   Use Cases and Analysis on Integrated NFV and Network Optimization
               draft-veitch-nfvrg-nfv-nw-optimization-00

Abstract

   This is a review of issues related to the optimized deployment of
   network services, aka service function chains, composed of virtual
   and physical network functions, where these functions may be
   instantiated in multiple distributed data centers.  Criteria for
   optimization are introduced, and use cases are described and
   expanded, in order to establish the need for coordinated computation
   of NF deployment sites and the connectivity among them.  Some methods
   for addressing optimization pain points are described, and potential
   new requirements of the PCE and PCEP are discussed.

   One point to make clear is that the exploration of specific
   algorithms for NF/VNF placement and path computation is outside the
   scope of this draft.  We are not looking at computational or optimal
   greedy search algorithms.  The goals for this draft are 1) to provide
   justification through use cases for more tightly integrating path and
   placement computation algorithms, and 2) looking at how some of the
   optimization requirements might be addressed, mostly through pre-
   computation and caching, and how these might affect management and
   orchestration functions and the protocols (e.g.  PCEP) that are used.

Status of This Memo

   This Internet-Draft is submitted in full conformance with the
   provisions of BCP 78 and BCP 79.

   Internet-Drafts are working documents of the Internet Engineering
   Task Force (IETF).  Note that other groups may also distribute
   working documents as Internet-Drafts.  The list of current Internet-
   Drafts is at http://datatracker.ietf.org/drafts/current/.

   Internet-Drafts are draft documents valid for a maximum of six months
   and may be updated, replaced, or obsoleted by other documents at any
   time.  It is inappropriate to use Internet-Drafts as reference
   material or to cite them other than as "work in progress."

   This Internet-Draft will expire on June 3, 2017.




Veitch                    Expires June 3, 2017                  [Page 1]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


Copyright Notice

   Copyright (c) 2016 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (http://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.  Code Components extracted from this document must
   include Simplified BSD License text as described in Section 4.e of
   the Trust Legal Provisions and are provided without warranty as
   described in the Simplified BSD License.

Table of Contents

   1.  Introduction  . . . . . . . . . . . . . . . . . . . . . . . .   3
   2.  Requirements Language . . . . . . . . . . . . . . . . . . . .   4
   3.  Definitions . . . . . . . . . . . . . . . . . . . . . . . . .   4
   4.  Optimization Criteria . . . . . . . . . . . . . . . . . . . .   5
   5.  Challenge of Network Service (or Service Function Chain)
       Optimization Across Multiple Sites  . . . . . . . . . . . . .   6
   6.  Review of Current NFV / SDN Management Solutions  . . . . . .   6
   7.  Use Cases . . . . . . . . . . . . . . . . . . . . . . . . . .   9
     7.1.  Introduction  . . . . . . . . . . . . . . . . . . . . . .   9
     7.2.  Virtual Content Delivery Network (vCDN) - Dynamic (Flash)
           Delivery  . . . . . . . . . . . . . . . . . . . . . . . .   9
     7.3.  Video Narrowcasting Use Case  . . . . . . . . . . . . . .  12
     7.4.  Real-Time Telemetry Use Case - Internet of Things . . . .  14
     7.5.  High Performance Computing (HPC)  . . . . . . . . . . . .  15
   8.  Orchestration of Mixed Applications and Network Services  . .  16
   9.  Generalized Architecture Options for Coordinated or Unified
       SDN/NFV Deployment Planning . . . . . . . . . . . . . . . . .  17
   10. Analysis of Integrated Network and Compute Optimization with
       a Simple Use Case . . . . . . . . . . . . . . . . . . . . . .  18
     10.1.  Introduction . . . . . . . . . . . . . . . . . . . . . .  18
     10.2.  Network Topology . . . . . . . . . . . . . . . . . . . .  18
     10.3.  Simple Orchestration . . . . . . . . . . . . . . . . . .  19
     10.4.  Connectivity Information in VNF Placement Planning . . .  20
     10.5.  Pre-computation of a Connectivity Matrix . . . . . . . .  21
     10.6.  Multi-valued Connectivity Matrix . . . . . . . . . . . .  22
     10.7.  Additional Optimization Options  . . . . . . . . . . . .  23
     10.8.  Cached Paths Over Multiple Sites . . . . . . . . . . . .  24
     10.9.  Summary  . . . . . . . . . . . . . . . . . . . . . . . .  24
   11. Connectivity based on Potential vs. Actual Topologies . . . .  24
   12. Virtual Networks Equivalency  . . . . . . . . . . . . . . . .  25
   13. Implications for the Network Controllers (SDN / PCE) and



Veitch                    Expires June 3, 2017                  [Page 2]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


       Orchestrators . . . . . . . . . . . . . . . . . . . . . . . .  26
   14. Relationship to TEAS TE Topology and ACTN . . . . . . . . . .  26
   15. Areas of Future Evaluation  . . . . . . . . . . . . . . . . .  27
   16. IANA Considerations . . . . . . . . . . . . . . . . . . . . .  27
   17. Security Considerations . . . . . . . . . . . . . . . . . . .  28
   18. References  . . . . . . . . . . . . . . . . . . . . . . . . .  28
     18.1.  Normative References . . . . . . . . . . . . . . . . . .  28
     18.2.  Informative References . . . . . . . . . . . . . . . . .  28
   Author's Address  . . . . . . . . . . . . . . . . . . . . . . . .  29

1.  Introduction

   With the advent of Network Function Virtualization (NFV), network
   services, consisting of an ordered set of network functions (NFs),
   may be composed of physical (PNF) and virtual network functions
   (VNF).  These VNF will execute in one or more virtual machines or
   containers operating on standard high performance servers.  The set
   of network functions for a given network service might be
   instantiated within a single site or the network service might be
   multi-site.

   This document is a brief examination of issues related to the
   optimized deployment and operations of network services, and in
   particular, multi-site network services.  It includes a review of use
   cases that reveal possible limitations in current NFV and SDN
   management architectures, as defined in some standards and open
   source projects, and related communications protocols.

   The use cases described include the virtualization of support for
   Content Delivery Networks (CDN), Internet of Things, video
   narrowcasting, and high performance computing.  In this analysis, an
   important consideration is the shared infrastructure among a variety
   of applications and services.  Sharing the infrastructure has the
   advantage of increasing overall utilization of the infrastructure vs.
   support for dedicated solutions for each service type.  One can
   imagine disjoint networks for each of the services being implemented,
   with the result being a very high total cost to the provider and
   consumer.

   Another advantage is that the resource utilization profiles for each
   of these services will differ.  High performance computing might
   require a good deal of computational power and memory, which
   translates into requiring many CPU, virtualized CDN require a large
   amount of storage, and the main requirements for video services might
   be low latency and jitter in the delivery of its traffic from its
   source to its consumers.





Veitch                    Expires June 3, 2017                  [Page 3]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


   An understanding of the expected resource usage for different
   services and network functions will allow intelligent placement of
   these services, not just to provide the user a high quality of
   experience (QoE), but also provide the operator with a lower CAPEX
   through smarter utilization of the resources.

