Internet Working Group Ali Sajassi, Ed.
Internet Draft Frank Brockners
Category: Informational Cisco Systems
Dinesh Mohan, Ed.
Yetik Serbest
Expires: April 24, 2010 October 24, 2010
VPLS Interoperability with CE Bridges
draft-ietf-l2vpn-vpls-bridge-interop-06.txt
Status of this Memo
This Internet-Draft is submitted to IETF in full conformance with
the provisions of BCP 78 and BCP 79.
Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF), its areas, and its working groups. Note that
other groups may also distribute working documents as Internet-
Drafts.
Internet-Drafts are draft documents valid for a maximum of six
months and may be updated, replaced, or obsoleted by other documents
at any time. It is inappropriate to use Internet-Drafts as reference
material or to cite them other than as "work in progress."
The list of current Internet-Drafts can be accessed at
http://www.ietf.org/ietf/1id-abstracts.txt.
The list of Internet-Draft Shadow Directories can be accessed at
http://www.ietf.org/shadow.html.
Copyright and License Notice
Copyright (c) 2010 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with
respect to this document. Code Components extracted from this
document must include Simplified BSD License text as described in
Section 4.e of the Trust Legal Provisions and are provided without
warranty as described in the Simplified BSD License.
This document may contain material from IETF Documents or IETF
Sajassi, et. al. [Page 1]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
Contributions published or made publicly available before November
10, 2008. The person(s) controlling the copyright in some of this
material may not have granted the IETF Trust the right to allow
modifications of such material outside the IETF Standards Process.
Without obtaining an adequate license from the person(s) controlling
the copyright in such materials, this document may not be modified
outside the IETF Standards Process, and derivative works of it may
not be created outside the IETF Standards Process, except to format
it for publication as an RFC or to translate it into languages other
than English.
Abstract
One of the main motivations behind VPLS is its ability to provide
connectivity not only among customer routers and servers/hosts but
also among customer IEEE bridges. VPLS is expected to deliver the
same level of service that current enterprise users are accustomed
to from their own enterprise bridged networks or their Ethernet
Service Providers.
When CE devices are IEEE bridges, then there are certain issues and
challenges that need to be accounted for in a VPLS network. The
majority of these issues have been addressed in the IEEE 802.1ad
standard for provider bridges and they can be leveraged for VPLS
networks. This draft extends the PE model described in [RFC-4664]
based on IEEE 802.1ad bridge module, and illustrates a clear
demarcation between the IEEE bridge module and IETF LAN emulation
module. By doing so, it shows that the majority of interoperability
issues with CE bridges can be delegated to the 802.1ad bridge
module, thus removing the burden on the IETF LAN emulation module
within a VPLS PE.
Conventions
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in [RFC-2119].
Table of Contents
1. Introduction.................................................... 3
2. Ethernet Service Instance....................................... 4
3. VPLS-Capable PE Model with Bridge Module........................ 5
4. Mandatory Issues................................................ 7
4.1. Service Mapping............................................... 7
4.2. CE Bridge Protocol Handling................................... 9
4.3. Partial-mesh of Pseudowires.................................. 10
Sajassi, et al. [Page 2]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
4.4. Multicast Traffic............................................ 11
5. Optional Issues................................................ 12
5.1. Customer Network Topology Changes............................ 13
5.2. Redundancy................................................... 14
5.3. MAC Address Learning......................................... 16
6. Interoperability with 802.1ad Networks......................... 17
7. Acknowledgments................................................ 17
8. IANA Considerations............................................ 17
9. Security Considerations........................................ 17
10. Normative References.......................................... 18
11. Informative References........................................ 18
Authors' Addresses................................................ 19
1.
Introduction
Virtual Private LAN Service (VPLS) is a LAN emulation service
intended for providing connectivity between geographically dispersed
customer sites across MAN/WAN (over MPLS/IP) network(s), as if they
were connected using a LAN. One of the main motivations behind VPLS
is its ability to provide connectivity not only among customer
routers and servers/hosts but also among IEEE customer bridges. If
only connectivity among customer IP routers/hosts was desired, then
an IPLS solution [IPLS] could have been used. The strength of the
VPLS solution is that it can provide connectivity to both bridge and
non-bridge types of CE devices. VPLS is expected to deliver the same
level of service that current enterprise users are accustomed to
from their own enterprise bridged networks [802.1D/802.1Q] today or
the same level of service that they receive from their Ethernet
Service Providers using IEEE 802.1ad-based networks [P802.1ad] (or
its predecessor, QinQ-based network).
