                        Power Management Architecture
                    draft-claise-power-management-arch-02
     
     
     Status of this Memo
     
        This Internet-Draft is submitted to IETF in full conformance
        with the provisions of BCP 78 and BCP 79.
     
        Internet-Drafts are working documents of the Internet
        Engineering Task Force (IETF), its areas, and its working
        groups.  Note that other groups may also distribute working
        documents as Internet-Drafts.
     
        Internet-Drafts are draft documents valid for a maximum of six
        months and may be updated, replaced, or obsoleted by other
        documents at any time.  It is inappropriate to use Internet-
        Drafts as reference material or to cite them other than as
        "work in progress."
     
        The list of current Internet-Drafts can be accessed at
        http://www.ietf.org/ietf/1id-abstracts.txt
     
        The list of Internet-Draft Shadow Directories can be accessed
        at http://www.ietf.org/shadow.html
     
        This Internet-Draft will expire on September, 2010.
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     <Claise, et. Al>        Expires April 20 2011            [Page 1]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
     
     Copyright Notice
     
        Copyright (c) 2010 IETF Trust and the persons identified as the
        document authors.  All rights reserved.
     
        This document is subject to BCP 78 and the IETF Trust's Legal
        Provisions Relating to IETF Documents
        (http://trustee.ietf.org/license-info) in effect on the date of
        publication of this document.  Please review these documents
        carefully, as they describe your rights and restrictions with
        respect to this document.  Code Components extracted from this
        document must include Simplified BSD License text as described
        in Section 4.e of the Trust Legal Provisions and are provided
        without warranty as described in the Simplified BSD License.
     
     
     Abstract
     
        This document defines the power management architecture.
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     <Claise, et. Al>        Expires April 20, 2011            [Page 2]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
     
     
     
     Table of Contents
     
        1. Introduction.............................................. 4
        2. Use Cases & Requirements.................................. 5
        3. Terminology............................................... 5
        4. Energy Management Reference Model......................... 7
        5. Architecture High Level Concepts and Scope................ 9
           5.1. Power Monitor Information........................... 11
           5.2. Power Monitor Meter Domain.......................... 11
           5.3. Power Monitor Parent and Child...................... 11
           5.4. Power Monitor Context............................... 12
           5.5. Power Monitor Levels................................ 13
           5.6. Power Monitor Usage Measurement..................... 16
           5.7. Optional Power Usage Quality........................ 17
           5.8. Optional Energy Measurement......................... 18
           5.9. Optional Battery Information........................ 18
        6. Power Monitor Children Discovery......................... 18
        7. Configuration............................................ 19
        8. Fault Management......................................... 20
        9. IPFIX.................................................... 20
        10. Relationship with Other Standards Development
        Organizations............................................... 21
           10.1. Information Modeling............................... 21
           10.2. Power Levels....................................... 21
        11. Implementation Scenarios................................ 22
           Scenario 1: Switch with PoE endpoints.................... 22
           Scenario 2: Switch with PoE endpoints with further connected
           device(s)................................................ 22
           Scenario 3: A switch with Wireless Access Points......... 22
           Scenario 4: Network connected facilities gateway......... 23
           Scenario 5: Data center network.......................... 23
           Scenario 6: Building gateway device...................... 23
           Scenario 7: Power consumption of UPS..................... 23
           Scenario 8: Power consumption of battery-based devices... 24
        12. Security Considerations................................. 24
        12.1. Security Considerations for SNMP...................... 24
        12.2. Security Considerations for IPFIX..................... 25
        13. IANA Considerations..................................... 25
        14. Acknowledgments......................................... 25
        15. References.............................................. 25
           Normative References..................................... 25
           Informative References................................... 26
     
     
     
     
     
     <Claise, et. Al>        Expires April 20, 2011            [Page 3]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
     
     
        TO DO
     
             - Question for the Working Group: Should the WG consider
               IPFIX in this architecture?
     
             - Question for the Working Group: How to specify the notion
               of child capabilities, i.e. the capabilities that the
               Power Monitor Parents have with Power Monitor Children.
               For Example:
                  1. Monitoring (only reporting)
                  2. Configuration power state
                  3. Configuration: power
              Example: on a PC, we can set power level without knowing
              the power. A solution must be specified in this draft.
     
             - Question for the Working Group: Should transition states
               be tracked when setting a level. Example: The configured
               level is set to Off from High.  The Actual level will
               take time to update as the device powers down. Should
               there be transitions shown or will the two variables
               suffice to track the device state.
     
             - Question for working group: Should implementation
               scenarios be incorporated in the architecture draft
     
             - We should have a similar section, for all the drafts,
               which includes an overview of all EMAN documents.
     
     1. Introduction
     
        Network management is typically divided into the five main
        network management areas defined in the ISO Telecommunications
        Management Network model: Fault, Configuration, Accounting,
        Performance, and Security Management.  Absent from this model is
        any consideration of energy management, which is now becoming a
        critical area of concern worldwide.
     
        This document defines an architecture for power management for
        devices within or connected to communication networks.  This
        architecture includes monitoring for power state and energy
        consumption of networked elements, covering the requirements
        specified in [POWER-MON-REQ].  It also goes a step further in
        defining some elements of configuration.
     
     
     
     
     
     <Claise, et. Al>        Expires April 20, 2011            [Page 4]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
        Energy management is applicable to devices in communication
        networks.  Target devices for this specification include (but
        are not limited to): routers, switches, Power over Ethernet
        (PoE) endpoints, protocol gateways for building management
        systems, intelligent meters, home energy gateway, hosts and
        servers, sensor proxies, etc.
     
