INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

<draft-ietf-ipfc-fcmgmt-int-mib-07.txt>                   S. Blumenau
(expires Mar 17, 2002)                              (EMC Corporation)

          Fibre Channel Management Framework Integration MIB

Status of this Memo:

This document is an Internet-Draft and is in full conformance with
all provisions of Section 10 of RFC2026.

Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF), its areas, and its working groups.  Note that
other groups may also distribute working documents as
Internet-Drafts.

Internet-Drafts are draft documents valid for a maximum of six
months and may be updated, replaced, or obsoleted by other
documents at any time.  It is inappropriate to use Internet-Drafts
as reference material or to cite them other than as "work in
progress."

The list of current Internet-Drafts can be accessed at
http://www.ietf.org/ietf/1id-abstracts.txt

The list of Internet-Draft Shadow Directories can be accessed at
http://www.ietf.org/shadow.html.

Abstract:

The goal of this document is to fill in missing pieces necessary
to enable an enterprise class storage network. One of the more
important features of an enterprise class storage network is
management; this document gives a framework MIB that will provide
an integrated management environment for the enterprise customer.

An enterprise class storage network is comprised of elements
(i.e., hubs, switches, converters, gateways, and HBAs) that are
developed by many different vendors. The large number of vendors
that can exist in a storage network makes mangement a very hard
and complicated problem. The main goal of this document's MIB is
to enable interoperability among the various vendors involved in
the Fibre Channel marketplace.


Acknowledgements:

The following companies have contributed to the creation of this
specification:
        - Agilent Technologies
        - American Power Conversion
        - Ancor Communications
        - ArtStor AG
        - ATTO Technology, Inc.
        - BMC Software
        - Brocade Communications, Inc.

Blumenau                                                    [Page 01]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

        - Cambex
        - Chaparral Network Storage
        - CNT
        - Computer Associates
        - Connex Inc.
        - Crossroads
        - DISC Inc.
        - EMC Corporation
        - Emulex
        - Exabyte
        - Finisar
        - FORTEL
        - Fujitsu Siemens Computers
        - Gadzoox
        - Heroix Corporation
        - Hewlett-Packard Companys Enterprise Storage Solutions Division
        - Hewlett-Packard OpenView Business Unit
        - INRANGE Technologies Corporation
        - Integrix
        - Interphase Corporation
        - InterSAN
        - JMR Electronics
        - JNI
        - KOM, Inc.
        - Legato
        - Little Mountain Group, Inc.
        - McDATA Corporation
        - Nexsan Technologies Ltd.
        - Pathlight Technology
        - Prisa Networks, Inc.
        - Proactivenet
        - QLogic Corporation
        - Radiant Software, Inc.
        - SAN Valley Systems
        - Spectra Logic Corporation
        - Sterling Software
        - StorageNetworks, Inc.
        - StoreAge Networking Technologies
        - TD Systems Corporation
        - Troika Networks
        - VERITAS Software Corporation
        - Vixel Corporation
        - VMIC













Blumenau                                                    [Page 02]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

The MIB:

FCMGMT-MIB
-- Last edit date: Aug 19th, 2001

DEFINITIONS ::= BEGIN
  IMPORTS
    IpAddress,  TimeTicks, experimental
        FROM RFC1155-SMI
    OBJECT-TYPE
        FROM RFC-1212
    DisplayString
        FROM RFC1213-MIB
    TRAP-TYPE
        FROM RFC-1215;

----------------------------------------------------------------------
    --Textual conventions for this MIB

    FcNameId ::= OCTET STRING (SIZE(8))

    FcGlobalId ::= OCTET STRING (SIZE(16))

    FcAddressId ::= OCTET STRING (SIZE(3))

    FcEventSeverity  ::= INTEGER {
                unknown     (1),
                                emergency       (2),
                                alert           (3),
                                critical        (4),
                                error           (5),
                                warning         (6),
                                notify          (7),
                                info            (8),
                                debug           (9),
                                mark            (10)    -- All messages logged
            }

    FcUnitType ::= INTEGER {
                unknown(1),
                other(2), -- none of the following
                hub(3), -- passive connectivity unit
                        -- supporting loop protocol.
                switch(4), -- active connectivity unit
                        -- supporting multiple protocols.
                gateway(5), -- unit that converts not only
                        -- the interface but also encapsulates
                        -- the frame into another protocol. The
                        -- assumption is that there is always
                        -- two gateways connected together. For
                        -- example, FC <-> ATM.
                converter(6), -- unit that converts from one
                        -- interface to another. For
                        -- example, FC <-> SCSI.
                hba(7), -- host bus adapter

Blumenau                                                    [Page 03]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                proxy-agent(8), -- software proxy-agent
                storage-device(9), -- disk,cd,tape,etc
                host(10), -- host computer
                storage-subsystem(11), -- raid, library, etc
                module(12), -- subcomponent of a system
                swdriver(13), -- software driver
                storage-access-device(14), -- Provides storage management
                                          -- and access for hetergeneous
                                          -- hosts and heterogeneous devices.
                wdm(15), -- waveform division mutiplexer
                ups(16), -- uninterruptable power supply
                nas(17)  -- network attached storage (NFS/CIFS)
            }

----------------------------------------------------------------------
    fcmgmt    OBJECT IDENTIFIER ::= { experimental 94 }

    -- groups in fcmgmt

    connSet                    OBJECT IDENTIFIER ::= { fcmgmt 1 }
    trapReg                    OBJECT IDENTIFIER ::= { fcmgmt 2 }
    statSet                    OBJECT IDENTIFIER ::= { fcmgmt 4 }
    connUnitServiceSet         OBJECT IDENTIFIER ::= { fcmgmt 5 }
    connUnitServiceScalars     OBJECT IDENTIFIER ::= { connUnitServiceSet 1 }
    connUnitServiceTables      OBJECT IDENTIFIER ::= { connUnitServiceSet 2 }

    revisionNumber OBJECT-TYPE
        SYNTAX DisplayString (SIZE (4))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This is the revision number for this MIB. The
            format of the revision value is as follows
                (0) = high order major revision number
                (1) = low order major revision number
                (2) = high order minor revision number
                (3) = low order minor revision number
            The value will be stored as an ASCII value. The
            following is the current value of this object.
                (0) = '0'
                (1) = '4'
                (2) = '0'
                (3) = '0'
            This defines a revision of 04.00
            "
        ::= { fcmgmt 3 }

    -- the connectivity unit group

    -- Implementation of the group is mandatory for all systems.

    uNumber OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory

Blumenau                                                    [Page 04]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

        DESCRIPTION
            "The number of connectivity units present on this
            system (represented by this agent). May be a count
            of the boards in a chassis or the number of full boxes
            in a rack."
        DEFVAL { 1 }
        ::= { connSet 1 }

    systemURL OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The top-level URL of the system. If it does not exist
            the value is empty string. The URL format is
            implementation dependant and can have keywords embedded
            that are preceeded by a percent sign (eg, %USER).
            The following are the defined keywords that will
            be recognized and replaced with data during a launch.
                USER        - replace with username
                PASSWORD    - replace with password
                GLOBALID    - replace with globalid
                SERIALNO    - replace with serial number
            A management application will read this object from the
            MIB, provide values for any of the keywords listed above
            that are present in the string, and then use the URL to
            invoke or launch the program referenced.
            If write is not supported, then return invalid.
            This value will be retained across boots."
        DEFVAL { "" }
        ::= { connSet 2 }

    statusChangeTime OBJECT-TYPE
        SYNTAX TimeTicks
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "The sysuptime timestamp in centiseconds at which
            the last status change occurred for any members of
            the set."
        ::= { connSet 3 }

    configurationChangeTime OBJECT-TYPE
        SYNTAX TimeTicks
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "The sysuptime timestamp in centiseconds at which
            the last configuration change occurred for any
            members of the set. This represents a union of change
            information for connUnitConfigurationChangeTime."
        ::= { connSet 4 }

    connUnitTableChangeTime OBJECT-TYPE
        SYNTAX TimeTicks

Blumenau                                                    [Page 05]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "The sysuptime timestamp in centiseconds at which
            the connUnitTable was updated (an entry was either
            added or deleted."
        ::= { connSet 5 }

    -- The Connectivity table contains general information on the
    -- system's units.
    connUnitTable OBJECT-TYPE
        SYNTAX SEQUENCE OF ConnUnitEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "The connectivity table contains general information
             on the system's units. This is the list of units under
             a single SNMP agent. The number of entries is given by
             the value of uNumber. It is 1 for stand-alone system."
        ::= { connSet 6 }

    connUnitEntry OBJECT-TYPE
        SYNTAX ConnUnitEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A connectivity unit entry containing objects for a
             particular unit."
        INDEX { connUnitId }
        ::= { connUnitTable 1 }

        ConnUnitEntry ::=
            SEQUENCE {
                connUnitId
                    FcGlobalId,
                connUnitGlobalId
                    FcGlobalId,
                connUnitType
                    FcUnitType,
                connUnitNumports
                    INTEGER,
                connUnitState
                    INTEGER,
                connUnitStatus
                    INTEGER,
                connUnitProduct
                    DisplayString,
                connUnitSn
                    DisplayString,
                connUnitUpTime
                    TimeTicks,
                connUnitUrl
                    DisplayString,
                connUnitDomainId
                    OCTET STRING,

Blumenau                                                    [Page 06]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                connUnitProxyMaster
                    INTEGER,
                connUnitPrincipal
                    INTEGER,
                connUnitNumSensors
                    INTEGER,
                connUnitStatusChangeTime
                    TimeTicks,
                connUnitConfigurationChangeTime
                    TimeTicks,
                connUnitNumRevs
                    INTEGER,
                connUnitNumZones
                    INTEGER,
                connUnitModuleId
                    FcGlobalId,
                connUnitName
                    DisplayString,
                connUnitInfo
                    DisplayString,
                connUnitControl
                    INTEGER,
                connUnitContact
                    DisplayString,
                connUnitLocation
                    DisplayString,
                connUnitEventFilter
                    FcEventSeverity,
                connUnitNumEvents
                    INTEGER,
                connUnitMaxEvents
                    INTEGER,
                connUnitEventCurrID
                    INTEGER,
                connUnitFabricID
                    FcGlobalId,
                connUnitNumLinks
                    INTEGER,
                connUnitVendorId
                    DisplayString
            }

        connUnitId OBJECT-TYPE
            SYNTAX FcGlobalId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                        "The unique identification for this connectivity unit
                        among those within this proxy domain.
                        The value MUST be unique within the proxy domain
                        because it is the index variable for connUnitTable.
                        The value assigned to a given conectivity unit
                        SHOULD be persistent across agent and unit resets.
                        It SHOULD be the same as connUnitGlobalId
                        if connUnitGlobalId is known and stable."
            ::= { connUnitEntry 1 }
Blumenau                                                    [Page 07]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

        connUnitGlobalId OBJECT-TYPE
            SYNTAX FcGlobalId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                        "An optional global-scope identifier for this connectivity unit.
                        It MUST be a WWN for this connectivity unit
                        or 16 octets of value zero.
                        WWN formats requiring fewer than 16 octets
                        MUST be extended to 16 octets with trailing zero octets,
                        Left justified, zero filled,
                        If a WWN is used for connUnitId,
                        the same WWN MUST be used for connUnitGlobalId.
                        When a non-zero value is provided,
                        it SHOULD be persistent across agent and unit resets.
                        It SHOULD be globally unique.
                        It SHOULD be one of these FC-PH/PH3 formats:
                                IEEE (NAA=1)
                                IEEE Extended (NAA=2)
                                IEEE Registered (NAA=5).
                                IEEE Registered extended (NAA=6).

