Skip to main content

MICA-NEX v0.3: Authenticated Measurement Ingestion for Model-Agnostic Nano-Instrument Agent Swarms
draft-watts-mica-nex-measurement-ingestion-00

Document Type Active Internet-Draft (individual)
Author Deonté Watts
Last updated 2026-10-22
RFC stream (None)
Intended RFC status (None)
Formats
Stream Stream state (No stream defined)
Consensus boilerplate Unknown
RFC Editor Note (None)
IESG IESG state I-D Exists
Telechat date (None)
Responsible AD (None)
Send notices to (None)
draft-watts-mica-nex-measurement-ingestion-00
Network Working Group                                        D. O. Watts
Internet-Draft                                       GoodShyt Group Inc.
Intended status: Informational                           22 October 2026
Expires: 25 April 2027

 MICA-NEX v0.3: Authenticated Measurement Ingestion for Model-Agnostic
                      Nano-Instrument Agent Swarms
             draft-watts-mica-nex-measurement-ingestion-00

Abstract

   This document describes a narrow, testable next step in the MICA-NEX
   proposal: cryptographically binding nanoscale instrument measurement
   claims to externally provisioned acquisition and calibration signer
   roles while denying model planners the ability to self-certify
   measurement status.  The reference implementation uses Ed25519
   signatures, SHA-256 content binding, typed units, time windows,
   source-kind separation, and a persistent local replay ledger.  In a
   hardware-disconnected test harness, 60/60 signed synthetic test
   records from three simulated instrument classes were admitted and
   30/30 adversarial cases were rejected for the expected reason; 28/28
   Python tests passed.  No instrument, laboratory calibration, external
   reviewer, clinical context or independent physical replication was
   involved.  Signature validity is deliberately distinguished from
   scientific validity.

Status of This Memo

   This Internet-Draft is submitted in full conformance with the
   provisions of BCP 78 and BCP 79.

   Internet-Drafts are working documents of the Internet Engineering
   Task Force (IETF).  Note that other groups may also distribute
   working documents as Internet-Drafts.  The list of current Internet-
   Drafts is at https://datatracker.ietf.org/drafts/current/.

   Internet-Drafts are draft documents valid for a maximum of six months
   and may be updated, replaced, or obsoleted by other documents at any
   time.  It is inappropriate to use Internet-Drafts as reference
   material or to cite them other than as "work in progress."

   This Internet-Draft will expire on 25 April 2027.

Copyright Notice

   Copyright (c) 2026 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

Watts                     Expires 25 April 2027                 [Page 1]
Internet-Draft       MICA-NEX Measurement Ingestion         October 2026

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents (https://trustee.ietf.org/
   license-info) in effect on the date of publication of this document.
   Please review these documents carefully, as they describe your rights
   and restrictions with respect to this document.  Code Components
   extracted from this document must include Revised BSD License text as
   described in Section 4.e of the Trust Legal Provisions and are
   provided without warranty as described in the Revised BSD License.

Table of Contents

   1.  Introduction and Research Question  . . . . . . . . . . . . .   2
   2.  Architecture and Principle  . . . . . . . . . . . . . . . . .   3
   3.  Cryptographic and Epistemic Checks  . . . . . . . . . . . . .   3
   4.  Experiment EXP-02: Reproducible Synthetic Gate  . . . . . . .   4
   5.  Falsifiability, Limitations, and Priority . . . . . . . . . .   5
   6.  Next Mandatory Gate . . . . . . . . . . . . . . . . . . . . .   5
   7.  Provenance and Disclosure . . . . . . . . . . . . . . . . . .   5
   8.  IANA Considerations . . . . . . . . . . . . . . . . . . . . .   6
   9.  Security Considerations . . . . . . . . . . . . . . . . . . .   6
   10. Informative References  . . . . . . . . . . . . . . . . . . .   6
   Author's Address  . . . . . . . . . . . . . . . . . . . . . . . .   7

1.  Introduction and Research Question

   The prior MICA-NEX v0.1 gate [MICANEX01] accepts only SIMULATED
   records, so it cannot truthfully ingest MEASURED claims without a new
   interface.  This conflict was logged as EM-005 in EXP-01 v0.2.  Our
   question is whether one strictly typed, model-neutral acquisition-
   ingestion contract can accept records across scanning-probe,
   microfluidic-fluorescence and electrochemical categories while
   rejecting spoofed measurement authority and preserving evidence
   classification.

   Do not confuse a signature authenticating a claim with a verified
   physical measurement or traceable calibration.  NIST defines
   metrological traceability via a documented calibration chain
   contributing to uncertainty [NIST-TRACEABILITY].  This implementation
   checks a declaration and its file digest, not the validity of any
   real-world calibration chain.