        Where applicable, device monitoring extends to the individual
        components of the device and to any attached dependent devices.
        For example: A device can contain components that are
        independent from a power-state point of view, such as line
        cards, processor cards, hard drives. A device can also have
        dependent attached devices, such as a switch with PoE endpoints
        or a power distribution unit with attached endpoints.
     
     
     2. Use Cases & Requirements
     
        Requirements for power and energy monitoring for networking
        devices are specified in [POWER-MON-REQ].  The requirements in
        [POWER-MON-REQ] cover devices typically found in communications
        networks, such as switches, routers, and various connected
        endpoints.  For a power monitoring architecture to be useful, it
        should also apply to facility meters, power distribution units,
        gateway proxies for commercial building control, home automation
        devices, and devices that interface with the utility and/or
        smart grid.  Accordingly, this architecture, the scope is
        broader than that specified in [POWER-MON-REQ].  Several
        scenarios that cover these broader use cases are presented later
        in Section 11. - Implementation Scenarios.
     
     
     3. Terminology
     
        This section contains definitions of important terms used
        throughout this specification.
     
        IPFIX-specific terminology used in this document is defined in
        section 2 of [RFC5101]. For example: Flow Record, Collector ,
        etc...  As in [RFC5101], these IPFIX-specific terms have the
        first letter of a word capitalized.
     
     
        Power Monitor
     
        A Power Monitor is a component within a system of components
        that provides power, draws power, or reports energy consumption
        on behalf of another Power Monitor.  It can be independently
     
     
     <Claise, et. Al>        Expires April 20, 2011            [Page 5]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
        managed from a power-monitoring and power-state configuration
        point of view.  Examples of Power Monitors are: a router line
        card, a motherboard with a CPU, an IP phone connected with a
        switch, etc.
     
     
        Power Monitor Parent
     
        A Power Monitor Parent is a Power Monitor that is the root of
        one or more subtending Power Monitors, called Power Monitor
        Children.  The Power Monitor Parent is able to collect data
        about or report on the power state and energy consumption of its
        Power Monitor Children.
     
        For example: A Power-over-Ethernet (PoE) device (such as an IP
        phone or an access point) is attached to a switch port. The
        switch is the source of power for the attached device, so the
        Power Monitor Parent is the switch, and the Power Monitor Child
        is the device attached to the switch.
     
        The Power Monitor Parent may report data or implement actions on
        behalf of the Power Monitor Child.  These capabilities must be
        enumerated by the Power Monitor Parent.
     
        The communication between the parent and child for monitoring or
        collection of power data is left to the device manufacturer. For
        example: A parent switch may use LLDP to communicate with a
        connected child, and a parent lighting controller may use BACNET
        to communicate with child lighting devices.
     
     
        Power Monitor Child
     
        A Power Monitor Child is a Power Monitor associated with a Power
        Monitor Parent, and which reports its power usage and power
        state to its Power Monitor Parent. The Power Monitor Child may
        or may not draw power from its Power Monitor Parent. .
     
     
        Power Monitor Meter Domain
     
        A Power Monitor Meter Domain is a name or name space that
        logically groups Power Monitors into a zone of manageable power
        usage.  Typically, this zone will have as members all Power
        Monitors that are powered from the same electrical panel or
        panels for which there is a meter or sub meter.  For example:
        All Power Monitors receiving power from the same distribution
        panel of a building, or all Power Monitors in a building for
     
     
     <Claise, et. Al>        Expires April 20, 2011            [Page 6]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
        which there is one main meter, would comprise a Power Monitor
        Meter Doman.  From the standpoint of power-use monitoring, it is
        useful to report the total power usage as the sum of power
        consumed by all the Power Monitors within a Power Monitor Meter
        Domain and then correlate that value with the metered usage.
     
     
        Power Level
     
        A Power Level is a uniform way to classify power settings on a
        Power Monitor (e.g., shut, hibernate, sleep, high).  Power
        Levels can be viewed as an interface for the underlying device-
        implemented power settings.
     
     
        Manufacturer Power Level
     
        A Manufacturer Power Level is a device-specific way to classify
        power settings implemented on a Power Monitor.  For cases where
        the implemented power settings cannot be directly mapped to
        Power Levels, we can use the Manufacturer Power Levels to
        enumerate and show the relationship between the implemented
        power settings and the Power Level interface.
     
     
     4. Energy Management Reference Model
     
     
                       +---------------+
                       |      NMS      |              -
                       +-----+---+-----+              |
                             |  |                     |
                             |  |                     |  S
                   +---------+  +-------+             |  N
                   |                     |            |  M
                   |                     |            |  P
           +---------------+      +------+-------+    |
           | Power Monitor |      | Power Monitor |   |
           | Parent 1      | ...  | Parent N      |   -
           +---------------+      +---------------+
                   |||
         (protocol |||
         out of    |||      +-------------+---------+
         the scope)|||------| Power Monitor Child 1 |
                   ||       +-----------------------+
                   ||
                   ||       +-------------+---------+
                   ||-------| Power Monitor Child 2 |
     
     
     <Claise, et. Al>        Expires April 20, 2011            [Page 7]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
                   |        +-----------------------+
                   |
                   |
                   |--------           ...
                   |
                   |
                   |        +-------------+---------+
                   |--------| Power Monitor Child M |
                            +-----------------------+
     
     
     
                Figure 1: Energy Management Pull Reference Model
     
        In this architecture a Network Management Station (NMS) will
        poll MIB variables on a Power Monitors via SNMP.  The Power
        Monitor returns information for itself and for any Power Monitor
        Children if applicable.  The information returned will contain
        business context, energy usage, power quality and other
        information as described further.
     
