energy management, assets tracking
and refrigeration.
Since these applications are usually highly specific (for example
Industrial Automation, Building Automation, ...), it is not uncommon
to see a number of disparate terms to describe the same device or
functionality. Thus in order to avoid confusion or discrepancies,
this document specifies the common terminology to be used in all ROLL
Working Group documents. Terminology specific to a particular
application are out of the scope of this document.
It is expected that all routing requirements documents defining
requirements or specifying routing solutions for LLN will use the
common terminology specified in this document.
2. Terminology
Actuator: a field device that controls a set of equipment. For
example, an actuator might control and/or modulates the flow of a gas
or liquid, control electricity distribution, perform a mechanical
operation, ...
AMI: Advanced Metering Infrastructure that makes use of Smart Grid
technologies. A canonical Smart Grid application is smart-metering.
Channel: Radio frequency sub-band used to transmit a modulated signal
carrying packets.
Channel Hopping: A procedure by which field devices synchronously
change channels during operation.
Commissioning Tool: Any physical or logical device temporarily added
to the network for the expressed purpose of setting up the network
and device operational parameters. The commisioning tool can also be
temporarily added to the LLN for scheduled or unscheduled
Vasseur Expires April 3, 2009 [Page 3]
Internet-Draft draft-vasseur-roll-terminology-02.txt September 2008
maintenance.
Closed Loop Control: A process whereby a device controller controls
an actuator based on information sensed by one or more field devices.
Controller: A field device that can receive sensor input and
automatically change the environment in the facility by manipulating
digital or analog actuators.
DA: Distribution Automation, part of Smart Grid. Encompasses
technologies for maintenance and management of electrical
distribution systems.
Downstream: Data direction traveling from outside of the LLN (e.g.
traffic coming from a LAN, WAN or the Internet) via a LBR.
Field Device: A field deviced is a physical device placed in the
network's operating environment (e.g. plant, urban or home). Field
devices include sensors, actuators as well as routers and Low power
and Lossy Network Border Router (including LBR). A field device is
usually (but not always) a device with constrained CPU, memory
footprint, storage capacity, bandwidth and sometimes power (battery
operated). At the time of writing, for the sake of illustration, a
typical sensor or actuator would have a few KBytes of RAM, a few
dozens of KBytes of ROM/Flash memory, a 8/16/32 bit microcontroller
and communication capabilities ranging from a few Kbits/s to a few
hundreds of KBits/s. Although it is expected to see continuous
improvements of hardware and software technologies, such devices will
likely continue to be seen as resource constrained devices compared
to computers and routers used in the Internet.
Flash memory: non-volatile memory that can be re-programmed.
FMS: Facility Management System. A global term applied across all
the vertical designations within a building including, Heating,
Ventilating, and Air Conditioning also referred to as HVAC, Fire,
Security, Lighting and Elevator control.
HART: "Highway Addressable Remote Transducer", a group of
specifications for industrial process and control devices
administered by the HART Foundation (see [HART]). The latest version
for the specifications is HART7 which includes the additions for
WirelessHART.
HVAC: Heating, Ventilation and Air Conditioning. A term applied to
the comfort level of an internal space.
ISA: "International Society of Automation". ISA is an ANSI
Vasseur Expires April 3, 2009 [Page 4]
Internet-Draft draft-vasseur-roll-terminology-02.txt September 2008
accredited standards-making society. ISA100 is an ISA committee
whose charter includes defining a family of standards for industrial
automation. [ISA100.11a] is a working group within ISA100 that is
working on a standard for monitoring and non-critical process control
applications.
LAN: Local Area Network.
LBR: Low power and lossy network Border Router. The LBR is a device
that connects the Low power and Lossy Network to another routing
domain such as a Local Area Network (LAN), Wide Area Network (WAN) or
the Internet where a possibly different routing protocol is in
operation. The LBR acts as a routing device and may possibly host
other functions such as data collector or aggregator.
LLN: Low power and Lossy networks (LLNs) are typically composed of
many embedded devices with limited power, memory, and processing
resources interconnected by a variety of links, such as IEEE 802.15.4
or Low Power WiFi. There is a wide scope of application areas for
LLNs, including industrial monitoring, building automation (HVAC,
lighting, access control, fire), connected home, healthcare,
environmental monitoring, urban sensor networks, energy management,
assets tracking and refrigeration..
Open Loop Control: A process whereby a plant operator manually
manipulates an actuator over the network where the decision is
influenced by information sensed by field devices.
RAM: Random Access Memory. The RAM is a volatile memory.