                        Use of the IEEE formats allows any IEEE-registered vendor
                        to assure global uniqueness independently.
                        The following are some references on IEEE WWN formats:
           http://standards.ieee.org/regauth/oui/tutorials/fibreformat.html
           http://standards.ieee.org/regauth/oui/tutorials/fibrecomp_id.html

                        If one or more WWNs are associated with the connUnit
                        via other management methods,
                        one of them SHOULD be used for connUnitGlobalId.
                        If there is not a WWN assigned specifically to the connUnit,
                        there is some merit, though not a requirement,
                        to using a WWN assigned to (one of)
                        its permanently attached FC/LAN interface(s).
                        This can not risk uniqueness, though.
                        As a counterexample, if your
                        agent runs in a host and the host has an HBA,
                        it is quite possible that agent, host, and HBA
                        will all be distinct connUnits, so the host
                        and agent can not use the WWN of the HBA.
                        Another example:
                        If your hub has a built-in Ethernet port, it
                        might be reasonable for the hub to use its MAC
                        address (prefixed with the appropriate
                        NAA) as its connUnitId. But if the
                        Ethernet were a replaceable PCCard, the hub
                        should have an independent ID."
            ::= { connUnitEntry 2 }

        connUnitType OBJECT-TYPE
            SYNTAX FcUnitType
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION

Blumenau                                                    [Page 08]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                "The type of this connectivity unit."
            ::= { connUnitEntry 3 }


        connUnitNumports OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of physical ports in the connectivity unit
                (internal/embedded, external)."
            ::= { connUnitEntry 4 }

        connUnitState OBJECT-TYPE
            SYNTAX INTEGER {
                unknown(1),
                online(2), -- available for meaningful work
                offline(3) -- unavailable for meaningful work, for
                           -- example in self-test mode, configuration, etc.
            }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This object reports the overall state of the
                 connectivity unit.  The meaning of all values
                 is essentially self-explanatory.  Any of these
                 values may occur with any of the ConnUnitStatus
                 values."
            ::= { connUnitEntry 5 }

        connUnitStatus OBJECT-TYPE
            SYNTAX INTEGER {
                unknown(1),
                unused(2), -- cannot report status
                ok(3), -- available for meaningful work
                warning(4), -- something needs attention
                failed(5) -- something has failed
            }
            ACCESS read-only
            STATUS mandatory

            DESCRIPTION
                "Overall status of the connectivity unit. The goal of this
                 object is to be the single poll point to check the status
                 of the connunit. If there is any other component that has
                 warning, then this should be set to warning, etc. Any of
                 these values may occur with any of the ConnUnitState
                 values."
            ::= { connUnitEntry 6 }

        connUnitProduct OBJECT-TYPE
            SYNTAX DisplayString (SIZE (0..79))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION

Blumenau                                                    [Page 09]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                "The connectivity unit vendor's product
                model name."
            ::= { connUnitEntry 7 }

        connUnitSn OBJECT-TYPE
            SYNTAX DisplayString (SIZE (0..79))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The serial number for this connectivity unit."
            ::= { connUnitEntry 8 }

        connUnitUpTime OBJECT-TYPE
            SYNTAX TimeTicks
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The number of centiseconds since the
                last unit initialization."
            ::= { connUnitEntry 9 }

        connUnitUrl OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "URL to launch a management application,
                if applicable. Otherwise empty string.
                In a standalone unit, this would be the
                same as the top-level URL. This has the same
                definition as systemURL for keywords.
                If write is not supported, then return invalid.
                This value will be retained across boots."
            ::= { connUnitEntry 10 }

        connUnitDomainId OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE(3))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "24 bit Fibre Channel address ID of this
                connectivity unit, right justified with leading
                zero's if required. This should be set to the
                Fibre Channel address ID or if it is a switch
                it would be set to the Domain Controller address.
                If this value is not applicable,
                return all bits set to 1."
            ::= { connUnitEntry 11 }

        connUnitProxyMaster OBJECT-TYPE
            SYNTAX INTEGER {
                unknown(1),
                no(2),
                yes(3)
            }

Blumenau                                                    [Page 10]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "A value of 'yes' means this is the proxy master
                unit for a set of managed units. For example,
                this could be the only unit with a management
                card in it for a set of units. A standalone unit
                should return 'yes' for this object."
            ::= { connUnitEntry 12 }

        connUnitPrincipal OBJECT-TYPE
            SYNTAX INTEGER {
                unknown(1),
                no(2),
                yes(3)
            }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Whether this connectivity unit is the principal unit
                within the group of fabric elements. If this value
                is not applicable, return unknown."
            ::= { connUnitEntry 13 }

        connUnitNumSensors OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of sensors in the connUnitSensorTable."
            ::= { connUnitEntry 14 }

        connUnitStatusChangeTime OBJECT-TYPE
            SYNTAX TimeTicks
            ACCESS read-only
            STATUS obsolete
            DESCRIPTION
                "The sysuptime timestamp in centiseconds
                at which the last status change occurred."
            ::= { connUnitEntry 15 }

        connUnitConfigurationChangeTime OBJECT-TYPE
            SYNTAX TimeTicks
            ACCESS read-only
            STATUS obsolete
            DESCRIPTION
                "The sysuptime timestamp in centiseconds
                at which the last configuration change
                occurred."
            ::= { connUnitEntry 16 }

        connUnitNumRevs OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory

Blumenau                                                    [Page 11]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

            DESCRIPTION
                "The number of revisions in the connUnitRevsTable."
            DEFVAL { 1 }
            ::= { connUnitEntry 17 }

        connUnitNumZones OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS obsolete
            DESCRIPTION
                "Number of zones defined in connUnitZoneTable."
            ::= { connUnitEntry 18 }

        connUnitModuleId OBJECT-TYPE
            SYNTAX FcGlobalId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is a unique id, persistent between boots,
                that can be used to group a set of connUnits
                together into a module. The intended use would
                be to create a connUnit with a connUnitType of
                'module' to represent a physical or logical
                group of connectivity units. Then the value
                of the group would be set to the value of
                connUnitId for this 'container' connUnit.
                connUnitModuleId should be zeros if this
                connUnit is not part of a module."
            ::= { connUnitEntry 19 }

        connUnitName OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..79))
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "A display string containing a name for this
                connectivity unit.  This object value should be
                persistent between boots."
            ::= { connUnitEntry 20 }

        connUnitInfo OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "A display string containing information
                about this connectivity unit. This object value
                should be persistent between boots."
            ::= { connUnitEntry 21 }

        connUnitControl OBJECT-TYPE
            SYNTAX INTEGER {
                unknown(1),
                invalid(2),
                resetConnUnitColdStart(3),

Blumenau                                                    [Page 12]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                resetConnUnitWarmStart(4),
                offlineConnUnit(5),
                onlineConnUnit(6)
            }
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This object is used to control the addressed
                connUnit.

                NOTE: 'Cold Start' and 'Warm Start'
                are as defined in MIB II and are not meant
                to be a factory reset.

                resetConnUnitColdStart:
                    the addressed unit performs
                    a 'Cold Start' reset.

                resetConnUnitWarmStart:
                    the addressed unit performs
                    a 'Warm Start' reset.

                offlineConnUnit:
                    the addressed unit puts itself into
                    an implementation dependant 'offline' state.
                    In general,if a unit is in an offline state,
                    it cannot be used to perform meaningful
                    Fibre Channel work.

                onlineConnUnit:
                    the addressed unit puts itself into an
                    implementation dependant 'online' state.
                    In general, if a unit is in an online state,
                    it is capable of performing meaningful
                    Fibre Channel work.

                NOTE: Each implementation may chose not to allow
                any or all of these values on a SET. "

            ::= { connUnitEntry 22 }

        connUnitContact OBJECT-TYPE
            SYNTAX DisplayString (SIZE (0..79))
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "Contact information for this connectivity
                unit. Persistent across boots."
            ::= { connUnitEntry 23 }

        connUnitLocation OBJECT-TYPE
            SYNTAX DisplayString (SIZE (0..79))
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION

Blumenau                                                    [Page 13]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                "Location information for this connectivity
                unit.Persistent across boots."
            ::= { connUnitEntry 24 }

        connUnitEventFilter OBJECT-TYPE
            SYNTAX FcEventSeverity
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This value defines the event severity
                that will be logged by this connectivity unit.
                All events of severity less than or equal to
                connUnitEventFilter are logged in connUnitEventTable.
                Persistent across boots."
            ::= { connUnitEntry 25 }

        connUnitNumEvents OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of events currently in the
                connUnitEventTable."
            ::= { connUnitEntry 26 }

        connUnitMaxEvents OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Max number of events that can be defined
                in connUnitEventTable."
            ::= { connUnitEntry 27 }

        connUnitEventCurrID OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The last used event id (connUnitEventIndex)."
            ::= { connUnitEntry 28 }

        connUnitFabricID OBJECT-TYPE
            SYNTAX FcGlobalId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "A globally unique value to identify the fabric that this
                ConnUnit belongs to, otherwise empty string. This would
                typically be equal to the connUnitGlobalID of the
                primary switch in a Fibre Channel fabric."
                ::= { connUnitEntry 29 }

        connUnitNumLinks OBJECT-TYPE
            SYNTAX INTEGER

Blumenau                                                    [Page 14]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The number of links in the link table."
            ::= { connUnitEntry 30 }

        connUnitVendorId OBJECT-TYPE
            SYNTAX DisplayString (SIZE (0..79))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The connectivity unit vendor's name."
            ::= { connUnitEntry 31 }

------------------------------------------------------------------
-- The Table of revisions for hardware and software elements.

    connUnitRevsTable OBJECT-TYPE
        SYNTAX SEQUENCE OF ConnUnitRevsEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Table of the revisions supported by
            connectivity units managed by this agent."
        ::= { connSet 7 }

    connUnitRevsEntry OBJECT-TYPE
        SYNTAX ConnUnitRevsEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            ""
        INDEX { connUnitRevsUnitId,
            connUnitRevsIndex }
            ::= { connUnitRevsTable 1 }

        ConnUnitRevsEntry ::=
            SEQUENCE {
                connUnitRevsUnitId
                    FcGlobalId,
                connUnitRevsIndex
                    INTEGER,
                connUnitRevsRevId
                    DisplayString,
                connUnitRevsDescription
                    DisplayString            }

        connUnitRevsUnitId OBJECT-TYPE
            SYNTAX FcGlobalId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The connUnitId of the connectivity unit
                that contains this revision table."
            ::= { connUnitRevsEntry 1 }

Blumenau                                                    [Page 15]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

        connUnitRevsIndex OBJECT-TYPE
            SYNTAX INTEGER (1..2147483647)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "A unique value among all connUnitRevsEntrys
                with the same value of connUnitRevsUnitId,
                in the range between 1 and
                connUnitNumRevs[connUnitRevsUnitId]."
            ::= { connUnitRevsEntry 2 }

        connUnitRevsRevId OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "A vendor-specific string identifying a
                revision of a component of the connUnit
                indexed by connUnitRevsUnitId."
            ::= { connUnitRevsEntry 3 }

        connUnitRevsDescription OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Description of a component to which the revision
                corresponds."
            ::= { connUnitRevsEntry 4 }