        The protocol between the Power Monitor Parent and Power Monitor
        Children is out of scope of this document.  The Power Monitor
        Parent may speak to a Power Monitor Child using a manufacturer
        selected protocol.  This protocol may or may not based on IP.
        In this way, a Power Monitor Parent acts as a PROXY for protocol
        translation between the Power Monitor Parent and Child.  The
        Power Monitor Parent also acts as an aggregation point for other
        subtended Power Monitor Children.
     
                       +---------------+
                       | NMS/Collector |              ^  S
                       +-----+---+-----+              |  N
                             |  |                     |  M     I
                             |  |                     |  P     P
                   +---------+  +-------+             |     &  F
                   |                     |            |  N     I
                   |                     |            |  O     X
           +---------------+      +------+-------+    |  T
           | Power Monitor |      | Power Monitor |   |  .
           | Parent 1      | ...  | Parent N      |   -
           +---------------+      +---------------+
                   |||
         (protocol |||
         out of    |||      +-------------+---------+
         the scope)|||------| Power Monitor Child 1 |
                   ||       +-----------------------+
                   ||
     
     
     <Claise, et. Al>        Expires April 20, 2011            [Page 8]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
                   ||       +-------------+---------+
                   ||-------| Power Monitor Child 2 |
                   |        +-----------------------+
                   |
                   |
                   |--------           ...
                   |
                   |
                   |        +-------------+---------+
                   |--------| Power Monitor Child M |
                            +-----------------------+
     
     
                Figure 2: Energy Management PUSH Reference Model
     
        The Power Monitor Parents may send SNMP notifications regarding
        their own state or the state of their Power Monitor Children.
        The Power Monitor Children do not send SNMP notifications on
        their own.
     
        As discussed in [POWER-MON-REQ], the Power Monitor Parents may
        export IPFIX Flow Records [RFC5101] to a Collector.  The IPFIX
        protocol is well suited for regular time series export of
        similar information, such as the energy consumed by the Power
        Monitor Children.
     
        EDITOR'S NOTE: at this point in time, there is no draft
        specifying the IPFIX Flow Records.
     
     
     5. Architecture High Level Concepts and Scope
     
        The scope of this architecture is to enable networking and
        network-attached devices to be managed with respect to their
        energy consumption or production.  The goal is to make devices
        energy-aware.
     
        The architecture describes how to make a device aware of its
        consumption or production of energy expressed as usage in watts.
        This does not include:
     
        - Manufacturing costs in currency or environmental units
        - Embedded carbon or environmental equivalences of the device
        itself
        - Cost in currency or environmental impact to dismantle or
        recycle the device
        - Relationship to an electrical or smart grid
        - Supply chain analysis
     
     
     <Claise, et. Al>        Expires April 20, 2011            [Page 9]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
        - Conversion of the usage or production of energy to units
        expressed from the source of that energy (such as the greenhouse
        gas emissions associated with 1000kW from a diesel source).
     
        The remainder of this section describes the basic concepts of
        the architecture.  Each concept is examined in detail in
        subsequent sections.
     
        Examples are provided in a later section to show how these
        concepts can be implemented.
     
        The basic concepts are:
     
        The Power Monitor will have basic naming and informational
        descriptors to identify it in the network.
     
        A Power Monitor can be part of a Power Monitor Meter Domain.  A
        Power Monitor Meter Domain is a manageable set of devices that
        has a meter or sub-meter attached and typically corresponds to a
        power distribution point or panel.
     
        A Power Monitor can be a parent (Power Monitor Parent) or child
        (Power Monitor Child) of another Power Monitor.  This allows for
        Power Monitor Parent to aggregate power reporting and control of
        power information.
     
        Each Power Monitor can have information to allow it to be
        described in the context of the business or ultimate use.  This
        is in addition to its networked information.  This allows for
        tagging, grouping, and differentiation between Power Monitors
        for NMS.
     
        For control and universal monitoring, each Power Monitor
        implements or declares a set of known Power Levels.  The Power
        Levels are mapped to Manufacturer Power Levels that indicate the
        specific power settings for the device implementing the Power
        Monitor.
     
        When the Power Level is set, a Power Monitor may be busy at the
        request time.  The Power Monitor will set the desired level and
        then update the actual Power Level when the priority task is
        finished.  This mechanism implies two different Power Level
        variables: actual versus desired.
     
        EDITOR'S NOTE: The transition state will have to be specified.
     
     
     
     
     
     <Claise, et. Al>        Expires April 20, 2011           [Page 10]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
        Each Power Monitor will have usage information that describes
        the power information along with how that usage was obtained or
        derived.
     
        Optionally, a Power Monitor can further describe the power
        information with power quality information reflecting the
        electrical characteristics of the measurement.
     
        Optionally, a Power Monitor can provide power usage over time to
        describe energy consumption
     
        If a Power Monitor has one or more batteries, it can provide
        optional battery information as well.
     
     
     5.1. Power Monitor Information
     
        Every Power Monitor should have a unique printable name, and
        must have a unique Power Monitor index.
     
        Possible naming conventions are: textual DNS name, MAC-address
        of the device, interface ifName, or a text string uniquely
        identifying the Power Monitor.  As an example, in the case of IP
        phones, the Power Monitor name can be the device DNS name.
     