   One of the goals in reviewing these use cases is to understand the
   common information that is necessary for an operator to effectively
   provide optimal solutions for the various services to be supported,
   and their disparate requirements.

2.  Requirements Language

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
   document are to be interpreted as described in RFC 2119 [RFC2119].

3.  Definitions

   Note: This document includes concepts and terminology used in both
   the IETF and in the ETSI NFV ISG.  A number of concepts are shared or
   have very similar counterparts between the groups.  Here are some of
   the key terms used and their definitions.

   o  Management and Orchestration (MANO) - Describes the architecture
      framework to manage NFVI and orchestrate the allocation of
      resources needed by the NSs and VNFs.

   o  Network Function (NF) - A functional block within a network
      infrastructure, that has well-defined external interfaces and a
      well-defined functional behavior.

   o  Virtual Network Function (VNF) - Implementation of an NF that can
      be deployed on a Network Function Virtualisation Infrastructure
      (NFVI).  IETF corollary is the Service Function or SF in SFC.

   o  NFV Infrastructure (NFVI) - The NFV-Infrastructure is the totality
      of all hardware and software components which build up the
      environment in which VNFs are deployed.  It may span across
      several sites, e.g. where data centers operate.

   o  NFVI-PoP - Where a Network Function is or could be deployed as
      Virtual Network Function (VNF)e

   o  Network Function Virtualization Orchestrator (NFVO) - functional
      block that manages the Network Service (NS)lifecycle and
      coordinates the management of NS lifecycle, VNF life cycle and




Veitch                    Expires June 3, 2017                  [Page 4]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


      NFVI resources to ensure an optimized allocation of the necessary
      resources and connectivity

   o  Network service (NS) - A composition of network functions and
      defined by its functional and behavioral specification.

   o  VNF Forwarding Graph (VNFFG) - A NF forwarding graph where at
      least one node is a VNF.

   o  Multi-site network service - A service that has component network
      functions operating in infrastructure located in separate
      geographical sites.  These sites may consist of a combination of
      customer sites and operator data centers.  Service components are
      therefore connected across wide area networks (WANs.)

4.  Optimization Criteria

   One question to be asked, when we mention optimization, is, what is
   it that we want or need to optimize when a network service or
   services are to be deployed?  And the answer is that there are a
   number of criteria we would like to see maximized or minimized, some
   of which lead in opposite directions.

   o  Maximize the likelihood a requested network service will be
      honored and instantiated, and not rejected due to a lack of
      available resources to meet the service's SLAs.

      For a multi-site service, it is important that the site of the
      network functions and the connectivity between them be selected to
      ensure any SLA requirements are met.  The search for a solution
      should not fail when adequate resources exist to support the
      service request.

   o  Maximize the health of a network service and minimize the
      likelihood that service might fail to meet its service level
      agreements, or SLAs, during its lifetime.

      Each network service deployed must meet an SLA, with a penalty
      likely imposed should the service fail to do so.  These SLAs will
      include metrics such as Availability, throughput or bandwidth,
      loss, latency, maximum outage time, mean time between failures,
      etc.  Goals include minimizing the risk of any single service
      failing to meet its SLAs, as well as minimizing the overall number
      of services that fail to meet their SLAs.

   o  Minimize the time it takes to respond to a network service request
      with an instantiation of that service.  Alternatively, a request
      may ask only for the set of resources to support a network



Veitch                    Expires June 3, 2017                  [Page 5]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


      service, but not to actually deploy the services.  The response
      time for this request should also be minimized.


   o  Maximize the utilization of the network and compute
      infrastructure, or NFVI, to achieve OPEX and CAPEX savings.

      One promise of NFV is the reduction of OPEX and CAPEX.  In other
      words, with greater flexibility and finer grained control, the
      better a management system can utilize the NFVI.  CAPEX is clearly
      lower when less total NFVI is used, and OPEX should be too.  For
      example, excess hardware may be hibernated when not needed, saving
      energy costs and management costs.

5.  Challenge of Network Service (or Service Function Chain)
    Optimization Across Multiple Sites

   When deploying a network service, it is important to place the
   component network functions (PNF/VNF) in sites to deliver an
   optimized network service, as based on the criteria listed above.
   Deciding how and where to deploy the VNFs is made more complex when
   the network service is to be deployed across multiple sites.

   A network service descriptor includes a set of NFs and links that
   represent connections between pairs of the network functions.
   Associated with each link might be a set of criteria, e.g. latency,
   bandwidth, etc., that an instance of the service must meet.  When NFs
   are to be placed in different sites and separated by one or more
   networks, both the sites of the NFs and the connectivity paths
   between the pairs must be selected to meet the NF and connectivity
   requirements defined for the network service and its components.
   This means that choosing the placement of the VNFs and selecting
   their connectivity are interdependent activities.

6.  Review of Current NFV / SDN Management Solutions

   Today a number of management and orchestration architectures for NFV
   based services have been defined and are described by standards
   organizations, open source projects, as well as some service
   providers.  The ETSI NFV ISG described the original NFV management
   architecture: The Management and Orchestration of NFV based network
   services, commonly referred to as MANO, was defined in phase 1 of the
   ISG work program.

   Since then, other standards bodies have addressed the architecture,
   and a number of software projects undertaken to develop management
   systems, based on, or strongly influenced, by the ETSI MANO
   architecture.  These include, but are not limited to:



Veitch                    Expires June 3, 2017                  [Page 6]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


   o  Lifecycle Service Orchestration (LSO) from the Metro Ethernet
      Forum (MEF)

   o  Open Source MANO (OSM), also sponsored by ETSI

   o  Open Platform NFV (OPNFV) from Linux Foundation

   o  SONATA

   o  Openstack, including Tacker, and networking-sfc

   o  Open-O

   o  Enhanced Control, Orchestration, Management and Policy (ECOMP)
      from ATT

   o  TMForum architecture

   These architectures generally follow two paradigms.  Each includes an
   End-2-end (E2E) orchestrator that is responsible for overall
   orchestration of network services, including the VNFs, PNFs and
   network connectivity.  This E2E orchestrator then communicates with
   an NFVO, an orchestrator for the network services based on the VNFs.
   Where they differ is in how the network controller, often an SDN
   controller, fits.  In most of these, the E2E controller communicates
   directly to both the NFVO and the network controller.  In others the
   NFVO communicates to the network controller.
























