INTERNET-DRAFT                                              Mingui Zhang
Intended Status: Standards Track                           Lianshu Zheng
                                                              Feng Zheng
                                                                  Huawei
                                                                 Fu Qiao
                                                            China Mobile
Expires: June 5, 2016                                   December 3, 2015

                   YANG Data Model for NVO3 Protocols
                    draft-zhang-nvo3-yang-cfg-02.txt

Abstract

   This document describes the base YANG data model that can be used by
   operators to configure and manage NVO3 protocols.

Status of this Memo

   This Internet-Draft is submitted to IETF in full conformance with the
   provisions of BCP 78 and BCP 79.

   Internet-Drafts are working documents of the Internet Engineering
   Task Force (IETF), its areas, and its working groups.  Note that
   other groups may also distribute working documents as
   Internet-Drafts.

   Internet-Drafts are draft documents valid for a maximum of six months
   and may be updated, replaced, or obsoleted by other documents at any
   time.  It is inappropriate to use Internet-Drafts as reference
   material or to cite them other than as "work in progress."

   The list of current Internet-Drafts can be accessed at
   http://www.ietf.org/1id-abstracts.html

   The list of Internet-Draft Shadow Directories can be accessed at
   http://www.ietf.org/shadow.html

Copyright and License Notice

   Copyright (c) 2015 IETF Trust and the persons identified as the
   document authors. All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (http://trustee.ietf.org/license-info) in effect on the date of
   publication of this document. Please review these documents
   carefully, as they describe your rights and restrictions with respect
 

Mingui Zhang, et al       Expires June 5, 2016                  [Page 1]
INTERNET-DRAFT     YANG Data Model for NVO3 Protocols   December 3, 2015

   to this document. Code Components extracted from this document must
   include Simplified BSD License text as described in Section 4.e of
   the Trust Legal Provisions and are provided without warranty as
   described in the Simplified BSD License.

Table of Contents

   1. Introduction  . . . . . . . . . . . . . . . . . . . . . . . . .  3
   2. Acronyms and Terminology  . . . . . . . . . . . . . . . . . . .  3
     2.1. Acronyms  . . . . . . . . . . . . . . . . . . . . . . . . .  3
     2.2. Terminology . . . . . . . . . . . . . . . . . . . . . . . .  3
   3. The YANG Data Model for NVO3  . . . . . . . . . . . . . . . . .  3
     3.1. The Configuration Parameters  . . . . . . . . . . . . . . .  3
       3.1.1. NVE ID  . . . . . . . . . . . . . . . . . . . . . . . .  4
       3.1.2. Encapsulation Type  . . . . . . . . . . . . . . . . . .  4
       3.1.3. Source and Destination UDP Port . . . . . . . . . . . .  4
       3.1.4. Virtual Network Instance  . . . . . . . . . . . . . . .  4
       3.1.5. Flags in the Header . . . . . . . . . . . . . . . . . .  4
       3.1.6. BUM Mode  . . . . . . . . . . . . . . . . . . . . . . .  5
     3.2. Statistics  . . . . . . . . . . . . . . . . . . . . . . . .  5
     3.3. Model Structure . . . . . . . . . . . . . . . . . . . . . .  5
     3.4. YANG Module . . . . . . . . . . . . . . . . . . . . . . . .  6
   4. Security Considerations . . . . . . . . . . . . . . . . . . . . 13
   5. IANA Considerations . . . . . . . . . . . . . . . . . . . . . . 13
   Acknowledgements . . . . . . . . . . . . . . . . . . . . . . . . . 13
   6. References  . . . . . . . . . . . . . . . . . . . . . . . . . . 13
     6.1. Normative References  . . . . . . . . . . . . . . . . . . . 13
     6.2. Informative References  . . . . . . . . . . . . . . . . . . 14
   Author's Addresses . . . . . . . . . . . . . . . . . . . . . . . . 15

 

Mingui Zhang, et al       Expires June 5, 2016                  [Page 2]
INTERNET-DRAFT     YANG Data Model for NVO3 Protocols   December 3, 2015

1. Introduction

   Network Virtualization Overlays (NVO3) enable network virtualization
   for data center networks environment that assumes an IP-based
   underlay.

   YANG [RFC6020] is a data definition language that was introduced to
   define the contents of a conceptual data store that allows networked
   devices to be managed using NETCONF [RFC6241]. This document
   specifies a YANG data model that can be used to configure and manage
   NVO3 protocols. The model covers the configuration of preliminary
   NVO3 instances as well as their operation states. We call it the base
   model for NVO3 in this document.