     
     5.2. Power Monitor Meter Domain
     
        Each Power Monitor must be a member of a Power Monitor Meter
        Domain.  The Power Monitor Meter Domain should map 1-1 with a
        metered or sub-metered portion of the site.  The Power Monitor
        Meter Domain must be configured on the Power Monitor Parent.
        The Power Monitor Children may inherit their domain values from
        the Power Monitor Parent or the Power Monitor Meter Domain may
        be configured directly in a Power Monitor Child.
     
     
     5.3. Power Monitor Parent and Child
     
     
        A Power Monitor Child reports its power usage to its Power
        Monitor Parent.  A Power Monitor Child has one and only one
        Power Monitor Parent.  If a Power Monitor had two parents there
        would be a risk of double-reporting the power usage in the Power
        Monitor Meter Domain. Therefore, a Power Monitor cannot be both
        a Power Monitor Parent and a Power Monitor Child at the same
        time.
     
     
     
     <Claise, et. Al>        Expires April 20, 2011           [Page 11]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
        A Power Monitor Child can be fully dependent on the Power
        Monitor Parent for its power or independent from the parent
        (such as a PC connected to a switch).  In the dependently
        powered case, the Power Monitor Parent provides power for the
        Power Monitor Child (as in the case of Power Over Ethernet
        devices).  In the independently powered case, the Power Monitor
        Child draws power from another source (typically a wall outlet).
        Since the Power Monitor Parent is not the source of power
        supply, the power usage cannot be measured at the Power Monitor
        Parent.  However, an independent Power Monitor Child reports
        Power Monitor information to the Power Monitor Parent.  The
        Power Monitor Child may listen to the power control settings
        from a Power Monitor Parent and could react to the control
        messages.  However, note that the communication between the
        Power Monitor Parent and Power Monitor Child is out of scope for
        this document.
     
        A mechanism, outside of the scope of this document, should be in
        place to verify the connectivity between the Power Monitor
        Parent and its Power Monitor Children.  If a Power Monitor Child
        is unavailable, the Power Monitor Parent must follow some rules
        to determine how long it should wait before removing the Power
        Monitor Child entry, along with all associated statistics, from
        its database.  In some situations, such as a connected building
        in which the Power Monitor Children are somewhat static, this
        removal-delay period may be long, and persistence across a Power
        Monitor Parent reload may make sense.  However, in a networking
        environment, where endpoints can come and go, there is not much
        sense in configuring a long removal timer.  In all cases, the
        removal timer or persistence must be clearly specified.
     
        Further examples of Power Monitor Parent and Child
        implementations are provided in the Implementation Scenarios
        section 11.
     
     
     5.4. Power Monitor Context
     
        Monitored power data will ultimately be collected by and
        reported from an NMS.  In order to aid in reporting and in
        differentiation between Power Monitors, each Power Monitor will
        contain information establishing its business or site context.
        A Power Monitor can provide an importance value in the range of
        1 to 100 to help differentiate a device's use or relative value
        to the site.  The importance range is from 1 (least important)
        to 100 (most important).  The default importance value is 1.
     
     
     
     
     <Claise, et. Al>        Expires April 20, 2011           [Page 12]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
        For example: A typical office environment has several types of
        phones, which can be rated according to their business impact.
        A public desk phone has a lower importance (for example, 10)
        than a business-critical emergency phone (for example, 100).  As
        another example: A company can consider that a PC and a phone
        for a customer-service engineer is more important than a PC and
        a phone for lobby use.
     
        Although network managers must establish their own ranking, the
        following is a broad recommendation:
     
          . 90 to 100 Emergency response
          . 80 to 90 Executive or business-critical
          . 70 to 79 General or Average
          . 60 to 69 Staff or support
          . 40 to 59 Public or guest
          . 1  to 39 Decorative or hospitality
     
        A Power Monitor can provide a set of keywords.  These keywords
        are a list of tags that can be used for grouping and summary
        reporting within or between Power Monitor Meter Domains.  All
        alphanumeric characters and symbols, such as #, (, $, !, and &,
        are allowed.  Potential examples are: IT, lobby, HumanResources,
        Accounting, StoreRoom, CustomerSpace, router, phone, floor2, or
        SoftwareLab.  There is no default value for a keyword.
     
        Multiple keywords can be assigned to a device.  In such cases,
        the keywords are separated by commas and no spaces between
        keywords are allowed.  For example, "HR,Bldg1,Private".
     
        Additionally, a Power Monitor can provide a "role description"
        string that indicates the purpose the Power Monitor serves in
        the network or for the site/business.  This could be a string
        describing the context the device fulfills in deployment.  For
        example, a lighting fixture in a kitchen area could have a role
        of "Hospitality Lighting" to provide context for the use of the
        device.
     
     
     5.5. Power Monitor Levels
     
        Power Levels represent universal states of power management of a
        Power Monitor.  Each Power Level corresponds to a global,
        system, and performance state in the ACPI model [ACPI].
     
     
                Level        ACPI Global/System    Power Level
                                    State               Name
     
     
     <Claise, et. Al>        Expires April 20, 2011           [Page 13]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
     
        Non-operational states:
     
                  1               G3, S5           Mech Off
                  2               G2, S5           Soft Off
                  3               G1, S4           Hibernate
                  4               G1, S3           Sleep
                  5               G1, S2           Standby
                  6               G1, S1           Ready
     
        Operational states:
                  7               G0, S0, P5       LowMinus
                  8               G0, S0, P4       Low
                  9               G0, S0, P3       MediumMinus
                 10               G0, S0, P2       Medium
                 11               G0, S0, P1       HighMinus
                 12               G0, S0, P0       High
     
                      Figure 3: ACPI / Power Level Mapping
     
        For example, a Power Monitor with a Power Level of 9 would
        indicate an operational state with MediumMinus Power Level.
     