-----------------------------------------------------------------------
--    The Sensor table

    connUnitSensorTable OBJECT-TYPE
        SYNTAX SEQUENCE OF ConnUnitSensorEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Table of the sensors supported by each
            connectivity unit managed by this agent."
        ::= { connSet 8 }

    connUnitSensorEntry OBJECT-TYPE
        SYNTAX ConnUnitSensorEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Each entry contains the information for a
            specific sensor."
        INDEX { connUnitSensorUnitId,
            connUnitSensorIndex }
            ::= { connUnitSensorTable 1 }

        ConnUnitSensorEntry ::=
            SEQUENCE {

Blumenau                                                    [Page 16]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                connUnitSensorUnitId
                   FcGlobalId,
                connUnitSensorIndex
                    INTEGER (1..2147483647),
                connUnitSensorName
                    DisplayString,
                connUnitSensorStatus
                    INTEGER,
                connUnitSensorInfo
                    DisplayString,
                connUnitSensorMessage
                    DisplayString,
                connUnitSensorType
                    INTEGER,
                connUnitSensorCharacteristic
                    INTEGER
            }

        connUnitSensorUnitId OBJECT-TYPE
            SYNTAX FcGlobalId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The connUnitId of the connectivity unit
                that contains this sensor table."
            ::= { connUnitSensorEntry 1 }

        connUnitSensorIndex OBJECT-TYPE
            SYNTAX INTEGER (1..2147483647)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "A unique value among all connUnitSensorEntrys
                with the same value of connUnitSensorUnitId,
                in the range between 1 and
                connUnitNumSensor[connUnitSensorUnitId]."
            ::= { connUnitSensorEntry 2}

        connUnitSensorName OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "A textual identification of the sensor
                 intended primarily for operator use."
            ::= { connUnitSensorEntry 3 }

        connUnitSensorStatus OBJECT-TYPE
            SYNTAX INTEGER {
                unknown(1),
                other(2), -- the sensor indicates other than ok,
                          -- warning or failure.
                ok(3),      -- the sensor indicates ok
                warning(4), -- the sensor indicates a warning
                failed(5)   -- the sensor indicates failure

Blumenau                                                    [Page 17]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

            }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The status indicated by the sensor."
            ::= { connUnitSensorEntry 4 }

        connUnitSensorInfo OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Miscellaneous static info about the sensor
                such as its serial number."
            ::= { connUnitSensorEntry 5 }

        connUnitSensorMessage OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This describes the status of the sensor
                as a message. It may also provide more
                resolution on the sensor indication, for
                example 'Cover temperature 1503K, above
                nominal operating range'"
            ::= { connUnitSensorEntry 6 }

        connUnitSensorType OBJECT-TYPE
            SYNTAX INTEGER {
                unknown(1),
                other(2),
                battery(3),
                fan(4),
                power-supply(5),
                transmitter(6),
                enclosure(7),
                board(8),
                receiver(9)
            }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The type of component being monitored by this
                sensor."
            ::= { connUnitSensorEntry 7 }

        connUnitSensorCharacteristic OBJECT-TYPE
            SYNTAX INTEGER {
                unknown(1),
                other(2),
                temperature(3),
                pressure(4),
                emf(5),
                currentValue(6), -- current is a keyword

Blumenau                                                    [Page 18]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                airflow(7),
                frequency(8),
                power(9),
                door(10)
            }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The characteristics being monitored by this
                sensor."
            ::= { connUnitSensorEntry 8 }

-----------------------------------------------------------------------
--    The port table

    connUnitPortTable OBJECT-TYPE
        SYNTAX SEQUENCE OF ConnUnitPortEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Generic information on ports for a specific
            connUnit."
        ::= { connSet 10 }

    connUnitPortEntry OBJECT-TYPE
        SYNTAX ConnUnitPortEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Each entry contains the information for
            a specific port."
        INDEX { connUnitPortUnitId,
            connUnitPortIndex }
            ::= { connUnitPortTable 1 }

        ConnUnitPortEntry ::=
            SEQUENCE {
                connUnitPortUnitId
                    FcGlobalId,
                connUnitPortIndex
                    INTEGER,
                connUnitPortType
                    INTEGER,
                connUnitPortFCClassCap
                    OCTET STRING,
                connUnitPortFCClassOp
                    OCTET STRING,
                connUnitPortState
                    INTEGER,
                connUnitPortStatus
                    INTEGER,
                connUnitPortTransmitterType
                    INTEGER,
                connUnitPortModuleType
                    INTEGER,

Blumenau                                                    [Page 19]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                connUnitPortWwn
                    FcGlobalId,
                connUnitPortFCId
                    FcAddressId,
                connUnitPortSn
                    DisplayString,
                connUnitPortRevision
                    DisplayString,
                connUnitPortVendor
                    DisplayString,
                connUnitPortSpeed
                    INTEGER,
                connUnitPortControl
                    INTEGER,
                connUnitPortName
                    DisplayString,
                connUnitPortPhysicalNumber
                    INTEGER,
                connUnitPortStatObject
                    OBJECT IDENTIFIER,
                connUnitPortProtocolCap
                    OCTET STRING,
                connUnitPortProtocolOp
                    OCTET STRING,
                connUnitPortNodeWwn
                    FcNameId,
                connUnitPortHWState
                    INTEGER
            }

        connUnitPortUnitId OBJECT-TYPE
            SYNTAX FcGlobalId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The connUnitId of the connectivity unit
                that contains this port."
            ::= { connUnitPortEntry 1 }

        connUnitPortIndex OBJECT-TYPE
            SYNTAX INTEGER (1..2147483647)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "A unique value among all connUnitPortEntrys
                on this connectivity unit, between 1 and
                connUnitNumPort[connUnitPortUnitId]."
            ::= { connUnitPortEntry 2 }

        connUnitPortType OBJECT-TYPE
            SYNTAX INTEGER {
                unknown       (1),
                other         (2),
                not-present   (3),
                hub-port      (4),

Blumenau                                                    [Page 20]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                n-port        (5),  -- end port for fabric
                nl-port       (6),  -- end port for loop
                fl-port       (7),  -- public loop
                f-port        (8),  -- fabric port
                e-port        (9),  -- fabric expansion port
                g-port        (10), -- generic fabric port
                domain-ctl    (11), -- domain controller
                hub-controller(12),
                scsi          (13), -- parallel SCSI port
                escon         (14),
                lan           (15),
                wan           (16),
                ac            (17), -- AC power line
                dc            (18), -- DC power line
                ssa           (19), -- serial storage architecture
                wdm           (20), -- optical wave division multiplex
                ib            (21), -- Infiniband
                ipstore       (22) -- IP storage
            }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The port type."
            ::= { connUnitPortEntry 3 }

        connUnitPortFCClassCap OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (2))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Bit mask that specifies the classes
                of service capability of this port. If this is not
                applicable, return all bits set to zero.

                The bits have
                the following definition:
                    unknown      - 0
                    class-f      - 1
                    class-one    - 2
                    class-two    - 4
                    class-three  - 8
                    class-four   - 16
                    class-five   - 32
                    class-six    - 64"
            ::= { connUnitPortEntry 4 }

        connUnitPortFCClassOp OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (2))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Bit mask that specifies the classes
                of service that are currently operational.
                If this is not applicable, return all bits
                set to zero.  This object has the same

Blumenau                                                    [Page 21]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                definition as connUnitPortFCClassCap"
            ::= { connUnitPortEntry 5 }

        connUnitPortState OBJECT-TYPE
            SYNTAX INTEGER {
                unknown(1),
                online(2), -- available for meaningful work
                offline(3), -- not available for meaningful work
                bypassed(4), -- no longer used (4/12/00)
                diagnostics(5)
            }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The user selected state of the port hardware."
           ::= { connUnitPortEntry 6 }

        connUnitPortStatus OBJECT-TYPE
            SYNTAX INTEGER {
                unknown           (1),
                unused            (2), -- device cannot report this status
                ready             (3), -- FCAL Loop or FCPH Link reset protocol
                                       -- initialization has completed
                warning           (4), -- do not use (4/12/00)
                failure           (5), -- do not use (4/12/00)
                notparticipating  (6), -- loop notparticipating and does not
                                       -- have a loop address
                initializing      (7), -- protocol is proceeding
                bypass            (8), -- do not use (4/12/00)
                ols               (9), -- FCP offline status
                other             (10) -- status not described above
            }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "An overall protocol status for the
                port. This value of connUnitPortState is not
                online, then this is reported Unknown."
            ::= { connUnitPortEntry 7 }

        connUnitPortTransmitterType OBJECT-TYPE
            SYNTAX INTEGER {
                unknown(1),
                other(2),
                unused(3),
                shortwave(4),
                longwave(5),
                copper(6),
                scsi(7),
                longwaveNoOFC(8),
                shortwaveNoOFC(9),
                longwaveLED(10),
                ssa(11)
             }
            ACCESS read-only

Blumenau                                                    [Page 22]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

            STATUS mandatory
            DESCRIPTION
                "The technology of the port transceiver."
            ::= { connUnitPortEntry 8 }

        connUnitPortModuleType OBJECT-TYPE
            SYNTAX INTEGER {
                unknown(1),
                other(2),
                gbic(3),
                embedded(4), -- fixed, ie, oneXnine
                glm(5),
                gbicSerialId(6),
                gbicNoSerialId(7),
                gbicNotInstalled(8),
                smallFormFactor(9) -- this is generically a small form factor
                                   -- connector.
            }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The module type of the port connector."
            ::= { connUnitPortEntry 9 }

        connUnitPortWwn OBJECT-TYPE
            SYNTAX FcGlobalId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The World Wide Name of the port
                if applicable, otherwise all zeros."
             ::= { connUnitPortEntry 10 }

        connUnitPortFCId OBJECT-TYPE
            SYNTAX FcAddressId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is the assigned Fibre Channel ID of
                this port.  This value is expected to be
                a Big Endian value of 24 bits. If this is
                loop, then it is the ALPA that is connected.
                If this is an eport, then it will only
                contain the domain ID left justified, zero
                filled. If this port does not have a Fibre
                Channel address, return all bits set to 1."
            ::= { connUnitPortEntry 11 }

        connUnitPortSn OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..79))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The serial number of the unit (e.g., for
                a GBIC). If this is not applicable, return

Blumenau                                                    [Page 23]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                empty string."
            ::= { connUnitPortEntry 12 }

        connUnitPortRevision OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..79))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The port revision (e.g., for a GBIC)."
            ::= { connUnitPortEntry 13 }

        connUnitPortVendor OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..79))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The port vendor (e.g., for a GBIC)."
            ::= { connUnitPortEntry 14 }

        connUnitPortSpeed OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The speed of the port in kilobytes per
                second."
            ::= { connUnitPortEntry 15 }

        connUnitPortControl OBJECT-TYPE
            SYNTAX INTEGER {
                unknown(1),
                invalid(2),
                resetConnUnitPort(3),
                bypassConnUnitPort(4),
                unbypassConnUnitPort(5),
                offlineConnUnitPort(6),
                onlineConnUnitPort(7),
                resetConnUnitPortCounters(8)
            }
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This object is used to control the addressed
                connUnit's port. Valid commands are:

                resetConnUnitPort: If the addressed connUnit
                    allows this operation to be performed to this
                    port, the addressed port performs a
                    vendor-specific 'reset' operation. Examples of
                    these operations are: the Link Reset protocol,
                    the Loop Initialization protocol, or a
                    resynchronization occurring between the
                    transceiver in the addressed port to the
                    transceiver that the port is connected to.