Veitch                    Expires June 3, 2017                  [Page 7]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


+----------------------------------------------------------------------+
|                           E2E Orchestration                          |
+----------+------------------------+------------------------+---------+
           |                        |                        |
           |                        |                        |
+----------+---------+   +----------+---------+    +---------+---------+
| WAN SDN Controller |   | DC SDN Controller  |    |       NFVO        |
+----------+---------+   +----------+---------+    +---------+---------+
           |                        |                        |
           |                        |              +---------+---------+
           |                        |     ---------+       VIM         |
           |                        |     |        +---------+---------+
           |                        |     |                  |
 ----------+--------      ----------+-----+--      +---------+---------+
(   WAN Networks    )    (    DC Network     )     |       VNFs        |
 -------------------      -------------------      +-------------------+


+----------------------------------------------------------------------+
|                           E2E Orchestration                          |
+-----------------------------------+----------------------------------+
                                    |
                                    |
                         +----------+---------+
           +-------------+         NFVO       +--------------+
           |             +----------+---------+              |
           |                        |                        |
           |                        |                        |
+----------+---------+   +----------+---------+    +---------+---------+
| WAN SDN Controller |   | DC SDN Controller  +----+       VIM         |
+----------+---------+   +----------+---------+    +---------+---------+
           |                        |                        |
           |                        |                        |
 ----------+--------      ----------+--------      +---------+---------+
(   WAN Networks    )    (    DC Network     )     |       VNFs        |
 -------------------      -------------------      +-------------------+

    Two typical paradigms of network service orchestration seen in open
                       source and SDO architectures.

                                 Figure 1

   The key point is that in both paradigms the NF deployment decisions
   and connectivity decisions are controlled by separate functions.  As
   described in literature to date, the functionality described for
   each, and the information to be exchanged, is not adequate to avoid
   potential inefficiencies and unnecessary network service deployment




Veitch                    Expires June 3, 2017                  [Page 8]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


   failures, due to the real interdependence these functions have upon
   each other.

   Of course, these architectures are currently undergoing active
   development through open and iterative design processes.  Therefore,
   the state of these designs is very fluid, with new capabilities
   continuously evolving.  Therefore, the description provided here
   represents only a moment in time.  This document is intended to
   provide insight into possible limitations that exist in computing
   deployment solutions and to recommend updates to functional block
   capabilities and communications (perhaps leading to protocol
   updates), that will lead to improving these computations.  It is
   expected that as these projects evolve, this draft too will evolve,
   further clarifying roles, communications, and needed extensions.

7.  Use Cases

7.1.  Introduction

   The following are a set of network service examples that demonstrate
   the value of coordinated or unified compute and network deployment
   and configuration planning.

7.2.  Virtual Content Delivery Network (vCDN) - Dynamic (Flash) Delivery

   The following are a set of network service examples that demonstrate
   the value of coordinated or unified compute and network deployment
   and configuration planning.

   ETSI and other groups have identified virtual CDN (vCDN) as an
   application well suited to operate as an NFV network service.  As 5G
   is adopted and bandwidth greedy applications such as UHD video
   proliferate, mobile data will have a huge impact as a source of
   network traffic.  CDNs have a proven track record as an effective way
   to provide high quality and low latency delivery of content to users,
   while simultaneously limiting the overall utilization of network
   bandwidth.  Operators need to continue to provide a high quality
   service while limiting provisioning unnecessary infrastructure.
   Virtual CDNs are seen as an excellent way to address these new
   pressures.

   There are some obvious advantages to a virtualized solution.  The
   costs will shift from CAPEX to OPEX as the vCDN can operate on
   standard high capacity servers.  More importantly, a software-based
   solution enables rapid configuration of the vCDN, faster upgrades of
   the software, and mobility of the vCDN vCaches.  With vCDN it is
   possible to dynamically and intelligently size the vCaches, and move
   them to sites where they provide the best value, based upon the



Veitch                    Expires June 3, 2017                  [Page 9]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


   current and anticipated near-term traffic volumes and patterns.  More
   ephemeral demands for content can be more effectively managed.

   The SONATA Use Cases and Requirements document (http://www.sonata-
   nfv.eu/content/d21-use-cases-and-requirements) categorizes two types
   of vCDN scenarios.

   First is the more traditional distribution of popular content.
   Content originates at a content provider and it is distributed on
   vCaches located as needed for a large number of subscribers.

   The second scenario is concerned with user-generated content and is
   much more dynamic.  This is the one that is examined here.  This is a
   'flash' vCDN, one where the need for a CDN is due to a sudden burst
   of content, one with a limited expected lifetime.  One example might
   be any large sporting event that many people attend.  These attendees
   will likely take and post multiple videos to the Web with a social
   media application, and then they and their friends will view and
   download these videos multiple times.  During the event there will a
   real need to support caching this content and making it available to
   consumers while limiting network impact.






























Veitch                    Expires June 3, 2017                 [Page 10]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


                 +-----------+
              +--+ End Users |                     +-----------+
              |  +-----------+---------------------| End Users +---+
   +---+------+  ------/         WAN         \---  +-----------+   |
   |   Data   |-/                                   \---   +-------+--+
   |  Center  +-                                         \ |   Data   |
   | NFVI-PoP | \@                                        -+  Center  |
   +----------+    \@                                   @/ | NFVI-PoP |
      |               \@                            @/     +----------+
        -\               \@                     @/        /-
          --\               \@              @/         /--
             ---\              \@       @/         /---
                 ---+-------------\---/--------+----
                    |  Data Center (NFVI-PoP)  |
                    | +---------+  +---------+ |
                    | | vCache  |  | vCache  | |
           ----     | +---------+  +---------+ |     -----
        --/         +---+-------------------+--+          \--
       (               |  Access Network    \                )
        --\            /                     |            /--
           --------\  |                      \   /--------
                    --/-----------------------\--
                    |                      +---------+-----+
          +----------+----+                | Media Content |
          | Media Content |                |    Creator    |
          |    Creator    |                +---------------+
          +---------------+

    Topology of vCDN use case with a rapid short term need for content
                                 caching.

                                 Figure 2

   The challenge for this use is for the provider to be able to rapidly
   deploy and configure the a vCDN solution so that the users' QoE is
   high, both the sources and the consumers, while the resource
   utilization, mostly the WAN connectivity, is minimized.

   In this use case the placement of the vCaches is driven by a number
   of factors, including the proximity to the users posting the videos,
   the proximity to users consuming the videos, the available network
   capacity among the data centers, reliability (availability) depending
   upon the service, the costs of the data center servers, and the cost
   of the network, if connectivity requires transit across a third
   party's network.  This is not simply a matter of identifying the data
   centers and then connecting them.  Candidate sites must be
   identified, connectivity options must be identified, and the
   combination of these must be evaluated in the context of the factors



Veitch                    Expires June 3, 2017                 [Page 11]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


   listed above, past and current performance measurements, and any
   provider or user policies.  Multiple deployment options may be
   considered, with one selected to provide an optimal solution.

   As this will be a dynamic vCDN deployment, frequent monitoring of
   demand and delivery metrics is a major necessity, and redeployments
   and upgrades, or possible reductions when demand wanes, must be
   addressed with no unnecessary delay.

7.3.  Video Narrowcasting Use Case

   Video narrowcasting is a targeted delivery of video (and audio)
   content to multiple consumers, perhaps from the tens to low
   thousands, and delivery is generally expected to be broadcast
   quality.  This is not broadcast television, but might be used for
   distance training, or education, or internal communications within
   large organizations.  It is also a term used to describe the delivery
   of commercial television to a niche audience, e.g. from a cable
   service provider.  This differs from popular microcomputer based
   applications such as Skype or weChat, as high quality (high
   definition), high availability and very low latency are expected.