        The Power Levels can be considered as guidelines in order to
        promote interoperability across device types.  Realistically,
        each specific feature requiring Power Levels will require a
        complete recommendation of its own.  For example, designing IP
        phones with consistent Power Levels across vendors requires a
        specification for IP phone design, along with the Power Levels
        mapping.
     
        Manufacturer Power Levels are required in some situations, such
        as when no mappings with the existing Power Levels are possible,
        or when more than the twelve specified Power Levels are
        required.
     
        A first example would be an imaginary device type, with only
        five levels: "none", "short", "tall", "grande", and "venti".
     
          Manufacturer Power Level     Respective Name
               0                           none
               1                           short
               2                           tall
               3                           grande
               4                           venti
     
                          Figure 4: Mapping Example 1
     
     
     
     <Claise, et. Al>        Expires April 20, 2011           [Page 14]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
        In the unlikely event that there is no possible mapping between
        these Manufacturer Power Levels and the proposed Power Monitor
        Power Levels, the Power Level will remain 0 throughout the MIB
        module, as displayed below.
     
           Power Level / Name       Manufacturer Power Level / Name
               0 / unknown              0 / none
               0 / unknown              1 / short
               0 / unknown              2 / tall
               0 / unknown              3 / grande
               0 / unknown              4 / venti
     
                          Figure 5: Mapping Example 2
     
        If a mapping between the Manufacturer Power Levels and the Power
        Monitor Power Levels is achievable, both series of levels must
        exist in the MIB module in the Power Monitor Parent, allowing
        the NMS to understand the mapping between them by correlating
        the Power Level with the Manufacturer Power Levels.
     
           Power Level / Name       Manufacturer Power Level / Name
               1 / Mech Off             0 / none
               2 / Soft Off             0 / none
               3 / Hibernate            0 / none
               4 / Sleep, Save-to-RAM   0 / none
               5 / Standby              0 / none
               6 / Ready                1 / short
               7 / LowMinus             1 / short
               8 / Low                  1 / short
               9 / MediumMinus          2 / tall
               10 / Medium              2 / tall
               11 / HighMinus           3 / grande
               12 / High                4 / venti
     
                          Figure 6: Mapping Example 3
     
     
        How the Power Monitor Levels are then mapped is an
        implementation choice.  However, it is recommended that the
        Manufacturer Power Levels map to the lowest applicable Power
        Levels, so that setting all Power Monitors to a Power Level
        would be conservative in terms of disabled functionality on the
        Power Monitor.
     
        A second example would be a device type, such as a dimmer or a
        motor, with a high number of operational levels.  For the sake
        of the example, 100 operational states are assumed.
     
     
     
     <Claise, et. Al>        Expires April 20, 2011           [Page 15]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
           Power Level / Name       Manufacturer Power Level / Name
               1 / Mech Off                  0 / off
               2 / Soft Off                  0 / off
               3 / Hibernate                 0 / off
               4 / Sleep, Save-to-RAM        0 / off
               5 / Standby                   1 / off
               6 / Ready                     2 / off
               7 / LowMinus                  11 / 1%
               7 / LowMinus                  12 / 2%
               7 / LowMinus                  13 / 3%
               .                             .
               .                             .
               .                             .
               8 / Low                       15 / 15%
               8 / Low                       16 / 16%
               8 / Low                       17 / 17%
               .                             .
               .                             .
               .                             .
               9 / MediumMinus               30 / 30%
               9 / MediumMinus               31 / 31%
               9 / MediumMinus               32 / 32%
               .                             .
               .                             .
               .                             .
               10 / Medium                   45 / 45%
               10 / Medium                   46 / 46%
               10 / Medium                   47 / 47%
               .                             .
               .                             .
               .                             .
               etc...
     
                          Figure 7: Mapping Example 4
     
        As specified in section 6, this architecture allows the
        configuration of the Power Level, while configuring the
        Manufacturer Power Level from the MIB directly is not possible.
     
     
     5.6. Power Monitor Usage Measurement
     
        The usage or production or power must be qualified as more than
        a value alone.  A measurement should be qualified with the
        units, magnitude, direction of power flow, and by what means the
        measurement was made (ex: Root Mean Square versus Nameplate) .
     
     
     
     
     <Claise, et. Al>        Expires April 20, 2011           [Page 16]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
        In addition, the Power Monitor should describe how it intends to
        measure usage as one of consumer, producer or meter of usage.
        Given the intent any readings can be correctly summarized or
        analyzed by an NMS.  For example metered usage reported by a
        meter and consumption usage reported by a device connected to
        that meter may naturally measure the same usage.  With the two
        measurements identified by intent a proper summarization can be
        made by an NMS.
     
        The power usage measurement should conform to the IEC 61850
        definition of unit multiplier for the SI (System International)
        units of measure.  The power usage measurement is considered an
        instantaneous usage value and does not include the usage over
        time.
     
        Measured values are represented in SI units obtained by
        BaseValue * 10 raised to the power of the scale.  For example,
        if current power usage of a Power Monitor is 3, it could be 3 W,
        3 mW, 3 KW, or 3 MW, depending on the value of the scaling
        factor
     
        In addition to knowing the usage and magnitude, it is useful to
        know how a Power Monitor usage measurement was obtained:
          . Whether the measurements were made at the device itself or
             from a remote source.
          . Description of the method that was used to measure the
             power and whether this method can distinguish actual or
             estimated values.
     