When CE devices are IEEE bridges, then there are certain issues and
challenges that need to be accounted for in a VPLS network. The
majority of these issues have been addressed in the IEEE 802.1ad
standard for provider bridges and they can be leveraged for VPLS
networks. This draft extends the PE model described in [RFC-4664]
based on IEEE 802.1ad bridge module and illustrates a clear
demarcation between IEEE bridge module and IETF LAN emulation
module. By doing so, it describes that the majority of
interoperability issues with CE bridges can be delegated to 802.1ad
bridge module, thus removing the burden on IETF LAN emulation module
within a VPLS PE. This document discusses these issues and wherever
possible suggests areas to be explored in rectifying these issues.
The detailed solution specification for these issues is outside of
the scope of this document.
Sajassi, et al. [Page 3]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
It also discusses interoperability issues between VPLS and IEEE
802.1ad networks when the end-to-end service spans across both types
of networks, as outlined in [RFC-4762].
This draft categorizes the CE-bridge issues into two groups: 1)
Mandatory and 2) Optional. The issues in group (1) need to be
addressed in order to ensure the proper operation of CE bridges. The
issues in group (2) would provide additional operational improvement
and efficiency and may not be required for interoperability with CE
bridges. Sections five and six discuss the mandatory and optional
issues respectively.
2.
Ethernet Service Instance
Before starting the discussion of bridging issues, it is important
to clarify the Ethernet Service definition. The term VPLS has
different meanings in different contexts. In general, VPLS is used
in the following contexts [Eth-OAM]: a) as an end-to-end bridged-LAN
service over one or more network (one of which being MPLS/IP
network), b) as an MPLS/IP network supporting these bridged LAN
services, and c) as (V)LAN emulation. For better clarity, we
differentiate between its usage as network versus service by using
the terms VPLS network and VPLS instance respectively. Furthermore,
we confine VPLS (both network and service) to only the portion of
the end-to-end network that spans across an MPLS/IP network. For an
end-to-end service (among different sites of a given customer), we
use the term "Ethernet Service Instance" or ESI.
[MFA-Ether] defines the Ethernet Service Instance (ESI) as an
association of two or more Attachment Circuits (ACs) over which an
Ethernet service is offered to a given customer. An AC can be either
a UNI or a NNI; furthermore, it can be an Ethernet interface or a
VLAN, it can be an ATM or FR VC, or it can be a PPP/HDLC interface.
If an ESI is associated with more than two ACs, then it is a
multipoint ESI. In this document, where ever the keyword ESI is
used, it means multipoint ESI, unless it is stated otherwise.
An ESI can correspond to a VPLS instance if its associated ACs are
only connected to a VPLS network or an ESI can correspond to a
Service VLAN if its associated ACs are only connected to a Provider-
Bridged network [P802.1ad]. Furthermore, an ESI can be associated
with both a VPLS instance and a Service VLAN when considering an
end-to-end service that spans across both VPLS and Provider-Bridged
networks. An ESI can span across different networks (e.g., IEEE
802.1ad and VPLS) belonging to the same or different administrative
domains.
An ESI most often represents a customer or a specific service
requested by a customer. Since traffic isolation among different
customers (or their associated services) is of paramount importance
Sajassi, et al. [Page 4]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
in service provider networks, its realization shall be done such
that it provides a separate MAC address domain and broadcast domain
per ESI. A separate MAC address domain is provided by using a
separate MAC forwarding table (e.g., FIB - also known as filtering
database [IEEE 802.1D]) per ESI (for both VPLS and IEEE 802.1ad
networks) and separate broadcast domain is provided by using a full-
mesh of pseudowires per ESI over the IP/MPLS core in a VPLS network
and/or a dedicated Service VLAN per ESI in an IEEE 802.1ad network.
3.
VPLS-Capable PE Model with Bridge Module
[RFC-4664] defines three models for VPLS-capable PE (VPLS-PE) based
on the bridging functionality that needs to be supported by the PE.
If the CE devices can be routers/hosts or IEEE bridges, the second
model from [RFC-4664] is the most suitable, and it is both adequate
to provide the VPLS level of service and consistent with the IEEE
standards for Provider Bridges [P802.1ad]. We briefly describe the
second model and then expand upon this model to show its sub-
components based on [P802.1ad] Provider Bridge model.
As described in [RFC-4664], the second model for VPLS-PE contains a
single bridge module supporting all the VPLS instances on that PE
where each VPLS instance is represented by a unique VLAN inside that
bridge module (also known as Service VLAN or S-VLAN). The bridge
module has a single "Emulated LAN" interface over which it
communicates with all VPLS forwarders and each VPLS instance is
represented by a unique S-VLAN tag. Each VPLS instance can consist
of a set of pseudowires and its associated forwarder corresponding
to a single Virtual LAN (VLAN) as depicted in Figure 1 below. Thus,
sometimes it is referred to as VLAN emulation.