   This Internet-Draft is a faithful conversion of the author's research
   report "MICA-NEX v0.3: Authenticated Measurement Ingestion for Model-
   Agnostic Nano-Instrument Agent Swarms -- A hardware-disconnected,
   falsifiable software research experiment", Version 0.3, dated 20
   October 2026.  Mathematical notation and the table have been rendered
   in plain text.  It is published for discussion; it is not a standard.

Watts                     Expires 25 April 2027                 [Page 2]
Internet-Draft       MICA-NEX Measurement Ingestion         October 2026

2.  Architecture and Principle

   The agent coordinator issues an unprivileged read-only request;
   separate laboratory holders would sign acquisition and calibration
   data outside the agent runtime.  The central verifier binds the
   signed claim to bytes and prescribed instrument semantics.

     Untrusted planner -> deterministic policy
       -> independent operator-record source
       -> signed/typed ingestion -> evidence receipt
       -> independent scientific review

     No actuation path in this prototype; no AI-owned signing keys.

   Three unit profiles are fixed: scanning-probe length in nm,
   microfluidic concentration in nM, and electrochemical potential in V.
   These units are illustrative for the narrow test, not a universal
   dimensional ontology.

3.  Cryptographic and Epistemic Checks

   Let R be raw acquisition bytes, C be the calibration document, A the
   signed acquisition claim, and K_A, K_C separately provisioned public
   keys.  Admission requires:

     Verify_{K_A}(A, sigma_A)               = 1
     Verify_{K_C}(C_claim, sigma_C)         = 1
     SHA256(R)                              = A.raw_sha256
     SHA256(C)                              = C_claim.evidence_sha256
     unit(A) = unit(C_claim)                = U_i
     t_cal,start  <=  t_A  <=  t_cal,end

   Ed25519 is specified by RFC 8032 [RFC8032].  The software uses
   project-specific sorted-key JSON with restrictive value types,
   labeled MICA-NEX-CJ/1.  It does not claim RFC 8785 compliance
   [RFC8785]; cross-language canonicalization is deferred.  Duplicate
   input JSON member keys are refused.

   The post-signature state is one of:

   *  TEST_FIXTURE + TEST_RECORD =>
      TEST_RECORD_AUTHENTICATED_NOT_PHYSICAL;

   *  INSTRUMENT_CAPTURE + MEASURED_CLAIM =>
      AUTHENTICATED_CLAIM_PHYSICAL_VALIDATION_PENDING;

   *  all other source/evidence combinations are rejected.

Watts                     Expires 25 April 2027                 [Page 3]
Internet-Draft       MICA-NEX Measurement Ingestion         October 2026

   Neither positive case can establish independent physical validation.
   The distinction resembles the separation between provenance
   activities, agents, and entities in the W3C PROV model [W3C-PROV],
   without claiming implementation of PROV-O.

4.  Experiment EXP-02: Reproducible Synthetic Gate

   Ephemeral Ed25519 keys are created by a test harness in memory and
   never packaged as laboratory credentials.  A deterministic trial
   runner constructs 20 synthetic acquisition records per substrate plus
   ten negative-control cases per substrate.  It calls a model-neutral
   policy coordinator and a common ingestion verifier.  The test harness
   does not access an actual microscope, optical sensor or potentiostat.
   Units, hashes, state transitions, and SQLite replay protection are
   exercised on synthetic bytes only.

         +=====================+========+=======+================+
         | Test class          | Passed | Total | Interpretation |
         +=====================+========+=======+================+
         | Signed TEST_FIXTURE | 60     | 60    | Software mock  |
         | records admitted    |        |       | only           |
         +---------------------+--------+-------+----------------+
         | Adversarial cases   | 30     | 30    | Synthetic      |
         | correctly rejected  |        |       | negatives      |
         +---------------------+--------+-------+----------------+
         | Local unit tests    | 28     | 28    | Python         |
         |                     |        |       | unittest       |
         +---------------------+--------+-------+----------------+
         | Physical equipment  | 0      | 0     | NOT RUN        |
         | connections         |        |       |                |
         +---------------------+--------+-------+----------------+
         | Independent third-  | 0      | 0     | NOT RUN        |
         | party reproductions |        |       |                |
         +---------------------+--------+-------+----------------+

                          Table 1: EXP-02 results

   Negative scenarios include an agent-held forged key, false evidence-
   state promotion, changed raw or calibration bytes, expired
   calibration, inappropriate unit, stale record, forbidden physical
   effect, replay, and undeclared fields.  All accepted records were
   labeled as test fixtures; no physical observation was synthesized
   into a scientifically verified one.