Blumenau                                                    [Page 24]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                bypassConnUnitPort: If the addressed connUnit
                    allows this operation to be performed to this
                    port, the addressed port performs a
                    vendor-specific 'bypass' operation. Examples of
                    these operations are:
                    transitioning from online to offline, a
                    request(NON-PARTICIPATING) command to the
                    Loop Port state machine, or removal of the
                    port from an arbitrated loop by a hub.

                unbypassConnUnitPort: If the addressed connUnit
                    allows this operation to be performed to this
                    port, the addressed port performs a
                    vendor-specific 'unbypass' operation. Examples
                    of these operations are:
                    the Link Failure protocol, a
                    request(PARTICIPATING) command to the
                    Loop Port state machine, or addition of the
                    port to an arbitrated loop by a hub.

                offlineConnUnitPort: If the addressed connUnit
                    allows this operation to be performed to this
                    port, the addressed port performs a
                    vendor-specific 'offline' operation. Examples
                    of these operations are:
                    disabling a port's transceiver, the Link
                    Failure protocol, request(NON-PARTICIPATING)
                    command to the Loop Port state machine, or
                    removal of the port from an arbitrated loop
                    by a hub.

                onlineConnUnitPort: If the addressed connUnit
                    allows this operation to be performed to this
                    port, the addressed port performs a
                    vendor-specific 'online' operation. Examples
                    of these operations are:
                    enabling a port's transceiver, the Link
                    Failure protocol, request(PARTICIPATING)
                    command to the Loop Port state machine, or
                    addition of the port from an arbitrated loop
                    by a hub.

                resetConnUnitPortCounters: If the addressed connUnit
                    allows this operation to be performed to this
                    port, the addressed port statistics table counters
                    will be set to zero.

                NOTE: Each implementation may chose not to allow
                any or all of these values on a SET. On a read, if
                you do not support write, then return invalid. Otherwise
                return the last control operation attempted."

            ::= { connUnitPortEntry 16 }

        connUnitPortName OBJECT-TYPE

Blumenau                                                    [Page 25]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

            SYNTAX DisplayString
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "A user-defined name for this port. This means that up to
                 DisplayString characters may be supported. If less than,
                 then the name will be truncated in the connunit."
            ::= { connUnitPortEntry 17 }

        connUnitPortPhysicalNumber OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is the internal port number this
                port is known by. In many implementations,
                this should be the same as connUnitPortIndex.
                Some implementations may have an internal port
                representation not compatible with the rules
                for table indeces.  In that case, provide the
                internal representation of this port in this
                object.  This value may also be used in the
                connUnitLinkPortNumberX or connUnitLinkPortNumberY
                objects of the connUnitLinkTable."
            ::= { connUnitPortEntry 18 }

        connUnitPortStatObject OBJECT-TYPE
            SYNTAX OBJECT IDENTIFIER
            ACCESS read-only
            STATUS deprecated
            DESCRIPTION
                "This contains the OID of the first object of the
                table that contains the statistics for this particular
                port. If this has a value of zero, then there are no
                statistics available for this port. The port type
                information will help identify the statistics objects
                that will be found in the table."
            ::= { connUnitPortEntry 19 }

        connUnitPortProtocolCap OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (2))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Bit mask that specifies the driver level
                protocol capability of this port. If this is not
                applicable, return all bits set to zero.

                The bits have
                the following definition:
                    unknown      - 0
                    Loop         - 1
                    Fabric       - 2
                    SCSI         - 4
                    TCP/IP       - 8

Blumenau                                                    [Page 26]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                    VI           - 16
                    FICON        - 32"
            ::= { connUnitPortEntry 20 }

        connUnitPortProtocolOp OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (2))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Bit mask that specifies the driver level
                protocol(s) that are currently operational.
                If this is not applicable, return all bits
                set to zero.  This object has the same
                definition as connUnitPortProtocolCap"
            ::= { connUnitPortEntry 21 }

        connUnitPortNodeWwn OBJECT-TYPE
            SYNTAX FcNameId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The Node World Wide Name of the port
                if applicable, otherwise all zeros.
                This should have the same value for a
                group of related ports. The container is
                defined as the largest physical unit.
                For example, all ports on HBAs on a host
                will have the same Node WWN. All ports on
                the same storage subsystem will have the
                same Node WWN."
             ::= { connUnitPortEntry 22 }

        connUnitPortHWState OBJECT-TYPE
            SYNTAX INTEGER {
                unknown     (1),
                failed      (2), -- port failed diagnostics
                bypassed    (3),  -- FCAL bypass, loop only
                active      (4), -- connected to a device
                loopback    (5), -- Port in ext loopback
                txfault     (6), -- Transmitter fault
                noMedia     (7), -- media not installed
                linkDown    (8)  -- waiting for activity (rx sync)
            }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The hardware detected state of the port."
           ::= { connUnitPortEntry 23 }

-----------------------------------------------------------------------
-- event group

    connUnitEventTable OBJECT-TYPE
        SYNTAX SEQUENCE OF ConnUnitEventEntry
        ACCESS not-accessible

Blumenau                                                    [Page 27]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

        STATUS mandatory
        DESCRIPTION
            "The table of connectivity unit events. Errors,
            warnings, and information should be reported
            in this table."
        ::= { connSet 11 }

    connUnitEventEntry OBJECT-TYPE
        SYNTAX ConnUnitEventEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Each entry contains information on
            a specific event for the given
            connectivity unit."
        INDEX { connUnitEventUnitId, connUnitEventIndex }
        ::= { connUnitEventTable 1 }

        ConnUnitEventEntry ::=
            SEQUENCE {
                connUnitEventUnitId
                    FcGlobalId,
                connUnitEventIndex
                    INTEGER (1..2147483647),
                connUnitEventId
                    INTEGER,
                connUnitREventTime
                    DisplayString,
                connUnitSEventTime
                    TimeTicks,
                connUnitEventSeverity
                    FcEventSeverity,
                connUnitEventType
                    INTEGER,
                connUnitEventObject
                    OBJECT IDENTIFIER,
                connUnitEventDescr
                    DisplayString
            }

        connUnitEventUnitId OBJECT-TYPE
            SYNTAX FcGlobalId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The connUnitId of the connectivity unit
                that contains this event table."
            ::= { connUnitEventEntry 1 }

        connUnitEventIndex OBJECT-TYPE
            SYNTAX INTEGER (1..2147483647)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Each connectivity unit has its own event buffer.

Blumenau                                                    [Page 28]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                As it wraps, it may write over previous events.
                This object is an index into the buffer.
                It is recommended that this table be read using
                'getNext's to retrieve the initial table.
                The management application should read the
                event table at periodic intervals and then
                determine if any new entries were added by
                comparing the last known index value with the
                current highest index value. The management
                application should then update its copy of
                the event table. If the read interval
                is too long, it is possible that there may
                be events that may not be contained in the
                agent's internal event buffer.
                For example, an agent may read events 50-75.
                At the next read interval, connUnitEventCurrID
                is 189.  If the management app tries to read
                event index 76, and the agent's internal buffer
                is 100 entries max, event index 76 will no longer
                be available.
                The index value is an incrementing integer starting
                from one every time there is a table reset.
                On table reset, all contents are emptied and
                all indeces are set to zero. When an
                event is added to the table, the event is
                assigned the next higher integer value than
                the last item entered into the table. If the
                index value reaches its maximum value, the next
                item entered will cause the index value to
                roll over and start at one again."
            ::= { connUnitEventEntry 2 }

        connUnitEventId OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS deprecated
            DESCRIPTION
                "The internal event Id. Incremented for each
                event, ranging between 1 and connUnitMaxEvents.
                Not used as table index to simplify
                the agent implementation. When this
                reaches the end of the range specified by
                connUnitMaxEvents, the Id will roll over to start
                at one. This value will be set back to one at
                reset. The relationship of this value to the index
                is that internal event id may represent a smaller
                number than a 32 bit integer (eg max 100 entries)
                and would only have a value range up to
                connUnitMaxEvents."
            ::= { connUnitEventEntry 3 }

        connUnitREventTime OBJECT-TYPE
            SYNTAX DisplayString (SIZE (0..15))
            ACCESS read-only
            STATUS mandatory

Blumenau                                                    [Page 29]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

            DESCRIPTION
                "This is the real time when the event occurred.
                It has the following format.
                    DDMMYYYY HHMMSS
                    DD=day number
                    MM=month number
                    YYYY=year number
                    HH=hour number
                    MM=minute number
                    SS=seconds number
                If not applicable, return either a NULL string
                or '00000000 000000'."
            ::= { connUnitEventEntry 4 }

        connUnitSEventTime OBJECT-TYPE
            SYNTAX TimeTicks
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is the sysuptime timestamp when the
                event occurred."
            ::= { connUnitEventEntry 5 }

        connUnitEventSeverity OBJECT-TYPE
            SYNTAX FcEventSeverity
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The event severity level."
            ::= { connUnitEventEntry 6 }

        connUnitEventType OBJECT-TYPE
            SYNTAX INTEGER {
                unknown(1),
                other(2),
                status(3),
                configuration(4),
                topology(5)
            }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The type of this event."
            ::= { connUnitEventEntry 7 }

        connUnitEventObject OBJECT-TYPE
            SYNTAX OBJECT IDENTIFIER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is used with the connUnitEventType
                to identify which object the event refers to.
                Examples are connUnitPortStatus.connUnitId.connUnitPortIndex,
                connUnitStatus.connUnitId, etc."
            ::= { connUnitEventEntry 8 }

Blumenau                                                    [Page 30]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

        connUnitEventDescr OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The description of the event."
            ::= { connUnitEventEntry 9 }

------------------------------------------------------------------
-- The link table
-- is intended to organize and communicate
-- any information the agent possesses
-- which would assist a management application
-- to discover the CONNECTIVITY UNITS in the
-- framework and the TOPOLOGY of their interconnect.
-- That is, the goal is to assist the management
-- application not only to LIST the elements of the framework,
-- but to MAP them.

-- With this goal, the agent SHOULD include
-- as much as it possesses about any links
-- from its own connectivity units to others,
-- including links among its own units.

-- An agent SHOULD include partial information
-- about links if it is not able to fully
-- define them.
-- For an entry to be considered to be valid, both the X (local)
-- and the Y (remote) need to have one valid value.

-- If the agent is able to discover links
-- which do not directly attach to members of its agency
-- and its discovery algorithm gives some assurance
-- the links are recently valid, it MAY include these links.

-- Link information entered by administrative action
-- MAY be included even if not validated directly
-- if the link has at least one endpoint in this agency,
-- but SHOULD NOT be included otherwise.

-- A connectivity unit should fill the table in as best it can.
-- One of the methods to fill this in would be to use the RNID
-- ELS (reference ANSI T11.3 draft standard FC-FS). This
-- allows one to query a port for the information needed for
-- the link table.