   In some cases, there will be more than one video source; you can
   imagine a presentation where presenters are based in different sites,
   and in some of these cases, the video encodings might differ from the
   different sources.  In addition, lower quality video and audio might
   be available for users to send feedback to the primary sources.

   A number of factors must be examined when choosing how to support
   this service.  These include, the number of sources, their sites,
   their encoding capabilities, and the bandwidth available over which
   each can send.  Also to be considered are the receivers, their number
   and site, their bandwidth capacity over which to receive the videos,
   and their codecs.  How many incoming video streams can the receiver
   process at once.

   Today there are commercial hardware and software products and
   packages to provide this capability.  These, however, can be costly
   and are not very flexible.

   You can imagine a number of situations.  The simplest would be if all
   senders have the same video codec, all receiver codecs can decode as
   many incoming video streams as needed, and all senders and receivers
   have more than enough bandwidth for sending or receiving, and high
   usage of WAN links is not a problem.  When this is true there is very
   little service management needed.  Unfortunately, this is unlikely.





Veitch                    Expires June 3, 2017                 [Page 12]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


                 +-----------+
              +--+ End Users |                     +-----------+
              |  +-----------+---------------------| End Users +---+
   +---+------+  ------/         WAN         \---  +-----------+   |
   |   Data   |-/                                   \---   +-------+--+
   |  Center  +-                                         \ |   Data   |
   | NFVI-PoP | \@@                                       -+  Center  |
   +----------+    \@                                   @/ | NFVI-PoP |
      |               \@                            @/     +----------+
        -\               \@                    @/       /-
          --\               \@             @/        /--
             ---\              \@     @@/         /---
                 +----------------\---/-------------+
                 |     Data Center (NFVI-PoP)       |
                 | +---------+ +-------+ +--------+ |
                 | |  video  | | video | | video  | |
                 | | process | |  mgmt | | server | |
           ----  | +---------+ +-------+ +--------+ | ----
        --/      +-----+--------------------+-------+      \--
       (               |  Access Network    \                )
        --\            /                     |            /--
           --------\  |                      \   /--------
                    --/-----------------------\--
                    |                      +---------+-----+
          +----------+----+                |     Video     |
          |     Video     |                |     Source    |
          |     Source    |                +---------------+
          +---------------+

                     Topology of video narrowcasting>.

                                 Figure 3

   More likely is that some of the following are true and must be
   addressed.

   There are multiple senders with different coding capabilities, or
   different bandwidths available over which to send.  In addition, some
   of the receivers do not have the video codecs to decode some of the
   sender encodings, or lack the bandwidth over which to receive the
   packets of the high definition video.

   When this is true, functions must be installed into the network to
   manage these issues properly.  Video processing can be added to mix
   video of different sources, if necessary for some consumers to see
   multiple senders.  Consumers may even remotely control this
   processing, on demand.  Other processing may be needed to compress
   the video, with the effect of lowering its quality, but making it



Veitch                    Expires June 3, 2017                 [Page 13]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


   possible for consumers with limited bandwidth (e.g. mobile) to see
   it.  These and many other factors will drive selecting where to place
   these functions, connect them to one another, and how to forward
   these to the end consumers (e.g. what IP multicast groups, etc.), all
   to provide the best QoE while limiting resource consumption.

   The evaluation of these factors may quickly become complex, and may
   be continuous as consumers join and leave.  The placement of the VNFs
   will depend greatly on network connectivity, capacity and latency, as
   well as the potential to provide connections directly over electrical
   or optical, vs. multi-hop packet.

7.4.  Real-Time Telemetry Use Case - Internet of Things

   The Internet of Things (IoT) is growing exponentially and will be a
   huge source of information to be communicated across the Intenet in
   the coming years.  This use case in concerned with a large number of
   sensors being activated over a short amount of time.  One example of
   this could include a large sporting event, e.g. the Boston Marathon,
   with multiple thousands of competitors wearing health-monitoring
   applications that communicate vital signs as telemetry over the
   Internet.  Or this could be relevant for a natural disaster (or man-
   made disaster.)  Sensors might be deployed, or simply activated to
   report much more data, because of an incoming hurricane, or a
   volcanic eruption, tornado, forest fire, or tsunami and
   infrastructure emergencies.  This could necessitate the creation of a
   new IoT gateway and other associated components located nearer to the
   sensors and with the capacity to forward the data in real-time to its
   consumers.

   This use case is quite similar to the flash vCDN use case described
   above.  Here, instead of vCaches, we have IoT gateways.  Instead of
   cameras taking videos to be uploaded and downloaded, we have sensors,
   to be processes and forwarded in real-time to the consumers.  This is
   a case where low latency, and perhaps low jitter, is required, though
   high throughput less so.  Again, these network requirements might
   impact the placement of the gateways and their connectivity.

   A further complexity is introduced when we consider these sensors to
   be mobile.  One example will be with self-driving cars, or even human
   driven cars, but where there are many more sensors.  The vehicles
   will generate a great deal of data which must travel over the
   wireless access networks to the nodeBs, behind which will be IoT
   gateways to process the data and forward the relevant data in real
   time to other functions.  These might automatically change driving
   routes, maximum speeds for some roads, etc.





Veitch                    Expires June 3, 2017                 [Page 14]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


   In this scenario it seems likely that different areas will have
   different loads of network sensor data based upon the time of day.
   There will be low volumes during the day, with greater volumes during
   rush hour.  And these will migrate from city or industrial areas, to
   suburbs.  (Just as, no doubt, today the cell phone calls managed in
   different areas depend upon the time of day.)  Virtual IoT gateway
   deployments and the connectivity among the gateways and telemetry
   consumers will there for also be varied.  This is more predictable,
   but deployment options must still consider connectivity, network
   utilization, etc. when placing the vIoT gateways, etc.  There are
   also likely more dynamic mobile scenarios to be reviewed, e.g.
   travelers evacuating an area due to a hurricane, etc.

7.5.  High Performance Computing (HPC)

   Note: A number of concepts here are taken from 'HPC-Aware VM
   Placement in Infrastructure Clouds', by Gupta et al.

   High performance computing (HPC) in the cloud promises to expand the
   number of computing applications that can be supported and will lower
   costs over all.  However, HPC has a number of requirements that place
   significant demands upon the compute and networking infrastructure.

   Included among these are the need to 1) periodically move huge
   volumes of data among distributed applications as well as 2) support
   multiple processes that are tightly coupled and require frequent
   communications and synchronizations.  In addition, for some large
   computations, there may be the need to rapidly expand to very large
   numbers of collocated VNFs for large computations with very strict
   synchronization time windows.

   There is active research today for improving VM scheduling, hardware
   utilization, how best to partition clusters for different application
   types, and map functions to sites to maximize utilization.