        An NMS can use this information to account for the accuracy and
        nature of the reading between different implementations.
     
        In addition to the power usage, the nameplate power rating of a
        Power Monitor is typically specified by the vendor as the
        capacity required to power the device.  Often this label is a
        conservative number and is the worst-case power draw.  While the
        actual utilization of an entity can be lower, the nameplate
        power is important for provisioning, capacity planning and
        billing.
     
     
     5.7. Optional Power Usage Quality
     
        Given a power measurement of a Power Monitor, it may in certain
        circumstances be desirable to know the power quality associated
        with that measurement.  The information model must adhere to the
        IEC 61850 7-2 standard for describing AC measurements.  In some
     
     
     
     <Claise, et. Al>        Expires April 20, 2011           [Page 17]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
        Power Monitor Domains, the power quality may not be needed,
        available, or relevant to the Power Monitor.
     
     
     5.8. Optional Energy Measurement
     
        In addition to reporting the Power Level, an approach to
        characterizing the energy demand is required.  It is well known
        in commercial electrical utility rates that demand charges can
        be on par with actual power charges, so it is useful to
        characterize the demand.  The demand can be described as the
        average energy of an Power Monitor over a time window called a
        demand interval (typically 15 minutes).  The highest peak energy
        demand measured over a time horizon, such as 1 month or 1 year,
        is often the basis for usage charges.  A single window of time
        of high usage can penalize the consumer with higher energy
        consumption charges.  However, it is relevant to measure the
        demand only when there are actual power measurements from a
        Power Monitor, and not when the power measurement is assumed or
        predicted.
     
        Several efficiency metrics can be derived and tracked with the
        demand usage data. For example:
     
          . Per-packet power costs for a networking device (router or
             switch) can be calculated by an NMS.  The packet count can
             be determined from the traffic usage in the ifTable
             [RFC2863], from the forwarding plane figure, or from the
             platform specifications.
     
          . Watt-hour power can be combined with utility energy sources
             to estimate carbon footprint and other emission statistics.
     
     
     5.9. Optional Battery Information
     
        Some Power Monitors may be running on batteries.  Therefore
        information such as the battery status (charging or
        discharging), remaining capacity, and so on, must be available.
     
     
     6. Power Monitor Children Discovery
     
        There are multiple ways that the Power Monitor Parent can
        discover its Power Monitor Children, if they are not present on
        the same physical network element:
     
     
     
     
     <Claise, et. Al>        Expires April 20, 2011           [Page 18]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
          . In case of PoE, the Power Monitor Parent automatically
             discovers a Power Monitor Child when the Child requests
             power.
          . The Power Monitor Parent and Children may run the Link
             Layer Discovery Protocol [LLDP], or any other discovery
             protocol, such as Cisco Discovery Protocol (CDP).  The
             Power Monitor Parent might even support the LLDP-MED MIB
             [LLDP-MED-MIB], which returns extra information on the
             Power Monitor Children.
          . The Power Monitor Parent may reside on a network connected
             facilities gateway.  A typical example is a converged
             building gateway, monitoring several other devices in the
             building, and serving as a proxy between SNMP and a
             protocol such as BACNET.
     
        When a Power Monitor Child supports only its own Manufacturer
        Power Levels, the Power Monitor Parent will have to discover
        those Manufacturer Power Levels.  Note that the communication
        specifications between the Power Monitor Parent and Children is
        out of the scope of this document.  This includes the
        Manufacturer Power Levels discovery, which is protocol-specific.
     
     
     7. Configuration
     
        This power management architecture allows the configuration of
        the following key parameters:
     
          . Power Monitor name: A unique printable name for the Power
             Monitor.
          . Power Monitor Role: An administratively assigned name to
             indicate the purpose a Power Monitor serves in the network.
          . Power Monitor Importance: A ranking of how important the
             Power Monitor is, on a scale of 1 to 100, compared with
             other Power Monitors in the same Power Monitor Meter
             Domain.
          . Power Monitor Keywords: A list of keywords that can be used
             to group Power Monitors for reporting or searching.
          . Power Monitor Domain: Specifies the name of a Power Monitor
             Meter Domain for the Power Monitor.
          . The Power Monitor Level: Specifies the current Power Level
             (0..12) for the Power Monitor.
          . The energy demand parameters: For example, which interval
             length to report the energy on, the number of intervals to
             keep, etc.
     
        When a Power Monitor requires a mapping with the Manufacturer
        Power Level, the Power Monitor configuration is done via the
     
     
     <Claise, et. Al>        Expires April 20, 2011           [Page 19]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
        Power Level settings, and not directly via the Manufacturer
        Power Levels, which are read-only.  Taking into account Figure
        8, where the LowMinus Power Level corresponds to three different
        Manufacturer Power Levels (11 for 1%, 12 for 2%, and 13 for 3%),
        the implication is that this architecture will not set the
        Manufacturer Power Level to one percent granularity without
        communicating over or configuring the proprietary protocol for
        this Power Monitor.
     
        This architecture uses a Power Level MIB object to set up the
        Power Level for a specific Power Monitor.  However, the Power
        Monitor might be busy executing an important task that requires
        the current Power Level for some more time.  For example, a PC
        might have to finish a backup first, or an IP phone might be
        busy with a current phone call.  Therefore a second MIB object
        contains the actual Power Level.  A difference in values between
        the two objects indicates that the Power Monitor is currently in
        Power Level transition.
     