+----------------------------------------+
| VPLS-capable PE model |
| +---------------+ +------+ |
| | | |VPLS-1|------------
| | |=======+ |Fwdr |------------ PWs
| | Bridge --------|--- |------------
| | | SVID-1| +------+ |
| | Module | | o |
| | | | o |
| | (802.1ad | | o |
| | bridge) | | o |
| | | | o |
| | | SVID-n| +------+ |
| | --------|---VPLS-n|-------------
| | |=======+ | Fwdr |------------- PWs
| | | ^ | |-------------
| +---------------+ | +------+ |
| | |
Sajassi, et al. [Page 5]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
+-----------------------|----------------+
|
LAN emulation (multi-access) Interface
Figure 1. VPLS-capable PE Model
Customer frames associated with a given ESI, carry the S-VLAN ID for
that ESI over the LAN emulation interface. The S-VLAN ID is stripped
before transmitting the frames over the set of pseudowires
associated with that VPLS instance (assuming raw mode PWs are used
as specified in [RFC-4448]).
The bridge module can itself consist of one or two sub-components
depending on the functionality that it needs to perform. The
following Figure 2 depicts the model for the bridge module based on
[P802.1ad].
+-------------------------------+
| 802.1ad Bridge Module Model |
| |
+---+ AC | +------+ +-----------+ |
|CE |---------|C-VLAN|------| | |
+---+ | |bridge|------| | |
| +------+ | | |
| o | S-VLAN | |
| o | | | ---> to VPLS Fwdr
| o | Bridge | |
+---+ AC | +------+ | | |
|CE |---------|C-VLAN|------| | |
+---+ | |bridge|------| | |
| +------+ | | |
+---+ AC | | | |
|CE |-----------------------| | |
+---+ | +-----------+ |
+-------------------------------+
Figure 2. The Model of 802.1ad Bridge Module
The S-VLAN bridge component is always required and it is responsible
for tagging customer frames with S-VLAN tags in the ingress
direction (from customer UNIs) and removing S-VLAN tags in the
egress direction (toward customer UNIs). It is also responsible for
running the provider's bridge protocol such as RSTP, MSTP, GVRP,
GMRP, etc. among provider bridges within a single administrative
domain.
The C-VLAN bridge component is required when the customer Attachment
Circuits are VLANs (aka C-VLANs). In such cases, the VPLS-capable PE
Sajassi, et al. [Page 6]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
needs to participate in some of the customer's bridging protocol
such as RSTP and MSTP. The reason that such participation is
required is because a customer VLAN (C-VLAN) at one site can be
mapped into a different C-VLAN at a different site or in case of
asymmetric mapping, a customer Ethernet port at one site can be
mapped into a customer VLAN (or group of C-VLANs) at a different
site.
The C-VLAN bridge component does service selection and
identification based on C-VLAN tags. Each frame from the customer
device is assigned to a C-VLAN and presented at one or more internal
port-based interfaces, each supporting a single service instance
that the customer desires to carry that C-VLAN. Similarly frames
from the provider network are assigned to an internal interface or
'LAN' (e.g, between C-VLAN and S-VLAN components) on the basis of
the S-VLAN tag. Since each internal interface supports a single
service instance, the S-VLAN tag can be, and is, removed at this
interface by the S-VLAN bridge component. If multiple C-VLANs are
supported by this service instance (e.g., VLAN bundling or port-
based), then the frames will have already been tagged with C-VLAN
tags. If a single C-VLAN is supported by this service instance
(e.g., VLAN-based), then the frames will not have been tagged with a
C-VLAN tag since C-VLAN can be derived from the S-VLAN (e.g., one to
one mapping). The C-VLAN aware bridge component applies a port VLAN
ID (PVID) to untagged frames received on each internal 'LAN',
allowing full control over the delivery of frames for each C-VLAN
through the Customer UNI Port.
4.
Mandatory Issues
4.1.
Service Mapping
Different Ethernet AC types can be associated with a single Ethernet
Service Instance (ESI). For example, an ESI can be associated with
only physical Ethernet ports, VLANs, or a combination of the two
(e.g., one end of the service could be associated with physical
Ethernet ports and the other end could be associated with VLANs). In
[RFC-4762], unqualified and qualified learning are used to refer to
port-based and VLAN-based operation respectively and [RFC-4762] does
not describe the possible mappings between different types of
Ethernet ACs (e.g., 802.1D, 802.1Q or 802.1ad frames). In general,
the mapping of a customer port or VLAN to a given service instance
is a local function performed by the local PE and the service
provisioning shall accommodate it. In other words, there is no
reason to restrict and limit an ESI to have only port-based ACs or
to have only VLAN-based ACs. [P802.1ad] allows for each customer AC
(either a physical port, or a VLAN, or a group of VLANs) to be
mapped independently to an ESI which provides better service
offering to Enterprise customers. For better and more flexible
Sajassi, et al. [Page 7]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
service offerings and for interoperability purposes between VPLS and
802.1ad networks, it is imperative that both networks offer the same
capabilities in terms of customer ACs mapping to the customer
service instance.