   When considering some of these demands, a few things are clear.  For
   communicating large volumes of data, it will be necessary to dedicate
   significant bandwidth at times and limit latency.  When supporting
   HPC as a service a provider must anticipate these sorts of needs, and
   ensure the infrastructure resources supporting other services are
   utilized such that the capacity to meet this sort of demand is
   possible without the need to migrate services and VNFs.

   When the resource requirements of cooperating applications recommend
   locating the applications in separate data centers and the
   application's synchronized communications requirement demands
   connectivity of a high bandwidth circuit, the provider must ensure
   both the data center infrastructure and connectivity between the



Veitch                    Expires June 3, 2017                 [Page 15]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


   datacenters meet the service requirements.  In this case, while a
   circuit may not exist, the function computing the connectivity should
   be aware of the potential circuit, for situations such as supporting
   this network service.

8.  Orchestration of Mixed Applications and Network Services

   The use cases listed above place a variety of disparate demands upon
   the data center (NFV-IPoP) and network infrastructure.  For each
   individual network service instance, a service deployment algorithm
   may compute the sites and connectivity for that specific instance.
   These computations are made in the isolation of the context of that
   specific service instance, perhaps over its lifecycle.

   However, there is a need to consider and manage overall delivery and
   support of these individual services.  As has been described above,
   it is beneficial to deploy across the data centers a balanced
   distribution of network service components with different resource
   requirement profiles.  This will help to optimize the utilization of
   the data center and network infrastructure.  And in circumstances
   when some of the services are known to place specific large demands
   on infrastructure, for example, instantiating an ODU circuit to
   provide high bandwidth real-time communications, some agent must be
   aware of this sort of demand to ensure it is met.

   This implies that there could be some sort of higher-level agent, one
   that works with the agents (e.g.  NFVO and SDN controller) computing
   compute and network deployments for individual requested service
   definitions.  This higher layer agent must ensure that resources are
   allocated properly so that those agents compute deployments that also
   honor the greater goals, e.g. the balanced distribution of
   heterogeneous services, resources ready for specific demands of some
   of the services, general reduced energy consumption and lower costs,
   etc.  These should lead to the optimization goals described at the
   beginning of this paper.

   The exact communications that might be required to support this
   should be explored.  These could impact the controller NBI or the PCE
   pro tocol.












Veitch                    Expires June 3, 2017                 [Page 16]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


   +-----------------------------+
   |     E2E Orchestration       |
   |              +------------+ |
   |              |   General  | |
   +------+------ |Optimization|-+
          |       +-------+----+
          |     -/        |
          |   -/          |
   +------+--+--+   +-----+------+
   |            |   |  Network   |
   |    NFVO    |   | Controller |
   |            |   |(PCE / SDN) |
   +------------+   +------------+

     Shows an agent that tracks usage to provide guidance for general
                               optimization.

                                 Figure 4

9.  Generalized Architecture Options for Coordinated or Unified SDN/NFV
    Deployment Planning

   To achieve the integrated NFV/SDN optimization goals requires a
   software system that computes the optimizations for compute and
   network.

   One option would be to replace the separated agents, the NFVO and SDN
   controller, with a single unified agent that processes the network
   topology, configuration and utilization, as the PCE / SDN controller
   does today, and computes the VNF placement, as the NFVO does today.
   If we look at the E2E Orchestrator in Figure 1, one option is for the
   network SDN controller and the NFVO to send full topology and NFVI
   (data center topology, compute et al resources and existing use and
   utilization) information to the E2E Orchestrator, where it is the
   unified agent, computing the optimal deployment, computing the path
   and NFVI allocations, and then directing specific actions of the PCE
   / SDN agent and NFVO to deploy the updates.

   Alternatively, the functionality of the NFVO and SDN Controller
   remain mostly consistent.  Each fills its current set of
   responsibilities, the PCE computing paths and the NFVO planning NFVI-
   PoP updates with the new VNF instances.  If this is done, then
   enhancements must be made so these agents coordinate and compute the
   best overall deployment.







Veitch                    Expires June 3, 2017                 [Page 17]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


10.  Analysis of Integrated Network and Compute Optimization with a
     Simple Use Case

10.1.  Introduction

   Here is presented a simple network service, composed of two VNFs
   (SFs) across two data centers.  This could be a vCPE service with a
   remote VNF.  This simple case is used here to provide a basis on
   which to explore how network services (SFCs) may be orchestrated.
   Solutions for the simple case are examined iteratively, each new
   version presenting more advanced orchestration capabilities that
   address deficiencies identified in the previous version.  The purpose
   here is not to examine any path computation optimization algorithms.
   It is intended to demonstrate how other methods, including pre-
   computation and/or memoization, might aid in meeting the optimization
   goals, and what this might mean for network topology modeling and
   protocol definitions.

   Note: Many concepts in the TE Topology model currently being defined
   in the TEAS WG, can be considered relevant to this work.  The
   intention of this section is to describe the general problem and
   approach.  How this relates to the concepts and models defined in the
   TE Topology is explored in the next section of this document.

   +------------------+       +-------+           +-------+
   | Service Endpoint |       |       |           |       |
   | (Cust. Premises) +-------+ VNF A +-----------+ VNF B |
   |                  |       |       | 3GB req.  |       |
   +------------------+       +-------+           +-------+

                          Shows an architecture.

                                 Figure 5

10.2.  Network Topology

   The topology includes three data centers and a user enterprise site,
   where the a user service endpoint is located.

   Two variations are used.  In the first, tunnels are already
   established among the data centers.  In the second, a tunnel is
   established specifically to support the link between the network
   functions.








Veitch                    Expires June 3, 2017                 [Page 18]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


                     +-------------+                     +-------------+
+-----------------+  |             |                     |             |
|Service Endpoint |  | Data Center |   --------  2 GB    | Data Center |
|(Cust. Premises) +--+ (NFVI-PoP)  +--(   WAN  )---------+  (NFVI-PoP) |
+-----------------+  |             |   ----+--- Available|             |
                     +-----|-------+       |             +------+------+
                                           |
                                           |
                                           |
                                           |             +------+------+
                                           |             |             |
                                           |   5 GB      | Data Center |
                                           +-------------+ (NFVI-PoP)  |
                                              Available  |             |
                                                         +-------------+

   The network topology available for establishing connectivity for the
                             network service.

                                 Figure 6

10.3.  Simple Orchestration

   In this example the computation of the VNF deployment sites occurs
   first, followed by the connectivity solution.  There is only one link
   property to be met, minimum bandwidth, and for the link between VNF A
   and VNF B, the minimum acceptable bandwidth of 2 GB .  (Note: This is
   shown in the labels of the links in Figure 6.)

   Here are the actions and events involved in planning the creation of
   a service instance.

   o  Orchestration software receives the network service request.

      The request includes descriptors, including resource requirements,
      for each VNF (SF) and the links between them.  For the VNFs, this
      includes the number of needed containers (a VNF may be composed of
      multiple VNFCs), compute, memory, and storage.  For the links this
      includes bandwidth, latency, jitter, and loss.

   o  Orchestrator identifies the data centers based on proximity to the
      user site, and the availability of servers with the resources to
      meet the VNF (SF) resource requirements and any relevant policies.