Watts                     Expires 25 April 2027                 [Page 4]
Internet-Draft       MICA-NEX Measurement Ingestion         October 2026

5.  Falsifiability, Limitations, and Priority

   Software falsifier: Show any unauthorized or altered record accepted
   by exactly this frozen gate and verified test conditions, or a test
   fixture classified as physically validated.  Physical falsifier: When
   actually acquiring from three distinct calibrated instruments, show
   an irreducible schema/semantics change or a safety boundary failure
   needed for one class.  These are prospective experiments, not
   completed results.

   The current code does not isolate a verifier OS process or protect a
   SQLite ledger from a privileged actor, provide HSM-backed keys or
   revocation, audit calibration traceability, verify vendor instrument
   identity, or enforce independent hardware interlocks.  It does not
   establish that its components are novel compared with existing
   middleware, digital signatures, or provenance standards.  There is no
   clinical or nano-robotic test and no evidence of energy improvement.
   Signed external review remains NOT RUN; the separate reviewer-
   signature checker cannot establish social or procedural reviewer
   independence.

6.  Next Mandatory Gate

   Freeze the v0.3 contract, obtain a separately authorized laboratory
   and reviewer, pre-register independently produced expected results,
   then collect signed records from genuinely calibrated, independently
   operated scanning-probe, fluorescence and electrochemical measurement
   instruments.  Preserve original raw bytes, calibration chain,
   reviewer-controlled key metadata, environment and signed replication
   report.  Test real-world precision, uncertainty, source
   authentication, and instrument-operation safety independently of the
   software gate.

   Status: SOFTWARE SYNTHETIC PASS; PHYSICAL INTEROPERABILITY NOT RUN;
   INDEPENDENT REPLICATION NOT RUN; FIRST-IN-WORLD NOVELTY NOT
   ESTABLISHED.

7.  Provenance and Disclosure

   Project PI and attribution: Deonte O'dell Watts, ORCID
   0009-0005-8586-3650, GoodShyt Group Inc. AI-assisted design,
   implementation, literature checking and drafting; test authorship is
   not independent.  Attribution here is not a legal declaration of
   inventorship or patent priority.  Project concept first documented
   October 19, 2026.

Watts                     Expires 25 April 2027                 [Page 5]
Internet-Draft       MICA-NEX Measurement Ingestion         October 2026

8.  IANA Considerations

   This document has no IANA actions.

9.  Security Considerations

   A valid signature proves only control of a signing key and integrity
   of the signed bytes under the stated trust assumptions; it does not
   prove that a measurement is correct, calibrated, traceable or
   physically valid.  Implementations derived from this design need to
   keep signing keys out of reach of planning agents and of any process
   that can alter the trust store, the replay ledger or the trusted
   clock, because any of these would let an agent self-certify
   measurement status.  The prototype's replay ledger is a local SQLite
   file that a privileged actor can modify; it offers no HSM-backed key
   custody and no key revocation.  The project-specific canonical JSON
   (MICA-NEX-CJ/1) is not RFC 8785; cross-implementation
   canonicalization differences can cause verification failures or, if
   handled loosely, signature confusion, which is why duplicate JSON
   member names are rejected.  The prototype has no actuation path; any
   future connection to physical instruments requires independent
   hardware interlocks and safety review outside the software gate.

10.  Informative References

   [RFC8032]  Josefsson, S. and I. Liusvaara, "Edwards-Curve Digital
              Signature Algorithm (EdDSA)", RFC 8032,
              DOI 10.17487/RFC8032, January 2017,
              <https://www.rfc-editor.org/info/rfc8032>.

   [RFC8785]  Rundgren, A., Jordan, B., and S. Erdtman, "JSON
              Canonicalization Scheme (JCS)", RFC 8785,
              DOI 10.17487/RFC8785, June 2020,
              <https://www.rfc-editor.org/info/rfc8785>.

   [NIST-TRACEABILITY]
              National Institute of Standards and Technology, "NIST
              Policy on Metrological Traceability", Undated policy page
              consulted 2026-10-20,
              <https://www.nist.gov/calibrations/traceability>.

   [W3C-PROV] W3C Provenance Working Group, "PROV Model Primer", 2013,
              <https://www.w3.org/TR/prov-primer/>.

Watts                     Expires 25 April 2027                 [Page 6]
Internet-Draft       MICA-NEX Measurement Ingestion         October 2026

   [MICANEX01]
              Watts, D. O., "MICA-NEX v0.1: A Substrate-Agnostic,
              Physically Governed Interface for Agentic Nanotechnology
              Research", DOI 10.5281/zenodo.23488201, 2026,
              <https://doi.org/10.5281/zenodo.23488201>.

Author's Address

   Deonté O'dell Watts
   GoodShyt Group Inc.
   Email: deonte@goodshyt.fun
   URI:   https://orcid.org/0009-0005-8586-3650

Watts                     Expires 25 April 2027                 [Page 7]