The following table lists possible mappings that can exist between
customer ACs and its associated ESI - this table is extracted from
[MFA-Ether]. As it can be seen, there are several possible ways to
perform such mapping. In the first scenario, it is assumed that an
Ethernet physical port only carries untagged traffic and all the
traffic is mapped to the corresponding service instance or ESI. This
is referred to as "port-based with untagged traffic". In the second
scenario, it is assumed that an Ethernet physical port carries both
tagged and untagged traffic and all that traffic is mapped to the
corresponding service instance or ESI. This is referred to as "port-
based with tagged and untagged traffic". In the third scenario, it
is assumed that only a single VLAN is mapped to the corresponding
service instance or ESI (referred to as VLAN-based). Finally, in the
fourth scenario, it is assumed that a group of VLANs from the
Ethernet physical interface is mapped to the corresponding service
instance or ESI.
===================================================================
Ethernet I/F & Associated Service Instance(s)
-------------------------------------------------------------------
Port-based Port-based VLAN-based VLAN
untagged tagged & bundling
untagged
-------------------------------------------------------------------
Port-based Y N Y(Note-1) N
untagged
Port-based N Y Y(Note-2) Y
tagged &
untagged
VLAN-based Y(Note-1) Y(Note-2) Y Y(Note-3)
VLAN N Y Y(Note-3) Y
Bundling
===================================================================
Note-1: In this asymmetric mapping scenario, it is assumed that the
CE device with "VLAN-based" AC is a device capable of supporting
[802.1Q] frame format.
Note-2: In this asymmetric mapping scenario, it is assumed that the
CE device with "VLAN-based" AC is a device that can support
Sajassi, et al. [Page 8]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
[P802.1ad] frame format because it will receive Ethernet frames with
two tags; where the outer tag is S-VLAN and the inner tag is C-VLAN
received from "port-based" AC. One application example for such CE
device is in a BRAS for DSL aggregation over Metro Ethernet network.
Note-3: In this asymmetric mapping scenario, it is assumed that the
CE device with "VLAN-based" AC can support the [P802.1ad] frame
format because it will receive Ethernet frames with two tags; where
the outer tag is S-VLAN and the inner tag is C-VLAN received from
"VLAN bundling" AC.
If a PE uses an S-VLAN tag for a given ESI (either by adding an S-
VLAN tag to customer traffic or by replacing a C-VLAN tag with a S-
VLAN tag), then the frame format and EtherType for S-VLAN SHALL
adhere to [P802.1ad].
As mentioned before, the mapping function between the customer AC
and its associated ESI is a local function and thus when the AC is a
single customer VLAN, it is possible to map different customer VLANs
at different sites to a single ESI without coordination among those
sites.
When a port-based mapping or a VLAN-bundling mapping is used, then
the PE may use an additional S-VLAN tag to mark the customer traffic
received over that AC as belonging to a given ESI. If the PE uses
the additional S-VLAN tag, then in the opposite direction the PE
SHALL strip the S-VLAN tag before sending the customer frames over
the same AC. However, when VLAN-mapping mode is used at an AC and if
the PE uses S-VLAN tag locally, then if the Ethernet interface is a
UNI, the tagged frames over this interface SHALL have a frame format
based on [802.1Q] and the PE SHALL translate the customer tag (C-
VLAN) into the provider tag (S-VLAN) upon receiving a frame from the
customer and in the opposite direction, the PE shall translate from
provider frame format (802.1ad) back to customer frame format
(802.1Q).
All the above asymmetric services can be supported via the PE model
with the bridge module depicted in Figure 2 (based on [802.1ad]).
4.2.
CE Bridge Protocol Handling
When a VPLS-capable PE is connected to a CE bridge, then depending
on the type of Attachment Circuit, different protocol handling may
be required by the bridge module of the PE. [P802.1ad] states that
when a PE is connected to a CE bridge, then the service offered by
the PE may appear to specific customer protocols running on the CE
in one of the four ways:
Sajassi, et al. [Page 9]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
a) Transparent to the operation of the protocol among CEs of
different sites using the service provided, appearing as an
individual LAN without bridges; or,
b) Discarding frames, acting as a non-participating barrier to the
operation of the protocol; or,
c) Peering, with a local protocol entity at the point of provider
ingress and egress, participating in and terminating the
operation of the protocol; or,
d) Participation in individual instances of customer protocols.
