Network Working Group C. Jennings
Internet-Draft Cisco
Intended status: Experimental October 24, 2010
Expires: April 27, 2011
Media Type for Sensor Markup Language (SENML)
draft-jennings-senml-04
Abstract
This specification defines media types for representing simple sensor
measurements in JSON. A simple sensor, such as a temperature sensor,
could use this media type in protocols such as HTTP to transport the
values of a sensor.
Status of this Memo
This Internet-Draft is submitted in full conformance with the
provisions of BCP 78 and BCP 79.
Internet-Drafts are working documents of the Internet Engineering
Task Force (IETF). Note that other groups may also distribute
working documents as Internet-Drafts. The list of current Internet-
Drafts is at http://datatracker.ietf.org/drafts/current/.
Internet-Drafts are draft documents valid for a maximum of six months
and may be updated, replaced, or obsoleted by other documents at any
time. It is inappropriate to use Internet-Drafts as reference
material or to cite them other than as "work in progress."
This Internet-Draft will expire on April 27, 2011.
Copyright Notice
Copyright (c) 2010 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
the Trust Legal Provisions and are provided without warranty as
described in the Simplified BSD License.
Jennings Expires April 27, 2011 [Page 1]
Internet-Draft Sensor Markup October 2010
Table of Contents
1. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. Requirements and Design Goals . . . . . . . . . . . . . . . . 3
3. Terminology . . . . . . . . . . . . . . . . . . . . . . . . . 4
4. Semantics . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5. Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.1. Simple Example . . . . . . . . . . . . . . . . . . . . . . 6
5.2. Complex Example . . . . . . . . . . . . . . . . . . . . . 6
6. Usage Considerations . . . . . . . . . . . . . . . . . . . . . 7
7. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 8
7.1. Units Registry . . . . . . . . . . . . . . . . . . . . . . 8
7.2. Media Type Registration . . . . . . . . . . . . . . . . . 11
7.2.1. senml+json Media Type Registration . . . . . . . . . . 11
8. Security Considerations . . . . . . . . . . . . . . . . . . . 12
9. Acknowledgement . . . . . . . . . . . . . . . . . . . . . . . 12
10. References . . . . . . . . . . . . . . . . . . . . . . . . . . 13
10.1. Normative References . . . . . . . . . . . . . . . . . . . 13
10.2. Informative References . . . . . . . . . . . . . . . . . . 13
Author's Address . . . . . . . . . . . . . . . . . . . . . . . . . 14
Jennings Expires April 27, 2011 [Page 2]
Internet-Draft Sensor Markup October 2010
1. Overview
Connecting sensors to the internet is not new, and there have been
many protocols designed to facilitate it. This specification defines
new media types for carrying simple sensor information in a protocol
such as HTTP or CoAP[I-D.ietf-core-coap]. This format was designed
so that processors with very limited capabilities could easily encode
a sensor reading into the media type, while at the same time a server
parsing the data could relatively efficiently collect a large number
of sensor readings. There are many types of more complex
measurements and readings that this media type would not be suitable
for. A decision was made not to carry most of the meta data about
the sensor in this media type to help reduce the size of the data and
improve efficiency in decoding.
JSON[RFC4627] was selected as a basis for the encoding as it
represents a widely understood way of encoding data that is popular
in current web based APIs and represents reasonable trade-offs
between extensibility, simplicity, and efficiency.
The data is structured as a single JSON object (with attributes) that
contains an array of measurements. Each measurement is a JSON object
that has attributes such as a unique identifier for the sensor, the
time the measurement was made, and the current value. For example,
the following shows a measurement from a temperature gauge in JSON
syntax.
{"m":[{ "n": "0017f202a5c5-Temp", "v":23.5, "u":"degC" }]}
In the example above, the array in the object has a single
measurement for a sensor named "0017f202a5c5-Temp" with a temperature
of 23.5 degrees Celsius.
2. Requirements and Design Goals
The design goal is to be able to send simple sensor measurements in
small packets on mesh networks from large numbers of constrained
devices. Keeping the total size under 80 bytes makes this easy to
use on a wireless mesh network. It is always difficult to define
what small code is, but there is a desire to be able to implement
this in roughly 1 KB of flash on a 8 bit microprocessor. Experience
with Google power meter and other large scale deployments has
indicated strongly that the solution needs to support allowing
multiple measurements to be batched into a single HTTP request. This
"batch" upload capability allows the server side to efficiently
support a large number of devices. The multiple measurements could
be from multiple related sensors or from the same sensor but at
Jennings Expires April 27, 2011 [Page 3]
Internet-Draft Sensor Markup October 2010
different times.