   Two default data plane encapsulation techniques for NVO3 are
   incorporated in the base module. It allows other possible
   encapsulations developed in the industry later on to be included by
   introducing a new encapsulation as a new 'choice'. As new solutions
   for NVO3 are developed, corresponding YANG data modules may be
   specified. The base module can be augmented to accommodate these new
   solutions.

2. Acronyms and Terminology

2.1. Acronyms

   NVO3: Network Virtualization Overlays
   VNI: Virtual Network Instance
   BUM: Broadcast, Unknown Unicast, Multicast traffic

2.2. Terminology

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
   document are to be interpreted as described in RFC 2119 [RFC2119].

   Familiarity with [RFC7364], [RFC7365], [I-D.ietf-nvo3-dataplane-
   requirements] and [RFC7348] is assumed in this document.

3. The YANG Data Model for NVO3

   The NVO3 base YANG module is divided in three containers. The first
   container contains writable parameters. The second container contains
   the writable enablers per VNI for the statistical operational states
   as well as the status of these enablers. The third container contains
   the statistical operational states. 

3.1. The Configuration Parameters
 

Mingui Zhang, et al       Expires June 5, 2016                  [Page 3]
INTERNET-DRAFT     YANG Data Model for NVO3 Protocols   December 3, 2015

3.1.1. NVE ID

   The 'nvo3Nves' list contains NVEs under the management. The NVE is
   identified using the 'srcAddr', which is the underlay IP address of
   the NVE. 

3.1.2. Encapsulation Type

   The encapsulation type of NVO3 is to be determined by the operators
   according to their network. NVO3 encapsulation arising from the
   industry is not unique. The value of 'encapType' determines the
   encapsulation. Besides the default VxLAN encapsulation [RFC7348], the
   module also allows other possible encapsulation, for example the
   NVGRE encapsulation [I-D.sridharan-virtualization-nvgre]. It can be
   extended to include more encapsulation choices.

3.1.3. Source and Destination UDP Port

   If the encapsulation type is VxLAN, it's recommended the source UDP
   port is calculated using a hash of fields (e.g., source IP address,
   destination IP address, protocol type, source MAC address and
   destination MAC address) from the inner packet. The bit value of
   'srcUdpPortGenRuleFlags' indicates whether each field is used in the
   hashing function with the high-order bit indicating the first hashing
   field.  

   The value of destination UDP port is set to be 'destUdpPort'. For
   VxLAN, IANA has assigned the value 4789 for the UDP destination port,
   and this value SHOULD be used by default as the destination UDP port
   [RFC7348].

3.1.4. Virtual Network Instance

   A Virtual Network Instance ('VNI') is a specific VN instance on an
   NVE [RFC7365]. At each NVE, a Tenant System is connect to VNIs
   through Virtual Access Points (VAP). VAPs can be physical ports or
   virtual ports identified by the bridge domain Identifier ('bdId').
   The mapping between VNI and bdId is managed by the operator.

3.1.5. Flags in the Header

   Flags in the NVO3 header are to be configured. For VxLAN, the I bit
   of 'flag' MUST be set to 1 while other 7 bits are reserved and MUST
   be set to zero on transmission and ignored on receipt. For NVGRE,
   bits in position 0 and 3 MUST be set to zero. The bit in position 2
   MUST be set to 1. Bits from position 4 through 12 are reserved and
   MUST be set to zero on transmission and ignored on receipt.

 

Mingui Zhang, et al       Expires June 5, 2016                  [Page 4]
INTERNET-DRAFT     YANG Data Model for NVO3 Protocols   December 3, 2015

3.1.6. BUM Mode

   An NVE SHOULD support either ingress replication or point to
   multipoint tunnels [I-D.ietf-nvo3-dataplane-requirements] on a per-
   VNI basis. It is possible that both modes be used simultaneously in
   one NVO3 network by different NVEs. 

   If ingress replication is used, the receiver addresses are listed in
   'peerAddr'. If the choice is point to multipoint tunnels, the
   multicast address is given as 'multiAddr'. 

3.2. Statistics

   Operators can determine whether a NVE should gather statistic values
   on a per-VNI base. The enablers are contained in the 'nvo3Info' list
   as 'statisticsEnable' leaf. 

   If the gathering for a VNI is enabled, the statistical information
   about the local NVEs, the remote NVEs, the flows and the MAC
   addresses will be collected by the NVEs in this VNI. 