All the above CE bridge protocol handling can be supported via the
PE model with the bridge module depicted in figure-2 (based on
[802.1ad]). For example, when an Attachment Circuit is port-based,
then the bridge module of the PE can operate transparently with
respect to the CE's RSTP/MSTP protocols (and thus no C-VLAN
component is required for that customer UNI). However, when an
Attachment Circuit is VLAN-based (either VLAN-based or VLAN
bundling), then the bridge module of the PE needs to peer with the
RSTP/MSTP protocols running on the CE (and thus the C-VLAN bridge
component is required). In other words, when the AC is VLAN-based,
then protocol peering between CE and PE devices may be needed. There
are also protocols that require peering but are independent from the
type of Attachment Circuit. An example of such protocol is the link
aggregation protocol [802.3ad]; however, this is a media-dependent
protocol as its name implies.
[P802.1ad] reserves a block of 16 MAC addresses for the operation of
C-VLAN and S-VLAN bridge components and it shows which of these
reserved MAC addresses are only for C-VLAN bridge component and
which ones are only for S-VLAN bridge component and which ones apply
to both C-VLAN and S-VLAN components.
4.3.
Partial-mesh of Pseudowires
A VPLS service depends on a full mesh of pseudowires, so a
pseudowire failure reduces the underlying connectivity to a partial
mesh and this can have adverse effects on the VPLS service. If the
CE devices belonging to an ESI are routers running link state
routing protocols that use LAN procedures over that ESI, then a
partial-mesh of PWs can result in "black holing" traffic among the
selected set of routers. And if the CE devices belonging to an ESI
are IEEE bridges, then a partial-mesh of PWs can cause broadcast
storms in the customer and provider networks. Furthermore, it can
cause multiple copies of a single frame to be received by the CE
and/or PE devices. Therefore, it is of paramount importance to be
able to detect PW failure and to take corrective action to prevent
creation of partial-mesh of PWs.
Sajassi, et al. [Page 10]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
When the PE model depicted in Figure 2 is used, then [P802.1ag]
procedures could be used for detection of partial-mesh of PWs.
[p802.1ag] defines a set of procedures for fault detection,
verification, isolation, and notification per ESI.
The fault detection mechanism of [p8021.ag] can be used to perform
connectivity check among PEs belonging to a given VPLS instance. It
checks the integrity of a service instance end-to-end within an
administrative domain - e.g., from one AC at one end of the network
to another AC at the other end of the network. Therefore, its path
coverage includes bridge module within a PE and it is not limited to
just PWs. Furthermore, [P802.1ag] operates transparently over the
full-mesh of PWs for a given service instance since it operates at
the Ethernet level (and not at PW level). It should be noted that
since a PW consists of two uni-directional LSPs, then one direction
can fail independently of the other. Even in this case, the
procedures of [p802.1ag] can provide a consistent view of the full-
mesh to the participating PEs by relying on remote defect indication
(RDI).
Another, less preferred, option is to define a procedure for
detection of partial mesh in which each PE keeps track of the status
of PW Endpoint Entities (EEs - e.g., VPLS forwarders) for itself as
well as the ones reported by other PEs. Therefore, upon a PW
failure, the PE that detects the failure not only takes notice
locally but it notifies other PEs belonging to that service instance
of such failure so that all the participant PEs have a consistent
view of the PW mesh. Such a procedure is for the detection of
partial mesh per service instance and in turn it relies on
additional procedure for PW failure detection such as BFD or VCCV.
Given that there can be tens (or even hundreds) of thousands of PWs
in a PE, there can be scalability issues with such fault
detection/notification procedures.
4.4.
Multicast Traffic
VPLS follows a centralized model for multicast replication within an
ESI. VPLS relies on ingress replication. The ingress PE replicates
the multicast packet for each egress PE and sends it to the egress
PE using PtP PW over a unicast tunnel. VPLS operates on an overlay
topology formed by the full mesh of pseudo-wires. Thus, depending on
the underlying topology, the same datagram can be sent multiple
times down the same physical link. VPLS currently does not offer any
mechanisms to restrict the distribution of multicast or broadcast
traffic of an ESI throughout the network causing an additional
burden on the ingress PE through unnecessary packet replication,
causing additional load on the MPLS core network, and causing
additional processing at the receiving PE where extraneous multicast
packets are discarded.
Sajassi, et al. [Page 11]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
One possible approach, to delivering multicast more efficiently over
a VPLS network, is to include the use of IGMP snooping in order to
send the packet only to the PEs that have receivers for that
traffic, rather than to all the PEs in the VPLS instance. If the
customer bridge or its network has dual-home connectivity, then for
proper operation of IGMP snooping, the PE must generate a "General
Query" over that customer's UNIs upon receiving a customer topology
change notification as described in Section 7 of [RFC-4541]. A
"General Query" by the PE results in proper registration of the
customer multicast MAC address(s) at the PE when there is customer
topology change. It should be noted that IGMP snooping provides a
solution for IP multicast packets and is not applicable to general
multicast data.