-- This table is accessed either directly if the management
-- software has an index value or via GetNexts. The value of
-- the indexes are not required to be contiguous. Each entry
-- created in this table will be assigned an index. This
-- relationship is kept persistent until the entry is removed
-- from the table or the system is reset. The total number of
-- entries are defined by the size of the table

    connUnitLinkTable OBJECT-TYPE

Blumenau                                                    [Page 31]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

        SYNTAX SEQUENCE OF ConnUnitLinkEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of links know to this agent from this
            connectivity unit to other connectivity units."
        ::= { connSet 12 }

    connUnitLinkEntry OBJECT-TYPE
        SYNTAX ConnUnitLinkEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "An entry describing a particular link to another."
        INDEX { connUnitLinkUnitId,
            connUnitLinkIndex }
            ::= { connUnitLinkTable 1 }

        ConnUnitLinkEntry ::=
            SEQUENCE {
                connUnitLinkUnitId
                    FcGlobalId,
                connUnitLinkIndex
                    INTEGER,
                connUnitLinkNodeIdX
                    OCTET STRING,
                connUnitLinkPortNumberX
                    INTEGER,
                connUnitLinkPortWwnX
                    FcGlobalId,
                connUnitLinkNodeIdY
                    OCTET STRING,
                connUnitLinkPortNumberY
                    INTEGER,
                connUnitLinkPortWwnY
                    FcGlobalId,
                connUnitLinkAgentAddressY
                    OCTET STRING,
                connUnitLinkAgentAddressTypeY
                    INTEGER,
                connUnitLinkAgentPortY
                    INTEGER,
                connUnitLinkUnitTypeY
                    FcUnitType,
                connUnitLinkConnIdY
                    OCTET STRING,
                connUnitLinkCurrIndex
                    INTEGER
            }

        connUnitLinkUnitId OBJECT-TYPE
            SYNTAX FcGlobalId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION

Blumenau                                                    [Page 32]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                "The connUnitId of the connectivity unit
                that contains this link table."
            ::= { connUnitLinkEntry 1 }

        connUnitLinkIndex OBJECT-TYPE
            SYNTAX INTEGER (1..2147483647)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This index is used to create a unique value
                for each entry in the link table with the same
                connUnitLinkUnitId. The value
                can only be reused if it is not currently in
                use and the value is the next candidate to
                be used. This value wraps at the highest
                value represented by the size of INTEGER.
                This value is reset to zero when the system is
                reset and the first value to be used is one."
            ::= { connUnitLinkEntry 2 }

        connUnitLinkNodeIdX OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE(16))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The node WWN of the unit at one end
                of the link.  If the node WWN is unknown
                and the node is a connUnit in the responding
                agent then the value of this object MUST BE
                equal to its connUnitID."
            ::= { connUnitLinkEntry 3 }

        connUnitLinkPortNumberX OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The port number on the unit specified by
                connUnitLinkNodeIdX if known, otherwise -1.
                If the value is nonnegative then it will be
                equal to connUnitPortPhysicalNumber."
            ::= { connUnitLinkEntry 4 }

        connUnitLinkPortWwnX OBJECT-TYPE
            SYNTAX FcGlobalId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The port WWN of the unit specified by
                connUnitLinkNodeIdX if known,
                otherwise 16 octets of binary 0"
            ::= { connUnitLinkEntry 5 }

        connUnitLinkNodeIdY OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE(16))

Blumenau                                                    [Page 33]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The node WWN of the unit at the other end
                of the link.  If the node WWN is unknown
                and the node is a connUnit in the responding
                SNMP agency then the value of this object
                MUST BE equal to its connUnitID."
            ::= { connUnitLinkEntry 6 }

        connUnitLinkPortNumberY OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The port number on the unit specified by
                connUnitLinkNodeIdY if known, otherwise -1.
                If the value is nonnegative then it will be
                equal to connUnitPortPhysicalNumber."
            ::= { connUnitLinkEntry 7 }

        connUnitLinkPortWwnY OBJECT-TYPE
            SYNTAX FcGlobalId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The port WWN on the unit specified by
                connUnitLinkNodeIdY if known,
                otherwise 16 octets of binary 0"
            ::= { connUnitLinkEntry 8 }

        connUnitLinkAgentAddressY OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE(16))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The address of an FCMGMT MIB agent for the
                node identified by connUnitLinkNodeIdY,
                if known; otherwise 16 octets of binary 0"
            ::= { connUnitLinkEntry 9 }

        connUnitLinkAgentAddressTypeY OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "If connUnitLinkAgentAddressY is nonzero,
                it is a protocol address.
                ConnUnitLinkAgentAddressTypeY is the
                the 'address family number' assigned by IANA
                to identify the address format.
                (eg, 1 is Ipv4, 2 is Ipv6). If
                connUnitLinkAgentAddressY is all zeros, then
                this value is ignored."
            ::= { connUnitLinkEntry 10 }

Blumenau                                                    [Page 34]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

        connUnitLinkAgentPortY OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The IP port number for the agent. This is
                provided in case the agent is at a non-standard
                SNMP port."
            ::= { connUnitLinkEntry 11 }

        connUnitLinkUnitTypeY OBJECT-TYPE
            SYNTAX FcUnitType
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Type of the FC connectivity unit as defined in
                connUnitType."
            ::= { connUnitLinkEntry 12 }

        connUnitLinkConnIdY OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE(3))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is the Fibre Channel ID of this port.
                If the connectivity unit is a switch, this
                is expected to be a Big Endian value of 24
                bits. If this is loop, then it is the ALPA
                that is connected. If this is an eport, then
                it will only contain the domain ID. If not
                any of those, unknown or cascaded loop,
                return all bits set to 1."
            ::= { connUnitLinkEntry 13 }

        connUnitLinkCurrIndex OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The last used link index."
            ::= { connUnitLinkEntry 14 }

-- The Active Zone table is defined by
-- read-only view of the active zone configuration.
-- Based on the fabric zone server defined in the FC-GS-3 standard and
--      the enhanced zone server proposed for FC-GS-4.
-- Allows alias zone members (GS-4 feature) and includes an alias
--      table.
-- Zone table and Alias table are flat, double-indexed MIB tables.
-- Database view of inactive zone sets is not provided. (Note: This
--      could be added by adding a third index (connUnitZoneSetIndex)
--      and an zone set active flag to the connUnitActiveZonesTable
--      table.)
-- Undefined, vendor-specific bytes have not been included for the bit
--      mask objects connUnitZoneCapabilities and
--      connUnitZoneEnforcementState.
Blumenau                                                    [Page 35]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

    connUnitZoneTable OBJECT-TYPE
        SYNTAX SEQUENCE OF ConnUnitZoneEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            ""
        ::= { connSet 13 }

    connUnitZoneEntry OBJECT-TYPE
        SYNTAX ConnUnitZoneEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            ""
        INDEX { connUnitZoneIndex,
                  connUnitZoneMemberIndex }
            ::= { connUnitZoneTable 1 }

        ConnUnitZoneEntry ::=
            SEQUENCE {
                connUnitZoneIndex
                    INTEGER,
                connUnitZoneMemberIndex
                    INTEGER,
                connUnitZoneSetName
                    DisplayString,
                connUnitZoneSetNumZones
                    INTEGER,
                connUnitZoneName
                    DisplayString,
                connUnitZoneCapabilities
                    OCTET STRING,
                connUnitZoneEnforcementState
                    OCTET STRING,
                connUnitZoneAttributeBlock
                    OCTET STRING,
                connUnitZoneNumMembers
                    INTEGER,
                connUnitZoneMemberIdType
                    INTEGER,
                connUnitZoneMemberID
                    FcGlobalId }

        connUnitZoneIndex OBJECT-TYPE
            SYNTAX INTEGER (1..2147483647)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Unique table index for each zone.
                Valid values are between 1 and
                connUnitZoneSetNumZones."
            ::= { connUnitZoneEntry 1 }

        connUnitZoneMemberIndex OBJECT-TYPE
            SYNTAX INTEGER (1..2147483647)

Blumenau                                                    [Page 36]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Unique table index for each zone
                member. Valid values are between
                1 and connUnitZoneNumMembers."
            ::= { connUnitZoneEntry 2 }

        connUnitZoneSetName OBJECT-TYPE
            SYNTAX DisplayString  (SIZE (0..79))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Name of the active zone set to
                which the zone and zone member
                belong."
            ::= { connUnitZoneEntry 3 }

        connUnitZoneSetNumZones OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The number of zones in the active
                zone set."
            ::= { connUnitZoneEntry 4 }

        connUnitZoneName OBJECT-TYPE
            SYNTAX DisplayString  (SIZE (0..79))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Name of the zone."
            ::= { connUnitZoneEntry 5 }

        connUnitZoneCapabilities OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE(1))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "1-byte bit mask that specifies the
                zoning capabilities supported by the
                fabric.
                Bit 7 - Soft zones supported.
                Bit 6 - Hard zones supported.
                Bits 5-0 - Reserved."
            ::= { connUnitZoneEntry 6 }

        connUnitZoneEnforcementState OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE(1))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "1-byte bit mask that specifies the
                current enforcement of the Zone Set.

Blumenau                                                    [Page 37]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                Bit 7 - Soft zone set enforced.
                Bit 6 - Hard zone set enforced.
                Bits 5-0 - Reserved."
            ::= { connUnitZoneEntry 7 }

        connUnitZoneAttributeBlock OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE(80))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "A variable length structure that
                contains extended zone attributes
                defined in the FC-GS-4 enhanced
                zone server. See FC-GS-4 draft
                standard for details and format of
                the structure.
                Support of this object is optional."
            ::= { connUnitZoneEntry 8 }

        connUnitZoneNumMembers OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of zone members in the
                zone: connUnitZoneName."
            ::= { connUnitZoneEntry 9 }

        connUnitZoneMemberIdType OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Type of zone member ID:
                1- Port WWN
                2- Domain & Port ID
                3- FC Address
                4- Node WWN
                5- Alias Name
                6-'FF'h - Vendor specified."
            ::= { connUnitZoneEntry 10 }

        connUnitZoneMemberID OBJECT-TYPE
            SYNTAX FcGlobalId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "ID of the zone member based on
                connUnitZoneMemberIdType."
            ::= { connUnitZoneEntry 11 }


-- Zone Alias Table

    connUnitZoningAliasTable OBJECT-TYPE

Blumenau                                                    [Page 38]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

        SYNTAX SEQUENCE OF ConnUnitZoningAliasEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            ""
        ::= { connSet 14 }

    connUnitZoningAliasEntry OBJECT-TYPE
        SYNTAX ConnUnitZoningAliasEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            ""
        INDEX { connUnitZoningAliasIndex,
                  connUnitZoningAliasMemberIndex }
            ::= { connUnitZoningAliasTable 1 }

        ConnUnitZoningAliasEntry ::=
            SEQUENCE {
                connUnitZoningAliasIndex
                    INTEGER,
                connUnitZoningAliasMemberIndex
                    INTEGER,
                connUnitZoningAliasNumAliases
                    INTEGER,
                connUnitZoningAliasName
                    DisplayString,
                connUnitZoningAliasNumMembers
                    INTEGER,
                connUnitZoningAliasMemberIdType
                    INTEGER,
                connUnitZoningAliasMemberID
                    FcGlobalId }

        connUnitZoningAliasIndex OBJECT-TYPE
            SYNTAX INTEGER (1..2147483647)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Unique table index for each alias.
                Valid values are between 1 and
                connUnitZoningAliasNumAliases."
            ::= { connUnitZoningAliasEntry 1 }

        connUnitZoningAliasMemberIndex OBJECT-TYPE
            SYNTAX INTEGER (1..2147483647)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Unique table index for each alias
                member. Valid values are between 1
                and connUnitZoningAliasNumMembers."
            ::= { connUnitZoningAliasEntry 2 }

        connUnitZoningAliasNumAliases OBJECT-TYPE

Blumenau                                                    [Page 39]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The number of aliases defined in this
                table."
            ::= { connUnitZoningAliasEntry 3 }

        connUnitZoningAliasName OBJECT-TYPE
            SYNTAX DisplayString  (SIZE (0..79))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The alias name."
            ::= { connUnitZoningAliasEntry 4 }

        connUnitZoningAliasNumMembers OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of members in the alias:
                connUnitZoningAliasName."
            ::= { connUnitZoningAliasEntry 5 }

        connUnitZoningAliasMemberIdType OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Type of alias member ID:
                1- Port WWN
                2- Domain & Port ID
                3- FC Address
                Others: reserved."
            ::= { connUnitZoningAliasEntry 6 }

        connUnitZoningAliasMemberID OBJECT-TYPE
            SYNTAX FcGlobalId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "ID of the alias member based on
                connUnitZoningAliasMemberIdType."
            ::= { connUnitZoningAliasEntry 7 }


------------------------------------------------------------------
-- The following four tables have been obsoleted. These were used to
-- keep statistic information based on the type of port type. It was
-- changed for all ports to use a common statistics table.