      At this point, the choice of data centers for the VNF has been
      finalized.





Veitch                    Expires June 3, 2017                 [Page 19]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


   o  Orchestrator requests the network controller to establish
      connectivity for each virtual link connecting VNFs in the network
      service description.

      A path must be found between each pair of VNF, one which can
      provide the minimum bandwidth associated with the virtual link
      between those VNF.  NOTE: If no suitable path is found, then the
      network service deployment FAILS.

   +-----------------+  +-------------+                +-------------+
   |Service Endpoint |  | Data Center |                | Data Center |
   |(Cust. Premises) +--+ (NFVI-PoP)  |         3 GB   | (NFVI-PoP)  |
   +-----------------+  | +---------+ |  -----  Needed | +---------+ |
                        | |  VNF A  +---( WAN )----------+  VNF B  | |
                        | +---------+ |  -----  2GB    | +---------+ |
                        +-------------+         Avail. +-------------+

     >Inadequate bandwidth for service with VNF placement computed in
                                 advance.

                                 Figure 7

10.4.  Connectivity Information in VNF Placement Planning

   An obvious deficiency of this process is in choosing VNF sites
   without considering the ability of the network to provide the
   necessary connectivity and bandwidth.  The solution is to update the
   orchestrator to consider connectivity as a factor when computing
   where the VNF should be placed.  Whatever the placement algorithm, it
   must ensure that VNFs, connected by a virtual link in a network
   service definition, have supporting network connectivity that will
   meet the service requirements, e.g. bandwidth, or latency, associated
   with that virtual link.

   Compared to the previous solution, here the network service
   deployment algorithm will place a VNF in a datacenter only if network
   connectivity is acceptable.  If an orchestrator chooses to place a
   VNF in a datacenter, then the next VNF in the service path must be
   placed in a site where connectivity between the two meets the
   requirements in the virtual link description.

   A simple backtracking algorithm, such as depth first search (DFS),
   will start at the front of the service and check on possible next hop
   data centers (including the 'current' one).  It will choose one based
   on proximity, available compute, storage, etc. resources, policies,
   etc.  It will then request of the PCE or SDN controller to compute a
   path to the candidate data center, passing the virtual link
   requirements, e.g. bandwidth, latency etc.  The PCE/controller should



Veitch                    Expires June 3, 2017                 [Page 20]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


   consider the topology, currently allocated bandwidth, traffic volumes
   and profile, hop count, encapsulations, etc. in computing paths.
   This will continue until either all options have been searched
   unsuccessfully, or until a successful set of data centers and paths
   between them is found.  Of course, DFS will not be used, as there are
   much more efficient heuristic algorithms available.  But the concept
   is the same regardless of the algortihm.  Connectivity information is
   utilized when choosing VNF sites.

   One problem with this solution is the need to have the PCE or SDN
   controller compute a path each time connectivity between two data
   centers is to be checked.  This will take a fair amount of time and
   CPU cycles.  Efficiency can be improved through memoization of the
   path computation and its result, the first time the PCE or SDN
   controller returns a value.  Before asking the PCE to compute a path,
   a check of the cache, for the result of any earlier computation, can
   be made.  Keys would be the endpoint data centers, the network
   service ID and the virtual link ID.

10.5.  Pre-computation of a Connectivity Matrix

   One problem identified in the previous solution is the number of
   delays that accumulate due to repeated path requests to the PCE/
   controller.  Memoization is identified as a method for reducing the
   impact.  Nevertheless, the response time to instantiate a service
   will be longer than it need be.  For a network service with m VNF
   (SF), if each is in a separate site, then, at best, m-1 requests to
   the PCE/controller are required.  If there are problems finding
   paths, the count of path computations rises.  This has the potential
   to be computationally costly and require a lot of time before
   providing a satisfactory solution.

   A better solution would be to pre-compute connectivity among the
   sites and make this available for the algorithm.  This will likely
   increase the overall compute load, but it would shorten the time to
   respond to service requests.  In this case a connection is computed
   for each pair of data centers and possible endpoints (user sites).
   It is maintained through continuous requests of the PCE, both
   triggered by a baseline frequency as well as reported events that
   could impact connection.  Assuming a total of n data centers and
   other sites, this results in a connectivity matrix that is n x n.  It
   may be sparse, as some sites may not connect to others, and of
   course, a site does not connect to itself.  Each entry in the matrix
   represents a path between the sites, and each has relevant bandwidth,
   latency, etc. attributes.

   Here now the computation, whatever the algorithm, is much more
   efficient.  Connectivity information for any pair of data centers or



Veitch                    Expires June 3, 2017                 [Page 21]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


   possible endpoints is locally available.  There is no need to request
   information from another process, the PCE or other SDN controller.

10.6.  Multi-valued Connectivity Matrix

   Unfortunately, as described above, this solution still has
   limitations.  Only one path, perhaps selected based on greatest
   available bandwidth, is computed for each entry in the n x n
   connectivity matrix.  This path is not necessarily engineered to
   maximize or weight the path metrics in any way.  If a path between
   two datacenters needs a latency of 40 msec and the path in the
   connectivity matrix has latency of 80 msec, that option will be
   rejected.  This is a problem because a perfectly acceptable path with
   the needed bandwidth might exist along a different route.

   A possible solution here is to compute more than one path for each
   pair of sites, where each is based on a different set of criteria
   priorities.  These could include maximum bandwidth, minimum latency,
   fewest encapsulations (tunnels, tunnels in tunnels, packet layer to
   optical and back), fewest hops, fewest committed tunnels, least
   dynamic traffic patterns, etc.)  Others might include different
   balances of these values, and anti-affinity rules, e.g. do not share
   the same underlying optical paths, something important for
   identifying connectivity with backup paths.

   The result, therefore, is an n x n x m array, or simply an n x n
   array with each cell containing a list of path options, where the
   list length may vary for different sets of endpoints.  Each list
   entry (or cell in the m dimension for a 3 dimensional array) will
   represent a unique path supporting the connectivity between the two
   endpoints, where each has been computed for a different set of
   service priorities.

   There is still the concern that a network service might be requested
   for which a needed path's requirements (from a virtual link) are not
   satisfied by any entry in the connectivity matrix.  In other words,
   no connection with the relevant service requirements has been pre-
   computed.  The implication is that this could result in an
   unnecessary rejection of the requested network service.  To address
   this, it might be appropriate to include an option for the path or
   the orchestrator.  If the deplyment algorithm finds no satisfactory
   path in the matrix, the orchestrator could request directly to the
   PCE to see if it can find connectivity to meet its needs.

   Note: In the matrix, there may be endpoint pairs for which no path
   has been found.  The value in the matrix would be FAIL, or perhaps
   include something with a bit more useful information.  If a request




Veitch                    Expires June 3, 2017                 [Page 22]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


   fails because the requirements do not match any of the cached paths,
   it is an option to ask the PCE to re-check, or not.