Using the IGMP-snooping as described, the ingress PE can select a
sub-set of PWs for packet replication; therefore, avoiding sending
multicast packets to the egress PEs that don't need them. However,
the replication is still performed by the ingress PE. In order to
avoid, replication at the ingress PE, one may want to use multicast
distribution trees (MDTs) in the provider core network; however,
this brings with it some potential pitfalls. If the MDT is used for
all multicast traffic of a given customer, then this results in
customer multicast and unicast traffic being forwarded on different
PWs and even on a different physical topology within the provider
network. This is a serious issue for customer bridges because
customer BPDUs, which are multicast data, can take a different path
through the network than the unicast data. Situations might arise
where either unicast OR multicast connectivity is lost. If unicast
connectivity is lost, but multicast forwarding continues to work,
the customer spanning tree would not take notice which results in
loss of its unicast traffic. Similarly, if multicast connectivity is
lost, but unicast is working, then the customer spanning tree will
activate the blocked port which may result in a loop within the
customer network. Therefore, the MDT cannot be used for both
customer multicast control and data traffic. If it is used, it
should only be limited to customer data traffic. However, there can
be a potential issue even when it is used for customer data traffic
since the MDT doesn't fit the PE model described in Figure 1 (it
operates independently from the full-mesh of PWs that correspond to
an S-VLAN). It is also not clear how CFM procedures (802.1ag) used
for ESI integrity check (e.g., per service instance) can be applied
to check the integrity of the customer multicast traffic over the
provider MDT. Because of these potential issues, the specific
applications of the provider MDT to customer multicast traffic shall
be documented and its limitations be clearly specified.
5.
Optional Issues
Sajassi, et al. [Page 12]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
5.1.
Customer Network Topology Changes
A single CE or a customer network can be connected to a provider
network using more than one User-Network Interface (UNI).
Furthermore, a single CE or a customer network can be connected to
more than one provider network. [RFC-4665] provides some examples of
such customer network connectivity that are depicted in Figure 3
below. Such network topologies are designed to protect against the
failure or removal of network components from the customer network
and it is assumed that the customer leverages the spanning tree
protocol to protect against these cases. Therefore, in such
scenarios, it is important to flush customer MAC addresses in the
provider network upon the customer topology change to avoid black
holing of customer frames.
+----------- +---------------
| |
+------+ +------+ +------+ +------+
| CE |-----| PE | | CE |-----| PE |
|device| |device| |device| |device| SP network
+------+\ +------+ +------+\ +------+
| \ | | \ |
|Back \ | |Back \ +---------------
|door \ | SP network |door \ +---------------
|link \ | |link \ |
+------+ +------+ +------+ +------+
| CE | | PE | | CE | | PE |
|device|-----|device| |device|-----|device| SP network
+------+ +------+ +------+ +------+
| |
+------------ +---------------
(a) (b)
Figure 3. Combination of Dual-Homing and Backdoor Links for CE
Devices
The customer networks use their own instances of the spanning tree
protocol to configure and partition their active topology, so that
the provider connectivity doesn't result in a data loop.
Reconfiguration of a customer's active topology can result in the
apparent movement of customer end stations from the point of view of
the PEs. However, the requirement for mutual independence of the
distinct ESIs that can be supported by a single provider spanning
tree active topology does not permit either the direct receipt of
provider topology change notifications from the CEs or the use of
received customer spanning tree protocol topology change
notifications to stimulate topology change signaling on a provider
spanning tree.
Sajassi, et al. [Page 13]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
To address this issue, [P802.1ad] requires that customer topology
change notification to be detected at the ingress of the S-VLAN
bridge component and the S-VLAN bridge transmits a Customer Change
Notification (CCN) message with the S-VLAN ID associated with that
service instance and a destination MAC address as specified in the
block of 16 reserved multicast MAC addresses. Upon receiving the
CCN, the provider bridge will flush all the customer MAC addresses
associated with that S-VLAN ID on all the provider bridge interfaces
except the one that the CCN message is received from.
Based on the provider bridge model depicted in Figure 1, there are
two methods of propagating the CCN message over the VPLS network.
The first method is to translate the in-band CCN message into an
out-of-band "MAC Address Withdrawal" message as specified in [RFC-
4762] and the second method is to treat the CCN message as customer
data and pass it transparently over the set of PWs associated with
that VPLS instance. The second method is recommended because of ease
of interoperability between the bridge and the LAN emulation modules
of the PE.
5.2.
Redundancy
[RFC-4762] talks about dual-homing of a given u-PE to two n-PEs over
a provider MPLS access network to provide protection against link
and node failure - e.g., in case the primary n-PE fails or the
connection to it fails, then the u-PE uses the backup PWs to reroute
the traffic to the backup n-PE. Furthermore, it discusses the
provision of redundancy when a provider Ethernet access network is
used and how any arbitrary access network topology (not just limited
to hub-and-spoke) can be supported using the provider's MSTP
protocol and how the provider MSTP for a given access network can be
confined to that access network and operate independently from MSTP
protocols running in other access networks.