--    connUnitPortStatHubTable OBJECT-TYPE
--        SYNTAX SEQUENCE OF ConnUnitPortStatHubEntry
--        ACCESS not-accessible

Blumenau                                                    [Page 40]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

--        STATUS obsolete
--        DESCRIPTION
--            "A list of statistics for the hub port type."
--        ::= { statSet 1 }

--    connUnitPortStatFabricTable OBJECT-TYPE
--        SYNTAX SEQUENCE OF ConnUnitPortStatFabricEntry
--        ACCESS not-accessible
--        STATUS obsolete
--        DESCRIPTION
--            "A list of statistics for the fabric port types."
--        ::= { statSet 2 }

--    connUnitPortStatSCSITable OBJECT-TYPE
--        SYNTAX SEQUENCE OF ConnUnitPortStatSCSIEntry
--        ACCESS not-accessible
--        STATUS obsolete
--        DESCRIPTION
--            "A list of statistics for the SCSI port type."
--        ::= { statSet 3 }

--    connUnitPortStatLANTable OBJECT-TYPE
--        SYNTAX SEQUENCE OF ConnUnitPortStatLANEntry
--        ACCESS not-accessible
--        STATUS obsolete
--        DESCRIPTION
--            "A list of statistics for the LAN/WAN port type."
--        ::= { statSet 4 }

-- There is one and only one statistics table for each
-- individual port. For all objects in statistics table, if the object is not
-- supported by the conn unit then the high order bit is set to 1 with all other
-- bits set to zero. The high order bit is reserved to indicate if the object
-- if supported or not. All objects start at a value of zero at hardware
-- initialization and continue incrementing till end of 63 bits and then
-- wrap to zero.

-- Port Statistics

    connUnitPortStatTable OBJECT-TYPE
        SYNTAX SEQUENCE OF ConnUnitPortStatEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A list of statistics for the fabric port types."
        ::= { statSet 5 }

    connUnitPortStatEntry OBJECT-TYPE
        SYNTAX ConnUnitPortStatEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "An entry describing port statistics."
        INDEX { connUnitPortStatUnitId,
                connUnitPortStatIndex }
            ::= { connUnitPortStatTable 1 }
Blumenau                                                    [Page 41]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

        ConnUnitPortStatEntry ::=
            SEQUENCE {
                connUnitPortStatUnitId
                    FcGlobalId,
                connUnitPortStatIndex
                    INTEGER,
                connUnitPortStatCountError
                    OCTET STRING,
                connUnitPortStatCountTxObjects
                    OCTET STRING,
                connUnitPortStatCountRxObjects
                    OCTET STRING,
                connUnitPortStatCountTxElements
                    OCTET STRING,
                connUnitPortStatCountRxElements
                    OCTET STRING,
                connUnitPortStatCountBBCreditZero
                    OCTET STRING,
                connUnitPortStatCountInputBuffersFull
                    OCTET STRING,
                connUnitPortStatCountFBSYFrames
                    OCTET STRING,
                connUnitPortStatCountPBSYFrames
                    OCTET STRING,
                connUnitPortStatCountFRJTFrames
                    OCTET STRING,
                connUnitPortStatCountPRJTFrames
                    OCTET STRING,
                connUnitPortStatCountClass1RxFrames
                    OCTET STRING,
                connUnitPortStatCountClass1TxFrames
                    OCTET STRING,
                connUnitPortStatCountClass1FBSYFrames
                    OCTET STRING,
                connUnitPortStatCountClass1PBSYFrames
                    OCTET STRING,
                connUnitPortStatCountClass1FRJTFrames
                    OCTET STRING,
                connUnitPortStatCountClass1PRJTFrames
                    OCTET STRING,
                connUnitPortStatCountClass2RxFrames
                    OCTET STRING,
                connUnitPortStatCountClass2TxFrames
                    OCTET STRING,
                connUnitPortStatCountClass2FBSYFrames
                    OCTET STRING,
                connUnitPortStatCountClass2PBSYFrames
                    OCTET STRING,
                connUnitPortStatCountClass2FRJTFrames
                    OCTET STRING,
                connUnitPortStatCountClass2PRJTFrames
                    OCTET STRING,
                connUnitPortStatCountClass3RxFrames
                    OCTET STRING,
                connUnitPortStatCountClass3TxFrames

Blumenau                                                    [Page 42]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                    OCTET STRING,
                connUnitPortStatCountClass3Discards
                    OCTET STRING,
                connUnitPortStatCountRxMulticastObjects
                    OCTET STRING,
                connUnitPortStatCountTxMulticastObjects
                    OCTET STRING,
                connUnitPortStatCountRxBroadcastObjects
                    OCTET STRING,
                connUnitPortStatCountTxBroadcastObjects
                    OCTET STRING,
                connUnitPortStatCountRxLinkResets
                    OCTET STRING,
                connUnitPortStatCountTxLinkResets
                    OCTET STRING,
                connUnitPortStatCountNumberLinkResets
                    OCTET STRING,
                connUnitPortStatCountRxOfflineSequences
                    OCTET STRING,
                connUnitPortStatCountTxOfflineSequences
                    OCTET STRING,
                connUnitPortStatCountNumberOfflineSequences
                    OCTET STRING,
                connUnitPortStatCountLinkFailures
                    OCTET STRING,
                connUnitPortStatCountInvalidCRC
                    OCTET STRING,
                connUnitPortStatCountInvalidTxWords
                    OCTET STRING,
                connUnitPortStatCountPrimitiveSequenceProtocolErrors
                    OCTET STRING,
                connUnitPortStatCountLossofSignal
                    OCTET STRING,
                connUnitPortStatCountLossofSynchronization
                    OCTET STRING,
                connUnitPortStatCountInvalidOrderedSets
                    OCTET STRING,
                connUnitPortStatCountFramesTooLong
                    OCTET STRING,
                connUnitPortStatCountFramesTruncated
                    OCTET STRING,
                connUnitPortStatCountAddressErrors
                    OCTET STRING,
                connUnitPortStatCountDelimiterErrors
                    OCTET STRING,
                connUnitPortStatCountEncodingDisparityErrors
                    OCTET STRING
            }

        connUnitPortStatUnitId OBJECT-TYPE
            SYNTAX FcGlobalId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The connUnitId of the connectivity unit

Blumenau                                                    [Page 43]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                that contains this port stat table."
            ::= { connUnitPortStatEntry 1 }

        connUnitPortStatIndex OBJECT-TYPE
            SYNTAX INTEGER (0..2147483647)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "A unique value among all entries in this
                table having the same connUnitPortStatUnitId,
                between 1 and
                connUnitNumPort[connUnitPortStatUnitId]."
            ::= { connUnitPortStatEntry 2 }

        connUnitPortStatCountError OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "A count of the errors that have occured
                on this port."
            ::= { connUnitPortStatEntry 3 }

        connUnitPortStatCountTxObjects OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The number of frames/packets/IOs/etc that have been transmitted
                by this port. Note: A Fibre Channel frame starts with SOF and
                ends with EOF. FC loop devices should not count frames passed
                through. This value represents the sum total for all other Tx
                objects."
            ::= { connUnitPortStatEntry 4 }

        connUnitPortStatCountRxObjects OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The number of frames/packets/IOs/etc that have been received
                by this port. Note: A Fibre Channel frame starts with SOF and
                ends with EOF. FC loop devices should not count frames passed
                through. This value represents the sum total for all other Rx
                objects."
            ::= { connUnitPortStatEntry 5 }

        connUnitPortStatCountTxElements OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                    "The number of octets or bytes that have been transmitted
                     by this port. One second periodic polling of the port. This
                     value is saved and compared with the next polled value to

Blumenau                                                    [Page 44]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                     compute net throughput. Note, for Fibre Channel, ordered
                     sets are not included in the count."
            ::= { connUnitPortStatEntry 6 }

        connUnitPortStatCountRxElements OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                    "The number of octets or bytes that have been received.
                     by this port. One second periodic polling of the port. This
                     value is saved and compared with the next polled value to
                     compute net throughput. Note, for Fibre Channel, ordered
                     sets are not included in the count."
            ::= { connUnitPortStatEntry 7 }

        connUnitPortStatCountBBCreditZero OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of transitions in/out of BBcredit zero state.
                    The other side is not providing any credit. Note,
                    this is a Fibre Channel stat only."
            ::= { connUnitPortStatEntry 8 }

        connUnitPortStatCountInputBuffersFull OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of occurrences when all input buffers of a
                    port were full and outbound buffer-to-buffer credit
                    transitioned to zero. There is no credit to
                    provide to other side. Note, this is a Fibre Channel
                    stat only."
            ::= { connUnitPortStatEntry 9 }

        connUnitPortStatCountFBSYFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of times that FBSY was returned to this port as a
                    result of a frame that could not be delivered to the other
                    end of the link. This occurs if either the Fabric or the
                    destination port is temporarily busy.  Port can only occur
                    on SOFc1 frames (the frames that establish a connection).
                    Note, this is a Fibre Channel only stat. This is the sum
                    of all classes. If you cannot keep the by class counters,
                    then keep the sum counters."
            ::= { connUnitPortStatEntry 10 }

        connUnitPortStatCountPBSYFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))

Blumenau                                                    [Page 45]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of times that PBSY was returned to this port as a
                    result of a frame that could not be delivered to the other
                    end of the link. This occurs if the destination port is
                    temporarily busy.  PBSY can only occur on SOFc1 frames
                    (the frames that establish a connection). Note, this is
                    a Fibre Channel only stat.This is the sum
                    of all classes. If you cannot keep the by class counters,
                    then keep the sum counters."
            ::= { connUnitPortStatEntry 11 }

        connUnitPortStatCountFRJTFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of times that FRJT was returned to this port as a
                    result of a Frame that was rejected by the fabric. Note,
                    This is the total for all classes and is a Fibre Channel
                    only stat."
            ::= { connUnitPortStatEntry 12 }

        connUnitPortStatCountPRJTFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of times that FRJT was returned to this port as a
                    result of a Frame that was rejected at the destination
                    N_Port. Note, This is the total for all classes and is
                    a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 13 }

        connUnitPortStatCountClass1RxFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of Class 1 Frames received at this port. Note, this
                    is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 14 }

        connUnitPortStatCountClass1TxFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of Class 1 Frames transmitted out this port. Note,
                    this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 15 }

        connUnitPortStatCountClass1FBSYFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))