3.3. Model Structure

   module: nvo3-base
      +--rw nvo3Nves
      |  +--rw nvo3Nve* [ifName]
      |     +--rw ifName               string
      |     +--rw srcAddr?             inet:ip-address
      |     +--rw (encapType)?
      |     |  +--:(vxlan)
      |     |     +--rw srcUdpPortGenRule?   uint8
      |     |     +--rw destUdpPort?         uint16
      |     +--rw members
      |        +--rw member* [VNI]
      |           +--rw VNI          uint32
      |           +--rw bdId         uint32
      |           +--rw (encapType)?
      |           |  +--:(vxlan)
      |           |  |  +--rw vxlanFlag?   flags-vxlan
      |           |  +--:(nvgre)
      |           |     +--rw nvgreFlag?   flags-nvgre
      |           |     +--rw flowId?      uint8
      |           +--rw (bumMode)?
      |              +--:(headEnd)
      |              |  +--rw peerAddr*    inet:ip-address
      |              +--:(multiGroup)
      |                 +--rw multiAddr?   inet:ip-address
      +--rw nvo3Infos
 

Mingui Zhang, et al       Expires June 5, 2016                  [Page 5]
INTERNET-DRAFT     YANG Data Model for NVO3 Protocols   December 3, 2015

      |  +--rw nvo3Info* [VNI]
      |     +--rw VNI                 uint32
      |     +--rw statisticsEnable?   enumeration
      |     +--ro status?             enumeration
      +--rw nvo3Statistics
         +--ro localNVE*
         |  +--ro count?    uint64
         |  +--ro ipAddr*   inet:ip-address
         +--ro remoteNVE*
         |  +--ro count?    uint64
         |  +--ro ipAddr*   inet:ip-address
         +--rw flowStatistics
         |  +--ro instanceCount?   uint64
         |  +--ro flowStatistic*
         |     +--ro VNI?                       uint32
         |     +--ro inPacketsCount?            uint64
         |     +--ro inBytesCount?              uint64
         |     +--ro inUnicasts?                uint64
         |     +--ro inMulticasts?              uint64
         |     +--ro inBroadcasts?              uint64
         |     +--ro inUnknownUnicastDrops?     uint64
         |     +--ro inUnknownMulticastDrops?   uint64
         |     +--ro inBroadcastsDrops?         uint64
         |     +--ro outPacketsCount?           uint64
         |     +--ro outBytesCount?             uint64
         |     +--ro outUnicasts?               uint64
         |     +--ro outMulticasts?             uint64
         |     +--ro outBroadcasts?             uint64
         +--rw MacStatistics
            +--ro MacStatistic*
               +--ro VNI?          uint32
               +--ro vmMacCount?   uint64

  Figure 3.1. The tree structure of YANG module for NVO3 configuration

3.4. YANG Module

   <CODE BEGINS>
   module nvo3-base {
     namespace "http://www.huawei.com/netconf/nvo3";
     //namespace need to be assigned by IANA
     prefix "nvo3";
     import ietf-inet-types {
       prefix "inet";
     }
     organization "IETF NVO3 Working Group";
     contact "vero.zheng@huawei.com
       zhangmingui@huawei.com
 

Mingui Zhang, et al       Expires June 5, 2016                  [Page 6]
INTERNET-DRAFT     YANG Data Model for NVO3 Protocols   December 3, 2015

       habby.zheng@huawei.com";
     description "nvo3 yang module";
     revision "2014-10-21";

     typedef flags-vxlan {
       type bits {
         bit validVni {
           position 4;
         }
       }
     }

     typedef  flags-nvgre {
       type bits {
         bit zero{
           position 0;
         }
         bit KeyPresent{
           position 2;
         }
         bit three{
           position 3;
         }
       }      
     }

     container nvo3Nves {
       list nvo3Nve {
         key "ifName";
         leaf ifName {
           description
             "Interface name.";
           type string;
           mandatory "true";
         }
         leaf srcAddr {
           description
             "Local NVE address.";      
           type inet:ip-address;
         }
         choice encapType{
           case vxlan{
             leaf srcUdpPortGenRule {
               description
                 "The rule of generating source udp port.";
               type uint8;
             }
             leaf destUdpPort {
 