   There are a number of ways the orchestrator could approach doing
   this.  The orchestrator might request the PCE to compute a point to
   point path that meets the service requirements, while itself, IN
   PARALLEL, continues to compute a different VNF placement and path
   solution.  If the PCE/controller finds a possible path to support the
   connection, or perhaps even if not, it would also make sense to add
   it to the connectivity matrix and change the path request options so
   that it is continuously computed and checked.

10.7.  Additional Optimization Options

   To this point the connectivity matrix has been described as n x n,
   with each possible endpoint, e.g. a data center or customer network,
   being represented.  In other words, there are n possible endpoints.
   For any pair of endpoints, if there is some connectivity between
   them, even if across multiple physical networks and domains, one or
   more paths between them could be continuously computed and stored.

   However, this is probably unnecessary.  Based on data center sites,
   physical and virtual connectivity, available functions, and customer
   interests, the sites that might connect with other sites are likely a
   significant subset of the full n x n possible connections.
   Therefore, it would make sense to weight the site-2-site connections.

   A very simple method is to compute paths only for site-to-site pairs
   that commonly connect as part of network services.  Other site-to-
   site paths would remain empty.  There are likely a number of ways to
   improve this based upon other factors, including learned behavior.
   One option is to initially compute a full n x n connectivity matrix,
   with mutiple paths for different priorities.  Subsequent refreshing
   of any connection depends upon the frequency of the use of that
   connection.  The frequency of updates would depend upon the frequency
   of the connection use.  Lower frequency connections will be assigned
   a lower weight.  The weight is refreshed whenever the connection is
   used, with the weight raised and the 'time last assigned' updated.
   On the other hand, another agent will execute periodically, and it
   will reduce each weight by a certain amount (though no lower than
   zero.)

   When a new service is to be placed, if the orchestrator finds a lower
   weight connection to be useful, it might choose to use it.  If the
   age is older than some configured threshold, it might ask the PCE to
   re-compute the path before it uses it.





Veitch                    Expires June 3, 2017                 [Page 23]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


10.8.  Cached Paths Over Multiple Sites

   In addition to the pre-computed site-2-site paths, another
   optimization step is to cache full or partial multi-site or multi
   data center paths.  Is is likely there will be a fixed number of
   network services and each with a fixed, or mostly fixed, order of
   network functions.  Even if some network services are dynamic in
   order, size and content (NFs), these will likely be a small minority,
   at the outset of NFV based network service delivery.  Therefore, it
   will be possible to identify a finite number of network services,
   including their VNF-FGs, i.e. the ordering of the NFs, and needed
   compute and network resources.  The frequencies and instantiation
   patterns of these services and their locations can be used to drive
   how often and how many cached instances should be computed, in order
   to ensure resources are available.  Computing for multiple links in a
   network service also provides the opportunity to sychronize the
   computations of available resources.  This should avoid the
   possibility of any connections in a network service unintentionally
   relying on the availability of bandwidth on the same physical link.

10.9.  Summary

   The purpose of this section has been to present options for computing
   optimized network service deployment that might drive requirements
   for a network SDN controller or PCE.  The organization of this
   section has been intended to build and make clear how the use of pre-
   computed and cached paths between the data center sites can benefit
   in the delivery of optimzed services.  It has described the creation
   and management of computing multiple paths for each pairwise set of
   data centers, based on different weights of factors, e.g. latency,
   bandwidth, etc.  It also has outlined how pre-computed full service
   paths might also work.  The result should be a greater likelihood of
   being able to deliver a service, as well as a significant reduction
   in the time to respond to service requests.

11.  Connectivity based on Potential vs. Actual Topologies

   Something missing here is how the orchestrator and PCE should
   consider 'potential connectivity' as part of the VNF placement and
   connectivity process.  For example, in the HPC use case, we know
   there will likely be a need for a high bandwidth low latency
   connection.  This is probably something that is not available in the
   connectivity matrix as described so far.  The matrix includes only
   information from the existing network topology configuration,
   including the configuration of existing tunnels, and performance
   metrics.





Veitch                    Expires June 3, 2017                 [Page 24]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


   This calls out that there is a need for an agent providing
   connectivity information, e.g.  PCE or SDN controller, to also
   present potential connectivity, should it be needed.  This is not a
   simply issue.  For example, updating or introducing a new underlying
   optical network circuit will affect the topology of the packet
   network running on top of it.  This means that existing paths between
   sites would no longer be valid.

   An orchestrator's deployment or placement algorithm should have the
   option to request this sort of 'potential' connectivity for any pair
   of sites, and the PCE or network controller that is computing these
   paths should be able to provide this.

   This functionality could be used for near term needs, perhaps
   dedicating that circuit for a single network service, such as the HPC
   service.  In the long term, other advantages might be realized.  For
   example, if the system is creating a large number of multi-hop
   connections between two data centers, the orchestrator or PCE may
   recognize this and propose a possible direct circuit connection to
   reduce costs and latency.  This is an area for more analysis.  It is
   something that will drive new information exchange between functional
   blocks, e.g. the PCE or SDN controller, via its NBI and perhaps SBI,
   if hierarchical architectures are used.

12.  Virtual Networks Equivalency

   To this point the description has been for a relatively simple
   network, with paths computed for different data center connections.
   Another perspective on this is to consider each data center and user
   endpoint as a node in the network, where these nodes are connected by
   one or more virtual links.  This is a virtual network then, where
   there is an abstraction layer between the physical and virtual
   networks.  Each entry in the connectivity matrix described above
   represents a link between any two data centers.  There may be more
   than one link, as these multiple links represent the multiple entries
   per matrix cell, with each created based on different priorities e.g.
   bandwidth, latency, etc.  In fact, the connectivity matrix described
   effectively describes this sort of virtual network.  As noted
   earlier, the connectivity matrix may be sparse.  Equivalently, the
   virtual network may not be show a link between every two nodes (data
   centers, etc.)

   One thing to consider is the possibility of multiple virtual
   networks, where each supports a different customer or some type of
   independent domain.  Multiple virtual networks (connectivity
   matrices) created, for each per customer or domain.  There might even
   be layering.  For example, a customer may use virtual networks (plus
   compute resources) from multiple providers, weave these together, and



Veitch                    Expires June 3, 2017                 [Page 25]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


   then offer services to its own customers.  This is equivalent to
   having specific connectivity matrices from each separate network and
   then combining these to create per customer connectivity matrices
   that combine information from the separate network matrices.

13.  Implications for the Network Controllers (SDN / PCE) and
     Orchestrators

   First, the network connectivity matrix (virtual network) must be
   continuously computed and the connection (link between sites)
   information passed to the NFV network service orchestrator as updates
   are generated.  The computations must consider topology, current
   resource allocations, measured utilization, analytics, e.g. trending,
   baselines, patterns, and policies.  Path computation must compute
   multiple paths concurrenty, for the same endpoints, but different
   priorities, policies, etc.  The computations are not for one set of
   service parameters, but to identify for a link the available
   resources (typically bandwidth) for meeting certain service
   requirements.