Blumenau                                                    [Page 46]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of times that FBSY was returned to this port as a
                    result of a Class 1 Frame that could not be delivered to the
                    other end of the link. This occurs if either the Fabric or the
                    destination port is temporarily busy.  FBSY can only occur on
                    SOFc1 frames (the frames that establish a connection). Note,
                    this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 16 }

        connUnitPortStatCountClass1PBSYFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of times that PBSY was returned to this port as a result
                    of a Class 1 Frame that could not be delivered to the other end
                    of the link. This occurs if the destination N_Port is temporarily
                    busy.  PBSY can only occur on SOFc1 frames (the frames that
                    establish a connection). Note, this is a Fibre Channel only
                    stat."
            ::= { connUnitPortStatEntry 17 }

        connUnitPortStatCountClass1FRJTFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of times that FRJT was returned to this port as a result
                    of a Class 1 Frame that was rejected by the fabric. Note, this
                    is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 18 }

        connUnitPortStatCountClass1PRJTFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of times that FRJT was returned to this port as a result
                    of a Class 1 Frame that was rejected at the destination N_Port.
                    Note, this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 19 }

        connUnitPortStatCountClass2RxFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of Class 2 Frames received at this port. Note, this
                    is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 20 }

        connUnitPortStatCountClass2TxFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))

Blumenau                                                    [Page 47]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of Class 2 Frames transmitted out this port. Note,
                    this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 21 }

        connUnitPortStatCountClass2FBSYFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of times that FBSY was returned to this port as a
                    result of a Class 2 Frame that could not be delivered to the
                    other end of the link. This occurs if either the Fabric or the
                    destination port is temporarily busy.  FBSY can only occur on
                    SOFc1 frames (the frames that establish a connection). Note,
                    this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 22 }

        connUnitPortStatCountClass2PBSYFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of times that PBSY was returned to this port as a result
                    of a Class 2 Frame that could not be delivered to the other end
                    of the link. This occurs if the destination N_Port is temporarily
                    busy.  PBSY can only occur on SOFc1 frames (the frames that
                    establish a connection). Note, this is a Fibre Channel only
                    stat."
            ::= { connUnitPortStatEntry 23 }

        connUnitPortStatCountClass2FRJTFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of times that FRJT was returned to this port as a result
                    of a Class 2 Frame that was rejected by the fabric. Note, this
                    is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 24 }

        connUnitPortStatCountClass2PRJTFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of times that FRJT was returned to this port as a result
                    of a Class 2 Frame that was rejected at the destination N_Port.
                    Note, this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 25 }

        connUnitPortStatCountClass3RxFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))

Blumenau                                                    [Page 48]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of Class 3 Frames received at this port. Note, this
                    is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 26 }

        connUnitPortStatCountClass3TxFrames OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of Class 3 Frames transmitted out this port. Note,
                    this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 27 }

        connUnitPortStatCountClass3Discards OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of Class 3 Frames that were discarded upon reception
                    at this port.  There is no FBSY or FRJT generated for Class 3
                    Frames.  They are simply discarded if they cannot be delivered.
                    Note, this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 28 }

        connUnitPortStatCountRxMulticastObjects OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of Multicast Frames or Packets received at this port."
            ::= { connUnitPortStatEntry 29 }

        connUnitPortStatCountTxMulticastObjects OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of Multicast Frames or Packets transmitted out this port."
            ::= { connUnitPortStatEntry 30 }

        connUnitPortStatCountRxBroadcastObjects OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of Broadcast Frames or Packets received at this port."
            ::= { connUnitPortStatEntry 31 }

        connUnitPortStatCountTxBroadcastObjects OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory

Blumenau                                                    [Page 49]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

            DESCRIPTION
                   "Count of Broadcast Frames or Packets transmitted out this port.
                    On a Fibre Channel loop, count only OPNr frames generated."
            ::= { connUnitPortStatEntry 32 }

        connUnitPortStatCountRxLinkResets OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of Link resets. This is the number of LRs received. Note, this
                    is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 33 }

        connUnitPortStatCountTxLinkResets OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of Link resets. This is the number LRs  transmitted. Note, this
                    is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 34 }

        connUnitPortStatCountNumberLinkResets OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of Link resets and LIPs detected at this port.
                    The number times the reset link protocol is initiated.
                    These are the count of the logical resets, a count of the
                    number of primatives. Note, this is a Fibre Channel only
                    stat."
            ::= { connUnitPortStatEntry 35 }

        connUnitPortStatCountRxOfflineSequences OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of Offline Primitive OLS received at this port.
                    Note, this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 36 }

        connUnitPortStatCountTxOfflineSequences OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of Offline Primitive OLS transmitted by this port.
                    Note, this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 37 }

        connUnitPortStatCountNumberOfflineSequences OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))

Blumenau                                                    [Page 50]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of Offline Primitive sequence received at this port.
                    Note, this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 38 }

        connUnitPortStatCountLinkFailures OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of link failures. This count is part of the Link Error
                    Status Block (LESB). (FC-PH 29.8). Note, this is a Fibre
                    Channel only stat."
            ::= { connUnitPortStatEntry 39 }

        connUnitPortStatCountInvalidCRC OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of frames received with invalid CRC. This count is
                    part of the Link Error Status Block (LESB). (FC-PH 29.8). Loop
                    ports should not count CRC errors passing through when
                    monitoring. Note, this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 40 }

        connUnitPortStatCountInvalidTxWords OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of invalid transmission words received at this
                    port. This count is part of the Link Error Status Block (LESB).
                   (FC-PH 29.8). Note, this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 41 }

        connUnitPortStatCountPrimitiveSequenceProtocolErrors OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of primitive sequence protocol errors detected at
                    this port. This count is part of the Link Error Status
                    Block (LESB). (FC-PH 29.8). Note, this is a Fibre Channel
                    only stat."
            ::= { connUnitPortStatEntry 42 }

        connUnitPortStatCountLossofSignal OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of instances of signal loss detected at port.

Blumenau                                                    [Page 51]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                    This count is part of the Link Error Status Block (LESB).
                    (FC-PH 29.8). Note, this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 43 }

        connUnitPortStatCountLossofSynchronization OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of instances of synchronization loss detected at port.
                    This count is part of the Link Error Status Block (LESB).
                    (FC-PH 29.8). Note, this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 44 }

        connUnitPortStatCountInvalidOrderedSets OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of invalid ordered sets received at port. This count
                    is part of the Link Error Status Block (LESB). (FC-PH 29.8).
                    Note, this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 45 }

        connUnitPortStatCountFramesTooLong OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of frames received at this port where the
                    frame length was greater than what was agreed to in
                    FLOGI/PLOGI. This could be caused by losing the end of
                    frame delimiter. Note, this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 46 }

        connUnitPortStatCountFramesTruncated OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of frames received at this port where the
                    frame length was less than the minimum indicated by the
                    frame header - normally 24 bytes, but it could be more if the
                    DFCTL field indicates an optional header should have been
                    present. Note, this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 47 }

        connUnitPortStatCountAddressErrors OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of frames received with unknown addressing.
                    e.x. unknown SID or DID. the SID or DID is not known to the
                    routing algorithm. Note. this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 48 }
Blumenau                                                    [Page 52]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

        connUnitPortStatCountDelimiterErrors OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of invalid frame delimiters received at this
                    port. An example is a frame with a class 2 start and and a
                    class 3 at the end. Note, this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 49 }

        connUnitPortStatCountEncodingDisparityErrors OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE (8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                   "Count of disparity errors received at this port. Note,
                    this is a Fibre Channel only stat."
            ::= { connUnitPortStatEntry 50 }

------------------------------------------------------------------
--
-- the Fibre Channel Simple Name Server table
--
-- The Fibre Channel Simple Name Server table contains an entry for each device
-- presently known to this connUnit. There will not be any version on this since
-- FC-GS3 does not define a version today.
--
-- This table is accessed either directly if the management
-- software has an index value or via GetNexts. The value of
-- the indexes are not required to be contiguous.
-- The total number of entries are defined by the size of the table

    connUnitSnsMaxEntry OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The current number of entries in the table."
        ::= { connUnitServiceScalars 1 }

    connUnitSnsTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF ConnUnitSnsEntry
        ACCESS      not-accessible
        STATUS      mandatory
        DESCRIPTION
            "This table contains an entry for each object registered with
             this port in the switch."
        ::= { connUnitServiceTables 1 }

    connUnitSnsEntry OBJECT-TYPE
        SYNTAX      ConnUnitSnsEntry
        ACCESS      not-accessible
        STATUS      mandatory
        DESCRIPTION
            "The Simple Name Server table for the port represented by

Blumenau                                                    [Page 53]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

             ConnUnitSnsPortIndex ."
        INDEX { connUnitSnsId, connUnitSnsPortName,
                connUnitSnsPortIdentifier }
        ::= { connUnitSnsTable 1 }

        ConnUnitSnsEntry ::=
            SEQUENCE {
               connUnitSnsId
                    OCTET STRING,
               connUnitSnsPortIndex
                    INTEGER,
                connUnitSnsPortIdentifier
                    FcAddressId,
                connUnitSnsPortName
                    FcNameId,
                connUnitSnsNodeName
                    FcNameId,
                connUnitSnsClassOfSvc
                    OCTET STRING,
                connUnitSnsNodeIPAddress
                    OCTET STRING,
                connUnitSnsProcAssoc
                    OCTET STRING,
                connUnitSnsFC4Type
                    OCTET STRING,
                connUnitSnsPortType
                    OCTET STRING,
                connUnitSnsPortIPAddress
                    OCTET STRING,
                connUnitSnsFabricPortName
                    FcNameId,
                connUnitSnsHardAddress
                    FcGlobalId,
                connUnitSnsSymbolicPortName
                    DisplayString,
                connUnitSnsSymbolicNodeName
                    DisplayString
            }

    connUnitSnsId OBJECT-TYPE
        SYNTAX OCTET STRING (SIZE (16))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The connUnitId of the connectivity unit
            that contains this Name Server table."
        ::= { connUnitSnsEntry 1 }

    connUnitSnsPortIndex OBJECT-TYPE
        SYNTAX      INTEGER
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
            "The physical port number of this SNS table entry.
            Each physical port has an SNS table with 1-n entries

Blumenau                                                    [Page 54]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

            indexed by ConnUnitSnsPortIdentifier (port address)"
        ::= { connUnitSnsEntry 2 }

    connUnitSnsPortIdentifier OBJECT-TYPE
        SYNTAX      FcAddressId
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
            "The Fibre Channel ID for this entry in the SNS table."
        ::= { connUnitSnsEntry 3 }

    connUnitSnsPortName OBJECT-TYPE
        SYNTAX      FcNameId
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
            "The Port WWN for this entry in the SNS table."
        ::= { connUnitSnsEntry 4 }

    connUnitSnsNodeName OBJECT-TYPE
        SYNTAX      FcNameId
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
            "The Node Name for this entry in the SNS table."
        ::= { connUnitSnsEntry 5 }

    connUnitSnsClassOfSvc OBJECT-TYPE
        SYNTAX OCTET STRING (SIZE (1))
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
            "The Classes of Service offered by this entry in the SNS table.
            This is a bit mask where each bit that represents the class
            of service is set to a value of one if the class is supported.
            Class 1 is bit zero."
        ::= { connUnitSnsEntry 6 }

    connUnitSnsNodeIPAddress OBJECT-TYPE
        SYNTAX OCTET STRING (SIZE(16))
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
            "The IPv6 formatted address of the Node for this entry in the
            SNS table."
        ::= { connUnitSnsEntry 7 }

    connUnitSnsProcAssoc OBJECT-TYPE
        SYNTAX OCTET STRING (SIZE (8))
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
            "The Process Associator for this entry in the SNS table."
        ::= { connUnitSnsEntry 8 }