3. Terminology
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in RFC 2119 [RFC2119].
4. Semantics
Each media type caries a single JSON object that represents a set of
measurements. This object contains several optional attributes
described below and a mandatory array of one or more measurements.
bn: This is a base name string that is perpended to the names found
in the measurements. This attribute is optional.
bt: A base time that is added to the time found in a measurement.
This attribute is optional.
ver: Version number of media type format. This attribute is
optional positive integer and defaults to 1 if not present.
m: Array of measurements. Mandatory and there must be at least one
measurement in the array.
Each measurement contains several attributes, some of which are
optional and some of which are mandatory.
n: Name of sensor. When appended to the "bn" attribute, this must
result in a globally unique identifier for the sensor.
u: Units for the sensor value. Optional. Acceptable values are
specified in Section 7.1
v: Value of the sensor. Optional if an s value is present, otherwise
required.
s: Integrated sum of the sensor values over time. Optional. This
attribute is in the units specified in the u value multiplied by
seconds.
t: Time when measurement was made. Optional.
unc: The uncertainty in the measurement, that uses the same units as
the base; if absent, the value is unknown (i.e., don't assume that
this is zero). Optional.
c: The confidence of the measurement, as a probability between 0.0
and 1.0; if absent, this can be considered approximately 1.
Optional.
Jennings Expires April 27, 2011 [Page 4]
Internet-Draft Sensor Markup October 2010
ut Update time. A time in seconds that represents the maximum time
before this sensor will provide an updated reading. This can be
used to detect the failure of sensors or communications path from
the sensor. Optional.
Open Issue: Ongoing conversations around Privacy and tags. Should
there be a base version of unc & c?
The bt, v, s, and t attributes are floating point numbers. Systems
receiving measurements MUST be able to process the range of numbers
that are representable as an IEEE double-precision floating-point
numbers [IEEE.754.1985]. The number of significant digits in any
measurement is not relevant, so a reading of 1.1 has exactly the same
semantic meaning as 1.10. If the value has an exponent, the "e" MUST
be in lower case. The mantissa SHOULD be less than 19 characters
long and the exponent SHOULD be less than 5 characters long. This
allows time values to have better than micro second precision over
the next 100 years.
Systems reading one of the JSON objects MUST check for the ver
attribute. If this value is a version number larger than the version
which system understands, the system SHOULD NOT use this JSON object.
This allows the version number to indicate that the object contains
mandatory to understand attributes. New version numbers can only be
defined in RFC which updates this specification or it successors.
The n value is concatenated to the bn value to get the name of the
sensor. The resulting name needs to uniquely identity and
differentiate the sensor from all others. If the name contains 48
bits of random material, or 48 bits of material that is procedurally
assigned in a unique way, it is considered to be good enough
uniqueness. One way to achieve this uniqueness is to include a
EUI-48 identifier (A MAC address) or some other 48 bit identifier
that is guaranteed uniqueness (such as a 1-wire address) that is
assigned to the device. UUIDs [RFC4122] are another way to generate
a unique name.
The resulting concatenated name MUST consist only of characters out
of the set "A" to "Z", "a" to "z", "0" to "9", "-", ":", ".", or "_"
and it MUST start with a character out of the set "A" to "Z", "a" to
"z", or "0" to "9". This restricted character set was chosen so that
these names can be directly used as in other types of URI including
segments of an HTTP path with no special encoding. [RFC5952]
contains advice on encoding an IPv6 address in a name.
If either the bt or t value is missing, the missing attribute is
considered to have a value of zero. The bt and t values are added
together to get the time of measurement. A time of zero indicates
Jennings Expires April 27, 2011 [Page 5]
Internet-Draft Sensor Markup October 2010
that the sensor does not know the absolute time and the measurement
was made roughly "now". A negative value is used to indicate seconds
in the past from roughly "now". A positive value is used to indicate
the number of seconds, excluding leap seconds, since the start of the
year 1970 in UTC .
Open Issue: Should this be atomic seconds instead of "Unix" style
time?
Open Issue: What about NaN and Infinity in the floating point
numbers?
Open Issue: Do we need nanosecond precision for the t value? What
device would know that?
5. Syntax
All of the data is UTF-8, but since this is for machine to machine
communications on constrained systems, only characters with code
points between U+0001 and U+007F are allowed which corresponds to the
ASCII[RFC0020] subset of UTF-8.