In both types of redundancy mechanism (Ethernet versus MPLS access
networks), only one n-PE is active for a given VPLS instance at any
time. In case of an Ethernet access network, core-facing PWs (for a
VPLS instance) at the n-PE are blocked by the MSTP protocol;
whereas, in case of a MPLS access network, the access-facing PW is
blocked at the u-PE for a given VPLS instance.
Sajassi, et al. [Page 14]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
-------------------------+ Provider +-----------------------
. Core .
+------+ . . +------+
| n-PE |======================| n-PE |
Provider | (P) |---------\ /-------| (P) | Provider
Access +------+ ._ \ / . +------+ Access
Network . \/ . Network
(1) +------+ . /\ . +------+ (2)
| n-PE |----------/ \--------| n-PE |
| (B) |----------------------| (B) |_
+------+ . . +------+
. .
------------------------+ +-----------------------
Figure 4. Bridge Module Model
Figure 4 shows two provider access networks each with two n-PEs
where the n-PEs are connected via a full mesh of PWs for a given
VPLS instance. As shown in the figure, only one n-PE in each access
network is serving as a Primary PE (P) for that VPLS instance and
the other n-PE is serving as the backup PE (B). In this figure, each
primary PE has two active PWs originating from it. Therefore, when a
multicast, broadcast, and unknown unicast frame arrives at the
primary n-PE from the access network side, the n-PE replicates the
frame over both PWs in the core even though it only needs to send
the frames over a single PW (shown with "==" in Figure 4) to the
primary n-PE on the other side. This is an unnecessary replication
of the customer frames that consumes core-network bandwidth (half of
the frames get discarded at the receiving n-PE). This issue gets
aggravated when there are more than two n-PEs per provider access
network - e.g., if there are three n-PEs or four n-PEs per access
network, then 67% or 75% of core-BW for multicast, broadcast and
unknown unicast are respectively wasted.
Therefore, it is recommended to have a protocol among n-PEs that can
disseminate the status of PWs (active or blocked) among themselves
and furthermore to have it tied up with the redundancy mechanism
such that per VPLS instance the status of active/backup n-PE gets
reflected on the corresponding PWs emanating from that n-PE.
The above discussion was centered on the lack of efficiency with
regards to packet replication over MPLS core network for current
VPLS redundancy mechanism. Another important issue to consider is
the interaction between customer and service provider redundancy
mechanisms especially when customer devices are IEEE bridges. If CEs
are IEEE bridges, then they can run RSTP/MSTP protocols, RSTP
convergence and detection time is much faster than its predecessor
(IEEE 802.1D STP which is obsolete). Therefore, if the provider
network offers VPLS redundancy mechanism, then it should provide
transparency to the customer's network during a failure within its
Sajassi, et al. [Page 15]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
network - e.g., the failure detection and recovery time within the
service provider network to be less than the one in the customer
network. If this is not the case, then a failure within the provider
network can result in unnecessary switch-over and temporary
flooding/loop within the customer's network that is dual homed.
5.3.
MAC Address Learning
When customer devices are routers, servers, or hosts, then the
number of MAC addresses per customer sites is very limited (most
often one MAC address per CE). However, when CEs are bridges, then
there can be many customer MAC addresses (e.g., hundreds of MAC
addresses) associated with each CE.
[P802.1ad] has devised a mechanism to alleviate MAC address learning
within provider Ethernet networks that can equally be applied to
VPLS networks. This mechanism calls for disabling MAC address
learning for an S-VLAN (or a service instance) within a provider
bridge (or PE) when there is only one ingress and one egress port
associated with that service instance on that PE. In such cases,
there is no need to learn customer MAC addresses on that PE since
the path through that PE for that service instance is fixed. For
example, if a service instance is associated with four CEs at four
different sites, then the maximum number of provider bridges (or
PEs), that need to participate in that customer MAC address
learning, is only three regardless of how many PEs are in the path
of that service instance. This mechanism can reduce the number of
MAC addresses learned in a H-VPLS with QinQ access configuration.
If the provider access network is of type Ethernet (e.g., IEEE
802.1ad-based network), then the MSTP protocol can be used to
partition the access network into several loop-free spanning tree
topologies where Ethernet service instances (S-VLANs) are
distributed among these tree topologies. Furthermore, GVRP can be
used to limit the scope of each service instance to a subset of its
associated tree topology (and thus limiting the scope of customer
MAC address learning to that sub-tree). Finally, the MAC address
disabling mechanism (described above) can be applied to that sub-
tree, to further limit the number of nodes (PEs) on that sub-tree
that need to learn customer MAC addresses for that service instance.