   A PCE path request should configure path re-computation and updates
   at a constant rate, e.g. every 5 minutes, as well as compute updates
   whenever an event triggers it.  Such an event might be a change in
   bandwidth, or perhaps latency, due to allocation over a path
   currently in the connectivity matrix, or congestion due to traffic
   volumes.  Each time the PCE computes a path it must do so with the
   latest information regarding connectivity, link state, reservations,
   and utilization and performance metrics.

   Note, unfortunatelypre-computation can create other problems.  For
   example, when computing a path, it is possible that the same physical
   (or virtual) link could be used in more than one NF-NF connection for
   a single network service.  A conflict might exist resulting in
   inadequate resources, and this would not be recognized.  For smaller
   services this might not be significant; however, for services that
   might require a lot of bandwidth, e.g. a large vCDN deployment, this
   might make a difference.

   Finally, for the cached multi-site and connection solution, this will
   require support for requesting and then computing the hop by hop
   paths, synchronized, and caching them such that a full soluton can be
   delivered quickly.

14.  Relationship to TEAS TE Topology and ACTN

   In the IETF there is a lot of relevant ongoing related to enhancing
   the PCE capabilities, the PCE Protocol, and the introduction of the
   Abstraction and Control of Transport Networks (ACTN) framework.  A



Veitch                    Expires June 3, 2017                 [Page 26]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


   number of concepts described here are really relevant to transport
   network services (including MPLS, segment routing, and technologies
   other than optical), whther supporting NFV network services or not.
   Some of these are described in the TEAS WG TE Topology, currently in
   development.  These include the description and definitions of
   network nodes, TE virtual links, and multiple layers of abstraction.
   PCE enhancements are defined to support this, and the ACTN framework
   address management and control from the service layer.

15.  Areas of Future Evaluation

   This is an early draft of this Internet draft.  Its intention has
   been to highlight, through use cases, the need for co-ordinated
   optimization of network and compute resources for NFV based network
   services delivery and to expand upon some solution options that lead
   to possible new requirements of the network controller (SDN / PCE.)
   There are a number of topics raised here, or which are related, that
   require further study.  These include:

   o  Testbed to evaluate effectiveness of pre-computation of
      connectivity and full network service paths.

   o  Evaluate requirements to support forecast or pre-sechedule network
      services.

   o  Determine any controller / PCE (PCEP) NBI / SBI messaging updates
      that might be needed

   o  Evaluate implications of non-ACID computations vs. deployments and
      methods to reduce risk.

   o  Centralized vs. Distributed computation of optimization

   o  Review work in other IETF and standardswork - ONF Transport, MEF,
      FORCES, ALTO, NFVRG, SDNRG, SFC WG, etc.

16.  IANA Considerations

   This memo includes no request to IANA.

   All drafts are required to have an IANA considerations section (see
   Guidelines for Writing an IANA Considerations Section in RFCs
   [RFC5226] for a guide).  If the draft does not require IANA to do
   anything, the section contains an explicit statement that this is the
   case (as above).  If there are no requirements for IANA, the section
   will be removed during conversion into an RFC by the RFC Editor.





Veitch                    Expires June 3, 2017                 [Page 27]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


17.  Security Considerations

   All drafts are required to have a security considerations section.
   See RFC 3552 [RFC3552] for a guide.

18.  References

18.1.  Normative References

   [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
              Requirement Levels", BCP 14, RFC 2119,
              DOI 10.17487/RFC2119, March 1997,
              <http://www.rfc-editor.org/info/rfc2119>.

18.2.  Informative References

   [I-D.ietf-pce-hierarchy-extensions]
              Zhang, F., Zhao, Q., Dios, O., Casellas, R., and D. King,
              "Extensions to Path Computation Element Communication
              Protocol (PCEP) for Hierarchical Path Computation Elements
              (PCE)", draft-ietf-pce-hierarchy-extensions-03 (work in
              progress), July 2016.

   [I-D.ietf-pce-pcep-yang]
              Dhody, D., Hardwick, J., Beeram, V., and j.
              jefftant@gmail.com, "A YANG Data Model for Path
              Computation Element Communications Protocol (PCEP)",
              draft-ietf-pce-pcep-yang-01 (work in progress), October
              2016.

   [I-D.ietf-pce-stateful-pce]
              Crabbe, E., Minei, I., Medved, J., and R. Varga, "PCEP
              Extensions for Stateful PCE", draft-ietf-pce-stateful-
              pce-17 (work in progress), November 2016.

   [I-D.ietf-teas-actn-framework]
              Ceccarelli, D. and Y. Lee, "Framework for Abstraction and
              Control of Traffic Engineered Networks", draft-ietf-teas-
              actn-framework-01 (work in progress), October 2016.

   [I-D.ietf-teas-pce-central-control]
              Farrel, A., Zhao, Q., Li, Z., and C. Zhou, "An
              Architecture for Use of PCE and PCEP in a Network with
              Central Control", draft-ietf-teas-pce-central-control-00
              (work in progress), September 2016.






Veitch                    Expires June 3, 2017                 [Page 28]


Internet-Draft   Integrated NFV and Network Optimization   November 2016


   [I-D.ietf-teas-yang-te]
              Saad, T., Gandhi, R., Liu, X., Beeram, V., Shah, H.,
              Bryskin, I., Chen, X., Jones, R., and B. Wen, "A YANG Data
              Model for Traffic Engineering Tunnels and Interfaces",
              draft-ietf-teas-yang-te-05 (work in progress), October
              2016.

   [I-D.ietf-teas-yang-te-topo]
              Liu, X., Bryskin, I., Beeram, V., Saad, T., Shah, H., and
              O. Dios, "YANG Data Model for TE Topologies", draft-ietf-
              teas-yang-te-topo-06 (work in progress), October 2016.

   [RFC3552]  Rescorla, E. and B. Korver, "Guidelines for Writing RFC
              Text on Security Considerations", BCP 72, RFC 3552,
              DOI 10.17487/RFC3552, July 2003,
              <http://www.rfc-editor.org/info/rfc3552>.

   [RFC5226]  Narten, T. and H. Alvestrand, "Guidelines for Writing an
              IANA Considerations Section in RFCs", BCP 26, RFC 5226,
              DOI 10.17487/RFC5226, May 2008,
              <http://www.rfc-editor.org/info/rfc5226>.

   [RFC5441]  Vasseur, JP., Ed., Zhang, R., Bitar, N., and JL. Le Roux,
              "A Backward-Recursive PCE-Based Computation (BRPC)
              Procedure to Compute Shortest Constrained Inter-Domain
              Traffic Engineering Label Switched Paths", RFC 5441,
              DOI 10.17487/RFC5441, April 2009,
              <http://www.rfc-editor.org/info/rfc5441>.

Author's Address

   Andrew Veitch (editor)
   Netcracker, Inc.
   95 Sawyer Road
   Waltham  02453
   US

   Email: andrew.veitch@netcracker.com













Veitch                    Expires June 3, 2017                 [Page 29]