The contents MUST consist of exactly one JSON object as specified by
[RFC4627]. This object MAY contain a "bn" attribute with a value of
type string. This object MAY contain a "bt" attribute with a value
of type number. The object MAY contain other attribute value pairs.
The object MUST contain exactly one "m" attribute with a value of
type array. The array MUST have one or more measurement objects.
Inside each measurement object the "n" and "u" attribute are of type
string and the "t", "v", and "s" attributes are of type number.
5.1. Simple Example
The following shows a temperature reading taken approximately "now"
by a 1-wire sensor device that was assigned the unique 1-wire address
of 0x000801EF221E:
{"m":[{ "n": "000801EF221E-Temp", "v":23.5 }]}
5.2. Complex Example
The following example show the voltage at Tue Jun 8 18:01:16 UTC 2010
along with the current at that time and at each second for the
previous 5 seconds. The device has a MAC address of 0017f202b5c4.
Jennings Expires April 27, 2011 [Page 6]
Internet-Draft Sensor Markup October 2010
{"m":[
{ "n": "voltage", "u": "V",
"v": 120.1, "anExtension": 0.0 },
{ "n": "current", "t": -5, "v": 1.2 },
{ "n": "current", "t": -4, "v": 1.30 },
{ "n": "current", "t": -3, "v": 0.14e1 },
{ "n": "current", "t": -2, "v": 1.5 },
{ "n": "current", "t": -1, "v": 1.6 },
{ "n": "current", "t": 0, "v": 1.7 }
],
"bn": "0017f202a5c4-",
"bt": 1276020076,
"someExtensions": "a value"
}
6. Usage Considerations
The measurements support sending both the current value of a sensor
as well as the an integrated sum. For many types of measurements,
the sum is more useful than the current value. For example, an
electrical meter that measures the energy a given computer uses will
typically want to measure the cumulative amount of energy used. This
is less prone to error than reporting the power each second and
trying to have something on the server side sum together all the
power measurements. If the network between the sensor and the meter
goes down over some period of time, when it comes back up, the
cumulative sum helps reflect what happened while the network was
down. A meter like this would typically report a measurement with
the units set to watts, but it would put the sum of energy used in
the "s" attribute of the measurement. It might optionally include
the current power in the "v" attribute.
While the benefit of using the integrated sum is fairly clear for
measurements like power and energy, it is less obvious for something
like temperature. Reporting the sum of the temperature makes it easy
to compute averages even when the individual temperature values are
not reported frequently enough to compute accurate averages.
Implementors are encouraged to report the cumulative sum as well as
the raw value of a given sensor.
Applications that use the cumulative sum values need to understand
they are very loosely defined by this specification, and depending on
the particular sensor implementation may behave in unexpected ways.
Applications should be able to deal with the following issues:
Jennings Expires April 27, 2011 [Page 7]
Internet-Draft Sensor Markup October 2010
1. Many sensors will allow the cumulative sums to "wrap" back to
zero after the value gets sufficiently large.
2. Some sensors will reset the cumulative sum back to zero when the
device is reset, loses power, or is replaced with a different
sensor.
3. Applications cannot make assumptions about when the device
started accumulating values into the sum.
Typically applications can make some assumptions about specific
sensors that will allow them to deal with these problems. A common
assumption is that for sensors whose measurement values are always
positive, the sum should never get smaller; so if the sum does get
smaller, the application will know that one of the situations listed
above has happened.
7. IANA Considerations
Note to RFC Editor: Please replace all occurrences of "RFC-AAAA"
with the RFC number of this specification.
7.1. Units Registry
IANA will create a registry of unit symbols. The primary purpose of
this registry is to make sure that symbols uniquely map to give type
of measurement. Definitions for many of these units can be found in
[NIST822] and [BIPM].