Furthermore, [p802.1ah] provides the capability of encapsulating
customers' MAC addresses within the provider MAC header. A u-PE
capable of this functionality can reduce the number of MAC addressed
learned significantly within the provider network for H-VPLS with
QinQ access as well as H-VPLS with MPLS access.
Sajassi, et al. [Page 16]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
6.
Interoperability with 802.1ad Networks
[RFC-4762] discusses H-VPLS provider-network topologies with both
Ethernet [P802.1ad] as well as MPLS access networks. Therefore, it is
important to ensure seamless interoperability between these two types
of networks.
Provider bridges as specified in [P802.1ad] are intended to operate
seamlessly with customer bridges and provide the required services.
Therefore, if a PE is modeled based on Figures 1 and 2 which includes
a [802.1ad] bridge module, then it should operate seamlessly with
Provider Bridges given that the issues discussed in this draft have
been taken into account.
7.
Acknowledgments
The authors would like to thank Norm Finn and Samer Salam for their
comments and valuable feedbacks.
8.
IANA Considerations
This document has no actions for IANA.
9.
Security Considerations
In addition to the security issues described in [RFC-4762], the
following considerations apply:
- When a CE that is a customer bridge is connected to the VPLS
network, it may be desirable to secure the end-to-end communication
between the customer bridge nodes across the VPLS network. This can
be accomplished by running [802.1AE] MAC Security between the C-VLAN
components of the customer bridges. In this case, the VPLS PEs must
ensure transparent delivery of the encryption/security protocol
datagrams using the Bridge Group Address [802.1ad].
- When a CE that is a customer bridge is connected to the VPLS
network, it may be desirable to secure the communication between the
customer bridge and its directly connected PE. If the PE is modeled
to include a [802.1ad] bridge module, then this can be achieved by
running MAC Security between the customer bridge and the S-VLAN
Component of the VPLS PE as described in section 7.7.2 of [802.1AX].
- When and 802.1ad network is connected to a VPLS network, it is
possible to secure the NNI between the two networks using the
procedures of [802.1AE] and [802.1AX] between the S-VLAN Components
Sajassi, et al. [Page 17]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
of the Provider Edge Bridge and the VPLS PE connecting to it, as
long as the PE is modeled to include a [802.1ad] bridge module.
10.
Normative References
[RFC-2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119, March 1997.
[RFC-4762] Lasserre, M. and et al, "Virtual Private LAN Services
over MPLS", RFC 4762, January 2007
[P802.1ad] IEEE Draft P802.1ad/D2.4 "Virtual Bridged Local Area
Networks: Provider Bridges", Work in progress, September 2004
[P802.1ag] IEEE Draft P802.1ag/D0.1 "Virtual Bridge Local Area
Networks: Connectivity Fault Management", Work in Progress, October
2004
11.
Informative References
[RFC-4665] Agustyn, W. et al, "Service Requirements for Layer-2
Provider Provisioned Virtual Provider Networks", RFC 4665, September
2006
[RFC-4664] Andersson, L. and et al, "Framework for Layer 2 Virtual
Private Networks (L2VPNs)", RFC 4664, September 2006
[IPLS] Shah, H. and et al, "IP-Only LAN Service (IPLS)", draft-ietf-
l2vpn-ipls-09.txt, work in progress, February 2009
[MFA-Ether] Sajassi, A. and et al, "Ethernet Service Interworking
Over MPLS", Work in Progress, September 2004
[RFC-4448] "Encapsulation Methods for Transport of Ethernet Frames
Over IP/MPLS Networks", RFC 4448, April 2006
[802.1D-REV] IEEE Std. 802.1D-2003 "Media Access Control (MAC)
Bridges".
[802.1Q] IEEE Std. 802.1Q-2003 "Virtual Bridged Local Area
Networks".
[RFC-4541] Christensen, M. and et al, "Considerations for IGMP and
MLD Snooping Switches", Work in progress, May 2004
Sajassi, et al. [Page 18]
Internet Draft draft-ietf-l2vpn-vpls-bridge-interop.txt October 2010
[Eth-OAM] Dinesh Mohan, Ali Sajassi, and et al, "L2VPN OAM
Requirements and Framework", draft-ietf-l2vpn-oam-req-frmk-10.txt,
Work in progress, November 2010
Authors' Addresses
Ali Sajassi
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134
Email: sajassi@cisco.com
Yetik Serbest
SBC Labs
9505 Arboretum Blvd.
Austin, TX 78759
Email: yetik_serbest@labs.sbc.com
Frank Brockners
Cisco Systems, Inc.
Hansaallee 249
40549 Duesseldorf
Germany
Email: fbrockne@cisco.com
Dinesh Mohan
Nortel Networks
3500 Carling Ave
Ottawa, ON K2H8E9
Email: mohand@nortel.com
Sajassi, et al. [Page 19]