Mingui Zhang, et al       Expires June 5, 2016                  [Page 7]
INTERNET-DRAFT     YANG Data Model for NVO3 Protocols   December 3, 2015

               description
                 "Destination udp port.";
               default "4789";
               type uint16{
                 range "0 .. 65535";
               }
             }
           }
         }
         container members {
           list member {
             key "VNI";
             leaf VNI {
               description 
                 "Virutal Network Instance (VNI). For VxLAN, it is 
                 VXLAN Network Identifier; For NVGRE, it is Virtual 
                 Subnet Identifier.";
               mandatory "true";
               type uint32 {
                 range "1 .. 16777215";
               }
             }
             leaf bdId {
               description
                 "Bridge Domain ID";
               mandatory "true";
               type uint32 {
                 range "1 .. 32768";
               }
             }
             choice encapType{
               case vxlan{
                 leaf vxlanFlag {
                   description
                     "The 8 bits flags of VXLAN. The I flag MUST be 
                     set to 1 for a valid VNI. Others are reserved.";
                   type flags-vxlan;
                 }
               }
               case nvgre{
                 leaf nvgreFlag {
                     description
                       "The 13 bits flags of NVGRE. Bit 0 and 3 are set 
                       to 0 while bit 2 is set to 1. 
                       Others are reserved";
                     type flags-nvgre;
                 }
                 leaf flowId {
 

Mingui Zhang, et al       Expires June 5, 2016                  [Page 8]
INTERNET-DRAFT     YANG Data Model for NVO3 Protocols   December 3, 2015

                   description
                     "This is an 8-bit value that is used to provide 
                     per-flow entropy for flows in the same VSID. 
                     If a FlowID is not generated, it MUST be set to 
                     all zero.";
                   type uint8;
                 }
               }
             }
             choice bumMode{
               case headEnd{
                 leaf-list peerAddr {
                   description
                     "Remote NVE address.";
                   type inet:ip-address;
                 }
               }
               case multiGroup{
                 leaf multiAddr {
                   description
                     "The multicast group address.";
                   type inet:ip-address;
                 }
               }
             }

           }
         }//container members
       }
     }//container nvo3Nves

     container nvo3Infos {
       list nvo3Info {
         key "VNI";
         leaf VNI {
           description
             "Virutal Network Instance (VNI). For VxLAN, it is 
             VXLAN Network Identifier; For NVGRE, it is Virtual 
             Subnet Identifier.";
           mandatory "true";
           type uint32 {
           range "1 .. 16777215";
           }
         }
         leaf statisticsEnable {
           type enumeration {
             enum enable {
               value "0";
 

Mingui Zhang, et al       Expires June 5, 2016                  [Page 9]
INTERNET-DRAFT     YANG Data Model for NVO3 Protocols   December 3, 2015

               description
                 "Enable";
             }
             enum disable {
               value "1";
               description
                 "Disable";
             }
           }
         }
         leaf status {
           config "false";
           type enumeration {
             enum up {
               value "0";
               description
                 "Up";
             }
             enum down {
               value "1";
               description
                 "Down";
             }
           }
         }      
       }
     }//container nvo3Infos

     container nvo3Statistics {
       list localNVE {
         config "false";
         leaf count {
           description
             "The value of count.";
           config "false";
           type uint64;
         }  
         leaf-list ipAddr {
           description
             "List of local NVE address.";
           config "false";
           type inet:ip-address;
         }
       }  
       list remoteNVE {
         config "false";
         leaf count {
           description
 

Mingui Zhang, et al       Expires June 5, 2016                 [Page 10]
INTERNET-DRAFT     YANG Data Model for NVO3 Protocols   December 3, 2015

             "The value of count.";
           config "false";
           type uint64;
         }  
         leaf-list ipAddr {
           description
             "List of remote NVE address.";
           config "false";
           type inet:ip-address;
         }
       }  
       container flowStatistics {
         grouping inputStatistics {
           leaf inPacketsCount {
             config "false";
             type uint64;
           }  
           leaf inBytesCount {
             config "false";
             type uint64;
           }  
           leaf inUnicasts {
             config "false";
             type uint64;
           }  
           leaf inMulticasts {
             config "false";
             type uint64;
           }  
           leaf inBroadcasts {
             config "false";
             type uint64;
           }  
           leaf inUnknownUnicastDrops {
             config "false";
             type uint64;
           }
           leaf inUnknownMulticastDrops {
             config "false";
             type uint64;
           }  
           leaf inBroadcastsDrops {
             config "false";
             type uint64;
           }
         }
         grouping outputStatistics {
           leaf outPacketsCount {
 

Mingui Zhang, et al       Expires June 5, 2016                 [Page 11]
INTERNET-DRAFT     YANG Data Model for NVO3 Protocols   December 3, 2015

             config "false";
             type uint64;
           }  
           leaf outBytesCount {
             config "false";
             type uint64;
           }  
           leaf outUnicasts {
             config "false";
             type uint64;
           }  
           leaf outMulticasts {
             config "false";
             type uint64;
           }  
           leaf outBroadcasts {
             config "false";
             type uint64;
           }  
         }
         leaf instanceCount {
           config "false";
           type uint64;
         }  
         list flowStatistic{
           config "false";
           leaf VNI {
             description
               "Virutal Network Instance (VNI). For VxLAN, it is 
               VXLAN Network Identifier; For NVGRE, it is Virtual 
               Subnet Identifier.";
             config "false";
             type uint32;
           }
           uses inputStatistics;
           uses outputStatistics;
         }
       }//container flowStatistics
       container MacStatistics {
         list MacStatistic{
           config "false";
           leaf VNI {
             description
               "Virutal Network Instance (VNI). For VxLAN, it is 
               VXLAN Network Identifier; For NVGRE, it is Virtual 
               Subnet Identifier.";
             config "false";
             type uint32;
 