        Interactions with established open protocols, such as Wake-up-
        on-Lan (WoL) and DASH [DASH], may require configuration in the
        Power Monitor as well, facilitating the communication between
        Power Monitor Parent and remote Power Monitor Children.
     
        Note that the communication specifications between the Power
        Monitor Parent and Children is out of the scope of this
        document.  This includes communication of power settings and
        configuration information, such as the Power Monitor Domain.
     
     
     8. Fault Management
     
        [POWER-MON-REQ] specifies some requirements about power states
        such as "the current state - the time of the last change", "the
        total time spent in each state", "the number of transitions to
        each state", etc.  Such requirements are fulfilled via the
        pmPowerLevelChange NOTIFICATION-TYPE [POWER-MON-MIB].  This SNMP
        notification is generated when the value(s) of Power Level has
        changed for the Power Monitor.
     
     
     9. IPFIX
     
     
        A push-based mechanism, such as IPFIX [RFC5101], might be
        required to export high-volume time series of energy consumption
        values, as mentioned in [POWER-MON-REQ].
     
     
     
     <Claise, et. Al>        Expires April 20, 2011           [Page 20]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
        EDITOR'S NOTE: the Working Group should decide how much of IPFIX
        should be described in this document
     
     
     10. Relationship with Other Standards Development Organizations
     
     10.1. Information Modeling
     
        This power management architecture should, as much as possible,
        reuse existing standards efforts, especially with respect to
        information modeling and data modeling [RFC3444].
     
        The data model for power, energy related objects is based on IEC
        61850.
     
        Specific examples include:
     
          . The scaling factor, which represents Power Monitor usage
             magnitude, conforms to the IEC 61850 definition of unit
             multiplier for the SI (System International) units of
             measure.
     
          . The power accuracy model is based on the ANSI and IEC
             Standards, which require that we use an accuracy class for
             power measurement.  ANSI and IEC define the following
             accuracy classes for power measurement:
     
             . IEC 62053-22  60044-1 class 0.1, 0.2, 0.5, 1  3.
     
             . ANSI C12.20 class 0.2, 0.5
     
          . The powerQualityMIB MIB module adheres closely to the IEC
             61850 7-2 standard for describing AC measurements.
     
     
     10.2. Power Levels
     
        There are twelve Power Monitor Levels.  They are subdivided into
        six operational states, and six non-operational states.  The
        lowest non-operational state is 1 and the highest is six.  Each
        non-operational state corresponds to an ACPI level [ACPI].
     
     
     
     
     
     
     
     
     <Claise, et. Al>        Expires April 20, 2011           [Page 21]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
     11. Implementation Scenarios
     
        The scope of power and energy monitoring consists of devices
        that consume power within and that are connected to a
        communications network.  These devices include:
     
        - Network devices and sub-components: Devices such as routers
        and switches and their sub-components.
     
        - Network attached endpoints: Devices that use the
        communications network, such as endpoints, PCs, and facility
        gateways that proxy energy monitor and control for commercial
        buildings or home automation.
     
        - Network attached meters or supplies: Devices that can monitor
          the electrical supply, such as smart meters or Universal
          Power Supplies (UPS) that meter and provide availability.
        -
        This section provides illustrative examples that model different
        scenarios for implementation of the Power Monitor, including
        Power Monitor Parent and Power Monitor Child relationships.
     
        Each of the scenarios below is explained in more detail in the
        Power Monitor MIB document [POWER-MON-MIB], with a mapping to
        the MIB Objects.
     
     
     Scenario 1: Switch with PoE endpoints
     
        Consider a PoE IP phone connected to a switch.  The IP phone
        draws power from the PoE switch.
     
     
     Scenario 2: Switch with PoE endpoints with further connected
        device(s)
     
        Consider the same example as in Scenario 1, but with a PC daisy-
        chained from the IP phone for LAN connectivity.  The phone draws
        power from the PoE port of the switch, while the PC draws power
        from the wall outlet.
     
     
     Scenario 3: A switch with Wireless Access Points
     
        Consider a WAP (Wireless Access Point) connected to the PoE port
        of a switch.  There are several PCs connected to the Wireless
        Access Point over Wireless protocols.  All PCs draw power from
        the wall outlets.
     
     
     <Claise, et. Al>        Expires April 20, 2011           [Page 22]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
     
        The switch port is the Power Monitor Parent for the Wireless
        Access Point (WAP) and all the PCs. But there is a distinction
        among the Power Monitor Children, as the WAP draws power from
        the PoE port of the switch and the PCs draw power from the wall
        outlet.
     
     
     Scenario 4: Network connected facilities gateway
     
        At the top of the network hierarchy of a building network is a
        gateway device that can perform protocol conversion between many
        facility management devices, such as BACNET, MODBUS, DALI, LON,
        etc.  There are power meters associated with power-consuming
        entities (Heating Ventilation & Air Conditioning - HVAC,
        lighting, electrical, fire control, elevators, etc).  The
        proposed MIB can be implemented on the gateway device.  The
        gateway can be considered as the Power Monitor Parent, while the
        power meters associated with the energy consuming entities can
        be considered as its Power Monitor Children.
     
     
     Scenario 5: Data center network
     
        A typical data center network consists of a hierarchy of
        switches.  At the bottom of the hierarchy there are servers
        mounted on a rack, and these are connected to the top-of-the-
        rack switches.  The top switches are connected to aggregation
        switches that are in turn connected to core switches.  As an
        example, Server 1 and Server 2 are connected to different switch
        ports of the top switch.
     