RFID: Radio Frequency IDentification.
ROM: Read Only Memory.
ROLL: Routing Over Low power and Lossy networks.
Schedule: An agreed execution, wake-up, transmission, reception,
etc., time-table between two or more field devices.
Sensor: A sensor is a device that measures a physical quantity and
converts it to a analog or digital signal that can be read by a
program or a user. Sensed data can be of many types: electromagnetic
(e.g. current, voltage, power, resistance, ...) , mechanical (e.g.
pressure, flow, liquid density, humidity, ...), chemical (e.g.
oxygen, carbon monoxide, ...), acoustic (e.g. noise, ultrasound), ...
Smart Grid: A Smart Grid is a broad class of applications to network
and automate utility infrastructure.
Vasseur Expires April 3, 2009 [Page 5]
Internet-Draft draft-vasseur-roll-terminology-02.txt September 2008
Timeslot: A Timeslot is a fixed time interval that may be used for
the transmission or reception of a packet between two field devices.
A timeslot used for communications is associated with a slotted-link
Upstream: Data direction traveling from the LLN via the LBR to
outside of the LLN (LAN, WAN, Internet).
WAN: Wide Area Network.
3. IANA Considerations
This document includes no request for IANA action.
4. Security Considerations
Since this document specifies terminology and does not specify new
procedure or protocols, it raises no new security issue.
5. Acknowledgements
The authors would like to thank Christian Jacquenet, Tim Winter,
Pieter De Mil and David Meyer for their valuable feed-back.
6. References
6.1. Normative References
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119, March 1997.
6.2. Informative References
[I-D.ietf-roll-home-routing-reqs]
Brandt, A., Buron, J., and G. Porcu, "Home Automation
Routing Requirement in Low Power and Lossy Networks",
draft-ietf-roll-home-routing-reqs-03 (work in progress),
September 2008.
[I-D.ietf-roll-indus-routing-reqs]
Networks, D., Thubert, P., Dwars, S., and T. Phinney,
"Industrial Routing Requirements in Low Power and Lossy
Networks", draft-ietf-roll-indus-routing-reqs-01 (work in
progress), July 2008.
Vasseur Expires April 3, 2009 [Page 6]
Internet-Draft draft-vasseur-roll-terminology-02.txt September 2008
[I-D.ietf-roll-urban-routing-reqs]
Dohler, M., Watteyne, T., Winter, T., Jacquenet, C.,
Madhusudan, G., Chegaray, G., and D. Barthel, "Urban WSNs
Routing Requirements in Low Power and Lossy Networks",
draft-ietf-roll-urban-routing-reqs-01 (work in progress),
July 2008.
[I-D.martocci-roll-building-routing-reqs]
Martocci, J., Riou, N., Mil, P., and W. Vermeylen,
"Commercial Routing Requirements in Low Power and Lossy
Networks", draft-martocci-roll-building-routing-reqs-00
(work in progress), September 2008.
Author's Address
JP Vasseur
Cisco Systems, Inc
1414 Massachusetts Avenue
Boxborough, MA 01719
USA
Email: jpv@cisco.com
Vasseur Expires April 3, 2009 [Page 7]
Internet-Draft draft-vasseur-roll-terminology-02.txt September 2008
Full Copyright Statement
Copyright (C) The IETF Trust (2008).
This document is subject to the rights, licenses and restrictions
contained in BCP 78, and except as set forth therein, the authors
retain all their rights.
This document and the information contained herein are provided on an
"AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS
OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY, THE IETF TRUST AND
THE INTERNET ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF
THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Intellectual Property
The IETF takes no position regarding the validity or scope of any
Intellectual Property Rights or other rights that might be claimed to
pertain to the implementation or use of the technology described in
this document or the extent to which any license under such rights
might or might not be available; nor does it represent that it has
made any independent effort to identify any such rights. Information
on the procedures with respect to rights in RFC documents can be
found in BCP 78 and BCP 79.
Copies of IPR disclosures made to the IETF Secretariat and any
assurances of licenses to be made available, or the result of an
attempt made to obtain a general license or permission for the use of
such proprietary rights by implementers or users of this
specification can be obtained from the IETF on-line IPR repository at
http://www.ietf.org/ipr.
The IETF invites any interested party to bring to its attention any
copyrights, patents or patent applications, or other proprietary
rights that may cover technology that may be required to implement
this standard. Please address the information to the IETF at
ietf-ipr@ietf.org.
Vasseur Expires April 3, 2009 [Page 8]