Mingui Zhang, et al       Expires June 5, 2016                 [Page 12]
INTERNET-DRAFT     YANG Data Model for NVO3 Protocols   December 3, 2015

           }
           leaf vmMacCount {
             description
               "Count of learning Mac addresses for the VNI.";
             config "false";
             type uint64;
           }
         }
       }//container MacStatistics
     }//container nvo3Statistics
   }
   <CODE ENDS>

4. Security Considerations

   This document raises no new security issues.

5. IANA Considerations

   The namespace URI defined in Section 3.3 need be registered in the
   IETF XML registry [RFC3688]. 

   This document need to register the 'nvo3-base' YANG module in the
   YANG Module Names registry [RFC6020].

Acknowledgements

   Authors would like to thank the comments and suggestions from Tao
   Han, Weilian Jiang.

6. References 

6.1. Normative References

   [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
             Requirement Levels", BCP 14, RFC 2119, March 1997.

   [RFC7364] T. Narten, E. Gray, et al, "Problem Statement: Overlays for
             Network Virtualization", draft-ietf-nvo3-overlay-problem-
             statement, working in progress.

   [RFC7365] Marc Lasserre, Florin Balus, et al, "Framework for DC
             Network Virtualization", draft-ietf-nvo3-framework, working
             in progress.

   [I-D.ietf-nvo3-dataplane-requirements] Nabil Bitar, Marc Lasserre, et
             al, "NVO3 Data Plane Requirements", draft-ietf-nvo3-
             dataplane-requirements, working in progress.
 

Mingui Zhang, et al       Expires June 5, 2016                 [Page 13]
INTERNET-DRAFT     YANG Data Model for NVO3 Protocols   December 3, 2015

   [RFC7348] Mahalingam, M., Dutt, D., Duda, K., Agarwal, P., Kreeger,
             L., Sridhar, T., Bursell, M., and C. Wright, "Virtual
             eXtensible Local Area Network (VXLAN): A Framework for
             Overlaying Virtualized Layer 2 Networks over Layer 3
             Networks", RFC 7348, August 2014.

   [RFC3688] Mealling, M., "The IETF XML Registry", BCP 81, RFC 3688,
             January 2004.

   [RFC6020] Bjorklund, M., Ed., "YANG - A Data Modeling Language for
             the Network Configuration Protocol (NETCONF)", RFC 6020,
             October 2010.

   [RFC6241] Enns, R., Ed., Bjorklund, M., Ed., Schoenwaelder, J., Ed.,
             and A. Bierman, Ed., "Network Configuration Protocol
             (NETCONF)", RFC 6241, June 2011.

6.2. Informative References

   [I-D.zhang-nvo3-yang-active-active] M. Zhang, J. Xia, "YANG Data
             Model for NVO3 Active Active Access", draft-zhang-nvo3-
             yang-active-active, working in progress.

   [I-D.sridharan-virtualization-nvgre] M. Sridharan, A. Greenberg, et
             al, "NVGRE: Network Virtualization using Generic Routing
             Encapsulation", draft-sridharan-virtualization-nvgre,
             working in progress.

 

Mingui Zhang, et al       Expires June 5, 2016                 [Page 14]
INTERNET-DRAFT     YANG Data Model for NVO3 Protocols   December 3, 2015

Author's Addresses

   Mingui Zhang
   Huawei Technologies
   No. 156 Beiqing Rd. Haidian District,
   Beijing 100095 
   P.R. China
        
   EMail: zhangmingui@huawei.com

   Lianshu Zheng
   Huawei Technologies
   No. 156 Beiqing Rd. Haidian District,
   Beijing 100095 
   P.R. China
        
   EMail: vero.zheng@huawei.com

   Feng Zheng
   Huawei Technologies
   No. 156 Beiqing Rd. Haidian District,
   Beijing 100095 
   P.R. China

   EMail: habby.zheng@huawei.com

   Fu Qiao
   China Mobile 

   EMail: fuqiao@chinamobile.com

Mingui Zhang, et al       Expires June 5, 2016                 [Page 15]