        The proposed MIB can be implemented on the switches.  The switch
        can be considered as the Power Monitor Parent.  The servers can
        be considered as the Power Monitor Children.
     
     Scenario 6: Building gateway device
     
        Similar scenario as the scenario 4.
     
     
     Scenario 7: Power consumption of UPS
     
        Data centers and commercial buildings can have Uninterruptible
        Power Supplies (UPS) connected to the network. The Power Monitor
        can be used to model a UPS as a Power Monitor Parent with the
        connected devices as Power Monitor Children.
     
     
     
     <Claise, et. Al>        Expires April 20, 2011           [Page 23]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
     
     Scenario 8: Power consumption of battery-based devices
     
        A PC is a typical example of a battery-based device.
     
     
     12. Security Considerations
     
        Regarding the data attributes specified here, some or all may be
        considered sensitive or vulnerable in some network environments.
        Reading or writing these attributes without proper protection
        such as encryption or access authorization may have negative
        effects on the network capabilities.
     
     
     12.1. Security Considerations for SNMP
     
        Readable objects in a MIB modules (i.e., objects with a MAX-
        ACCESS other than not-accessible) may be considered sensitive or
        vulnerable in some network environments.  It is thus important
        to control GET and/or NOTIFY access to these objects and
        possibly to encrypt the values of these objects when sending
        them over the network via SNMP.
     
        The support for SET operations in a non-secure environment
        without proper protection can have a negative effect on network
        operations.  For example:
     
          . Unauthorized changes to the Power Domain or business
             context of a Power Monitor may result in misreporting or
             interruption of power.
          . Unauthorized changes to a power level may disrupt the power
             settings of the different Power Monitors, and therefore the
             level of functionality of the respective Power Monitors.
          . Unauthorized changes to the demand history may disrupt
             proper accounting of energy usage.
     
        With respect to data transport SNMP versions prior to SNMPv3 did
        not include adequate security.  Even if the network itself is
        secure (for example, by using IPsec), there is still no secure
        control over who on the secure network is allowed to access and
        GET/SET (read/change/create/delete) the objects in these MIB
        modules.
     
        It is recommended that implementers consider the security
        features as provided by the SNMPv3 framework (see [RFC3410],
        section 8), including full support for the SNMPv3 cryptographic
        mechanisms (for authentication and privacy).
     
     
     <Claise, et. Al>        Expires April 20, 2011           [Page 24]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
     
        Further, deployment of SNMP versions prior to SNMPv3 is not
        recommended.  Instead, it is recommended to deploy SNMPv3 and to
        enable cryptographic security.  It is then a customer/operator
        responsibility to ensure that the SNMP entity giving access to
        an instance of these MIB modules is properly configured to give
        access to the objects only to those principals (users) that have
        legitimate rights to GET or SET (change/create/delete) them.
     
     
     12.2. Security Considerations for IPFIX
     
        EDITOR'S NOTE: to be completed if IPFIX is discussed in this
        document
     
     13. IANA Considerations
     
        This document has no actions for IANA.
     
     
     14. Acknowledgments
     
        The authors would like to Michael Brown for improving the text
        dramatically.
     
     
     15. References
     
     Normative References
     
     
        [RFC3410]  Case, J., Mundy, R., Partain, D., and B. Stewart,
                "Introduction and Applicability Statements for Internet
                Standard Management Framework ", RFC 3410, December
                2002.
     
        [RFC5101] B. Claise, Ed., Specification of the IP Flow
                Information Export (IPFIX) Protocol for the Exchange of
                IP Traffic Flow Information, RFC 5101, January 2008.
     
        [POWER-MON-REQ] Quittek, J., Winter, R., Dietz, T., Claise, B.,
                and M. Chandramouli, "Requirements for Power
                Monitoring", draft-quittek-power-monitoring-
                requirements-01 (work in progress), July 2010.
     
        [POWER-MON-MIB] Claise, B., Chandramouli, M., Parello, J., and
                Schoening, B., "Power and Energy Monitoring MIB",
     
     
     
     <Claise, et. Al>        Expires April 20, 2011           [Page 25]


     Internet-Draft    <Power Management Archictecure>   Octobre 2010
     
                draft-claise-energy-monitoring-mib-06, (work in
                progress), October 2010.
     
     
     Informative References
     
     
        [RFC2863]  McCloghrie, K., Kastenholz, F., "The Interfaces Group
                MIB", RFC 2863, June 2000.
     
        [RFC3444]  Pras, A., Schoenwaelder, J. "On the Differences
                between Information Models and Data Models", RFC 3444,
                January 2003.
     
        [ACPI] "Advanced Configuration and Power Interface
                Specification", http://www.acpi.info/spec30b.htm
     
     
        [LLDP]  IEEE Std 802.1AB, "Station and Media Control
                Connectivity Discovery", 2005.
     
        [LLDP-MED-MIB]  ANSI/TIA-1057, "The LLDP Management Information
                Base extension module for TIA-TR41.4 media endpoint
                discovery information", July 2005.
     
        [DASH] "Desktop and mobile Architecture for System Hardware",
                http://www.dmtf.org/standards/mgmt/dash/
     
     
     Authors' Addresses
     
      Benoit Claise
      Cisco Systems, Inc.
      De Kleetlaan 6a b1
      Diegem 1813
      BE
     
      Phone: +32 2 704 5622
      Email: bclaise@cisco.com
     
     
     
      John Parello
      Cisco Systems, Inc.
      3550 Cisco Way
      San Jose, California 95134
      US
     
     
     
     <Claise, et. Al>        Expires April 20, 2011           [Page 26]