Jennings Expires April 27, 2011 [Page 8]
Internet-Draft Sensor Markup October 2010
+--------+----------------------------------------------+-----------+
| Symbol | Description | Reference |
+--------+----------------------------------------------+-----------+
| m | meter | RFC-AAAA |
| kg | kilogram | RFC-AAAA |
| s | second | RFC-AAAA |
| A | ampere | RFC-AAAA |
| K | kelvin | RFC-AAAA |
| cd | candela | RFC-AAAA |
| mol | mole | RFC-AAAA |
| Hz | hertz | RFC-AAAA |
| rad | radian | RFC-AAAA |
| sr | steradian | RFC-AAAA |
| N | newton | RFC-AAAA |
| Pa | pascal | RFC-AAAA |
| J | joule | RFC-AAAA |
| W | watt | RFC-AAAA |
| C | coulomb | RFC-AAAA |
| V | volt | RFC-AAAA |
| F | farad | RFC-AAAA |
| Ohm | ohm | RFC-AAAA |
| S | siemens | RFC-AAAA |
| Wb | weber | RFC-AAAA |
| T | tesla | RFC-AAAA |
| H | henry | RFC-AAAA |
| degC | degrees Celsius | RFC-AAAA |
| lm | lumen | RFC-AAAA |
| lx | lux | RFC-AAAA |
| Bq | becquerel | RFC-AAAA |
| Gy | gray | RFC-AAAA |
| Sv | sievert | RFC-AAAA |
| kat | katal | RFC-AAAA |
| pH | pH acidity | RFC-AAAA |
| % | Value of a switch. A value of 0.0 indicates | RFC-AAAA |
| | the switch is off while 100.0 indicates on. | |
| count | counter value | RFC-AAAA |
| %RH | Relative Humidity | RFC-AAAA |
| m2 | area | RFC-AAAA |
| l | volume in liters | RFC-AAAA |
| m/s | velocity | RFC-AAAA |
| m/s2 | acceleration | RFC-AAAA |
| l/s | flow rate in liters per second | RFC-AAAA |
| W/m2 | irradiance | RFC-AAAA |
| cd/m2 | luminance | RFC-AAAA |
| Bspl | bel sound pressure level | RFC-AAAA |
| bit/s | bits per second | RFC-AAAA |
Jennings Expires April 27, 2011 [Page 9]
Internet-Draft Sensor Markup October 2010
| lat | degrees latitude. Assumed to be in WGS84 | RFC-AAAA |
| | unless another reference frame is known for | |
| | the sensor. | |
| lon | degrees longitude. Assumed to be in WGS84 | RFC-AAAA |
| | unless another reference frame is known for | |
| | the sensor. | |
+--------+----------------------------------------------+-----------+
New entries can be added to the registration by either Expert Review
or IESG Approval as defined in [RFC5226]. Experts should exercise
their own good judgement but need to consider the following
guidelines:
1. There needs to be a real and compelling use for any new unit to
be added.
2. Units should define the semantic information and be chosen
carefully. Implementors need to remember that the same word may
be used in different real-life contexts. For example, degrees
when measuring latitude have no semantic relation to degrees
when measuring temperature; thus two different units are needed.
3. These measurements are produced by computers for consumption by
computers. The principle is that conversion has to be easily be
done when both reading and writing the media type. The value of
a single canonical representation outweighs the convenience of
easy human representations or loss of precision in a conversion.
4. Use of SI prefixes such as "k" before the unit is not allowed.
Instead one can represent the value using scientific notation
such a 1.2e3.
5. For a given type of measurement, there will only be one unit
type defined. So for length, meters are defined and other
lengths such as mile, foot, light year are not allowed. For
most cases, the SI unit is preferred.
6. Symbol names that could be easily confused with existing common
units or units combined with prefixes should be avoided. For
example, selecting a unit name of "mph" to indicate something
that had nothing to do with velocity would be a bad choice, as
"mph" is commonly used to mean miles per hour.
7. The following should not be used because the are common SI
prefixes: Y, Z, E, P, T, G, M, k, h, da, d, c, n, u, p, f, a,
z, y, Ki, Mi, Gi, Ti, Pi, Ei, Zi, Yi.
8. The following units should not be used as they are commonly used
to represent other measurements Ky, Gal, dyn, etg, P, St, Mx, G,
Oe, Gb, sb, Lmb, ph, Ci, R, RAD, REM, gal, bbl, qt, degF, Cal,
BTU, HP, pH, B/s, psi, Torr, atm, at, bar, kWh.
9. The unit names are case sensitive and the correct case needs to
be used, but symbols that differ only in case should not be
allocated.
Jennings Expires April 27, 2011 [Page 10]
Internet-Draft Sensor Markup October 2010
10. A number after a unit typically indicates the previous unit
raised to that power, and the / indicates that the units that
follow are the reciprocal. A unit should have only one / in the
name.
7.2. Media Type Registration
The following registrations are done following the procedure
specified in [RFC4288] and [RFC3023].
Note to RFC Editor: Please replace all occurrences of "RFC-AAAA"
with the RFC number of this specification.