Blumenau                                                    [Page 55]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

    connUnitSnsFC4Type OBJECT-TYPE
        SYNTAX OCTET STRING (SIZE (32))
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
            "The FC-4 Types supported by this entry in the SNS table."
        ::= { connUnitSnsEntry 9 }

    connUnitSnsPortType OBJECT-TYPE
        SYNTAX OCTET STRING (SIZE (1))
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
            "The Port Type of this entry in the SNS table."
        ::= { connUnitSnsEntry 10 }

    connUnitSnsPortIPAddress OBJECT-TYPE
        SYNTAX OCTET STRING (SIZE(16))
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
            "The IPv6 formatted address of this entry in the SNS table."
        ::= { connUnitSnsEntry 11 }

    connUnitSnsFabricPortName OBJECT-TYPE
        SYNTAX      FcNameId
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
            "The Fabric Port name of this entry in the SNS table."
        ::= { connUnitSnsEntry 12 }

    connUnitSnsHardAddress OBJECT-TYPE
        SYNTAX      FcGlobalId
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
            "The Hard ALPA of this entry in the SNS table."
        ::= { connUnitSnsEntry 13 }

    connUnitSnsSymbolicPortName OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..79))
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
            "The Symbolic Port Name of this entry in the SNS table."
        ::= { connUnitSnsEntry 14 }

    connUnitSnsSymbolicNodeName OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..79))
        ACCESS      read-only
        STATUS      mandatory
        DESCRIPTION
            "The Symbolic Node Name of this entry in the SNS table."
        ::= { connUnitSnsEntry 15 }

Blumenau                                                    [Page 56]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

-- Platform Table
-- Design Objectives and Scope
--  Simple, read-only view of platform registration entries.
--  Platform registry is a service hosted by the connectivity unit,
--  in a very similar manner as the SNS table. I.E., the platform
--  table is contained by the connectivity unit. A platform can
--  register it's attributes and platform nodes with the registry
--  service. (See FC-GS-3 Configuration Server for details.)
--  The platform table is a flat, double-indexed MIB table.
--  To keep the table simple, only one platform management URL is exposed.
--  If a platform registers more than one management URL, the first
--  one is reported in this table.
--  This table is based on the fabric configuration server
--   defined in the FC-GS-3 standard and enhanced platform
--   attributes proposed for FC-GS-4.
--  Note that the information contained in this table may only
--   contain the platforms that this connUnit can see or it may
--   contain a fabric wide view of the platforms.

    connUnitPlatformMaxEntry OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The maximum number of entries in the platform table."
        ::= { connUnitServiceScalars 2 }

    connUnitPlatformTable OBJECT-TYPE
        SYNTAX SEQUENCE OF ConnUnitPlatformEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            ""
        ::= { connUnitServiceTables 2 }

    connUnitPlatformEntry OBJECT-TYPE
        SYNTAX ConnUnitPlatformEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            ""
        INDEX { connUnitPlatformIndex,
                  connUnitPlatformNodeIndex }
            ::= { connUnitPlatformTable 1 }

        ConnUnitPlatformEntry ::=
            SEQUENCE {
                connUnitPlatformIndex
                    INTEGER,
                connUnitPlatformNodeIndex
                    INTEGER,
                connUnitPlatformUnitID
                    FcGlobalId,
                connUnitPlatformName
                    OCTET STRING,

Blumenau                                                    [Page 57]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

                connUnitPlatformType
                    FcUnitType,
                connUnitPlatformLabel
                    DisplayString,
                connUnitPlatformDescription
                    DisplayString,
                connUnitPlatformLocation
                    DisplayString,
                connUnitPlatformManagementUrl
                    DisplayString,
                connUnitPlatformNumNodes
                    INTEGER,
                connUnitPlatformNodeName
                    FcGlobalId }

        connUnitPlatformIndex OBJECT-TYPE
            SYNTAX INTEGER (1..2147483647)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Unique table index for each platform.
                Valid values are between 1 and
                connUnitPlatformsMaxEntry."
            ::= { connUnitPlatformEntry 1 }

        connUnitPlatformNodeIndex OBJECT-TYPE
            SYNTAX INTEGER (1..2147483647)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Unique table index for each platform
                node. Valid values are between 1 and
                connUnitPlatformsNumNodes."
            ::= { connUnitPlatformEntry 2 }

        connUnitPlatformUnitID OBJECT-TYPE
            SYNTAX FcGlobalId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The connUnitId of the connectivity
                unit that contains this Platform table."
            ::= { connUnitPlatformEntry 3 }

        connUnitPlatformName OBJECT-TYPE
            SYNTAX OCTET STRING (SIZE(79))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The platform name. May be either a
                readable string or a unique ID format
                as specified in the FC-GS-4 draft
                standard."
            ::= { connUnitPlatformEntry 4 }


Blumenau                                                    [Page 58]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

        connUnitPlatformType OBJECT-TYPE
            SYNTAX FcUnitType
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The platform type."
            ::= { connUnitPlatformEntry 6 }


        connUnitPlatformLabel OBJECT-TYPE
            SYNTAX DisplayString (SIZE (0..79))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "An administratively assigned symbolic
                name for the platform. The Platform
                Label shall only contain print-able
                ASCII characters."
            ::= { connUnitPlatformEntry 7 }

        connUnitPlatformDescription OBJECT-TYPE
            SYNTAX DisplayString (SIZE (0..79))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "A textual description of the platform.
                This value should include the full name
                and version identification of
                the platform's hardware type and
                software operating system. The
                Platform Description shall only contain
                printable ASCII characters."
            ::= { connUnitPlatformEntry 8 }

        connUnitPlatformLocation OBJECT-TYPE
            SYNTAX DisplayString (SIZE (0..79))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The physical location of the platform
                (e.g., telephone closet, 3rd floor). The
                Platform Location shall only
                contain printable ASCII characters."
            ::= { connUnitPlatformEntry 9 }

        connUnitPlatformManagementUrl OBJECT-TYPE
            SYNTAX DisplayString (SIZE (0..79))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Primary management URL for the
                platform. If the platform registers
                more than one URL, then this URL is
                equal to the first in the list."
            ::= { connUnitPlatformEntry 10 }

Blumenau                                                    [Page 59]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

        connUnitPlatformNumNodes OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of nodes contained in the
                platform."
            ::= { connUnitPlatformEntry 11 }


        connUnitPlatformNodeName OBJECT-TYPE
            SYNTAX FcGlobalId
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The name (WWN - world wide name)
                of the node contained by the platform."
            ::= { connUnitPlatformEntry 12 }



-- SNMP trap registration group

    trapMaxClients OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The maximum number of SNMP trap recipients
            supported by the connectivity unit."
        ::= { trapReg 1 }

    trapClientCount OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The current number of rows in the trap table."
        ::= { trapReg 2 }

    trapRegTable OBJECT-TYPE
        SYNTAX SEQUENCE OF TrapRegEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "A table containing a row for each IP address/port
            number that traps will be sent to."
        ::= { trapReg 3 }

    trapRegEntry OBJECT-TYPE
        SYNTAX TrapRegEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Ip/Port pair for a specific client."

Blumenau                                                    [Page 60]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

        INDEX { trapRegIpAddress,
                trapRegPort }
        ::= { trapRegTable 1 }

    TrapRegEntry ::=
        SEQUENCE {
            trapRegIpAddress
                IpAddress,
            trapRegPort
                INTEGER (1..2147483647),
            trapRegFilter
                FcEventSeverity,
            trapRegRowState
                INTEGER
        }

    trapRegIpAddress OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The Ip address of a client registered for
            traps."
        ::= { trapRegEntry 1 }

    trapRegPort OBJECT-TYPE
        SYNTAX INTEGER (1..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The UDP port to send traps to for this host.
            Normally this would be the standard trap port
            (162).  This object is an index and must be
            specified to create a row in this table."
        ::= { trapRegEntry 2 }

    trapRegFilter OBJECT-TYPE
        SYNTAX FcEventSeverity
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value defines the trap severity
            filter for this trap host. The connUnit will send
            traps to this host that have a severity level
            less than or equal to this value.
            The default value of this object is 'warning'."
        ::= { trapRegEntry 3}

    trapRegRowState OBJECT-TYPE
        SYNTAX INTEGER {
            rowDestroy(1), -- Remove row from table.
            rowInactive(2), -- Row exists, but TRAPs disabled
            rowActive(3)   -- Row exists and is enabled for
                           -- sending traps
        }

Blumenau                                                    [Page 61]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "Specifies the state of the row.
            rowDestroy
                READ: Can never happen.
                WRITE: Remove this row from the table.
            rowInactive
                READ: Indicates that this row does exist, but
                      that traps are not enabled to be sent to the
                      target.
                WRITE: If the row does not exist, and the agent
                       allows writes to the trap table, then a new
                       row is created. The values of the optional
                       columns will be set to default values. Traps are
                       not enabled to be sent to the target. If the row
                       already existed, then traps are disabled from being
                       sent to the target.
            rowActive
                READ: Indicates that this row exists, and that traps
                      are enabled to be sent to the target.
                WRITE: If the row does not exist, and the agent
                      allows writes to the trap table, then a new row is
                      created. The values of the optional columns will be
                      set to default values. Traps are enabled to be sent
                      to the target. If the row already exists, then traps
                      are enabled to be sent to the target.

            A value of rowActive or rowInactive must be specified to
            create a row in the table."
        ::= { trapRegEntry 4}


-- Related traps

    connUnitStatusChange TRAP-TYPE
        ENTERPRISE fcmgmt
        VARIABLES { connUnitStatus, connUnitState }
        DESCRIPTION
            "The overall status of the connectivity unit has
            changed.
            Recommended severity level (for filtering): alert"
        ::= 1

    -- connUnitAddedTrap , 2, no longer used

    connUnitDeletedTrap TRAP-TYPE
        ENTERPRISE fcmgmt
        VARIABLES { connUnitId }
        DESCRIPTION
            "A connUnit has been deleted from this agent.
            Recommended severity level (for filtering): warning"
        ::= 3

    connUnitEventTrap TRAP-TYPE

Blumenau                                                    [Page 62]


INTERNET-DRAFT           FC Mgmt Integration MIB         Sep 17, 2001

        ENTERPRISE fcmgmt
        VARIABLES { connUnitEventId,
                    connUnitEventType,
                    connUnitEventObject,
                    connUnitEventDescr }
        DESCRIPTION
            "An event has been generated by the
            connectivity unit.
            Recommended severity level (for filtering): info"
        ::= 4

    connUnitSensorStatusChange TRAP-TYPE
        ENTERPRISE fcmgmt
        VARIABLES { connUnitSensorStatus }
        DESCRIPTION
            "The overall status of the connectivity unit has
            changed.
            Recommended severity level (for filtering): alert"
        ::= 5

    connUnitPortStatusChange TRAP-TYPE
        ENTERPRISE fcmgmt
        VARIABLES { connUnitPortStatus, connUnitPortState }
        DESCRIPTION
            "The overall status of the connectivity unit has
            changed.
            Recommended severity level (for filtering): alert"
        ::= 6

END




Author Contact Information:

Steven Blumenau
EMC Corporation
171 South Street
Hopkinton, MA 01748-9103
USA
Phone: 1-508-435-1000 x24657
E-mail: blumenau_steven@emc.com

(This draft expires Mar 17, 2002.)











Blumenau                                                    [Page 63]