7.2.1. senml+json Media Type Registration
To: ietf-types@iana.org
Subject: Registration of media type application/senml+json
Type name: application
Subtype name: senml+json
Required parameters: none
Optional parameters: none
Encoding considerations: Must be encoded as using a subset of the
encoding allowed in [RFC4627]. Specifically, only the ASCII[RFC0020]
subset of the UTF-8 characters are allowed. This simplifies
implementation of very simple system and does not impose any
significant limitations as all this data is meant for machine to
machine communications and is not meant to be human readable.
Security considerations: Sensor data can contain a wide range of
information ranging from information that is very public, such the
outside temperature in a given city, to very private information that
requires integrity and confidentiality protection, such as patient
health information. This format does not provide any security and
instead relies on the transport protocol that carries it to provide
security. Given applications need to look at the overall context of
how this media type will be used to decide if the security is
adequate.
Interoperability considerations: Applications should ignore any JSON
key value pairs that they do not understand. This allows backwards
compatibility extensions to this specification. The "ver" field can
be used to ensure the receiver supports a minimal level of
Jennings Expires April 27, 2011 [Page 11]
Internet-Draft Sensor Markup October 2010
functionality needed by the creator of the JSON object.
Published specification: RFC-AAAA
Applications that use this media type: The type is used by systems
that report electrical power usage and environmental information such
as temperature and humidity. It can be used for a wide range of
sensor reporting systems.
Additional information:
Magic number(s): none
File extension(s): senml
Macintosh file type code(s): none
Person & email address to contact for further information: Cullen
Jennings <c.jennings@ieee.org>
Intended usage: COMMON
Restrictions on usage: None
Author: Cullen Jennings <c.jennings@ieee.org>
Change controller: IESG
8. Security Considerations
Sensor data can range from information with almost no security
considerations, such as the current temperature in a given city, to
highly sensitive medical or location data. This specification
provides no security protection for the data but is meant to be used
inside another container or transport protocol such as S/MIME or HTTP
with TLS that can provide integrity, confidentiality, and
authentication information about the source of the data.
Further discussion of security proprieties can be found in
Section 7.2.
9. Acknowledgement
I would like to thank Lisa Dusseault, Joe Hildebrand, Lyndsay
Campbell, Martin Thomson, Bjoern Hoehrmann, and Carsten Bormann for
their review comments.
Jennings Expires April 27, 2011 [Page 12]
Internet-Draft Sensor Markup October 2010
10. References
10.1. Normative References
[RFC4627] Crockford, D., "The application/json Media Type for
JavaScript Object Notation (JSON)", RFC 4627, July 2006.
[RFC3023] Murata, M., St. Laurent, S., and D. Kohn, "XML Media
Types", RFC 3023, January 2001.
[RFC4288] Freed, N. and J. Klensin, "Media Type Specifications and
Registration Procedures", BCP 13, RFC 4288, December 2005.
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119, March 1997.
[IEEE.754.1985]
Institute of Electrical and Electronics Engineers,
"Standard for Binary Floating-Point Arithmetic",
IEEE Standard 754, August 1985.
[RFC5226] Narten, T. and H. Alvestrand, "Guidelines for Writing an
IANA Considerations Section in RFCs", BCP 26, RFC 5226,
May 2008.
10.2. Informative References
[I-D.ietf-core-coap]
Shelby, Z., Frank, B., and D. Sturek, "Constrained
Application Protocol (CoAP)", draft-ietf-core-coap-02
(work in progress), September 2010.
[BIPM] Bureau International des Poids et Mesures, "The
International System of Units (SI)", 8th edition, 2006 .
[NIST822] Thompson, A. and B. Taylor, "Guide for the Use of the
International System of Units (SI)", NIST Special
Publication 811, 2008 Edition .
[RFC5952] Kawamura, S. and M. Kawashima, "A Recommendation for IPv6
Address Text Representation", RFC 5952, August 2010.
[RFC4122] Leach, P., Mealling, M., and R. Salz, "A Universally
Unique IDentifier (UUID) URN Namespace", RFC 4122,
July 2005.
[RFC0020] Cerf, V., "ASCII format for network interchange", RFC 20,
October 1969.
Jennings Expires April 27, 2011 [Page 13]
Internet-Draft Sensor Markup October 2010
Author's Address
Cullen Jennings
Cisco
170 West Tasman Drive
San Jose, CA 95134
USA
Phone: +1 408 421-9990
Email: fluffy@cisco.com